PLIN-LWL Optical Coupler for LIN Data Transmission. User Manual. Document version ( )

Similar documents
PCAN-Repeater DR CAN Repeater for the Decoupling of Bus Segments. User Manual. Document version ( )

PCAN-Repeater 2-Channel CAN Repeater with galvanic isolation. User Manual V1.0.0

PCAN-B10011S Bus Converter High-speed CAN to Truck-Trailer CAN. User Manual V2.0.0

PCAN-TJA1054 Bus Converter High-Speed CAN to Low-Speed CAN. User Manual. Document version ( )

PCAN-Optoadapter Plug-on Adapter for Decoupling CAN Networks. User Manual. Document version ( )

MU-Thermocouple1 CAN. Temperature Measurement Unit with CAN Connection. User Manual

PCAN-Repeater DR CAN Repeater for the Decoupling of Bus Segments. User Manual V1.1.0

PCAN-Router FD Universal, programmable Converter for CAN FD and CAN. User Manual. Document version ( )

PCAN-MicroMod Analog 2 Application-specific PCAN-MicroMod Motherboard. User Manual. Document version ( )

PCAN-MicroMod Analog 1 Application-specific PCAN-MicroMod Motherboard. User Manual. Document version ( )

PCAN-PCI Express CAN Interface for PCI Express. User Manual. Document version ( )

PCAN-MicroMod Digital 1 & 2 Application-specific PCAN-MicroMod Motherboard. User Manual V1.10.0

PCAN-cPCI CAN Interface for CompactPCI. User Manual. Document version ( )

PCAN-PC/104-Plus Quad Four-Channel CAN Interface for PC/104-Plus. User Manual. Document version ( )

PCAN-MicroMod Mix 2 Application-specific PCAN-MicroMod Motherboard. User Manual. Document version ( )

PCAN-LIN Interface for LIN, CAN, and RS-232. User Manual. Document version ( )

PCAN-PCI/104-Express CAN Interface for PCI/104-Express. User Manual. Document version ( )

PCAN-PCI Express FD CAN FD Interface for PCI Express. User Manual. Document version ( )

PCAN-B10011S. Converter High-speed CAN to Truck Trailer CAN. User Manual

PLIN-Slave Test-Slave for the LIN Bus with Various I/Os. User Manual V1.1.0

PCAN-ExpressCard 34 CAN Interface for the ExpressCard/34 Slot. User Manual. Document version ( )

PCAN-USB CAN Interface for USB. User Manual. Document version ( )

PCAN-ExpressCard CAN Interface for the ExpressCard Slot. User Manual. Document version ( )

PCAN-MicroMod Mix 3 Application-specific PCAN-MicroMod Motherboard. User Manual V2.1.0

PCAN-MicroMod Mix 2 Application-specific PCAN-MicroMod Motherboard. User Manual. Document version ( )

PCAN-PCI Express. PCI Express to CAN Interface. User Manual

PCAN-USB FD CAN FD Interface for High-Speed USB 2.0. User Manual. Document version ( )

PCAN-MiniDiag FD PCAN-MiniDiag Diagnostic Device for CAN FD FD Buses. User Manual. Document version ( )

PCAN-cPCI CompactPCI to CAN Interface. User Manual V2.0.0

PCAN-USB X6 CAN FD Interface for High-Speed USB 2.0. User Manual. Document version ( )

PCAN-PC/104-Plus Quad Four-Channel CAN Interface for PC/104-Plus. User Manual V1.0.1

PCAN-PCI Express PCI Express to CAN Interface. User Manual V3.2.0

PCAN-PCI. PCI to CAN Interface. User Manual

PCAN-miniPCIe FD CAN FD Interface for PCI Express Mini. User Manual. Document version ( )

PCAN-PCI Express PCI Express to CAN Interface. User Manual V2.0.0

PCAN-USB CAN Interface for USB. User Manual. Document version ( )

PCAN-PCI PCI to CAN Interface. User Manual V2.1.0

PCAN-PC Card PC Card to CAN Interface. User Manual V2.1.1

PCAN-ExpressCard ExpressCard to CAN Interface. User Manual V2.0.0

PCAN-PCI/104-Express PCI/104-Express to CAN Interface. User Manual V2.1.0

Mix 2. Motherboard for the PCAN-MicroMod. User Manual

PCAN-USB Pro FD CAN FD and LIN Interface for High-Speed USB 2.0. User Manual. Document version ( )

PCAN-M.2 CAN FD Interface for M.2 (PCIe) User Manual. Document version ( )

PCAN-PCI (ISO) Adapter Card PC-PCI to High-speed CAN. User Manual

PCAN-USB Pro CAN/LIN Interface for High-Speed USB 2.0. User Manual. Document version ( )

PCAN-Dongle. User Manual. Parallel Port to CAN Interface. Document version ( )

PCAN-Dongle. Parallel Port to CAN Interface. User Manual

Mix 2. Motherboard for the PCAN-MicroMod. User Manual

PCAN-PC/104 CAN Interface for PC/104. User Manual V2.2.3

PCAN-Flash Windows-Software for Flashing Firmware via CAN. Operation Instructions. Document version ( )

PCAN-Router Universal CAN Converter. User Manual V1.2.0

PCAN-Router. Universal CAN Converter. User Manual

Wireshark Dissector for PCAN-Gateways IPEH , IPEH ,IPEH (A) User Manual. Document version 1.0 ( )

HARDWARE MANUAL ENGLISH

LANGER EMV-TECHNIK. Operating instructions. CAN 100 Optical fibre probe. 1. Use 2

CAN Repeater CAN-CR200, CAN-CR220, CAN-CR210/FO

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

IBS IL 24 RB-LK-2MBD:

The sensor fulfills the specifications of the EMC requirements, if the instructions in the manual are followed.

Operating and mounting instructions

FLEX Ex Spring Clamp Terminal Base

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

ABB i-bus KNX IP Router, MDRC IPR/S 3.1.1, 2CDG110175R0011

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

FL SWITCH SFN 5TX. Extract from the online catalog. Order No.:

Channel Switch CS. General Operating, Maintenance and Installation Manual

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

PHOENIX CONTACT - 12/2007

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

PI-EX-ME-2NAM/COC-24VDC

Field bus connections Link structure BDC Link structure BDC, B-design. Brochure

DF PROFI II PCIe. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II PCIe KUNBUS

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

Manual Fiber Optic Interfaces

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Fiber optic converter audio and CAN TA OPERATION MANUAL

Assembly Instructions scancontrol 2700/2750 (500)

PHOENIX CONTACT - 10/2009

MINI MCR-SL-UI-2I(-SP)(-NC)

PSI-MOS-PROFIB/FO 850 T

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

BTL6-V1 _ E-M -A1-S115 User's Guide

AS-Interface I/O Module

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Operating instructions valve control box AS-i

MINI MCR-SL-PT100-UI(-SP)(-NC)

camera sensor ipf opti-check 1070 fully integrated camera system contour-based recognition

Serial PROFIBUS Interface

PI-EX-ME-2NAM/COC-120VAC

TXM1.8RB. TX-I/O Blinds module

PSI-MOS-PROFIB/FO 850 T

Manual Industry Interfaces

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

Flow Sensor SONOFLOW CO.55

PHOENIX CONTACT - 05/2007

Brief instruction. Version. 3en.

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Transcription:

PLIN-LWL Optical Coupler for LIN Data Transmission User Manual Document version 1.1.1 (2017-01-27)

Relevant products Product Name Model Part number PLIN-LWL IPEH-004049 All product names mentioned in this document may be the trade marks or registered trademarks of their respective companies. They are not explicitly marked by and. Copyright 2017 PEAK-System Technik GmbH Duplication (copying, printing, or other forms) and the electronic distribution of this document is only allowed with explicit permission of PEAK-System Technik GmbH. PEAK-System Technik GmbH reserves the right to change technical data without prior announcement. The general business conditions and the regulations of the license agreement apply. All rights are reserved. PEAK-System Technik GmbH Otto-Roehm-Straße 69 64293 Darmstadt Germany Phone: +49 (0)6151 8173-20 Fax: +49 (0)6151 8173-29 www.peak-system.com info@peak-system.com Document version 1.1.1 (2017-01-27) 2

Contents 1 Introduction 4 1.1 Properties at a Glance 4 1.2 Operation Requirements 5 1.3 Scope of Supply 5 2 Connectors 6 2.1 LIN 6 2.2 Optical Waveguides (OWG) 7 2.3 Voltage Supply 8 3 Configuration 9 3.1 Configuration LIN Transceiver 10 3.2 Configuration Power Supply 11 3.3 Configuration Internal Supply 13 3.4 LIN Master Termination 14 4 Operation 15 4.1 LIN Transmission Rate 15 4.2 Status LEDs 15 5 Technical Specifications 16 Appendix A CE Certificate 17 Appendix B Emission Diagram 18 Appendix C Dimension Drawing 19 3

1 Introduction For use in explosion-proof areas or for EMC measurements, the PLIN-LWL can be used to replace a stretch of LIN network with a fiber-optic line at any point. The modules are supplied with power externally. 1.1 Properties at a Glance Bit rates from 2.4 kbit/s 1 up to 20 kbit/s 2 types of the TJA1028T LIN transceiver built in, use depending on the bit rates and EMC requirements LED display for power supply and transceiver status Switchable master termination LIN bus connection via D-Sub, 9-pin Fiber-optic duplex line, 62.5/125 μm, ST connectors Supply voltage 8 to 30 V DC Supply via D-Sub 9-pin or DC connector (jumper) Aluminum casing Extended operating temperature range from -40 to 85 C (-40 to 185 F) 1 2.7 kbit/s if 16 (instead of 13) bits are used for the break pulse 4

1.2 Operation Requirements LIN network (Master or Slave termination can be selected per module) D-Sub sockets for connection to the PLIN-LWL modules Power supply with power supply unit or via the D-Sub connector 1.3 Scope of Supply 2 PLIN-LWL modules including power supply units A choice of 5 or 10 m FO cable, 62.5/125 μm duplex line ST connector, other lengths available on request Manual in PDF format 5

2 Connectors 2.1 LIN Figure 1: Casing side with toggle switch and D-Sub connector for LIN The LIN bus is connected to the 9-pin D-Sub connector on the left casing side. Figure 2: Pin assignment D-Sub connector Pin 9 can be used to supply a PLIN-LWL module. See section 3.2 Configuration Power Supply on page 11 for further information. 6

2.2 Optical Waveguides (OWG) Figure 3: Casing side with OWG connectors, voltage socket, and LEDs A PLIN-LWL module has two standardized ST connectors for the optical waveguides. The connections are separately in charge of sending and receiving light signals. Both optical waveguides of the duplex line are marked with colors at each connector (red/black). For both modules, connect the OWG output of one module with the OWG input of the other. Optical wave guide (marker) Connector at 1 st PLIN-LWL module Connector at 2 nd PLIN-LWL module Red OWG IN (gray) OWG OUT (light gray) Black OWG OUT (light gray) OWG IN (gray) 7

2.3 Voltage Supply A PLIN-LWL module needs a DC voltage of 8 to 30 V. At the voltage input socket you can connect the supplied 12-Volt power supply unit. Figure 4: Assignment voltage input socket Figure 5: Diameter barrel connector: a = 5.5 mm, b = 2.1 mm See section 3.2 Configuration Power Supply on page 11 for further information. 8

3 Configuration At the PLIN-LWL housing, a termination for the Master operation mode can be switched on with a toggle switch. On the circuit board of the module, you can do the following jumper settings affecting the basic operation: Choice between High-speed and Low-speed LIN transceiver Configuration of the power supply Configuration of the internal supply Tip: At delivery, the PLIN-LWL modules use the High-speed transceiver for the data transmission. The power supply for the module and the LIN bus is configured to be done with the power supply units via the DC socket. If you use this common configuration, a change of the settings as described in this chapter is not needed. For doing jumper settings, the circuit board must be taken out of the casing. To do so, do the following: 1. If extant, remove the protecting caps from the OWG connectors (right housing side). 2. Remove the two screws on the left housing side (the one with the D-Sub connector). 3. Pull the circuit board with the lid out of the case. After changing the settings (see the following subsections), the assembly is done in the reversed order. 9

3.1 Configuration LIN Transceiver According the highest bit rate that is used on the LIN bus, you can select between two LIN transceivers: max. 10,4 kbit/s: TJA1028T/5V0/10 (Low-speed) max. 20 kbit/s: TJA1028T/5V0/20 (High-speed, default setting) The transceiver with the /10 ending generates less steep slopes, thus the electromagnetic compatibility is enhanced. Figure 6: Position of the jumper blocks JP3 and JP7 Transceiver Jumper setting Comment JP3 and JP7 Low-speed (/10) 1-2 High-speed (/20) 2-3 Default setting at delivery Tipp: Both PLIN-LWL modules being connected with each other can use different LIN transceiver settings. 10

3.2 Configuration Power Supply A PLIN-LWL module can be supplied either by an external voltage source (e.g. the supplied power supply unit) via the corresponding input socket or via pin 9 of the D-Sub connector (in each case 8-30 V DC). The input for the power supply is set with various jumper blocks. It is possible to determine the supply of LIN and the module separately. Figure 7: Position of the jumpers JP4, JP5, and JP6 LIN voltage supply via Jumper JP5 Comment D-Sub connector, pin 9 1-2 Supply socket 2-3 Default setting at delivery Module voltage supply via D-Sub connector, pin 9 Supply socket Jumper JP4 and JP6 JP4 closed JP6 open JP4 open JP6 closed Comment Default setting at delivery 11

When having increased EMC requirements, it is recommended to use a shielded cable for the supply and for LIN. In addition, the power supply via the DC socket should be preferred. The unused power supply input (according to the setting) is electrically isolated from the actual power supply. Attention! Switch off the power supply at the D-Sub connector before connecting or removing the D-Sub plug to or from the PLIN-LWL module. Otherwise electronic parts may be destroyed, even on other nodes attached to the LIN bus. 12

3.3 Configuration Internal Supply The PLIN-LWL has a linear and a switching regulator for generating the internal 5-volt supply. The jumpers JP8 and JP9 determine which voltage transformer is used. Switching regulators can cause unwanted oscillations. Linear regulators are no problem regarding electromagnetic interference (EMI), but lead to warming in the upper voltage supply range instead. At delivery the PLIN-LWL is configured to switch automatically from the linear to the switching regulator at 20 V. Figure 8: Position of the jumper blocks JP8 and JP9 Jumper JP8 open JP9 closed JP8 open JP9 open JP8 closed JP9 open Used voltage transformer For voltages lower 20 V the linear regulator is used. At 20 V the module switches automatically to the switching regulator. Default setting at delivery Only the switching regulator is used. Only the linear regulator is used. 13

3.4 LIN Master Termination The PLIN-LWL can be operated in a LIN bus as Master or Slave. If using as Master, the toggle switch at the left side must be set to the lower position. This enables a termination of 1 k which enhances the level and the flanks of the transmitted signal. Figure 9: Toggle switch at the casing side with D-Sub connector 14

4 Operation 4.1 LIN Transmission Rate When operating the PLIN-LWL modules, it must be ensured that the transmission rate of all participants connected to the LIN bus is identical. There is no conversion or automatic adaptation of the bit rate. 4.2 Status LEDs Figure 10: Casing side with OWG connectors, voltage socket, and LEDs LED Yellow Orange Green Meaning Transmitting data onto the LIN bus (the orange LED is lit simultaneously) Receiving data from the LIN bus Ready for operation, voltage is applied 15

5 Technical Specifications LIN High-speed LIN Low-speed LIN Optical waveguide D-Sub male connector, 9-pin Transceiver: TJA1028T/5V0/20 Bit rates: 2.4 2-20 kbit/s D-Sub male connector, 9-pin Transceiver: TJA1028T/5V0/10 Bit rates: 2.4 2 10.4 kbit/s Fiber optic duplex line with ST connector Power supply Supply voltage Current consumption per module 8-30 V DC max. 50 ma (at 12 V) Environment Operating temperature Temperature for storage and transport Relative humidity EMC Ingress protection (IEC 60529) -40 - +85 C (-40 - +185 F) -40 - +100 C (-40 - +212 F) 15-90 %, not condensing Directive 2014/30/EU DIN EN 55024:2016-05 DIN EN 55022:2011-12 IP20 Measures Size 60 x 35 x 80 mm (W x H x D) See also dimension drawing Appendix C on page 19 Weight per module 150 g 2 2.7 kbit/s if 16 (instead of 13) bits are used for the break pulse 16

Appendix A CE Certificate 17

Appendix B Emission Diagram Emission with and without PLIN-LWL: 18