Module 18plus. Description. 18plus

Similar documents
Thermal-Magnetic Circuit Breaker 2216-S

Thermal-Magnetic Circuit Breaker 4220-T...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

Electronic Overcurrent Protector REF16-S

Power distribution systems - accessories

Magnetic and Hydraulic-Magnetic Circuit Breaker

Operating Instructions Electronic Circuit Protector ESX10-TC-DC 12 V

Power distribution systems - accessories

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

REX12D Electronic Circuit Protector

Introduction Circuit Protection

Power distribution system SVS16-PB

Introduction Electronic Circuit Protection ESX10-T

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Solid State Remote Power Controller E

8WH5 Combination Plug-In Terminals

454 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA

1492-SP Supplementary Protectors

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

02/11/2015

Miniature Circuit Breakers for Railway Applications

Communication & Networking

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Classification Enclosure rating Input voltage Type of

DSE201, DSE201 M Compact design with enhanced protection

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

VZBs. Power PCB Relay RT2 2 pole 8 A, DC and AC-coil. Features. Contact data

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

NX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration

Solid-state Timer H3YN

Electronic timer CT-ERD.12

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

Protecting switching monitoring Automation technology and plant engineering

Modular Terminal Blocks and Terminal Strips with CAGE CLAMP, Series 260 to 262, Side-Entry

9926 Series Branch Rated Circuit Breakers AC Version

20 General technical data XI/ON

H3CR-F H3CR-F8 H3CR-F-300 H3CR-F8-300

E-STOP relays, safety gate monitors

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Power supply CP-C 24/5.0

Electronic timer CT-AHD.22

Residual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008

- 1 - Product catalogue PCB connection systems PCB terminals Clamping yoke connection LM 5.00 / 5.08 LM 5.00/135

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

PHOENIX CONTACT - 05/2007

Datasheet TERMSERIES Interface Adapter (TIA)

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

CLIPLINE complete. The modular terminal block system for all applications

for a perfect electrical installation. The range of rail-mounted terminal blocks

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

Slim Industrial Relay Type RSLM Electromechanical

LED Driver Linear / area fixed output

LED Driver Compact fixed output

Overvoltage Protection Devices

Electronic timer CT-ARS.11

Electrical Connection Technology. New Items: Autumn 2007

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

5SL Miniature Circuit Breakers

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

DX 3 MCB A / 16 ka 80 A to 125 A (1,5 module per pole)

Supplementary Circuit Protectors Type GSB63

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Powermate Range pitch 10.16

Datasheet - SLB 200-C04-1R

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

Section 4 Ground-Fault Protection Devices

The new Arc Fault Detection Device S-ARC1 Maximum safety easy installation

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

SLIMCON-6 24V DC POWERED ISOLATING SIGNAL CONVERTER

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

INSTRUCTION SHEET. Eaton Logic Controller ELCB Controllers

General Purpose Relays R2N/R4N Miniature Power Plug-in Relays

Solid State Remote Power Controller E /627

Power Supply HARTING pcon

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

Circuit Breakers Type CTI 25M, CTI 45MB

IELR Rail-Mount Series Magnetic Circuit Protectors

Transcription:

Module 8plus Description Wiring of load and signal lines in a space-saving manner will become ever more important for designers of electrical plants and systems, because all control cabinets and control boxes will have to be more and more compact due to the growing decentralisation of the entire automation technology. A significant cost reduction for the complete power distribution including wiring in the control cabinet will also play an important role. The module 8plus holds a complete mounting and power distribution system for DIN rail mounting which has, together with the busbars, a fully-featured 80 A power distribution of the DC 2 V control voltage without additionally required terminals and connection lines. It allows a cost-effective realisation of e.g. an -way protection system, because you only have plug in the required circuit breakers or protectors type 220-S, ESS0 or ESX0 into the ready slots of the connection modules. Each connection module can be operated with max. 20A load current. The signalling circuits of the individual devices for the group signalling by means of an integral auxiliary make contact are already pre-wired in this system. Line entry of the DC 2 V supply for LINE+, 0 Volt and functional earth FE is by means of plug-in type busbars. If no FE potential is supplied, all FE terminals may also be used as additional 0-Volt distribution. All electrical connections are made by means of push-in terminals with the following properties: l All conductors can be plugged in easily and without tools l Reliable contact making l Firm connection of the conductors due to high pull-out forces l Ease of operation with any tool l Contact reliability in the event of shock and vibration l Gas-tight connection l Maintenance-free All pushers were designed in four different colours (red, blue, orange, grey) so as to easily distinguish the different voltage potentials and functions of the device. Red = conductor: supply 2V/LINE+ or protected load output/load+ Blue = return conductor: supply 0 Volt or load/0 Volt Orange = functional earth supply FE Grey = signalling circuits: supply 2V/terminal or load/fe or signal output terminal, load terminal 7 Module 8plus can be used in combination with the following plug-in type overcurrent protection devices: l Thermal-magnetic circuit breaker 220-S l Electronic circuit breakers ESS20-00, ESS0-S00 l Electronic circuit protectors ESX0-0, ESX0-S0 Module 8plus consists of three different basic modules: - supply module 8plus-EM-... terminal (LINE +), terminal (0 V), terminal (FE) terminal (aux. contact input) - connection module 8plus-AM-... terminal 2./2.2 (LINE +), terminal./.2 (0 V), terminal./.2 (FE) - signalling module type 8plus-SM-... terminal (aux. contact output) terminal 7 (GND for integral signal load 0mA with indication) The connection module 8plus-AM has been designed to accommodate single pole circuit breakers and other overcurrent protection devices. Those will be plugged into the connection modules 8plus- AM. The single-way AM modules can be mounted side by side, enabling bigger distribution systems with up to 0 slots. Each AM module is fitted with mm² push-in terminals for double connection 8plus of DC 2 V loads via L+, 0V and FE, the max. load current is 20 A per slot. By mounting the individual connection modules 8plus-AM sideby-side, all internal wiring connections are established for the group signalling. The make contacts of the plugged in electro-mechanical or electronic circuit breakers are connected in series on this occasion. In addition, a 0 ma load is included in the signalling module 8plus-SM holding a green indication. This also enables the connection of PLC or ET200 inputs with a high internal resistance value. Module 8plus fitted with 220-S: The integral auxiliary contact (make contact) of the thermal-magnetic circuit breakers 220-S can be used for the group signalling. All required terminals (make contacts opening in the event of a failure) in the Module 8plus are connected in series for this purpose. Group signalling is realised via terminal integrated in the supply module, the signal output is located in the signal module 8plus-SM, terminal. An additional signal load of 0 ma can be realised via the 0 V terminal of the control at terminal 7. Module 8plus fitted with ESS20-00 or ESS0-S00: The 0V reference potential of the connection module 8plus-AM for the ESS20 or the ESS0-S is already directly connected to the 0V potential of the supply terminal 8plus-EM and is then looped through to the next AM element over the blade terminals on the side. This means: The side-by-side mounting (plug together) of the individual AM modules simultaneously establishes all internal wirings for the 0 V potential and for the group fault indication (series connection of make contacts). The ESS20-00 or ESS0-S00 have an integral auxiliary contact (change over contact). The contact SC-S0 is used for the group fault indication. For this purpose the contacts for this signalling are already connected in series in the 8plus modules. These are connected via two terminals (supply in 8plus-EM) and (output in 8plus- SM). Module 8plus fitted with ESS0-0/ESX0-S0: The 0 V reference potential of the connection module 8plus-AM for the ESX0-0 or the ESX0-S0 is already directly connected to the 0 V potential of the supply terminal 8plus-EM and is then looped through to the next AM element over the blade terminals on the side. This means: The side-by-side mounting (plug together) of the individual AM modules simultaneously establishes all internal wirings for the 0 V potential and for the group fault indication (series connection of make contacts). The ESX0-0 or ESX0-S0 have an integral auxiliary contact (change over contact). The contact SC-S0 is used for the group fault indication. For this purpose the contacts for this signalling are already connected in series in the 8plus modules. These are connected via two terminals (supply in 8plus-EM) and (output in 8plus- SM).

Module 8plus Technical Data Plug-in type circuit breakers 220-S; ESS20-00, ESS0-S00; ESX0-0; ESX0-S0; Rated voltage AC 250 V; DC 2 V (optional to DC 80 V) IEC 097-7- 00 V / 0 V (UL 059) Rated AC 250 V insulation voltage Main circuit, rated current I N supply module 80 A (IEC 097-7-) 5 A (UL059) connection module 20 A (IEC 097-7-) A (UL059) Signal circuits, rated current I N min. current (terminals ) min. 0 ma at DC 0 V max. current max. A at DC 2 V integral current load (terminals 7) typically 2 ma at DC 2 V Busbar for power distribution insulated busbar I max. 80 A (5 A UL 059) Ambient temperature -0 C... +0 C Installation temperature +5 C... +0 C Storage temperature -0 C... +70 C Mounting position as desired Creepage resistance PTI 00 Mounting symmetrical rail EN 50022-5x7.5 symmetrical rail EN 50022-5x5/.5 supply module EM push-in terminal PT terminals (; ; ) 0.5 mm 2 ; rigid (without) wire end ferrule* 20 ; AWG 0.5 mm 2 ; flexible (without) wire end ferrule* 20 ; AWG 0,5 mm 2 ; flexible with wire end ferrule* without plastic sleeve 0.5 mm 2 ; flexible with wire end ferrule* with plastic sleeve terminals (; 5; ) push-in terminal PT 0.2 mm 2 ; rigid (without) wire end ferrule* 2 2; AWG 0.2 mm 2 ; flexible (without) wire end ferrule* 2 2; AWG 0,25 mm 2 ; flexible with wire end ferrule* without plastic sleeve 0.25 mm 2 ; flexible with wire end ferrule* with plastic sleeve connection module AM push-in terminal PT terminals 0.2 mm 2. ; rigid (without) wire end ferrule* (2.; 2.2;.;.2;.;.2) 2 2; AWG 0.2 mm 2 ; flexible (without) wire end ferrule* 2 2; AWG 0,25 mm 2 ; flexible with wire end ferrule* without plastic sleeve 0.25 mm 2 ; flexible with wire end ferrule* with plastic sleeve signalling module SM push-in terminal PT terminals (; 5; ) 0.2 mm 2 ; rigid (without) wire end ferrule* 2 2; AWG 0.2 mm 2 ; flexible (without) wire end ferrule* 2 2; AWG 0,25 mm 2 ; flexible with wire end ferrule* without plastic sleeve 0.25 mm 2 ; flexible with wire end ferrule* with plastic sleeve Technical Data Wire stripping length Push-in terminal PT 8 mm Push-in terminal PT mm Insulation co-ordination (IEC 0-) Main circuit rated impulse voltage kv pollution degree Overvoltage category III Auxiliary circuit rated impulse voltage 0,8 kv pollution degree Overvoltage category III Dielectric strength Main circuit to main circuit 500 V Main circuit to auxiliary circuit 500 V Auxiliary circuit to auxiliary circuit 500 V Insulation resistance > 00 MΩ (DC 500 V) Typical internal resistance values Main circuit (EM AM2./2.2); without device 5 mω Auxiliary circuit ( x EM, x AM, x SM); without device 0 mω; ( / make contact) (+5 mω for each added AM) Typical mounting values (circuit breaker) Typical push-in force approx. 0 N Typical pull-out force approx. 50 N Number of push-on operations devices 50 busbar 20 Mass Module 8plus EM approx. 70 g Module 8plus AM approx. 0 g Module 8plus SM approx. 5 g Vibration (sinusoidal) test to IEC 008-2-, test Fc 5 g (57-500Hz), ± 0,8 mm (0-57 Hz) Shock test to IEC 008-2-27, test Ea 25 g ( ms) Humidity test to IEC 008-2-78, test Cab 20 hrs. in 95% RH Corrosion Test to DIN IEC 008-2-, test Ka 9 hours in 5% salt mist *) Application note: We recommend a square crimp shape when using wire end ferrules. Approvals Approval authority UL CE logo Standard Rated voltage Current ratings UL059, CSA C22.2, No. 58 00 V / 0 V (signal) CE logo according to EN 097-7- 5 A / A / A (signal) 2

Module 8plus Features and Benefits l Complete mounting and power distribution system for rail mounting l Together with the busbars it holds a fully-fledged 80A potential distribution of the DC2V control voltage without additionally required connection terminals or connecting cables l All electrical connections are implemented via screwless push-in terminals. All pushers were designed in four different colours (red, blue, orange, grey) so as to easily distinguish the different voltage potentials and functions of the device. Supply terminals PLUS connecting terminals PLUS signalling terminals PLUS integral wiring harness PLUS flexible circuit breaker population...... mutually complete their effects l Modular compact system for rail mounting as a complete package, containing l Load wiring with integral terminals without additional potential distribution l Plug-in type overcurrent protection for all requirements in the DC 2 V area l Integral power distribution up to 80 A l Integral group signal wiring, make contacts l Future bus connection for ControlPlex applications l Push-in terminals for reliable wiring, even with shock and vibration Available versions 8plus-EM02-00- PT0-0 8plus-AM02-00- PT0-0 8plus-SM02-0- PT0-0 8plus supply module, compact version with group signalling make contact 8plus connection module for circuit breaker types 220-S, ESS20-00, ESS0-S00, ESX0-0/ESX0-S0, compact version with group signalling make contact 8plus signalling module for compact version with group signalling make contact, with integral signal load 0mA User benefits l Saves component costs for wiring and for additional parts because the cable harness and the potential distribution are already included l Reduces costs through ease of electrical planning, of mounting in system and plant service, of procurement etc. l Perfectly matches centralised and decentralised power distribution concepts l Saves expenses in logistics through use of only few, standardised components l High application flexibility through population with different circuit breaker models

Module 8plus Mounting Disassembly Removing the busbars:. 2.. Push away signalling module to remove busbar 2. Pull busbar out of the groove Removing the modules: Mounting the modules:. 2. 2.. Snap module onto rail 2. Push modules on the rail until they catch on audibly.. Push modules apart 2. Remove module from rail: put screwdriver with a mm blade to foot Mounting the busbars:.. When all modules are positioned correctly, insert busbars in correct position until stop

Module 8plus Dimensions of socket system Dimensions EM Symmetrical rail EN 50022-5x Label optional,5 n x 58,,5 2,5 2,5, Knock-out protection against brush contact Label optional Dimensions AM Dimensions SM 58,,7 2,5, 2,5 Wiring diagram, without circuit breakers PE N L AC DC2V - - + + 8plus-EM0-00-PT0-0 8plus-AM0-00-PT0-0 8plus-SM0-00-PT0-0 e.g. ST -PE X X X X b a b a b X X a X X X b ba b a a a b a X X X X2. X2. X2. X2. X2. X2. 2. 2.2 2. 2.2 2. 2.2..2..2..2 7..2..2..2 Mass for current load SIFA on I/O module 5

220-S/ESS20-... - Module 8plus Dimensions, with 220-S Dimensions, with ESS20-00 (max. 5 mm) ON 8 (OFF ) Schematic diagram, with 220-S Schematic diagram, with ESS20-00 EM AM......AM SM EM AM......AM SM > > > > 2,2 220 2,2 220 2,2 ESS20-00 2,2 ESS20-00 7 7 EM line 0 Volt FE signalling SM signalling 7 load 2 V / 0 ma EM line 0 Volt FE signalling SM signalling 7 load 2 V / 0 ma AM 2., 2.2 load.,.2 0 Volt.,.2 FE AM 2., 2.2 load.,.2 0 Volt.,.2 FE Pin assignment, with 220-S Pin assignment, with ESS20-00 220-S.. (n.a.) 2 module 8plus compact 2 2 (n.a.) 2 2., 2.2 ESS20.. module 8plus compact LINE (+) GND SC SO SI (n.a.) LOAD (+) 2., 2.2

ESS0-S.../ESX0-... - Module 8plus Dimensions, with ESS0-S00 Dimensions, with ESX0-0 / ESX0-S0 With optional retaining clip: 07 (OFF ) 0 Schematic diagram, with ESS0-00 Schematic diagram, Type ESX0-0 / ESX0-S0 EM AM......AM SM EM AM......AM SM 2,2 ESS0-S00 2,2 ESS0-S00 2,2 ESX-0...-S0 2,2 ESX-0...-S0 7 7 EM line 0 Volt FE signalling SM signalling 7 load 2 V / 0 ma EM line 0 Volt FE signalling SM signalling 7 load 2 V / 0 ma AM 2., 2.2 load.,.2 0 Volt.,.2 FE AM 2., 2.2 load.,.2 0 Volt.,.2 FE Pin assignment, with ESS0-S00 ESS0-S00 module 8plus compact LINE (+) GND SC SO SI (n.a.) LOAD (+) 2., 2.2 Pin assignment, with ESX0-0 / ESX0-S0 ESX0-0 ESX0-S0 LINE (+) GND SC module 8plus compact SO SI (n.a.) LOAD (+) 2., 2.2 7

Module 8plus Accessories Busbar X 222 02 FTG-Busbar X 22 57 0 500 busbar for LINE, 0 V, FE, grey insulation, 500 mm busbar for LINE, 0 V, FE, grey insulation, 500 mm Retaining clip Y 978 0 Retaining clip for ESS0-S Installation example with ESS0-S with optional retaining clip Jumper SB-S-P-0--A top view Germany Signalbrücke Signal loop SB-S-P-0--A www.e-t-a.com xxxx 0 70 Signalbrücke Signal loop AC 20 V / DC 5 V, A 2 2, 0, contakt + bridged blade terminal DIN 2-A,-0,8 Retaining clip Y 07 75 0 Retaining clip for ESS20 / ESX0 / SB-S-P-0--A 8,5,7, 2,8 8 Mounting example for the reatining clip with ESS20 All dimensions without tolerances are for reference only. E-T-A reserves the right change specifications at any time in the interest of improved design, performance and cost effectiveness, the right to make changes in these specifications without notice is reserved. Product markings may not be exactly as the ordering codes. Errors and omissions excepted. 8