GNS-MC35iT, GNS-MC35iU Terminals datasheet

Similar documents
EDW-ML8021 GSM GPRS Modem User s Manual. Page 1

irz MC55iT GPRS class 10 GSM modem USER MANUAL

SENECA s.r.l. Commercial

Product description Rev. 3 11/06/14

Control equipment. Installation & maintenance

Product description The SWH is a board Cellular Terminal solution for GSM GPS/GLONASS

Operation Manual GSM modem irz TG42-232

EZ864 UMTS Terminal Telit Cellular GSM Engine

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview

GT- IRDM-9603 Product description Rev. 2 17/06/2014

AQ_G24 GSM Terminal Card Motorola Cellular GSM Engine

Document Name : User Manual for SC10B : RS232 to Bluetooth Converter.

S2C Link Accessory Kit Datasheet

Hardware Interface Description

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V

Hardware Interface Description. Java Box Terminal Motorola G24 Cellular + GPS Engine

OnCell G3100 Series Quick Installation Guide

Bluetooth TO Serial CONVERTER E-P132-B

MPCIE-3G Quick Installation Guide

Hardware Interface Description

Manual Fiber Optic Interfaces

Contents 1. Introduction General Information Connecting, configuring and management Emergencies Support...

Industrial Quad-band GPRS/GSM Modem GTM-201 Series. User Manual

Bluetooth to RS-232 Converter. RT-132B Bluetooth Adaptor Operation Manual

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

ZM24x Quick-Connect Industrial Modem. User s Manual

Select a Data Communication Interface

Aarlogic TER-GX910. Product description. Rev.9 17/03/2013

Manual Industry Interfaces

The Wireless Connectivity Expert

PCI Express 16-Port Serial I/O Cards

ZM56 High-Speed Industrial Modem. Command Summary. 1 ZM56 High-Speed Industrial Modem

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

Preliminary. PACKAGE - 28-pin MLP (5mm X 5mm) Example Circuit Diagram CP V. 48MHz Oscillator. USB Function Controller 512B EEPROM

Installation & Configuration manual. InduBox GSM IV

USER MANUAL HPS-120. About this product: Your Communications Solutions Provider

USR-GPRS-MODEM user manual

EZmoto V4.1 Product description Rev. 2 30/07/2015

WiFi to RS-232 adapter user manual

LM058 Bluetooth Serial Adapter SMA Antenna 100m m Range SPP GAP + Wireless DTR DSR RTS CTS

ISDN OEM1. DesignGuide V1.2

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

MEV Limited USB232/485 INSTRUCTION MANUAL

EZL-200F Application Notes (003) Serial Interface (RS232/RS422/RS485)

W&T Manual Interface modules W&T

Installation and Configuration Quick Guide GoRugged M1000 MP

Four-Faith Smart Power Technology Co., Ltd. F1103 GPRS MODEM USER MANUAL

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

EX & EX-45362IS 2S RS232/422/485 3-in-1 Serial PCIe Card

Sender Receiver Sender

IComSat v1.0. -SIM900 GSM/GPRS shield

Features. Preliminary. Industrial IEEE b/g/n with 2x10/100Base-T(X) 1x RS-232/422/485 IoT LTE LPWAN Gateway. Introduction

HCP - LC RS232 (BG2-E) datasheet

+70 C -25 C 95% RH EMC

TELETERM M2 Series Programmable RTU s

IML 560 USER GUIDE. Low Power 56Kbps Industrial modem. Version 1.2. December 6, AYANTRA Inc.

Brief Instruction. 4.2 ISDN devices. 4.2 GSM devices MDH 502 MDH 536 MDH 506 MDH 512 MDH 542 MDH 522

C55/C55i Hardware description

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015)

Hardware Manual. for the PCD3.F2xx serial interface modules. Controls Division. Document-No. 26/857; Version EN2;

TELESERVICE. Teleservice with TS Adapter IE. Page 1864 Mar 2008 Siemens ITS

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Industrial Tri-band 3G Modem GTM-201-3GWA Series. User Manual

V2400 Series Expansion Modules

User Manual for VE GSM Modem

LM058 Bluetooth v2.0, v2.1 RS232 Serial Adapter - SMA Connector Standalone (With Embedded Bluetooth v2.0 / v2.1 Stack)

General Operating, Maintenance and Installation Manual

PCIe-400 USER S MANUAL

Product Manual. USB to Optical Adapter Industrial Isolated RS- 232/422/485. Coolgear, Inc. Version 2.1 December 2018 Model Number: USB-COMi-Si-M

TELTONIKA ModemCOM (TMC-10x) User Manual V

Dual Serial Shield User Manual

SNR610. Embedded network node module SNR610. Description. Feature. Application. SNR610 is highly integrated network module.

Dual Band 2G / 3G Wireless Terminal

LM058 Bluetooth Serial Adapter

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

BeagleBone Black USB Expansion RS232 Module Cape Coolgear, Inc. Version 1.1 September 2017 Model Number:

UB603 Four Band GSM/GPRS Module. Hardware Manual. July 2010

MLB-G1101 DTU User Guide

IDS-141A/181A. Industrial 4-port/8-port slim type serial to Ethernet device server. Features. Introduction. DS-Tool

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

USER MANUAL. G.shdsl+ modem with G.703 interface TAHOE 671 FREEDOM OF COMMUNICATION

T1K MODBUS Base Controller Specifications

SCB-C08 USB to RS232/422/485 Converter

Industrial terminal Hit65T

Hit Copyright

Chapter 11: Input/Output Organisation. Lesson 05: Asynchronous RS232C Serial Port data transfer

Product Manual. USB BAY-4 Port Serial DB- 9 RS-232 Adapter with FTDI Chipset. Coolgear, Inc. Version 1.1 September 2017 Model Number: USBG-BAY4

PCI Express 4-Port Industrial Serial I/O Cards

UniMod GSM-3. Operation Manual

Serial Interfaces Part 1. ECE 153B Sensor & Peripheral Interface Design Winter 2016

GSM 4 click MIKROE Weight: 33 g

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

ISDN - SOC. DesignGuide. Rev 2.2

MODEL DSU Kbps Rack Mount CSU/DSU OPERATOR S MANUAL. 280 I-80 West Exit 1 PO Box 1330 Verdi NV 89439

A TECHNICAL INFO A. External GSM AT420 DATE :

Media Converters. Media Converters. Product Selection Guides

1) GSM/GPRS/EDGE/HSDPA/HSUPA/CDMA/GPS modems/ modem pool and modem cards

Document history. 18th April 2012 : Start Version th Nov 2012 : Change to Smart SAM2W Version 1.1

DinBox M36 Hardware Description Guide

Transcription:

datasheet 2007

Contents Document history...3 1 Abstracts...4 2 Key features...4 3 Electrical and environmental characteristics...5 4 Operating modes...7 5 Power supply...8 6 Power on/off control...9 7 RS232 interface...9 8 USB interface...10 9 Coding of the status LED...10 2

Document history Document version What s changed 3

1 Abstracts GNS-MC35iT (GNS-MC35iU) terminals is GSM terminals, based on Siemens MC39i module. If not called exactly, all of GNS-MC35iT and GNS-MC35iU are called terminals in this document. Terminals are intended for: - Data, SMS, Fax transmittion using GSM network - Internet access - Installation inside equipment that need internet access or wireless data exchange 2 Key features Table 1. Key features of terminals Feature Implementation Transmission Data, SMS, Fax Power supply Single supply voltage 8V to 28V GSM class Small MS - Dual Band E-GSM 900 and GSM 1800 Frequency bands - Compliant to GSM Phase 2/2+ - Class 4 (2W) for EGSM900 Transmit power - Class 1 (1W) for GSM1800 GPRS multi-slot class 10 GPRS connectivity GPRS mobile station class B SIM card reader Internal Connected via antenna FME connector External antenna antenna resistance 50Ώ MT, MO, CB, Text and PDU mode SMS SMS storage: SIM card Preferred mode can be user-defined. - GPRS data downlink transfer: max. 85.6 kbps (see Table 3) - GPRS data uplink transfer: max. 42.8 kbps (see Table 3) - Coding scheme: CS-1, CS-2, CS-3 and CS-4 - GNS-MC35i Terminal supports the two protocols PAP (Password Authentication Protocol) and CHAP (Challenge DATA GPRS: Handshake Authentication Protocol) commonly used for PPP connections. - Support of Packet Switched Broadcast Control Channel (PBCCH) allows you to benefit from enhanced GPRS performance when offered by the network operators. - CSD transmission rates: 2.4, 4.8, 9.6, 14.4 kbps, DATA CSD: nontransparent, V.110 - Unstructured Supplementary Services Data (USSD) support FAX Group 3: Class 1, Class 2 - RS-232 interface, bi-directional bus for AT commands and data Serial interface (both - Multiplex ability according to GSM 07.10 Multiplexer protocol GNS-MC35iT, - Baud rates from 300bps to 230.400 bps GNS-MC35iU models) - Autobauding supports baud rates: 1.200, 2.400, 4.800, 9.600, 19.200, 38.400, 57.600, 115.200 and 230.400 bps 4

Serial interface (only GNS-MC35iU terminal) Supported SIM card Phonebook management Reset of terminal Firmware upgrade Real time clock Environmental Size Weight - Supports RTS/CTS hardware handshake and software XON/XOFF flow control. USB 2.0 interface, bi-directional bus for AT commands and data - Baud rates from 300bps to 230.400 bps - Autobauding supports baud rates: 1.200, 2.400, 4.800, 9.600, 19.200, 38.400, 57.600, 115.200 and 230.400 bps - Supports RTS/CTS hardware handshake and software XON/XOFF flow control. 3V Supported phonebook types: SM, FD, LD, MC, RC, ON, ME Reset via AT command or Power Down Signal Upgradable via serial interface or SIM interface. Implemented (clock frequency 32.768kHz) Temperature: - Normal operation: -20 C to +55 C - Humidity: max. 80 % relative humidity 65x74x33 mm (approx.) 130g Table 2. Coding schemes and maximum data rates Coding 1 Timeslot 2 Timeslots 4 Timeslots scheme CS-1: 9.05 kbps 18.1 kbps 36.2 kbps CS-2: 13.4 kbps 26.8 kbps 53.6 kbps CS-3: 15.6 kbps 31.2 kbps 62.4 kbps CS-4: 21.4 kbps 42.8 kbps 85.6 kbps 3 Electrical and environmental characteristics Table 3. Absolute maximum ratings Parameter Port/Description Min Max Units Supply voltage PLUS -40 28 V Input voltage for on/off Control lines /IGT_IN, PD_IN -28 28 V RS232 input voltage /TXD, /DTR, /RTS -28 +28 V range /RXD, /CTS, /DSR, /DCD, /RING -0.3 +5.3 V Immunity against discharge of static electricity Protection Class all connectors (lines) -8 +8 kv IP40 (avoid exposing GNS-MC35i Terminal to liquid or moisture, for example do not use it in a shower or bath) IP40 5

Table 4. Operating conditions Paramenter Min Type Max Units Ambient temperature -20 25 55 C 7.6 lowest voltage Supply voltage PLUS measured at (minimum peak) incl. 12 28 V (6-pole) western jack plug (1 to 6) all ripple and drops Table 5. Power supply characteristics Parameter description Conditions Min Type Max Units Average supply current (average time 3 min.) @8V 480 550 ma Power Down mode SLEEP mode (GSM/GPRS) NET Searching mode (NO NET) IDLE mode (GSM/GPRS) GSM TALK mode GPRS DATA mode(1 Tx, 4 RX) Peak supply current (during 577µs transmission slot every 4.6ms) Power control level for Pout max @12 700 800 @28 1750 1850 @8 45 ma @12 30 @28 17 @8 70 ma @12 50 @28 30 @8 60 ma @12 45 @28 25 @8 270 560 ma @12 170 33 @28 72 125 @8 290 570 ma @12 180 330 @28 77 125 @8 1.7 3.2 A @12 1.2 1.4 @28 0.7 1.2 After this time switched off Allowed powerfail time without terminal the Terminal reset or power down will be reset or 1 ms Allowed rise time of supply voltage 0% to 100% 20 ms 1) Typical values measured with antenna impedance = 50 Ohm (return loss >20dB) Maximum values measured with mismatched antenna 6

Table 6. On/Off control lines characteristics Parameter description Conditions Min Type Max Units Input voltage /IGT_IN, PD_IN, /DTR active high 5 28 V Active low -28 2 V Input resistance of /IGT_IN, PD_IN 94 kohm Input resistance of /DTR 4 6 8 kohm Duration of active high /IGT_IN, /DTR 200 ms Duration of active high PD_IN 3.5 s Duration passive (low) of /IGT_IN, /DTR before restart after power down 1 s Table 7. RS232 Interface characteristics Parameter description Conditions Min Type Max Units Transmitter Output Voltage for /RXD, /CTS, /DSR, /DCD, /RING @ 5kOhm load ±5 ±6 ±7 V Transmitter Output Resistance /RXD, /CTS, /DSR, /DCD, /RING 770 Ohm Receiver Input Resistance /TXD, /RTS, /DTR 4 6 8 kohm Input Hysteresis 0.2 0.5 1 V Input Threshold Low 1 1.8 V Input Threshold High 2.4 3 V Baud rate Autobauding 4.8 230.4 kbps Fixed rate 0.3 230.4 Kbps 4 Operating modes Table 9. Operating modes of the GNS-MC35iT, GNS-MC35iU Mode Normal operation SLEEP GSM IDLE GSM TALK Function Various power saving modes set by AT+CFUN command. Firmware is active to minimum extent. If the Terminal was registered to the GSM network in IDLE mode, it remains registered in SLEEP mode. Power saving can be chosen at different levels. The NON-CYCLIC SLEEP mode (AT+CFUN=0) disables the AT interface. The CYCLIC SLEEP mode AT+CFUN=5, 6, 7 and 8 alternatively activate and deactivate the AT interface to allow permanent access to all AT commands. Firmware is active. Once registered to the GSM network, paging with BTS is carried out. The Terminal is ready to send and receive. Connection between two subscribers is in progress. Power consumption depends on network coverage individual settings, such as DTX off/on, FR/EFR/HR, 7

Power Down GPRS IDLE GPRS DATA hopping sequences, antenna. Module is ready for GPRS data transfer, but no data is currently sent or received. Power consumption depends on network settings and GPRS configuration (e.g. DRX settings) GPRS data transfer in progress. Power consumption depends on network settings (e.g. power control level), uplink / downlink data rates and GPRS configuration (e.g. used multislot settings). Operating voltage applied. Firmware is not active. The RS-232 interface is not accessible. 5 Power supply The power supply of the GNS-MC35i Terminal has to be a single voltage source of 8V...28V providing a peak current (pulsed 577ms at T=4.615ms) of about 1.2A at 12V during the active transmission. The uplink burst causes strong ripple (drop) on the power lines. The drop voltage should not exceed 1V, but the absolute minimum voltage during drops must be >8V. The terminal is protected from supply voltage reverse. Figure 1: Female 6-pole Western plug for power supply, ignition, power down Table 10: Female 6-pole Western plug for power supply, ignition, power down Pin Signal name Use Parameters 1 PLUS Power supply 8V. 28V DC, 2 free 3 PD_IN Signal for power down mode 4 IGT_IN Ignition *) 5 free 6 GND Ground 0V 5V must be applied to this input for more than 3.5s to switch the terminal off. 2V must be applied for normal operation 5V applied to ignition input for more than 200ms switches the terminal on *) The ignition is activated only by a rising edge. The rise time is <20ms. The IGT_IN signal switches the terminal on (it changes from power down state to the net searching state). 8

Terminal GNS-MC35iU can be powered from the USB interface. If no additional power supply is used, in case of powering from the USB interface, then power line of the USB interface can be overloaded at some conditions. If this occurs then terminal will switch off due to insufficient power. After power will be restored terminal will switch on immediately. This can lead to unstable terminal functioning. 6 Power on/off control In the event of software hang-ups etc. the GNS-MC35i Terminal can be switched off by applying a voltage >5V to pin 3 (PD_IN) for more than 3.5s. The PD_IN signal switches the terminal off. All internal supply voltages are off, except for the power down voltage, which still feeds the real-time clock (RTC). To switch terminal on you have two options: Activate the ignition pin (IGT_IN pin 4) or switch on the RS-232 /DTR line, during PD_IN not active (pin 3 voltage <2V). - For all other operating modes the PD_IN signal must be low (<2V). - When the GNS-MC35i Terminal is switched off or enters the Power Down mode, e.g. after you have issued the AT^SMSO command or activated the PD_IN signal, all RS-232 interface lines are undefined during internal power shutdown process. This may cause undefined characters that can be ignored. - In order to properly shut down the GNS-MC35i Terminal be sure to wait 10s after sending AT^SMSO before switching off the power supply at pin PLUS. This time is needed for the module to safely log off from the network and finish saving to the internal memory. Caution: Use the PD_IN pin only when terminal is not responding for more than 5 seconds. Pulling the PD_IN pin causes the loss of all information stored in the volatile memory since power is cut off immediately. Therefore, this procedure is intended only for use in case of emergency, e.g. if GNS-MC35i Terminal fails to shut down properly. In the case of using USB bus connection for the GNS-MC35iU terminal it will be switched on by USB emulated signal /DTR. This signal acts like /DTR signal of RS232 interface. In additional GNS-MC35iU terminal will switch power on automatically (it changes from power down state to the net searching state) when USB plug connected to the terminal 7 RS232 interface Via RS-232 interface, the host controller controls the GNS-MC35i Terminal and transports data. Table 11: 9-pole D-Sub (female) RS-232 Pin Signal name I/O Function 1 /DCD O Data Carrier Detected 2 /RXD O Receive data 3 /TXD I Transmit data 4 /DTR I Data Terminal Ready Attention: The ignition of GNS-MC35i Terminal is activated via a rising edge of high potential (+5 +15 V) 5 GND 6 /DSR O Data set ready 7 /RTS I Request to send 8 /CTS O Clear to send 9

9 /RI O Ring indication GNS-MC35iT and GNS-MC35iU terminals are designed for use as a DCE. Based on the conventions for DCE-DTE connections it communicates with the customer application (DTE) using the following signals: - Port TxD @ application sends data to TXD of GNS-MC35i Terminal - Port RxD @ application receives data from RXD of GNS-MC35i Terminal The RS-232 interface is configured for 8 data bits, no parity and 1 stop bit, and can be operated at bit rates from 300bps to 115kbps. Autobauding supports bit rates from 4.8kbps to 115kbps. Hardware handshake using the /RTS and /CTS signals and XON/XOFF software flow control are supported. In addition, the modem control signals /DTR (polled once per second by internal firmware), /DSR, /DCD and /RING are available. The modem control signal RING (Ring Indication) can be used to indicate, to the cellular device application, that a call or Unsolicited Result Code (URC) is received. There are different modes of operation, which can be set with AT commands. 8 USB interface USB interface is realized in GNS-MC35iU terminal only and fully comply to USB 2.0 specification. GNS-MC35iU uses B receptacles plug for connection to PC. During interaction via USB interface, control signals of RS232 interface (like /DTR, /CTS, /DSR etc.) are also used. USB interface control logic fully corresponds to RS232 control logic, include ON/OFF control described in part 6 of this document. The USB host is responsible for supplying, across the USB power line for supplying power to the terminal s USB interface. But in some cases GNS-MC35iU terminal can consume more than 500mA from USB power line and there are no protection for overconsuming. To protect USB host from overconsuming one need to use power supply connected to the western 6 pole plug jack. At most cases overconsumption occurs when GSM signal is bad. Table 12: USB connector pins assignment Contact Signal name 1 VBUS 2 D- 3 D+ 4 GND Shell Shield 9 Coding of the status LED A green LED displays the operating status of the terminal: Operating status Power down Not registered to net (missing SIM, PIN, net) Standby (registered to the net) Sleep mode (Power save mode, registered to the net) Talk mode, GPRS data LED State Off Fast blinking Slow flash (75ms ON/ 3s OFF) off on 10