IE/PB LINK PN IO. PROFINET applications

Similar documents
Supplementary Components Network transitions

PA ROUTERS. The following criteria can be applied when choosing the network transition:

CP ADVANCED. Function

CP BACNET Function

CPU 319F-3 PN/DP. Page 1682 Mar 2008 Siemens ITS

PAS 300, PROFIBUS Slave Interface Module

Application for Process Automation

Data sheet CPU 015PN (015-CEFPR01)

IM IM in the RS485 variants features: 9-pin Sub-D socket for connection to PROFIBUS DP

TELESERVICE. Teleservice with TS Adapter IE. Page 1864 Mar 2008 Siemens ITS

Data sheet VIPA CPU M13C (M13-CCF0000)

Siemens AG ES AH02-0AE0 6ES BH02-0AE0 6ES CH02-0AE0

General information. Supply voltage. Input current

General information. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage

General information. Display. Control elements. Supply voltage

CPU 317F-2 DP. Page 1603 Mar 2008 Siemens ITS

General information. Supply voltage. Input current

General information. Configuration control. Control elements. Supply voltage. Input current. Power. Power loss. Memory

General information. Supply voltage. Input current

General information. Supply voltage. Input current

NETL ink gateways. Ethernet gateways WLAN gateways High-speed USB gateways

General information. Display. Control elements. Supply voltage

Product type designation

General information. Configuration control. Display. Control elements. Supply voltage

Modular Control System KS VARIO

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

SIMATIC NET. S7-CPs for PROFIBUS. CP Extended for PROFIBUS. Manual Part B4

Parameterizable properties The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7:

Data sheet CPU 015PN (015-CEFPR00)

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

TIM 3V- IE ADVANCED. Function

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

6ES7151-8AB01-0AB0. 5/18/2011 Siemens Industry IA/DT/BT Service&S. siemens.com/ww/llisapi.dll?func=csl 1/10 ET200S, IM151-8 PN/DP CPU, 192 KB

PROFIBUS and Integrated Safety architectures in Ex areas

Fieldbus slave modules w/o I/Os

Data sheet SLIO CPU 015PN (015-CEFPR01)

Application on Communication

Data sheet CPU 013C (013-CCF0R00)

General information. Supply voltage

Data sheet CPU 315SN/PN ECO (315-4PN33)

General information. Supply voltage. Input current

Control block CPX-CM-HPP

The PROFIBUS and PROFINET Company. COMbricks Modules. Copyright 2013 PROCENTEC. All rights reserved.

Structure and Function

SCE Training Curriculum for Integrated Automation Solutions Totally Integrated Automation (TIA)

Basics of setting up. PROFIBUS-PA networks. Martin Ruck Siemens. Jason Nicholl Phoenix. Kris Hardaker United Utilities

SINAMICS S120. Communication. Communication 2/7. Overview

SIMATIC ET 200SP and ET 200MP

FAQ 12/2015. PROFINET IO Communication.

Technical data. General specifications. Functional safety related parameters B 10d Electrical specifications Operating voltage U B

Quick Start Guide PN/CAN Gateway Layer 2. Version. 2 en. ab FW

Product type designation. General information. Supply voltage. Input current. Power loss

Communication Bus System

SIMATIC S7-400, CPU KB WORKING MEMORY (384 KB CODE, 384 KB DATA) 1. INTERFACE MPI/DP 12 MBIT/S 2.IF PROFIBUS DP, 3.

SIMATIC NET. Industrial Ethernet / PROFIBUS IE/PB LINK PN IO. Preface. Application and properties. LEDs, connectors, buttons 2

Data sheet VIPA CPU 214PG (214-2BE03)

Training Document for Integrated Automation Solutions Totally Integrated Automation (TIA)

Supply voltage. Input current. Power loss. Memory. Battery. CPU processing times

PROFINET The leading communication system

Data sheet VIPA CPU 214NET PG (214-2BT13)

PROFINET The industrial Ethernet standard. This is my way

SIMATIC S Central processing units

Control Circuit Components

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 130 a at 40 C Mission Time (T M ) L 10

CPU 412H. Function. Parameterizable properties

FAQ Communication over PROFIBUS

General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

SIMATIC S Update to the S System Manual, edition 03/2014 Product Information

CPU 412. Function. Programmable properties

Product type designation. General information. Supply voltage

Why can you not transfer the HMI configuration to the panel? - PROFIBUS Connection - FAQ 03/2014

IndraControl S67. Fieldbus coupler PROFINET

UK PROFIBUS. Group. 20th Anniversary Celebration Conference. Karsten Schneider PI Chairman. UK, June 2013

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Programming package STEP 7 V5.2 SP1 or higher with HSP 0126

Supplementary Components WirelessHART products

crio PN Installation Instructions V0.2/ COMSOFT

SIMATIC. Component based Automation - WinLC PN Addendum to WinAC Basis V3.0. Foreword. Introduction to CBA and WinAC PN 2. Routing with WinLC PN 3

SIPLUS CPU 313C-2DP. Function

GRASSO SYSTEM CONTROL

SCE Training Curriculum For Integrated Automation Solutions Totally Integrated Automation (TIA)

SIMATIC PCS 7 27 th September 2018 Stefan Goldhammer. Unrestricted Siemens AG 2018 SIEMENS AG/ PD PA AE SUP SPS

Product type designation. General information. Supply voltage. Input current. Power losses

Introduction to PROFIBUS for Process Automation

Technical Information Fieldgate SFG500

Simple - smaller - stronger SIMATIC ET 200SP. Unrestricted / Siemens AG All Rights Reserved.

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

Data sheet CPU 315SB/DPM (315-2AG12)

MGate 5102-PBM-PN Series

PROFIBUS. Connectors Repeaters FO Wireless system Communication

General. Remote I/O A4/1.

Data sheet CPU 315SN/NET (315-4NE12)

Data sheet CPU 315SN/NET (315-4NE12)

Training document for the company-wide automation solution Totally Integrated Automation (T I A)

System description SLIO

Quick Start Guide NETL ink Ethernet Gateways

EasyConnect PROFIBUS-Connector, 90

Product type designation. General information. CiR - Configuration in RUN. Input current. Power loss. Memory

Transcription:

IE/PB LINK PN IO PROFINET applications Protection of investment due to simple connection of PROFIBUS DP slaves to PROFINET IO controller Enables the use also in plants with PROFIsafe applications Independence from individual vendors through support of the PROFINET standard for distributed field devices Page 1955 Mar 2008 Siemens ITS

Configuration example of PROFIBUS and PROFINET PROFIBUS devices can be seamlessly integrated into PROFINET over the IE/PB Link PN IO as proxy. Applications in the case of vertical integration Worldwide access to data of the PROFIBUS stations via Industrial Ethernet and Internet for vertical integration Optimization of a plant from a central location Access to process data from all enterprise levels Loading of STEP 7 programs from a central location Configuration example of IE/PB Link PN IO as network transition from Industrial Ethernet to PROFIBUS for vertical integration Page 1956 Mar 2008 Siemens ITS

Function PROFINET PROFINET IO proxy; connection of PROFIBUS DP slaves to PROFINET IO controller with real-time property, according to PROFINET standard Additional functionality for vertical integration S7 routing permits cross-network PG communication, in other words, all S7 stations on Industrial Ethernet or PROFIBUS can be programmed remotely using the programming device. Access can be made to visualization data of S7 stations on the PROFIBUS from HMI stations on the Industrial Ethernet. Data record routing (PROFIBUS DP) Using this option, the IE/PB Link PN IO can be used as a router for data records that are forwarded to field devices (DP slaves). SIMATIC PDM (Process Device Manager) is a tool that creates data sets of this type for parameterizing and diagnosing field devices. Application: It is possible, for example, to use SIMATIC PDM (on the PC) on Industrial Ethernet to set parameters and run diagnostics for PROFIBUS PA field device over the IE/PB Link PN IO and DP/PA coupler. Page 1957 Mar 2008 Siemens ITS

The additional functions for vertical integration can also be used in an existing PROFIBUS application without PROFINET for connection to a higher-level Industrial Ethernet. In this case, the IE/PB Link PN IO is used as an additional DP-Master Class 2 on a PROFIBUS segment for linking to the Industrial Ethernet and offers the above functions. Diagnosis Extensive diagnostic options are available via STEP 7 or SNMP, including: Diagnosis of the assigned PROFIBUS field devices; using the IE/PB Link PN IO as a proxy, the connected DP slaves can be diagnosed in the same manner as PROFINET IO devices (even in the user program of the PROFINET IO controller) General diagnostics and statistics functions Connection diagnostics Diagnostic buffer Integration into network management systems through the support of SNMP V1 MIB-II Page 1958 Mar 2008 Siemens ITS

Configuration STEP 7 V5.4 or higher or the TIA Portal V11.0 is required for configuring the full functionalbscope of the IE/PB Link PN IO. For the IE/PB Link PN IO, STEP 7 automatically generates the necessary parameters, e.g. the ones that assign addresses, and all necessary routing information. The configuration data for PROFINET IO created with STEP 7 is saved on the IO controller. Attention must however be paid to the memory capacity. The initialization data for the Ethernet interface is backed up on the C- PLUG (Configuration Plug) swap media. The IE/PB Link PN IO can be swapped in the event of failure without a programming device, because the relevant user and configuration data is saved on the IO controller or on the C- PLUG. Technical specifications Data transmission rates Industrial Ethernet PROFIBUS Interfaces Connection to Industrial Ethernet 10BaseT/100BaseT Technical specifications Connection to PROFIBUS 10/100 Mbit/s autosensing 9.6 kbit/s to 12 Mbit/s incl. 45.45 kbit/s (PROFIBUS PA) RJ45 9-pin Sub-D socket Page 1959 Mar 2008 Siemens ITS

Connection for power supply 2-pin terminal block Voltage supply 24V DC (+/-5 %) Current consumption (at rated voltage) external from 24 V DC, max. 600 ma Power loss approx. 10 W Perm. ambient conditions Operating temperature 0 C + 60 C Transport/storage temperature - 40 C + 70 C Relative humidity, max. 95 % at +25 C Design Module format S7-300 construction Dimensions (W x H x D) in mm 80 x 125 x 120 Weight approx. 600 g Degree of protection IP20 Configuration Configuration software for PROFINET and STEP 7/NCM S7, V5.3 SP1 or higher additional functions Performance data PROFINET communication PROFINET IO performance data Number of DP slaves on the IE/PB Link PN IO 64 (PROFINET IO-Devices for PROFINET IO) Number of DP inputs, max. 2048 byte Number of DP outputs, max. 2048 byte Page 1960 Mar 2008 Siemens ITS