Technical Information RIA15

Similar documents
Technical Information RIA16

Technical Information RIA16

EngyVolt RV12 and RV15

itemp TMT180 Technical information

4 â RIA251. Technical Information. Process display Digital loop powered display for ma current loops

Technical Information Promonitor NRF560

Operating Instructions Soliswitch FTE20

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

Process display RIA 251. Digital loop powered display for ma current loops. Application areas. Plant and machine construction.

Liquipoint T FTW31, FTW32

Operating Instructions

WirelessHART Adapter SWA70

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Technical Information Fieldgate SFG500

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Technical Data. General specifications. Rated operating distance s n 3 mm

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

Technical Information WirelessHART Adapter SWA70. Smart WirelessHART interface module with power supply for field devices. Products Solutions Services

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication

Liquipoint T FTW 31, FTW 32 Level limit switch for multiple point detection in conductive liquids

Technical Information WirelessHART Fieldgate SWG70

Level sensor Stainless steel version Model RLT-1000, for industrial applications

2 Device description. 2 Device description 2.1 Function. 2.1 Function. 2.2 Intended use. 2.3 Device versions

Technical Information Memobase Plus CYZ71D

Technical Information Memobase Plus CYZ71D

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

CombiView DFON Graphical display

Technical Information Minicap FTC260, FTC262

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

5 Fieldbus Technology

Flow Measurement SITRANS F C

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

Technical Information HAW562

RA33. Technical Information. Batch controller For the batching and dosing of mass and volume

SITOP in the SIMATIC Design

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

THE BARRIER and the Universal Barrier Cabinets from Pepperl+Fuchs

Technical Information WirelessHART Adapter SWA70. Smart WirelessHART interface module with power supply for field devices. Products Solutions Services

Product type designation. Control elements. Installation type/mounting

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

Flow Measurement SITRANS F C

Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication

Technical Information Liquipoint FTW23

Online data sheet TBS-1BSGT3506FM TBS TEMPERATURE SENSORS

Series 3730 Electropneumatic Positioner Type

DINALOG A 144 x 36 A1400 Light-Strip Indicator

Series 3731 Type Electropneumatic Ex d Positioner with HART communication

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Electropneumatic Positioner Type and Type with HART communication

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

ABL1REM24062 regulated SMPS - single phase V input - 24 V output W

Assembly. max Example: 2-wire connection IH More connection types see section electrical connections. Auxiliary voltage.

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail

Flow Measurement SITRANS F M

Temperature process values at a glance

UFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Redundancy unit CP-A RU

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

SITOP 3-phase 24 V DC, 20 to 40 A

LineMaster 100. Continuous-line Recorder. ABB Instrumentation 10/ EN

PanelView Plus/VersaView CE Terminals and Display Modules

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

Minilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values

T EN TROVIS Electropneumatic Positioner

SIY. Features. PC-Programmable Signal Isolator/Converter

Flow Measurement SITRANS F M

ABL1REM Main. Rated power in W. Power supply output current V. <= 100 Aat 230 V AC. 2.5 Aat 240 V

ExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)

Reed sensor For bypass level indicators Model BLR

Technical Information EngyCal RS33

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

TMT470L Temperature Transmitter

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

Room unit with PPS2 interface

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

SEM310 SEM310X HART UNIVERSAL TEMPERATURE TRANSMITTER

Separating and protective. Separating and protective instruments. VEGATRENN 149AEx Separator type KFDO Barrier type Product Information

Series 3730 Type Electropneumatic Positioner

Safety Instructions Cerabar S PMP71, PMP75

Transcription:

T004K/09/EN/04.4 759844 Products Solutions Services Technical nformation RA5 Loop-powered 4 to 0 ma with optional HART communication Compact with very low voltage drop for universal use to display 4 to 0 ma/hart signals Application Display of 4 to 0 ma measured values or optionally up to four of a sensor's HART process variables in all industries Use as primary or secondary HART master Panel-mount housing or field housing as local display Scalable display value our benefits No external power supply required Voltage drop V (HART.9 V) 5-digit measured value display with 7 mm (0.67 in) digit height with dimension and bar graph; background lighting can be activated Minimal installation depth Easy -key operation for configuring the device nternational approvals ATEX, ECEx, FM, CSA SL interference freeness acc. to EN 6508 GL marine approval

RA5 Function and system design Measuring principle The RA5 is integrated in the 4 to 0 ma or HART loop and transmits the measuring signal or HART process variables in digital form. The does not require an external power supply. t is powered directly from the current loop. The device meets the requirements of the HART Communication Protocol Specifications and can be used with devices with HART Revision 5.0. The LC display is easy to read even in bright sunlight and enables 5-digit, scalable measured value display. n addition to measured value display, the associated value dimension and a bar graph can be easily configured with simple -key operation. The device can also be operated with backlighting where necessary. n such cases pay attention to the higher voltage drop. Measuring system Zone 0,, Zone, Zone, RA5 as field and panel display A00895-EN nput Voltage drop Standard device with 4 to 0 ma communication Device with HART communication Display lighting.0 V.9 V additionally.9 V HART input impedance Rx = 40 kω Cx =. nf Measured variable Measuring range The input variable is either the 4 to 0 ma current signal or the HART signal. HART signals are not affected. 4 to 0 ma (scalable, reverse polarity protection) Max. input current 00 ma EndressHauser

RA5 Power supply Terminal assignment NOTCE SELV / Class device The device may only be powered by a power unit with an energy-limited circuit in accordance with EC 600-: 'SELV or Class circuit'. Device destroyed if current too high Do not operate the device at a voltage source without a current limiter. nstead, operate the device only in the current loop with a transmitter. Terminal Description Positive connection, current measurement - Negative connection, current measurement (without backlighting) Negative connection, current measurement (with backlighting) Auxiliary terminals (electrically connected internally) Functional grounding: Panel-mounted device: Terminal on the rear of the housing Field device: Terminal in the housing Connection 4 to 0 ma Connection without backlighting Connection with backlighting Connection with transmitter power supply and transmitter - - - Transmitter power supply A007704 A007705 Transmitter power supply Connection with transmitter power supply and transmitter using the auxiliary terminal - - - Transmitter power supply A007706 A007707 Transmitter power supply Connection with PLC and transmitter - - A00970 A0097 PLC PLC Connection without transmitter power supply directly in the 4 to 0 ma circuit - - 4 to 0 ma power source A007708 A007709 4 to 0 ma power source EndressHauser

RA5 HART connection Circuit diagram / Description -wire sensor with and loop power supply, without backlighting R s DC A009567 Sensor Power supply HART resistance -wire sensor with and loop power supply, with backlighting R s DC A009568 Sensor Power supply HART resistance 4-wire sensor with and loop power supply, without backlighting 4 A009570 HART resistance Current meter Sensor 4 Power supply 4-wire sensor with and loop power supply, with backlighting 4 A00957 HART resistance Current meter Sensor 4 Power supply 4 EndressHauser

RA5 Circuit diagram / Description Current output with and actor (e.g. actuator valve), without backlighting A00957 Actor Power supply Current output Current output with and actor (e.g. actuator valve), with backlighting A009574 Actor Power supply Current output Multi-drop -wire sensors with process display unit and loop power supply R s DC A009575 Sensors Power supply HART resistance Multidrop -wire sensors with process display unit and loop power supply, with backlighting R s DC A0097 Sensors Power supply HART resistance EndressHauser 5

RA5 Circuit diagram / Description -wire sensor with and active barrier RNN as loop power supply R s RNN O O- R A009576 Sensor HART primary master HART resistance The HART communication resistor of 0 Ω in the signal line is always necessary in the case of a low-impedance power supply. t must be installed between the power supply and the display unit. A HART communication resistance module is available as an accessory ( ). Connection with optional HART communication resistance module Wiring / Description -wire sensor with and loop power supply, without backlighting R s DC A00089 HART communication resistance module Sensor Power supply -wire sensor with and loop power supply, with backlighting R s DC A000840 HART communication resistance module Sensor Power supply 6 EndressHauser

RA5 Wiring / Description 4-wire sensor with and loop power supply, without backlighting A00087 HART communication resistance module Power supply 4-wire device Sensor 4-wire sensor with and loop power supply, with backlighting A00088 HART communication resistance module Power supply 4-wire device Sensor Supply voltage The display unit is loop-powered and does not require any external power supply. The voltage drop is V in the standard version with 4 to 0 ma communication,.9 V with HART communication and an additional.9 V if display lighting is used. Performance characteristics Reference operating conditions Reference temperature 5 C±5 C (77 F±9 F) Humidity 0 to 60 % relative humidity Maximum measured error nput Range Measured error of measuring range Current 4 to 0 ma Over range up to ma ±0. % Resolution nfluence of ambient temperature Warm-up period Signal resolution > bit < 0.0 %/K (0.0 %/ F) of measuring range 0 minutes EndressHauser 7

RA5 nstallation Mounting location Panel housing The device is designed for use in a panel. Required panel cutout 45x9 mm (.77x.6 in) Field housing The field housing version is designed for use in the field. The unit is mounted directly on a wall, or on a pipe with a diameter of up to " with the aid of an optional mounting bracket. An optional weather protection cover protects the device from the effects of weather conditions. Orientation Panel housing The orientation is horizontal. Field housing The device must be mounted in such a way that the cable entries point downwards. Environment Ambient temperature range Storage temperature Climate class Altitude Degree of protection Electromagnetic compatibility 40 to 60 C ( 40 to 40 F) At temperatures below 5 C ( F) the readability of the display can no longer be guaranteed. 40 to 85 C ( 40 to 85 F) EC 60654-, Class B Up to 5 000 m (6 400 ft) above MSL in accordance with EC600- Panel housing P65 at front, P0 at rear Field housing P66, NEMA4x (aluminum housing) nterference immunity: As per EC66 (ndustrial Environments) / NAMUR NE Maximum measured error < % of MR nterference emission: As per EC66, Class B Electrical safety Class, overvoltage protection category, pollution degree 8 EndressHauser

RA5 Mechanical construction Design, dimensions Panel-mount housing 09.75 (4.) 48 (.89) 4.75 (.68) 96 (.78) 7 (.46) 4.5 (0.8) mm (in) 89.5 (.5) Dimensions of the panel housing A0077 Required panel cutout 45x9 mm (.77x.6 in), max. panel thickness mm (0.5 in). Field housing (5.6) 55.5 (.9) 06.5 (4.9) 8.5 (.) mm (in) Dimensions of the field housing incl. cable glands (M6) A0077 Weight Panel-mount housing 5 g (0.5 lb.) Field housing Aluminum: 50 g (.5 lb) Plastic: 00 g (0.66 lb) Materials Panel-mount housing Front: aluminum Rear panel: polycarbonate PC Field housing Aluminum or plastic (PBT with steel fibers, antistatic) EndressHauser 9

RA5 Operability Local operation 4 5 8 7 6 4 Display and operating elements of the Symbol: operating menu disabled Symbol: error Symbol: warning 4 Symbol: Communication active (only for HART option) 5 Operating keys "-", "", "E" 6 4-segment display for unit/tag 7 Bar graph with indicators for under range and over range 8 5-digit 7-segment display for measured value, digit height 7 mm (0.67 in), display range -9999 to 99999 A00779 The device is operated with the operating keys on the front of the housing. The device setup can be disabled with a 4-digit user code. f the setup is disabled, a padlock symbol appears on the display when an operating parameter is selected. A00776 A00774 Enter key; calling up the operating menu, confirming the option/setting parameters in the operating menu Selecting and setting values in the operating menu; pressing the - and keys simultaneously takes the user back up a menu level. The configured value is not saved (ESC) A00775 Certificates and approvals CE mark Ex approval Functional safety Marine approval HART communication The measuring system meets the legal requirements of the EU Directives. EndressHauser confirms that the device has been successfully tested by applying the CE mark. nformation about currently available Ex versions (ATEX, FM, CSA, etc.) can be supplied by your EH Sales Center on request. All explosion protection data are given in a separate documentation which is available upon request. SL interference freeness according to EN6508 (optional) GL marine approval (optional) The display unit is registered by the HART Communication Foundation. The device meets the requirements of the HART Communication Protocol Specifications, May 008, Revision 7.. This version is downwards compatible with all sensors/actuators with HART versions 5.0. 0 EndressHauser

RA5 Other standards and guidelines EC 6059: Degrees of protection provided by enclosures (P code) EC 600-: 00 cor 0 Safety requirements for electrical equipment for measurement, control and laboratory use EC 66 series: Electromagnetic compatibility (EMC requirements) NAMUR NE, NE4 Association for Standards for Control and Regulation in the Chemical ndustry Ordering information Detailed ordering information is available from the following sources: n the Product Configurator on the EndressHauser web site: www.endress.com Choose your country Products Select measuring technology, software or components Select product (picklists: measurement method, product family etc.) Device support (right-hand column): Configure the selected product The Product Configurator for the selected product is opened. From your EndressHauser Sales Center: www.addresses.endress.com Product Configurator - the tool for individual product configuration Up-to-the-minute configuration data Depending on the device: Direct input of measuring point-specific information such as measuring range or operating language Automatic verification of exclusion criteria Automatic creation of the order code and its breakdown in PDF or Excel output format Ability to order directly in the EndressHauser Online Shop Accessories Various accessories, which can be ordered with the device or subsequently from EndressHauser, are available for the device. Detailed information on the order code in question is available from your local EndressHauser sales center or on the product page of the EndressHauser website: www.endress.com. EndressHauser

RA5 Device-specific accessories Protective cover 6 0 (7.9) 98 (.7) (.48) 05 (8.07) 5 Dimensions of the protective cover, dimension unit mm (in) A0077 Mounting kit for wall/ pipe mounting 80 (.5) 8 (.) 5 (4.5).5 (0.45) 6 Dimensions of the mounting bracket, dimension unit mm (in) A00780 HART communication resistance module 54 (.) (0.87) 8. (0.) 4 (0.94) (.) 7 A000858 Dimensions of the communication resistance module, dimension unit mm (in) Documentation System Components and Data Managers - Solutions for the loop: FA0006K/09 Operating instructions Process display unit RA5: BA007K/09 Operating instructions Process display unit RA5 with HART communication: BA070K/09 Ex Safety nstructions: ATEX/EC ()G Ex ia C T6: XA008R/09 EndressHauser