Operating Instructions. For. Level Control Module. Model SSR 1000

Similar documents
MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

Operating Instructions. Power Supply & Latching Relay For Switches Model: RL manual_rl-6000_1016

Operating Instructions. Power Supply & Isolation Relay for Switches Model: RL manual_rl-5900_0215

Operating Instructions. Isolation Relay for Switches Model: RL manual_rl-6100_1116

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.

Safety Control Relay Product Catalog

Phase loss monitor CM-PBE Phasemonitor for over and undervoltage CM-PVE Ordering details

Remote Relay Controller LC40, LC41 and LC42 Series Owner s Manual

LC-5 Level Controller & Flow Monitor

LC-1 Level Controller & Flow Monitor

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA SST7000 SST7100. Speed Switch / Transmitter

Tempco Instruction Manual

SS2200 Remote Controller

SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

Manual Control Unit GFC 32

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

700 SERIES DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

PHASE MONITOR RELAYS Product Summary

LCI Load Cell Junction Box with Fault Monitor

Pump-Down Controller MODEL mA Input Scalable 4-20mA Output Duplex Pump Alternation Hand-Off-Auto Controls Dual Run-time Meters

ALTERNATING RELAYS & CONTROLLERS ARM Series

SMART SHOT CONTROLLER FLUID USERS GUIDE

Operating Instructions for Digital Thermometers. Model: DTM

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

LCI User Manual mantracourt.com

Compact Coded Magnetic Safety Interlock Switch and Control Units

External level devices for conductive point level switch

700 SERIES FLOAT OPERATED DUPLEX/TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

INTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL

Manual Simatek Control Unit GFC 32

Masibus Automation And Instrumentation Pvt. Ltd.

700 SERIES TPC TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

SNAP Digital Output Modules. SNAP Digital Output Modules. Features. Description

SafeC S to MSR127 Conversion

Intrinsically Safe Barriers

Digital Frequency Divider INSTRUCTION MANUAL CONTENTS. 1. Working Principle Installation Setting Up Technical Data 4.

Operating Instruction for Turbine-wheel Flow Meter. Model: DRS

EOTec MX Multiplexer System

Operating Instructions for Vibrating Level Switches. Model: NVI

Operating Instruction for Rotating Vane Flow Meter. Model: DRG-...

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

PC-200-LLC-GM INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 10/2009 II_PC-XXX-LLC-GM_A1

MAXIMA + Series ROTARY LEVEL CONTROL

INSTRUCTIONS FOR MODEL 1000 DIGITAL PROCESS INDICATOR AND ALARM

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

PGR-3200 MANUAL INSULATION MONITOR

Operating Instructions for Differential Pressure Sensor. Model: PMP

CM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

SE-135 MANUAL GROUND-FAULT GROUND-CHECK MONITOR

78 Series Electromechanical Relay Selection Guide

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

Operating Instructions for Level Switch for Liquids. Model: RFS

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

Electronic Temperature Controller. Instruction Manual Version

INSTALLATION INSTRUCTIONS. Revision C1 Rapid City, SD, USA, 02/2010 MODEL ALT-XXX-3-SW

PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR

Ground Fault Protection

E1 Plus Electronic Overload Relay

MYRIAD LC1 LEVEL CONTROLLER INSTRUCTION MANUAL

AP-7 Pump Station Controllers

OPERATOR S MANUAL 9000U ISOLATOR

Series 8000 RF Signal Switch Solution

User Manual. Item no.: Otto Graf GmbH Carl-Zeiss-Str. 2-6 Tel.: +49(0) Kunststofferzeugnisse D Teningen Fax: +49(0)

531K. Process Display Temperature display for Pt100 and Ni100 RTD's. Installation and Operating Manual

PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

NSGV Series "90DM3" Carbon Dioxide Detector

KILOVAC WD Series, DIN Rail or Screw Mounted Protective Relays

PRODUCT SPECIFICATION. PC Board Relays. Series.

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

Safety Relay Unit (I/O Unit Type)

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0)

Users Manual. TABLE OF CONTENTS 1 WORKING PRINCIPLE Operating limits Applications... 2

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

MAXIMA+ Series Rotary Level Indicator

Switching module for AC V and up to three load stages, with manual switching

VM-11 SERIES MODEL VM-11B ACCELERATION INPUT VIBRATION SIGNAL CONDITIONER INSTRUCTION MANUAL. MANUAL No E1.8. Revised in Mar.

Magnetic Style Safety Interlock Switches

Safety Monitoring Relays

MSR178DP. Description. Features. Specifications

HERZ Actuator 7708, 7990

AirTest Model CN9000 Series Sensor Controller

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

Model 7705 Control Module

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

Switching modules for AC 230 V, non-potential-free, single and double module

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

Transcription:

Operating Instructions For Level Control Module Model SSR 1000 SSR Operation Instructions Rev. 1 Jan 01 Page 1/7

1. Note Please read and take note of these operating instructions before unpacking and commissioning. The instruments may only be used, maintained and installed by qualified personal familiar with the operating instructions and the applicable health and safety requirements. 2. Contents 1. Note 2. Contents 3. Specific Applications 4. Operating Principle 5. Instrument Inspection 6. Mechanical Installation 7. Technical Specifications 8. Electrical Connections 9. Start Up 10. Troubleshooting 11. Maintenance 3. Specific Applications The Level Control Module has been designed for use in level monitoring applications and pump control for liquids The module consists of a transformer, control logic circuit and output relay The SSR is a bi stable latching type control module with SPDT relay contacts output. Inputs should be dry (potential free) contacts, for example reed switch contacts from a float type level detector. The module generates 24VDC to detect input switch closure; the current is limited to 20 ma on the inputs, in order to protect the level switches. In addition the module has built in time delay on the inputs, which avoids false triggering due to switch bounce or nuisance tripping from process vibration, waves or bubbles. 4. Operating Principles The module is designed to provide detection of two levels in a process tank and control the tank level in either a pump-up or pump-down mode of operation. Pump-Up Mode In a pump up mode, the relay will initiate by switching the pump when the fluid level in the tank falls below the lower tank level switch. The relay will remain energized (latched) and the pump will continue to operate until fluid fills the tank up to the high level switch. When the fluid reac hes the high level switch the control relay will de-energize and shut off the pump. The control module relay will remain de-energized until the fluid falls below the low tank level switch. Pump-Down Mode In a pump-down mode, the relay will imitate by switching on the pump when the fluid level in the tank reaches the upper tank level switch. The relay will remain energized (latched) and the pump will continue to operate until fluid inn the tank empties down to the low level switch. When the fluid falls below the low level switch the control module relay will de-energize and shut off the pump. The control module relay will remain de-energized until the fluid reaches the high level switch.

SSR Operation Instructions Rev. 1 Jan 01 Page 2/7 5. Instrument Instructions The instruments are thoroughly inspected by the factory prior to shipment and sent in perfect condition. Should any damage to the device be visible, we recommend a thorough inspection of the delivery packing. In case of damage please inform your parcel service/forwarding agent immediately, since they are responsible for damages incurred during transit. Scope of delivery: Level Control Relay Module Operation Manual 6. Mechanical Installation The relay module enclosure is rated IP 20 (approx. equivalent to NEMA 1), which is intended for use in dry, dust free environment. If the relay module will be located in harsh, wet or dusty environments, the user should mount in an appropriate enclosure to protect the device. For example - NEMA 4X electrical enclosure. The relay module can be mounted on to a standard DIN mounting rail, according to DIN 46277, EN50022. The device snaps on to the DIN rail and can be removed from the rail by releasing the spring-loaded clip, located on the bottom of the device. Drawing Pending

Operation Instructions Rev. 1 Jan 01 Page 3/7 7. Technical Specifications Preliminary Technical Data Sheet Instrument Type Electromechanical Contact Protection Relay Model SSR 1000 Housing Size 75mm x 50mm x 100mm Housing Material Polyamide 6.6 Supply Voltage 115 VAC +/- 10% 50 60 Hz Power Consumption 5 VA (typical) Control Voltage 24 VDC Control Current 20 Ma Input Impedance 3300 Ohm, 100 nf +/- 20% Maximum Contact ON Impedance 4700 Ohm, 47 nf at inputs Delay Period (initiating) 10 ms Delay Period (dropping) 20ms Output 1 SPDT relay contact Permissible Load 250 VAC / 8A resistive / 1840 VA Temperature range -20 deg. C to 60 deg. C Type of protection IP 20

Operation Instructions Rev. 1 Jan 01 Page 4/7 8. Electrical Connection ATTENTION: Ensure that the voltage levels of your supply system are in agreement with the voltage levels given on the Type Label of the device. Make sure that the electric supply lines are not active during connection to this device. Improper wiring can lead to damage of this device as well as injury to the user. Make sure that installation; wiring and circuit protection are in accordance with all local electrical codes. Make sure the supply circuit provides adequate fuse or circuit breaker protection that is in accordance with the circuits current rating. Make sure that a motor contactor relay or starter is used to energize the pump circuit, if the pump current rating exceed the SSR 1000 Level Control s relay rating. Electrical connections to the relay module are made by - connecting the wires to the numbered screw terminals. Wiring is per attached drawings and specifications. Wiring Table Terminal # Description Function A1 Mains Connection Connect to 115 VAC Supply A2 Mains Connection Connect to Mains Neutral Supply 12 Sensor Input Common Connect to one side of switches 13 START Input Momentary Closure of 12 and 13 Energizes Output Relay (latched) 11 STOP Input Momentary Closure of 12 and 11 DE Energizes Output Relay (Reset) 42 Relay Output Common Common Wire 41 Relay Output N/C Normally Closed Contact When Relay Energized 42 and 41 Open 43 Relay Output N/O Normally Open Contact - When Relay Energized 42 and 43 Close 82 & 81 24 VDC Excitation Sensor Supply Maximum 20 ma A1 42 12 13 11 L N 12 DC 13 11 ( - ) ( + ) 41 43 82 81 A2

Operation Instructions Rev. 1 Jan 01 Page 5/7 Start & Stop Hi and Low-level Contacts Located on Tank Start Stop A1 42 12 13 11 L N 12 DC 13 11 ( - ) ( + ) 41 43 82 81 A2 115 VAC 50-60 Hz Mains Supply LOAD NOTE: When using multi level or side mount switches Pump-Up Application: Start = Bottom Position N/C Dry Stop = Top Position N/O Dry Pump-Down Application: Start = Top Position N/O Stop = Bottom Position N/C Dry Recommend including backup safety switches Example Hi Alarm for overflow protection In the event of pump or circuit failure Operation Instructions Rev. 1 Jan 01 Page 6/7

Wiring Diagram for Pump Control 9. Start-Up Ensure that all wiring to the Level Control Module is correctly installed and the level switches are installed and functioning correctly. The Relay Module is now ready for operation and the supply power to the level control circuit can be applied. Depending on whether the module is wired for pump-up or pump-down mode of operation, the relay should operate in accordance with the description in section 4. Operating Principals. 10. Troubleshooting The relay does not operate: Check the mains voltage is applied to the L and N terminals on the module. Check that there is 24 VDC across terminals 82 and 81. If mains voltage is applied and no 24 Volts is measured across 82 and 81 the module may be defective. Check level switch operation and cabling from the tank location to the module. Temporarily remove the switch inputs from the module and simulate level switch closure using jumper wires across input terminals. (this is a latching relay - so test as such) When simulating level switch closures, the relay does not activate, the relay may be faulty. If the relay activates but does not start the pump, the output wiring circuit may be faulty. 11. Maintenance The Level Relay Module requires absolutely no maintenance. Depending on the type of level sensors used and the process conditions, maintenance to the sensors may be required. Verify and follow maintenance procedures according to the sensor maintenance manual. Verify and follow maintenance procedures according to the pump or solenoid manufacturer s maintenance manual. There are no user serviceable parts inside the SSR 1000 module. If repair is required please contact your local distributor to ret urn for repair. Your Distributor Is Operation Instructions Rev. 1 Jan 01 Page 7/7