Wing Watch Lite. Battery Monitoring System. User Manual

Similar documents
H3G-380 Production Description

H3G-48B Production Description

W Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2

RangerBOSS Network Ready Constant Monitor Model CM2800

I. PANEL DESCRIPTION... 1

NO: PH-185 PRODUCT: E3JK Photoelectric Sensors DATE: May 2014 TYPE: Discontinuation Notice

the Interactive Catalog

Data logger systems from ROTRONIC

Digital Keypad Introduction

M15S OPERATION MANUAL

UC-2000 Installation Manual Unicorn Computers Technology Limited

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

716 Converter. Programmable Data Converter

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

INSTALLATION GUIDE FOR IRRIGATION

AirTest Model CN9000 Series Sensor Controller

INDEX. Analog Board Boot and Voltage Test 2 Testing Input Channels 3 Testing Output Channels 4

MCX08M2 Programmable controller

SeaViewer Cameras, Inc. DVR-SD. SD Digital Video Recorder. User s Manual

H3G-TA ENGINEERING MANUAL

Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours!

Multi-IQ. Firmware: RS232-Data Manager for UPS 4 x RS232 / 1 x LAN-Contacts flash upgradeable. User manual. (Serial Number / Seriennummer)

Model Instruction Manual. Heat Stress Meter. reedinstruments. www. com

Product discontinuation. Notices

Connecting a Cisco Reader Module

WIRING DIAGRAMS NVIROMON NDCNTRLRS485. Remote Environmental Monitoring and Control for IT equipment. NVIROMON

JANUARY 2000 TS800A TS801. MicroScanner

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

PowerShield 8. Installation Manual

TA715/777 Installation and Operation Guide

DS Type: MAXIM III Controller

H3G-TV ENGINEERING MANUAL

Wireless Data Logger System

LE ELECTRONICS Pvt. Ltd.

_ Access control SISTEMAS DE SEGURIDAD

USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output

IPDU-A Series User Manual. IPDU-A Series User Manual

NSGV Series "90DM3" Carbon Dioxide Detector

IPassan Installation guide

The 3-phase, 5-wire model name is PF LNM. The 3-phase, 4-wire model name is PF LNN.

LANCNC FTP Data Server for CNC Controls Machine Mount instructions

HUAWEI FT2260 Home Phone Connect Quick Start

TS InteliSwitch Digital Time Switch 24VDC/VAC

Hardware User s Manual. Digital Video Motion Detector DVMD1-X

Note: the wiring of the dead-man buttons has been changed since October 2001.

24/48V Battery Bank Ah High Cycling Long Life

MAGUIRE G2-ES Configuration Instructions for Ethernet to Serial Converter Model: Moxa NPort 5110 Serial Device Server

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out

VIDI System Controller

TIME DELAY RELAYS Product Summary

AC5102. Features. Advanced Central Controller

AC Power Probe, ACL1 (#30015)

Innovative Electronics for a Changing World INDEX

Ethernet / RS485 Gateway

2400 Series. Installation & Operations Manual. 42 Central Drive Farmingdale, NY

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

WTX110. Legal-for-trade industrial weighing terminal. Special features. Data sheet

VersaMax Micro and Nano Technical Product Presentation

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

User Manual. Solar Inverter for Water Pump

GV-EL124S Electric Strike

ACTpro Single Door IP Controller. Operating & Installation Instructions

Crestron SmarTouch STS

CV-945 Stand-Alone Biometric Reader. Installation Instructions

DMT345 and DMT346 Dewpoint Transmitters

Short guide. Trackunit 401 SmartID. Version 1.4, June 2014

MEASURING AND TESTING INSTRUMENTS

Pow-R-Command 1000 universal I/O module

SMART SHOT CONTROLLER FLUID USERS GUIDE

DS October MAXIM 1010 Controller

Electronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features

SNAP-IT-PM Installation Guide

Installing Sentor. Hardware Installation

Flamma BIOMASS COMBUSTION SYSTEM CONTROLLER. Preliminary Description V.1 Santi Moroño / Jose Caldelas / Juan R. Regueiro / 26/02/ :34

PurClean/PurWater (RO/Reclaim) Water Analytics

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc.

For more details and updates go to our website, boatcommand.com.

Installation of the PCMeasure Movement Sensor (30114)

2 in 1 LAN Tester and Multimeter Model:

H3G-TV Introduction. Huasu Technology

BEP 600-ACSM AC SYSTEMS MONITOR. Installation and Operating Instructions. Page 1

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

LCD240-xHxx. INSTALLATION MANUAL LCD240 Horizontal Graphic LCD Display Device for Lifts. Part No.

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Andover ContinuumTM Infinet II

Multifunction Calibrator

SBS-S SERIES DC LOAD BANK USER MANUAL

Restock fee of 10% applies

Net Prowler TM Identify, Monitor & Test LAN Issues

02/11/2015

Engineering Note: EN0047 Commissioning a Hydro-Probe with a Command Alkon EZCal Station

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

DC POWER SUPPLIES DNX 110/220 V

MIRRIN. Multi-Channel Load Logger MODEL: LL400 User Manual 1 GETTING STARTED INTRODUCTION CONNECTIONS

WTX120. Legal-for-trade industrial weighing terminal. Special features. Data sheet

AC-DC Converter REC K10

4-20 ma Output Board Dual Channel

ACCESS CONTROL SYSTEM

Transcription:

Wing Watch Lite Battery Monitoring System User Manual February 2009

Check the contents: The Wing Watch-Lite is packed in soft, protective material inside a carton box. There are 5 sets in each packaging. Every package should contain the following items: 1. one piece of Wing Watch-Lite Battery Monitoring System Controller 2. one pair of 19 rack mount brackets for the system controller 3. one piece of communication cable (RJ-11 plug on each end) 4. one BMM-12* battery probe 5. user manual (one manual per box) Please refer to the follow diagram to check the box contents. *BMM:Battery Management Module

1 5 2 3 4

1. Introduction Wing Watch-Lite is designed for telecom power battery backup systems, which typically involve 48VDC battery strings. Because of the high power and energy storage requirements, these systems use large numbers of battery blocks from 32 up to 192 blocks and these systems require very detailed recording and even more comprehensive alarm functions. Wing Watch-Lite is designed mainly for small system backup batteries monitoring purpose. In general, systems installed inside street cabinet or BTS (mobile base stations) are the expected applications. These usually use one or two strings of 4x12 volt battery blocks. The basic need is to be able to generate alarms when one of the following situations occurs: -under or over voltage condition -battery temperature out of tolerance -unbalanced battery block voltage

2. Technical Features Wing Watch controller Monitoring Input: 1 or 2 pieces of BMM-12 (each BMM has 4 cell voltage monitoring channels with RJ-11 jack (same port in parallel) Alarm output : 3 dry contacts Relay 1 - block voltages unbalanced (Deviated more than preset percentage from average block voltage) Relay 2 Block and/or string voltage over- or under an absolute preset voltage Relay 3 the temperature detected by the on-board sensor inside the BMM battery probe is over the preset temperature threshold Power input: 220VAC -DC12V AC/DC power supply or DC36-70V, 25mA for 1 BMM-12 probe and 32mA for 2 BMM-12 probes Communications options: LAN or RS-232/RS485 for connecting to remote computer Display: 2 x 20-character LCD display white back light with screen saver

LED indicators: DC in Run Alarm Key Pressed BMM Com BMM Com failed (DC present) (CPU running) (system has alarm(s)) (blink on pressing) (BMM data in/out) (lights up if controller cannot communicate to BMM) Keypad: 6 keys for menu control Software options: RS-232/485 or LAN option available for the Wing Watch-Lite Controller Wing Watch remote monitoring software available for monitoring via LAN/intranet to 3000 sites or more.

3. System Connection 3 Alarm dry contact outputs + Voltage Unbalance 12VDC TCP/IP LAN 48VDC - Over or Under (Not used Option Voltage unless Not used unless specified) ordered Over Temperature BMM-12 Battery probes Red Brown Blue Grey Black

Install the pair of 19 rack mount brackets: Unscrew six screws on both sides of the Wing Watch-Lite controller : Then install the mounting brackets onto both sides of the controller. Please refer to the diagrams above. After that the controller can be mounted in a 19 rack as below:

Connect the system as shown in the beginning of section 3. Connect the probes, one BMM-12 probe for each four blocks of 12V battery. The color of the wire is marked on the BMM-12 probe. Use strong and heat resistant double-sided tape to fix the probe on one of the battery (recommended for measuring the surface temperature of at least one battery. You can connect one additional probe by an interconnecting RJ- 11 cable. The current version supports only 2 probes. This cable is the same as the long one between the controller and the first BMM- 12 (address 1). After that the system can be powered up. Section 5 describes the keypad operations for the entire menu on the LCD display.

4. Wing Watch-Lite controller LCD panel operations The following shows the six keys on the LCD panel: After power up, a system status display screen appears and waits for further command. If the screen appears blank, press key. The system status display shows data of the first BMM- 12 probe which consists of the average block voltage (average of 4x12V block), the string voltage (total of 4x12V blocks) and the on-board temperature sensor value. Use the key to go to: view data of the second probe (if installed). The user can go through the different commands by pressing the key. Use the key to move to the desired field. Use the key to modify the value. It is also used to mute the audible alarm. Press until cursor does not blink anymore. Changes will be saved/exit. Press any menu. Similar: press key to see the battery data from to see active alarm records from any menu. A description of the different operations on the LCD display is given from the next page.

Power up screen system status display BMM-12 battery probe voltages Set maximum number of probes and the percentages of voltage deviation which is allowed between the blocks

(Repeat this key to position cursor) (Repeat this key to position whitout a blinking cursor before going towards the next menu)

Repeat menu for: Set block/cells Over-voltage (OV) per string and per block Low voltage (LV) alarm threshold per sting and per block Set block and string low voltage alarm threshold Temperature Number of BMM s Deviation percentages Power on/off battery probes & set the number of blocks to be monitored by the BMM-12 power on/off the BMM-12 View alarm history use Modify key to scroll through the alarms (see below View Firmware version ALARM

View alarm history. Use Select key to scroll to the list. Press Modify key to show the list. Use Modify key to enter the next record. Press Select for previous record. End of Manual