Integrated Power and Automation

Similar documents
PowerMonitor 1000 Unit Catalog Number Upgrade

Rockwell Automation Library of Steam Table Instructions

Reference Manual. Rockwell Automation Library of Process Objects: Condition Gate Delay (P_Gate) Version 3.5

IntelliCENTER IEC Integration Unit

Disconnect Switch and Circuit Breaker Mechanism Specifications Bulletin Number 1494

PowerMonitor 5000 Unit Catalog Number Upgrade

InView Communication Modules

Reference Manual. Rockwell Automation Sequencer Object Version 4.0

ControlLogix Redundancy Update and Module Replacement Guidelines

Logix5000 Controllers Nonvolatile Memory Card

PowerMonitor 5000 USB Driver

Studio 5000 Architect Getting Results Guide

Catalog Numbers 9308-RSFB64ENE, 9308-RSFB256ENE, 9308-RSFB1024ENE

PCI Expansion Slot Kit for 6181P (1500P) Series D Integrated Display Computer

GuardLogix: Dual Zone Gate Protection with E-stop and Trojan Interlock Switch

SequenceManager Controls

GuardLogix: Safety Gate Application with SensaGuard Switch

Quick Start. PlantPAx System Application Templates System Release 3.0

FLEX 5000 Digital I/O Modules

T48 - Integrating Your Power and Automation Control Systems

CENTERLINE 2100 Motor Control Centers EtherNet/IP Network Adapter

GuardLogix: TLS Guardlocking Application

Allen-Bradley Replacements

Application Technique. Products: Guardmaster 440C-CR30 Configurable Safety Relay, PowerFlex 755 Drive. Safety Rating: CAT. 3, PLe to ISO : 2008

Logix5000 Control Systems: Connect a PanelView Plus Terminal over an EtherNet/IP Network

Logix5000 Controllers Produced and Consumed Tags

ProcessLogix R510.0 Server Installation Instructions

ControlLogix SIL2 System Configuration

Starter and Circuit Breaker Application with PowerFlex 7000

POINT I/O and ArmorPOINT I/O EtherNet/IP Adapters

Logix5000 Controllers Produced and Consumed Tags

CompactLogix Power Supplies Specifications

ControlLogix Redundancy

Teaching Color-Sensing Connected Components Building Block. Quick Start

Reference Manual. Embedded Switch Technology Reference Architectures

PowerFlex 755 Common DC Input Drives, Frames Interlock Assembly and Precharge Assembly Left-front Cover Retrofit Kit

PHOTOSWITCH Distance Measurement Sensor

Kinetix 6000 Axis Module and Shunt Module

Quick Start. Logix5000 Control Systems: Connect Kinetix 350 Drives over an EtherNet/IP Network

ControlLogix Redundancy

PowerFlex 70 Safe-Off Control EtherNet/IP Guard I/O Safety Module and GuardLogix Integrated Safety Controller

GuardLogix 5570 Controller Systems

InView Firmware Update

Cisco & Rockwell Automation Alliance. Mr. Gary Bundoc Solutions Architect Rockwell Automation Phil Inc.

DeviceNet Network Configuration

Actuator Subsystems Stop Cat. 0 or 1 via an Integrated Safety Controller and PowerFlex 527 Drive with Hardwired Safe Torque Off Safety Function

GuardLogix Controller Systems

Solar Combiner Enclosure

1756 ControlLogix Chassis Specifications

PlantPAx Distributed Control System

GuardLogix Controller to Kinetix 6000 Drive with Safe-Off using EtherNet/IP CompactBlock Guard I/O Module

Product Compatibility and Download Center

Color-Sensing Connected Components Building Block. Quick Start

ControlLogix HART Analog I/O Modules

Product Compatibility and Download Center

Allen-Bradley Motors

MicroLogix 1400 Embedded Web Server

ControlLogix Digital I/O Modules

Logix5000 Controllers Messages

Using a Guard Locking Interlock Switch and Light Curtains with DeviceNet Guard I/O and a GuardLogix Controller

PanelView Plus 7 Standard Terminals

GuardLogix Controller Systems

USB-to-DeviceNet Cable

Simple Package Measurement Connected Components Building Block. Quick Start

Kinetix 5700 Safe Monitor Functions

Adapter Kit for PanelView 1200/1200e Touch Screen Terminal Cutout

Point Guard I/O Safety Modules

Installation Instructions. FactoryTalk View Site Edition Installation Guide

Stratix Industrial Ethernet Switch. Features and Benefits

NHP SAFETY REFERENCE GUIDE

Digital ac/dc (24V) Input Module

T02 - Design Considerations for Robust EtherNet/IP Networking

Using TLS3-GD2 Guardlocking Interlock with ArmorBlock Guard I/O and SmartGuard Controller

Applying EtherNet/IP in Real-time Manufacturing. Copyright 2012 Rockwell Automation, Inc. All rights reserved.

Sizing PlantPAx System Architecture for Optimal Performance. For Classroom Use Only!

EtherNet/IP Communication Modules in Logix5000 Control Systems

PanelView 5510 Terminal Specifications

Kinetix 300 Memory Module Programmer

Installation Instructions

FactoryTalk View Site Edition. Installation Guide

DeviceNet Communications

POINT I/O and ArmorPOINT I/O Dual Port EtherNet/IP Adapters

User Manual. PowerFlex ENETR Dual-port EtherNet/IP Option Module Firmware Revision Number 1.xxx

Scalability-The Best Approach to Change

Allen-Bradley to-230V Conversion Kit Cat. Nos FC FC075

Distributed Control System Training Curriculum. PlantPAx. Distributed Control System. Improve Performance with a Complete Workforce Training Solution

Installation Instructions

W05 High Availability for Today s Process Market

Application Technique. Products: Guardmaster 440C-CR30 Configurable Safety Relay, PowerFlex 525 AC Drive

Electronic Keying in Logix5000 Control Systems

Logix5000 Control Systems: Connect POINT I/O Modules over a DeviceNet Network

Guard I/O EtherNet/IP Safety Modules

L01 - Basic Stratix Switch and EtherNet/IP Features in Converged Plantwide Ethernet (CPwE) Architectures

PanelView Plus to PanelView Plus 6 Catalog Number Conversions

Using GuardShield Light Curtains (Safe 4, Micro 400, or 440L), with ArmorBlock Guard I/O and SmartGuard Controller

Fork Sensors. Technical Data. Plastic Fork Sensors

Getting Results Guide. RSLinx Enterprise

Logix5000 Controllers Function Block Diagram

ControlLogix 5580 and GuardLogix 5580 Controllers

L01 - Effective Design Methods for Integrating Safety Using Logix Controllers. For Classroom Use Only!

Transcription:

Reference Manual Original Instructions Integrated Power and Automation Catalog Numbers 3300A-IU10J-A1-1, 3300A-IU10J-A1-1-PVP, 3300A-IU10J-A1-1-SSA, 3300A-IU10J-A1-1-PVP-SSA, 3300A-IU10J-A1-2, 3300A-IU10J-A1-2-PVP, 3300A-IU10J-A1-2-SSA, 3300A-IU10J-A1-2-PVP-SSA, 3300A-IU10J-A1-3, 3300A-IU10J-A1-3-PVP, 3300A-IU10J-A1-3-SSA, 3300A-IU10J-A1-3-PVP-SSA, 3300A-IU10J-A1-4, 3300A-IU10J-A1-4- PVP, 3300A-IU10J-A1-4-SSA, 3300A-IU10J-A1-4-PVP-SSA, 3300A-IU10J-B1-1, 3300A-IU10J-B1-1-PVP, 3300A-IU10J-B1-1-SSA, 3300A-IU10J-B1-1-PVP-SSA, 3300A-IU10J-B1-2, 3300A-IU10J-B1-2-PVP, 3300A-IU10J-B1-2-SSA, 3300A-IU10J- B1-2-PVP-SSA, 3300A-IU10J-B1-3, 3300A-IU10J-B1-3-PVP, 3300A-IU10J-B1-3-SSA, 3300A-IU10J-B1-3-PVP-SSA, 3300A- IU10J-B1-4, 3300A-IU10J-B1-4-PVP, 3300A-IU10J-B1-4-SSA, 3300A-IU10J-B1-4-PVP-SSA

Important User Information Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards. Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably trained personnel in accordance with applicable code of practice. If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment. The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual. Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited Throughout this manual, when necessary, we use notes to make you aware of safety considerations. WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss. ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequence. IMPORTANT Identifies information that is critical for successful application and understanding of the product. Labels may also be on or inside the equipment to provide specific precautions. SHOCK HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that dangerous voltage may be present. BURN HAZARD: Labels may be on or inside the equipment, for example, a drive or motor, to alert people that surfaces may reach dangerous temperatures. ARC FLASH HAZARD: Labels may be on or inside the equipment, for example, a motor control center, to alert people to potential Arc Flash. Arc Flash will cause severe injury or death. Wear proper Personal Protective Equipment (PPE). Follow ALL Regulatory requirements for safe work practices and for Personal Protective Equipment (PPE).

Table of Contents Preface........................................................5 About This Publication......................................... 5 Terminology................................................... 5 Additional Resources........................................... 6 Introduction to Integrated Power and Automation Components and Core Elements of IPA Connecting IntelliCENTER IEC 61850 Integration Unit Into the Plant Network Chapter 1 Rockwell Automation Integrated Power and Automation......... 7 A Unified Architecture with the IntelliCENTER IEC 61850 Integration Unit............................................... 8 Chapter 2 Logix Controller............................................... 9 Stratix 5700 Managed Switch.................................. 10 ProSoft Gateway.............................................. 10 Stratix 5950 Security Appliance................................ 10 PanelView Plus 7.............................................. 11 Chapter 3 Connecting IntelliCENTER IEC 61850 Integration Unit to Electrical Protection Devices................................. 13 IEC-61850 Specifics....................................... 14 VLAN Segmentation...................................... 14 Testing, Sizing, and Characterization Guidelines for the IntelliCENTER IEC 61850 Integration Unit................... 15 Sample System............................................ 15 Test Configuration........................................ 16 Configuration Overview................................... 17 Test Requirements........................................ 19 Evaluation Criteria........................................ 19 Test Results............................................... 19 Converged Plantwide Ethernet (CPwE) Guidelines For Connecting the IntelliCENTER IEC 61850 Integration Unit to PlantPAx Process Automation System.......................... 21 Simplex Integration........................................ 22 Redundant Integration..................................... 23 Index........................................................25 Rockwell Automation Publication 3300A-RM001A-EN-P - October 2017 3

Table of Contents Notes: 4 Rockwell Automation Publication 3300A-RM001A-EN-P - October 2017

Preface About This Publication This manual describes the Allen-Bradley IntelliCENTER IEC 61850 Integration Unit with a focus on the system architecture and integration into your plant. Terminology This table defines abbreviations that are used in this manual. Abbreviation Full Term Definition AOP Add-on Profile Studio 5000 Logix Designer application tool that is used to integrate devices into the programming environment. CID Configured IED Description files An XML file that defines all information that can be communicated from the IED. CIP Common Industrial Protocol Industrial protocol for industrial automation applications that ODVA supports. CPwE Converged Plantwide Ethernet A Cisco and Rockwell Automation collaboration to provide recommendations and guidance to help the following: Reduce network latency and jitter Increase the availability, integrity, and confidentiality of data Design and deploy a scalable, robust, secure, and future-ready EtherNet/IP network infrastructure DCS Distributed Control System A specially designed control system for complex and large applications in industrial processes wherein the control elements of the system are distributed geographically throughout the plant. In a DCS, a hierarchy of controllers is connected by communication networks for command and monitoring. GOOSE Generic Object Oriented Substation Event A control strategy to remotely collect and control devices in a distributed system. IED Intelligent Electrical Devices These devices can consist of feeder protection devices, motor protection devices, transformer protection devices, generator protection devices, intelligent circuit breakers, and power monitors. IEEE Institute of Electrical and Electronics Engineers Organization that standardizes electrical engineering practices. IMC Intelligent motor control Motor control devices that can connect to a communication network. IPA Integrated Power and Automation The Rockwell Automation Integrated Power and Automation (IPA) solution combines the communication efforts of EtherNet/IP and IEC 61850 networks into one seamless architecture where intelligent motor control and intelligent electrical control are represented through one control, visualization, and reporting system while operating on separate networks. MCC Motor control center A motor control center is an assembly of one or more enclosed sections having a common power bus and contains motor control units. A motor control center can include variable frequency drives, programmable controllers, and metering units. ODVA Organization that standardizes communication networks that use CIP among other technologies. PAC Programmable Automation Controller Multidiscipline controllers that are used across manufacturing disciplines such as discrete, continuous process, batch, drive, motion, and safety. REP Resilient Ethernet Protocol Redundant network topology protocol/feature in the Stratix 5700 switch. SCADA Supervisory Control and Data Acquisition A control strategy to remotely collect and control devices in a distributed system. VLAN Virtual local area network Tool that is provided in Layer 2 switches that allows similar networked devices to be grouped in a broadcast domain. WAN Wide Area Network This type of network consists of infrastructure in which the network traffic is passed through points that the user does not own and can then be referred to as an untrusted network. Rockwell Automation Publication 3300A-RM001A-EN-P - October 2017 5

Preface Additional Resources These documents contain more information about related products from Rockwell Automation. Resource IntelliCENTER IEC 61850 Integration Unit Installation Instructions, publication 3300A-IN001 IntelliCENTER IEC 61850 Integration Unit Technical Data, publication 3300A-TD001 CompactLogix 5380 Controllers Specifications Technical Data, publication 5069-TD002 1756 ControlLogix and GuardLogix Controllers Technical Data, publication 1756-TD001 Stratix Ethernet Device Specifications Technical Data, publication 1783-TD001 PlantPAx Rockwell Automation Library for Electrical Protection Devices Reference Manual, publication PROCESS-RM011 ProSoft Communication Gateway User Manual CompactLogix 5380 Controllers User Manual, publication 5069-UM001 ControlLogix System User Manual, publication 1756- UM001 Stratix 5700 Industrial Ethernet Switch Product Profile, publication ENET-PP005 Stratix 5700 Ethernet Managed Switches User Manual, publication 1783-UM007 Stratix 5950 Security Appliance User Manual, publication 1783-IN010 PanelView Plus 7 Standard Terminals, publication 2711P- UM007 Converged Plant-wide Ethernet (CPwE) Design and Implementation Guide, publication ENET-TD001 Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1 Product Certifications website, http:// www.rockwellautomation.com/global/certification/ overview.page Description Provides installation instructions for the IntelliCENTER IEC 61850 Integration Unit. Provides specifications and unit selection information for the IntelliCENTER IEC 61850 Integration Unit. Provides specifications, wiring diagrams, and functional block diagrams for CompactLogix 5380 controllers. Provides specifications ControlLogix 5580 controllers. Provides specifications for the Stratix switches. Provides information on how to configure the Add-On Instructions that control and monitor intelligent power devices that use the IEC 61850 standard in the PlantPAx system. Provides information and specifications for the IEC 61850 to Ethernet network gateway. Provides information on how to use CompactLogix 5380 controllers. Provides information on how to use ControlLogix 5580 controllers. Provides Stratix 5700 switch information. Provides Stratix 5700 switch information. Provides a product overview, explains how to connect and configure the security appliance. Provides information to install, configure, operate, and troubleshoot the PanelView Plus 7 Standard terminals. Describes how to design a Converged Plantwide Ethernet network. Provides general guidelines for installing a Rockwell Automation industrial system. Provides declarations of conformity, certificates, and other certification details. You can view or download publications at http://www.rockwellautomation.com/global/literature-library/overview.page. To order paper copies of technical documentation, contact your local Allen-Bradley distributor or Rockwell Automation sales representative. 6 Rockwell Automation Publication 3300A-RM001A-EN-P - October 2017

Chapter 1 Introduction to Integrated Power and Automation Rockwell Automation Integrated Power and Automation Coordination of large distributed measurement and control systems, like SCADA and other process control implementations, requires robust networks that connect thousands of remote devices. Whether it's a new plant or an upgrade, miscommunication between technology vendors and system engineers during design phases can cause future unforeseen integration challenges. With electrical power distribution and automation control systems being traditionally supplied independently, unnecessary complexity and cost throughout the life of the solution can arise. By using the EtherNet/IP protocol, intelligent motor control devices communicate and work as a part of the process control system. Simultaneously, critical substation equipment communicates with intelligent electrical devices (IED) over an unmodified Ethernet network that is based on the IEC 61850 standard. Both of these communication standards are typically kept independent with separate control, visualization, and reporting environments, which duplicates the effort to monitor devices and keep systems operational. The Rockwell Automation Integrated Power and Automation (IPA) solution combines these efforts into one seamless architecture where intelligent motor control and intelligent electrical control are represented through one control, visualization, and reporting system while operating on separate networks. This control is accomplished by bridging a portion of the IEC 61850 traffic into the Studio 5000 Logix Designer environment and representing important data within FactoryTalk software for user consumption. Once established, customers can use the Logix Designer application and FactoryTalk software as their single environment for their system architecture. Some electrical control processes require equipment to be supplied from multiple vendors. Rockwell Automation has partnered with multiple vendors to give customers flexibility and choose the best products to suit their electrical control application needs. Once chosen, Rockwell Automation coordinates the delivery of this equipment in a cost-effective manner, and verifies that the integration of the equipment is seamless on the back end. Rockwell Automation Publication 3300A-RM001A-EN-P - October 2017 7

Chapter 1 Introduction to Integrated Power and Automation A Unified Architecture with the IntelliCENTER IEC 61850 Integration Unit Rockwell Automation has a long history of device connectivity with the Logix Designer application. To deliver a common experience when communicating with devices over the IEC 61850 standard, the IntelliCENTER IEC 61850 Integration Unit was developed. The integration unit contains standard hardware and standard software to bring a portion of the IEC 61850 traffic into the Logix architecture, delivering ease-of-use and seamless integration. Inside the integration unit is all equipment necessary to bridge the IEC 61850 traffic into Logix Designer. This equipment includes a gateway for communication bridging, a Stratix 5700 switch for aggregation of device connections and segmentation, and a ControlLogix or CompactLogix rack. Also, there are options for a PanelView terminal for data representation and a Stratix Security Appliance if unsecured upstream connections are required. Once inside the Logix architecture, the IEDs are monitored within FactoryTalk software with Process Object Library faceplates. By using the integration unit, you can unify power and process systems within the Logix and FactoryTalk environments to create one operating environment. Faceplates for the Allen-Bradley 857 Motor Protection Relay, ABB circuit breakers, and Schweitzer protection relays verify that you can choose the appropriate device that meets the needs of your application. These faceplates look and operate like all other Allen-Bradley intelligent devices, delivering a common user interface for the single monitoring and reporting environment. 8 Rockwell Automation Publication 3300A-RM001A-EN-P - October 2017

Chapter 2 Components and Core Elements of IPA The IntelliCENTER IEC 61850 Integration Unit contains core components that are part of the configured to order product. By leveraging the control capabilities of a Rockwell Automation Logix processor, network management from Stratix managed switches, optional visualization with PanelView Plus 7 terminals, and enhanced security functions with the Stratix 5950 Security Appliance, the integration unit enables the intelligent switchgear and intelligent E-house to become part of the Integrated Architecture system. This system provides ease of integration into the existing network of intelligent motor control devices and lets you take advantage of a unified architecture throughout the facility. The PlantPAx distributed control system is a modern DCS that is not only scalable and flexible, but provides functionality, reliability, and performance consistence with expectations from a traditional DCS. The PlantPAx system is able to integrate control systems that use intelligent motor control and intelligent electrical protection devices. The components within the integration unit are essential to make integration possible into a Logix processor and leverage the benefits of the Integrated Architecture system. Logix Controller When specifying the components inside of the integration unit, there are two options when selecting the programmable controller: CompactLogix 5380 controller - can be used for mid-range applications such as batch processing or machine control when you need a chassis-based, modular design. ControlLogix 5580 controller - offers increased I/O and network options and is designed to work in distributed or supervisory control applications. Both the CompactLogix and ControlLogix programmable controllers can be accessed and programmed by using the Logix Designer application. Rockwell Automation Publication 3300A-RM001A-EN-P - October 2017 9

Chapter 2 Components and Core Elements of IPA Stratix 5700 Managed Switch The Stratix 5700 managed switches are compact and scalable Layer 2 switches with embedded Cisco technology for use in a wide range of applications from small and isolated to large complex networks. The Stratix 5700 managed switch integrates into Studio 5000 applications. Industrial-managed Ethernet switches are designed to give you the flexibility and features that helps prevent lost data due to Layer 2 faults and broadcast traffic, which is critical to network performance. With an industrial managed Ethernet switch, network segmentation, such as Virtual LANs (VLANs), and network resiliency, such as Resilient Ethernet Protocol (REP), can be implemented to make sure that network performance is maintained across a complex industrial Ethernet network. Advanced security, network management, and diagnostics are other critical features that are provided in an industrial managed Ethernet switch. These features make sure that the expected recipient receives the information being sent over the network at the expected time while network issues are allowed to be easily resolved. For more information on the Stratix 5700 switch, see publication 1783- UM007. ProSoft Gateway The ProSoft PLX82-EIP61850 gateway module is used to convert the IEC 61850 traffic to EtherNet/IP traffic, which the Logix controller consumes. This conversion makes it possible for the Logix controller to interface with IEC 61850 intelligent electronic devices such as substation protective relays and power monitoring equipment. Stratix 5950 Security Appliance The Stratix 5950 Security Appliance incorporates several key security functions into one appliance to help protect your industrial automation infrastructure. The Stratix 5950 Security Appliance provides control to network traffic. The typical Wide Area Network (WAN) consists of infrastructure in which the network traffic is passed through points that the user does not own and can then be referred to as an untrusted network. The integration unit can be configured with a Stratix 5950 Security Appliance to interface with the untrusted network. For more information on the Stratix 5950 Security Appliance, see publication 1783-UM010. 10 Rockwell Automation Publication 3300A-RM001A-EN-P - October 2017

Components and Core Elements of IPA Chapter 2 PanelView Plus 7 The optional PanelView Plus 7 terminal is an operator interface device that is used to monitor and control devices that are connected to the CompactLogix or ControlLogix controller over an EtherNet/IP network. The terminal can be used to display information critical to the IED or process, and provide quick diagnostics and ability to configure the system. Rockwell Automation Publication 3300A-RM001A-EN-P - October 2017 11

Chapter 2 Components and Core Elements of IPA Notes: 12 Rockwell Automation Publication 3300A-RM001A-EN-P - October 2017

Chapter 3 Connecting IntelliCENTER IEC 61850 Integration Unit Into the Plant Network Within the Unified Architecture, it is important that a developed network is not only robust for the current needs of operations, but allows the system infrastructure to evolve over time without requiring a substantial overhaul. This chapter focuses on the process and recommended practices for connecting the IntelliCENTER IEC 61850 Integration Unit to the plant-wide network infrastructure. Connecting IntelliCENTER IEC 61850 Integration Unit to Electrical Protection Devices When connecting the integration unit to the IEC 61850 network, it is important to note the number of ProSoft IEC 61850 Gateways that are installed in your particular unit. The number of gateways equals the number of cables that are required to interface the integration unit to the IEC 61850 network of electrical protection devices. For each ProSoft Gateway, there is one network cable that is required to interface to the IEC 61850 network. This network segmentation allows for an evaluation and characterization of network traffic of the gateway module itself. See Testing, Sizing, and Characterization Guidelines for the IntelliCENTER IEC 61850 Integration Unit for more information. Figure 1 shows how the integration unit connects to a system of Intelligent Electrical Devices (IEDs). IntelliCENTER IEC 61850 Integration Unit Figure 1 - System Configuration To Trusted Network ProSoft IEC 61850 to EtherNet/IP Gateway IED IED Stratix 5700 Managed Switch ControlLogix Controller Cisco IE 2000U Managed Switch IED IED Rockwell Automation Publication 3300A-RM001A-EN-P - October 2017 13

Chapter 3 Connecting IntelliCENTER IEC 61850 Integration Unit Into the Plant Network IMPORTANT For each ProSoft module in the integration unit, there is one network connection to the IEC 61850 network. The network infrastructure (provided outside the integration unit) must be selected and sized to handle the IEC 61850 traffic loading. IEC-61850 Specifics The IntelliCENTER IEC 61850 Integration Unit has been tested and characterized for the performance of a 40 IED system in an MMS client configuration. IMPORTANT All testing and validation that is provided in this document was done based on MMS buffered reports and MMS commands. None of the characterization testing that is provided for this document included GOOSE subscriber functionality. When connecting to an IEC 61850 switch, note the following considerations: The switch supports IEEE C37.238 (Power Profile PTP) if time synchronization required. The switch supports a Quality of Service (QoS) specifically for IEDs. VLAN Segmentation The best way to segment IEC 61850 traffic is by using virtual local area networks (VLANs). This methodology lets you configure ports on a managed switch in a logical fashion for traffic management. For example, IEC 61850 traffic is subjected to ports where IEDs are connected, while HMI traffic is segmented on another VLAN, thus reducing the amount of traffic on each logical network. Use best practices to separate the ports for which the ProSoft modules are connected to on the IEC 61850 network to minimize the amount of multicast and GOOSE (Generic Object Oriented Substation Event) traffic to those switch ports. 14 Rockwell Automation Publication 3300A-RM001A-EN-P - October 2017

Connecting IntelliCENTER IEC 61850 Integration Unit Into the Plant Network Chapter 3 Testing, Sizing, and Characterization Guidelines for the IntelliCENTER IEC 61850 Integration Unit The integration unit is a flexible system that you can scale to fit multiple applications. Application size and system response requirements are the two main drivers that are used for the sizing of the integration unit for an application. This section discusses how the system was tested and suggests recommended settings for operation of the integration unit. Sample System It is recognized that most industrial and commercial power systems consist of various IEDs based on function. Systems can consist of feeder protection devices, motor protection devices, transformer protection devices, generator protection devices, intelligent circuit breakers, and power monitors. The testing of the integration unit is based on a 40 IED system that is shown in Figure 2. Figure 2 - Typical Industrial and Commercial Power System Utility Feed SEL 700G SEL 787 Transformer 1 SEL 700G G1 G2 SEL 710 SEL 710 SEL 787 Transformer 2 M1 M2 SEL 751A SEL 751A SEL 751A SEL 751A SEL 751A SEL 751A SEL 751A SEL 751A SEL 751A SEL 710 SEL 710 SEL 787 Transformer 3 M3 M4 SEL 751A SEL 751A SEL 751A SEL 751A SEL 751A This representative system consists of three voltage levels and on-site generation that feeds various loads and motors at both medium and low voltage. For this test, we use SEL 700 series IEDs (Schweitzer Engineering Laboratories) to provide traffic loading on the system. Specifically, we used SEL 700G, 787, 751A, and 710 IEDs for testing. Rockwell Automation Publication 3300A-RM001A-EN-P - October 2017 15

Chapter 3 Connecting IntelliCENTER IEC 61850 Integration Unit Into the Plant Network Test Configuration Table 1 and Table 2 describe the test setup that is used to benchmark the integration unit. Figure 3 depicts the test setup and configuration in graphical form. Table 1 - Hardware Requirements Part Number Quantity Vendor Fw Rev Description PLX82-EIP-61850 4 ProSoft Technology 1.03.001 EUT (Equipment Under Testing) 1756-L81E 1 Rockwell V30 Processor Automation 1783-BMS10CGN 2 Rockwell Automation 15.2(4)EA3(fc1) Stratix Managed Ethernet Switch 1756-A7 1 Rockwell 7-slot rack Automation 1756-PA72 1 Rockwell Automation Power Supply 1606-XLE240E 1 Rockwell Automation Power Supply Table 2 - Software Requirements Part Number Quantity Vendor Version Description DTM 1 Triangle Microworks V1.2.1.9 EUT (Equipment Under Testing) Studio 5000 1 Rockwell Automation V30 Processor programming tool EIP-61850 Configuration Manager 1 ProSoft Technology V2.0.0.22.0001 EUT configuration tool Wireshark 2 Wireshark V2.2.7 Network Protocol Analyzer 16 Rockwell Automation Publication 3300A-RM001A-EN-P - October 2017

Connecting IntelliCENTER IEC 61850 Integration Unit Into the Plant Network Chapter 3 Figure 3 - System Test Setup EIP Stratix 61850 Stratix EtherNet/IP Network 61850 Network EtherNet/IP Monitor The test system consists of four PLX82-EIP-61850 units transferring data between the IEC 61850 client (DTM tool) and the processor (1756-L81E). One Stratix switch connects to the IEC 61850 network, while another Stratix switch connects to the EtherNet/IP network. The Ethernet port that is connected to the 1756-L81E processor is mirrored so the personal computer can also monitor the EtherNet/IP data traffic. The personal computer captures the IEC 61850 and EtherNet/IP data traffic separately, which is merged through Wireshark. Configuration Overview These sections discuss the configuration guidelines. ProSoft Gateway Each PLX82-EIP-61850 unit is configured to communicate with ten simulated SEL (Schweitzer Engineering Laboratories) IEDs according to the configured IED description (CID) files that support the PlantPAx Rockwell Automation Library for Electrical Protection Devices faceplates. Figure 4 shows a sample configuration. Rockwell Automation Publication 3300A-RM001A-EN-P - October 2017 17

Chapter 3 Connecting IntelliCENTER IEC 61850 Integration Unit Into the Plant Network Figure 4 - Sample Configuration Each PLX82-EIP-61850 module is configured to read three reports and write eight controllable points from/to each IED. Table 3 shows the breakdown of attributes from each device and their assignment to each report. Table 3 - Device Attributes IEC 61850 Communication Method IEC 61850 Communication Overview Mode Dataset Data Count Report Buffered DSet01 41 data attributes Report Buffered DSet02 134 data attributes Report Buffered DSet03 32 data attributes Control Direct/Normal Security - 8 controllable points The DTM software simulates 40 IEDs based on the CID files from the Rockwell Automation Library for Electrical Protection Devices, publication PROCES-RM011. Table 4 provides a configuration overview of the relevant CID settings and IEC 61850 data traffic that the DTM tool generates. Table 4 - Configuration Overview Communication Method Attribute Description Buffered Report Count per IED 3 Buffered Report Trigger Options Data change (dchng) and Integrity Period (IntPd) (all reports) Buffered Report Integrity Period DSet01: 1000 ms, DSet02: 5000 ms, DSet03: 1000 ms Buffered Report Data change frequency 25% of the data attributes change data every 30 seconds Buffered Report Buffer Time 500 ms (all reports) Unbuffered Report Count per IED 0 GOOSE control block Count per IED 0 MMS read operation Count per IED 0 Control Count per IED 8 controllable points Control Operate frequency Each control operation is issued every 1000 ms 18 Rockwell Automation Publication 3300A-RM001A-EN-P - October 2017

Connecting IntelliCENTER IEC 61850 Integration Unit Into the Plant Network Chapter 3 EtherNet/IP Configuration Table 5 provides the information for the configuration of the EtherNet/IP network configuration for the ProSoft Gateway module within the integration unit. \ Table 5 - ProSoft Gateway Module EtherNet/IP Network Configuration Attribute Value Number of Connections (per EUT) 20 RPI Connection size Connection type 100 ms 500 bytes input / 496 bytes output Unicast Test Requirements The following logic is written in the ControlLogix controller: Class 1 connection timeout - Monitor the number of timeouts for each connection during the testing period. Report data update timing - Measure the maximum time interval without data change. Control operation - Trigger eight control operations for each IED every 1000 ms. Evaluation Criteria Table 6 shows the criteria that are used to evaluate a valid test of the system. Table 6 - Evaluation Criteria Test Criteria EtherNet/IP timeouts EtherNet/IP jitter Report timing Control timing IEC 61850 TCP/IP timeouts Pass Criteria No timeouts observed Within 5% of the requested RPI time Change 25% of data every 30 seconds Trigger eight commands each device every 1 second No timeouts that the EUT causes Test Results The following sections show the results for multi-module system and single module system testing. Rockwell Automation Publication 3300A-RM001A-EN-P - October 2017 19

Chapter 3 Connecting IntelliCENTER IEC 61850 Integration Unit Into the Plant Network Multi-module System Figure 5 defines the system stability for a system that contains 10 40 IEDs. The points within the chart represent test data that, where the actual measured RPI time, between the ProSoft Gateway module and the ControlLogix controller, is within 5% of the configured RPI time. As multiple, fully loaded modules are added within the system, the system scales linearly. Figure 5 - System RPI Settings 120 100 RPI Time [ms] 80 60 40 20 y = 0.4x + 55 R² = 0.8 RPI Setting [ms] Linear (RPI Setting [ms]) 0 0 10 20 30 40 Number of IEDs 50 20 Rockwell Automation Publication 3300A-RM001A-EN-P - October 2017

Connecting IntelliCENTER IEC 61850 Integration Unit Into the Plant Network Chapter 3 Single Module System Figure 6 defines the system stability for a system that contains between 1 10 IEDs. The points within the chart represent test data that, where the actual measured RPI time, between the ProSoft Gateway module and the ControlLogix controller, is within 5% of the configured RPI time. As IEDs are added to the module, the RPI response time scales linearly. Figure 6 - Loading of Single ProSoft PLX 82 Module See the IntelliCENTER Integration Unit Specifications Technical Data, publication 3300A-TD001 for specifications. Converged Plantwide Ethernet (CPwE) Guidelines For Connecting the IntelliCENTER IEC 61850 Integration Unit to PlantPAx Process Automation System The integration unit can be integrated into the PlantPAx distributed control system. The integration unit acts as another process skid or instrument to be connected into the overall PlantPAx architecture. The programmable controller within the integration unit is also considered like a remote terminal unit (RTU) within the process architecture. This information is directly produced to the HMI and the reporting layer while also producing the same data to other controllers for control operations within the system. For more information about the PlantPAx system architecture, consult the PlantPAx Distributed Control System Reference Manual, publication PROCES- RM001. Rockwell Automation Publication 3300A-RM001A-EN-P - October 2017 21

Chapter 3 Connecting IntelliCENTER IEC 61850 Integration Unit Into the Plant Network VLAN Segmentation Management (300) Native - Trunk (301) Supervisory Network (501) MCC I/O Network (502) Process I/O Network (503) RTU I/O Network (504) IEC 61850 Network (505) The PlantPAx Distributed Control System is a modern DCS which is scalable, flexible, and open while providing the reliability, functionality, and performance expected from a DCS. The PlantPAx System is capable of integrating control systems on process skidded equipments, process instrumentation, intelligent motor control and intelligent electrical protection devices. This drawing depicts a typical reference architecture for the PlantPAx System. Process Controllers responsible to handle Process I/O and Motor Control Center. Operator Workstations Virtual LANs provide the proper automation system segregation, where the critical communication is in the same subnet. Process Automation And Application Servers Figure 7 - System Architecture Routing capabilities such as Hot Standby Routing Protocol (HSRP) is used in secondary activities. NTP PTP Engineering Workstations Domain Controller NTP Process Automation And Application Servers NTP The Domain Controller is responsible to propagate the system time to computers and network infrastructure devices. Network Time Protocol (NTP) source can be internal or external, the GPS source (internal) is preferable in system where the time synchronization is critical. Skids of electrical protection devices can now be easily integrated into the PlantPAx System providing a holistic view of your plant s operations from power infrastructure through process control equipment. Intelligent Motor Control Devices PTP Process Control I/O Network Intelligent Electrical Protection Devices Simplex Integration When integrating into a simplex system, connect the uplink on the Stratix 5700 switch that is provided in the integration unit with the process level switch that is provided within the PlantPAx system architecture. Consult the PlantPAx Distributed Control System Reference Manual, publication PROCES-RM001 for further guidance on port configuration. See the Converged Plant-wide Ethernet (CPwE) Design and Implementation Guide, publication ENET-TD001 for network topology guidance. 22 Rockwell Automation Publication 3300A-RM001A-EN-P - October 2017

Connecting IntelliCENTER IEC 61850 Integration Unit Into the Plant Network Chapter 3 Redundant Integration When integrating into a redundant system, consider items including network architecture, controller size, and device ownership. Connect the uplink on the Stratix 5700 switch that is provided in the integration unit to the process level switch provided within the PlantPAx system architecture. Consult the PlantPAx Distributed Control System Reference Manual, publication PROCES-RM001 for further guidance on port configurations and controller sizing and impact for redundant systems. See the Converged Plant-wide Ethernet (CPwE) Design and Implementation Guide, publication ENET- TD001 for network topology guidance. Rockwell Automation Publication 3300A-RM001A-EN-P - October 2017 23

Chapter 3 Connecting IntelliCENTER IEC 61850 Integration Unit Into the Plant Network Notes: 24 Rockwell Automation Publication 3300A-RM001A-EN-P - October 2017

Index A abbreviations 5 Add-on Profiles 5 C configuration guidelines ProSoft gateway 17 connect integration unit 13 controller 21 CompactLogix 9 ControlLogix 9 converged plantwide Ethernet system See CPwE CPwE connect integration unit 21 redundant system 23 simplex system 22 DCS 9 D F faceplates 8 G gateway 13, 17 GOOSE subscriber functionality 14 I IEC 61850 gateway 10, 13 IEC 61850 network 13 IED 13, 15 IEEE C37.238 14 industrial Ethernet switch managed 10 Integrated Architecture 9 integrated power and automation See IPA integration unit 8, 9, 13 intelligent electrical devices See IED IPA 7 L layer 2 switch 10 M managed Ethernet switch 10 advanced security 10 diagnostics 10 network management 10 MMS client configuration 14 N network segmentation 13 O operator interface 11 P PlantPAx system 9 process object library 8 programmable controller 9 Q quality of service 14 R redundant system 23 Resilient Ethernet Protocol 10 RPI time 20, 21 S simplex system 22 size guidelines 15 T terminology 5 test guidelines 15 configuration 17 EtherNet/IP communication 19 IEC 61850 communication 18 system setup 15, 16, 17 test results RPI time 20, 21 time synchronization 14 trusted network 13 Rockwell Automation Publication 3300A-RM001A-EN-P - October 2017 25

Index U unified architecture 8, 13 untrusted network 10 uplink 22 V Virtual LAN 10 VLAN 14 WAN 10 W 26 Rockwell Automation Publication 3300A-RM001A-EN-P - October 2017

. Rockwell Automation Support Use the following resources to access support information. Technical Support Center Knowledgebase Articles, How-to Videos, FAQs, Chat, User Forums, and Product Notification Updates. https://rockwellautomation.custhelp.com/ Local Technical Support Phone Numbers Locate the phone number for your country. http://www.rockwellautomation.com/global/support/get-support-now.page Direct Dial Codes Literature Library Product Compatibility and Download Center (PCDC) Find the Direct Dial Code for your product. Use the code to route your call directly to a technical support engineer. Installation Instructions, Manuals, Brochures, and Technical Data. Get help determining how products interact, check features and capabilities, and find associated firmware. http://www.rockwellautomation.com/global/support/direct-dial.page http://www.rockwellautomation.com/global/literature-library/overview.page http://www.rockwellautomation.com/global/support/pcdc.page Documentation Feedback Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete the How Are We Doing? form at http://literature.rockwellautomation.com/idc/groups/literature/documents/du/ra-du002_-en-e.pdf. Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page. Allen-Bradley, CompactLogix, ControlLogix, FactoryTalk,GuardLogix, IntelliCENTER, PanelView, PlantPAx, Rockwell Automation, Rockwell Software, Stratix, Studio 5000, and Studio 5000 Logix Designer are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400 Publication 3300A-RM001A-EN-P - October 2017 Supersedes Publication Publication Number - Month Year PN-PN-123456 Copyright 2017 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.