in ICT Prof. Dr.-Ing. Wolfgang Nebel OFFIS Institute for Information Technology

Similar documents
BENEFITS OF ASETEK LIQUID COOLING FOR DATA CENTERS

Application of Green Technology For Data Centre

The End of Redundancy. Alan Wood Sun Microsystems May 8, 2009

Server room guide helps energy managers reduce server consumption

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Power & Cooling Considerations for Virtualized Environments

Green IT. Finding Practical Efficiencies. Infrastructure Planning and Facilities. Green IT: Finding Practical Efficiencies

Green IT and Green DC

IT Level Power Provisioning Business Continuity and Efficiency at NTT

Systems and Technology Group. IBM Technology and Solutions Jan Janick IBM Vice President Modular Systems and Storage Development

Overcoming the Challenges of Server Virtualisation

Make the most of your Energy from Power Plant to Plug. Chris Simard, Regional Director Field Sales Group

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

Case study on Green Data Center. Reliance Jio Infocomm Limited

Energy Usage in Cloud Part2. Salih Safa BACANLI

COMPANY PROFILE. shindetek. supporting technologies

Energy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director

E f f i c i e n c y b e y o n d t h e A C b a s e d d a t a c e n t e r d e s i g n s ; V D C p o w e r f e e d s o l u t i o n

Green Data Centers A Guideline

A Computer Scientist Looks at the Energy Problem

Addressing Data Center Efficiency Lessons Learned From Process Evaluations of Utility Energy Efficiency Programs

Microsoft s Cloud. Delivering operational excellence in the cloud Infrastructure. Erik Jan van Vuuren Azure Lead Microsoft Netherlands

IBM eserver Total Storage, On Demand

The ETNO CORE Energy Task Force

Energy Efficiency : Green Telecom

MSYS 4480 AC Systems Winter 2015

The Greening of Services

How much power?! Data Centre Efficiency. How much Money?! Carbon Reduction Commitment (CRC)

Next Generation Cooling

Data centers control: challenges and opportunities

Technology Changes in Data Centers

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

BX900 The right server for virtualization applications

Workshop on the IPv6 development in Saudi Arabia 8 February 2009; Riyadh - KSA

Navigating the Pros and Cons of Structured Cabling vs. Top of Rack in the Data Center

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

Data Center Trends and Challenges

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

Exploiting Temporal Diversity of Water Efficiency to Make Data Center Less "Thirsty"

Data Centers. The Environment. December The State of Global Environmental Sustainability in Data Center Design

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

Newave s approach for protecting mission critical application

Tel: AC Power for Business-Critical Continuity TM

White Paper - Infrastructure in an energy-efficient data centre

UPS PRO MODERNÍ DATOVÁ CENTRA. Rastislav Smatana AC Power Sales Manager CZ&SK

Green Computing and Sustainability

E e n rgy g y St S ud u y y Pr P og o r g ams December 2011

LCP Hybrid Efficient performance with heat pipe technology

Improving the climate for data centers

DATA CENTER LIQUID COOLING

Green Computing: Datacentres

DC Energy, Efficiency Challenges

Data Center Energy and Cost Saving Evaluation

Cloud environment. dr inż. Piotr Boryło , Kraków

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

SDN-Based Open Networking Building Momentum Among IT Decision Makers

STULZ Micro DC. with Chip-to-Atmosphere TM Liquid to Chip Cooling

ECOBAY: Closed loop water cooled server cabinet for data centers

The Environmental Footprint of Data Centers: The Influence of Server Renewal Rates on the Overall Footprint.

Planning a Green Datacenter

Sustainability Session. #4: Green IT

HP environmental messaging

Dave Donatelli Executive Vice President & General Manager HP Enterprise Servers, Storage & Networking

EP s approach to Power & Energy efficiency in DCs & paradigms

High Density Cooling Solutions that work from Knurr Kris Holla

SOLAR ENERGY DEVELOPMENT IN MOROCCO

THE CURRENT STATE OF DATA CENTER ENERGY EFFICIENCY IN EUROPE. White Paper

A TAXONOMY AND SURVEY OF ENERGY-EFFICIENT DATA CENTERS AND CLOUD COMPUTING SYSTEMS

Data Centre Energy Efficiency Product Profile

Next Generation Data Center Facilities Design. Presenter: Ping Lin

TWO FINANCIAL IMPACT STUDIES. Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months

Ecolibrium. Cloud control. Keeping data centres cool. OCTOBER 2018 VOLUME 17.9 RRP $14.95 PRINT POST APPROVAL NUMBER PP352532/00001

Energy Management of the Refrigeration Systems at Zurich Airport. Burkhard Bein. Schaffhausen,

Reducing Emissions Re-enables Growth; Electronics Provides the Key. Presented by : Robert Barnes Date : 2 nd December2010

Topics. CIT 470: Advanced Network and System Administration. Google DC in The Dalles. Google DC in The Dalles. Data Centers

Hot vs Cold Energy Efficient Data Centers. - SVLG Data Center Center Efficiency Summit

White paper adaptive IT infrastructures

Gartner and Green. Michael Tapuni

Using CST Microwave Studio Distributed Computing in a Workgroup Environment

Virtualization and consolidation

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

Data Center Carbon Emission Effectiveness

Your data center s hidden source of revenue

Rack cooling solutions for high density racks management, from 10 to 75 kw

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Shared Infrastructure: Scale-Out Advantages and Effects on TCO

Rockwell Automation ODVA Annual Meeting

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Energy Efficient Data Centers

The Power Wall. Why Aren t Modern CPUs Faster? What Happened in the Late 1990 s?

White Paper Energy Consumption ESPRIMO E Watt

The Efficient Enterprise. All content in this presentation is protected 2008 American Power Conversion Corporation

Optimization in Data Centres. Jayantha Siriwardana and Saman K. Halgamuge Department of Mechanical Engineering Melbourne School of Engineering

April Power Systems Roadshow

Eaton Open Data Centre Solutions. Kari Koli

Recapture Capacity for Existing. and Airflow Optimization

Procurement on modernisation of the server platform of the municipality

Rack & Enclosure Systems

Imagine a place where the energy is green and excess data center heat isn t wasted. Imagine Stockholm.

IBM Symposium Data Center Cooling. EC Systems for HVAC architecture and Direct air Cabinet Cooling

Transcription:

Energy Efficiency i in ICT Page 1

Energy Consumption, Climate Protection, Costs Power Consumption of ICT (End Devices and Infrastructure) in Germany (Source: Cremer et al. 2003) 2001: 38 TWh (8% of power consumption) Compared to 10.7 TWh generated from wind energy (Source: Bundesverband Windenergie) 2010: 55 TWh (11% of power consumption) CO 2 -Emissions 2004 in Germany ICT: 28 Mio. t CO 2 (due to power consumption) Compared to complete aircraft traffic of 22 Mio. t CO 2 Increase especially in ICT-Infrastructure (UMTS-Network, Servers, Routers etc.) The highest electricity consumers are data centers Servers: 180 TWh in 2005 relate to 18 nuclear power plants worldwide 80% of all servers are located in data centers Increase of Operating Expenses due to Energy Costs Energy costs worldwide for servers in 2008: approx. 40 billion US$ Soon 50% of operating expenses will be caused by power supply and cooling Page 2

Energy Consumption of ICT in Germany ICT-infrastructure in private homes Infrastructure mobile communication Audio stationary Server, office TV Source: Borderstep 2007/Cremer et. al. 2003 Page 3

Worldwide Energy Consumption of Servers 2005 vs. 2000 3 2,5 2 1,5 Reference 2000: 1 0,5 0 Volume Mid-R Range High-End Total Anzahl Number Energie/Server Energy/Server Gesamtenergie Total Energy Source: Koomey, 2007 Page 4

The Economic Consequences Source: IDC 2006 Page 5

Problem Awareness of Data Center Operators Power supply and cooling together: 74% Page 6

Energy Consumption in Enterprises (2,500 PCs) kwh 1000000 800000 600000 400000 200000 0 uncon ntrolled centraliz lized PM switched off Closing time Working hours Source: Gartner 2007 Page 7

Core of the Problem: The Required Computing Performance Source: tom s hardware guide Page 8

Cause: The Performance Barrier Source: tom s hardware guide Page 9

Technical and Economic Challenges Limited Run-Time Energy demand raises faster than battery capacity Problematic for mobile devices: notebooks, mobile phones, PDAs, Added Costs Typically relevant for devices for private use: desktop PCs, TVs, DVD players, Of increasing importance in the commercial domain: e.g. work station PCs Energy Required by Mobile Devices Battery Capacity Generation Energy Supply and Disposal Problem Increasingly problematic in data centers Complex air conditioning for 1:1 energy disposal required Sometimes, even the supply of energy is a problem Supply (electrical) Disposal (thermal) Page 10

Abstract Examination Energy Efficiency What is Energy Efficiency? ss not efficient efficient optimize ffectivene e Conclusion: Energy efficiency i can be achieved by: Light Bulb Energy Saving Bulb LED Illuminant umption to usage ergy consu portional t ene pro 1 always on Energy Energy Efficiency Optimized effectiveness Energy consumption proportional to usage High utilization 1 Energy light dimmed, if room not used Energy Efficiency 1 light off, if room not used Energy Efficiency Energy Utilization of the Room 1 Utilization of the Room 1 Utilization of the Room 1 efficient only at high utilization always efficient Page 11

Practical Implementation Energy Efficiency in Mobile Phones Optimize Effectiveness Adoption of low-power technologies and design solutions in chip development Objective: minimizing steady-state power dissipation Raising Utilization By means of load alignment low V T high V T Dual VT Sleep States standby Energy Consumption Proportional to Usage Sophisticated power management Disabling unused circuits Reducing gperformance during gphases of lower utilization Objective: Customizing the energy consumption according to the respective usage scenario controlled by utilization DVFS Conclusion: Due to technical problems, vigorous usage of techniques to raise energy efficiency DISPLAY Clk Circuit V DD Page 12

Practical Implementation Energy Efficiency in PCs 1/3 Optimize Effectiveness Technically feasible: low power CPU, low power graphics card, 80% mains supply, thus no need for a fan Today, instead of energy consumption rather performance and pricing are important purchase criteria Only secondary effects (fan noise, high temperatures and short battery life time in notebooks) are reasons to purchase energy efficient systems Raising Utilization Matching of the resources sending emails and surfing needs no high-end PC Matching of the load temporally - spatially Energy Consumption Proportional to Usage Technically feasible: Shut down of individual components (hard disc, display, ) possible Low power consumption during standby state Controlled by software with a timeout-based power management Page 13

Practical Implementation Energy Efficiency in PCs 2/3 Problems of the Present Timeout Based Power Managements Idea: After some idle-time, the user is considered to be absent -> turn off device (e.g. display) Error-prone (e.g. while user reads) The chosen balance between saving energy and annoyance often is to the disadvantage of energy saving Solution: Intelligent Power Management Idea: Adapt the power management to the pattern of use For the first time, basic research was included in a product Intel06 Page 14

Practical Implementation Energy Efficiency in PCs 3/3 Comparing Results of Adaptive vs. Timeout Based Power Management Use case: Work of a traveling salesman Runtime of the notebook without PM: 5h Due to breaks (phone call, reading of papers, ) max. extra time: 83min adaptive more energy efficient, with less false shut downs lon nger run ntime annoyance 83min timeout based 0min nstop on Maximum at optimal power management 21min aptop 54min minim mum battery usage 62min Conclusion: Energy efficiency is often a question of financial sweeteners No L scalable Technical possibilities are available; but until now not sufficiently used adaptive Page 15

Practical Implementation Energy Efficiency in Data Centers 1/3 Effectiveness Energy efficiency only if neutral to performance Mains supply with high effectiveness (e.g. in Blade servers) Smaller improvements are possible, but one cannot expect major advancements in the near future Optimize Utilization Average utilization of today s servers (measured approx. 5,000 servers over a 6 month period) Source: Google 2007 Page 16

Practical Implementation Energy Efficiency in Data Centers 2/3 Optimize Utilization Additional strong dependency on time and type of server Optimization by consolidation Implementation of several servers on one hardware resource Realization by virtualization several virtual operating systems are independently executed on one single host system Source: Vossel Solutions Page 17

Practical Implementation Energy Efficiency in Data Centers 3/3 Energy Consumption Proportional to Usage typical load Früher Past State-of-the-art Vision 1 Energy 1 Energy 1 Energy Efficiency Energy Efficiency Energy Efficiency Energy 1 1 1 Server without power management Power management in modern CPUs result in Complete usage dependant energy consumption Constant consumption Energy efficiency only depending on a minor utilization dependant consumption in Blade servers load Realizable by global power management in the entire data center utilization dependant control of mains supply Conclusion Research Project at OFFIS Raising the load by consolidation Nearly complete usage-proportional p energy consumption is reachable with system wide power management Without penalty on performance With higher availability Page 18

Practical Implementation Possibilities by System Management Virtualized Data Center Regarding their behavior, known and unknown virtualized servers System Management monitors virtualized servers monitors and controls the hardware resources plans binding monito ors/ contr ols Hardware Resources R n R 3 R 2 plans System Management R 1 binding monitors optimization criteria virtualized servers G 1 G 5 G 2 G 3 G 4 G 6 known unknown Optimization Criteria ia Energy/Performance thermal behavior homogeneous aging 1 energy efficiency energy 1 performance/ energy optimization prevention of thermal hot-spots reduction of inhomogeneous aging g Page 19

Power Consumption of German Data Centers Scenario state-of-the art Scenario present efficiency trends Scenario best-practice present development Source: Borderstep 2007 Page 20

CO 2 Emissions of German Data Centers Scenario present efficiency trends Scenario state-of-the-art Scenario best-practice present development Source: Borderstep 2007 Page 21

Energy Costs of German Data Centers Scenario present efficiency trends Scenario state-of-the-art Scenario best-practice present development Source: Borderstep 2007 Page 22

Practical Implementation Example Projects Strato s CO 2 -free Data Center Increased energy efficiency Low power CPUs, optimized software (Sun Solaris 10) optimized building services and air conditioning Energy supply by water power The green Data Center of Host Europe Highly available and energy efficient, Raised effectiveness of the supply components, cooling with outside air,, 30% lesser energy consumption Bio-Gas Fuel Cell in T-Systems RZ-Munich Our servers devour green stuff 250 kw of altogether 10 MW Page 23

Finally Google 2005 1 cluster = 31,654 servers served 40 Mio. requests/day costs about 300 MWh/day one request costs about 8 Wh Second Life 2007 approx. 2000 servers 36,000 players simultaneously one avatar costs about 195 kwh/year or 129 kg CO 2 Compare: a human exhales about 250 400 kg CO 2 Thanks to Rolf Kersten: http://blogs.sun.com/rolfk/ Page 24

Conclusion Technical problems already force manufacturers of mobile devices to implement radical new concepts. Increasing technical, economic and environmental interest in energy efficiency in data centers and ICT-infrastructures: Potential and first technical alternatives are already available. Further innovative ideas have to be developed and evaluated. Holistic concepts have to be developed. Savings potential in 2010 more than 8 TWh / 5,4 Mio t CO 2 / 1,1 Mrd. Very ygood prerequisites for applying ppy new technologies, since environmentally and economically reasonable, technically required and feasible. Actions Raise cost awareness in decision makers Best practice information Roadmap to coordinate suppliers towards market launch Flagship initiatives (improving the state-of-the-art) Energy-labels for the consumers market Page 25