Revision. Decentralized Drive Systems MOVIMOT MM..D with AS-Interface * _0817*

Similar documents
* _0817* Drive Technology \ Drive Automation \ System Integration \ Services. Revision. Decentralized Drive Systems MOVIMOT MM..

Revision. Drive System for Decentralized Installation Fieldbus Interfaces, Field Distributors * _0717*

Revision to the Operating Instructions

Addendum to the Operating Instructions

Addendum to the Operating Instructions

Drive Technology \ Drive Automation \ System Integration \ Services. Quick Start Guide. MOVIMOT MM..D With DRS/DRE/DRP AC Motor

Revision. MOVIPRO with EtherNet/IP or Modbus TCP Fieldbus Interface * _1017*

Revision to the Operating Instructions

Compact Operating Instructions

* _1017* Drive Technology \ Drive Automation \ System Integration \ Services. Revision. MOVIPRO SDC With PROFINET Interface

Revision. Decentralized Drive and Application Control MOVIPRO ADC with PROFINET interface * _1017*

Revision to Manual

* _1118* Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Interface Adapter USM21A

Compact Operating Instructions

Revision. Drive and Application Controller MOVIPRO PHC2.A-A..M1-..2A-C5 * _1117*

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety

Addendum to the Manual

Operating Instructions

Operating Instructions

Compact Operating Instructions

* _0315* Drive Technology \ Drive Automation \ System Integration \ Services. Brief Instruction. Data & Documents

* _1216* Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Electronic Motor DRC..

Manual. MOVITRAC LTE-B+/LTP-B Accessories Keypads, Parameter Module, Cable Sets * _0618*

Operating Instructions

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Electronic Motor DRC Functional Safety

Compact Manual. Drive System for Decentralized Installation EtherNet/IP Interfaces, Field Distributors * _1115*

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVITRAC MC07B Functional Safety

Manual. Decentralized Extra-Low Voltage Servo Drive CMP ELVCD Functional Safety * _0717*

Operating instructions. Standstill monitor A / / 2011

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Manual. Decentralized Drive Control MOVIFIT FDC-SNI Connection to PROFIBUS/DeviceNet with UFF41B Fieldbus Gateway

Operating instructions

AS-i Safety Relay Output Module with Diagnostic Slave

P216 Series Condenser Fan Speed Controller

Operating instructions. Speed monitor D / / 2014

Manual. MOVIMOT MM..D Functional Safety (including field distributor) * _0516*

Addendum to the System Manual. MOVIGEAR SNI Expanded Parameter Setting and Diagnostics with MOVITOOLS MotionStudio. Edition 01/ / EN

Compact Operating Instructions MOVIDRIVE MDR60A/61B Regenerative Power Supply Unit

User manual Technical parameters

Operating Instructions

AS-i Safety Relay Output Module with Diagnostic Slave

Accessories for stand-alone gird inverter SMART LOAD 6000

Operating instructions. Switching amplifier DN0210 DN / / 2015

Product Manual. Safety-Related Subsystem MOVISAFE prog. FSSS-HC/HW-POS-DCS * _0917*

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

Installation Instructions

Power supplies.

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

* _0718* Drive Technology \ Drive Automation \ System Integration \ Services. Revision. UHX71B Controller (Power Performance Class)

MDM 011-Z1 Regen Resistor

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Manual. MOVIAXIS MX Multi-Axis Servo Inverter Virtual Encoder Technology Function. Edition 05/ / EN

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Operating Manual DriveConfigurator

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

P216. Condenser fan speed controller. Product bulletin. Features

Compact Operating Instructions MOVITRAC B

DF PROFI II CPCI. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II CPCI KUNBUS

Operating Instructions. MOVIMOT MM..D With AC Motor DRS/DRE/DRP. Edition 12/ / EN

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

Electromotoric actuators

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Operating Manual -ENGLISH- Page 1 KWG-ISO

Operating Instructions

Application Technique. Safety Function: Safety Camera with E-stop

User Manual Digital Input Module

PHOENIX CONTACT - 07/2006

3+1 U CPCI Serial System

Drive inverter for asynchronous AC motors without encoder feedback. The units are not option capable.

FOR SERVICE TECHNICIAN S USE ONLY

MC 11 EB-2 Power supply cabinet with external bus, AC version

Field module for cold locations for installation in refrigerators for direct control of a pulsed expansion valve

CPCI System Subrack 1 U

Keystone OM3 - EPI-2 Local Interface Module Installation and Maintenance Instructions

Industrial motor controller for brushed DC motors 24 VDC

MINI-PS AC/10-15DC/8

Mounting Instruction. Industrial Ethernet Workgroup Switch MACH104 Full Gigabit Family. Mounting Instruction MACH104 Release 07 07/2014

Compact Manual. Drive System for Decentralized Installation InterBus Interfaces and Field Distributors

Installation, Operation and Maintenance Manual

User Guide. Please read these instructions carefully before use

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVITRAC MC07B Functional Safety

Smart Grid Tie Microinverter User Manual

LED W RGBA User Manual

Electrical Actuators

MED MI 1005 Network Isolators

VISY-Output 8. Technical Documentation. 8-Channel relay output module. Version: 3 Edition: Art. no.:

RUC industrial relays of small dimensions

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

Room Temperature Controller

Unidrive M400 (Frame 1 to 4) Quick Start Guide

Electrical Actuators

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

IO-INTERFACE. Procon. INSTALLATION MANUAL Version 1.01 MITSUBISHI ELECTRIC FOR INSTALLERS

QUINT-BUFFER/24DC/24DC/40

Table of Contents Product Overview Before using the product Installation Procedure... 5

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Transcription:

Drive Technology \ Drive Automation \ System Integration \ Services *23583657_0817* Revision Decentralized Drive Systems MOVIMOT MM..D with AS-Interface Edition 08/2017 23583657/EN

SEW-EURODRIVE Driving the world

Amendments/revisions Type designation of the design "mounted close to the motor" 1 1 Amendments/revisions The following documentation has been amended and revised. Observe the data specified in this revision. This document does not replace the detailed operating instructions/compact operating instructions. "MOVIMOT MM..D with AS-Interface" operating instructions "MOVIMOT MM..D with AS-Interface" compact operating instructions 1.1 Type designation of the design "mounted close to the motor" 1.1.1 Nameplate Order-specific nameplate The following figure provides an example of an order-specific nameplate of the MOVIMOT inverter for mounting close to the motor: Made in Germany Feldverteiler Field Distributor 01 S0#: Type: Input: P-Motor = 3,0kW 95.7416041003.0001.17 MM30D-503-00/0/P22A/RR4A/ AVSK/APG4/MLK IP65 ML0001 U= 3x380...500V I= 6,7A AC C U L US LISTED IND.CONT.EQ. 2D06 General nameplate The following figure provides an example of a general nameplate of the MOVIMOT inverter for mounting close to the motor: Input: U= 3x200...500V Imax= Input: U= 3x200...500V Imax= 3,5...7,3A AC f= 50...60Hz Output to next Field Distributor: U= Imax= Output to drive: U= 3x0...Uinput Imax= 4,0...8,7A AC P-Motor= 1,5...4,0kW 23583657/EN 08/2017 Revision MOVIMOT MM..D with AS-Interface 3

2 Mechanical installation Mounting position 2 Mechanical installation 2.1 Mounting position Install the MOVIMOT inverter MM40D (4 kw) in mounting position M2 (heat sink on bottom, see right figure) close to the motor only if ambient temperatures are ϑ u 35 C. ϑ u 35 C MM40D 20870741899 23583657/EN 08/2017 4 Revision MOVIMOT MM..D with AS-Interface

X1: 13 X1: 14 X1: 15 Connection of MOVIMOT options Electrical installation Connection of MOVIMOT options 3 3 Electrical installation 3.1 Connection of MOVIMOT options 3.1.1 Connection of forced cooling fan V AC motors of the DR.. series are optionally available with forced cooling fan V and MOVIMOT with MLK30A/MLK31A (only with plug connector AVSK or AZZK). Using the forced cooling fan V extends the setting range of the setpoint speed. This means that speeds from 150 min -1 (5 Hz) can be realized continuously. INFORMATION For motors with forced cooling fans V, parameter P341 Type of cooling must be set to "forced air cooling". When using MOVIMOT drives with functional safety (STO), do not connect the forced cooling fan to the connection box. Instead, use an external DC 24 V supply to supply the forced cooling fan with power. The following figure shows the cable entry of the forced cooling fan cable: (Only for MOVIMOT drives without functional safety.) 18014401679145483 The following figure shows an example connection for the forced cooling fan V: (Only for MOVIMOT drives without functional safety.) X1: L1 X1: L2 X1: L3 MOVIMOT 23583657/EN 08/2017 DC 24 V AS+ X6: 8 AS- X6: 7 X6: 6 X6: 5 X6: 3,4 X6: 1,2 DI2 DI3 V024 V0 24V X5: 2a,2b X5: 1a,1b 24 V RD BU 9007212132283659 Revision MOVIMOT MM..D with AS-Interface 5

4 Startup of MOVIMOT with MLK.. in Easy mode Description of the DIP switches S1 4 Startup of MOVIMOT with MLK.. in Easy mode INFORMATION When selecting Easy mode, you up MOVIMOT using switches f2, t1. 4.1 Description of DIP switches S1 4.1.1 DIP switch S1/6 Motor with 50/60 Hz voltage range Applies to MOVIMOT with the following drive ID modules: Designation Drive ID module Identification color Part number Line voltage V Motor DRS/DRE/50/60 Violet 18214444 220 240/380 415 254-277 V / 440-480 V DRS/DRN/50/60 Pastel green 28241827 220 230/380 400 266/460 Setting of DIP switch S1/6: Power Motor type MOVIMOT inverter MM..D-503-00 Motor in W connection Line frequency Hz 50 60 50 60 Motor in m connection kw S1/6 = OFF S1/6 = ON S1/6 = OFF S1/6 = ON 0.25 DR63L4/.. MM03D.. MM03D.. MM05D.. 0.37 DRS71S4/.. MM03D.. MM05D.. MM05D.. MM07D.. 0.55 DRS71M4/.. MM05D.. MM07D.. MM07D.. MM11D.. 0.75 1.1 1.5 2.2 3.0 4.0 DRE80M4/.. DRN80M4/.. DRE90M4/.. DRN90S4/.. DRE90L4/.. DRN90L4/.. DRE100L4/.. DRN100LM4/.. DRE100LC4/.. DRN100L4/.. DRE132S4/.. DRN112M4/.. MM07D.. MM11D.. MM11D.. MM15D.. MM11D.. MM15D.. MM15D.. MM22D.. MM15D.. MM22D.. MM22D.. MM30D.. MM22D.. MM30D.. MM30D.. MM40D.. MM30D.. MM40D.. MM40D.. MM40D.. 23583657/EN 08/2017 6 Revision MOVIMOT MM..D with AS-Interface

Operation Operating notes 5 5 Operation 5.1 Operating notes WARNING Electric shock caused by dangerous voltages at the connections, cables and motor terminals. When the device is switched on, dangerous voltages are present at the connections as well as at any connected cables and motor terminals. This also applies even when the device is inhibited and the motor is at standstill. Severe or fatal injuries. Do not switch under load. Before performing any work on the device, disconnect it from the voltage supply. Note that dangerous voltages can occur at the terminals and connections for up to 1 minute after the controller is switched off. Block the output stage of the inverter before switching at the output of the device. WARNING Electric shock from capacitors that have not been fully discharged. Severe or fatal injuries. Disconnect the inverter from the power. Observe the minimum switch-off time after disconnection from the supply system: 1 minute WARNING Risk of crushing if the motor starts up unintentionally. Severe or fatal injuries Observe the startup instructions. Deactivate all control signals. WARNING Danger of burns due to hot surfaces of the device (e.g. the heat sink). Serious injuries. Do not touch the device until it has cooled down sufficiently. INFORMATION The maximum output frequency in any operating mode is 120 Hz. 23583657/EN 08/2017 If the maximum output frequency is exceeded, the status LED of the MOVIMOT inverter flashes slowly red (error 08 "speed monitoring"). Revision MOVIMOT MM..D with AS-Interface 7

6 Service Inspection and maintenance 6 Service 6.1 Inspection and maintenance 6.1.1 Repairs Only SEW-EURODRIVE is authorized to carry out repairs. 23583657/EN 08/2017 8 Revision MOVIMOT MM..D with AS-Interface

Technical data Assignment of the drive ID module 7 7 Technical data 7.1 Assignment of the drive ID module Motor Drive ID module Designation Type Line voltage Line frequency Identification color Part number V Hz DRS.. 230/400 50 DRS/400/50 White 18214371 DRE 230/400 50 DRE/400/50 Orange 18214398 DRS.. 266/460 60 DRS/460/60 1) Yellow 18214401 DRE 266/460 60 DRE/460/60 1) Green 18214428 DRS/DRE 220/380 60 DRS/DRE/380/60 1) Red 18234933 DRS/DRE 220 240/380 415 254 277/440 480 50 60 DRS/DRE/50/60 Violet 18214444 DRP 230/400 50 DRP/230/400 Brown 18217907 DRP 266/460 60 DRP/266/460 1) Beige 18217915 DRU...J 230/400 50 DRU...J/400/50 Gray 28203194 DRN.. 230/400 50 DRN/400/50 Light blue 28222040 DRN.. 266/460 60 DRN/460/60 Blue green 28222059 DRS/DRN 220 230/380 400 266/460 50 60 DRS/DRN/50/60 Pastel green 28241827 1) This drive ID module can also be combined with MOVIMOT MM..D-233. 23583657/EN 08/2017 Revision MOVIMOT MM..D with AS-Interface 9

8 Declaration of conformity 8 Declaration of conformity EU Declaration of Conformity Translation of the original text SEW-EURODRIVE GmbH & Co. KG Ernst-Blickle-Straße 42, D-76646 Bruchsal declares under sole responsibility that the following products 900030410/EN Frequency inverters of the product family in accordance with MOVIMOT MM..D-..3-.. MOVIMOT.../MM../... Machinery Directive 2006/42/EC (L 157, 09.06.2006, 24-86) This includes the fulfillment of the protection targets for "electrical power supply" in accordance with annex I No. 1.5.1 according to the Low Voltage Directive 73/23/EEC -- Note: 2014/35/EU is currently valid. EMC Directive 2014/30/EU 4) (L 96, March 29, 2014, 79-106) RoHS Directive Applied harmonized standards: 2011/65/EU (L 174, July 1, 2011, 88-110) EN ISO 13849-1:2008/AC:2009 EN 61800-5-2:2007 EN 61800-5-1:2007 EN 61800-3:2004/A1:2012 EN 50581:2012 4) According to the EMC Directive, the listed products are not independently operable products. EMC assessment is only possible after these products have been integrated in an overall system. For the assessment, the product was installed in a typical plant configuration. Bruchsal Place 20.07.2017 Date Johann Soder Managing Director Technology a) Authorized representative for issuing this declaration on behalf of the manufacturer b) Authorized representative for compiling the technical documents a) b) 23583657/EN 08/2017 10 Revision MOVIMOT MM..D with AS-Interface

SEW-EURODRIVE Driving the world SEW-EURODRIVE GmbH & Co KG P.O. Box 3023 76642 BRUCHSAL GERMANY Phone +49 7251 75-0 Fax +49 7251 75-1970 sew@sew-eurodrive.com www.sew-eurodrive.com