E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Similar documents
E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2K-X4ME1 2M E2K-X4ME2 2M

Long Sensing-distance Capacitive Separate Amplifier Proximity Sensor E2J-W10MA 1M E2J-W20MA 1M. E2J-JC4A Amplifier Unit

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

Aluminum-detecting Proximity Sensor (Separate Amplifier Type)

Shape Model Measurement range Model Straight 50 to 300 mm. Straight 70 to 800 mm

E2EC. High-sensitivity DC 2-Wire Sensors and Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

Reliable Detection Unaffected by PCB Holes or Notches. PCB Sensors. Ordering Information. Sensors [Refer to Dimensions on page 4.

NPN output. 200 mm. Type Cable length Model Remarks

E3S-GS/VS. Both Red-light Models and Greenlight Models to Detect a Wide Variety of Colors. Small Spot/Mark Sensor with Built-in Amplifier

Power supply voltage Output configuration Output phases Resolution (pulses/rotation) Model. 100, 200, 360 E6A2-CWZ5C (resolution) 0.

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

EE-SX77/87. Slim, Compact Photomicrosensor that is still easy to use. Photomicrosensor with Slim Cable (Non-modulated) Ordering Information

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

D5B. Detects Objects in Multiple Directions with High Sensitivity, Ideal for Robotics. Mechanical Touch Switch. Model Number Structure

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2.

EE-SX97 40% Built-in connector enables downsizing and easier connection. Protective circuit for safe operation. Slot-type Photomicrosensor.

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter

Output configuration Contact form Operation indicator Cable length Model PNP open collector. 1 m D5F-2B10 (+ common) ON when operated

Photoelectric Sensor

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

Model NPN output PNP output Standard. configuration

Model Number Structure

Smart Sensors (with Ultra-High-Speed CCD Camera) ZFV Series

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction.

Model Number Structure

Snap-in (front mounting) Locking type. Terminals Solder terminals *1 Color Light gray Black A7BL-207 *2 A7BL *2

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

NJ-Series Power Supply Unit NJ-PA/PD

Intelligent Flag Amplifier

Communication Unit Dedicated for RFID V680 Allowing Direct Connection to OMRON PLC CJ/ CS/NJ-series

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

Handheld Reader Writer

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4 40 XW2B-40G5 *1 50 XW2B-50G5 60 XW2B-60G5 40 XW2B-40G5-T

Model Number Structure

Limit Switch Connectors

E4C-UDA CSM_E4C-UDA_DS_E_12_2

CJ1W-INT01. CJ-series Interrupt Input Units. High-speed Starting of I/O Interrupt Tasks. Use Up to Two Units for a Total of Up to 32 Interrupt Inputs.

Name Specifications Model Standards. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

(75 to 264 VAC) 12 VDC 24 VDC No 5 VDC G3MC-202PL 12 VDC 24 VDC

Sensing method Appearance Connection method Sensing distance Model. Pre-wired (2 m) Power supply Application Appearance Function Model

Limit Switch Connectors

Model Number Structure

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

Model Number Structure

Switching Frequency Test Conditions (AC3/AC4/AC53-a)

Reverse Protection Relay 2. Control Power Supply Voltage None: 200/220 VAC 380: 380/400 VAC 440: 440 VAC

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Model Number Structure

M16. Cylindrical 16-dia. Indicator. Indicator (Cylindrical 16-dia.) List of Models. Same basic design as the A16 Pushbutton Switch.

G9SA. Safety Relay Unit. The G9SA Series Offers a Complete Line-up of Compact Units. Model Number Structure

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units.

Solid State Relays with Failure Detection Function

Thread length (overall length)

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

250 mm 1 m. Name Sensing distance Model Quantity Remarks 250 mm E39-R6 1 Supplied with the product. Reflectors 1 m [250 mm] * E39-R

Model Number Structure

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

E2FM. Inductive Proximity Sensor in full metal housing. Application. Continuous Impact Test. Brush Test

Model NPN output PNP output Standard. configuration

E6J-C. Ultracompact Rotary Encoder with External Diameter of 20 mm. Ultracompact 20-mm-dia. Incremental Rotary Encoder. Ordering Information

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

Peripheral Devices for Environment-resistive Slaves

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

E2K-C. Long-distance Capacitive Sensor with Adjustable Sensitivity. Long-distance type. Ordering Information. Sensors [Refer to Dimensions on page 8.

Model Number Structure

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

DPDT Basic Switch for Two Independent Circuit Control

Origin Position Control of an X-Y Table Coaxiality Inspection Checking Turret Indexing Position D5A

Model A7BS

Through-beam pre-wired E3F1-TN11 2M *1 E3F1-TP11 2M *1 15 m. pre-wired E3F1-RN11 2M E3F1-RP11 2M 0.1 to 3 m

S82S (3/7.5-W Models)

ID Sensor Modules CJ1W-V600C11/V600C12 CS1W-V600C11/V600C12

F3SL. Safety Light Curtain for Long Distance Detection

Number of input channels

Reflective Photomicrosensor with Sensitivity Adjuster (Non-modulated)

configuration Dark-ON/Light-ON (selectable) *3 Dark-ON/Light-ON (selectable) *3 Dark-ON/Light-ON (selectable) *3 Dark-ON/Light-ON (selectable) *3

P7TF-IS16/OS16/OS08. I/O classification I/O points Internal I/O common Rated voltage Model 12 VDC P7TF-IS16 DC12 24 VDC P7TF-IS16 DC24 For inputs

Photoelectric Sensor

E2E. High performance in small sizes. Miniature Cylindrical Proximity Sensor. Ordering Information

Features. Measuring and Monitoring Relays K8AB Series. Cut by 50% Industry First! Two SPDT Outputs Available in New Models DIN Sized at 22.

Multi-beam, finger- and hand protection safety sensor. Multi-beam, finger and hand protection safety sensor. Model number structure

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

Conductive Level Controller

Photoelectric Sensor. Threaded Cylindrical Photoelectric Sensors with Built-in Amplifier for Use as an Optical Proximity Sensor

Electroformed Probe Pins XP3A

Model Number Structure

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

No. of I/O points Safety inputs Test outputs Safety outputs NE1A-SCPU01-EIP NE1A-SCPU02-EIP 1.0

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output

ZN-CTX/-CTM. Portable Power Monitor. Easy and Quick Checking Power at the Worksite. Ordering Information. Portable Power Monitor

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC

CSM_PYF S/P2RF- -S_DS_E_2_5

Type High-sensitivity. Medium-sensitivity models models Sensed current 30 ma (fixed) 100 ma/200 ma 200 ma/500 ma 500 ma/1,000 ma Operating time

Transcription:

Flat Proximity Sensor EK-F CSM_EK-F_DS_E Flat Capacitive Sensor with a Thickness of Only mm Flat Sensor with excellent space efficiency. (Model with built-in Amplifier is only mm thick.) Direct mounting onto a metallic surface is possible. Be sure to read Safety Precautions on page. Ordering Information Sensors [Refer to Dimensions on page.] Appearance Sensing distance Output configuration Model/Operation mode NO NC Flat Unshielded mm to mm DC -wire NPN EK-FMC M EK-FMC-A M EK-FMC M EK-FMC-A M

Ratings and Specifications EK-F Item Model EK-FMC@-A EK-FMC@ Sensing distance to mm (adjustable with -turn adjuster) mm ±% Set distance 0 to. mm * Differential travel Detectable Standard sensing Response frequency Power supply voltage (operating voltage range) * The value for the EK-FMC@-A is when it is adjusted to mm. Engineering Data (Typical) % max. of sensing distance Conductors and dielectrics Grounded metal plate: 0 0 mm 0 Hz to VDC ( to 0 VDC), ripple (p-p): % max. Current consumption ma max. at VDC Control Load current NPN open collector, 0 ma max. (at 0 VDC) output Residual voltage. V max. (Load current: 0 ma, Cable length: m) Indicators Operation mode (with sensing approaching) Protection circuits Ambient temperature range Detection indicator (red) NO (Refer to the timing charts under I/O Circuit Diagrams on page for details.) Reverse polarity protection, Surge suppressor Operating/Storage: to C (with no icing or condensation) Ambient humidity range Operating/Storage: % to % Operating/Storage: % to % Temperature influence ±% max. of sensing distance at C in the temperature range of to C Voltage influence ±.% max. of sensing distance at rated voltage at rated voltage ±% Insulation resistance Dielectric strength Vibration resistance Shock resistance 0 MΩ min. (at 00 VDC) between current-carrying parts and case 00 VAC, 0/0 Hz for min between current-carrying parts and case Destruction: to Hz,.-mm double amplitude for hours each in X, Y, and Z directions Destruction: 00 m/s times each in X, Y, and Z directions Degree of protection IP (IEC) IP (IEC) Connection method Pre-wired Models (Standard cable length: m) Weight (packed state) Materials Accessories Case Sensing surface Approx. g Heat-resistant ABS Instruction manual Sensing Area (Grounded Plate) Influence of Sensing Object Size and Material Distance X (mm) Left and right Y X Distance X (mm) Up and down Y X Distance (mm) Grounded metal plate (t = ) Non-grounded metal plate (t = ) Glass (t = ) Phenol (t = ) 0 0 Sensing Head 0 Distance Y (mm) 0 0 Sensing Head 0 Distance Y (mm) 0 0 0 0 0 0 0 0 Side length of sensing (mm)

EK-F I/O Circuit Diagrams NO Models NC Models Timing chart Sensing Output transistor (load) Present Not present ON OFF Detection indicator (red) ON OFF 0 Ω Brown +V Output circuit Proximity Sensor main circuit Load * Black Output Blue 0 V * Load current: 0 ma max. Safety Precautions Refer to Warranty and Limitations of Liability. WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. Mutual Interference When mounting more than one EK-F face-to-face or side-by-side, separate them as shown below. Precautions for Correct Use 0 mm 0 mm 0 mm Do not use this product under ambient conditions that exceed the ratings. Design Sensing Object Material The EK-F can detect almost any type of. The sensing distance of the EK-F, however, will vary with the electrical characteristics of the, such as the conductance and inductance of the, and the water content and capacity of the. The maximum sensing distance of the EK-F will be obtained if the is made of grounded metal. There are s that cannot be detected indirectly. Therefore, be sure to test the EK-F in a trial operation with the s before using the EK-F in actual applications. Influence of Surrounding Separate the EK-F from surrounding metal as shown below. Effects of a High-frequency Electromagnetic Field The EK-F may malfunction if there is an ultrasonic washer, highfrequency generator, transceiver, portable telephone, or inverter nearby. For major measures, refer to Noise of Warranty and Limitations of Liability for Photoelectric Sensors. Wiring Close mounting possible Face-to-face mounting The characteristics of the EK-F will not change if the cable is extended. Extending the cable, however, will result in a voltage drop, so do not extend the length past 00 m. 0 mm 0 mm mm

Dimensions EK-F EK-F (Unit: mm) Tolerance class IT applies to dimensions in this data sheet unless otherwise specified. Mounting Hole Dimensions Two, M or. dia. Sensitivity adjuster * 0 * ±0. Detection indicator (red). Two,. dia. 0 *. Only the EK-FMC@-A has a sensitivity adjuster. *..-dia. vinyl-insulated round cable (Conductor cross section: 0. mm, Insulator diameter: 0. mm), Standard length: m.

Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 0. In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 0 All Right Reserved.