Safety Relay Unit G9SE Series

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

Safety Relay Unit G9SE Series

DESIGNED FOR FLEXIBILITY

Building-block power supply with system back-up options S8TS SERIES

Making Hazardous Operations Safe and Productive

NB SERIES. The feature-rich, economical HMI.» Quality colour display with LED backlighting» Complete HMI family» Comprehensive features

Expansion Unit G9SX-EX Safety 2 Instantaneous safety outputs

Smart sensor with Plug & Play Concept for fast, accurate measurement ZX-E SERIES

Safety Monitoring Relays

Safety Relay Unit (I/O Unit Type)

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

Safety Monitoring Relays

CP1L. T h e c o m p a c t m a c h i n e c o n t r o l l e r. » A d v a n c e d m o t i o n f u n c t i o n a l i t y

H3DS Timers. Great features - small dimensions

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

NE1A/DST1. DeviceNet Safety System

G9SX SAFETY CONTROLLER

Sysmac Automation Platform

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

Tecnología en Electrónica y Control SRL Ficha Técnica

G9SA. Safety Relay Unit. The G9SA Series Offers a Complete Line-up of Compact Units. Model Number Structure

DEVICENET SAFETY. Optimizing industrial and safety networking. b r e a k t h r o u g h t o s e a m l e s s s a f e c o n t r o l s y s t e m s

MSR178DP. Description. Features. Specifications

Screw-Less Clamp solutions SOCKETS TIMERS

FP-PS-4. Features. Installation

DYALOX INDUSTRIAL PC

For full product information, visit Use the SpeedSPEC Code for quick access to the specific web page.

NQ HMI SERIES. Create and Operate. Powerful HMI features High quality display Create applications quickly

G9SX-LM. Low-speed Monitoring Unit. Low-speed Monitoring Function Ensures Safety for Maintenance Work. Model Number Structure.

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are

Vital. Safety controller. Approvals: Control of: Features: Entire safety system based on the dynamic safety circuit.

Innovations in Panel Building New value for control panels

HR1S-AC Safety Relay Modules

A new strategy in machine control CJ1-SERIES

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Number of input channels

THE NEW RC8. English. Connect to many devices such as... PLCs. Cameras Grippers...and many more.

E-T-A PowerPlex Bus System for Marine Applications

Datasheet - SRB 402EM-24V

Datasheet - SRB 301LC/B-24V

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

E-STOP relays, safety gate monitors

ZFV VISION SENSOR. E a s y v i s i o n Te a c h & G o. » Easy colour v i s i o n. » S c a l a b l e a n d f l e x i b l e

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

Datasheet - SLB 200-C04-1R

Datasheet - MZM 100 B ST2-1P2PW2RE-A

Safety. Detection. Control. MAGNUS RFID ENG - REV

Safety controller unit B1 /

NX integrated safety System configuration. Integrated safety into machine automation

Datasheet SRB301ST 24V (V.2)

Safety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C

E2Q4 Square Proximity Sensor

Thread length (overall length) material

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

E-STOP relays, safety gate monitors

Safety Control. Safety. Selection Guide Safety Relay HR1S-AC Safety Relay HR1S-AF

Safety Control. Safety.

INDUSTRIAL RELAYS. Quality relays for every industrial application

E-STOP relays, safety gate monitors

Magnetically Actuated Safety Interlock Switches

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Worldwide reliable and easy operation

SpectraGuard Sensor SS-300-AT-C-50 Technical Specifications

CONFIGURABLE SAFETY RELAYS

Service withdrawal: Selected IBM ServicePac offerings

cfp-rly-421 Features Installing the cfp-rly-421 FieldPoint Operating Instructions Eight-Channel SPST Relay Module

Copyright 2011 Rockwell Automation, Inc. All rights reserved. Next Generation Guardmaster Safety Relay Platform Overview

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

INSTALLATION INSTRUCTIONS LFH160 Cable

XCSRC10M12 Safety RFID contactless switch - Single model - Unique pairing

Datasheet - MZM 100 B ST-1P2PW2REM-A

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

V4000 Press Brake Safety camera system

Reduced wiring system. PROFIBUS-DP Compatible GW unit. Operation Manual EX510-GPR1. URLhttp://

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Magnetically Actuated Safety Interlock Switches

IBM offers Software Maintenance for additional Licensed Program Products

NI CB-37F-LP. Introduction INSTALLATION GUIDE. Connector Block for 37-Pin D-Sub Devices

must Operate Voltage (V)

Pluto AS-i. Safety PLC. Approvals: Control of: Features:

Online data sheet. C4C-EB10530A10000 detec SAFETY LIGHT CURTAINS

SafeC S to MSR127 Conversion

E5CC/E5EC TEMPERATURE CONTROLLER

XtraDrive. XtraDrive-DP. Next generation intelligent servo driver with integrated positioner. l i ci. with embedded PROFIBUS

NI 6521 Specifications

Transcription:

Safety relay units G9SE Series Ultra slim size: 17.5 mm and 22.5 mm Screwless terminals LED status indicators industrial.omron.eu/g9se

2 3 Safety relay units - G9SE Series A standalone approach to safety applications The G9SE series of safety relay units offer a standalone approach for safety applications. Screwless terminals The screwless front terminals save time and effort by offering better visibility when making connections. Benefits: Slim design saves mounting space. Screwless terminals reduce installation time. LED status indicators provide quick and clear distinction of operational status and errors. Fast response time. Fast screwless push-in connections No tool required for connections. Benefits: Reduce installation time by >50%. Unobstructed access to the front of the unit. Clear and identifiable terminal markings. No connection problems caused by shock and vibration. Insert a flat-blade screwdriver, and remove the ferrule. LED status indicators When the G9SE detects an error, such as a short circuit or a broken wire, the indicators will signal where the error has occurred. This minimizes downtime as it helps to identify the cause when equipment stops. Ultra slim size: 17.5 mm and 22.5 mm The G9SE, is the thinnest safety relay unit in the industry*. Input Error Output Error Output Error Short circuit between safety inputs Fault of internal relay OFF-delay setting error * as of April 2015.

4 5 Safety relay units - G9SE Series Applications Shrink wrap machine - Packaging line Escalator / Elevator The G9SE monitors an E-Stop safety function according to EN ISO 13850. Once the E-Stop is pressed the G9SE will immediately bring the machine to the safe state by quickly transmitting a signal between the safety components. The G9SE fulfill the requirements for EN 81-1 and EN 81-2 which is needed to cover the lift, elevator and escalator applications. Safety control Safety control Emergency stop Safety relay unit G9SE Safety relay unit G9SE Emergency stop switch A22E Safety control Emergency stop switch A22E Door position and open/close detection Safety limit switch D4B Small safety limit switch D4N/D4F

7 Safety relay units - G9SE Series G9SE range 3 different models of the G9SE are available to meet your safety application requirements. These models provide options for different safety output configurations and adjustable OFF-delay times. All models are compatible with a variety of safety devices such as E-stops, door switches and opto sensors. G9SE-201 G9SE-401 G9SE-221-T05/T30 The G9SE completes our comprehensive product lineup to fulfill every safety application. Product Line-up Hardwired and programmable safety control E-Stop E-Stop Door switch Door switch Door switch Opto sensor Opto sensor Opto sensor 2 safety output contacts 4 safety output contacts 2 safety output contacts Product Lineup E-Stop Stand-alone Controllers G9SP NX-S Integrated Safety Controller NX G9SE Hard-wired 6 G9SX G9SR Small < Application complexity > Large 2 safety OFF delay contacts The G9SE is in compliance with with the following standards: EN ISO13849-1: 2008 PL e Safety Category 4, IEC/EN 60947-5-1, IEC/EN 62061 SIL3, EN 81-1, EN81-2, UL508, CAN/CSA C22.2 No.14. The Functional Safety Type Approved test mark has been granted for the G9SE series by the TÜV Rheinland Group. This product has been examined and meets defined safety levels to protect individuals, the environment and goods of value.

8 A complete standalone Safety Relay Unit family - G9SR Safety control that meets every requirement GLOBAL application knowledge partner The wide safety relay and controller range on offer ensures that there is always the right product available for your machine, whatever the application. Make the perfect choice from just five product families using the quick selection guide. Start Integrated safety NX NX standalone safety controller G9SP series G9SX series G9SR series Standalone controllermore than 20 safety inputs or 16 safety outputs Compact standalonecontroller Dedicated Pre-defined Safety Functions Safety application with more than 1 safety input G9SE series

G9SE Safety relay units Compact safety relay units for general safety monitoring applications G9SE-family offers a complete line-up of compact units. Modules with two safety contacts, four safety contacts and OFF-delay timing are available on slim-size housing. Simple front side wiring using screw-less terminals. 17.5 or 22.5 mm width to save mounting space 15 ms max. response time Safe OFF delay function up to PLe Easy maintenance with status indicators Approved standards: EN ISO13849-1: 2008 PLe Safety Category 4, IEC/EN 60947-5-1, IEC/EN 62061 SIL3, EN 81-1, EN81-2, UL508, CAN/CSA C22.2 No.14 Ordering information Safety outputs Auxiliary outputs *1 Max. OFF-delay time *2 Rated voltage Order code Instantaneous OFF-delayed DPST- 1 PNP transistor output 24 VDC G9SE-201 4PST- G9SE-401 DPST- DPST- 5 s G9SE-221-T05 DPST- DPST- 30 s G9SE-221-T30 *1 PNP transistor output *2 The OFF-delay time can be set in 16 steps as follows: T05: 0/0.1/0.2/0.3/0.4/0.5/0.6/0.7/0.8/1/1.5/2/2.5/3/4/5 s T30: 0/1/2/4/5/6/7/8/9/10/12/14/16/20/25/30 s Specifications Ratings Power Input Item G9SE-201 G9SE-401 G9SE-221-T_ Rated supply voltage 24 VDC Operating voltage range 15% to 10% of rated supply voltage Rated power consumption *1 Power consumption of loads not included. 3 W max. 4 W max. Outputs Item G9SE-201 G9SE-401 G9SE-221-T_ Safety output OFF-delayed safety output Auxiliary output Contact output 250 VAC 5 A 30 VDC 5 A (resistance load) PNP transistor output Load current: 100 ma DC max. Characteristics Item G9SE-201 G9SE-401 G9SE-221-T_ Operating time (OFF to ON state) *1 100 ms Max. *2 Response time (ON to OFF state) *3 15 ms Max. Inputs Input current 5 ma Min. ON voltage 11 VDC Min. OFF voltage 5 VDC Max. OFF current 1 ma Max. Maximum cable length 100 m Max. Reset input time 250 ms Min. Contact outputs Contact resistance *4 100 m Mechanical durability 5,000,000 operations Min. Electrical durability 50,000 operations Min. Switching specification Inductive load (IEC/EN60947-5-1) AC15: 240 VAC 2 A DC13: 24 VDC 1.5 A Minimum applicable load 24 VDC 4 ma Conditional short-circuit current 100A *5 (IEC/EN60947-5-1) Surrounding air temperature 10 to 55 C (No freezing or condensation) *1 The operating time is the time it takes for the safety contact to close after the safety inputs and feedback-reset input are turned ON. Not includes bounce time. *2 This is in normal operation. When executing non-regular self-diagnosis for Safety output circuit, G9SE operating time become 500 ms max.. *3 The response time is the time it takes for the safety main contact to open after the safety input is turned OFF. Includes bouncetime. *4 This is initial value using the voltage-drop method with 1 A at 5 VDC. *5 Use an 8 A fuse that conforms to IEC 60127 as a short-circuit protection device. This fuse is not included with the G9SE. 9

G9SE Safety relay units Dimensions and terminal arrangement R2.3 17.5 5.6 5.6 22.5 4 111.6 109 11.4 6.6 4 3 3 124 71 73.5 Two, 4.2 dia. or M4 133 ±0.3 Terminal arrangement and LED indicators G9SE-201 G9SE-401 G9SE-221-T_ PWR PWR PWR IN1 IN1 IN1 IN2 IN2 IN2 OUT OUT OUT1 OUT2 A1 A1 A1 A2 A2 A2 T11 T11 T11 T12 T12 T12 T21 T21 T21 T22 T22 T22 T31 T31 T31 T32 T32 T32 T33 T33 T33 X1 X1 X1 13 13 14 14 23 23 24 24 13 33 37 14 34 38 23 43 47 24 44 48 Type G9SE-201 Type G9SE-401 Type G9SE-221-T_ 9.9 Mounting holes Application example Application Overview Immediately removes power to Motor M when Emergency Stop Switch S1 is pressed. The power to Motor M is kept removed until Emergency Stop Switch S1 is released and Reset Switch S2 is pressed. Evaluation example PL/safety category Model Stop category Reset PLe/4 equivalent Emergency stop pushbutton: A22E-M-02 (2NC contact) 0 Manual Push button switch (from Annex C of ISO 13849-1) Safety relay unit: G9SE-201 Contactor of rated load (from Annex C of ISO 13849-1) Note: The above PL is only the evaluation result of the example. The PL must be evaluated in an actual application by the customer after confirming the usage conditions. Wiring Example S1 S2 Feedback loop KM1 Timing chart Emergency stop switch operation KM2 Emergency stop switch S1 A1 T11 T12 T31 T32 T33 13 23 Reset switch S2 KM1, KM2 NC contact KM1, KM2 contact 24 V Power supply circuit Safety Input 1 Safety Input 2 Reset/ Feedback Input Auxiliary output Safety Output (instantaneous) Device S1: Emergency stop switch S2: Reset switch KM1, KM2: Contactor M: 3-phase motor A2 T21 T22 X1 14 24 PLC etc. KM1 KM2 KM1 KM2 M 10

11 Omron at a glance 200.000 products ranging input, logic and output Sensing, Control Systems, Visualization, Drives, Robots, Safety, Quality Control & Inspection, Control and Switching Components 7% Investment in Research & Development 37.000 Employees worldwide Innovation track record of 80 years Top 150 global patent assignee 1.200 employees dedicated to R&D 11.000 + issued and pending patents Working for the benefit of society 210 Locations worldwide 22 Countries in EMEA Industrial Automation Automotive Components Social Systems Healthcare Environmental 40% 15% 13% 11% 11% 10% Close to your needs Technical training & seminars, technical support, Automation Technology Centers, online community (MyOmron), online catalogues and technical documentation, customer service & sales support, inter-operability labs (Tsunagi), safety services, repairs.

Would you like to know more? OMRON EUROPE +31 (0) 23 568 13 00 industrial.omron.eu omron.me/socialmedia_eu Austria Tel: +43 (0) 2236 377 800 industrial.omron.at Germany Tel: +49 (0) 2173 680 00 industrial.omron.de Portugal Tel: +351 21 942 94 00 industrial.omron.pt Turkey Tel: +90 212 467 30 00 industrial.omron.com.tr Belgium Tel: +32 (0) 2 466 24 80 industrial.omron.be Hungary Tel: +36 1 399 30 50 industrial.omron.hu Russia Tel: +7 495 648 94 50 industrial.omron.ru United Kingdom Tel: +44 (0) 1908 258 258 industrial.omron.co.uk Czech Republic Tel: +420 234 602 602 industrial.omron.cz Italy Tel: +39 02 326 81 industrial.omron.it South Africa Tel: +27 (0)11 579 2600 industrial.omron.co.za Denmark Tel: +45 43 44 00 11 industrial.omron.dk Netherlands Tel: +31 (0) 23 568 11 00 industrial.omron.nl Spain Tel: +34 902 100 221 industrial.omron.es Finland Tel: +358 (0) 207 464 200 industrial.omron.fi Norway Tel: +47 (0) 22 65 75 00 industrial.omron.no Sweden Tel: +46 (0) 8 632 35 00 industrial.omron.se France Tel: +33 (0) 1 56 63 70 00 industrial.omron.fr Poland Tel: +48 22 458 66 66 industrial.omron.pl Switzerland Tel: +41 (0) 41 748 13 13 industrial.omron.ch More Omron representatives industrial.omron.eu CD_EU_01_G9SE Although we strive for perfection, Omron Europe BV and/or its subsidiary and affiliated companies do not warrant or make any representations regarding the correctness or completeness of the information described in this document. We reserve the right to make any changes at any time without prior notice.