Tstat8. Bacnet Thermostat

Similar documents
T3 Series Bacnet Programmable Controller

CONTROLS.COM. Bacnet and Modbus Modules. T3-22i. T3000 Building Automation System Overview. T3-8o. Ethernet MAIN NET1 RS485 SUBNET2 RS485.

T3 Series Bacnet Programmable Controller

USER S MANUAL. DAS-G01 The Power of Tomorrow

Andover ContinuumTM. b3850 Series Terminal Controllers

ExactLogic BACnet Communicating Pressure Dependent VAV Damper Control with Heat EXL01820 Sequence Datasheet

Richmond Heights. Smart Wi-Fi Capacitive Touch With Dual Protocols Universal Controller. Go Green

BACnet Product Overview

DataNab it8: Intelligent Communicating Thermostat

ExactLogic BACnet Communicating Thermostat EXL01716 Sequence Datasheet Duel Deck VAV

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

Field selectable application type and room module series, via dip-switches on controller

System Controls Suggested Specification

Specification Sheet For electronically commutated motors

PM2.5 Particle Counter

75F Smart VAV with Reheat

HLS34 Modbus FCU/VAV Controllers installation instructions

ExactLogic BACnet Communicating Zone Damper EXL01710 Sequence Datasheet

Suitable for a wide range of installations with wall-mount, flush-mount and hand-held remote control options.

clarity 3 Programmable Controller

FCU-4 FAN COIL CONTROLLER

THERMOSTATS & CONTROLLERS

Tracer Controls. Tracer MP501 Controller BAS-PRC008-EN. January 2005

PMX 2.5/10 - Combined High Quality Indoor/Outdoor Monitor

Networkable Dual Duct VAV Controller Specification and Installation Instructions

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

Product Catalog. Tracer Controller MP501 BAS-PRC008-EN. May 2012

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller for Smoke Control

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

Siemens BACnet Programmable TEC Unit Conditioner Controller

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

BACnet. b3867 Terminal Controllers

Millennium Simplicity Elite Parameter Points and Quirks

Tracer Controls. Tracer MP.501 Controller BAS-PRC008-EN. June 2001

BACnet. b3810 Series Local Controllers

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

TF243 Series Digital Thermostat Fan Coil Unit Control

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller

ExactLogic BACnet Communicating Thermostat EXL01816 Sequence Datasheet

Economizer Control 2-1

Humidity / Temp Transmitter

Smart Equipment Controls (SEC)

CONTENTS CONTROLLERS room controllers room units control units PRODUAL 3 CATALOGUE

Andover ContinuumTM Infinet II

NT10 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

FCU-4 FAN COIL CONTROLLER

LX Series Free Programmable Controllers

FUME HOOD CONTROLLER (FHC)

Introduction. To use Carrier wireless sensors, you must have: A i-vu v6.5 or later system v6-00 or later drivers

SE7600E Series Application Guide

Andover ContinuumTM Infinet II

Siemens BACnet Programmable TEC Unit Vent Controller

BUILDING MANAGEMENT. OpenBAS-HV-NX10 SERIES CATALOG NUMBER. Description. Features

Siemens BACnet Programmable TEC Constant Volume

Underfloor Controllers

Networkable VAV Controller Specification and Installation Instructions. Controller Model EVCB14NIT4X (4 TRIACS / independent / external motor)

BACnet PTEC Controller Constant Volume - Cooling Only, Application Application Note Building Technologies

MOD-RI Room Interface Modules with Modbus

MANUAL INSTALLATION + SERVICE. Price Intelligent Controller. PIC Series. v400 Issue Date: 12/18/ Price Industries Limited. All rights reserved.

Andover ContinuumTM Infinet II

SCC Inc. TS Series. Technical Instructions. Document No. TS-2000 March 15, 2016

NT50 Series RS485 Modbus RTU Networking LCD Fan Coil Thermostat

Datasheet ECB /6. BACnet B-ASC 10-Point Programmable Controller. Overview

RCF-230CAD. Communicating room controller for fan-coil applications with two analogue V DC outputs

clarity 3 VAV Programmable Controller

Room controller STRA-17

QUICK START GUIDE M2000 SERIES rue Charles, Suite 100, Mirabel, QC, J7J 1X9

RCF-230CD. Communicating room thermostat for fan-coil applications with on/off outputs

M1000 INTELLIGENT ZONE CONTROL SYSTEM

Microprocessor Based Thermostat

Siemens BACnet Programmable TEC Unit Vent Controller for Smoke Control

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

RWD68U Universal Controller

SE7600E Series Application Guide

INSTALLATION INSTRUCTIONS MBPEFY Series Mixing Box for Mitsubishi PEFY Series Units. Before Starting Installation Warning. Installation Instructions

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

X47.CE Product Guide

HARDWARE GUIDE. Water Loop Controller C1000 Series. Specifications and Operational Guide

Installation and Operation. Tracer MP501 Controller CNT-SVX08B-EN

SE8300 Room Controller

Temperature controller Ducted systems

Siemens BACnet Programmable TEC VAV with Series Fan and 3-Stage Electric Heat Controller

AIR HANDLING UNIT CONTROLS

Room Controllers SER8300 Line Voltage Fan Coil Controller with SC3000 Relay Pack

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

Economizer Controller Installation Guide

FXVMA Variable Air Volume (VAV) Box Controller

Datasheet. ECB-PTU Series. 1/14. BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview

Communicative controller for VAV systems

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

Description. descriptors, makes set-up and monitoring very user friendly.

Microprocessor based Temperature / CO2 Controller c/w 365 Day Time Switch & Modbus Communication.

BT300 HVAC Drives. Designed for HVAC. Description. Technical Specification Sheet Document No March 4, 2013

Fast Route to Reliable Energy Savings ZIP Economizer

SED2 Variable Frequency Drives

T3-6CT. Highlights: Surge-Protected Analog Inputs with 10-bit Resolution

L Connection Network Control System For Energence Rooftop Units

HT Series Wall Mount with Relay Setpoints, LCD, and Humidistat and Thermostat Control

Transcription:

Tstat8 Bacnet Thermostat This full-featured thermostat is designed for cooling and heating systems in residential and commercial buildings. The thermostat can be configured for use with air handlers, fan coils, VAV, modulating valves and practically any HVAC application. All models support bacnet and modbus protocol which allows easy integration with the big name control systems like Niagara, Siemens, Honeywell, Johnson Controls, Delta, Reliable and Kreuter to name a few. There are five relays and two analog outputs as well as 8 universal inputs. These i/o can be configured using the free software. There are more than 300 settings with many options for each of the settings so its possible to configure these devices for most any application. Once the unit is configured, save the config file for copying to other controllers and backing up project settings. Options are available for occupancy sensor, zigbee, and humidity / enthalpy. Highlights Bacnet MSTP and Modbus RTU protocols over RS485. T3000 software Baudrates : 9600, 19.2k, 38.4k, 57.6k, 76.8k and 115.2kBaud. Well documented register list for easy integration with other systems. 8 universal inputs for external temperature sensors, contacts, etc. 5 relay outputs, each rated at 24vac, 2 amps. 2 analog outputs, 0-10V @ 100ma. Color LCD display with scroll bar. Easily configure the thermostat for practically any application. Clock with infinite life supercap battery backup. Uses 32 bit Arm CPU with 12 bit analog readings. Typical Application HEAT PUMP TEMPERATURE FILTER SWITCH FAN COIL AIR HANDLER OCCUP SENSOR FLOW SENSOR FAN STATUS WINDOW CHANGEOVER PUMP POWER METER BTU METERS MODULATING VALVES MODULATING DAMPERS 01 RS485 Ethernet Internet REMOTE USERS LOCAL USERS

Tstat8 Bacnet Thermostat Specifications Outputs 5 relay outputs Size 2 analog outputs 10V@100mA 8 Universal Inputs 10k therm, contacts, 4-20ma, 0-5V, 0-10V 112.0mm 48.0 mm Operating range Supply voltage Power consumption Relay contacts -30~70 C(-22~158 F) / 0 to 99% RH 12~24VAC/DC ±20%, 50-60Hz 100mA at 12VDC 5 relays, 2A @ 24VAC UL File No.: E169380 40.0mm Plastic Housing Enclosure rating Protocols Flammability rating UL 94 file E56070 IP31 Bacnet MSTP and Modbus RTU 83.8mm 60.0mm 33.2mm Baudrate 9600, 19200, 38400, 57600, 115200 Temperature sensor 10K thermistor ±0.5 C Setup Software Free, no licensing, open source 80.5 mm 21.0mm Wiring Diagram GND XFORMER 24 VAC - OUT RS485 TSTAT 8 BACKPLATE 15-24V AC/DC 8 UNIVERSAL INPUTS TEMPERATURE FILTER SWITCH OCCUP SENSOR FAN STATUS WINDOW CHANGEOVER PRESSURE SENSOR AIR FLOW 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Al1 Al2 Al3 Al4 Al5 Al6 Al7 Al8 RS485 POWER KCOM K1 K2 K3 K4 K5 AO1 AO2 15 16 17 18 19 20 21 22 23 24 25 26 27 28 FANS HEAT COOL PUMPS VALVES 24VAC 0-10V 24VAC 0-10V HEAT PUMP FAN COIL AIR HANDLER HYDRONICS MODULATING VALVES MODULATING DAMPERS 5 RELAY OUTPUTS 2 ANALOG OUTPUTS 02

Approvals Relay Plastic Enclosure Highlights PCB UL File No.: E169380 PA66 UL 94 V0 file E56070 FR-4 Epoxy Glass Cloth UL E479892 Tstat8 Bacnet Thermostat Wire Routing Terminal Block PA66 UL 94V-0 Software 8 analog inputs,2 analog inputs;5 digital outputs Industry standard Bacnet & Modbus protocols User screen displays Day at home, work time, night at home, sleep, holiday 3 PID controllers Bacnet Objects Device Object identifier;object name;object type;vendor name;vendor identifier; Model name;firmware revision;application software version; Protocol version;protocol revision;object list;max apdu length accepted; Segmentation supported Analog input Analog output Analog value Binary output Object identifier;object name;;object type;present value; Out of service;units Object identifier;object name;;object type;present value; Out of service;units;priority array Object identifier;object name;;object type;present value; Out of service;units;priority array Object identifier;object name;;object type;present value; Out of service;units;priority array;polarity;relinquish default;active text; Inactive text 03

Tstat8 Bacnet Thermostat Part Number Scheme Tstat8 OCC W/B Code Tstat8 Thermostat Code Code W B White color Black color Basic model temperature and clock H Humidity OCC Occupancy sensor 220 220V ZIG Zigbee Highlights Self reset fuses Mount on electrical box or surface mount Pluggable base Jack to network Mounting screw Advanced Menu Item Details They have several advanced menu items which can be adjusted in the field to suit the application and tune the operation of the thermostat. Generally speaking, all the parameters are set up at the factory on an order-by-order basis and will give satisfactory results out of the box. Thermometer Heating Fan 64.5 SET FAN SYS 20.0 Med Auto Cooling F Scroll Bar Specify displayed items and order,register 564 Actual temp display Occupied/Unoccupied Day/Night Last menu item Decrease value Next menu item Increase value 04

LCD Screen Display Tstat8 Bacnet Thermostat 1.When you press or, it will increase or decrease the set point value. The value will flash two times, then it will confirm the setting automaticlly. 2016.09.07 64.5 SET FAN SYS 3:50 PM 25.0 Med Auto F 2016.09.07 64.5 SET FAN SYS 3:50 PM 23.0 Med Auto F 2016.09.07 64.5 SET FAN SYS 3:50 PM 10.0 Med Auto F 2.In the normal mode, press both and at the same time.hold for several seconds,it will switch to the menu mode. Press or to scroll through the menu options such as 'Add', 'CAL', 'bau', 'UNITS' and many others. To change the values at a particular menu, press or,the chosen value will be stored automatically. To change the unit's address,scroll through the menu until you reach 'Add'. Press or to increase or decrease the unit's address from 1 to 254. To change the baudrate, locate 'bau' within the menu and use and to choose 19200 or 9600. 64.5 F Add 254 64.5 F CAL 13.1 64.5 F bau 19200 64.5 F C_F -C- Custom Enclosures and Logos Black Custom Logos 05

T3000 operation stat8 Bacnet Thermostat 1.Connect Tstat8 to PC by RS485, start T3000 software Click to scan Click to close 2.Click the button to scan, the following view will appear and close it as the picture indicates.when discussing Tstat8,close the view. Tstat8 detected Click to close when discussingtstat8 06

stat8 Bacnet Thermostat T3000 operation 3.Click Tstat8 log,then click input choices,click as below.,the T3000 will show all the information of it.to change name or Click to show input information Press range to different choices Click to change the name Tstst8 log 4.Click to do settings,you can see a tab below about setpoint and temperature. Click to do settings 07

T3000 operation stat8 Bacnet Thermostat 5.Click to do settings,you can see a tab below about parameter.click PIDs tables,you can find PIDs set Dialog. Click to do settings 08