Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Electronic Motor DRC Functional Safety

Similar documents
* _1216* Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Electronic Motor DRC..

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVITRAC MC07B Functional Safety

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVITRAC MC07B Functional Safety

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety

Manual. Decentralized Extra-Low Voltage Servo Drive CMP ELVCD Functional Safety * _0717*

Manual. MOVIMOT MM..D Functional Safety (including field distributor) * _0516*

Addendum to the Manual

Drive Technology \ Drive Automation \ System Integration \ Services. Quick Start Guide. MOVIMOT MM..D With DRS/DRE/DRP AC Motor

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVIPRO Functional Safety

Addendum to the Operating Instructions

Manual. Decentralized Drive and Application Controller MOVIPRO ADC Functional Safety

Addendum to the Operating Instructions

Manual. Decentralized Drive Control MOVIFIT FDC-SNI Connection to PROFIBUS/DeviceNet with UFF41B Fieldbus Gateway

Operating Instructions MOVISAFE UCS.B Safety Modules

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVIFIT SNI Fieldbus Gateway UFF41B for MOVIGEAR SNI

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. CCU Universal Module Application Module

* _0318* Drive Technology \ Drive Automation \ System Integration \ Services. Manual. DFS21B PROFINET IO Fieldbus Interface with PROFIsafe

FSO Webnair FSO Safety Functions Module. ABB Group February 11, 2015 Slide 1

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVIFIT SNI UFF41B/UFR41B Fieldbus Gateway for MOVIGEAR SNI

Addendum to the System Manual. MOVIGEAR SNI Expanded Parameter Setting and Diagnostics with MOVITOOLS MotionStudio. Edition 01/ / EN

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

Options for ABB drives. User s manual Prevention of unexpected start-up (option +Q957) for ACS880-07/17/37 drives

Options for ABB drives. User s manual Emergency stop, stop category 1 (option +Q964) for ACS880-07/17/37 drives

Options for ABB drives. User s manual Prevention of unexpected start-up (option +Q950) for ACS880-07/17/37 drives

Options for ABB drives. User s manual Emergency stop, stop category 0 (option +Q951) for ACS880-07/17/37 drives

EN BU Functional Safety. Supplementary manual for series SK 500E

SMVector Additional I/O Module Installation and Operation Manual

Controller CMXH. Description STO. Safe Torque Off (STO) [ ]

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Manual. DFS21B PROFINET IO Fieldbus Interface with PROFIsafe (Safe Stop) Edition 10/ / EN

* _1118* Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Interface Adapter USM21A

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

ISO SINAMICS G110D FAQ

Revision. MOVIPRO with EtherNet/IP or Modbus TCP Fieldbus Interface * _1017*

Manual. Fieldbus Interface DFS11B PROFIBUS DP-V1 with PROFIsafe. Edition 09/ / EN

AS-i Safety Relay Output Module with Diagnostic Slave

SINAMICS SINAMICS G120. Frequency inverter with Control Units CU240E-2 CU240E-2 DP CU240E-2 F CU240E-2 DP-F. Function Manual Safety Integrated 07/2010

Operating Manual -ENGLISH- Page 1 KWG-ISO

PSR UC/ESAM4/3X1/1X2/B

Manual. MOVIDRIVE MDX61B Safety Module Option DCS21B/31B. Edition 03/ / EN

AS-i Safety Relay Output Module with Diagnostic Slave

Manual. MOVIDRIVE MDX60B / 61B Crane Control Application. Edition 01/ / EN

Resolver to Digital Expansion Board

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

EN BU Functional Safety. Supplementary manual for series SK 200E

Motor controller CMMS-AS-C4-3A-G2. Description. STO safety function (Safe Torque Off) b [ ]

to 12a Added Standard and Electrical requirements for UL table 1.1

* _1017* Drive Technology \ Drive Automation \ System Integration \ Services. Revision. MOVIPRO SDC With PROFINET Interface

Assembly and Operating Instructions Door Control

Welcome to the overview of ACS880 functional safety, FSO-11 Safety functions module.

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

DriveGuard. Safe-Off Option for PowerFlex 70 AC Drives. User Manual.

Revision. Decentralized Drive and Application Control MOVIPRO ADC with PROFINET interface * _1017*

Options for ABB drives. User s manual FPTC-01 thermistor protection module (option +L536) for ACS880 drives

PSR DC/ESP4/2X1/1X2

VARAN-INTERFACE VAC 012

SIL3 / PLe. Chapter 6 Safe Torque Off. Safe Torque Off 6-1

PowerFlex 700H AC Drive Safe Torque Off Option

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

MDM 011-Z1 Regen Resistor

Revision to Manual

Revision to the Operating Instructions

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

SMVector Additional I/O Module Installation and Operation Manual

Operating instructions AC010S Compact AS-i E-STOP safety module

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVITRAC B Simple Positioning Application Module

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

EDS94AYAB.;2G. L force Drives. Ä.;2Gä. Manual E94AYAB SM100. Safety module

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Documentation. Mains filter AX2090-NF50. Version: Date:

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVIAXIS Multi-Axis Servo Inverter MXR Regenerative Power Module

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Operating instructions. Speed monitor D / / 2014

Operating Instructions

User's Manual. english

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

Operating Instructions

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Operating instructions

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

SINAMICS G120 SINAMICS G120C

Manual. MOVIAXIS MX Multi-Axis Servo Inverter Virtual Encoder Technology Function. Edition 05/ / EN

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

SINAMICS Siemens Controlss

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

Operating Instructions

* _1216* Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVIPRO with EtherNet/IP or Modbus/TCP Fieldbus Interface

Firmware Manual - EC Series Drives

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Safety Technique. SAFEMASTER C Multifunction Safety Module BH 5910

Manual. Libraries MPLCTec..._MDX, MPLCTecVirtualEncoder for MOVI-PLC. Edition 07/ / EN

Product Information. ECN 1023 EQN 1035 Rotary Encoders with EnDat 2.2 for Safety-Related Applications

Welcome to the Safety functions training module for ACS880 cabinet-built industrial drives.

Options for ABB drives. User s manual FSE-31 pulse encoder interface module

Operating instructions Safety-monitoring module SE-304 C. 1. About this document. Content

Transcription:

Drive Technology \ Drive Automation \ System Integration \ Services Manual Electronic Motor DRC Functional Safety Edition 02/2012 19376812 / EN

SEW-EURODRIVE Driving the world

Contents Contents 1 General Information... 4 1.1 Use of this documentation... 4 1.2 Underlying standards... 4 1.3 Structure of the safety notes... 4 1.4 Rights to claim under limited warranty... 5 1.5 Exclusion of liability... 5 1.6 Content of the documentation... 5 1.7 Other applicable documentation... 5 1.8 Copyright... 5 1.9 Product names and trademarks... 5 2 Integrated Safety Technology... 6 2.1 Safe condition... 6 2.2 Safety concept... 6 2.3 Safety functions... 8 2.4 Restrictions... 10 3 Safety Conditions... 11 3.1 Approved devices... 11 3.2 Installation requirements... 12 3.3 External safety controller requirements... 14 3.4 Startup requirements... 16 3.5 Operational requirements... 16 4 Technical Data... 17 5 Appendix... 18 5.1 Unit variants with optional standard brake... 18 5.2 Connection variants... 20 5.3 Connection of an external safety relay for STO... 25 5.4 Connection of an external safety controller for STO... 29 Index... 33 Manual Functional Safety for DRC Electronic Motor 3

1 General Information Use of this documentation 1 General Information 1.1 Use of this documentation The documentation is an integral part of the product and contains important information on operation and service. The documentation is written for all employees who assemble, install, startup, and service this product. The documentation must be accessible and legible. Make sure that persons responsible for the system and its operation, as well as persons who work independently on the unit, have read through the documentation carefully and understood it. If you are unclear about any of the information in this documentation, or if you require further information, contact SEW-EURODRIVE. 1.2 Underlying standards The safety assessment of the unit is based on the following standards and safety classes: Underlying standards Safety class/underlying standard Performance level (PL) according to EN ISO 13849-1:2008 Safety Integrity Level (SIL) according to IEC 61800-5- 2:2007 1.3 Structure of the safety notes 1.3.1 Meaning of the signal words The following table shows the grading and meaning of the signal words for safety notes, notes on potential risks of damage to property, and other notes. Signal word Meaning Consequences if disregarded DANGER Imminent danger Severe or fatal injuries WARNING Possible dangerous situation Severe or fatal injuries CAUTION Possible dangerous situation Minor injuries NOTICE Possible damage to property Damage to the drive system or its environment INFORMATION Useful information or tip: Simplifies the handling of the drive system. 1.3.2 Structure of the section-related safety notes Section-related safety notes do not apply to a specific action, but to several actions pertaining to one subject. The used symbols indicate either a general or a specific hazard. This is the formal structure of a section-related safety note: SIGNAL WORD Type and source of danger. Possible consequence(s) if disregarded. Measure(s) to prevent the danger. 4 Manual Functional Safety for DRC Electronic Motor

General Information Rights to claim under limited warranty 1 1.3.3 Structure of the embedded safety notes Embedded safety notes are directly integrated in the instructions just before the description of the dangerous action. This is the formal structure of an embedded safety note: SIGNAL WORD Nature and source of hazard. Possible consequence(s) if disregarded. Measure(s) to prevent the danger. 1.4 Rights to claim under limited warranty A requirement of fault-free operation and fulfillment of any rights to claim under limited warranty is that you adhere to the information in the documentation. Read the documentation before you start working with the unit! 1.5 Exclusion of liability You must comply with the information contained in this documentation to ensure safe operation and to achieve the specified product characteristics and performance features. SEW-EURODRIVE assumes no liability for injury to persons or damage to equipment or property resulting from non-observance of these operating instructions. In such cases, any liability for defects is excluded. 1.6 Content of the documentation This document contains additional safety-related information and conditions for the operation in safety-related applications. 1.7 Other applicable documentation This document supplements the operating instructions and limits the application notes according to the following information. Use this document only together with the operating instructions. 1.8 Copyright 2011 SEW-EURODRIVE. All rights reserved. Unauthorized duplication, modification, distribution or any other use of the whole or any part of this documentation is strictly prohibited. 1.9 Product names and trademarks All brands and product names in this documentation are trademarks or registered trademarks of their respective titleholders. Manual Functional Safety for DRC Electronic Motor 5

2 Integrated Safety Technology Safe condition 2 Integrated Safety Technology The safety technology of the DRC drive unit described below has been developed and tested in accordance with the following safety requirements: SIL 3 according to IEC 61800-5-2:2007 PL e according to EN ISO 13849-1:2008 This was certified by TÜV Nord. Copies of the TÜV certificate and the corresponding report are available from SEW-EURODRIVE on request. 2.1 Safe condition For safety-related operation of DRC drive units, safe torque off is defined as safe condition (see STO safety function). The underlying safety concept is based on this definition. 2.2 Safety concept The DRC drive unit can be connected to an external safety controller or safety relay. This disconnects the safety-related STO input via a 2-pole 24 V switching signal when a connected control device (e.g. emergency stop button with latching function) is activated. This activates the STO function (safe disconnection) of the DRC drive unit. An internal, dual-channel structure with diagnostics (1oo2D) prevents the generation of pulse trains at the power output stage (IGBT) On the one hand, the internal supply voltage for controlling the upper and lower IGBTs is disconnected, and on the other hand the controlling pulse patterns are short-circuited. This means that the output stage can no longer supply power to the motor for generating torque. Instead of galvanic separation of the drive from the supply system by means of contactors or switches, the disconnection of the STO input described here safely prevents the control of the power semiconductors in the output stage. The rotary-field generation for the respective motor is deactivated even though the line voltage is still present. 6 Manual Functional Safety for DRC Electronic Motor

Integrated Safety Technology Safety concept 2 2.2.1 Schematic representation "Safety concept for DRC" The following figure shows a schematic representation of the safety concept for the DRC drive unit: HV SNT SNT 24V Safety [1] [2] [3] μc UZ+ [4] [5] M UZ- 2463070859 [1] Safety controller/safety relay external [2] Connection "STO+" [3] Connection "STO-" [4] Motor phase [5] Motor Manual Functional Safety for DRC Electronic Motor 7

2 Integrated Safety Technology Safety functions 2.3 Safety functions The following drive-related safety functions can be used: STO (safe torque off according to IEC 61800-5-2) through disconnection of the STO input. If the STO function is activated, the frequency inverter no longer supplies power to the motor for generating torque. This safety function corresponds to a non-controlled stop according to EN 60204-1, stop category 0. The STO input must be switched off by a suitable external safety controller or a suitable external safety relay. The following figure shows the STO function: v t 1 t 2463228171 v t t 1 Speed Time Time at which STO is triggered Disconnection range 8 Manual Functional Safety for DRC Electronic Motor

Integrated Safety Technology Safety functions 2 SS1(c) (Safe Stop 1, function variant c according to IEC 61800-5-2) through suitable external controller (e.g. safety relay with delayed switch-off). The following sequence is mandatory: Decelerate the drive using an appropriate brake ramp specified via setpoints. Disconnect the STO input (= triggering the STO function) after a specified safetyrelated time delay. This safety function corresponds to a controlled stop according to EN 602041, stop category 1. The following figure illustrates the SS1(c) function: v t 1 t t 2 t 2463226251 v t t 1 t 2 t Speed Time Point of time when brake ramp is initiated Point of time when STO is triggered Time between initiating the brake ramp and STO Safe time delay range Disconnection range Manual Functional Safety for DRC Electronic Motor 9

2 Integrated Safety Technology Restrictions 2.4 Restrictions WARNING The safety concept is only suitable for performing mechanical work on the system/machine components. If the STO signal is disconnected, the supply system voltage is still present at the DC link of the DRC. Severe or fatal injuries from electric shock. Before working on the electric part of the drive system, disconnect it from the supply system using an appropriate external disconnecting device and secure it against unintentional reconnection to the power supply. The standard brake that can optionally be integrated in DRC drive units is not safety-related and therefore not part of the safety functions mentioned above. If the brake controller and/or the motor brake fails, the drive can coast for much longer depending on the application (i.e. the friction and inertia of the system). In case of regenerative loads (e.g. lifting axes, declining conveying lines), the drive can even accelerate. This must be taken into account for a risk analysis of the system/machine. Additional safety measures might have to be implemented (e.g. safety brake system). The DRC drive unit cannot be used without an additional brake system for application-specific safety functions that require active deceleration (braking) of the dangerous movement. When using the SS1(c) function as described in chapter "Safety functions", the brake ramp of the drive is not monitored with respect to safety. In case of a fault, the drive might not be decelerated after the delay time, or it might be accelerated in the worst case. In this case, the STO function (see chapter "Safety functions") is only activated after the set time delay has elapsed. The resulting danger must be taken into account in the risk assessment of the system/machine. Additional safety measures might have to be implemented. 10 Manual Functional Safety for DRC Electronic Motor

Safety Conditions Approved devices 3 3 Safety Conditions The requirement for safe operation is that the safety functions of the DRC drive unit are properly integrated into an application-specific higher-level safety function. A system/machine-specific risk assessment must be carried out through the system/machine manufacturer and taken into account for the use of the drive system with DRC drive units. The system/machine manufacturer and the operator are responsible for compliance of the system/machine with applicable safety regulations. The following requirements are mandatory when installing and operating the DRC drive unit in safety-related applications. The requirements are divided into: Approved devices Installation requirements Requirements for external safety controllers and safety relays Startup requirements Operational requirements 3.1 Approved devices Only the following unit variants of DRC drive units are permitted for safety-related applications. Type code example Explanation Permitted variants DRC 2-015- SNI- A ECR /XX Product series DRC 1 2 Size 005 015 Power rating Installation technology SNI DSC DAC DBC Version A Extended control range ECR (standard) Options /IV /BY1C /BY2C /BW1 /BW2 Permitted application options: GIO12B GIO13B Manual Functional Safety for DRC Electronic Motor 11

3 Safety Conditions Installation requirements 3.2 Installation requirements Supply lines and STO control lines have to be routed in separate cables. The length of the cable from the safety controller to the DRC drive unit may not exceed 100 m. The wiring technology used must comply with EN 60204-1. The STO control lines must be routed according to EMC guidelines and as follows: Outside an electrical installation space: Shielded cables must be routed permanently (fixed) and protected against external damage, or equivalent measures have to be taken. Inside an electrical installation space: Individual conductors can be routed. Adhere to the regulations in force for the application. Ensure that parasitic voltages cannot be generated in the STO control lines. Observe the values specified for safety components when designing the safety circuits. The STO signal may not be used for feedback. Observe the notes in the "DRC Electronic Motor" operating instructions on EMC compliant installation. It is important that the shielding of the STO control line is connected to the housing at both ends. Only use grounded voltage sources with safe disconnection (PELV) according to VDE 0100 and EN 60204-1 for all signal interfaces (SBus, binary inputs, binary output, etc.) of the DRC drive unit and all SBus stations. In case of a single fault, the voltage between the outputs or between any output and grounded parts must not exceed DC 60 V. When planning the installation, observe the technical data of the DRC drive unit. Do not use the DC 24 V output of the DRC drive unit for safety-related applications with DRC drive units. 12 Manual Functional Safety for DRC Electronic Motor

Safety Conditions Installation requirements 3 WARNING No safe disconnection of the DRC drive unit. Severe or fatal injuries. Do not use the 24 V output for safety-related applications with DRC drive units. You can only jumper the STO input with 24 V if the DRC drive unit does not perform any safety functions. For safety-related applications with DRC drive units, the jumpers marked with "Caution, remove jumper for safety operation" must be removed, see following figures (in unit variants with STO plug connectors X5502 and X5503, the jumpers are not installed at the factory): DRC DBC B and DAC B Remove the jumpers between STO input (terminals 1/2) and 24 V output (terminals 4/5): CAUTION remove jumper for safety operation 3. CAUTION remove jumper for safety operation 1. 2. 4745809035 DRC DSC B and SNI B Remove the jumpers between STO input (terminals 1/2) and 24 V output (terminals 5/15): CAUTION remove jumper for safety operation CAUTION remove jumper for safety operation CAUTION remove jumper for safety operation CAUTION 3. remove jumper for safety operation 2. CAUTION remove jumper for safety operation CAUTION remove jumper for safety operation 4747351179 Manual Functional Safety for DRC Electronic Motor 13

3 Safety Conditions External safety controller requirements 3.3 External safety controller requirements A safety relay can be used as an alternative to a safety controller. The following requirements apply analogously. The safety controller and all other safety-related subsystems must be approved for at least that safety class which is required in the overall system for the respective, application-related safety function. The following table shows an example of the required safety class of the safety controller: Application Performance level e according to EN ISO 13849-1 SIL 3 according to EN 62061 Safety controller requirements Performance level e according to EN ISO 13849-1 SIL 3 according to EN 61508 Performance level e according to EN ISO 13849-1 SIL 3 according to EN 61508 The wiring of the safety controller must be suitable for the required safety class, (see manufacturer documentation). The STO input of the DRC drive unit requires 2-pole disconnection. The values specified for the safety controller must be strictly adhered to when designing the circuit. The switching capacity of safety relays or relay outputs of the safety controller must correspond at least to the maximally permitted, limited output current of the 24 V voltage supply. Observe the manufacturer's instructions concerning the permitted contact loads and fusing that may be required for the safety contacts. If the manufacturer provides no specific information, the contacts must be protected with 0.6 times the nominal value of the maximum contact rating specified by the manufacturer. To ensure protection against unintended restart in accordance with EN 1037, the safe control system must be designed and connected in such a way that resetting the control device alone does not lead to a restart. A restart may only be carried out after a manual reset of the safety circuit. 14 Manual Functional Safety for DRC Electronic Motor

Safety Conditions External safety controller requirements 3 Note the following for two-pole disconnection of the DRC drive unit with tested, safe outputs: When disconnected, the switch-on test pulses may never occur at the plus and minus output at the same time. When connected, the switch-off test pulses may not be longer than 1 ms. The next pulse blanking cannot reoccur earlier than after 20 ms. High: no STO <1 ms >20 ms Low: STO active t 9007201720642187 3.3.1 Sample circuit for a safety relay The following figure shows the basic connection of an external safety relay (according to the requirements listed above) to the DRC drive unit. The information in the respective manufacturer's data sheets must be observed for connection. [6] [3] [1] [2] U [4] [5] 2466502411 [1] Safety relay with approval [4] STO signal [2] DC 24 V voltage supply [5] Reset button for manual reset [3] Fuses in accordance with the manufacturer's [6] Permitted emergency stop actuating device specifications of the safety relay Manual Functional Safety for DRC Electronic Motor 15

3 Safety Conditions Startup requirements 3.4 Startup requirements To validate the implemented safety functions, they must be documented and checked after successful startup (validation). Observe the limitations for safety functions in chapter "Limitations" for the validation of the safety functions. Non-safety-relevant parts and components that affect the result of the validation test must be deactivated, if necessary. When you are using the DRC drive unit in safety-relevant applications, it is essential that you perform and record startup checks for the disconnecting device and correct wiring. 3.5 Operational requirements Operation is only allowed within the limits specified in the data sheets. This principle applies to the external safety controller as well as to the DRC drive unit and approved options. The built-in diagnostic function is limited in case of a permanently enabled or permanently disabled STO input. Only when the STO signal is activated ("Low" to "High"), extended diagnostic functions are performed. This means that the STO input must be switched at least once in three months while the supply system is connected to achieve a complete test coverage. Follow this test procedure: High: no STO max. 3 months >500 ms >500 ms Low: STO active internal diagnostics internal diagnostics t 2467673483 To achieve complete test coverage after a unit reset (e.g. after connecting the supply system), the test transition (STO active not active) must be started at least 10 seconds later. The unit must (already) be signaling "ready for operation" or "STO safe torque off" and may not be in error state. A detected hardware fault in the internal switch-off channels for STO will lead to a locking error state of the DRC drive unit. When the error is reset (e.g. by switching the power supply off and back on), a complete internal diagnostics test run must be performed according to the above test procedure. If the error re-occurs, replace the unit or contact SEW Service (for detailed information about possible error states, refer to the respective DRC operating instructions). 16 Manual Functional Safety for DRC Electronic Motor

Technical Data kva i P n f Hz 4 4 Technical Data The table below shows the technical data of the DRC drive unit related to integrated safety technology. The technical data and approvals in the respective DRC operating instructions must be observed in addition. Technical data of the STO input Min. Typical Max. Unit Input voltage range -3 24 30 DC V Input impedance 1000 Ohm Switch-on/switch-off threshold 11 V Input voltage for ON status (STO) 15 V Input voltage for OFF status (STO) 5 V Permitted leakage current of the external 0 2 ma safety controller Time from disconnecting the safety voltage 4 20 ms until the deactivation of the rotating field Time from connecting the safety voltage until 220 300 ms the deactivation of the rotating field Test interval for STO function: See test procedure in chapter "Operation requirements" 3 Months Safety characteristics Approved safety classes SIL 3 according to IEC 61800-5-2 Performance level e according to EN ISO 13849-1 Probability of a dangerous failure per hour 2 10 9 1/h (= PFH value) Service life 20 years, after which the component must be replaced with a new one. Safe condition Safe torque off (STO) Manual Functional Safety for DRC Electronic Motor 17

5 Appendix Unit variants with optional standard brake 5 Appendix 5.1 Unit variants with optional standard brake The standard brake that can optionally be integrated in DRC drive units is not safetyrelated and therefore not part of the safety functions described in the "Safety functions" chapter. We recommend SS1 (c) control; the brake is applied at 0 rpm. In this case, the factory setting of the following parameters must not be changed: Index Parameter Factory setting 8584.0 Brake function 1 = ON: The drive decelerates along the set ramp. Once 0 rpm is reached, the brake is activated. 9833.20 STO brake application 1 = YES: The brake is applied when STO is triggered Speed Deceleration ramp Drive enable signal Control signal STO active Brake inactive t 1 t t 2 t 4744670987 t t 1 t 2 t Time Point of time at which the brake ramp is initiated Point of time when STO is triggered Time between initiating the brake ramp and STO Safe time delay range Disconnection range 18 Manual Functional Safety for DRC Electronic Motor

Appendix Unit variants with optional standard brake 5 If STO is activated before 0 rpm is reached, the brake behaves as set in parameter "9833.20 STO brake application": [1] Parameter "9833.20 STO brake application" = 1 (factory setting) The brake is applied when STO is triggered INFORMATION Note the permitted "emergency off braking operations" of the brake in chapter "Technical Data" in the operating instructions. [2] Parameter "9833.20 STO brake application" = 0 The motor coasts to a halt The brake is not activated The deceleration distance is not defined [2] Speed Deceleration ramp Drive enable signal [1] Control signal STO [1] active Brake inactive t 1 t t 2 t 4744860555 [1] Parameter "9833.20 STO brake application" = 1 (factory setting) [2] Parameter "9833.20 STO brake application" = 0 t Time t 1 Point of time at which the brake ramp is initiated t 2 Point of time when STO is triggered t Time between initiating the brake ramp and STO Safe time delay range Disconnection range Activating the STO function during the execution of the ramp aborts the controlled rampdown: Possible reasons for premature activation of STO: Deceleration time t too short Extension of the deceleration ramp due to current limit, e.g. load too high Manual Functional Safety for DRC Electronic Motor 19

5 Appendix Connection variants 5.2 Connection variants 5.2.1 Position of the terminals for safe torque off (STO) The following figure shows an example of the terminal positions for safe torque off (STO) of the DRC drive unit: PE PE 4749325835 5.2.2 Assignment of the terminals for safe torque off (STO) The following figure shows the terminal assignment for safe torque off (STO) of the DRC drive unit: Assignment No. Name Color Function 1 STO+ Yellow Input STO+ 2 STO Yellow Input STO 11 STO+ Yellow Output STO + (to loop through) 12 STO Yellow Output STO (to loop through) INFORMATION For information about looping through STO, refer to chapter "Connecting an external safety relay for STO". Connection cable INFORMATION Use only shielded cables for this connection. 20 Manual Functional Safety for DRC Electronic Motor

Appendix Connection variants 5 5.2.3 Position of the optional plug connectors for safe torque off (STO) The STO plug connectors X5502 "STO IN" and X5503 "STO OUT" are always in "position 3" as shown in the following figure: Plug connector Color Location Position X5502: STO IN Orange Fixed 3 (left) X5503: STO OUT Orange Fixed 3 (right) X 2 3 X5502 STO-IN X5503 STO-OUT 18014401007607307 INFORMATION For information about looping through STO, refer to chapter "Connecting an external safety relay for STO". Manual Functional Safety for DRC Electronic Motor 21

5 Appendix Connection variants 5.2.4 Assignment of the optional plug connectors for safe torque off (STO) X5502: STO IN WARNING No safe disconnection of the DRC drive unit. Severe or fatal injuries. Do not use the 24 V output (pin 1 and pin 3) for safety-related applications with DRC drive units. You can only jumper the STO input with 24 V if the DRC drive unit does not perform any safety functions. The following table informs about this connection: Function Input for safe torque off (STO) Connection type M12, 5-pole, female, A-coded Wiring diagram 1 2 4 3 5 2264816267 Assignment No. Name Function 1 +24V_O DC 24 V output 2 STO Input STO 3 0V24_O 0V24 reference potential 4 STO+ Input STO+ 5 res. Reserved 22 Manual Functional Safety for DRC Electronic Motor

Appendix Connection variants 5 Connection cable INFORMATION For this connection, only use shielded cables and suitable plug connectors for an HFcompatible connection of the shield with the unit. The following table provides an overview of the cables available for this connection: Connection cable Part number 1 812 496 8 Length/ Installation type Operating voltage Variable DC 60 V M12, 5-pole, A-coded M12, 5-pole, A-coded Part number 1 812 497 6 Variable DC 60 V M12, 5-pole, A-coded Open Part number 1 812 740 1 Variable DC 60 V M12, 5-pole, A-coded M12, 5-pole, A-coded Part number 1 812 739 8 Variable DC 60 V M12, 5-pole, A-coded Open Connection of cables with open end The following table shows the conductor assignment of the cable with the following part number: 1 812 497 6 and 1 812 739 8 Signal name Core color/designation STO Black / 1 STO+ Black / 2 Manual Functional Safety for DRC Electronic Motor 23

5 Appendix Connection variants X5503: STO OUT The following table provides information about this connection: Function Connection for safe torque off (STO) for looping through Connection type M12, 5-pole, male, A-coded Wiring diagram 2 1 3 5 4 2264818187 Assignment No. Name Function 1 res. Reserved 2 STO Output STO (to loop through) 3 res. Reserved 4 STO+ Output STO + (to loop through) 5 res. Reserved Connection cable INFORMATION For this connection, only use shielded cables and suitable plug connectors for an HFcompatible connection of the shield with the unit. The following table provides an overview of the cables available for this connection: Connection cable Part number 1 812 496 8 Length/ Installation type Operating voltage Variable DC 60 V M12, 5-pole, A-coded M12, 5-pole, A-coded Part number 1 812 740 1 Variable DC 60 V M12, 5-pole, A-coded M12, 5-pole, A-coded 24 Manual Functional Safety for DRC Electronic Motor

Appendix Connection of an external safety relay for STO 5 5.3 Connection of an external safety relay for STO 5.3.1 Connection via terminals The following figure shows a connection example with a safety relay and disconnection of all poles: [1] [3] DC +24 V [2] 1 STO + IN 2 STO IN 11 STO + OUT 12 STO OUT [4] 2468014347 [1] Installation space [2] Safety relay [3] DRC drive unit [4] Connection terminals for STO 5.3.2 Connection via M12 plug connector The following figure shows a connection example with a safety relay and disconnection of all poles: [1] [3] DC +24 V 4 2 [4] X5502 STO IN [2] 2468645003 [1] Installation space [2] Safety relay [3] DRC drive unit [4] Plug connector for STO INFORMATION When wiring the STO signals, possible faults in plug connectors and cables/lines have to be considered (see ISO 13849-2) and the installation has to be designed according to the required safety class. The DRC drive unit does not detect short circuits in the supply line. SEW-EURODRIVE therefore recommends to connect only STO signals to the STO input using a two-core cable, as shown in the figure. Manual Functional Safety for DRC Electronic Motor 25

5 Appendix Connection of an external safety relay for STO 5.3.3 Connection via terminals group disconnection The following figure shows a connection example for disconnection of group drives with a safety relay: [1] [3] DC +24 V [2] 1 STO + IN 2 STO IN 11 STO + OUT 12 STO OUT [4] [3] 1 STO + IN 2 STO IN 11 STO + OUT 12 STO OUT [4] 2468651531 [1] Installation space [2] Safety relay [3] DRC drive unit [4] Connection terminals for STO 26 Manual Functional Safety for DRC Electronic Motor

Appendix Connection of an external safety relay for STO 5 5.3.4 Connection via M12 plug connector group disconnection The following figure shows a connection example for disconnection of group drives with a safety relay: [1] [3] DC +24 V 4 2 X5502 STO IN [2] [4] 2 4 X5503 STO OUT 4 2 [3] X5502 STO IN [4] 2 4 X5503 STO OUT 2468653451 [1] Installation space [3] DRC drive unit [2] Safety relay [4] Plug connector for STO INFORMATION When wiring the STO signals, possible faults in plug connectors and cables/lines have to be considered (see ISO 13849-2) and the installation has to be designed according to the required safety class. The DRC drive unit does not detect short circuits in the supply line. SEW-EURODRIVE therefore recommends to connect only STO signals to the STO input using a two-core cable, as shown in the figure. Manual Functional Safety for DRC Electronic Motor 27

5 Appendix Connection of an external safety relay for STO 5.3.5 STO signal for group disconnection Requirements For group drives, the STO signal for several DRC drive units can be provided by a single safety relay. The following requirements must be met: For EMC reasons, the maximum cable length is limited to max. 100 m. Other instructions published by the manufacturer on the use of safety relays (for specific applications) must also be observed. The maximum output current/the maximally permitted contact load of the safety relay must be observed. You must observe the permitted signal levels at the STO input and all other technical data of the DRC drive unit. The routing of the STO control cables and the voltage drop must be considered. Other requirements of the safety relay manufacturer (such as protecting the output contacts against welding) must be strictly observed. You must also observe the basic cable routing requirements from chapter "Installation requirements". A calculation based on the technical data of the DRC drive unit must be performed separately for each case of group drive disconnection. 28 Manual Functional Safety for DRC Electronic Motor

Appendix Connection of an external safety controller for STO 5 5.4 Connection of an external safety controller for STO 5.4.1 Connection via terminals The following figure shows a connection example with a safety controller and disconnection of all poles for STO: [1] [2] [3] DOn_P DOn_M 1 STO + IN 2 STO IN 11 STO + OUT 12 STO OUT [4] 2471315851 [1] Installation space [2] Safety controller [3] DRC drive unit [4] Connection terminals for STO 5.4.2 Connection via plug connector The following figure shows a connection example with a safety controller and disconnection of all poles for STO: [1] [3] [2] [4] DOn_P DOn_M 4 2 X5502 STO IN 2471842571 [1] Installation space [2] Safety controller [3] DRC drive unit [4] Plug connector for STO INFORMATION When wiring the STO signals, possible faults in plug connectors and cables/lines have to be considered (see ISO 13849-2) and the installation has to be designed according to the required safety class. The DRC drive unit does not detect short circuits in the supply line. SEW-EURODRIVE therefore recommends to connect only STO signals to the STO input using a two-core cable, as shown in the figure. Manual Functional Safety for DRC Electronic Motor 29

5 Appendix Connection of an external safety controller for STO 5.4.3 Connection via terminals group disconnection The following figure shows a connection example for disconnection of group drives with a safety controller: [1] [2] [3] DOn_P DOn_M 1 STO + IN 2 STO IN 11 STO + OUT 12 STO OUT [4] [3] 1 STO + IN 2 STO IN 11 STO + OUT 12 STO OUT [4] 2808079627 [1] Installation space [2] Safety controller [3] DRC drive unit [4] Connection terminals for STO 30 Manual Functional Safety for DRC Electronic Motor

Appendix Connection of an external safety controller for STO 5 5.4.4 Connection via M12 plug connector group disconnection The following figure shows a connection example for disconnection of group drives with a safety controller: [1] [2] [3] DOn_P DOn_M 4 2 X5502 STO IN [4] 2 4 X5503 STO OUT [3] 4 2 X5502 STO IN [4] 2 4 X5503 STO OUT 2808077707 [1] Installation space [3] DRC drive unit [2] Safety controller [4] Plug connector for STO INFORMATION When wiring the STO signals, possible faults in plug connectors and cables/lines have to be considered (see ISO 13849-2) and the installation has to be designed according to the required safety class. The DRC drive unit does not detect short circuits in the supply line. SEW-EURODRIVE therefore recommends to connect only STO signals to the STO input using a two-core cable, as shown in the figure. Manual Functional Safety for DRC Electronic Motor 31

5 Appendix Connection of an external safety controller for STO 5.4.5 STO signal for group disconnection Requirements For group drives, the STO signal for several DRC drive units can be provided by a single safety controller. The following requirements must be met: For EMC reasons, the maximum cable length is limited to max. 100 m. Other instructions published by the manufacturer on the use of the safety controller (for the respective application) must also be observed. The maximum output current/the maximally permitted contact load of the safety controller must be observed. You must observe the permitted signal levels at the STO input and all other technical data of the DRC drive unit. The routing of the STO control cables and the voltage drop must be considered. Other requirements stipulated by the manufacturer of the safety controller must be strictly observed. You must also observe the basic cable routing requirements from chapter "Installation requirements". A calculation based on the technical data of the DRC drive unit must be performed separately for each case of group drive disconnection. 32 Manual Functional Safety for DRC Electronic Motor

Index Index A Application options, approved...11 Approved devices...11 Area of application...4 B Brake...18 C Cable length...28, 32 Conditions, safety...11 Devices, approved...11 Conditions, safety-relevant External safety controller requirements...14 Installation requirements...12 Operational requirements...16 Startup requirements...16 Connection External safety controller for STO...29 External safety relay for STO...25 Connection via M12 plug connector External safety controller...29 External safety relay...25 Connection via M12 plug connectors External safety controller - group disconnection...31 External safety relay - group disconnection...27 Connection via terminals External safety controller...29 External safety controller - group disconnection...30 External safety relay...25 External safety relay - group disconnection...26 Copyright...5 E Embedded safety notes...5 EMC conditions...12 Exclusion of liability...5 External safety controller, requirements...14 External safety relay, requirements...14 G Group disconnection Connection via M12 plug connectors...27, 31 Connection via terminals...26, 30 STO signal for group disconnection...28, 32 I Installation instructions...12 N Notes Designation in the documentation...4 P PFH value...17 Plug connector for STO, optional...21 Assignment...22 Connection cable...23, 24 Position...21 Plug connectors for STO, optional Assignment...24 Probability of a dangerous failure...17 Product names...5 Pulse blanking...15 R Removing jumpers...13 Representation of safety concept, schematic...7 Requirements For installation...12 For operation...16 For startup...16 For the external safety controller...14 Restrictions...10 Rights to claim under limited warranty...5 S Safe condition...6, 17 Safe Stop 1, function variant c (SS1(c))...9 Safe torque off (STO)...8 Safety characteristics...17 Safety classes, approved...17 Safety concept...6 Safety conditions...11 Safety controller, requirements...14 Manual Functional Safety for DRC Electronic Motor 33

Index Safety notes Designation in the documentation...4 Structure of the embedded safety notes...5 Structure of the section-related safety notes...4 Safety relay Requirements...14 Sample circuit...15 Safety technology Restrictions...10 Safe condition...6 Safety concept...6 Schematic representation...7 Section-related safety notes...4 Signal words in the safety notes...4 SS1(c) (Safe Stop 1, function variant c)...9 Standards...4 STO input...17 STO signal for group disconnection...28, 32 STO (safe torque off)...8 Switching capacity of the safety relay...14 T Technical data Safety characteristics...17 STO input...17 Terminals for STO...20 Assignment...20 Position...20 Test setup...16 Testing the disconnecting device...16 Trademarks...5 V Validation...16 Verification of safety functions...16 W Wiring specifications...12 Wiring technology...12 34 Manual Functional Safety for DRC Electronic Motor

SEW-EURODRIVE Driving the world SEW-EURODRIVE Driving the world SEW-EURODRIVE GmbH & Co KG P.O. Box 3023 D-76642 Bruchsal/Germany Phone +49 7251 75-0 Fax +49 7251 75-1970 sew@sew-eurodrive.com www.sew-eurodrive.com