Chiller Replacement and System Strategy. Colin Berry Account Manager

Similar documents
Efficiency of Data Center cooling

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Optimizing Chilled Water Plant Performance. David Herman, PE, LEED AP Principal EnerG Associates, LLC

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

Engineered Energy Solutions An Overview. Controls, Automation and Energy Conservation

Liebert. HPC-S Free Cooling Chiller Designed for the Efficient Cooling of Small Data Centers

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

TWO FINANCIAL IMPACT STUDIES. Seal IT Equipment Cabinets for Significant Annual Cost Savings and Simple Payback in a Few Short Months

Energy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.

CGAM air-cooled scroll chiller. Highly efficient, yet extremely quiet

Retro-Commissioning Report

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

MSYS 4480 AC Systems Winter 2015

Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

Switch to Perfection

AuraCool Economizer System

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

where we are, where we could be, how we can get there. 12/14/2011

MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers

Data Center Energy Savings By the numbers

2000 kw, Tier 3, Chilled Water, Prefabricated, sq. ft.

Virtualization and consolidation

Cisco Lab Setpoint Increase. Energy Efficient Data Center Demonstration Project

Comprehensive Energy Management & Utility Master Plan

UC DAVIS THERMAL ENERGY STORAGE (TES) TANK OPTIMIZATION INVESTIGATION MATTHEW KALLERUD, DANNY NIP, MIANFENG ZHANG TTP289A JUNE 2012

Trane Engineering News Chiller Plant Case Study: Variable-Primary Flow Series Chillers with Free Cooling

ENCLOSURE HEAT DISSIPATION

ECOBAY: Closed loop water cooled server cabinet for data centers

Data Center Optimized Controls

Motivair MLC-SC Air-Cooled Scroll Chillers Tons

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

EDX DC-3 environmental monitoring solution

Silicon Valley Power Data Center Program Rebate Application

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

Standard Circulating Pumps

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency

Thermal management. Thermal management

Rittal Cooling Solutions A. Tropp

Liebert DCW CATALOGUE

18 th National Award for Excellence in Energy Management. July 27, 2017

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

CRAH Retrofit and Energy Savings Project

Standard Circulating Pumps

LIFE CYCLE COST ANALYSIS, CRITERIA AND DATA SHEETS DOCUMENT NUMBER: APPLICATION: ELEMENTARY, MIDDLE AND HIGH SCHOOL

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

Hot vs Cold Energy Efficient Data Centers. - SVLG Data Center Center Efficiency Summit

1008 kw, Tier 2, Chilled Water, ft 2

Energy Management of the Refrigeration Systems at Zurich Airport. Burkhard Bein. Schaffhausen,

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

HIGH EFFICIENCY Central Chiller

SYRACUSE UNIVERSITY GREEN DATA CENTER NYSERDA MONITORING PLAN BHP ENERGY LLC. February 17, 2010 Revised

The Efficient Enterprise. All content in this presentation is protected 2008 American Power Conversion Corporation

Air-Cooled Series R Chiller

2017 NEHES Fall Conference Technical Breakout Session: Deep Chiller Plant Optimization

GP SERIES Packaged Chillers

Optimiz Chilled January 25, 2013

Trane mytest Water-cooled Chiller Performance Validation What you spec is what you get *

Green IT Project: The Business Case

Green IT and Green DC

Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability

Achieving Operational Excellence

Reducing Data Center Cooling Costs through Airflow Containment

HP Modular Cooling System: water cooling technology for high-density server installations

DEDICATED HEAT RECOVERY UNIT (DHRC)

HIGH DENSITY RACK COOLING CHOICES

PROCESS COOLING STUDY WORKSHEET

CASE STUDIES. Brevard Community College: Florida Power & Light. Cape Canaveral Air Force Station: NORESCO

APC APPLICATION NOTE #126

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

Ft Worth Data Center Power Metering for Real Time PUE Calculation. Scope of Work

Next Generation DCP Optimization using MV VSDs

Data Center Temperature Design Tutorial. Ian Seaton Chatsworth Products

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

Trailblazer AGZ-E air-cooled scroll chillers

Chilled Water Distribution Design Considerations in Super Tall Buildings. Dusan Mrdalj, Associate, ChapmanBDSP

IBM - Energy Efficiency Recommissioning: Improving Buildings Systems Efficiency Jean-Pierre Boulianne, Pierre Lefèbvre, Yves Veilleux ICEBO 2013

System Overview. Liquid Cooling for Data Centers. Negative Pressure Cooling Without Risk of Leaks

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

APC InRow Cooler Prototype Initial Report - Test Setup Verification. H. Coles, S. Greenberg Contributing: J. Bean (APC) November 18, 2011

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

Chiller Plant Optimization: A Case Study

Optimizing Cooling Performance Of a Data Center

HOURLY ANALYSIS PROGRAM v5.00 and v5.01

Water cooled chiller plant (all-variable)

What s New for Data Centers in Title Jeff Stein, PE Taylor Engineering

LCP Hybrid Efficient performance with heat pipe technology

Data Center Energy and Cost Saving Evaluation

Data Center Trends: How the Customer Drives Industry Advances and Design Development

Reference Design Quicktour Design Summary

Using CFD Analysis to Predict Cooling System Performance in Data Centers Ben Steinberg, P.E. Staff Applications Engineer

Measurement and Management Technologies (MMT) for more energy efficient Data Center and Telecommunication Facilities

Commercial Retro-Commissioning Program Manual for 2016 SECTION 1

CHAPTER/REGIONAL TECHNOLOGY AWARD - SHORT FORM

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

CenterPoint Energy Retro-Commissioning Program Application

IT Air Conditioning Units

Transcription:

Chiller Replacement and System Strategy Colin Berry Account Manager

Current Situation 4 Existing RTAA chillers All units 23 years old Limited service history One unit MUST be replaced immediately One unit operating on single circuit Two machines operating normally System has 4 chillers feeding a main chilled water line Chilled water used for cooling of OR rooms Critical cooling system, redundancy required.

Possible Option #1 OPTION 1 Replace 4 existing chillers with 4 identical new chillers Fixes immediate deficiency Will require heavy maintenance on remaining chiller(s) that will be replaced at a later date Potential for chiller failure at any time Lowest 1 st capital cost Limited expandability No load shedding capability Unable to take advantage of peak demand savings Phase two would consist of replacing the remaining chillers at a later date.

Possible Option #2 OPTION 2 Replace two chillers with a single Ice enhanced chiller, Phase 2 will add a second screw chiller to the system Fixes immediate deficiency Less than five year payback on investment Lowest life cycle cost Leading technology with built in redundancy Ice Storage system allows load shifting and lower ambient operational efficiency gains.

Possible Option #2 Continued OPTION 2 Utility rates forecast to increase 40% in 5 years Time of day billing is immanent Future incentives may be available for load shifting to off peak Less mechanical equipment for future maintenance Packaged controls Remote monitoring of system to address problems before the occur

Economics Review Option # Approximat e Installed Cost Yearly Utility Cost 1 st Year Maint. Final Year Maint. 1 $462,975 $70,494 $10,500 $12,634 2 $770,637 $46,703 $8,500 $11,434 Note: Figures above do not include rebates

Rebates Hydro One offers a very enticing rebate program Based upon removing KW from the grid Thermal storage adds cooling tons while reducing mechanical system KW This can fund a good portion of this project.

Rebates Review existing system

Rebates Review direct replacement system Unit Power = 132.6KW New 130 ton Trane CGAM

Rebates Direct replacement calculations Option 1: replace all four existing chillers with new Scroll Chillers, controls Existing chillers are 167.4 KW Each Current installed kw: 167 x 4 = 668 kw(4 X 130 ton chillers) Future installed kw: 152 x 4 = 608 kw(4 X 130 ton chillers) Rebate: (668-608) x $800 = $48,000 Phase 1: [(167 x 2) (134.5 x 2)] *$800 = $24,000 (Based on 2 replacements each phase) Phase 2: [(167 x 2) (134.5 x 2)] *$800 = $24,000 (Based on 2 replacements each phase) Installed cost: up: $462,975 (Estimated budget after all phases completed) Direct replacement chillers are After rebate first cost roll up: $414,975 132.6 KW Each Total installed tons: 544 tons in 4 chillers N-1 tons: 408 tons if one chiller is unavailable

Rebates ICE Storage calculations Option 2: In three phases, replace all four existing chillers with 2 Screw chillers (178 tons) plus 9 tanks, controls Current installed kw: 167 x 4 = 668 kw(4 X 130 ton chillers) Future installed kw: 126 x 2 = 252 kw( 2 X Trane chillers, thermal storage Existing chillers are 167.4 KW Each system) Rebate: (668-252) x $800 = $ 332,800 Phase 1: [(167 x 2) 126] * $800 = $166,400 (1 new Trane chiller, remove 2 chillers) Phase 2: no rebate (Install thermal storage system, 9 tanks) Phase 3: [(167 x 2) (126)] * $800 = $166,400 (1 new Trane chiller, remove 2 chillers) Installed cost rolls up: $ 770,637 (Estimated budget after all phases completed) After rebate first cost roll up: $ 504,397 Total installed tons: 536 tons in 2 chillers and 9 tanks N-1 tons: 403 tons if one 150 ton Ice Enhanced Chiller chiller is unavailable assuming 25 tons per tank (6 hours of discharge, 12 hours System uses 138.8 KW of charge) (Capacity left 1 chiller = 178 tons plus 25 tons X 9 tanks = 403 tons)

Energy Consumption Summary Notes: Alt 1 4 New 130 ton chillers Alt 2 Ice Storage Alt 3 Variable speed Option (JCI Proposal) Alt 4 Existing Conditions.

What Does Trane Bring to the Table? Turnkey contracting service Controls, Service and Equipment from one supplier Can tie into existing BMS Preventative maintenance to avoid losing efficiency Engineering and System Design Project Management including rebates We will be your single point of contact for the entire project and service period.

Similar First Cost How? On air cooled chiller jobs Key is partial ice storage If not lower you likely have too much ice REBATES

Important Notes on ICE Systems ICE tanks can be viewed as chillers in series. General rule of thumb is that chiller can be sized to 65% of total cooling load. Not Only are night electrical rates lower but the air cooled chiller is more efficient at low ambient. Each ICE tank is roughly 25 tons peak discharge and 160 useable ton-hours.

Good Analogy for Partial ICE Hybrid Car Hybrid Cooling

Partial Storage Basics Hybrid Car Reduced size, efficient engine Handles load efficiently most of the time Electric motors Kick in when extra power is needed Electric motors Are charged when plugged in, or braking, or by the engine Hybrid Cooling Right sized chiller(s) Handles load efficiently most of the time Energy Storage Kick in when extra cooling is needed Storage tanks Are efficiently charged at night when costs are low.

Model Number - 1190A Dimensions - OD x H 89" x 101" Filled Weight Floor Loading Inlet-Outlet Flange Connection Size Manufacturer Product Line Maximum Operating Pressure Maximum Operating Temperature Net-Usable Capacity Shipping Weight Volume Of Water-Ice Volume of Solution in HX 16765 lb 388 lb/sq ft 2" ICEBANK 90 psi 100 deg F 162 ton-hr 1950 lb 1655 gal 148 gal

Peak Design Load 300 Tons ICE percent 100% Full Storage Chiller Capacity (tons) Chiller Cost ($500/ton) No. of Tanks Tank Cost Total Cost 450 $225k 18 $270k $495k 80% 358 $176k 14 $210k $386k 60% 198 $99k 10 $150k $249k 40% 144 $72k 6 $90k $162k 0% 300 $150k 0 0 $150k

Why It Makes Sense for the Customer Lower first costs (both new construction and existing buildings) If Chillers are being replaced.. With a Combo of ice & chiller of same total capacity, properly sized, this can have basically have the same 1 st cost. And adding ice to same size chiller, this will increase overall system capacity. By keeping existing piping, pumps, and airside this is now a great opportunity to use the colder water and add VFDs to save pump and potentially airside energy Or with reduced supply air temperature Provide more cooling with same infrastructure Eliminate hot spots Reduced maintenance cost because of less tonnage

Single Pump System And We Can Keep These Systems Simple Lowest cost and simplest controls Often smaller systems But There are a few things to be aware of. Glycol throughout system Night cooling with cold water

Existing Chiller Plants Two Alternatives that Keep It Simple, and solve one or both problems. Eliminates the distribution of cold water during ice making, But still glycol in total system No glycol in the distribution system Plate & Frame Heat Exchanger

How Do You Make ICE Easy?

System Schematic Schematic representation of plant layout At a glance view of key system operating parameters

Trends and Gauges Dashboard style gauges and dials Links to Trend Logs showing key data

Savings Summary Quantifies savings associated with Ice storage Simulates system energy use without Ice Visual breakout of peak kw and electrical consumption savings

All Can be viewed https://home.ingerrand.com/our%20businesses/climatesolutions/sale s/earthwisesystems/pages/ice-enhancedair-cooledchillerplant.aspx

AC Chillers + ICE Storage Which can lead to Lower temperature fluid Can drive lower temperature air = less fan energy Will increase chilled water T on retrofits Larger chilled building loop T Drives lower flow rates = less pump energy AC chiller in series with ice storage tanks Series arrangement supports Variable Primary Flow (VPF) VPF saves on part-load pump energy All of the above help with earning LEED points via reduced energy costs!

Decision To Use ICE?