Product Specification for SAB-S-MODBUS

Similar documents
SAB-QS Quick Start November 9, SAB-QS Quick Start SAB-QS TRANSDUCERS 1 X4. Figure 1: SAB-QS Connector and Jumper Placement

Vorne Industries. Model 77/232 Serial Input Numeric 3" Display User's Manual

Product Specification for Transducer Display Model TDD2

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL

Getting Started with your D3000M Series Module

Product Specification and User Manual for Transducer Display Model TDD2

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

Product Specification for CANbus to DeviceNet Transducer Gateway

RS485 MODBUS Module 6RO

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

Manual 601: : USB/RS232. Specifications. Contents. Options

Breadboard & Digital Input/Output Modules

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

icex-cmtm General specs and Installation guide

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

RS485 MODBUS Module 8AO

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

4511 MODBUS RTU. Configuration Manual. HART transparent driver. No. 9107MCM102(1739) For 4511 devices from ser. no:

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

KTA-250 Anemometer Alarm Card

A36D/TPSD DNP 3.0 & Modbus SCADA INTERFACE

1. Overview Technical Specifications Applications Pin Description Connection Diagram of RS 485 / 422 Converter...

EAM 58 B / C - 63 A / D / E BIT PARALLEL - SSI

LAUREL ELECTRONICS, INC.

MODBUS Network Communication

MHAD 50 - HDmag. Features

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

Product Specification and User Manual for Transducer Display Model TDD2

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)

melabs Serial LCD Firmware Version 1.1 3/5/07

SSI-1016H Specifications and Operation Manual

RS 485 Mini Modbus 1AO

RS485 MODBUS Module 8I8O

MRUC-20 Modul-R CAN Bus Network

Golander Peristaltic Pump MODBUS Communication Instruction

mifare ID Reader with Selectable Outputs Data Sheet

SeaI/O User Manual. PO Box 830 Liberty, SC

Table of Contents 1 ABOUT THIS GUIDE CONTACT INFORMATION ANTENNA INSTALLATION... 4

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

DNP 3.0 & Modbus SCADA INTERFACE INSTRUCTIONS FOR 205T BASED SYSTEMS

Vorne Industries. 2000S Series Serial Input Alphanumeric Display User's Manual

Product Specification and User Manual for Transducer Display Model TDD2

Digital Frequency Divider INSTRUCTION MANUAL CONTENTS. 1. Working Principle Installation Setting Up Technical Data 4.

RS485 MODBUS Module 16I-M

MC CO MODBUS ADDRESSABLE SENSOR

Real Time Clock with Temperature Sensor and RS485/Modbus Comunications

EGW1-IA3-MB User s Manual

BQ & BQ370-01N MODBUS ANALOG INPUT DEVICE USER MANUAL

The I-7530A-MR Modbus RTU to CAN Converter

SDM-8I8O. Expansion Module 8 digital inputs, 8 digital outputs. Manufactured for

GE Fanuc IC694ALG221. Rx3i PacSystem

NetBiter I/O Extender User Manual

Carbon Monoxide Sensor - ModBus

Message Runner KP3H. Text Display. Small messages on your machine. Compact DIN 36 x 72 profile. Green and orange character display.

Installation and Operation Manual. INTEGRA BTU Meter System

Wireless Transducer MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

Tango. alpha nea. Thermometers and controllers with digital communication - Series AM

USER S MANUAL VER.2. C76- MULTIFUNCTION CNC BOARD Rev. 1.4

SmartMod DC Digital Input Module HE359DIM610 12/24VDC Negative Logic

Modbus Communications Board

OEM Proximity Reader with Keypad Manual REV1

Communicative controller for VAV systems

CuteLine AIN8 UI - Voltage Current. Manual

ADDJOG User Guide 7/30/10. Overview

LPG STM 94442A User s Manual

About this Manual. Description

Hardware Manual CNC760

R3-NE1 ETHERNET INTERFACE MODULE MODEL. Remote I/O R3 Series. (Modbus/TCP)

Small distributed I/O module

Vorne Industries. 87/415 Rate Monitor Display User's Manual Industrial Drive Itasca, IL (630) Telefax (630)

BLD04A Brushless DC Motor Driver

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

MOTION COORDINATOR MC403 / MC403-Z Quick Connection Guide

PRELIMINARY EAMH 58 B / C - 63 A / D / E BIT PARALLEL - SSI SOLID SHAFT MULTITURN ABSOLUTE ENCODER ORDERING CODE BIT PARALLEL

Easy Arc Integration into a Simatic S7-300 Process Control System

Installation and Operating Instructions

Flex Series User Guide

EAZY-CAL LVC-4000 LVDT Signal Conditioner User Manual

BARIX IO12. I/O to RS-485 Modbus converter for commercial interfacing, control and home automation applications PRO D UCT MANUAL. Version: 2.

Signal Isolators & Conditioners

Signal Isolators & Conditioners

INTRINSICALLY SAFE DUPLEXER PROTECTION. ELECTRONICS, INC Vulcan Road Apopka, Florida MOTOR INSTRUCTION MANUAL

FCU-MULTI Modbus Fan Coil Unit Controller

Overview. The DINIO-RS485 has five primary functions:

DEV-1 HamStack Development Board

DL-10. User Manual. RS-485 Remote Temperature and Humidity. English Ver. 1.0, Jul. 2017

MODEL: R2K-1 SEN TRONIC AG. R2K Series

MOTION COORDINATOR MC405 Quick Connection Guide

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

TMC428 Evaluation Kit V2.0 Manual English

EasyIO FC20 User Reference v1.3. EasyIO FC 20 DDC User Reference V1.3

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

Series 957SSI Brik. Linear Displacement Transducer. Installation Manual. 957SSI Brik ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE...

User s Manual Hub444. Motion Control Network Hub

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND

Copyright Extract from Conditions of Sale Safety Warning

4511 MODBUS RTU. Configuration Manual. Pulse isolator. No. 9202MCM101(1707) For 4511 devices from ser. no:

Transcription:

SAB-S-MODBUS May 9, 2011 Product Specification for SAB-S-MODBUS The SAB-S-MODBUS is a two-channel module that measures single or multiple magnet transducer position and returns this information to a host computer via a serial interface using the Modbus ASCII or RTU protocol over a RS232 or RS485 port. Communication setup is controlled via dip-switch settings and sensor interface configuration is controlled via Modbus registers. Features Two channels of 32 bit magnetostrictive transducer position Supports Start/Stop, PWM, and SSI sensor communication protocols Up to 16 magnets per transducer when used with Start/Stop output sensors Modbus ASCII or RTU operation, switch selectable Compatible with any Start/Stop, PWM, or SSI output magnetostrictive transducer Also compatible with other SSI output sensors such as absolute encoders Convenient removable screw terminals for all connections Serial interface operates with RS232 or RS485 2400, 9600, 19200 and 57600 Baud, 8 Bits, No Parity, 1 Stop bit Blinking red LED indicates processor operation LED and digital output for each channel indicates sensor status EEPROM for nonvolatile storage of setup parameters +24 VDC power is distributed to the transducers Specifications 2 Channels of Start/Stop, PWM, or SSI magnetostrictive transducer measurement with RS-422 levels 0.002 inch resolution in multi-magnet mode Up to 16 magnets per sensor when using a Start/Stop output sensor Update rate: 3 milliseconds RS485, RS232 at 2400, 9600, 19200 and 57600 Baud, 8 Bits, No Parity, 1 Stop bit 28 MHz 87C520 processor with 1K local ram Sixty-four words of EEPROM storage Two 5V DC inputs can be viewed Two relay contact outputs indicate transducer status Power: 24 VDC at < 300 milliamps Physical Size: 4.88 x 4.00 x 1.75 inches (occupies 1.75 inches of DIN rail space) Rapid Controls Inc. Box 8390 Rapid City, SD 57709 Phone: 605-348-7688 Fax: 605-341-5496 http://www.rapidcontrols.com/ email: info@rapidcontrols.com

SAB-S-MODBUS May 9, 2011 Contents Operation...1 Host Communications...1 MODBUS overview...1 Readable Coils Supported...1 Readable Discrete Inputs Supported...1 Readable Registers Supported...1 Writeable Coils Supported...3 Writeable Registers Supported...3 MODBUS command details...4 Read Coil Status...4 Read Holding Registers...4 Force Single Coil...5 Preset Registers...5 Setup...6 Offline Test mode...8 Jumpers...8 Jumper X1...8 Jumper X2...8 Jumper X3...8 Jumper X4...8 Jumper X5...8 Jumper X6...8 Connectors...9 Connector J1...9 Connector J2...9 Connector J3...10 Connector J4...10 Power Consumption...10 Connections...11 Enclosure...12 Rapid Controls Inc. Box 8390 Rapid City, SD 57709 Phone: 605-348-7688 Fax: 605-341-5496 http://www.rapidcontrols.com/ email: info@rapidcontrols.com

Operation At power on, the board immediately retrieves the setup values from the EEPROM memory and begins operation. Operation consists of interrogating both transducers during each 3ms update period and updating the position information stored in the data registers. The board allows host communications at any time. Host Communications The board communicates to a host computer via RS232 or RS485 using a subset of the MODBUS protocol. ASCII or RTU mode is selected by via a dipswitch. Note that all examples are given as ASCII mode. See the Modbus Protocol Reference Guide (available at www.modbus.org) for more information on the MODBUS protocol. MODBUS overview Note: When using Modbus queries, coils, registers, and input addresses start at 0. Thus the address for coil 1 is 0. Readable Coils Supported 1 Status of Channel A: On = OK, Off = Failed 2 Status of Channel B: On = OK, Off = Failed 3 State of Discrete Output 1 4 State of Discrete Output 2 5 State of Discrete Output 3 6 State of Discrete Output 4 7 State of Discrete Output 5 8 State of Discrete Output 6 Readable Discrete Inputs Supported 1 Discrete input 1 2 Discrete input 2 Readable Registers Supported 1 Channel A, number of magnets expected (Start/Stop only) 2 Channel B, number of magnets expected (Start/Stop only) 3-32 Reserved 33 Channel A, Magnet 1 High Word Of Position (Read Only) 34 Channel A, Magnet 1 Low Word Of Position (Read Only) 35 Channel A, Magnet 2 High Word Of Position (Read Only) 36 Channel A, Magnet 2 Low Word Of Position (Read Only) 37 Channel A, Magnet 3 High Word Of Position (Read Only) 38 Channel A, Magnet 3 Low Word Of Position (Read Only) 39 Channel A, Magnet 4 High Word Of Position (Read Only) 40 Channel A, Magnet 4 Low Word Of Position (Read Only) 41 Channel A, Magnet 5 High Word Of Position (Read Only) 42 Channel A, Magnet 5 Low Word Of Position (Read Only) 43 Channel A, Magnet 6 High Word Of Position (Read Only) 44 Channel A, Magnet 6 Low Word Of Position (Read Only) 45 Channel A, Magnet 7 High Word Of Position (Read Only) 46 Channel A, Magnet 7 Low Word Of Position (Read Only) 47 Channel A, Magnet 8 High Word Of Position (Read Only) 48 Channel A, Magnet 8 Low Word Of Position (Read Only) 49 Channel A, Magnet 9 High Word Of Position (Read Only)

50 Channel A, Magnet 9 Low Word Of Position (Read Only) 51 Channel A, Magnet 10 High Word Of Position (Read Only) 52 Channel A, Magnet 10 Low Word Of Position (Read Only) 53 Channel A, Magnet 11 High Word Of Position (Read Only) 54 Channel A, Magnet 11 Low Word Of Position (Read Only) 55 Channel A, Magnet 12 High Word Of Position (Read Only) 56 Channel A, Magnet 12 Low Word Of Position (Read Only) 57 Channel A, Magnet 13 High Word Of Position (Read Only) 58 Channel A, Magnet 13 Low Word Of Position (Read Only) 59 Channel A, Magnet 14 High Word Of Position (Read Only) 60 Channel A, Magnet 14 Low Word Of Position (Read Only) 61 Channel A, Magnet 15 High Word Of Position (Read Only) 62 Channel A, Magnet 15 Low Word Of Position (Read Only) 63 Channel A, Magnet 16 High Word of Position (Read Only) 64 Channel A, Magnet 16 Low Word of Position (Read Only) 64 96 Reserved 97 Channel B, Magnet 1 High Word Of Position (Read Only) 98 Channel B, Magnet 1 Low Word Of Position (Read Only) 99 Channel B, Magnet 2 High Word Of Position (Read Only) 100 Channel B, Magnet 2 Low Word Of Position (Read Only) 101 Channel B, Magnet 3 High Word Of Position (Read Only) 102 Channel B, Magnet 3 Low Word Of Position (Read Only) 103 Channel B, Magnet 4 High Word Of Position (Read Only) 104 Channel B, Magnet 4 Low Word Of Position (Read Only) 105 Channel B, Magnet 5 High Word Of Position (Read Only) 106 Channel B, Magnet 5 Low Word Of Position (Read Only) 107 Channel B, Magnet 6 High Word Of Position (Read Only) 108 Channel B, Magnet 6 Low Word Of Position (Read Only) 109 Channel B, Magnet 7 High Word Of Position (Read Only) 110 Channel B, Magnet 7 Low Word Of Position (Read Only) 111 Channel B, Magnet 8 High Word Of Position (Read Only) 112 Channel B, Magnet 8 Low Word Of Position (Read Only) 113 Channel B, Magnet 9 High Word Of Position (Read Only) 114 Channel B, Magnet 9 Low Word Of Position (Read Only) 115 Channel B, Magnet 10 High Word Of Position (Read Only) 116 Channel B, Magnet 10 Low Word Of Position (Read Only) 117 Channel B, Magnet 11 High Word Of Position (Read Only) 118 Channel B, Magnet 11 Low Word Of Position (Read Only) 119 Channel B, Magnet 12 High Word Of Position (Read Only) 120 Channel B, Magnet 12 Low Word Of Position (Read Only) 121 Channel B, Magnet 13 High Word Of Position (Read Only) 122 Channel B, Magnet 13 Low Word Of Position (Read Only) 123 Channel B, Magnet 14 High Word Of Position (Read Only) 124 Channel B, Magnet 14 Low Word Of Position (Read Only) 125 Channel B, Magnet 15 High Word Of Position (Read Only) 126 Channel B, Magnet 15 Low Word Of Position (Read Only) 127 Channel B, Magnet 16 High Word Of Position (Read Only) 128 Channel B, Magnet 16 Low Word Of Position (Read Only) Writeable Coils Supported 3 State of Discrete Output 1 4 State of Discrete Output 2

5 State of Discrete Output 3 6 State of Discrete Output 4 7 State of Discrete Output 5 8 State of Discrete Output 6 Writeable Registers Supported 1 Channel A, Number of magnets expected (Start/Stop only) 2 Channel B, Number of magnets expected (Start/Stop only)

MODBUS command details Note: In the following, [CR] refers to a Carriage Return/Line Feed Pair. The following commands are shown in ASCII format. For more information on RTU mode, please see the Modbus Protocol Reference Guide (available at www.modbus.org). Read Coil Status :XX0100YY00ZZCS[CR] YY is the hexadecimal starting address (first coil) ZZ is the hexadecimal number of coils to read Requests the status of a set of coils. Returns: :XX01BBZZ 0 ZZ x CS[CR] BB is the data byte count ZZ 0 through ZZ x are the returned coil values. Coils are returned 1 bit per coil. The first coil requested is the LSB of the first data byte. If the number of coils is not a multiple of 8, the remainder of the byte is padded with 0s. Read Discrete Inputs :XX0200YY00ZZCS[CR] YY is the hexadecimal starting address (first register) ZZ is the hexadecimal number of registers to read Requests the binary contents of a set of discrete inputs Returns: :XX02BBZZ0 ZZxCS[CR] + BB is the data byte count ZZ 0 through ZZ x are the returned input coil values. Coils are returned 1 bit per coil. The first coil requested is the LSB of the first data byte. If the number of coils is not a multiple of 8, the remainder of the byte is padded with 0s. Read Holding Registers :XX0300YY00ZZCS[CR] YY is the hexadecimal starting address (first register) ZZ is the hexadecimal number of registers to read Requests the binary contents of a set of registers Returns: :XX03BBZZ0 ZZxCS[CR] BB is the data byte count ZZ 0 through ZZ x are the returned register values. Registers are returned as two bytes, MSB first.

Force Single Coil :XX0500YYZZ00CS[CR] YY is the hexadecimal address of the coil ZZ is set to FF to force the coil ON; 00 to force the coil OFF. Forces (sets) a single coil to either ON or OFF. Returns: An echo of the query. Preset Registers :XX0600YYZZ 0 ZZ 1 CS[CR] YY is the hexadecimal address ZZ 0 Hi byte of the value ZZ 1 Low byte if the value. Registers are set as two bytes, MSB first. Writes the binary contents of a set of registers Returns: :XX03BBZZ 0 ZZ 1 CS[CR] YY is the hexadecimal addressing ZZ 0 Hi byte of the value ZZ1 Low byte if the value. Registers are set as two bytes, MSB first.

Setup The SAB-S-MODBUS board ships from the factory with default values installed. The default setup is as follows: ChA expected Magnets: 1 ChB expected Magnets: 1 The number of expected magnets is written using the preset holding registers command for registers 1 and 2. The values of these registers (1 and 2) are stored in EEPROM when written and will remain after the power is cycled. The number of magnets setting is only valid when using a Start/Stop sensor; PWM sensor support is limited to one magnet only. Other values are set via the dipswitches. The following items can be changed: Baud Rate (8 bits, No Parity, 1 Stop bit) Switches 1 and 2 define the baud rate. Baud Rate Switch 1 Switch 2 2400 bps OFF OFF 9600 bps ON OFF 19200 bps OFF ON 57600 bps ON ON Protocol Mode Switch 3 selects between ASCII and RTU protocol modes. Protocol Mode Switch 3 ASCII OFF RTU ON Offline Test Mode Switch 4 activates the Offline Test mode when it is on. See Offline Test Mode section. Slave ID Switches 5-8 select the Slave ID of the SAB-S-MODBUS. Slave ID Switch 5 Switch 6 Switch 7 Switch 8 1 OFF OFF OFF OFF 2 ON OFF OFF OFF 3 OFF ON OFF OFF 4 ON ON OFF OFF 5 OFF OFF ON OFF 6 ON OFF ON OFF 7 OFF ON ON OFF 8 ON ON ON OFF 9 OFF OFF OFF ON 10 ON OFF OFF ON 11 OFF ON OFF ON 12 ON ON OFF ON 13 OFF OFF ON ON 14 ON OFF ON ON 15 OFF ON ON ON 16 ON ON ON ON

Offline Test mode If dipswitch 4 is ON when power is applied the SAB-S-MODBUS board enters the Offline Test mode of operation. This mode can be used to see the magnet count for each channel. Connect the board to a serial terminal or PC with terminal emulator software. When the board enters the Offline Test mode the current magnet positions will be printed. During Offline Test mode, the number of expected magnets can be changed. Send the number zero ( 0 ) to change the number of magnets expected for channel A. Send the number one ( 1 ) to change the number of magnets expected for channel B. User Configurable Jumpers Jumper X1 1-3 This jumper selects the serial communications receive format. X1 1-2 RS485 X1 2-3 RS232 Jumper X1 4-6 This jumper selects the sense of the DC input 1. Install 4-5 for active low input, 5-6 for active high input. Jumper X1 7-9 This jumper selects the sense of the DC input 2. Install 7-8 for active low input, 8-9 for active high input. Jumper X2 This jumper connects RS485 line termination resistors. Install 9-10 and 11-12 for the last board in a series of RS485 configured boards to provide 120 Ohm line termination and 1k Ohm biasing resistors. Jumper X3-5 These jumpers are factory set. Models supporting Start/Stop and PWM sensors have X3 & X5 set 1-2 & 3-5. X4 and X6 set 1-2. Models supporting SSI sensors have X3 & X5 set 1-2. X4 and X6 set to 2-3.

Connectors Connector JP1 J1 1 J1 2 J1 3 J1 4 J1 5 J1 6 J1 7 J1 8 J1 9 J1 10 Logic Ground RS232 Receive from host RS232 Transmit to host RS485 - (RS485-A) RS485 +(RS485-B) DC input 1. An open-collector output or 5 volt logic can be used to pull this line low. DC input 2. An open-collector output or 5 volt logic can be used to pull this line low. Status common for channel A and channel B relay outputs. Channel A transducer status normally open relay contact. Closed and connected to J1-8 when a good transducer is connected. Channel B transducer status normally open relay contact. Closed and connected to J1-8 when a good transducer is connected. Connector JP2 All signals are 5V TTL level with 20 ma current limit. Each output is available in it s true and complemented form. J2 1 Discrete output 1 J2 2 Discrete output 1# J2 3 Discrete output 2 J2 4 Discrete output 2# J2 5 Discrete output 3 J2 6 Discrete output 3# J2 7 Logic ground J2 8 Discrete output 4 J2 9 Discrete output 4# J2 10 Discrete output 5 J2 11 Discrete output 5# J2 12 Discrete output 6 J2 13 Discrete output 6# J2 14 Logic ground

Connector JP3 Transducer connector J3 1 ChA Interrogate + to the transducer (YELLOW) J3 2 ChA Interrogate - to the transducer (GREEN) J3 3 ChA Gate + from the transducer (PINK) J3 4 ChA Gate - from the transducer (GRAY) J3 5 + Power to the transducer (RED) J3 6 Ground (WHITE & SHIELD) J3 7 - Power to the transducer (BLUE) J3 8 ChB Interrogate + to the transducer (YELLOW) J3 9 ChB Interrogate - to the transducer (GREEN) J3 10 ChB Gate + from the transducer (PINK) J3 11 ChB Gate - from the transducer (GRAY) J3 12 + Power to the transducer (RED) J3 13 Ground (WHITE & SHIELD) J3 14 - Power to the transducer (BLUE) Connector JP4 The board is powered via J4; the board can operate on any DC voltage from 7.5V to 26VDC. However, the voltage input on J4-1 is also passed along to the transducers via J3-5 and J-3-12. When using transducers requiring +24V apply +24V to J4-1, ground to J4-2 and do not apply any voltage at J4-3. For transducers requiring +/- 15V apply +15V to J4-1, ground J4-2 and apply 15V to J4-3. J4 1 J4 2 J4 3 +7.5 to +26 VDC input the board and the transducers (typically +24VDC) Power supply and signal ground -15 VDC input to the board (for sensors requiring -15V only) Power Consumption The board consumes approximately 100 milliamps of the + input voltage supplied to J4-1 for it s own operation. Each transducer attached requires approximately 100 milliamps of the + input voltage for a total of 300 milliamps. The board does not require the input voltage at J4-3 but passes it along to the transducer.

Connections The board and the connectors are oriented as shown here. There is a direct connection form J4-1 to J3-5 and 12. There is also a direct connection from J4-3 to J3-7 and 14. Ground is common to J4-2, J3-6, J3-13, J2-7, J2-14 and J1-1.

Enclosure The SAB-S-MODBUS comes mounted in a DIN rail enclosure, containing one or two SAB-S- MODBUS boards. The enclosure is 4.64 inches deep x 5.31 deep x 1.77 wide, and uses 1.8 inches or DIN rail space. This configuration can provide up to four channels of magnetostrictive transducer input per enclosure.