Inductive Conductivity Meter ILM

Similar documents
Inductive Conductivity Meter ILM

Four-beam turbidity measurement ITM-4DW

Inductive Conductivity Meter ILM-4 / ILM-4R

External level devices for conductive point level switch

Instruction Manual. "ILM-4" Inductive Conductivity Sensor

Instruction Manual. "ILM-4" Inductive Conductivity Sensor

Relative Turbidity Meter ITM-51 / ITM-51R

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

Temperature measurement TER8 Front-flush and low-invasive resistance thermometers

Operating Manual MPI-300 NCS-M Parameter Tool

Temperature Measurement SITRANS TS300

OPTISWITCH 6600 C Technical Datasheet

Technical Information Liquipoint FTW23

CombiLyz AFI4 / AFI5 Inductive conductivity transmitter

Universal digital indicator 4½-digit

Inductive sensor NI3-EG08K-Y1-H1341

CombiLyz AFI4 / AFI5 Inductive conductivity transmitter

KROHNE 12/ GR Installation and Operating Instructions BM 500

Technical Information Liquipoint FTW33

LS 6600 Technical Datasheet

Level measurement CleverLevel LBFH Point level detection

Level measurement CleverLevel LBFI Point level detection

Inductive sensor with analog output BI15-M30-LI-EXI

Temperature Switches

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive sensor BI1.5-EG08-Y1-H1341

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

LS 5000 series Vibration Level Switch for liquids

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

C-Flow Coriolis Mass Flow Meter

Flow measurement FlexFlow PF20S Flow sensor for industrial applications

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Level measurement CleverLevel LBFI Point level detection

Adapter system for measuring instruments with G1 hygienic connection Model process adapter

English. Operating Manual. Conductive point level switch MLR120. Retain for later reference. Companies / brands of GHM

Pneumatic Control/Feedback

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Absolute Encoders Multiturn

accurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service

InCos-P Pressure sensor 20 Pa Pa

Operating manual GTL 142 GTL 152. Temperature probe. Please keep the manual for future use.

Operating manual LRD 325. Conductivity measuring cell to be installed in pipelines

Digital electropneumatic Positioner for the integrated mounting on process control valves

Insertion RTD temperature probe

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

Electronic pressure switch with display For sanitary applications Model PSA-31

Pneumatic Control/Feedback

Inductive sensor For rotary actuators NI4-DSU35-2Y1X2-H1140

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

CombiTemp Temperature Measuring System

Magnetic field sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X-H1341

EE771 Series. Flowmeter for compressed air and gases in Industrial Applications. EE771 Compact. EE771 remote probe

Temperature probes 468 Hans Turck GmbH & Co. KG Tel Fax Edition I/

Immersion Temperature Sensors

Absolute Encoders Multiturn

FlexBar HRT Pressure Transmitter

CONDUCELL 4USF ARC SENSORS. Operating Instructions

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Level Transmitter. Table of dimensions see page 4. Total length B Installation length A SW55 Ø 55 Ø 75

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-M12E-Y1X-H1141

Electronic pressure switch with display For sanitary applications Model PSA-31

Rotary Measuring Technology Absolute encoders, Multiturn, DeviceNet

Pneumatic Control/Feedback

Inductive sensor BI5-EM18-Y1X-H1141

GRUNDFOS ALLDOS DATA BOOKLET. Conex DIS-C. Measuring amplifiers and controllers for conductivity measurement 50/60 Hz

TMT470L Temperature Transmitter

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

InBin-P Pressure switches from 5 Pa Pa

Flow Sensor SONOFLOW CO.55

Conductivity-Panelmeter LF 9648 Conductivity measurement with 2-and 4-electrode cells

21D Allfluid pressure switch, electromechanically actuated

The Art of Measuring. Compact Transmitter with Modbus Interface. MemoRail Modbus

Magnetic Field Sensor Magnetic-inductive Proximity Sensor BIM-EG08-Y1X

Rotary Measurement Technology Absolute Encoders, Singleturn

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

OPTIFLUX 6000 Handbook

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Pressure transmitter/pressure switch PASCAL CS

Digital O.R.P. Transmitter Type 8206

Control Head for the integrated mounting on process valves

Installation Instructions Temperature transmitter TAA /00 06/2011

Pressure transmitter/pressure switch PASCAL CS

Level sensor Stainless steel version Model RLT-1000, for industrial applications

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

Operating Instruction

RoHS. High shaft load capacity. Shock / vibration resistant

Operating Manual LF1-LF4 i

ENCODER. Profibus Multiturn. Series , Key-Features:

Rotary Position Technology Absolute Encoders, Singleturn

ExCos-P Pressure sensor 20 Pa Pa

Englisch. Operating Manual. Capacitive Level Sensor MLC490/491/492. Retain for future reference. V3.01. Company / GHM brands

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Level sensor Magnetostrictive, high-resolution measuring principle Models FFG-P, FFG-T, FFG-TP, FLM-H

Process Analysis Systems. Stratos Pro A4 MSPH/MSPH. Chem Energy Pharm Food Water. Connection

Transcription:

SENSORS FOR FOOD AND BIOPHARMA. Product Information ILM-4 FOOD Inductive Conductivity Meter ILM Application/Specified Usage Inductive measurement of the specific conductivity of liquid media in the range of 0...999 ms/cm. Designed for hygienic applications in food-, beverage- and pharmaceutical industries. Authorizations 74-06 Application Examples Controlling of CIP processes (e. g. phase separation detergents/water) Concentration measurement (e.g. Alkali and acid concentration in remaking) Monitoring of product quality, quality control ILM-4 / L20 Hygienic Design/Process Connection Use of Negele CLEANadapt build-in system results in a hygienic installation situation that is free of gaps and dead space and is easy to sterilize. Process connection G1" hygienic or Tri-Clamp, adapters available for milk pipe (DIN 11851), Varivent, DRD (see CLEANadapt product information) CIP/SIP cleaning up to 150 C/maximum 60 minutes All parts with product contact are FDA-compliant Sensor made entirely of stainless steel, submersible body made of PEEK Conformity with 3-A standard Features/Advantages Wear-free, inductive measurement In contrast to conductive measurement procedures, no problems with electrode deterioration or polarization. Accurate measurement through compensation of temperature influences. High reproducibility of 1% of measurement value. Analog outputs for conductivity and temperature are a standard feature. Analog outputs for conductivity, temperature or concentration are freely adjustable. Rapid temperature response time T 90 15...60 s Installation in tube diameters from DN 40 ILM-4 / L50 with Tri-Clamp Options/Accessories Electrical connection via M12 plug-in connector Version with longer toroid housing for pipes DN 65 or for installation into T-fitting Preassembled cable for M12 plug-in connector

FOOD Specification Functional Principle 2 Specification Process connection Thread G1" Tri-Clamp Varivent Materials Temperature ranges Operating pressure Protection class Connecting head Threaded connector Immersible body Plastic cap/sight glass Ambient Process CIP/SIP cleaning CLEANadapt G1" hygienic 1½", 2", 2½", 3" DN 25 (type F), DN 40/50 (type N) Stainless steel 1.4308 Stainless steel 1.4305, 36 mm PEEK, FDA number (21CFR177.2415) Polycarbonate -10...+70 C -10...+130 C Up to 150 C max. 60 min Max. 16 bar IP 69 K (with PG fitting only with use of suitable cable) Reproducibility of conductivity 1% of measurement value Resolution Accuracy Long-term stability Accuracy of temperature output Electrical connection Measurement range < 10 ms/cm 10...100 ms/cm 100...999 ms/cm Slope Offset 100 C 100...150 C Cable gland Cable connection Power supply 1 µs/cm 10 µs/cm 100 µs/cm ±2% of measurement value ±20 µs/cm ±0.5% of upper range limit Max. 0.5 C Max. 1.0 C 2 x M16 x 1.5 2 x M12 connector 1.4305 18...36 V DC max. 190 ma Inputs Range switching Input E1 (24 V DC), galvanically isolated Outputs 2 outputs, free configurable Analog 4...20 ma, short-circuit proof LCD display Backlit display 5 lines Measuring principle Wear-free Inductive Measuring Principle of the Inductive Conductivity Meter An alternating current generates a magnetic field in the primary coil (sender) which induces a current in the circumfluent medium. The current flow in the medium generates another magnetic field in the secondary coil (receiver). The strength of the induced current in the secondary coil depends on the conductivity of the medium. The conductivity of the liquid medium is temperature dependent. To compensate the temperature error, an additional sensor (Pt1000) in the sensor tip is used for monitoring the temperature of the medium. The temperature coefficient (TC-value) of the liquid can be set up in the electronics of the ILM which is used for automatic compensation of the temperature error. Inductive Conductivity Measurement Sender Induced current flow I~ Receiver Pt1000 Medium

3 Dimensional Drawings Installation Instructions FOOD G1" horizontal dimensional drawing G1" vertical dimensional drawing Tri-Clamp dimensional drawing 64 64 SW36 L 64 81 SW36 G 1" 69 73 G 1" SW36 L L 81 73 25 25 25 A Submersion length Tri-Clamp size Type L Type Ø A ILM-4 / L20 20 mm TC1 50.5 mm ILM-4 / L50 50 mm TC2 64 mm T25 77.5 mm TC3 91 mm Mechanical Connection / Installation The sensor has to be installed in that way that the bobbin case is entirely washed around by media and no bubbles can occure. Installation in a rising pipe is recommended. The inscription FLOW on the bottom side of the sensor has to show in flow direction of the medium. Very heavy vibrations can cause measurement errors (e. g. installation very near a pump). Use Negele CLEANadapt system for safe operation of measuring point! Attention: The maximum tightening torque for mounting is 20 Nm! Use a welding mandril for correct installation of CLEANadapt weld-in fittings. Please pay attention to the weld-in and installation details in the CLEANadapt product information. Conditions for a measuring point according to 3-A Sanitary Standard 74-06 The ILM-4 is 3-A compliant. The sensors are designed for CIP/SIP cleaning. Maximum temperature of 150 C for 60 minutes. Only permitted with the CLEANadapt build-in system (EMZ-351, EMK-351, EHG..., adapter AMC-351 and AMV-351). When using the EMZ and EMK weld-in sleeves, the weld must comply with the requirements of the current 3-A Sanitary Standard. Mounting position: The mounting position, self-draining properties and position of the leakage hole must be in accordance with the current 3-A Sanitary Standard.

FOOD Electrical Connection Configuration 4 Electrical Connection - - 1: Power supply +24 V DC 2: Power supply - 3: Digital input E1 4: Output 1 + 5: Output 1-6: Output 2 + 7: Output 2 - + - AE SPS/PLC Parameterization The ILM-4 conductivity sensor is set to operate without requiring special settings. Should the parameters need to be changed, this can be performed using the PC-based MPI-200 programming adapter or the Simple User Interface. The following parameters can be changed directly on-site in the Justage mode or using a dry simulation in the office. Display: Language and contrast of operating panel Conductivity measurement: Conductivity 1: Temperature compensation 1 and upper range limit 1 Concentration: Temperature compensation C, medium concentration range and upper range limit C Conductivity 2: Temperature compensation 2 and upper range limit 2 Settings using the MPI-200 programming adapter The MPI-200 programming adapter is connected to the ILM-4 conductivity sensor via the external MPI-200-F adapter piece. It must be ensured that the ILM-4 conductivity sensor is permanently connected to the supply voltage while the parameters are being set. With M12 plug M12 connector, top (4-pin) 1: Output 1 + 2: Output 2 + 3: Output 2-4: Output 1 - Programming adapter MPI-200-F connection Connection plug for MPI-200-F adapter as an intermediate plug between the ILM-4 electronics and the MPI-200 connection 3 (see next figure). M12 connector, bottom (5-pin) 1: Power supply +24 V DC 2: Not assigned 3: Not assigned 4: Power supply - 5: Digital input E1 M12 connector assignment The M12 standard assignment is compatible with the predecessor model ILM-2. Connection of programming adapter MPI-200 1: Connection for M12 connector 2: USB port for connecting to a PC 3: Connection cable to adapter for ILM-4 1 2 3

5 Operation FOOD Creating settings with the Simple User Interface The software structure of the Simple User Interface is similar to that of the PC version. The system is operated using two control buttons to the left and right of the display. These buttons can be used to navigate to the required parameter. The button functions are as follows: Button Press briefly Press and hold R (right) Jump to next node, parameter Edit a node, parameter L (left) R/L R and L simultaneously Jump back to previous node, parameter Scroll up and down Leave editing mode without saving, return to next higher level Press both buttons for 10 seconds: the menu jumps back to the beginning (attention: this is not a reset) The parameters can be changed by clicking through the menu or using an ID code. To use the ID code, press and hold the right button next to the sensor prompt ID-Search No. The sensor opens the ID-Search page on which the necessary ID code can be entered directly. In the Adjust menu, the following parameters can be set using the ID code: Parameter/parameter name Access/setup mode (must be set prior to change) Search Number (ID Nummer) Node/module Value name Display Language 1 Adjust 451010 4 Display (#) Contrast User Interface 1 Adjust 451020 4 Display (#) Conductivity Measurement Conductivity 1: Temp. Comp. 1 1 Adjust 013031 0 Measure Conducty 1 Upper Range Value 1 1 Adjust 013091 0 Measure Conducty 1 Conductivity 2: Temp. Comp. 2 1 Adjust 013033 0 Measure Conducty 2 Upper Range Value 2 1 Adjust 013093 0 Measure Conducty 2 Concentration C: Temp. Compensation C 1 Adjust 013032 0 Measure Concentr C Media Concentr. Range 1 Adjust 013061 0 Measure Concentr C Upper Range Value C 1 Adjust 013092 0 Measure Concentr C Advice Occuring several media with very different conductivity in the application (e. g. CIP cleaning) switching to an adequate measuring range is neccessary for a precise measurement! Detecting the Temperature Coefficient of the Medium Default setting: TC = 2 %/K 1. Set TC to 0 %/K. 2. Submerge the device in 25 C medium. 3. Wait until the measurement value stops changing. 4. Read off the conductivity from the display and note down the value. 5. Heat the medium to at least 60 C. The conductivity value changes in the display. 6. Wait until the measurement value stops changing. 7. Select the Temp. Komp. parameter and set the determined TC value.

FOOD Warnings Accessories 6 Cleaning/Maintenance When using a pressure washer, do not point the nozzle directly at the electrical connections. Notice on conformity Applicable directives: Electromagnetic Compatibility Directive 2004/108/EC The CE label confirms compliance of this product with the applicable EC directives. You have to guarantee the compliance of all guidelines applicable for the entire equipement. Disposal Transport/Storage No outdoor storage Store in an area that is dry and dust-free Do not expose to corrosive media Protect against solar radiation Avoid mechanical shock and vibration Storage temperature 0...40 C Relative humidity max. 80% Reshipment Sensors and process connection must be clean and must not be contaminated with hazardous media and/or heatconductive paste. Note the cleaning information! To avoid damage of the equipment, use suitable transport packaging only. This instrument is not subject to the WEEE directive 2002/96/EC and the respective national laws. Give the instrument directly to a specialized recycling company and do not use the municipal collecting points. Accessories PVC-cable with M12-connection PVC-cable with M12-connection, 1.4305 (303), IP 69 K, unshielded M12-PVC / 4-5 m PVC-cable 4-pin, length 5 m M12-PVC / 4-10 m PVC-cable 4-pin, length 10 m M12-PVC / 4-25 m PVC-cable 4-pin, length 25 m M12-PVC / 5-5 m M12-PVC / 5-10 m M12-PVC / 5-25 m PVC-cable 5-pin, length 5 m PVC-cable 5-pin, length 10 m PVC-cable 5-pin, length 25 m PVC-cable with M12-connection, brass nickel-plated, IP 67, shielded M12-PVC / 4G-5 m PVC-cable 4-pin, length 5 m M12-PVC / 4G-10 m PVC-cable 4-pin, length 10 m M12-PVC / 4G-25 m PVC-cable 4-pin, length 25 m M12-PVC / 5G-5 m M12-PVC / 5G-10 m M12-PVC / 5G-25 m PVC-cable 5-pin, length 5 m PVC-cable 5-pin, length 10 m PVC-cable 5-pin, length 25 m M12 plug-in screw cap M12-EVK M12 plug-in screw cap, 1.4305 (303), with o-ring, as a protection against humidity and dirt CERT / 2.2 CAL / ILM factory certificate 2.2 acc. to EN10204 (only product contacting surface) factory calibration certificate for ILM

7 Process Connections FOOD Overview of further possible process connections (adapter must be ordered separately!) The complete overview of all available adapters you will find at product information CLEANadapt. ILM-4 Process connection Build-in system EHG (DIN 11850 series 2) Negele weld-in sleeve Negele weld-in sleeve Negele weld-in sleeve Tri-Clamp DN40 EHG-DIN2-40/1" AMC-352/1"-1.5" DN50 EHG-DIN2-50/1" EMZ-352 EMZ-351 EMS-352 AMC-352/2" DN65 EHG-DIN2-65/1" suitable for suitable for pipes suitable for AMC-352/3" DN80 EHG-DIN2-80/1" installation in and vessels with installation in vessels leackage hole pulled-out pipes AMC-352/80 DN100 EHG-DIN2-100/1" AMC-352/100 Overview of further possible process connections (adapter must be ordered separately!) ILM-4 Process connection Dairy flange (DIN 11851) Varivent APV-Inline DN40 AMK-352/40 AMV-352 AMA-352 DN50 AMK-352/50 AMV-352 AMA-352 DN65 AMK-352/65 AMV-352 AMA-352 DN80 AMK-352/80 AMV-352 AMA-352 DN100 AMK-352/100 - AMA-352 Adapter G1½" to G1" AMG-352 suitable for existing G1½" connection Dummy flange BST-350 to close existing measurement points

FOOD Product Information ILM-4 8 Order code ILM-4 (inductive conductivity sensor) Submersion length L20 (20 mm) L50 (50 mm) Process connection (other process connections on request) S01 (standard, CLEANadapt G1" hygienic) TC1 (Tri-Clamp 1½") TC2 (Tri-Clamp 2") T25 (Tri-Clamp 2½") TC3 (Tri-Clamp 3") V25 (Varivent type F, DN 25) V40 (Varivent type N, DN 40/50) Head orientation H (horizontal head orientation) V (vertical head orientation) Output A42 A62 A63 (1x 4...20 ma conductivity value only, display prepared) (2x 4...20 ma conductivity/temperature selectable, no external range switching, display prepared) (2x 4...20 ma conductivity/temperature selectable, external range switching, display prepared) Electrical connection P (cable gland M16x1.5) D (2x cable gland M16x1.5) M (1x M12 connector, 5-pin) N (2x M12 connector, standard) A (2x M12 connector, 4-pin, power supply/output, 5-pin output/input) Interface/Display X (without Interface) S (Simple User Interface with small Display) Enclosure X (plastic cap without sight glass) P (plastic cap with sight glass) M (stainless steel cap without sight glass) W (stainless steel cap with sight glass) Parameter configuration X (standard) S (write out details) ILM-4 / L20 / S01 / V / A63 / D / S / P / X 50088 / 1.0 / 2016-04-27 / TB / EU NEGELE MESSTECHNIK GMBH Raiffeisenweg 7 87743 Egg an der Guenz Phone +49 (0) 83 33. 92 04-0 Fax +49 (0) 83 33. 92 04-49 sales@anderson-negele.com Tech. Support: support@anderson-negele.com Phone +49 (0) 83 33. 92 04-720