GosHawk II COMMUNICATIONS

Similar documents
Getting started with your DGH module:

QUICK START. DevCom2000 User Manual

USB-COMi-TB USB to Industrial Single RS-422 / 485 Adapter Manual. Specifications and Features

This 4-port RS-422/485 Adapter is provided with an external switching power adapter in the package.

The following steps will allow you to install and quickly begin using DevCom2000:

Galaxy ACCeSS Lite Downloader

The following steps will allow you to install and quickly begin using DevCom:

Installing LE History Record Reader program software.

Talk Light Time Manager User Instructions

CORD-XL Dual-Channel Electronic Chart Recorder User s Manual

Product Manual. 2 Port USB to RS-422 /485 Optical Isolated Adapter. Coolgear, Inc. Version 1.1 March 2018 Model Number: USB-2COMi-Si-M

LVX Control Unit. Features:

FSA-CU Configuration Utility Programming Guide

The following steps will allow you to install and quickly begin using DevCom:

Introduction & Specifications of Hi-Speed USB to Industrial Dual Ports RS-422/485 Adapter

USB-16COMi-M 16-Port RS-422/485 USB Serial Adapter User Manual. Features and Specifications. Power Supply

HRM-0800 Instruction Manual

SECTION 3 NV9 USB MANUAL SET

SpecWare 9 Pro and Basic Software Quick Start Guide

BCOM-USB Device. User Manual.

Docking Station DS-U4WEB with web server version 1 Instruction Manual

SpecWare 9 Pro and Basic QUICK-START GUIDE

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

User Manual A08. User Manual

User s Guide. Ethernet Module for Barcode Printer

Environdata FA ma Converter Guide

Technical data. General specifications. Indicators/operating means

C-Bus Telephone Interface Training Manual V T Series

Serial Communication Converters & Adapters Instruction Manual

RS-422/485 PCIe Card

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

RS-422/485 PCI Card User Manual Ver All brand names and trademarks are properties of their respective owners.

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2

YourBell INEXPENSIVE, RELIABLE USB PRODUCTS.

DYB2200 INEXPENSIVE, RELIABLE USB PRODUCTS.

Product Manual. USB to Optical Adapter Industrial Isolated RS- 232/422/485. Coolgear, Inc. Version 2.1 December 2018 Model Number: USB-COMi-Si-M

SPMS SmartPage Messaging System

DIABLOSPORT PREDATOR REVISION UPDATE INSTRUCTIONS

Installation Guide of Hi-Speed USB to Industrial Single RS-422/485 Adapter

Bluetooth Connection Kit

Please take the time now to check the contents of your package: HPS12U Print Server One CD-ROM Quick Installation Guide One power adapter

Prizm Mux Monitor (PMon) User Manual. March 13, Rev. 2.1

Flex Series User Guide

Canlan INSTALLATION MANUAL

User Manual for VE GSM Modem

CPU ONE PLC PLC USER S MANUAL

Up to two expansion cards can be added; these cards may either add an additional 4 analogue or 8 digital inputs.

USB-Link 2 Technical Guide

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Cheetah16/32/64 Setup Guide

ECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.

FULMATIC 7 SILVER SERIES PLC PLC USER S MANUAL

Sauter Systems

Installation Guide of Hi-Speed USB to Industrial I/O Adapter

DATRAN XL4 PLUS RTU Quick Start Guide

Copyright Extract from Conditions of Sale Safety Warning

NMEA 2000 to NMEA 0183 Gateway NGW-1-ISO. Installation Manual

CompactFlash/SDIO Connection Kit with Bluetooth Wireless Technology

A TECHNICAL INFO A. External GSM AT420 DATE :

Trouble shooting the DeskCNC controller:

USB-Link Technical Guide

2001 by NEC America. All Rights Reserved. Printed in U.S.A.

SMARTLINE WIRELESS INTERFACE SYSTEM INSTALLATION MANUAL

MTX-D Ethanol Content and Fuel Temperature Gauge User Manual

Windows 8 / 7 CONTENTS. USB to RS-422 Converter. Part Number: USB FEATURES. 2 SPECIFICATIONS. 2 CONNECTIONS.. 3

FT2 View Instruction Manual

USER MANUAL UPDATED

CommLink IV Technical Guide

Bluetooth TO Serial CONVERTER E-P132-B

17 Hatidhar st. Ra anana 43665, Israel Fax: Tel: UDEC-1. Universal Debug Center User Manual & Quick Start

Darca Plus Eltek Download ing And Remote Con trol Applica tion

Using Command Zone Software

Windows 8 / 7 CONTENTS. USB to RS-485 Converter. Part Number: USB FEATURES. 2 SPECIFICATIONS. 2 CONNECTIONS.. 3

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM.

Bluetooth to RS-232 Converter. RT-132B Bluetooth Adaptor Operation Manual

Addendum for 125B Bushealth Measurements

FT2 View Instruction Manual

PI Scanner User Guide

F-3100 FLOW METER NETWORK INTERFACE Installation and Operation Guide

EnerSure Installation Guide

UPDATING THE SYSTEM MANAGER SD Updating the System Manager with Prism 2

CO-485USB USB to RS-485 CONVERTER TECHNICAL REFERENCE

Fluke Metrology Software

3700 SERIES USER MANUAL

PCI Express 4-Port Industrial Serial I/O Cards

Product Specification for SAB-S-MODBUS

PRM Integration Guide with Pepperl+Fuchs HiDMUX2700 HART Multiplexer

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

Operating Bulletin. Model BB3-232 and BB3-I-232 USB Multi-Drop Box. The Fastest Flow Controller Company in the World!

ELK-IP232 INSTALLATION AND CONFIGURATION MANUAL. Ethernet to Serial Bridge /07

NGW-1. NMEA 2000 to NMEA 0183 Gateway. User Manual

Introduction & Specifications of Hi-Speed USB to Serial Adapters

Webinar Organizers. Ryan Shea. Bruce McDuffee. Joe Ryan. Webinar Moderator. Applications Specialist. Product Manager. Precision Digital Corporation

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

P3-SCM. General Specifications

Using PSpice to Simulate Transmission Lines K. A. Connor Summer 2000 Fields and Waves I

1 Introduction Required components Datalogger TrueLog Baseboard... 1

iologik R2140 User s Manual

Transcription:

Version 4..10 GosHawk II COMMUNICATIONS Operating Instructions Introduction This program is a set-up and diagnostic utility for the Hawk SULTAN range of ultrasonic units. Hawk SULTAN units are designed to communicate with a PLC or other control system, over a RS485 2-wire bus using the MODBUS protocol. A PC running the GosHawk ll program can also communicate with the SULTAN units over this bus, instead of the PLC. There are three ways a connection can be made between the PC and the RS485 bus. Direct connection to a PC com port via a RS22 to RS485 converter or via a PCMCIA RS485 adaptor. See page. A wireless connection via a GSM modem. See page 4. A TCPIP connection via the Internet. See page 6. Installing the program Place the GosHawk ll CD in the drive, access it from My Computer or Windows Explorer and double-click on Setup.exe. The program will be installed in C:\Program files\hawk\goshawk II. Setting up Up to 128 SULTAN units may be connected, in parallel, to the bus and each unit must be assigned a unique ID number (01-128) before communication is possible. A termination resistor of 120Ω should be connected across the bus at each end as per normal Modbus practice. See page 21. Hawk SULTAN units are shipped with the ID set to 01 which the user must change if more than one unit is to be used on a bus. It is recommended that the user avoid the use of the 01 ID on his system so that any new unit can be connected to the bus and its ID changed without affecting the already-connected units. Hawk Measurement Systems 15-17 Maurice Court Nunawading Vic 11 AUSTRALIA Phone: +61 987 4750 Fax: +61 987 458 info@hawk.com.au www.hawk.com.au

Running the program From the Desktop, click Start, Programs, Hawk, GosHawkk ll OR Navigate to C:\Program Files\Hawk\GosHawk and double-click on GosHawkll.exe. In future, it may be convenient to create a short-cut to this file. The program will come up displaying a box at the top of the screen as shown below. 1 2 4 5 6 1 2 4 5 6 Enable/Disable communications. See page 4 Select Device ID Read or Write Parameters. See page 8 Diagnostics display. See page 11 Tank view observe data from multiple units. See page 14 Overwrite (Flash) firmware. For loading updates or customized versions. See page 15. Page 2

Setting Communications Parameters Click View, click Options. The Properties screen comes up. If using a Direct connection to a PC com port via a RS22 to RS485 converter or via a PCMCIA RS485 adaptor 1 5 7 2 5 4 6 1 2 4 5 6 7 Set this field to the ID of the unit you wish to talk to. (02 in this example) Select Comms for Direct Connection Enter the number of the Port that your RS485 comms is on. This is the rate at which parameters are read (and/or written). Leave Speed at 19200 bps for SULTAN. This is the time that the program will wait to get a valid response from the SULTAN, for each query. 10mS is suitable for direct connection. Tick this box if the firmware in the SULTAN transducer is earlier than version 1.6. This can be confirmed from the Info Screen. See page 9 Connect the SULTAN ultrasonic unit to the PC via a RS22 to RS485 converter or PCMCIA RS485 adaptor. Three connections are required, A, B & GND. This can be done via a user s system bus provided that no other unit on the bus has the ID of 01. The user s PLC or control system must be disconnected. See Page 21. See page 20 for typical PCMCIA wiring. Page

Click the Connect button ( 1on page 2) to establish communication. The button icon changes to a hung-up telephone and is now used to disable communication Click the Setup button ( Go to page 6 on page 2) to bring up the Quick Start Menu screen. If using the wireless connection via GSM modem 1 2 4 6 5 6 7 8 1 2 4 5 6 7 8 Set this field to the ID of the unit you wish to talk to. Select Modem for GSM wireless connection. Enter the number of the Port that your computer s modem is on. This is the rate at which parameters are read (and/or written). Enter the phone number of the modem you want to call. Press TAB. Leave Speed at 19200 bps for SULTAN This is the time that the program will wait to get a valid response from the SULTAN, for each query. A longer time (Typically 1500mS) is required for modem transmission. Tick this box if the firmware in the SULTAN transducer is earlier than version 1.6. This can be confirmed from the Info Screen. See page 9 Page 4

Block diagram of a GSM connection PC running GosHawk II RS22 Modem PSTN (Any distance) GSM Network RS485 Bus Other units on bus Sultan with GSM Module fitted G S M Click the Connect button ( 1 on page 2) The button icon changes to a hung-up telephone and is now used to disable communication. The Dial Number box comes up as shown below. Click OK The Status box indicates call progress. When the connection is established, click the Setup button ( on page 2) to bring up the Quick Start Menu screen. Go to page 6 Page 5

If using a TCP-IP connection via the Internet This option is not available yet. Changing the Device ID of a SULTAN unit When communication has been established with a SULTAN, its Device ID can be changed if required. To do this, follow these steps 1 Bring up the properties screen by clicking on View and then Options. Double-click here to bring up the Device ID Information screen for the new ID. ( 02 in this case) 2 Click the down arrow of the ID box, select the desired new ID from the list, if it is not in the list it can be added at the bottom Page 6

Double-click on the ID bar as shown above, the Device ID Information screen comes up. 1 2 4 Click Write ID 1 a box comes up asking for the current ID number. 5 Enter the current ID number. (01 in this example) Click OK 2 6 Click Close Page 7

Reading & Writing Parameters Clicking the Read/Write Parameters (Setup) button ( up the Quick Start Menu screen as shown below. on page 2) brings 1 Parameters that were read successfully and were legitimate will be displayed on a green background. A red panel will be displayed if a parameter cannot be accessed or is outside normal limits. Changing parameters Click on any parameter field to alter it. The field will turn gray. The data may now be altered. Leaving the field by enter or tab will cause the data to be written to the device and read back. If the new value was successfully written and read back that field will turn green. A value outside normal limits will not be accepted and the field will turn red. To initiate a new read of all parameters (refresh), click the Read All Parameters button 1 Clicking the Down Arrow of the Setup button gives the option of displaying Info Quick Start Tx Setup Tracking Factory Page 8

The Info screen Transducer Setup Menu Page 9

Tracking Menu Factory Menu Page 10

Diagnostics Clicking on the Diagnostic button ( similar to this below. 4 on page 2) brings up a screen 1 1 2 4 7 5 8 9 6 10 11 12 1 The top section 1 is a graph of the loop current output over time. Positioning the cursor anywhere on the trace will display the current value at that point, in the top right corner 2 while the mouse button is held down. The bottom section is a display of the echos received, their amplitude and their distance. The step in the horizontal white line 4 represents the time window in which the unit is looking for a valid echo. The horizontal yellow line 5 represents the threshold. (0.4v in this case) The horizontal distance scale can be expanded or contracted with the Scale adjustment. 6 The total length can be 1m, 10m, 20m, 40m, or 60m Clicking anywhere, the tip of an echo for example, will display the voltage at that point, in the top right corner. 7 Page 11

The following data are displayed on the right side of the screen: 8 Dist: E-Dist: Size: Gain%: Recov: Noise%: Temp: Confirm: Hold: WinUp: WinDw: The distance (in metres) from the transducer face to the product being measured. This corresponds to the green displayed echo. Estimated Distance. Used during start-up to get an approximate distance before the advanced processing produces the final value. The minimum amplitude for an echo to be accepted when in the recover mode. The percentage of gain that is being used for this measurement. The gain percentage increase applied to recover from a loss of signal. The noise level expressed as a percentage of gain. The current temperature (in degrees Centigrade) measured at the transducer The number of consecutive, consistent echos received before being confirmed as valid. The number of transmit-and-measure cycles performed, when no echo is detected, before the unit goes into Recover mode. The distance per pulse that the window will move forwards to go to another echo when the unit is in the recover mode The distance per pulse that the window will move backwards to go to another echo when the unit is in the recover mode. Note In the Recover mode the window will double in width after the Hold No counts down to zero. If no echo is confirmed in this larger window the recover mode will continue until the window covers the position of the echo. The output will then move to the new echo position at a rate dictated by the damping number. Page 12

Echos that are mapped out are displayed in red. This information is only read from the SULTAN once, so if a change is made to the mapping the display will not be updated until the refresh button 9 is clicked. The three windows along the bottom 10 11 12 configured to display a number of variables can each be Window 10 Threshold Blanking can be Window 11 can be Recover Recover Increment Dist Step Window Window 12 can be Slope Gain Step 1 Dist Step 1 Gain Step 2 See the Hawk SULTAN Manual for explanation of these terms Click the Log button 1 to activate the data-logging function, a box comes up in which you specify the location and filename for the data file. A text file will be created and each line contains the following data Date,Time,Device ID,Distance,E_Dist,Size,Gain,Recover, Noise,Temp, Confirm,Hold,Win Start,Win End, EchoNo1,Start Dist1,Peak Dist1,Size1,Gain1,EndDist1, EchoNo2,Start Dist2,Peak Dist2,Size2,Gain2,EndDist2, EchoNo,Start Dist,Peak Dist,Size,Gain,EndDist, EchoNo4,Start Dist4,Peak Dist4,Size4,Gain4,EndDist4, EchoNo5,Start Dist5,Peak Dist5,Size5,Gain5,EndDist5, EchoNo6,Start Dist6,Peak Dist6,Size6,Gain6,EndDist6, EchoNo7,Start Dist7,Peak Dist7,Size7,Gain7,EndDist7, EchoNo8,Start Dist8,Peak Dist8,Size8,Gain8,EndDist8, EchoNo9,Start Dist9,Peak Dist9,Size9,Gain9,EndDist9, EchoNo10,Start Dist10,Peak Dist10,Size10,Gain10,EndDist10 Page 1

Tank view Clicking the Tank View button ( 5 on page 2) allows the data from multiple units to be displayed, nine units per screen, as shown below. In this example, Device ID records have been created for seven units (01-07) but only one unit (device ID = 02) is connected. If more than nine device ID records exist, buttons for the next and subsequent screens will be displayed here Page 14

Updating Firmware The SULTAN firmware can be overwritten (flashed) to load updated or special customized versions. The amplifier and transducer programs are loaded separately and independently. Requirements Software to load this will be supplied as a.pga file for the amplifier and/or a.pgt file for the transducer. Adaptor board and cable only required for programming the transducer of an integral unit. Procedure Load the program file(s) into a suitable folder in the computer such as c:\program files\hawk\goshawk\software. It is wise to move any old or obsolete.pga and.pgt files that may have been left from a previous programming session, into a separate folder, such as...\software\old Programming the Transmitter (Amplifier) Click the down arrow of the Flash button. ( 6 on page 2) Select Transmitter (amplifier) A box comes up asking Do you want to flash the transmitter? Click Yes A Look in box requests the location of the file to be loaded. Navigate to the folder where you stored the program file(s). c:\program files\hawk\goshawk\software for this example. Select the appropriate.pga file. Click Open. The Status bar says Flashing Device 001 and indicates progress. When finished a box comes up saying Flashing was successful Click OK Page 15

Programming the Transducer Remote Transducer Leave the transducer power wires (Red & Black) connected to the amplifier unit but disconnect the signal wires (White & Blue) and connect them, instead, to the RS485 line from the computer. White = A, Blue = B. Also connect ground between Sultan and computer. Integral Transducer Unplug the cable from the transducer to the terminal board (5-pin connector) and plug it into the TO TX socket on the adaptor board. Connect the TO AMP socket on the adaptor board to the (now vacant) transducer socket on the terminal board (HAW-AWI TM) using a 5-way cable. TERMINAL BOARD HAW-AWI TM TO AMP Adaptor board HAWK TXAMP A B COMPUTER RS485 TO TX GND TRANSDUCER Connect the A, B, GND terminals on the adaptor board to the RS485 line from the computer. Click the down arrow of the Flash button ( 6 on page 2). Select Transducer A box comes up asking Do you want to flash the transducer? Click Yes Page 16

A Look in box requests the location of the file to be loaded. Navigate to the folder where you stored the program file(s). c:\program files\hawk\goshawk\software for this example. Select the appropriate.pgt file. Click Open. The Status bar says Flashing Device 001 and indicates progress. When finished a box comes up saying Flashing was successful Click OK Disconnect power from the Sultan. Disconnect the adaptor board (if used) and re-connect the transducer. Page 17

Troubleshooting Unable to communicate with a HAWK device? Check the communication parameters, correct Com port selected? Note that it is possible for windows to re-assign a logical com port number to a different hardware port. Port operation can be confirmed by connecting a CRO between Ground (Pin 5) and Data Out (Pin ). (for a 9-pin connector) Set the sensitivity to 5V/div and the timebase to 2mS/div. If the port is working, the output will be at approx 12v with data pules going to +12V when the Connect to Parameters button is clicked, as shown below. 0V RS22 DATA OUTPUT FROM PC Page 18

Check that the RS22 to RS485 converter is working by observing the RS485 output when data is sent by the PC. Data on the bus should be between 10V and 2V p-p, measured between the bus wires. Use a CRO with isolated ground such as the Fluke 12 Scopemeter. Interrogation from controller Response from SULTAN SCREEN FROM SCOPEMETER CONNECTED ACROSS THE BUS Ensure that the correct model (SULTAN or GLAD) has been entered in the DEVICE ID INFORMATION screen. See page 7. Check that the Device ID selected in the program matches that of the actual device. Page 19

RS485 Biasing 2200Ω +24v 680Ω 5.6v +24v A RS22 RS-22 To 150Ω RS485 bus RS-485 Converter B 120Ω GND 680Ω GND The above network can be used if noise is causing problems with RS485 transmission. It biases the bus into the idle state when no device is transmitting, that is A is held about 500mV more positive than B when all drivers are in the high-impedance state. This whole network replaces the 120Ω termination resistor at the converter end of the bus. D9 Male 5 o o 9 o o o o o o 6 1 o A B GND Connections for the Quatech RS485 PCMCIA card Page 20

MODBUS Communication with multiple Sultan units A 120 ohm termination resistor must be connected across the bus at both ends. Avoid stubs if possible. Maximum number of units on bus is 128. 1 2 0 120Ω PC Running the GOSHAWK II program RS22 RS22 485 + TO 485 - RS485 +V CONVERTER GND POWER SUPPLY 24V + Allow for 100mA - average per unit HAWK SULTAN ID = 02 HAWK SULTAN ID = 0 - - - - HAWK SULTAN ID = n Page 21