Innovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s

Similar documents
Excel Power Distribution

PDU. InfraPower POWER AUSTI AUSTIN AUSTIN AUSTIN 3 PHASE WSI WI WS W MD BASIC. Enclosure Power Management Solutions

Intelligent PDUs. Best in Class Outlet Density Optimal Form Factors Superior Reliability

CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. Available in Basic, Metered, and Smart PDU models.

PDU - Overview / Non-Intelligent PDU s

Intelligent Power Distribution

Polar PDUs POWER MANAGEMENT

Switched, Outlet Level Monitoring

How do I... If you manage a datacenter, we have a solution for you. Sentry : Cabinet Power Distribution Unit Product Family : Metered CDU.

RCOBN PH6TL21-D Power Monitoring, Outlet Level. Part Number

CS-10H0A413H3 (Master) Key Features. CL-10H0A413H3 (Link)

YourPDU. by Schleifenbauer. This PDF has been optimised for viewing with Acrobat Reader. Click here to download it for free.

PDU Inspired by Your Data Center. W IEC PDU Series

CS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link)

Intelligent Power Distribution

G GRCOW PH6PS6-D-IP44 Power Monitoring, Outlet Level. Part Number

PDU Solutions. PDU Solutions

ipdu Pocket Guide INTERNATIONAL

Power Distribution. For technical support call Online catalog available at leviton.com 461

ipdu Pocket Guide NORTH AMERICA

Tripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3.

The -3Ph extension on a product indicates a 3 Phase power product.

Tripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3.

B&R Enclosures. INTELLIGENT PDUs

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

Eaton Open Data Centre Solutions. Kari Koli

CS-24VD-L30MA (Master) Key Features. CL-24VD-L30MA (Link)

PE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU

Inspired by Your Data Center. Intelligent W Series : 3 - Phase 400V

Power Distribution Units for Data Centers

PE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU. 8 outlets. 20A (UL derated 16A) / 16A. Outlet Power Measurement

Inspired by Your Data Center. Intelligent W Series : 3 - Phase 208V

Power Monitoring (RCX)

Inspired by Your Data Center. 1-Phase Intelligent PDU US NEMA Outlet 110V

Power Distribution Units for Data Centers

Engineering and Manufacturing Excellence in Data Centre Infrastructure

Power Distribution Unit

Switched XPDU. 15A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Power Monitoring in the Data Centre

25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC A Red 415V, 0U, TAA

User Manual. Per Port Monitoring Models

Inspired by Your Data Center. 1-Phase Intelligent PDU Outlets for 230V

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

5.8kW Single-Phase Switched PDU, 208/240V Outlets (8 C13 & 6 C19), L6-30P, 15ft Cord, 2U Rack-Mount, TAA

Intelligent Power Distribution

20 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units

16 and 32 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units

QuickSpecs. HPE Metered and Switched Power Distribution Units (PDU) Overview

30, 50, and 60 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units

ECO PDU. Features. PE5220sA

KWX PDU. Inteligent, Rack Mounted, Power Distribution Units. Innovation in Intelligent Power. Dry Connector. Energy Display. Water Logging.

Models. Specifications

ECO PDU Power Distribution Unit

Inspired by Your Data Center. 1-Phase Intelligent PDU IEC Outlet 208V / 230V

Intelligent W Series : 3 - Phase 208V 20A / 30A. Inspired by Your Data Center

PE8216/PE8324. Energy Intelligence Solutions

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

Liebert MPH TM Managed Rack-PDU Systems monitoring and control

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

All power outlet units include 10' power cords, mounting brackets, screws, unit packaging:

Modular PDU Smart metering for your IT

Managed Rack PDU MPH2 More efficient Simpler Better

Specification Sheet: HT SERIES

ipdu Pocket Guide INTERNATIONAL

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 4

Basic PDU Modules SW Meter PDU SW Meter Switch PDU SW Three Phase PDU. How to install 11-12

C2W36CE-DQME2M99 (Master) C2X36CE-DQME2M99 (Expansion) Key Features

Basic In-Line Metered Metered Input. Metered Outlet Switched Managed. Power distribution for IT equipment. epdu. G3 Platform. New

OPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES

Energy Management Solutions

PN5212/PN5320/PN7212/PN7320

ECO PDU PE7108/PE7208

Power Control and Distribution

Product Brochure. Eaton epdu G3 Managed

Model# ANI SWH. Ver. 1.1

Sentry Metered, Smart, and Switched High Density 30 Receptacle 208VAC, 3-Phase 30A Products

Product Brochure. Eaton epdu G3 Managed

Stripes. 19" Outlet Stripes Desktop Outlet Stripes IP Power Distribution Units IP Monitoring Units UPS...

ECO PDU PE5108/PE5208

16 and 32 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units

Intelligent-Remote Monitoring (3) Environmental Port (4) Power Outlet Level (5)

Rack- and Panel-Mount Power Distribution Units (PDUs)

IT power distribution Power distribution units (PDU) Basic. Versions available:

Deploying High Power to IT Equipment Racks

POWER DISTRIBUTION UNITS

IPDU-A Series User Manual. IPDU-A Series User Manual

30 Amp PanView iq TM (PViQ TM ) Switched with Per Outlet Monitoring and Environmental Power Outlet Units. specifications. technical information

New Product Release. Integrated Intelligent Power Distribution.

IBM eserver System x and BladeCenter IBM DPI PDU+ Power Distribution Units. 10/9/ IBM Corporation

Frequently Asked Questions

PowerPak 2 Power Distribution Unit. Flexible. Configurable. Intelligent. Safe.

VT608 / Switched PDU with 8 outlets

Rack- and Panel-Mount Power Distribution Units (PDUs)

WIRELESS ENVIRONMENTAL MONITORS

Geist EMEA. Geist USA. Geist APAC

How do I... If you manage a datacenter, we have a solution for you.

QuickSpecs. HP Remote Monitoring Power Distribution Units. Overview

VT825 / Environmental Monitoring unit. Environmental Infrastructure monitoring

Deploying High Power to IT Equipment Racks

Switched econnect PDU

Transcription:

Structure Source PDU s Innovative Power Engineering High Quality Power Distribution for the Data Centre structure source Making the complex, simple

structure source product range Rack and Server Power Distribution Units Structure Source Power Distribution Units are designed to provide reliable, power distribution combined with highly accurate monitoring and control for IT equipment in the data centre. Optimise and utilise all available power and control the operational expenditure involved in running a data centre. Rack and Server Power Distribution Units Structure Source PDU s offer real time remote power monitoring of current (amps), voltage, power (kva, kw) and energy consumption (kwh) with a high grade accuracy that enables you to track, trend, analyse and utilise all your available power. You can then choose your level of control, remotely switch outlets for full control and remote reboot, or combine outlet monitoring with switching to fully manage the rack power. Power distribution and monitoring through Structure Source PDUs help to ensure you have the power you need, where you need it. Choosing from SMART PIM (Per inlet monitoring PDU s), SMART POM (Per outlet monitoring PDU s), SMART POMS (Per outlet monitored and switched PDU s) you know if you are reaching your capacity, or can plan for growth, knowing confidently if you are able to add more servers or capacity and, if so, where. Structure Source Product Range Basic PDU Circuit Breakers Local Inlet Power Monitoring Remote Inlet Power Monitoring Outlet Power Monitoring Outlet Switching Environmental Monitoring Set up alarms, access security Metered PDU Smart PIM (Per inlet monitored PDU) Smart POM (Per outlet monitored PDU) Smart POMS (Per outlet monitored & switched PDU) Structure Source Power management solutions enable data center and facilities managers to: Efficiently manage power resources Improve uptime and staff productivity Optimise the capacity planning decisions Energy saving

structure source the Structure Source technology IP ACCESS AND TECHNOLOGY Support HTTP/HTML, SNMP V1, 2, 3, IPv&6, DHCP, Modbus Over IP, Telnet. VERSATILE CONNECTION PORTS LIGHT ALUMINIUM CHASIS Light and excellent heat dissipation Large variety of profile colours available. Versatile mounting options to fit on the major Server Rack manufacturers. 10-100 Mbps Ethernet (RJ-5) Environmental RJ5 port mini USB for firmware update and debug Daisy chain RJ5 IN/T. SMART LCD DISPLAY Shows Input power parameters Scroll individual outlet (V,A,PF,W,kWh) Screen turn orientation according PDU position. DAISY CHAIN HIGH QUALITY ELECTRICAL COMPONENTS UL89 BRANCH CIRCUITS Meet latest UL branch protection standards Independent VDE approved for European low profile Magnetic hydraulic breaker. Wide range of power sockets including Schuko CEE 7/ UTE CEE7/5, UK BS1363, AS/NZS3112, SEVT13, SEVT23, C13 lock, C19 lock, UL and VDE approved sockets. Busbar copper connections, prevents hot points across the whole electrical line. The Daisy Chain to monitor and manage up to PDU s with a single IP address. ENVIRONMENTAL SENSORS All in one temperature and humidity sensor supports 2 digital inputs for door open sensor, water leak, smoke sensor, air flow and vibration sensor.

The Structure Source Basic PDU s provides a simple solution where reliable power distribution for equipment racks and other data center applications is needed. This PDU s provide both power distribution and branch circuit protection. Structure Source has a full range of choices, from 6A to 63A rating for a single phase and three phase. For outlet connections, the Basic PDU s has a wide range of socket options from IEC sockets (C13 and C19) to the different national outlet standard types such as (Schuko) CEE7/, (UTE) CEE7/5, UK BS1363, AS/NZS3112 and NEMA. RACK MNTABLE Includes horizontal, vertical, and toollessmount options. BRANCH CIRCUIT PROTECTION All PDU s meet the required branch circuit when power is up to, other protections like individually fused outlets are available upon demand. Basic PDU s BASIC PDU S Technology Part Number Mounting Rating (A) Outlet Type Output Type Input Type BASIC EN-612-C1-H 10A 12C13 C1 plug BASIC EN-612-C20-H 12C13 C20 plug BASIC EN-612--H 12C13 BASIC EN-O-612--H 12C13 IEC60309 plug BASIC EN-616--H 16C13 BASIC IEC-606--H 6C19 BASIC ENIEC-6200--V 20C13+C19 BASIC ENIEC-6200--V 20C13+C19 IEC60309 plug BASIC ENIEC-63606--V 36C13+6C19 BASIC ENIEC-O-63606--V 36C13+6C19 IEC60309 plug BASIC ENIEC-63606--3P-V 380V 36C13+6C19 BASIC ENIEC-63606--3P-V 380V 36C13+6C19 IEC60309 plug The Structure Source Metered is a PDU with local input current monitoring, which allows network engineers to utilise the PDU s True RMS Power Monitor to precisely measure the current (in amps) that network devices are drawing on the power circuit. As new servers and devices are added to the power drop, the impact on the cumulative current draw can be observed immediately. This allows the engineer to safely load each circuit to its maximum allowable load capacity without the danger of overloading the power circuit. RACK MNTABLE Includes horizontal, vertical, and toollessmount options. BRANCH CIRCUIT PROTECTION All PDU s meet the required branch circuit when power is up to, other protections like individually fused outlets are available upon demand. LOCAL CURRENT DISPLAY LED current display true RMS meter to prevent overload on critical environments where high load is required and the current draw is close to the maximum amperage draw of the strip. Metered PDU s

METERED PDU S Technology Part Number Mounting Rating (A) Outlet Output Type Input Type Type: Qty METERED IEC EN-M-612--H 12C13 METERED IEC EN-O-M-612--H 12C13 IEC60309 plug METERED IEC EN-M-616--V 16C13 METERED IEC EN-O-M-616--V 16C13 IEC60309 plug METERED IEC ENIEC-M-6200--V 20C13+C19 METERED IEC ENIEC-0-M-6200--V 20C13+C19 IEC60309 plug METERED IEC ENIEC-M-63606--V 36C13+6C19 METERED IEC ENIEC-O-M-63606--V 36C13+6C19 IEC60309 plug METERED IEC ENIEC-M-63606--3P-V 380V 36C13+6C19 3phase METERED IEC ENIEC-O-M-63606--3P-V 380V 36C13+6C19 IEC60309 plug 3phase METERED SCHUKO GN-M-620--V 20 Schuko METERED SCHUKO GN-0-M-620--V 20 Schuko IEC60309 plug METERED UTE FN-M-620--V 20 UTE METERED UTE FN-O-M-620--V 20 UTE IEC60309 plug METERED UK BN-M-620--V 20 UK METERED UK BN-M-620--V 20 UK IEC60309 plug METERED AS/NZS3112 AS-M-620--V 20 AS/NZS3112 METERED AS/NZS3112 AS-O-M-620--V 20 AS/NZS3112 IEC60309 plug The Smart PIM PDU range provides highly reliable power distribution with the latest intelligent power monitoring. It offers both a clear local LCD display and IP monitoring of the total overall power and cabinet environmental conditions. Its intuitive interface allows you to view Amps, Volts, Watts, Power Factor, kwh, temperature and humidity levels via any web browser, or receive alarms and alerts via SNMP or an email when conditions exceed their defined thresholds. The Smart PIM PDU family has the capability to define master and slave units, allowing daisy chaining of multiple units. A single IP address can then be used across different power circuits, reducing the need for multiple IP addresses. RACK MNTABLE Includes horizontal, vertical, and toollessmount options. DAISY CHAIN The Daisy Chain to monitor and manage up to PDU s with a single IP address. BRANCH CIRCUIT PROTECTION All PDU s meet the required branch circuit when power is up to, other protections like individually fused outlets are available upon demand. SMART LCD DISPLAY Shows Input power parameters Scroll individual outlet (V,A, PF,W,kWh) Screen turn orientation according to PDU position. SMART PIM Smart Per Inlet Monitored Smart PIM PDU s IP ACCESS TECHNOLOGY Support HTTP/HTML, SNMP V1, 2, 3, IP V &6, DHCP, Modbus Over IP, Telnet. mount options. ENVIRONMENTAL SENSORS All in one temperature and humidity sensor supports 2 digital inputs for door open sensor, water leak, smoke sensor, air flow and vibration sensor.

SMART PIM PDU S Technology Part Number Mounting Rating (A) Outlet Output Type Input Type Type: Qty PER INLET MONITORED IEC ENIEC-PIM-60120--H 12C13+C19 PER INLET MONITORED IEC ENIEC-O-PIM-60120--H 12C13+C19 IEC60309 plug PER INLET MONITORED IEC ENIEC-PIM-60200--V 20C13+C19 PER INLET MONITORED IEC ENIEC-O-PIM-6200--V 20C13+C19 IEC60309 plug PER INLET MONITORED IEC ENIEC-PIM-63606--V 36C13+6C19 PER INLET MONITORED IEC ENIEC-O-PIM-63606--V 36C13+6C19 IEC60309 plug PER INLET MONITORED IEC ENIEC-PIM-63606--3P-V 380V 36C13+6C19 PER INLET MONITORED IEC ENIEC-O-PIM-63606--3P-V 380V 36C13+6C19 IEC60309 plug PER INLET MONITORED SCHUKO GN-O-PIM-6012--H 8 o 2 IEC60309 plug PER INLET MONITORED SCHUKO GN-PIM-620--V 20 Schuko PER INLET MONITORED SCHUKO GN-O-PIM-620--V 20 Schuko IEC60309 plug PER INLET MONITORED UTE FN-O-PIM-6012--H 8 o 2 IEC60309 plug PER INLET MONITORED UTE FN-PIM-620--V 20 UTE PER INLET MONITORED UTE FN-O-PIM-620--V 20 UTE IEC60309 plug PER INLET MONITORED UK BN-PIM-6012--H 8 o 2 IEC60309 plug PER INLET MONITORED UK BN-PIM-620--V 20 UK PER INLET MONITORED UK BN-PIM-620--V 20 UK IEC60309 plug PER INLET MONITORED AS/NZS3111 AS-O-PIM-6012--V 8 o 2 IEC60309 plug PER INLET MONITORED AS/NZS3112 AS-PIM-620--V 20 AS/NZS3112 PER INLET MONITORED AS/NZS3112 AS-O-PIM-620--V 20 AS/NZS3112 IEC60309 plug The Smart POM PDU range provides highly reliable power distribution with the latest intelligent power monitoring. It offers both a clear local LCD display and IP monitoring of the total overall power, power at each individual outlet and cabinet environmental conditions. By monitoring each single outlet and the overall power it gives a full view of power use in your cabinet. Its intuitive interface allows you to view Amps, Volts, Watts, Power Factor, kwh, temperature and humidity levels via any web browser, or receive alarms and alerts via SNMP or email when conditions exceed their defined thresholds. The Smart POM PDU family has the capability to define a master and slave units, allowing daisy chaining of multiple units. A single IP address can be used across different power circuits, reducing any need for multiple IP addresses. RACK MNTABLE Includes horizontal, vertical, and toollessmount options. DAISY CHAIN The Daisy Chain to monitor and manage up to PDU s with a single IP address. BRANCH CIRCUIT PROTECTION All PDU s meet the required branch circuit when power is up to, other protections like individually fused outlets are available upon demand. SMART LCD DISPLAY Shows Input power parameters Scroll individual outlet (V,A, PF,W,kWh) Screen turn orientation according to PDU position. SMART POM Smart Per Outlet Monitored Smart POM PDU s IP ACCESS TECHNOLOGY Support HTTP/HTML, SNMP V1, 2, 3, IP V&6, DHCP, ModbusOver IP, Telnet. mount options. ENVIRONMENTAL SENSORS All in one temperature and humidity sensor supports 2 digital inputs for door open sensor, water leak, smoke sensor, air flow and vibration sensor.

SMART POM PDU S Technology Part Number Mounting Rating (A) Outlet Output Type Input Type Type: Qty PER TLET MONITORED IEC ENIEC-POM-60120--H 12C13+C19 PER TLET MONITORED IEC ENIEC-CB-POM-60120--H 12C13+C19 IEC60309 plug PER TLET MONITORED IEC IEC-POM-60120--H 12C19 PER TLET MONITORED IEC IEC-CB-POM-6012--H 12C19 IEC60309 plug PER TLET MONITORED IEC ENIEC-POM-5200--V 20C13+C19 PER TLET MONITORED IEC ENIEC-CB-POM-5200--V 20C13+C19 IEC60309 plug PER TLET MONITORED IEC ENIEC-POM-53606--V 36C13+6C19 PER TLET MONITORED IEC ENIEC-CB-POM-53606--V 36C13+6C19 IEC60309 plug PER TLET MONITORED IEC ENIEC-POM-53606--3P-V 380V 36C13+6C19 PER TLET MONITORED IEC ENIEC-CB-POM-53606--3P-V 380V 36C13+6C19 IEC60309 plug PER TLET MONITORED SCHUKO GN-CB-POM-6012--H 12 IEC60309 plug PER TLET MONITORED SCHUKO GN-POM-5020--V 20 Schuko PER TLET MONITORED SCHUKO GN-CB-POM-5020--V 20 Schuko IEC60309 plug PER TLET MONITORED UTE FN-CB-POM-6012--H 12 IEC60309 plug PER TLET MONITORED UTE FN-POM-5020--V 20 UTE PER TLET MONITORED UTE FN-CB-POM-5020--V 20 UTE IEC60309 plug PER TLET MONITORED UK BN-CB-POM-6012--V 12 IEC60309 plug PER TLET MONITORED UK BN-POM-5020--V 20 UK PER TLET MONITORED UK BN-CB-POM-5020--V 20 UK IEC60309 plug PER TLET MONITORED AS/NZS 3112 AS-CB-POM-6012--H 12 IEC60309 plug PER TLET MONITORED AS/NZS 3112 AS-POM-5020--V 20 AS/NZS3112 PER TLET MONITORED AS/NZS 3112 AS-CB-POM-5020--V 20 AS/NZS3112 IEC60309 plug The Smart POMS PDU s range provide highly reliable power distribution with the latest intelligent power monitoring. It offers both a clear local LCD display and IP monitoring of the power cabinet environmental conditions. It offers our maximum power monitoring and functionality, giving both overall power conditions, power monitoring per outlet, cabinet environmental conditions all combined with the ability to switch on or off each individual outlet remotely. Using the intuitive interface you can view Amps, Volts, Watts, Power Factor, kwh, temperature and humidity levels via any web browser, or receive SNMP based alarms and email alerts when conditions exceed the defined thresholds. Controlling each outlet switching allows the user to reboot each outlet immediately or in a specific delayed sequence. The Smart POMS PDU family has the capability to define a master and slave units, allowing daisy chaining of multiple units. A single IP address can then be used across different power circuits, reducing any need for multiple IP addresses. DAISY CHAIN The Daisy Chain to monitor and manage up to PDU s with a single IP address. IP ACCESS TECHNOLOGY Support HTTP/HTML, SNMP V1, 2, 3, IP V &6, DHCP, Modbus Over IP, Telnet. mount options. SMART LCD DISPLAY Shows Input power parameters Scroll individual outlet (V,A, PF,W,kWh) Screen turn orientation according to PDU position. ENVIRONMENTAL SENSORS All in one temperature and humidity sensor supports 2 digital inputs for door open sensor, water leak, smoke sensor, air flow and vibration sensor. SMART POMS Smart Per Outlet Monitored & Switched Smart POMS PDU s

SMART POMS PDU S Technology Part Number Mounting Rating (A) Outlet Type: Qty Output Type Input Type PER TLET MONITORED & SWITCHED IEC ENIEC-POMS-60120--H 12C13+C19 PER TLET MONITORED & SWITCHED IEC ENIEC-CB-POMS-60120--H 12C13+C19 IEC60309 plug PER TLET MONITORED & SWITCHED IEC ENIEC-POMS-6012--H 12C19 PER TLET MONITORED & SWITCHED IEC ENIEC-CB-POMS-6012--H 12C19 IEC60309 plug PER TLET MONITORED & SWITCHED IEC ENIEC-POMS-5200--V 20C13+C19 PER TLET MONITORED & SWITCHED IEC ENIEC-CB-POMS-5200--V 20C13+C19 IEC60309 plug PER TLET MONITORED & SWITCHED IEC ENIEC-POMS-503606--V 36C13+6C19 PER TLET MONITORED & SWITCHED IEC ENIEC-CB-POMS-503606--V 36C13+6C19 IEC60309 plug PER TLET MONITORED & SWITCHED IEC ENIEC-POMS-503606--3P-V 380V 36C13+6C19 PER TLET MONITORED & SWITCHED IEC ENIEC-CB-POMS-503606--3P-V 380V 36C13+6C19 IEC60309 plug PER TLET MONITORED & SWITCHED SCHUKO GN-CB-POMS-6012--H 12 IEC60309 plug PER TLET MONITORED & SWITCHED SCHUKO GN-POMS-5020--V 20 Schuko PER TLET MONITORED & SWITCHED SCHUKO GN-CB-POMS-5020--V 20 Schuko IEC60309 plug PER TLET MONITORED & SWITCHED UTE FN-CB-POMS-6012--H 12 IEC60309 plug PER TLET MONITORED & SWITCHED UTE FN-POMS-5020--H 20 UTE PER TLET MONITORED & SWITCHED UTE FN-CB-POMS-5020--V 20 UTE IEC60309 plug PER TLET MONITORED & SWITCHED UK BN-CB-POMS-6012--H 12 IEC60309 plug PER TLET MONITORED & SWITCHED UK BN-POMS-5020--V 20 UK PER TLET MONITORED & SWITCHED UK BN-CB-POMS-5020--V 20 UK IEC60309 plug PER TLET MONITORED & SWITCHED AS/NZS 3113 AS-CB-POMS-6012--H 12 IEC60309 plug PER TLET MONITORED & SWITCHED AS/NZS 3112 AS-POMS-5020--V 20 AS/NZS 3112 PER TLET MONITORED & SWITCHED AS/NZS 3112 AS-CB-POMS-5020--V 20 AS/NZS 3112 IEC60309 plug Do your own custom PDU Structure Source PDU s can be custom made and built in days, this allows you to specify your power density and monitoring requirements, together with inputs and outputs. The sockets available are Schuko, UTE, UK, IEC (C13 and C19) locking version also available to customise are Basic, Metered, PIM (per inlet monitored), POM (per outlet monitored), POMS (per outlet monitored and switched). +(0)1582 235 000 www.structuresource.com 2A Hollybush Lane, Harpenden. AL5 AT