Setting Up a DH485 Network of (Bulletin 2750) intelligent Antennas Using a 27601RB Module and 2760=SFC2 Protocol Cartridge

Similar documents
Application Note. Overview. Hardware Requirements. Software Requirements

AdaptaScan Reader to a PLC-5 Using DH-485 Protocol with the 2760 RB Module and the 2760-SFC2 Protocol Cartridge

Dataliner Message Displays Using DL50 Slaves with a DL40 Master

AdaptaScan Reader to a PLC-5 Using RS-232/ASCII Protocol with the 2760 RB Module and the 2760-SFC1 and -SFC2 Protocol Cartridge

Instructions. (For 6180 Industrial Computers) Applications. Overview & Safety

Instructions. (For 6180 Industrial Computers) Installing a Processor Upgrade

Updates to Plastic Molding and Co-injection Modules (Catalog Numbers 1771-QDC and 1771-QI)

Reference Guide. (Catalog Number 1785 series) Introduction

8510 AC Spindle Drive Hardware/Firmware Replacement

AC/DC (120V) Input Module Cat. No IAD Series C

Access Code and Phone Number

A B A B. (Catalog Number 2707-MVH232, -MVP232) Product Data

Spoka Meet Audio Calls Rates Dial-In UK

EventBuilder.com. International Audio Conferencing Access Guide. This guide contains: :: International Toll-Free Access Dialing Instructions

Cisco Aironet In-Building Wireless Solutions International Power Compliance Chart

Allen-Bradley 1397 Enhanced Field Supply Card Cat. Nos FS FS1020

FLEX I/O: Flexible Solutions for Distributed Systems. FLEX I/O System

EE Pay Monthly Add-Ons & Commitment Packs. Version

iclass SE multiclass SE 125kHz, 13.56MHz 125kHz, 13.56MHz

GW-WN150M 11b/g/n USB Wireless User Manual

Artisan Scientific is You~ Source for: Quality New and Certified-Used/Pre:-awned ECJuiflment

END-OF-SALE AND END-OF-LIFE ANNOUNCEMENT FOR THE CISCO MEDIA CONVERGENCE SERVER 7845H-2400

ThinkPad carrying cases offer protection and convenience for your mobile requirements

No Purchase needed

Dashboard. Feb 18, Feb 18, 2008 Comparing to: Site. 13,318 Visits 28,414 Pageviews 2.13 Pages/Visit

Carrier Services. Intelligent telephony. for over COUNTRIES DID NUMBERS. All IP

Cisco CallManager 4.0-PBX Interoperability: Lucent/Avaya Definity G3 MV1.3 PBX using 6608-T1 PRI NI2 with MGCP

Cisco Voice Services Provisioning Tool 2.6(1)

MANUAL VOICE/DATA SIMCARD CANADA

ThinkPad carrying cases offer protection and convenience for your mobile requirements

Expanding ArmorBlock I/O Family Increases Packaging Choices and Interface Options for a Variety of Applications.

Cisco Extensible Provisioning and Operations Manager 4.5

Industrial Computers. (Bulletin Number 6155) Product Data and Installation Instructions. Allen-Bradley Drives

Traffic Offload. Cisco 7200/Cisco 7500 APPLICATION NOTE

VOICE/DATA SIMCARD USA UNLIMITED

Installation Instructions

ALLEN-BRADLEY. Allen-Bradley. User Manual. Dataliner DL5 Series Off-line Programming Software. (Cat. No NP5)

ENHANCED INTERIOR GATEWAY ROUTING PROTOCOL STUB ROUTER FUNCTIONALITY

CISCO IP PHONE 7970G NEW! CISCO IP PHONE 7905G AND 7912G XML

Vodafone Usage Manager R2.0

PLEASE NOTE: firms may submit one set of research questionnaires covering both China and Hong Kong or separate sets for each jurisdiction

DATA APPENDIX. Real Exchange Rate Movements and the Relative Price of Nontraded Goods Caroline M. Betts and Timothy J. Kehoe

Cisco 3745 Gateway - PBX Interoperability: Avaya Definity G3 PBX using Q.931 PRI Network Side Interfaces to an H.323 Gateway

Allen-Bradley. Smart Self-powered Serial Converter. User Manual. Cat. No SSS Firmware 1.xx

CISCO 7304 SERIES ROUTER PORT ADAPTER CARRIER CARD

Cisco 2651XM Gateway - PBX Interoperability: Avaya Definity G3 PBX using Analog FXO Interfaces to an H.323 Gateway

NEW CISCO IOS SOFTWARE RELEASE 12.2(25)EY FOR CISCO CATALYST 3750 METRO SERIES SWITCHES

Griffin Training Manual Address Maintenance

NEW METHOD FOR ORDERING CISCO 1700 SERIES MODULAR ACCESS ROUTERS AND CISCO 1800 SERIES INTEGRATED SERVICES ROUTERS SOFTWARE SPARE IMAGES

Global entertainment and media outlook Explore the content and tools

Out of Bundle Vodafone

E-Seminar. Voice over IP. Internet Technical Solution Seminar

(catalog no KTCT)

Alternative phone number: Credit card/debit card number Expiry date: / / DD MM YYYY

ANNOUNCING NEW PRODUCT OFFERINGS FOR THE CISCO CATALYST 6500 SERIES

Cisco ONS SDH 12-Port STM-1 Electrical Interface Card

Quintiles vdesk Welcome Guide

THE POWER OF A STRONG PARTNERSHIP.

Digital EAGLEs. Outlook and perspectives

Cisco Catalyst 2950 Series Software Feature Comparison Standard Image (SI) and Enhanced Image (EI) Feature Comparison

Beckhoff short profile

END-OF-SALE AND END-OF-LIFE ANNOUNCEMENT FOR THE CISCO FLEXWAN MODULE FOR USE WITH THE CISCO 7600 SERIES ROUTERS AND CATALYST 6500 SERIES SWITCHES

CONFIGURING EPOLICY ORCHESTRATOR 3.0 AND MCAFEE 8.0i WITH CISCO CALLMANAGER

MULTI-VRF AND IP MULTICAST

User Guide. Introduction

Power Performance Flexibility Integrated Servo and Control Solutions. ULTRA Plus Positioning Servo Drives. AB Drives

Shell Global Helpline - Telephone Numbers

Turquoise Terminal Returns User Guide for Creating & Uploading a Turquoise Terminal Return

Cisco Unified CallManager 4.0-PBX Interoperability: Mitel 3300 ICP Release 4.1 PBX to a Cisco 6608 Gateway using T1 QSIG with MGCP

Field Terminal Assembly (FTA)

Cisco AS5300 Gateway - PBX Interoperability: NEC NEAX 2400 PBX using T1 PRI Interfaces to an H.323 Gateway

Cisco CallManager Server Upgrade Program

7. Parts catalog. How to use this parts catalog xx. Abbreviations used in the parts catalog include the following:

Cisco Unified CallConnector for Microsoft Office Quick Reference Guide 1

High-Availability Solutions for SIP Enabled Voice-over-IP Networks

USING TREND SERVERPROTECT5 WITH CISCO CALLMANAGER

Appendix G. Percentiles and Standard Deviations of Science Achievement TIMSS 2011 INTERNATIONAL RESULTS IN SCIENCE APPENDIX G 495

NEW JERSEY S HIGHER EDUCATION NETWORK (NJEDGE.NET), AN IP-VPN CASE STUDY

CISCO SFP OPTICS FOR PACKET-OVER-SONET/SDH AND ATM APPLICATIONS

CISCO 7304 SERIES ROUTER PORT ADAPTER CARRIER CARD

Using TAPS with +E.164 Directory Numbers

OPERATIONS MANUAL Audio Conferencing

Payphone Origination Service Charge Rate Per Min. Mobile Origination Service Charge. MLB Switched Rate Per Min. MLB Dedicated Rate Per Min

Patent Portfolio Overview May The data in this presentation is current as of this date.

A Guide to our Tariffs

For: Ministry of Education From Date: 19 November 18-2 December 18 Venue: M1 Shops

Introducing Cisco Catalyst 4500 Series Supervisor Engine II-Plus-10GE and Cisco Catalyst 4500 Series 48-Port 100BASE-X SFP Line Card

The Traveller plans include a monthly Mobile Broadband allowance to be used within all Table 1: Go Europe + USA Destinations.

THE CISCO SUCCESS BUILDER PROGRAM THE CISCO SMALL OFFICE COMMUNICATIONS CENTER: AFFORDABLE, PROVEN COMMUNICATIONS SOLUTIONS FOR SMALL ORGANIZATIONS

3M Volition Network Solutions

CISCO FAX SERVER. Figure 1. Example Deployment Scenario. The Cisco Fax Server solution consists of the following components:

Step 1: New Portal User User ID Created Using IdentityIQ (IIQ)

COCAINE (unless otherwise noted) amongst young people (ordered alphabetically by regions)

CISCO NETWORK CONNECTIVITY CENTER BUSINESS DASHBOARD

Cisco MDS 9000 Family and EMC ECC Integration

A Guide to our Tariffs

Installation Instructions

Cisco HCS Country Dial Plans

Strategic IT Plan Improves NYCHA Resident Services While Reducing Costs US$150 Million

Power Analyzer Firmware Update Utility Version Software Release Notes

Transcription:

Document Update Setting Up a DH485 Network of (Bulletin 2750) intelligent Antennas Using a 27601RB Module and 2760=SFC2 Protocol Cartridge Overview This document provides instructions on interfacing the 2750 Intelligent Antenna (DH485 MultiDrop) using the 2760SFC2 Series A, Revision B protocol cartridge. This information covers the following catalog numbers: Catalog No. 2750AH, AHD, AHP and AHPR. These instructions provide supplemental configuration information as described in Publication 2750NDOOl. It is meant as a replacement to Chapter 5, Setting Up a DH485 Network (Pages 517 to 520) and Chapter 7, IDP (Antenna) Commands, (Pages 7l to 77). Refer to Publication 2750ND001 for additional setup information as needed. The AllenBradley 2750AH series Intelligent Antennas transfer information between an RF (Radio Frequency) tag and host(s) on a DH485 network through the Flexible Interfaces Module (Catalog No. 2760RB). The antennas operate as slave devices on the network and respond to commands and requests for data from a computer or PLC@ on the network. the antennas communicate with RF tags through bidirectional tags. Hardware Requirements Implementation of the procedures described in this application note require the following hardware: AllenBradley Bulletin 2750AH Series Intelligent Antennas Bulletin 2760RB, Flexible Interface Module Bulletin 2760SFC2, Series A, Revision B, protocol cartridge Related Publications This document refers to the following publications, which should be available for reference while working through this application note: Publication Number 2750ND001 2760ND001 2760ND002 2760822 Title Bulletin 2750 Intelligent Antenna (DH485 MultiDrop) (Catalog No. 2750AH, AHD, AHP, and AHPR) User Manual, Bulletin 2760 Flexible Interface Module (Catalog No. 276038) Bulletin 2760 DFIIASCII Protocol Cartridge User Manual Bulletin 2760 FE485 LAN Master/Slave Protocol Cartridge 2750NDOOlDlJl November1995

2 Chapter 5. Setting Up a DH485 Network of Antennas 6a. Set Factory Defaults This section shows bow to set the Flexible Interface Module and device ports to their factory defaults. A default configuration is downloaded to each port. 1. Select menu option YOB to set the device ports to the factory defaults. 2760RB SERIES x REVISION x \ COPYRIGHT 1969 ALLENBRADLEY COMPANY, INC. 1X CONFIGURATION PARAMETERS 2X IDENTlFlCATlON NUMBERS 3 DEVICE PORT PROTOCOL NAMES 4DM MATCH CODE ENTRIES 51 DISCRETE BYTE INPUT ENTRIES 6 THE DATA MATRIX ENTRIES 7 THE PASS THROUGH ENTRIES 8 NONVOLATILE SCRATCH PAD AREA SXF RB MODULE FUNCTIONS AX HARDWARE DIAGNOSTICS BX SOFTWARE DIAGNOSTICS C EXIT CONFlGURATlON MODE WHERE X (0 TO 7) AND D (1 TO 3) ARE PORT NUMBERS WHICH ARE DEFINED BELOW : 0 RB CMMND PRCSS 2 SERIAL PORT 2 4 CONFIG PORT 6 l/o RACK SLT 1 1 SERIAL PORT 1 3 SERIAL PORT 3 5 l/o RACK SLT 0 7 RESERVED WHERE F (A TO E) ARE FUNCTIONS THAT RB CAN PERFORM WHICH ARE DEFINED BELOW : A RESET B SET DEFAULTS C FLUSH D INITIAUZE E CLEAR DIAGS WHERE M (A TOT) AND I (A TO H) ARE ENTRY NUMBERS FOR THE SELECTION MADE ABOVE. ENTER A MAIN MENU SELECTION: 9OB [RETURN] You exit the configuration mode and the screen displays: EXIT 2760~RB MODULE CONFIGURATION The device ports are automatically set to their default settings. All of the module LED indicators turn red. Within a short time, the device port LEDs turn green, the configuration port LED turns green, and the ACTIVE/FAULT LED flashes green. 2. Send a Break to reenter the configuration mode and the main menu. Note: The Break sequence can be sent using key combinations from your terminal or terminal emulator. See your terminal emulator user manual. For ProComm@, the Break is sent by holding down the [Alt] key and pressing [B]. 2750NDOOtDUl November 1995

3 6b. Verify Factory Defaults Verify that the factory defaults are set for port 1. 1. Select menu option [3] Device Port Protocol Names to verify that DH485 protocol is assigned to port 1. Select 2760~SFC2 DH48.5 ENTER A MAIN MENU SELECTION: 3 [RETURN] PORT 1 = COPYRIGHT 1991,199O ALLENBRADLEY COMPANY, INC. 2760~SFC2 DH465, SERIES A, REVISION B (YES/NO) = YES. PORT 2 = COPYRIGHT 1991,199O ALLENBRADLEY COMPANY, INC. 2760SFC2 DT, SERIES A, REVISION B (YES/NO) = YES. PORT 3 = COPYRIGHT 1991,199O ALLENBRADLEY COMPANY, INC. 2760SFC2 DH465, SERIES A, REVISION B (YES/NO) = YES. EDIT THIS SELECTION (YES/NO)? 2. The listing should show DH485 for port 1. Enter [N] to return to the main menu. Note: If another protocol is assigned to port 1, make sure the 2760SFC2 cartridge is the only cartridge in the module and select menu option 90B to set the device ports to their factory defaults. Select menu option 3 again. The listing should appear as the one above. Note: Any of the three network ports on the 2760RB, ports 1,2, or 3 can be used to communicate with the intelligent antennas. 3. Select menu option [2] Zdentification Numbers to identify the network of devices to operate on port 1. Select RS485 LAN OTHER SLAVE DEVICES. 2750NDOOlDUl November 1995

4 ENTER A MAIN MENU SELECTION: 2 [RETURN] CATEGORY 1 ASCII DEVICES (275%DM6/9)0h, (YES/NO) = YES =? N[RETURN] EDIT THIS SELECTION? Y [RETURN] CATEGORY 1 ASCII DEVICES (2755DM6/9)1 h, (YES/NO) YES =? N[RETURN] CATEGORY 1 PCCC DEVICES (2755DM6/9)lh, (YES/NO) = YES =? N[RETURN] CATEGORY 1 IDP DEVICES (2750AH)2h, (YES/NO) = YES =? N[RETURN] RS485 IAN OTHER SLAVE DEVICES = YES This network requires category 1 slave devices on the link using IDP protocol. The 2750AH antenna is a slave that uses IDP protocol. The Flexible Interface Module port operates as a master to all antennas on the network. 6c. Activate Polling of Nodes This section shows how to activate automatic polling of nodes 4 and 5 on the network. All data the module receives from nodes 4 and 5 is sent to the PLC using block transfers. 1. Select option II Confgwation Parameters from the main menu. The parameters you need to modify are flagged by arrows. SLOT TIME (NO. CHARS) (DEC 0...255) = 7. INTERCHAR TIME (NO. CHARS.) (DEC 0...255) = 7 IDLE TIME (NO. CHARS) (DEC 0...255) = 3. RETRIES (DEC 0...255) 3. 19200 BITS PER SECOND (YES/NO) = YES. BCD NODE NUMBERS (ENABLE/DISABLE) = ENABLE. BYTE SWAPPING (ENABLE/DISABLE) = ENABLE. RECEIVE MATRIXING (ENABLE/DISABLE) = DISABLE. MATRIX ADDRESS (HEX 0...#I)) = 0. REESTABLISH FREQUENCY (DEC 0...255) = 5. POLL FREQUENCY/DESTINATION [O] (HEX 0...mr) = 5. POLL FREQUENCY/DESTINATION [I] (HEX 0...ffflj = 5. POLL FREQUENCY/DESTINATION [2] (HEX 0...ffftj = 5. POLL FREQUENCY/DESTINATION [3] (HEX 0...mr) = 5. POLL FREQUENCY/DESTINATION [4] (HEX 0...ffltJ = 5. POLL FREQUENCY/DESTINATION [5] (HEX 0.Jftf) = 5. POLL FREQUENCY/DESTINATION [S] (HEX 0...mr) = 5. POLL FREQUENCY/DESTINATION m (HEX 0.,.fHf) = 5. POLL FREQUENCY/DESTINATION [9] (HEX 0...ffftj = 5. POLL FREQUENCY/DESTINATION [lo] (HEX 0...mr) = 5. CONTINUE THIS SELECTION (YES/NO)? N [RETURN] 2750NDOOlDUl November 1995

5 2. Enter N (As shown above) to discontinue the display. EDIT THIS SEL~ON m/no)? Y[RETURN] 3. Enter Y at the next prompt (As shown above) to edit the selection. Questions then display line by line for each node. 4. Enter [RETURN] until the prompt for the node 4 polling frequency is displayed. Then enter 105 and [RETURN] to activate automatic polling for node 4. The value 105 means the module will poll node 4 for data every polling cycle. POLL FREQUENCY/DESTINATION [0] (HEX 0...ffffJ = 5 POLL FREQUENCYlDEsTINATION [I] (HEX 0...ffB) = 5 POLL FREQUENCY/DESTINA~ON [2] (HEX 0...ffW) = 5 POLL FREQUENCY/DESTINATION [3] (HEX 0...ffff) = 5 POLL FREQUENCY/DESTINATION [4] (HEX 0...ffff) = 105 5. Enter 105 and [RETURN] to activate automatic polling for node 5. I POLL FREQUENCY/DESTINATION [5] (HEX 0...ffff) = 105 6. Enter SAVE and [RETURN] at the next question to save the changes and return to the main menu. POLL FREQUENCY/DESTINATION [6] (HEX 0...ff@ = 5 SAVE [RETURN] PRESS THE REfNRN KEY To CONTINUE. 7. Exit Configuration Mode Now that the module and port 1 are configured, you can exit the configuration mode. Select menu option C Exit Configuration menu and configuration mode. Mode to exit the main 2750NDOOlDUl November1995

6 Chapter 7 IDP (Antenna) Commands Modified for 2760=RB with 27604FC2, Series A, Revision B Chapter Objectives This chapter defines the commands that can be used to operate the antenna when using DH485 protocol. This chapter includes: Description Description of the general format of commands of the general format of antenna response Example coding, and discussion of command parameters Example antenna responses to commands Command Format Appendix C provides an overview of the DH485 protocol. Most of DH485 network functions are handled automatically by the Flexible Interface Module. The figure below shows the format of commands when communicating with an antenna on a DH485 network using the Flexible Interface Module. Figure 7.1 Antenna Command Format (PLC/Flexible Interface Module Host) Word MSB LSB We 0 Byte Count 1 WC Port DST Port I Flexible Interface Module/PLC Parameters LSAP* NODE OH495 Parameters Command Repeat Cnt 00 00 a Sequence No. 10 Sensor No. 12 IDP Protocol Parameters Data (0...112 bytes) 14 i28 Note: The size of the command is limited to 64 words. This is the maximum size of a PLC Block Transfer. * For RFDH485, the LSAP is always 80 HEX. 2750NDOOlDUl November 1995

7 A host device on the network must provide the following data with each antenna command: Byte Count (PLCs Only) This Binary Coded Decimal (BCD) indicates the&umber of bytes in a message including word 0. Port 5 of the Flexible Interface Module (used for PLC communications) adds the byte count to the message before sending it to another port. The Flexible Interface Module removes the byte count before block transferring the message to the PLC. Source Port # (SRC Port) The number of the Flexible Interface Module port (0 to 7) sending the message. Destination Port # (DST Port) The number of the Flexible Interface Module port (0 to 7) receiving the message. Node # The node (0 to 31) in the network which receives the message. Source LSAP (SRC LSAP) The communication address of the node sending the message. The 2750AH antenna uses the LSAP of 128 (80 HEX) to read, write or configure tag data. Use LSAP 00 for network communications diagnostics. Repeat Count performed. The number of times the command is to be Command (CMD) The IDP command function to be performed. Set this byte to the appropriate hex code for the desired command. See Table 7.A. Sequence No. A unique number (supplied by host) that associates an antenna reply with a command. The antenna will return the same value with the reply message. Sensor No. The high and low bytes are always set to 00. Data The data field is used with the following commands: Echo Command (Data to be echoed) Peform Command Read and/or write descriptors. Use the Perform command to cause the antenna to perform tag reads and writes, by using that command s data field to code read and write transaction descriptors. See Perform Command and also Sensor Program descriptions in this Chapter. Set/Get configuration commands. commands Refer to individual 2750NDOOlDUl November 1995

8 Table 1.A Command Codes and Descriptions Command Code Command Descriptions Echo Interface 01 This command sends data to the antenna s host interface processor; data is returned to the host unchanged. Use this command to test the communications link between host and antenna. Echo Sensor Interface and Sensor Diagnostics Sensor Diagnostics 11 02 12 This command sends data to the antenna s sensor processor; data is returned to the host unchanged. Use this command to check the antenna internal RAM swapping. This command causes the antenna to run diagnostics on both the host interface and sensor processor. Returned results are coded in six data bytes. This command causes the antenna to run diagnostics on the sensor processor. Results are returned in a two byte data field. Reset 03 This command causes the antenna host interface and sensor processors to reinitialize and start running again with default configuration. Sensor defaults to settings from the last sensor configuration command. Get Interface Configuration 04 This command will get the current configuration settings of the host interface. Configuration returned in the data field includes DIP switch settings. Get Sensor Configuration 06 This command causes antenna to return its working parameters, such as tag type, object detect and timeout. Some parameters (revision number and technology type) are reserved, read only. Set Sensor Configuration 07 This command sets the antenna working parameters. Read only fields are ignored and should be set to zero. Perform 08 This command will cause the antenna to execute the sensor program sent to it as many times as is indicated by the repeat count. Sensor program includes tag read and/or write command descriptor(s). Antenna Response Format The antenna returns a response to each command from the host (except the Reset command). Response information is contained in the first 8 bytes of the antenna s IDP response. Responses to the following commands return a data field: Echo (data returned). Perform Read or Write Tag Transactions. Get Interface Configuration (configuration returned). Get Sensor Configuration (configuration returned). Diagnostics. 2750NDOOlDUl November 1995

9 Refer to the figure below and response field descriptions follow: which Figure 7.2 Antenna Response Format Word MS6 LSB Byte Count Byte 0 SRC Port DST Port 2 LSAP NODE 4 Response Code Return Code 6 Interface Sk Sensor Sts 0 5 Sequence No. IO Sensor No. 12 Data 14 (0...112 bytes) 128 Response Code The response code returns the same command code as the antenna command code, except 80 Hex is added. For example: If the command code is 0 1, the response code will be 8 1; if the command code is 12, the response code is 92, etc. 2750NDOOlDUl November 1995

10 Return Code This field contains a code indicating the success or failure status of the command execution. The table below lists the return codes. Table I.6 Antenna Command Return Codes Bit Set I Meaning 1 1 Invalid command 2 1 Command execution unsuccessful 4 1 Command format error. see Note 2, below 6 Never returned set 16 Never returned set 5 Never returned set 6 Never returned set 7 Error (set if any other bits are set) No bits set I Success Note 1: More than one bit can be set. Note 2: A command format error is returned for the following: Length in Sensor Program not equal to actual length of Data field. Length of command header and data (if any) not as expected by antenna (header information or data lost). Host Interface Status This field contains a code indicating host interface processor status. The table below. Table 1.C Host Interface Status Bit Set Meaning 0 Internal interface fault 1 Host communications failure 2 Never returned set 3 Never returned set 4 Never returned set Note 1: More than one bit can be set. 2750NDOOlDUl November 1995

11 Sensor Interface Status This field contains a code indicating the status of the sensor interface processor. The table below lists the status codes. Table l.d Sensor Interface Status Interface to sensor communications failure The data buffer of the sensor has overflowed 3 Never returned set 4 Never returned set 5 Never returned set 6 Never returned set 7 I Never returned set No bits set Normal status Note 1: More than one bit can be set. Sequence Number Unchanged (Same as in command). Sensor Number 00 00 (Same as in command). Data Field The data field is padded by the Interface Processor so that an even number of bytes are sent in responses. Data is dependent of type of command. See Perform, Echo, and Get Configuration Commands for response data descriptions. 2750NDOOlDUl November1995

12 Applying IDP Commands Figures 7.3 and 7.4 illustrate how the Flexible Interface Module handles data as it is transferred between devices on a DH485 network: Figure 7.3 shows how an IDP command is transferred from a PLC to an antenna on the DH485 network. Figure 7.4 shows how IDP data is transferred from an antenna to a PLC on the DH485 network. Figure 7.3 IDP Data from PLC to Antenna From PLC I Port 5 Byte Count SIX Port LSAP CMD DST Port NODE Repeat Count Port 5 \ Removes 1 ByieCount 1 I Antenna Data IDP Protocol CMD I Repeat Count I I 00 00 Sequence No., LSB Sequence No., MSB Sensor No., LSB Sensor No., MSB Data 1 Data 0 Data 3 Data 2 Port1,2or3 Removes I Sensor No., LSB I SIX Port DST Port SW Node DST Node / SRC LSAP DST LSAP i I Data 0 I I Data 1 I \_\_ J 2750NDOOlDUl November 1995

13 Set Configuration Example Using the 2760~RB and the 2760~SFC2 Cartridge PLC DATA TABLE LSB MSB SRC Port LSAP = 80 Hex DST Port Node 07 00 00 00 11 11 00 I 00 00 I 00 00 Tag Type * 00 I 00 00 I 01 * Note: See Publication 2750NDOOI, Page 7I 7 for information on Tag Type. 2750NDOOlDUl November1995

14 Notes: 2750NDOOlDUl November 1995

15 Notes: 2750NDOOlDUl November 1995

PLC is a registered trademarks of AllenBradley Co., Inc., a Rockwell International Company Procomm is a registered trademark of Datastorm Technologies, Inc. #? ROC~WW Automation AllenBradley, a Rockwell automation business, has been helping its customers improve productivity and quality for more than 90 years. We design, manufacture and support a broad range of automation products worldwide. They include logic processors, power and motion control devices, operator interfaces, sensors and a variety of software. Rockwell is one of the worlds leading technology companies. Worldwide representation. Argentina * Australia Austria Bahrain Belgium Brazil Bulgaria Canada Chile China, PRC Colombia Costa Rica Croatia Cyprus Czech Republic * Denmark Ecuador Egypt El Salvador Finland * France Germany Greece Guatemala Honduras Hong Kong Hungary Iceland India Indonesia Ireland Israel Italy Jamaica Japan Jordan Korea Kuwait Lebanon Malaysia * Mexico Netherlands New Zealand * Norway Pakistan Peru Philippines Poland Portugal Puerto Rico Qatar Romania * RussiaC& Saudi Arabia Singapore Slovakia * Slovenia South Africa, Republic Spain Sweden Switzerland * Taiwan Thailand Turkey United Arab Emirates United Kingdom United States Uruguay Venezuela Yugoslavia AllenBradley Headquarters, 1201 South Second Street, Milwaukee, WI 53204 USA, Tel: (1) 414 3822000 Fax: (1) 414 3824444 2750NDOOlDUl November 1995