A Radiometry Tolerant Method for Direct 3D/2D Registration of Computed Tomography Data to X-ray Images

Similar documents
Comparison of Different Metrics for Appearance-model-based 2D/3D-registration with X-ray Images

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

Evaluation of Spectrum Mismatching using Spectrum Binning Approach for Statistical Polychromatic Reconstruction in CT

CLASS HOURS: 4 CREDIT HOURS: 4 LABORATORY HOURS: 0

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago

Is deformable image registration a solved problem?

3D Voxel-Based Volumetric Image Registration with Volume-View Guidance

Contrast Enhancement with Dual Energy CT for the Assessment of Atherosclerosis

Registration of 2D to 3D Joint Images Using Phase-Based Mutual Information

Ch. 4 Physical Principles of CT

Metal Artifact Reduction CT Techniques. Tobias Dietrich University Hospital Balgrist University of Zurich Switzerland

Utilizing Salient Region Features for 3D Multi-Modality Medical Image Registration

2D-3D Registration using Gradient-based MI for Image Guided Surgery Systems

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

Radiology. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

DUAL energy X-ray radiography [1] can be used to separate

3D Registration based on Normalized Mutual Information

Optimization of scanner parameters for dual energy micro-ct

Suitability of a new alignment correction method for industrial CT

A Study of Medical Image Analysis System

An Automated Image-based Method for Multi-Leaf Collimator Positioning Verification in Intensity Modulated Radiation Therapy

Support Vector Machine Density Estimator as a Generalized Parzen Windows Estimator for Mutual Information Based Image Registration

Spectral analysis of non-stationary CT noise

Gradient-Based Differential Approach for Patient Motion Compensation in 2D/3D Overlay

Artifact Mitigation in High Energy CT via Monte Carlo Simulation

Spiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA

Hybrid Spline-based Multimodal Registration using a Local Measure for Mutual Information

A New Method for CT to Fluoroscope Registration Based on Unscented Kalman Filter

SPECT reconstruction

Effects of the difference in tube voltage of the CT scanner on. dose calculation

Automated Image Analysis Software for Quality Assurance of a Radiotherapy CT Simulator

DUAL energy CT (DECT) is a modality where one and. Empirical Dual Energy Calibration (EDEC) for Cone-Beam Computed Tomography

Scatter Correction Methods in Dimensional CT

Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition

Joint CI-JAI advanced accelerator lecture series Imaging and detectors for medical physics Lecture 1: Medical imaging

Automated Quality Assurance for Image-Guided Radiation Therapy

8/3/2016. Image Guidance Technologies. Introduction. Outline

Rigid and Deformable Vasculature-to-Image Registration : a Hierarchical Approach

Annales UMCS Informatica AI 1 (2003) UMCS. Registration of CT and MRI brain images. Karol Kuczyński, Paweł Mikołajczak

Reconstruction from Projections

Basics of treatment planning II

GPU implementation for rapid iterative image reconstruction algorithm

Digital phantoms for the evaluation of a software used for an automatic analysis of the Winston-Lutz test in image guided radiation therapy

TomoTherapy Related Projects. An image guidance alternative on Tomo Low dose MVCT reconstruction Patient Quality Assurance using Sinogram

Phase-Contrast Imaging and Tomography at 60 kev using a Conventional X-ray Tube

Superiorized polyenergetic reconstruction algorithm for reduction of metal artifacts in CT images

Mutual information based CT registration of the lung at exhale and inhale breathing states using thin-plate splines

Assessing Accuracy Factors in Deformable 2D/3D Medical Image Registration Using a Statistical Pelvis Model

A simple method to test geometrical reliability of digital reconstructed radiograph (DRR)

Modeling and preoperative planning for kidney surgery

Reduction of Metal Artifacts in Computed Tomographies for the Planning and Simulation of Radiation Therapy

Energy resolved X-ray diffraction Cl. J.Kosanetzky, G.Harding, U.Neitzel

Some reference material

Simulation of Mammograms & Tomosynthesis imaging with Cone Beam Breast CT images

Introduction to Biomedical Imaging

FAST KVP-SWITCHING DUAL ENERGY CT FOR PET ATTENUATION CORRECTION

An Acquisition Geometry-Independent Calibration Tool for Industrial Computed Tomography

MRI Visualisation by Digitally Reconstructed Radiographs

CT Systems and their standards

Coupled Bayesian Framework for Dual Energy Image Registration

Entropy Based, Multiple Portal to 3DCT Registration for Prostate Radiotherapy Using Iteratively Estimated Segmentation

Deformable Registration Using Scale Space Keypoints

Determination of rotations in three dimensions using two-dimensional portal image registration

Reproducibility of interactive registration of 3D CT and MR pediatric treatment planning head images

Automatic 3D-to-2D registration for CT and dual-energy digital radiography for calcification detection

Chapter 3 Set Redundancy in Magnetic Resonance Brain Images

Mech. Engineering, Comp. Science, and Rad. Oncology Departments. Schools of Engineering and Medicine, Bio-X Program, Stanford University

Improvement and Evaluation of a Time-of-Flight-based Patient Positioning System

GPU applications in Cancer Radiation Therapy at UCSD. Steve Jiang, UCSD Radiation Oncology Amit Majumdar, SDSC Dongju (DJ) Choi, SDSC

Multi-Modal Volume Registration Using Joint Intensity Distributions

Financial disclosure. Onboard imaging modality for IGRT

Depth-Layer-Based Patient Motion Compensation for the Overlay of 3D Volumes onto X-Ray Sequences

Combining Analytical and Monte Carlo Modelling for Industrial Radiology

2D/3D Registration Based on Volume Gradients

7/31/2011. Learning Objective. Video Positioning. 3D Surface Imaging by VisionRT

Projection and Reconstruction-Based Noise Filtering Methods in Cone Beam CT

maximum likelihood estimates. The performance of

Multimodality image integration for radiotherapy treatment, an easy approach

Helical 4D CT pitch management for the Brilliance CT Big Bore in clinical practice

Unmatched Projector/Backprojector Pairs in an Iterative Reconstruction Algorithm

Image Acquisition Systems

MEDICAL IMAGE ANALYSIS

Classification of Subject Motion for Improved Reconstruction of Dynamic Magnetic Resonance Imaging

Combination of Markerless Surrogates for Motion Estimation in Radiation Therapy

Mathematical methods and simulations tools useful in medical radiation physics

An Investigation of a Model of Percentage Depth Dose for Irregularly Shaped Fields

2D Rigid Registration of MR Scans using the 1d Binary Projections

Computed tomography (Item No.: P )

CT Protocol Review: Practical Tips for the Imaging Physicist Physicist

Arion: a realistic projection simulator for optimizing laboratory and industrial micro-ct

Image Registration. Prof. Dr. Lucas Ferrari de Oliveira UFPR Informatics Department

Scatter Correction for Dual source Cone beam CT Using the Pre patient Grid. Yingxuan Chen. Graduate Program in Medical Physics Duke University

2D/3D Image Registration on the GPU

S. Guru Prasad, Ph.D., DABR

HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS

Separate CT-Reconstruction for Orientation and Position Adaptive Wavelet Denoising

A Weighted Least Squares PET Image Reconstruction Method Using Iterative Coordinate Descent Algorithms

8/7/2017. Disclosures. MECT Systems Overview and Quantitative Opportunities. Overview. Computed Tomography (CT) CT Numbers. Polyenergetic Acquisition

Markerless Real-Time Target Region Tracking: Application to Frameless Stereotactic Radiosurgery

Medical Image Analysis

Transcription:

A Radiometry Tolerant Method for Direct 3D/2D Registration of Computed Tomography Data to X-ray Images Transfer Function Independent Registration Boris Peter Selby 1, Georgios Sakas 2, Stefan Walter 1, Wolfgang-Dieter Groch 3, Uwe Stilla 4 1 MedCom GmbH, Darmstadt 2 Cognitive Computing and Medical Imaging, Fraunhofer IGD Darmstadt 3 Fachbereich Informatik, University of Applied Sciences Darmstadt 4 Photogrammetry and Remote Sensing, Technische Universitaet Muenchen pselby@medcom-online.de Abstract. As exact dose delivery is essential for radiological cancer treatment, image-guided radiotherapy (IGRT) methods are used to estimate corrections of the tumor alignment. This is often done through comparison of a computed tomography (CT) to the patient alignment visible in digital radiography images (DRs) acquired from within the treatment device. Digitally reconstructed radiography images (DRRs) computed from the CT are then geometrically registered to the DRs. A problem is that radiometric properties of DRs and DRRs can vary profoundly. If a registration algorithm does not use volumetric CT data directly it is unable to regard deviations of the physical image formation to the simulated image formation. We present a novel method allowing direct DR to CT registration. It is designed to be radiometry tolerant by adapting the simulated X-ray transfer function to observed DR intensities. This is done by solving an overdetermined system of equations given by the histograms along rays through the voxel matrix of the CT. Remaining errors serve as measure for the image dissimilarity, thus minimization in 6 degrees of freedom (DOF) gives the transformation between the images. Thereby higher radiometric tolerance can be achieved, as misalignments can be identified even if DR images are acquired with inappropriate radiation parameters. 1 Introduction and related Work By registration of preoperative and intra operative data the misalignment of a radiation treatment target can be computed. Most approaches perform 2D-3D registration of CT to DR images by creating DRRs through projection of the CT and subsequent similarity maximization between DRRs and DRs [1, 2]. A problem is that radiometric properties of reconstructed DRRs often are totally different from the acquired DRs, as the physical image formation process can

118 Selby et al. hardly be modeled due to complicated statistical properties of photon-matter interactions (i.e. photoelectric absorption, Rayleigh scattering, etc.) [3]. E.g. [4] and [5] among others propose Mutual Information (MI) as a robust similarity measure for multi-modal 2D-2D registration, but in the case of DR to CT registration MI is not able to incorporate 3D information from the CT and performance depends mainly on the implementation of the CT projection process. In [6] an approach is described that adapts CT data to the used X-ray energy to increase radiometric independency. Whilst this method is suitable for some cases, it is strongly limited as only a single free parameter (the X-ray kilovoltage peak) is adapted during ray-tracing, instead of regarding possible variations for each attenuation value. In this contribution a new Transfer Function Independent Registration (TFIR) approach is presented, reducing dependency of the 2D-3D registration from radiometric properties. The image formation is modeled and Least-Squares Fit is used to adapt it by comparison of DR intensities to rays through the CT. A similarity measure is derived from remaining errors between observed and simulated intensities. Results of our approach are compared to MI based registration. 2 Materials and Methods Our approach employs the Least-Squares method, based on a functional model of the X-ray image formation process. 2.1 The TFIR Algorithm In Fig. 1 we give an overview over the complete 3D-2D registration algorithm. Assuming a certain geometric alignment for the patient, modeled by the CT, Fig. 1. The proposed 3D-2D registration algorithm, consisting of an optimization of the X-ray transfer function for image formation and the optimization of the geometric transformation in 6 DOF.

3D/2D Registration of CT to X-ray 119 one or more DRR images are created (i.e. one per DR image), employing an X- ray transfer function, roughly emulating physical image formation. The resulting intensities are compared to the observed intensities from the DR(s). The transfer function is adapted using a constrained Least-Squares Fit. The calculation bases on an overdetermined linear system with high redundancy, and minimization of the remaining errors with the 6 parameters of rigid transformation of the patient leads to a corrected alignment. 2.2 Radiometric Optimization First a simplified model of mono-energetic X-ray image formation based on the Lambert-Beer s Law is linearized. The photon fluence transmitted through a material is estimated by (1) I tr = I 0 exp ( s 0 ) µ(η)dη where I 0 is the photon fluence that would be measured without any attenuation, s is the total length of the ray s path through matter and µ is the absorption coefficient at position η on the path. However, grey values G represent absorbed photons instead of transmitted photons in digital X-ray images so that G = I 0 I tr. We normalize pixel intensities G to a range between 0 and 1 and contribute to the fact that absorption values are represented in a discrete raster. Equation 2 then gives the grey value for a ray with N s equal sized steps through the CT volume ( ) N s G = 1 exp s µ(i) (2) Equation 3 shows linearized and simplified eq. 2 to obtain an observation b from a grey value G b = ln(1 G) N s = µ(i) (3) s Selected sets of pixels in the X-ray images are regarded as observations. According to the linearized model they are expressed as sums over the histograms of the respective rays through the CT. The equations for the observed intensities are ˆb1 = b 1 + ˆr = ˆx 1 h 11 µ 1 + ˆx 2 h 12 µ 2 + + ˆx u h 1u µ u = f 1 (ˆx) ˆb2 = b 2 + ˆr = ˆx 1 h 21 µ 1 + ˆx 2 h 22 µ 2 + + ˆx u h 2u µ u = f 2 (ˆx). ˆbn = b n + ˆr = ˆx 1 h n1 µ 1 + ˆx 2 h n2 µ 2 + + ˆx u h nu µ u = f n (ˆx) where n corresponds to the number of observations b in the DR image (and correctedobservationsˆb), ˆr aretheresiduals, i.e.theobservationerrors, uequalsthe quantity of attenuation coefficients µ and h gives the occurrence of a certain attenuation coefficient on the respective ray through the CT (from the histograms of n different rays). ˆx are unknown factors to the attenuation values. i=1 i=1 (1) (4)

120 Selby et al. Wesolveforfactors ˆxwhichmodifytheattenuationsandadapttheCTtransfer function to obtain observed intensities b. As negative values of ˆx (negative attenuations) do not make physical sense, the solutions are constrained to ˆx 0 with i = 1...u. Non Negative Linear Least-Squares algorithm of Lawson & Hanson [7] and Singular Value Decomposition are used to solve for for the constrained ˆx. 2.3 Registration Remaining errors ˆr are computed by comparing the simulated intensities computed with optimized transfer function to observed DR intensities. Downhill simplex minimization of the root mean square (RMS) of residuals ˆr gives the six transformations of the rigid registration of the CT to the X-ray image(s). In each step of the optimization process, the radiometric optimization is repeated and a new set of residuals is generated from (4). 3 Results & Discussion Our approach was tested using different high resolution CT scans (2 anatomical phantoms of human heads and 1 human pelvis with approximately 1mm voxel diagonal) and X-ray images acquired in a treatment machine. Image acquisitions with different X-ray tube settings were performed, including kilo-voltage peak settings ranging from 40 to 140kVp and tube current settings ranging from 80 to 640mA. In Fig. 2 an X-ray image with a low kvp setting is shown (a). In the center the DRR can be seen that was rendered with the initial X-ray transfer function. With respect to the X-ray image it varies profoundly in its radiometric (a) X-ray image (b) Original DRR (c) Adapted DRR Fig.2. X-ray image of an anatomical head phantom acquired with the X-ray tube at 40kVp, 100mA and 100ms (a); original DRR image (b); DRR image after several automatic adaptations of the attenuation coefficients during the registration process (c).

3D/2D Registration of CT to X-ray 121 properties. In contrast, the DRR on the right, which was generated with the automatically adapted transfer function, looks similar to the DR. Numerous comparisons of alignment computations using mutual information (MI) versus the proposed TFIR approach were performed. In most cases the target registration accuracy of TFIR was similar to the MI approach (approx. 1 2 DRR Resolution). Tests with DRs of low Signal to Noise Ratio and images containing features (e.g. head fixation device or metallic markers) not visible in the CT show that TFIR is more intolerant regarding those types of image degradation. Additionally, the computation time of TFIR is increased by approximately factor 8 with respect to the MI approach. Nevertheless, results also show that if the X-ray tube voltage is in a very high or low range, automatic transfer function optimization during registration can help to increase registration reliability. Providing higher tolerance against low kvp settings, the TFIR approach could allow reducing the dose delivered to the patient during the X-ray imaging in IGRT. References 1. Birkfellner W, Wirth J, Burgstaller W, et al. A faster method for 3D/2D medical image registration: A simulation study. Int J Radiat Oncol Biol Phys. 2003;48:2665 79. 2. Russakoff DB, Rohlfing T, Mori K, et al. Fast generation of digitally reconstructed radiographs using attenuation fields with application to 2D-3D image registration. IEEE Trans Med Imaging. 2005;24(11):1441 54. 3. Seibert JA. X-Ray imaging physics for nuclear medicine technologists: Part1: Basic principles of X-Ray production. J Nucl Med Technol. 2004;32(3):139 47. 4. Maes F, Collignon A, Vandermeulen D, et al. Multimodality image registration by maximization of mutual information. IEEE Trans Med Imaging. 1997;16(2):187 98. 5. Pluim J, Maintz J, Viergever M. Mutual information based registration of medical images: A survey. IEEE Trans Med Imaging. 2003;22(8):986 1004. 6. Selby BP, Sakas G, Stilla U, et al. Reconstruction and registration of multispectral x-ray images for reliable alignment correction in radiation treatment devices. Proc SPIE. 2008;6914:2U.1 2U.9. 7. Lawson CL, Hanson RJ. Solving Least Squares Problems. Prentice-Hall, Englewood Cliffs, NJ; 1974.