Level Plus. Product Accessories. Magnetostrictive Liquid-Level Sensors with Temposonics Technology

Similar documents
Level Plus. Product Accessories. Magnetostrictive Liquid-Level Sensors with Temposonics Technology

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. Accessories Catalog

Level Plus. Magnetostrictive Liquid-Level Transmitters with Temposonics Technology. Liquid-Level Transmitter Accessories Catalog

Level Plus. Liquid-Level Sensors With Temposonics Technology. Accessories Catalog

Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. Accessories for liquid level transmitters Catalog

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology

Level Plus. Liquid-Level Product Catalog. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. Document Part Number Revision E

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. C-Series Core Sensor, Models CS and CM Analog Outputs (Voltage/Current)

T E M P O S O N I C S I I I INSTALLATION

Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. LP-Series Board Replacement Operation Manual

Temposonics. Magnetostrictive, Linear-Position Sensors. G-Series Embedded Redundant Model GTE Analog (Voltage/Current) Data Sheet

Temposonics. R-Series POWERLINK. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Measuring length mm

Data Sheet. Model ER position sensor, features a versatile rod-and-cylinder design with optional dual rod ends. Interrogation Return wire.

T E M P O S O N I C S I I I INSTALLATION CAUTION! B. CONNECTORS RG Connector. D6 Connector: INTEGRAL CABLE P Integral Cable

Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR3/4 MLG Transmitter with Analog Output.

Level Plus. Magnetostrictive Liquid-Level Transmitters with Temposonics Technology

LTM IntelliGage Series Magnetostrictive Level Transmitters

Family of Water Cut Analyzers

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. R-Series Models RP and RH Profibus-DP Output.

Temposonics. User s Manual. MH-CAN Testkit. CANopen & SAE J1939. Absolute, Non-Contact Position Sensors. Document Part Number.

MTS Sensors. NEWS 2013 / 2014 Agritechnica 2013 / Hall 1, Booth E127. Position and Angle Measurement in Mobile Machines. The Measurable Difference

Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. HART Interface Manual LP Series

Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. Safety Manual LP Series. Safety Integrity Level IEC 61508

Model 675 DREXELBROOK. Shark Cage Submersible Level Transmitter DATA SHEET. Description. Features. Applications.

Temposonics. Magnetostrictive Linear Position Sensors. EE Analog Data Sheet

Product Data. Model 675 Shark Cage Submersible Level Transmitter ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

BLISS ANAND. BA-Series Magnetostrictive Level Transmitter

FTP Factory Trade-In Program

4110 HART Level Encoder

Level Plus Liquid-Level Sensors With Temposonics Technology

Digital Level Sensor. Consistent accuracy, unparalleled reliability. Answers for energy.

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

Flow Measurement SITRANS F M

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. E-Series Models EP and EL Analog and Start/Stop Outputs.

Temposonics. Magnetostrictive Linear-Position Sensors. R-Series Model RP and RH Sensors Profibus-DP Output B Product Specification

Universal IV Water Cut Meter

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level sensor Magnetostrictive, high-resolution measuring principle Models FFG-P, FFG-T, FFG-TP, FLM-H

Flow Measurement SITRANS F M

Flow Measurement SITRANS F US Clamp-on

UFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design

Gladiator Acoustic Switch Series

Series DMHF Heat Meter

Clamp-On Transit Time Ultrasonic Flow Meters

imag 4700 Series FLANGED MAGMETER

L-Dens 4X7 Series. Process Density Sensors. ::: Process instrumentation at its best

Level gauges Series LS Level indicator, switch and transmitter for liquids

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

Temposonics. Magnetostrictive Linear Position Sensors. PROGRAMMING & CONFIGURATION GBS Analog via Bluetooth. The Measurable Difference

SCADAPack Modbus multivariable transmitter

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

SC100 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

1/2 NPTM mm Nose cone fitting Ideal for clean liquids

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

LiquiDens. SensoTech. Process density meter for liquids Product description

DMTFP Portable Ultrasonic Flow Meters

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

imag 4700 Series FLANGED MAGMETER

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

LS 6600 Technical Datasheet

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

RHE27. Rack/Panel Mount Multifunction Coriolis Flow Transmitter

Flow Meters. Model B Flow Monitor. Model B2800. Flow Monitor

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

TPE 1464 Series Pressure Transducer

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

SITRANS F flowmeters SITRANS F US

Level-Lance Model 5400A

RHM160. Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications. Features. Applications. Benefits

DTM Distributed Transmitter Monitor

MMT330 Series Moisture and Temperature Transmitters for Oil

SERIES 8000-SAN PRESSURE AND LEVEL TRANSMITTERS ALL STAINLESS DESCRIPTION. OUTPUT 4-20 ma / 2-WIRE ZERO AND SPAN ADJUSTABLE

Series DMTFB wall-mount Clamp-on Transit Time Ultrasonic Flow Meters provide abundant capabilities for accurate liquid flow measurement from

Ultrasonic Heat Flow Meters

2910 Float & Tape Transmitter

Adapter system for measuring instruments with G1 hygienic connection Model process adapter

TRICOR Series TCM Coriolis Mass Flow Meters

914S. Capacitive Sanitary Pressure Transmitter. Features. 1 Datasheet 914S Capacitive Sanitary Pressure Transmitter

Flow Measurement SITRANS F C

Variable Area Flowmeter DATASHEET

NightStar. Installation, Operation, & Maintenance Instructions M /04/2016

2900 Float & Tape Transmitter

Sensors Division. Level Plus Direct Digital Access (DDA) Tank Gauge. Operation Guide and Installation Manual. P/N Revision D

SCADAPack Modbus multivariable transmitter

RHE28. Field and Wall Mount Multifunction Coriolis Flow Transmitter

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing

RHE26. Rack/Panel Mount Multifunction Coriolis Flow Transmitter

Installation and Operating Manual FM50 IOM 2-18 DRAFT

MCG 1500SFI. MCG 1500SFI Smart Flash Infrared Servo Gauge. Features. Smart Flash Infrared Servo Gauge

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

Level Measurement Continuous level measurement - Ultrasonic transmitters

914L. Capacitive Level Transmitter. Features. 1 Datasheet 914L Capacitive level transmitter for liquids.

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

DCT7088 Portable Digital Correlation Transit Time Flowmeter

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

Offering 100% dependability under pressure

Transcription:

Level Plus ostrictive Liquid-Level Sensors with Temposonics Technology SENSORS Product Accessories Floats, s, Meters, Enclosures, Indicators, Interface Terminals and Programming Document Part Number 551103 Revision E Features Variety of Styles and Sizes to Fit Most Applications Available in 316L Stainless Steel, Aluminum, Teflon, Hastelloy C and Nitrophyl Custom ing Available Applications Custody Transfer Inventory Control Bulk Storage Sanitary Process Control Markets Petroleum and Petrochemical LPG Terminals Biotech and Pharmaceutical Food and Beverage Waste and Wastewater Accessories overview offers a variety of floats to meet your application needs. Our floats come in a variety of sizes from less than 38 mm (1.5 in.) up to 178 mm (7 in.) in diameter. Float materials are available in stainless steel, Teflon, Aluminum, Hastelloy C and Nitrophyl. Offset weighted floats are also available for applications requiring ATEX approval. Product viscosity, specific, and temperature can vary widely in a process or tank gauging application. Because of these variables and others, such as tank pressure and corrosiveness, no one float can meet all requirements. Therefore, a variety of float styles are available and we will assist you in choosing the one that best meets your requirements. When choosing a float for your application, MTS recommends you choose one that has a specific of at least 0.05 less than that of the measured liquid. For interface measurement, a minimum of 0.05 specific differential is recommended between upper and lower liquids. also offers a variety of meters, housings, and calibration equipment as accessories to our transmitter range. Meters are available for analog, DDA, and Modbus outputs. For more information, please contact the applications department or go to www.mtssensors.com for more information. MTS Offers a Variety of M-Series Liquid-Level Product Accessories FM APPROVED All specifications are subject to change. Contact MTS for specifications and engineering drawings that are critical to your application. Drawings contained in this document are for reference only. Go to www.mtssensors.com for the latest support documentation.

Standard Float Options General tes: 1. Be sure that the float specific is at least 0.05 less than that of the measured liquid as a safety margin at ambient temperature. 2. For interface measurement: A minimum of 0.05 specific differential is required between the upper and lower liquids. 3. When the magnet is not shown, the magnet is positioned at the center line of float. 4. Offset weight option: A weight is installed in the float to bias, or tilt, the float installed on the transmitter tube so that the float remains in contact with the transmitter tube at all times. The option is required for installations that must conform to ATEX standards. 5. Drawings contained in this document are for reference only. Contact the factory for engineering drawings. 6. *Call for specific lead times. Typical lead time exceeds lead time of the transmitter. Standard Product Floats 0.65 251981-1 77 mm (3.01 in.) 29.3 bar (425 psi) 0.67 251981-2* 0.68 Hastelloy C 251981-3 47 mm (1.85 in.) dia. 0.71 Hastelloy C 251981-4* 0.48 251387-1 57 mm (2.22 in.) 22.4 bar (325 psi) 59 mm (2.32 in.) dia. 0.48 251387-2* 36 mm (1.4 in.) 8.6 bar (125 psi) 0.74 200938-1 41 mm (1.61 in.) dia. 0.74 200938-2* 50 mm (1.95 in.) 51.7 bar (750 psi) 0.74 252354* 55 mm (2.14 in.) dia. 50 mm (1.96 in.) 54 mm (2.11 in.) 4 bar (60 psi) 0.6 201605-2 47 mm (1.83 in.) dia. 45 mm (1.75 in.) dia. (0.70 in.) Min. ID 0.45 Aluminum 201693-1 79 mm (3.1 in.) Max. 67 mm (2.60 in.) 29.3 bar (425 psi) 0.45 Aluminum 201693-2 2

Standard Float Options Standard Product Floats 91 mm (3.57 in.) 29.3 bar (425 psi) 89 mm (3.5 in.) dia. 0.43 251469-1 0.45 251469-2* Low-liftoff FLOAT 15 mm (0.57 in.) Ref 39 mm (1.52 in.) 26 mm (1 in.) 76 mm (3 in.) (0.7 in.) 101 mm I.D. min. (3.95 in.) O.D. 38 mm (1.5 in.) 8.6 bar (125 psi) 0.65 252228-3* Standard Interface Floats 77 mm (3.01 in.) 29.3 bar (425 psi) 0.90-251982-1 251982-2* 251982-3 Hastelloy C 47 mm (1.85 in.) dia. 251982-4* 251983-1 77 mm (3.01 in.) 29.3 bar (425 psi) 1.03-1.10 251983-2* 251983-3* Hastelloy C 47 mm (1.85 in.) dia. 251983-4* 27 mm (1.06 in.) 31 mm (1.22 in.) 4 bar (60 psi) 0.85-0.9 201606-2 47 mm (1.83 in.) dia. 3

Sanitary Float Options General tes (for sanitary applications): 1. Be sure that the float specific is at least 0.05 less than that of the measured liquid as a safety margin at ambient temperature. 2. For interface measurement: A minimum of 0.05 specific differential is required between the upper and lower liquids. 3. Sanitary polish is available for stainless-steel floats up to 200 Grit/Ra 25. 4. Electropolish is available for stainless-steel floats up to 240 Grit/Ra 15. 5. When the magnet is not shown, the magnet is positioned at the center line of float. 6. Offset weight option: A weight is installed in the float to bias, or tilt, the float installed on the transmitter tube so that the float remains in contact with the transmitter tube at all times. The option is required for installations that must conform to ATEX standards. 7. Drawings contained in this document are for reference only. Contact the factory for engineering drawings. 8. *Call for specific lead times. Typical lead time exceeds lead time of the transmitter. tes: 1. Float meets 3A Sanitary specifications. 2. Use this float with all Sanitary transmitter wells as other floats may enter the inactive zone when the tank is emptied. Sanitary Floats 108 mm (4.25 in.) 89 mm (3.5 in.) 47 mm (1.85 in.) dia. Centerline of magnet 10.3 bar (150 psi) 0.66 200 Grit/ Ra 25 μm (0.625 μm) 240 Grit/ Ra 15 μm (0.375 μm) 401513-1 401513-2* 401513-3* 401513-4* tes: 1. Float meets 3A Sanitary specifications. 2. Float may enter the inactive zone when used with 3A Sanitary transmitter wells. 75 mm (2.95 in.) 60 mm (2.34 in.) dia. C L 38 mm (1.5 in.) 64 mm (2.5 in.) C L of magnet with Offset 22.4 bar (325 psi) 22.4 bar (325 psi) 0.63 0.63 200 Grit/ Ra 25 μm (0.625 μm) 240 Grit/ Ra 15 μm (0.375 μm) 200 Grit/ Ra 25 μm (0.625 μm) 240 Grit/ Ra 15 200931-1* 200931-2* 200931-3* 200931-4* 200931-5* 200931-6* 200931-7* 200931-8* 4

Sanitary Float Options te: Use this float with all Sanitary transmitter wells as other floats may enter the inactive zone when the tank is emptied. Sanitary FLOATs continued 51 mm (2 in.) dia. Over weld bead 25 mm (.98 in.) 48 mm (1.9 in.) 102 mm (4.02 in.) 8.6 bar (125 psi) 048 240 Grit/ Ra 15 μm (0.375 μm ) 252228-1* 41 mm (1.6 in.) (.7 in.) I.D. Min. 92 mm (3.6 in.) dia. tes: 1. Float meets clean-in-place and drain-in-place applications. 2. Float may enter the inactive zone. Consult factory about viability of usage. 51 mm (2 in.) O.D. Over weld bead 25 mm (.98 in.) 251234-1* 50 mm (1.96 in.) 22.4 bar (325 psi) 0.74 240 Grit/ Ra 25 μm (0.625 μm ) 251234-2* (0.7 in.) Min I.D. tes: 1. Float meets 3A Sanitary specifications. 2. Float meets clean-in-place and drain-in-place applications. 3. Float may enter the inactive zone. Consult factory about viability of usage. R.157 (4) Min. position CL 56 mm (2.21 in.) 23 mm (.9 in.) dia. 80 mm (3.15 in.) dia. 73 mm (2.85 in.) dia. 8.6 bar (125 psi) 0.83-0.86 240 Grit/ Ra 15 μm (0.375 μm ) 560564-2* 5

Teflon Float Options General tes: 1. Be sure that the float specific is at least 0.05 less than that of the measured liquid as a safety margin at ambient temperature. 2. For interface measurement: A minimum of 0.05 specific differential is required between the upper and lower liquids. 3. When the magnet is not shown, the magnet is positioned at the center line of float. 4. Offset weight option: A weight is installed in the float to bias, or tilt, the float installed on the transmitter tube so that the float remains in contact with the transmitter tube at all times. The option is required for installations that must conform to ATEX standards. 5. Drawings contained in this document are for reference only. Contact the factory for engineering drawings. 6. *Call for specific lead times. Typical lead time exceeds lead time of the transmitter. Teflon Floats 9 mm (0.35 9 mmin.) (0.35 in.) 76 mm 76 (3 mm in.) (3 in.) 18 (0.7 mmin.) dia. Centerline Centerline of of 1.7 bar (25 psi) 38 C (100 F) 0.86 Teflon 201109* 0.90-0.95 Teflon 251115* 61 mm (2.38 61 mm in.) dia. (2.38 in.) dia. (0.7 in.) 18 dia. mm 1.04-1.11 Teflon 251116* 135 mm (5.3 in.) 135 mm (5.3 in.) 67 mm (2.65 in.) 67 mm (2.65 in.) Centerline of Centerline of 1.7 bar (25 psi) 38 C (100 F) 0.86 Teflon 251939* 49 mm (1.9 in.) dia. 49 mm (1.9 in.) dia. (0.7 in.) (0.7 in.) 28 mm 28 mm (1.1 in.) dia. (1.1 in.) dia. Centerline Centerline of of 0.9-0.95 Teflon 251119* 115 mm 115 mm (4.5 in.) (4.5 in.) 1.7 bar (25 psi) 38 C (100 F) 115 mm 115 mm (4.5 in.) dia. (4.5 in.) dia. 1.04-1.11 Teflon 251120* 6

Nitrophyl Float Options General tes: 1. Be sure that the float specific is at least 0.05 less than that of the measured liquid as a safety margin at ambient temperature. 2. For interface measurement: A minimum of 0.05 specific differential is required between the upper and lower liquids. 3. When the magnet is not shown, the magnet is positioned at the center line of float. 4. Offset weight option: A weight is installed in the float to bias, or tilt, the float installed on the transmitter tube so that the float remains in contact with the transmitter tube at all times. The option is required for installations that must conform to ATEX standards. 5. Drawings contained in this document are for reference only. Contact the factory for engineering drawings. 6. *Call for specific lead times. Typical lead time exceeds lead time of the transmitter. Nitrophyl Floats 0.40 201643-1 Nitrophyl 0.45 201643-2 (.07 in.) dia. 17.2 bar (250 psi) 104 C (220 F) 0.80-0.86 Nitrophyl 201649-1 201649-2 C L 76 mm (3 in.) 31 mm (1.2 in.) dia. Added weight for interface floats 0.91 - Nitrophyl 201650-1 201650-2 Stainless cover Stainless float post 168 mm (6.61 in.) C L 152 mm (5.99 in.) 17.2 bar (250 psi) 104 C (220 F) 0.90 - Nitrophyl 252999* 30 mm (1.19 in.) 153 mm I.D. (6.00 in.) dia. Nitrophyl base 7

Long-gauge Float Options General tes: 1. Be sure that the float specific is at least 0.05 less than that of the measured liquid as a safety margin at ambient temperature. 2. For interface measurement: A minimum of 0.05 specific differential is required between the upper and lower liquids. 3. When the magnet is not shown, the magnet is positioned at the center line of float. 4. Offset weight option: A weight is installed in the float to bias, or tilt, the float installed on the transmitter tube so that the float remains in contact with the transmitter tube at all times. The option is required for installations that must conform to ATEX standards. 5. Drawings contained in this document are for reference only. Contact the factory for engineering drawings. 6. *Call for specific lead times. Typical lead time exceeds lead time of the transmitter. Long-gauge Floats 92 mm (3.6 in.) dia. 28 mm (1.1 in.) dia. 0.54 251223-1 0.65 Hastelloy C 251223-3* 88 mm (3.44 in.) C L 44 mm (1.72 in.) 29.3 bar (425 psi) 0.90-1.03-1.10 251224-1 Hastelloy C 251224-3* 251225-1* Hastelloy C 251225-3* C L 92 mm (3.6 in.) dia. 28 mm (1.1 in.) dia. 0.54 252961-1 252961-2* 76 mm (3 in.) 88 mm (3.44 in.) 29.3 bar (425 psi) 0.90-252962-1 252962-2* 1.03-1.10 252963-1* 252963-2* 0.44 250709-1* 0.52 Hastelloy C 250709-3* 127 mm (4.98 in.) CL 37.9 bar (550 psi) 0.90-250714-1* Hastelloy C 250714-3* 63 mm (2.49 in.) 28 mm (1.1 in.) dia. 130 mm (5.11 in.) 1.03-1.10 250855-1* Hastelloy C 250855-3* 8

6.95 in. (00.0 mm) Long-gauge Float Options Long-gauge Floats (Continued) 0.44 201248-1 0.44 201248-2* 127 mm (4.98 in.) 116 mm (4.55 in.) C L 37.9 bar (550 psi) 0.90-252959-1 252959-2* 28 mm (1.1 in.) 130 mm (5.11 in.) 1.03-1.10 252960-1* 252960-2* 0.44 251426-1* 251426-2* 178 mm (7 in.) 178 mm (7 in.) 48 mm (1.9 in.) I.D. 17.2 bar (250 psi) 0.47 0.90 - Hastelloy C-22 Hastelloy C-22 251426-3* 251426-4* 251427-1* 251427-2* 251427-3* 251427-4* 1.03-1.10 251428-1* 251428-2* 201232-1 0.66 28 mm (1.1 in.) dia. 201232-2* 127 mm (5.01 in.) 22.4 bar (325 psi) 0.70 Hastelloy C 201232-3* 201232-4* 70 mm (2.76 in.) max. dia. 0.92-201233-1* 201233-2* 9

Process Meters and Enclosure Options Analog Process Meters LED Display Universal Analog Process Meter Precision Digital PD6000-6R0 6 Digit LED display Input: Analog 4-20 ma Output: ne 110 VAC Input Power 32 point linearization Includes 24 Vdc transmitter supply : Standard 1/8 in. DIN, high impact plastic, NEMA Type 4X front panel LED Display Universal Analog Process Meter (2 Relays) Precision Digital PD6000-6R2 6 Digit LED display Input: Analog 4-20 ma Output: 2 relays 110 VAC Input Power 32 point linearization Includes 24 Vdc transmitter supply : Standard 1/8 in. DIN, high impact plastic, NEMA Type 4X front panel LED Display Universal Analog Process Meter (4 Relays) Precision Digital PD6000-6R4 6 Digit LED display Input: Analog 4-20 ma Output: 4 relays 110 VAC Input Power 32 point linearization Includes 24 Vdc transmitter supply : Standard 1/8 in. DIN, high impact plastic, NEMA Type 4X front panel LED Display Universal Analog Process Meter (2 Relays, 4-20 ma) Precision Digital PD6000-6R5 6 Digit LED display Input: Analog 4-20 ma Output: 4-20 ma and 2 relays 110 VAC Input Power 32 point linearization Includes 24 Vdc transmitter supply : Standard 1/8 in. DIN, high impact plastic, NEMA Type 4X front panel 380071 380072 380073 380095 XP Loop Powered Analog Meter Loop Powered on 4-20 ma output Displays in Percentage Only Embedded in XP Housing XP: Class I, II, III; Division 1; Groups B-G IS: Class I, II, III; Division 1; Groups A-G 380062 Loop Powered Analog Meter F070-A-HG-PL-X1-ZB Loop Powered on 4-20 ma output Displays loop current, engineering units, and/or value Selectable on screen engineering units IP 67 / NEMA Type 4X Intrinsically Safe, backlight 380088 10

Process Meters and Enclosure Options ANALOG PROCE METERS (CONTINUED) Multi-Channel Consolidating Analog Process Meter Precision Digital PD941-8K9-15 Input: 4 Analog 4-20 ma Output: 4 Analog 4-20 ma, 9 relays 110 VAC Input Power 32 point linearization 380089 MODBUS PROCE METERS Multivariable Modbus Process Meter Display levels in feet, inches, and 16ths of an inch Scrolling Display of Product, Interface, Temperature, or combination Input: RS485 Modbus RTU Output: 2 Form A relays and 4-20 ma 110 VAC Input Power 16 point linearization Includes 24 Vdc transmitter supply : Standard 1/8 in. DIN, high impact plastic, NEMA Type 4X front panel 380086 Single Variable Modbus Process Meter Precision Digital PD865-6R5-16 6 Digit Display in Decimal Format Display 1 process variable without interrupting Master/Slave communication Input: RS485 Modbus RTU Output: 2 Form A relays and 4-20 ma 110 VAC Input Power 16 point linearization Includes 24 Vdc transmitter supply : Standard 1/8 in. DIN, high impact plastic, NEMA Type 4X front panel 380094 11

Process Meters and Enclosure Options Process Meter Enclosures XP Enclosures Display 380086 or 380094 Display 380088 XP Enclosures are available for most process meters, please contact factory for more information. 561452 561453 NEMA Enclosures Single NEMA 4X (PDA 2811) Dual NEMA 4X (PDA 2302) NEMA Enclosures are available for most process meters, please contact factory for more information. 401150 401151 Modbus Terminals LCD Modbus Terminal Displays up to 4 tanks (2 levels, temp, volume) Displays up to 8 tanks (2 levels, temp) Displays levels in ft., in, and 16ths in. Input: Up to 8 Modbus transmitters Output: Modbus Mounted in NEMA 4 box Class 1 Div. 2 Includes Power Supply Calibrate from Screen 280494-X Touchscreen Modbus Terminal Displays up to 16 tanks (2 levels, temp, volume) Displays levels in ft., in, and 16ths in. Input: up to 16 Modbus transmitters Output: Modbus Pictorial display of tanks Touchscreen Mounted in NEMA 4 box Class 1 Div. 2 Includes Power Supply Calibrate from Screen 280508 12

Programming and Hardware Options Programming Accessories HT100 Hand Held Terminal M-Series Model MG Transmitter with DDA output Remote setup, troubleshooting, and maintenance 251259 Setup Software Hardware M-Series Model MG PC setup software on CD Includes RS-485 to RS-232 adapter, part no. 380077 M-Series Model MG PC setup software on CD M-Series Model MR PC setup software on CD Includes HART adapter, part no. 380068 M-Series Model MR PC setup software on CD HART to RS-232 adapter (SMAR H1-311) RS-485 to RS-232 adapter converter (B & B Electronics) Hex Bushing 2 in. MNPT x 3/4 in. FNPT Hex Bushing 2 in. FNPT x 4 in. MNPT Hex Bushing 1 in. FNPT x 2 in. MNPT 625051 625052 252273-1 252273-2 380068 380077 561440 561441 561448 13

and Assembly Options and weight assemblies 51 mm (2 in.) 76 mm (3 in.) 150 lb. Pull For LDF long transmitter and M-Series transmitters. (Top ring must be removed before installation) 560604 51 mm (2 in.) Standard 11 lb. For M-Series transmitters 401059 127 mm (5 in.) A 193 mm (7.5 in.) dia. 165 mm (6.5 in.) dia. 84 mm (3.3 in.) 3 mm (.13 in.) 16 mm (.63 in.) Low Liftoff 11 lb. Assembly Use with float, part no. 252999 402364 A Section A-A 89 mm (3.5 in.) dia. 32 mm (1.25 in.) dia. (2X) 115 mm (4.5 in.) 1.3 X 45 Chamfer 37 mm (1.44 in.) Narrow 11 lb. Use with M-Series transmitters 402647 64 mm (2.5 in.) 21 mm (.81 in.) dia. 14

15

Document MTS, Temposonics and Level Plus are registered trademarks of MTS Systems Corporation. All other trademarks are the property of their respective owners. Printed in USA. Copyright 2011 MTS Systems Corporation. All Rights Reserved in all media. All specifications are subject to change. Contact MTS for specifications and engineering drawings that are critical to your application. Drawings contained in this document are for reference only. Go to http://www.mtssensors.com for the latest support documentation and related media. SENSORS MTS Systems Corporation Sensors Division 3001 Sheldon Drive Cary, rth Carolina 27513, USA Tel.: +1-800-633-7609 Fax: +1-919-677-2343 +1-800-498-4442 e-mail: sensorsinfo@mts.com http://www.mtssensors.com MTS Sensor Technologie GmbH & Co. KG Auf dem Schüffel 9 D - 58513 Lüdenscheid, Germany Tel.: +49-2351-9587-0 Fax: +49-2351-56491 e-mail: info@mtssensor.de http://www.mtssensor.de Technology Corporation 737 Aihara-cho, Machida-shi Tokyo 194-0211, Japan Tel.: +81-42-775-3838 Fax: +81-42-775-5516 e-mail: info@mtssensor.co.jp http://www.mtssensor.co.jp