Super Manual Fiber Amplifier Adjuster type standard that is the culmination of true ease and simplicity Features Self-explanatory LED bar displays of light levels The previous manual type used the stability and incident level indicators to display the light level change, which was difficult to understand at a glance. The uses the LED bars to display the light level, ensuring the light level change at a glance. Same "Wire-saving" Connector as EX-DA-N OMR's original wiring-saving connector, which was inherited from the digital fiber amplifier EX-DA-N, allows connection of up to units. Gang-mount up to Amplifiers indicator Approx. 20% or lower Approx. 10% or lower Unstable level Approx. -10% or higher Approx. -20% or higher Master connector Optical communications Power supply pin Slave connector * The vertical movement of the LED light level and operation display shows the light level at a glance. Conventional model A-1
Features Reduced wiring and space requirements for power lines Example for 5 Amplifiers Series series Example for 5 Amplifiers Less space required. No relay connectors required. Output lines separate from power 7 lines Power supplied from master amplifier through master connector to slave amplifiers. Optical Communications to Prevent Mutual Interference Optical communication between amplifiers prevents mutual interference. Up to 5 fiber heads can be installed closely, except #F. Five previous amplifiers Reduced Wiring and Space Requirements for Power Lines Output lines and power lines 15 lines Power and output lines required for each amplifier. Optical commu nications Up to 5 Amplifiers Relay connectors Same Sensing Distance as Previous Longdistance Models 200 mm Reflective Models Dimensions and Designs Inherited from the EX-DA-N Digital Fiber Amplifier Standard: EX-A 100mm Long-distance: EX-H Standard model 200mm Digital Fiber Amplifier EX-DA-N Standard-feature delay timer 50mm 100mm 150mm 200mm Sensing distance Note: The above characteristics are ensured with the E2-D11L Reflective Sensor (long-distance model). * The Series does not have a long-distance model. Approximately Seven Times the Detection Accuracy Applied Fiber: E2-TP (screen fiber) set at 100 mm. EX- A1 1 (previous model) Minimum detection object: 2.0 mm dia. 0. mm dia. 10mm Same 10-mm width as the EX-DA-N Digital Fiber Amplifier (Previously 12 mm) Super manual Amplifier Non-removable hinged co 8-turn adjustment knob for precise adjustment (with indicator) Easy-to-see indicator Same shape as the EX-DA-N Digital Fiber Amplifier Applied Fiber: E2-T (screen fiber) set at 100 mm. EX-A11 (previous model) Minimum detection object: 7 times 2.0 mm dia. 0. mm dia. Addition of high-speed type and waterproof type to the series A-2 Advanced Photoelectric Sensors
Ordering Information Amplifier Units Pre-wired Item Shape Control output Model NPN output PNP output Standard models 11 1 High-speed detection 11F 1F Mark-detecting models G11 G1 / output Water-resistant models 11V 1V Connector type Item Shape Applicable Connector (order separately) Control output NPN output Model PNP output Standard models Master Slave EX-CN11 EX-CN12 / output 6 8 Water-resistant models (M8 Connector) XSF-M21-0#-A XSF-M22-0#-A 1V V Amplifier Units Connectors (Order Separately) Note: Stickers for Connectors are included as accessories. Item Shape Cable length No. of conductors Model Master connector EX-CN11 2 m Slave connector 1 EX-CN12 Precautions for ordering the connector type Amplifier Units Applicable Connector (order separately) Refer to the following tables when placing an order. Basical- Type NPN PNP + Master connector Slave connector ly, Amplifier Units and connectors are sold separately. Standard 6 8 EX-CN11 ( wires) EX-CN12 (1 wire) Please place an order after referring to the combination giv- Sensor I/O Connectors (Order separately) Size Cable type Shape Cable length Model M8 Standard cable Note: Refer to page NB-6 for details. Straight L-shaped Accessories (Order Separately) Mounting Brackets When Using 5 Amplifier Units Shape Applicable type Model Quantity # #F E9-L1 G# 1 #V E9-L18 Amplifier Units (5 Units) + 1 Master Connector + Slave Connectors 2 m XSF-M21-02-A 5 m XSF-M21-05-A conductors 2 m XSF-M22-02-A 5 m XSF-M22-05-A End Plate Shape Model Quantity PFP-M 1 A-
Rating/performance Amplifier Units NPN output Model PNP Item output Light source (wave length) Power supply voltage Type Standard models High-speed detection models Pre-wired * If 8 or more Units are installed side-by-side, the response time will be 50 s max. Mark-detecting models Water-resistant models Connector type Water-resistant models (M8 Standard models Connector) 11 11F G11 11V 6 1V 1 1F G1 1V 8 V Red LED (680 nm) Current consumption 5 ma max. Control output Response time Sensitivity adjustment Protective circuits Timer function Ambient illuminance Green LED (520 nm) 12 to 2 VDC ±10%, ripple (p-p): 10% max. 5 ma max. (at power supply voltage 2 VDC) 5 ma max. Red LED (680 nm) Load current 50 ma (residual voltage 1 V max. each) Open collector output type (depends on the NPN/PNP output format) Light-/Dark- switch selectable or reset: 200 s max. * Operating: 20 s max. Reset: 0 s max. 8-turn endless adjuster (with indicator) Reverse polarity protection, output short-circuit protection, mutual interference prevention (optically synchronized) Reverse polarity protection, output short-circuit protection -delay timer: 0 ms (fixed) Incandescent lamp: 10,000 lux max. Sunlight: 20,000 lux max. 200 s max. for operation and reset respectively (See note.) Reverse polarity protection, output short-circuit protection, mutual interference prevention (optically synchronized) Operating: Groups of 1 to Amplifiers: -25 to +55 C, Groups of to 11 Amplifiers: -25 to +50 C, Groups of 12 to Ambient temperature Amplifiers: -25 to +5 C Storage: -0 to +70 C (with no icing and condensation) Ambient humidity Operating/Storage: 5% to 85% RH (with no condensation) Insulation resistance 20 M min. at 500 VDC Dielectric strength Vibration resistance Shock resistance Protective structure 1,000 VAC at 50/60 Hz for 1 minute 10 to 55 Hz with a 1.5 mm double amplitude for 2 hrs each in X, Y and Z directions Destruction: 500 m/s 2 for times each in X, Y, and Z directions IEC 60529 IP50 (with Protective Cover attached) IEC 60529 IP66 (with Protective Cover attached) IEC 60529 IP50 (with Protective Cover attached) 500 VAC at 50/60 Hz for 1 minute IEC 60529 IP66 (with Protective Cover attached) Connection method Pre-wired models (standard length: 2 m) Connector type M8 connector Weight (Packed state) Approx. 100 g Approx. 110 g Approx. 55 g 65 g Material Accessories Case Cover PBT (polybutylene terephthalate) Polycarbonate Instruction manual Polyethersulfone (PES) Polycarbonate Polyethersulfone (PES) A- Advanced Photoelectric Sensors
Amplifier Unit Connectors Item Model EX-CN11 EX-CN12 Rated current Rated voltage Contact resistance No. of insertions Material Contacts Housing Weight (Packed state) 2.5 A 50 V 20 m max. (20 mvdc max., 100 ma max.) [By connection with amplifier unit and connection with adjacent connector (except conductor resistance of cable)] 50 times (By connection with amplifier unit and connection with adjacent connector) PBT (polybutylene terephthalate) Phosphor bronze/gold-plated nickel Approx. 55 g Approx. 25 g Characteristic data (typical) Number of Turns of Sensitivity Adjuster vs. Sensing Distance E2-T11L E2-D11L Distance (m) 1.2 1.0 0.8 # (V) Distance (mm) 00 00 0.6 200 # (V) 0. 0.2 # F 100 # F 0 2 6 8 10 Number of turns 0 2 6 8 10 Number of turns Sensing Distance vs. Hysteresis E2-T11L E2-D11L Hysteresis (mm) 100 80 Hysteresis (mm) 20 15 60 0 # (V) 10 # (V) 20 5 0 100 200 00 00 500 600 700 Distance (mm) 0 50 100 150 200 Distance (mm) A-5
Output Circuit Diagram NPN output Model Operating status of output transistor Timing chart Mode selection switch Output circuit 11 6 G11 11F 11V 1V Light Dark indicator (orange) Output transistor Load (Relay) indicator (orange) Output transistor Load (Relay) Incident Interrupted T Operate Reset (Between brown and black) Incident Interrupted T Operate Reset (Between brown and black) L (LIGHT ) D (DARK ) indicator (orange) Main circuit 2 1 Brown 1 Black Control output Blue Load M8 Connector Pin Arrangement Note: Pin 2 is open. 12 to 2 VDC PNP output Model Operating status of output transistor Timing chart Mode selection switch Output circuit 1 8 G1 1F 1V V Light Dark indicator (orange) Output transistor Load (Relay) indicator (orange) Output transistor Load (Relay) Incident Interrupted T Operate Reset (Between brown and black) Incident Interrupted T Operate Reset (Between brown and black) L (LIGHT ) D (DARK ) indicator (orange) Main circuit 2 1 Brown 1 Black Control output Blue Load M8 Connector Pin Arrangement Note: Pin 2 is open. 12 to 2 VDC Connectors (Sensor I/O connectors) 2 1 Termination No. 1 2 XSF-M21-02-A XSF-M21-05-A XSF-M22-02-A XSF-M22-05-A Color of cable conductors Brown White Blue Black Class For DC Wire, outer jacket color Connector pin No. Application Brown A Power supply (+V) White B - Blue C Power supply (0 V) Black D Output Note: Pin 2 is not used. A-6 Advanced Photoelectric Sensors
Nomenclature: Amplifier Units Sensitivity Indicator 8-turn sensitivity adjuster Lock Button Incident level indicators indicator Mode Selector Use to switch between Light and Dark modes. Timer switch : Timer function is. : Timer function is. Indicator status In addition to the operation indicator (orange), has indicators that denotes the incident level ( green and 1 red indicators). Use them for optical axis adjustment and maintenance. Precautions Correct Use Amplifier Units Design Communications Hole The window provided in the side face of the unit is a communication window for prevention of mutual interference when it is connected with the other unit. Note that the optional Mobile Console EX-MC11 cannot be used. When the incident level of the sensor is excessive, mutual interference prevention may not be activated. At that time, make adjustment with the sensitivity adjuster. When the unit is used with the EX-DA-N series, mutual interference prevention is not activated. Mounting Connection/removing of amplifier units (Connection) 1. Install the Amplifier Units one at a time onto the DIN track. Indicator status (L/) indicator (L/) Incident level indicator Incident level indicators Not lit Lit (See note) Not lit Approx. 80% to 90% of operating level 2. Slide the Amplifier Units together, line up the clips, and press the Amplifier Units together until they click into place. Not lit Approx. 80% to 90% of operating level Not lit or lit Lit Approx. 90% to 110% of operating level Approx. 110% to 120% of operating level Clip Clip into place (Removing) Slide one unit away from the other and remove them one by one. (Do not remove the connected units together from the DIN rail.) Note: 1.When the amplifier units are interconnected, the operating ambient temperature changes depending on the number of connected amplifier units. Check "Ratings/Performance". 2.Before connecting or removing the units, always switch power off. Note: The rightmost indicator is turned at the "0 incident level". Lit Approx. 120% min. of operating level Operating Environment Ambient Conditions Always remove dust, dirt, etc. from the optical communication window, which may disable communication. Miscellaneous Protective Cover Be sure to set the Protective Cover before use. A-7
Amplifier Unit Connectors Installation Installation Connectors 1. Insert the Master or Slave Connector into the Amplifier Unit until it clicks into place. Mounting End Plate (PFP-M) Depending on the installation type, an Amplifier Unit may move during operation. In this case, use an End Plate. Before installing an End Plate, remove the clip from the master Amplifier Unit using a nipper or similar tool. Insert 2. Join Amplifier Units together as required after all the Master and Slave Connectors have been inserted.. Apply the supplied seal to the non-connection surface of the master/slave connector. The sensor bottom is also equipped with the clip removing mechanism. 1. Insert the clip to be removed into the slit underneath the clip on another Amplifier Unit. Sticker Note: Apply the seal to the grooved side. Sticker Removing Connectors 1. Slide the slave Amplifier Unit for which the Connector is to be removed away from the rest of the group. 2. After the Amplifier Unit has been separated, press down on the lever on the Connector and remove it. (Do not attempt to remove Connectors without separating them from other Amplifier Units first.) 2. Remove the clip by rotating the Amplifier Unit. Rotate Press down Lever Remove Pull Strengths for Connectors (Including Cables) EX-CN11: 0 N max. EX-CN12: 12 N max. A-8 Advanced Photoelectric Sensors
Dimensions (Unit: mm) Amplifier Units Pre-wired 11 11F 1 1F G11 G1 With Mounting Blanket Attached Incident level indicators indicator (A)*1 -dia., -conductor, vinyl-insulated round cable (conductor cross-sectional area: 0.5 m u; insulation diameter: 1.1 mm) Two, 2. dia. 10 1.05 15.75 9.2 8.6 6. 5. 8 1.5 Mounting Holes 2-M 10.7 9.9 10.75.1 22. 1.8 Two,.2 dia. holes.. Holes for optical communications * 2 2. Mounting bracket (E9-L1); Sold separately Stainless steel (SUS0) 22. Note: * 1. The mounting bracket can also be used on side A. * 2. The hole for optical communications is for preventing mutual interference. There is no hole for #F models. Amplifier Units with cables, Water-resistant Models 11V 1V With Mounting Blanket Attached 28.65 9.2 25.95 * 2 Two, 2. dia. 12 indicator Incident level indicators 81.5 6.9 0 (A)*1 8 2.8 10.7 9.9 11.2 Mounting Holes 2-M.9.. 2.9 1. 7 11.5 67.2 2.9. 5. Holes for optical communications 6.6 Mounting bracket (E9-L18); Sold separately Stainless steel (SUS0) 5.. Note:*1.The mounting bracket can also be used on side A. *2. -dia., -conductor, vinyl-insulated round cable (conductor cross-sectional area: 0.5 mm²; insulation diameter: 1.1 mm) A-9
Connector type 6 8 indicator Incident level indicators 1.05 15.75 9.2 10 6. Two, 2. dia. 8 10.7 9.9. 1 5.5 1.5 1.8 1.7 1 5.1.9 1.8 8.6 6.7 Holes for optical communications (for preventing mutual interference).2 Dimensions with Master Connector Connected 71 67.5 6. 6.2 1.7 Dimensions with Slave Connector Connected 71 67.5 6. EX-CN11:.0 dia. EX-CN12: 2.6 dia. 1.5 1.5 1.5 12.95 1.5 17.5 12.95 11.55 1.8 5.1.9 10 1.8 5.1.9.8 10 Amplifier Units M8 Connectors, Water-resistant Models 1V V Note:*1.The mounting bracket can also be used on side A. With Mounting Blanket Attached 28.65 9.2 25.95 Two, 2. dia. 12 indicator Incident level indicators 81.5 6.9 0 (A)*1 8 2.8 M8 10.7 9.9 11.2 Mounting Holes 2-M.9.. 2.9 1. 7 11.5 67.2 2.9. 5. Holes for optical communications 11 Mounting bracket (E9-L18); Sold separately Stainless steel (SUS0) 5.. A-50 Advanced Photoelectric Sensors
Amplifier Unit Connectors Master connector EX-CN11 2.9 10 6 2.6 6.8 10.7 2,000 +50 0 -dia., -conductor, vinyl-insulated round cable (conductor cross-sectional area: 0.5 mm²; insulation diameter: 1.1 mm) dia. 1. 6 0.8 8. 15.1 0± 2 50 +5 0 10± 2 Slave connector EX-CN12 2.9 10 6 2.6 2,000 +50 0 6.8 10.7 -dia., -conductor,vinyl-insulated round cable (conductor cross-sectional area: 0.5 mm²; insulation diameter: 1.1 mm) 2.6 dia. 1. 6 0.8 8. 15.1 0± 2 10± 2 50 +5 0 Accessories (Order Separately) Mounting Brackets H-5 A-51
ALL DIMENSIS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.097. To convert grams into ounces, multiply by 0.0527. Cat. No. E2E-EN-01 In the interest of product improvement, specifications are subject to change without notice. A-52 Advanced Photoelectric Sensors