SINAMICS G120 Firmware Version V4.7 SP6 HF1 siemens.com/answers
SINAMICS G120 Firmware Version V4.7 SP6 HF1 New Power Modules supported 2 New motors supported/ updated 5 Modified commissioning behavior 10 Free function blocks with G120C 13
V4.7 SP6 HF1 New Power Modules supported CU230P-2 CU240B-2 CU240E-2 CU250S-2 PM240-2 Power Module FS F supported CU240E-2 CU250S-2 including Safe Torque Off (STO, SIL3) via Power Module terminals Product note @Industry Online Support: SIOS Safety Integrated Function Manual @Industry Online Support: SIOS CU230P-2 PM330 FS JX Power Modules supported (April 2016) Continuous expansion of Power Module hardware support
SINAMICS G120 Firmware Version V4.7 SP6 HF1 New Power Modules supported 3 New motors supported/ updated 4 New steel plant motors supported 5 Reluctance motors with 60Hz/ 87Hz 6 PT1000 temperature sensor 7 Other expansions 8 Modified commissioning behavior 10 Free function blocks with G120C 13
V4.7 SP6 HF1- SINAMICS G120 converters and the steel plant motors 1PC10 from a coordinated drive system G110M G120C CU230P-2 CU240B-2 CU240E-2 CU250S-2 CU240D-2 CU250D-2 ET200pro FC-2 Advantages Features/functions Non-ventilated (IC410) and ventilated (IC411) versions Benefits Wide flexible use Special insulation system up to 500VAC when connected to the G120 converter Converter motor acc. to IEC 60034-25 Simple commissioning using predefined parameters in the SINAMICS G120 High voltage strength and therefore a long service life No additional Energy Label is required (Europe, Asia, America) Commissioning, maintenance time and costs are reduced Use with SIMOGEAR geared motors is planned Seamless solution based on harmonized and coordinated products from a single source
V4.7 SP6 HF1- SIMOTICS 1FP1 reluctance motors supported (rated powers from 5.5 30 kw) CU230P-2 PM240-2 Firmware Highlights Feature/function Benefits The motor is selected using a code number High starting and accelerating torque using the adapted vector control Flux reduction using vector control Fast and straightforward commissioning Speed is precisely maintained, even without encoder Load surges are quickly corrected Additional energy-saving by optimizing the system for the specific operating point NEU NEU Operation with 60 Hz power Operation with 87 Hz power Product note @Industry Online Support: SIOS For use in 60Hz power systems High speed without field weakening is possible Use of the overload capability of the synchronous reluctance motors SIMOTICS reluctance motors with SINAMICS inverters set themselves apart as a result of the high energy efficiency, high dynamic performance, user friendliness and functionality.
V4.7 SP6 HF1- Support of PT1000 temperature sensor G110M G120C CU230P-2 CU240B-2 CU240E-2 CU250S-2 CU240D-2 CU250D-2 ET200pro FC-2 Temperature determination with PT1000 New characteristic with PT1000 interpretation Expansion of parameter p0601 with PT1000 (default: no sensor) 0: No sensor 1: PTC alarm & timer 2: KTY84 4: Bimetallic NC contact alarm & timer 6: PT1000 SMI/DQI-motors will be supported automatically (CU250S-2) Benefits of PT1000 PT1000 is comparable with KTY PT1000 is a widespread component with standardized characteristic curve (IEC 60751) There are several manufacturers No new hardware for evaluation is necessary (only adaption of characteristic curve in software) Characteristic curve distinctly easier (linear resistance) Product note @Industry Online Support: SIOS KTY84 temperature sensor will no longer by produced by manufacturer NPX. New motors come with PT1000 temperature sensor supported with V4.7 SP6.
SINAMICS G120 version 4.7 SP6 HF1 Other expansions Function Support of new 1LE motors (motor database extended) New parameter p4621[0...n] - motor temperature sensor configuration - PTC short-circuit monitoring can be De-activated G110M G120C CU230P-2 CU240B-2 CU240E-2 CU250S-2 CU240D-2 CU250D-2 ET200 ProFC-2 Customer benefits Easy commissioning of standard motors because of predefined parameters Nuisance failure trips caused by tolerances of electronic equipment can be deactivated
SINAMICS G120 Firmware Version V4.7 SP6 HF1 New Power Modules supported 3 New motors supported/ updated 5 Modified commissioning behavior 9 Free function blocks with G120C 13
V4.7 SP6 HF1- Modified commissioning behavior G120C CU230P-2 *) CU240B-2 *) CU240E-2 *) CU250S-2 *) *) only with PM240/ PM240-2 For simplified commissioning and increased degree of ruggedness of closed-loop motor control, a suitable application class can be selected with V4.7 SP3 Product note @Industry Online Support: SIOS Standard Drive Control Dynamic Drive Control Expert To ensure reliable, stable operation, motor data identification (Motor-ID) is essential. Features/functions V4.7 SP6 HF1 PM240 FS D default setting: Dynamic drive control Motor-ID default configuration: p1900=2 (measurement at standstill) Details see next slide Motor-ID default configuration can be changed within standard drive control mode The engineering systems informs the user about running Motor-ID BOB (V4.7 SP6 HF1) IOP from V1.6 SP2 (03/2016) STARTER V4.4 SP1+SSP V4.7.6 Startdrive V13 SP1+HSP V4.7.6 Benefits Increased flexibility and usability Product note @Industry Online Support: SIOS Firmware Download @Industry Online Support: SIOS Operating Instructions @Industry Online Support: SIOS
SINAMICS G120 Modified commissioning behavior Motor data identification Default setting G120C CU230P-2 *) CU240B-2 *) CU240E-2 *) CU250S-2 *) *) only with PM240/ PM240-2 V4.7 V4.7 SP3 V4.7 SP6 HF1 Commissioning Mode Default Setting Motor data identification No application classes (only Expert) No Motor-ID p1900 = 0 e.g. with unreliable Motor data (external Motor) SINAMICS application classes (Standard or Dynamic Drive Control, Expert) Motor-ID: p1900 = 12 measurement at standstill with a direct transition into operation Motor-ID: p1900 = 2 measurement at standstill Commissioning Phase First Start- Command 1. 12 2 1. 1. 2. Motor data identification Setpoint ca. 15 30 s ca. 15 30 s Motor speed Motor turns with bad behavior, gets hot or even does not turn Motor in standstill Motor turns Motor in standstill Motor turns
SINAMICS G120 Firmware Version V4.7 SP6 HF1 New Power Modules supported 3 New motors supported/ updated 5 Modified commissioning behavior 10 Free function blocks with G120C 12
G120C: Free function blocks come with V4.7 SP6 HF1 NEW G110M G120C CU230P-2 CU240B-2 CU240E-2 CU250S-2 CU240D-2 X CU250D-2 X ET200pro FC-2 Free function blocks (FFB) SINAMICS G120C with V4.7 SP6 HF1a offers a comprehensive block library: Closed-loop control blocks (PI controller, smoothing elements, limiters, etc.) Arithmetic blocks (adders, dividers, max/min evaluator, etc.) Logic blocks (switch-on - switch-off delay, AND, XOR, counter, etc.) and... The FFBs are interconnected with one another and with the basis functions using BICO technology Setpoints Digital input FFBs Functions x,y,z Ramp-function generator FFBs Speed controller Profibus / control Analog input 10% + y AR Tup ER AR ER Tdn t 0% n set Speed controller Profibus / setpoint The free function blocks permit configurable signal processing in the Inverter. Now also available in SINAMICS G120C
G120C: Free function blocks come with V4.7 SP6 HF1 NEW G110M G120C CU230P-2 CU240B-2 CU240E-2 CU250S-2 CU240D-2 X CU250D-2 X ET200pro FC-2 Functional scope of the FFBs 25 freely interconnectable block types according to the adjacent overview table Interconnection using BICO technology Logic, arithmetic, data storage, closed-loop control blocks As a consequence: Open-loop control functionality and technology with limited flexibility directly in the drive Additional functionality can be simply realized using preconfigured, but limited blocks Example for showing the FFBs in the documentation https://support.industry.siemens.com/cs/ww/e n/view/85168215 The FFBs are limited regarding the absolute quantity The computing intervals (sampling times) can be selected. These blocks are NOT multiinstance capable
Thank you for your attention! Product management drives Frauenauracher Str. 80 91056 Erlangen siemens.com/answers