Quick Reference Datasheet For All RIT113 Packages For Rotational Therapies, IMRT & TG142 Highlights and selected product information only. A complete TG142 brochure is available. For more information on this, other analysis routines, and image capture options visit radimage.com or call 719.590.1077., is our original version. It includes all the patient and machine QA routines that we have developed to help the medical physicist perform all the analysis requirements they may ever need to perform. RITG142, is just what you need, to meet all and only those tests recommended in TG142. RIT Complete is a combination of RIT113 Classic, and Radia Therapy in one convenient package. Cut Out The Middle Machine Use Your EPID For QA
Recently Added Some analysis routines, functions and features recently added to RIT113 - for more details on each, visit radimage.com Packages Performs or trends EVERY test in TG142. See our TG142 Datasheet for complete information and package options. Statistical Trend Database RITtrend is much more than a statistical database. You easily set your own specifications and then automatically analyze process control limits on RIT113 analyzed equipment, knowing when and where to make changes in your system to reduce its overall variability. The new Multi Source Data Manager gives you even more control for reporting on your entire Medical Physics program. It s customizable format allows you to add analysis data from any and all equipment used in your Medical Physics program, including non RIT113 analyzed data. It redefines database recording into a major tool for analysis and recordkeeping in your department. Static and Dynamic MLC Elekta Jaw Setback Test Elekta Leaf Position Test Improved Picket Fence Tests Image Capture Image Compositor Great new GUI interface for easily making composite images. Add together images for use in MLC QA, Stereotactic QA, and large field IMRT analysis. Primarily used for EPID images but can be used on all image types. This routine also supports a number of other operations: Add, subtract, multiply, divide, and other operations including scaling. EPID Importing EPID Images for QA Use your Elekta, Varian or Siemens EPID for QA with a seamless interface that does not require additional manufacturer hardware and software. Quickly and easily composite EPID images into RIT format using the new Image Compositor. EPID Calibration RIT s patented Plan Based Calibration routine gives you the ability to make quick relative comparisons between any dose map and your EPID, FILM or CR. Elekta iview Calibration Varian as Calibration Scale DICOM images from Varian EPIDs Some Varian EPID images may contain scaling information to restore dose information. If this featured is enabled (in preferences) the Varian as Portal Image Interface will detect these parameters and restore the EPID image. An optional scaling factor may also be applied. 2
2D Detector Arrays Import From 2D Arrays Ion Chamber arrays from IBA and PTW and MapCheck diode arrays are supported. IMRT analysis routines have been revised to handle sparse data. Results can be saved as an RIT Array Case file. PTW seven29 Direct Interface This interface operates similarly to our direct interface to your film scanner. It simplifies temperature and pressure value entry, making them very quick and easy. Then, the image is automatically imported into RIT113 for analysis. Film Dosimetry for QA Radiochromic and Radiographic Film with Vidar and Flatbed Scanners EBT2 and Flatbed Scanner Correction Corrects EBT film scanned on a flatbed scanner for: Red/Blue channel correction AND scanner flatness and uniformity. A dose calibration file is also created all from one image set. Utilizes RIT s patented Plan Based Calibration to develop optimized calibration curves. (Available for international customers only. Not available in the USA.) Radiochromic Film Uniformity Correction Automated 21 Point Film Processor Correction Sensitometry 2D Scanner Spatial Calibration (Vidar and Flatbed Scanners) Direct interface with all Vidar Dosimetry scanners Generic Image File Import Importing generic JPEG, TIFF and Bitmap image files from sources other than your Vidar Scanner gives you increased flexibility in your workflow to use RIT s exclusive analysis routines. Perfect for Cyperknife analysis! Vidar Advantage Pro 180 Correction For use on Advantage Pro RED units only: Corrects for sloping profile from left side to center; Works with film up to 10 wide and Improves flatness by a factor of 2 to 4. Improved Vidar Scanner Interface (Vidar Scanner Control Center) Allows for multiple film scanning, auto-naming, and autocropping, auto-flipping, and preview of scanned images CR 3D CR Flatness & Uniformity Correction Kodak CR Perpendicular Calibration Kodak CR Spatial Calibration 3D Gels and Solids Are Supported 3
Automated Batch Analysis Fully automated registration control point positioning in both traditional and RunQueueA IMRT analysis. Automated matching and sorting of reference and target images along with thumbnail of all images simultaneously Extended options for output storage to reference or target image file path ROI Trim Option RITtrend TM Statistical Trend Database RITtrend is much more than a statistical database. You easily set your own specifications and then automatically analyze process control limits on RIT113 analyzed equipment, knowing when and where to make changes in your system to reduce its overall variability. The new Multi Source Data Manager gives you even more control for reporting on your entire Medical Physics program. It s customizable format allows you to add analysis data from any and all equipment used in your Medical Physics program, including non RIT113 analyzed data. It redefines database recording into a major tool for analysis and recordkeeping in your department. IMRT, IGRT & RapidArc/VMAT Analysis Gamma Function Using the Classical Gamma Analysis method by Low, et. al. Using the new Digital Gamma Plot in the IMRT measurements menus, this algorithm is based on A quantitative evaluation of IMRT dose distributions: refinement and clinical assessment of the gamma evaluation, Dupuydt et al., Radiotherapy and Oncology 62 (2002) 309 319. Using the optional algorithm accessible in the preference settings of RIT, this algorithm is proposed in Geometric interpretation of the dose distribution comparison technique: Interpolation-free calculation, Ju et al., Medical Physics, Vol. 35, No. 3, March 2008. Distance To Agreement Water Tank Beam Measurement Analysis Profiles Van Dyk's Analysis Subtraction Composite Analysis Isodose Curves Addition IGRT Alignment Used to measure the spatial misalignment between the IGRT imaging system and the treatment beam Register Template IMRT Automatic Fine Tune Registration 4
3D QA Phantom Bilinear Interpolation & Non-cropping Rotation Import from 2D Detector Arrays Ion Chamber arrays from IBA and PTW and MapCheck diode arrays are supported. IMRT analysis routines have been revised to handle sparse data. Results can be saved to a RIT Array Case file. Automated Registration Fully automated registration control point positioning in both traditional and RunQueueA IMRT sumultaneously. Brainlab Flip images as they are imported Automated matching of Images RunQueueA features automated matching and sorting of reference and target images along with thumbnails of all images simultaneously. Improved initial positioning of acquired image points when using template registration. Extended options for output storage location in RunQueueA scripts to either the reference or target image file path. New ROI option trim in RunQueueA Allows the user to specify a trim dimension from each edge of the images New IMRT analysis plot called Proportion Passing Plots the proportion passing for a range of subtraction tolerances Case files can be saved from IMRT analysis toolbars. It is not necessary to use RunQueueA to make a Case file. Send IMRT results to other RIT users or Tech Support. Save and Restore all IMRT Analysis Layouts Use arrow keys to move Profiles in IMRT and other beam measurements. Auto-increment registration points to eliminate registration errors. Improved Normalization Improved Fine Tune Registration TomoTherapy Beam Planarity and Jaw Twist Overhead Laser Import Calibration files Import Tomo "DICOM" files 5
Static and Dynamic MLC Generic Picket Fence Generic picket fence images may have any number of pickets and at any spacing as long as they are regular. Improved MLC analysis (includes Bayouth test) MLC images do not need to be calibrated, may be any size, and will be referenced back to 100 SSD. You will now enter the SSD with each image. Automated Analysis of Varian RapidArc Tests Images may be of any size (from up in the accelerator head to down on the floor). EPID, Film, or CR images may be used and tests and comparison at multiple gantry angles are supported. Bayouth MLC Analysis Memorial Sloan Kettering Test Pattern MLC Transmission Analysis (TG50 Recommended) 50% Fluence Analysis (TG50 Recommended) Improved picket fence tests Elekta Jaw Setback Test Elekta Leaf Position Test Varian DMLC Test Patterns Analysis Ability to import Elekta.HIS files Dose Calibration Daily Output Factor Adjustment Calibration Data Point Highlighter Plan Based Calibration (US Patents 7233688, 7024026, CA Patent 2567197, International Patents Pending) The ability to make quick relative comparisons between any dose map and your Film, Array, and CR images. MLC Calibration Technique (US Patents 6675116, 6934653, International Patents Pending) 2D Scanner Spatial Calibration for both Vidar and Flatbed Scanners Perpendicular Dose Calibration Varian as Calibration iview Calibration Parallel Dose Calibration Kodak CR Perpendicular Calibration Kodak Spatial Calibration PDD Table Editor 6
EBT2 and Flatbed Scanner Correction Plus Calibration Corrects EBT film scanned on a flatbed scanner for Red/Blue channel correction AND scanner flatness and uniformity. A dose calibration file is also created all from one image set. It utilizes RIT s patented Plan Based Calibration to develop optimized calibration curves. (Available for international customers only. Not available in the USA.) Stereotactic Analysis Stereotactic Cone Profiles Stereotactic Alignment Star Shot and Stereotactic images may be analyzed without applying a calibration file. Use EPIDs to acquire Winston Lutz images. Using the RIT Image Compositor they can be analyzed in one test on a composite image. Beam Measurements Cyberknife Alignment Improved alignment routine for low contrast cones. Star Shot Analysis Star Shot and Stereotactic images may be analyzed without applying a calibration file. Performing MLC Starshot test using the RIT Image Compositor to make MLC starshot patterns. Radiation/Light Field Coincidence Radiation/Light Field EPID images may be analyzed without applying a calibration file. You can also have custom field sizes, not just 5, 10, 15, and 20 cm., and take a BB or pin prick for center location. Asymmetric Field/Matchline Depth Dose Cross Sections 3D Dose Profiles Electron Energy Quick Flatness & Symmetry Isodose Contours Cross Profiles Enhancements Indicator lines added to profile plots to indicate location of opposite profile; Ability to lock the intersection; Moveable profile bar; FWHM measurements reported for each side of the profile. Useful for MLC tests on jaw positions on Elekta machines and for Gamma Knife commissioning. Monitor Calibration with TG18 and SMPTE Brainlab Flip images as they are imported 7
Therapy Routines Included in RIT113 Complete and Radia Base plus KV Imager routines DISC Plus IBA Primus L PTW Normi-4 Leeds TOR 18FG ISO Cube Radia Base plus MV Imager routines PTW Las Vegas QC-3 Siemens ISO Cube Radia Base plus CBCT Imager Catphan Elekta XVI ISO Cube Radia Base plus Electron Density (optional add-in) 062 062A Gammex Cheese Visit www.radimage.com Call 719-590-1077 Email sales@radimage.com Radiological Imaging Technology, Inc., July, 2012 8