Installation Instructions Temperature transmitter TAA /00 06/2011

Similar documents
Operating instructions Electronic pressure sensor. PM205x /01 09/2011

Operating instructions Pressure sensor. PN50xx / / 2010

Operating instructions Electronic temperature sensor TN /00 04/2011

Operating instructions Control monitor for temperature sensors TR /00 04/2011

Pressure switch RE B/ Type HEDE10.../1/ Operating instructions

Operating instructions Memory plug E /02 11/2011

Operating instructions Programming and display unit PP / / 2010

Operating instructions Pressure sensor. PE30xx / / 2010

SM9000. Made in Germany

Operating instructions Pressure sensor. PN70xx / / 2012

DCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor

Operating instructions Pressure sensor. PN78xx / / 2010

Installation instructions Inclination sensor EC2019 EC / / 2013

This data sheet is only valid in association with the IL SYS INST UM E user manual.

TMT470L Temperature Transmitter

SM9000. Magnetic-inductive flow meter. Made in Germany

GFK-2415A March Type of sensor connection

Operating instructions Pressure sensor. PN70xx / / 2010

Temperature measurement TER8 Front-flush and low-invasive resistance thermometers

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental

AXL E IOL AO1 U M12 R

Temperature Switches

AI561 Analog Input Module

Encoders Absolute Singleturn Encoder Types A58CS8

Modular pressure transmitters for harsh environments DST P500, DST P507 and DST P550

AO561 Analog Output Module

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

DI572 Digital Input Module

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

MINI MCR-SL-PT100-UI-200

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

FL MC 2000E (SM40) LC

Electronic pressure switch with display Model PSD-4

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

NOVOTURN Multiturn-Sensor non-contacting. Series RSM2800 digital SSI, SPI

Digital Modules AS-i in IP20, 22,5 mm

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

NOVOHALL Rotary Sensor non-contacting. Series RSX-7900

DC561, digital input/output module,

Analog Modules AS-i, IP67, M12

DI561 Digital Input Module

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution

RMCN22BD Analog Converter ma - for Zelio Analog

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

Operating instructions Electronic pressure sensor. PI109x / / 2010

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

DC562, digital input/output module,

MINI MCR-SL-UI-2I(-SP)(-NC)

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Operating instructions Combined pressure sensor. PN22xx / / 2010

TRIO-DIODE/12-24DC/2X10/1X20

NOVOHALL Rotary Sensor touchless transmissiv. Series RFC4800 SSI, SPI, Incremental

QUINT-BUFFER/24DC/24DC/40

XUK8TAKSMM12 photo-electric sensor - XUK - diffuse - Sn 5m 1Q auto PNP/NPN

MINI-PS AC/10-15DC/8

XMLK006B2C21 pressure sensor XMLK bar - G 1/4A mA - DIN - set of 1

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

RAD-DAIO6-IFS. I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs. INTERFACE Data sheet.

MINI MCR-SL-UI-REL(-SP)

DS 201P. Electronic Pressure Switch. Pressure Port With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

NOVOTURN Multiturn Sensor non-contacting Series RSM2800 analog

AO523 Analog Input Module

Operating instructions. ProcessLine analogue module AC / / 2012

DX561 Digital Input/Output Module

Electronic timer CT-AHD.22

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster

VM series. features. web contents. code description. available models. inductive sensors. Cylindrical M12 in AC B H

Installation / Control / Monitoring Technique

Absolute Encoders Multiturn

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010

Operating Principle Capacitive proximity sensors

em4 Accessories Digital expansions

XMLR400M1P25 Pressure sensors XMLR 400bar - G 1/4-24VDC ma - PNP - M12

VAL-CP-1S-175. Extract from the online catalog. Order No.:

Thread length (overall length) material

Original operating instructions Fail-safe inductive sensor GG711S

TF501, TF521 Terminal Bases

Original operating instructions Fail-safe inductive sensor GI712S

MINI MCR-SL-PT100-UI(-SP)(-NC)

ABSOLUTE ROTARY ENCODER INTERBUS

Communications & Networking

Electronic Level Switch ENS 3000

TU531, TU532 Terminal Unit

Immersion Temperature Sensors

standard, short, preferential, top

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Electrical connection

XMLP200PD730 pressure transmitter - XMLP - 200psi - 1/4"18NPT V - M12 - set 1

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

Absolute Encoders Multiturn

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Proximity sensors SME-8, for T-slot Technical data Magnetic reed

SATEL-LP-AI4. I/O extension module, 4 analog current inputs. Data sheet. 1 Description

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

Inductive Cylinder Position Sensors

Transcription:

Installation Instructions Temperature transmitter TAA431 706042/00 06/2011

Contents 1 Functions and features...3 2 Installation...4 2.1 Addressing...4 2.2 Mechanical installation...4 2.3 Connection to the AS-i system...5 2.4 Installation and set-up / Operation...5 2.5 Slave profile...5 2.6 Representation of measured values by data bits D16...D1...6 2.7 Fault handling...6 2.8 Data bits...7 3 Technical data...8 4 Scale drawing...9 2

1 Functions and features The temperature transmitter operates as a single slave in the AS-i network (slave profile S-7.3.C). It detects the current system temperature, converts it into digital coded analog values and transfers these values to the control level (master, controller or host). Analog value representation Signed 16-bit value as two s complement value. The analog value transmission protocol is specified in the slave profile 7.3. A master of AS-i version 2.11 detects the slave automatically. The analog value transmission to slave profile 7.3 is then supported. Masters of AS-i version 2.0 require a special driver (additional function block, available as an accessory). Measuring range: -10...150 C / 14...302 F Measuring element: Pt 1000 to DIN EN 60751, class A Temperature resistance [min] 240 200 160 120 80 40 0 110 115 120 125 130 135 140 145 150 155 [ C] Maximum operation time depending on the medium temperature 3

2 Installation 2.1 Addressing You can address the sensor by using an addressing unit, the master or by means of the AS-i software of the host (the components must support AS-i version 2.11). Assign an address between 1 and 31. At the factory the address is set to 0. 2.2 Mechanical installation There are a number of possibilities: 1. Installation to G½ process connection. 2. Installation with E30016 (G ½) or E30024 (½ NPT) progressive ring fitting. 3. Installation with welding adapter E30055 (ball adapter) or E30056 (collar adapter). 4. Installation with E34110 clamp adapter for hygienic systems (A) and process adapter (B). Slightly grease the contact areas between the sensor and adapter using a lubricating paste which is suitable and approved for the application. For information on the installation with adapters / progressive ring fittings please refer to the instructions enclosed with the respective articles. standard applications hygienic systems 1 2 3 4 A B tightening torque: 30...50 Nm 4

2.3 Connection to the AS-i system Connect the sensor with the AS-i system by using the M12 connector. Voltage is supplied via the AS-i network. Wiring: Core colours of ifm sockets: 1 BN 1 = BN (brown), ASI+ 3 = BU (blue) 3 BU ASI Referring to UL: For use on a low voltage circuit with overcurrent protection in accordance with UL873 Tab. 28.1 or Imax = 100/Ub (Ub = voltage of the circuit). 2.4 Installation and set-up / Operation After mounting and wiring check whether the unit operates correctly. Indication at the sensor in the operating mode: LED green LED red ON = unit is then ready for operation ON = no communication FLASHING = internal fault is transferred to the master as periphery fault 2.5 Slave profile I/O Code [hex] 7 ID Code [hex] 3 Extended ID2 Code [hex] C ID1 Code code for temperature values [hex] 6 Slave address (factory setting) 0 5

2.6 Representation of measured values by data bits D16...D1 Overflow (measured value outside the value range), overflow bit is set 32767 Overrange (measured value is valid but outside the nominal range) 1500...1650 Nominal Range (measured value in the specified value range) -100...1500 Underrange (measured value is valid but outside the nominal range) -150...-100 Underflow (measured value outside the value range), overflow bit is -32768 set Representation of measured values following ID1 C 0.1 Increments min. 0.1 2.7 Fault handling Automatic fault handling according to AS-i version 2.1. Power-up: During power-up the data is marked faulty until a valid data transfer is guaranteed. After interruption of the data communication the watchdog function starts communication again. Data triple in wrong order: If a fault occurs, the sensor sets its data triples to 0 (invalid) and waits for a new triple sequence. 6

2.8 Data bits During one transmission cycle the following data is transferred in data triples. Extension Bits User Information Data Additional Information Bits E3 E2 E1 D16 D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 O V Only 1 measuring channel is used. The bits E3, E2 and E1 are always 0. The analog values measured are transferred via the data bits D1...D16 according to slave profile 7.3. Overflow-Bit Valid-Bit Overflow-Bit: O = 0: measured value is within the value range O = 1: measured value is outside the value range (above max. value for overload or below minimum value for overload) Valid-Bit: V = 0: measured value not valid V = 1: measured value valid 7

3 Technical data Operating voltage [V]... 18...31.6 DC (AS-i) Reverse polarity protection / overload protection Current consumption [ma]...< 25 Measuring range [ C / F]... -10...150 / 14...302 Measuring element...1 x Pt 1000 to DIN EN 60751, class A Accuracy...± 0.3 K (-10...150 C / 14...302 F) Resolution [ C / F]...< 0.05 / 0.09 Dynamic response (according to DIN EN 60751) [s]... T05 = 1 / T09 = 3 Housing material... stainless steel 316L / 1.4404; stainless steel (304S15); stainless steel (303S22); PA Materials (wetted parts)... stainless steel 316L / 1.4404 Max. medium temperature [ C]... 150 C (< 40 min.) Operating temperature [ C]... -25...+70 Storage temperature [ C]... -40...+100 Permissible overl. pressure [bar]...300 1) Protection... IP 69K Protective class...iii Shock resistance [g]... 50 (DIN / IEC 68-2-27, 11ms) Vibration resistance [g]... 20 (DIN / IEC 68-2-6, 10-2000 Hz) EMC EN 61000-4-2 ESD:... 4 / 8 KV EN 61000-4-3 HF radiated:... 10 V/m EN 61000-4-4 Burst:...2 KV EN 61000-4-5 Surge:...0.5 / 1 KV EN 61000-4-6 HF conducted:... 10 V 1) only applies to the sensor; for installation in adapters the indications in the adapter data sheet shall apply 8

4 Scale drawing 30 M12x1 14,7 LED G1 2 27 190,5 52,8 123 87,5 47,5 18,3 8,2 10 9