Issue 11 Page 1 of 5 Model Selection Guide Instructions Consult Steps to Selecting Appropriate Conductivity Instrumentation and Cells before making selections below. Select the desired key number. The arrow to the right marks the selection available. Make one selection per table, using the column below the proper arrow. A dot denotes unrestricted availability. A letter denotes restricted availability. Restrictions follow Table III. Key Number I II III _ - - _ - _ KEY NUMBER Selection Availability Description 7082 Analyzer 07082 TABLE I RANGE, POWER, OUTPUT (CONDUCTIVITY MEASUREMENTS) Range Power Output 0-1 V & 0-10 V 13 Wide Range - Single Cell 120/240 VAC 0-1 V & 0-10 V 4-20 ma 14 None 15 Standard Range - Single Cell 120/240 VAC 0-1 V & 0-10 V 4-20 ma 16 Power Plant Function 0-1 V & 0-10 V 17 Standard Range - Single Cell 120/240 VAC 0-1 V & 0-10 V 4-20 ma 18 None 19 0-1 V & 0-10 V 4-20 ma 22 Wide Range - Dual Cell 120/240 VAC Two 4-20 ma 23 Three 4-20 ma 24 None 25 0-1 V & 0-10 V 4-20 ma 26 Standard Range - Dual Cell 120/240 VAC None 27 Two 4-20 ma 28 Three 4-20 ma 29 Table I continued on following page
Page 2 of 5 07082 TABLE I (continued) Selection RANGE, POWER, OUTPUT (CONDUCTIVITY MEASUREMENTS) Range Power Output Standard Range - Single Cell 120/240 VAC 0-1 V & 0-10 V 4-20 ma 72 None 82 Wide Range - Single Cell 120/240 VAC 0-1 V & 0-10 V 4-20 ma 73 Standard Range - Dual Cell 120/240 VAC Two 4-20 ma 74 None 83 Standard Range - Single Cell 120/240 VAC 0-1 V & 0-10 V 4-20 ma 81 Power Plant Function INPUT, POWER, OUTPUT (ph/orp MEASUREMENTS) Input Power Output 0-1 V & 0-10 V 10 0-1 V & 0-10 V 4-20 ma 11 ph from External Preamp 120/240 VAC None 12 Two 4-20 ma 20 Three 4-20 ma 21 Direct Glass/Antimony ph/orp 0-1 V & 0-10 V 30 Electrode, Internal Preamp 120/240 VAC 0-1 V & 0-10 V 4-20 ma 31 None 32 Direct DURAFET ph Electrode, 120/240 VAC 0-1 V & 0-10 V 4-20 ma 41 Internal Preamp ph from External Preamp 120/240 VAC 0-1 V & 0-10 V 4-20 ma 70 None 77 Two 4-20 ma 78 Direct Glass/Antimony ph/orp Electrode, Internal Preamp 120/240 VAC 0-1 V & 0-10 V 4-20 ma 71 None 80 Direct DURAFET ph Electrode, Internal Preamp 120/240 VAC 0-1 V & 0-10 V 4-20 ma 76 0.001 to 1990 X 10 PPB or PPM 120/240 VAC 0-1 V & 0-10 V 4-20 ma 34 0.001 to 1990 X 10 PPB or PPM 120/240 VAC 0-1 V & 0-10 V 4-20 ma 75
Page 3 of 5 TABLE II OPTIONS Tagging None Linen Customer I.D. Tag Limit to 3 lines, 22 spaces per line 07082 Selection 0 1 Stainless Steel Customer I.D. Tag 2 Limit to 3 lines, 22 spaces per line Power Standard Factory Setting _ 0 _ Factory Set 240 Volt Operation _ 1 _ None 0 Additional Output Relays Two Additional Output Relays 1 b (analyzer comes with a total of 4 relays but no outputs) Two Additional Output Relays, 2 b Hermetically Sealed, (analyzer comes with a total of 4 relays and a 0-1V, 0-10V, or 4-20mA output) Future None _ 0 _ Future None 0 TABLE III Factory Use Only None 000 RESTRICTIONS Restriction Available Only With Not Available With Letter Table Selection Table Selection b I 12, 25, 27, 32 Notes: 1 Panel mounting hardware included. For pipe mounting kit order part number 084711 separately. 2 To mount 7082 in existing 7070, 7075 or 7076 panel cutout, order filler plate kit, part number 056349 separately. 3 ph Models 7082-10, 12, 20, 21, 51 and 52 can be field converted to direct electrode input by ordering a separate internal preamp for glass or Durafet electrodes: Glass/Antimony or ORP internal preamp - part number 31056374 Durafet internal preamp - part number 31080239 4 For simultaneous ph/orp measurements (not with Durafet electrodes) see electrode Model Selection Guides for proper mounting selections.
Page 4 of 5 Accessories and Replacement Parts Kit/Part Number Description Parts included in Kit Quantity PARTS COMMON TO ALL 7082 ANALYZERS 51198053-501 Miscellaneous parts for all 7082 120 volt fuse 1 controller/analyzers 240 volt fuse 1 24 volt fuse 1 case gasket 1 circuit card retainer bracket 1 plastic hinge 3 retainer screw 1 ground screw 1 079163 Power line filter kit filter cores 4 51198055-501 Panel mounting kit bracket 1 084711 Pipe mounting kit U-bolt for 1 inch pipe 1 U-bolt for 2 inch pipe 1 056349 Reducer panel kit 51198063-501 Output card: single current or voltage card 1 output 51198064-501 Output card: single current or voltage card 1 output with two additional hermetically sealed relays 51198065-501 Output card: two additional general card 1 purpose relays and no analog outputs 51198066-501 For replacement of existing card on ph/ card 1 conductivity analyzer: 2 current outputs 51198067-501 For replacement of existing card on ph/ card 1 conductivity analyzer: 3 current outputs PARTS USED BY CONDUCTIVITY 7082 ANALYZERS ONLY 51198066-503 For upgrade of conductivity analyzer card 1 Wide range: 2 current outputs prom 1 51198066-504 For upgrade of conductivity analyzer card 1 Standard range analyzer: 2 current outputs prom 1 51198067-503 For upgrade of conductivity analyzer card 1 Wide range analyzer: 3 current outputs prom 1 51198067-504 For upgrade of conductivity analyzer card 1 Standard range analyzer: 3 current outputs prom 1 51198074-501 Replacement conductivity standard range card 1 input card 51198087-501 Replacement conductivity wide range card 1 input card 51198069-501 Conductivity bezel assembly assembly 1 legend set 1 51198072-501 Conductivity LCD display assembly 1
Page 5 of 5 Accessories and Replacement Parts Kit/Part Number Description Parts included in Kit Quantity PARTS USED BY ph/orp 7082 ANALYZER ONLY 51198058-501 ph bezel assembly assembly, 1 legend set, 1 key legend 2 51198062-501 ph LCD display assembly 1 51198056-501 Internal preamp for use with glass/orp preamp 1 mounting rivets 4 51198057-501 Internal preamp for use with Durafet preamp 1 mounting rivets 4 51198066-502 For upgrade of ph analyzer card 1 Output Card: 2 current outputs prom 1 51198067-502 For upgrade of ph analyzer card 1 Output card: 3 current otuputs prom 1 51198172-501 Replacement ph input card card 1 PARTS FOR WITHDRAWN 7082 ANALYZERS 51204415-501 Output card: single current or voltage card 1 output for 24 volt 7082 ph and conductivity units 51198070-501 Output card: voltage only for 7082-10 units card 1 51198073-501 Output card: CE voltage and current for card 1 single cell 7082 conductivity units 51204416-501 Output card: two current outputs for 24 volt card 1 ph and conductivity 7082 units 51198054-501 Battery kit for single cell 7082 conductivity battery 1 units jumpers 3 retainer 1 51204414-501 Power supply PWA for 24 volt ph and assembly 1 conductivity 7082 51204418-501 Input card: single cell 7082 conductivity card 1 units preamp-to-instrument cable for 7758-06 7773-70, 7774-10, -50, -70, and -90, and all 7777 mountings 31075723 20 ft length with quick disconnect and cable 1 51309677-001 50 ft length with quick disconnect and cable 1 51309677-002 100 ft length with quick disconnect and cable 1 51309677-003 200 ft length with quick disconnect and cable 1 pre-amp-to-instrument cables for 7758-01, 05, 7773-10, -12, -50, -52, -60, -62, and 7774-30, 60, -80 mountings 834023 Six-conductor cable (specify length) cable 1