4D Magnetic Resonance Analysis. MR 4D Flow. Visualization and Quantification of Aortic Blood Flow

Similar documents
QAngio XA 7.3. Quick Start Manual. July 31, v6.0

Vessel Explorer: a tool for quantitative measurements in CT and MR angiography

4D MRI phase-contrast image to determinate blood flow patterns in aorta

Blood Particle Trajectories in Phase-Contrast-MRI as Minimal Paths Computed with Anisotropic Fast Marching

Veterinary Solutions without Compromise

CPM Specifications Document Healthy Vertebral:

Estimating Arterial Wall Shear Stress 1

INSPIRED BY YOUR PATIENTS.

The VesselGlyph: Focus & Context Visualization in CT-Angiography

High dynamic range magnetic resonance flow imaging in the abdomen

Clinical Importance. Aortic Stenosis. Aortic Regurgitation. Ultrasound vs. MRI. Carotid Artery Stenosis

Adaptive Animations of Vortex Flow Extracted from Cardiac 4D PC-MRI Data

GE Healthcare. Vivid 7 Dimension 08 Cardiovascular ultrasound system

Medis Suite 3.0. Quick Start Manual. October 6, v3.0

4DM Packages. 4DM Packages & License Types. Information to help you order the appropriate licenses for your site.

11/18/ CPT Preauthorization Groupings Effective January 1, Computerized Tomography (CT) Abdomen 6. CPT Description SEGR CT01

7D Cardiac Flow MRI: Techniques & Automation of Reconstruction

Automated segmentation methods for liver analysis in oncology applications

NUMERICAL STUDY OF BLOOD FLOW IN A VESSEL WITH INCREASING DEGREE OF STENOSIS USING DYNAMIC MESHES

Skåne University Hospital Lund, Lund, Sweden 2 Deparment of Numerical Analysis, Centre for Mathematical Sciences, Lund University, Lund, Sweden

Automatic Ascending Aorta Detection in CTA Datasets

Dedicated Software for Bifurcation QCA: Pie Medical (CAAS 5.9) and MEDIS (QAngio XA ) Validation on Phantom analysis

MR Advance Techniques. Vascular Imaging. Class III

Magnetic Resonance Elastography (MRE) of Liver Disease

Isogeometric Analysis of Fluid-Structure Interaction

ThE ultimate, INTuITIVE Mr INTErFAcE

High Performance without Compromise. Cardiovascular. MyLab30

QFlow 5.6. User Manual. February 18, v1c0

Virtual Phantoms for IGRT QA

From medical imaging to numerical simulations

CFD simulations of blood flow through abdominal part of aorta

Optimization of Flow Diverter Treatment for a Patient-specific Giant Aneurysm Using STAR-CCM+ László Daróczy, Philipp Berg, Gábor Janiga

A Workflow for Computational Fluid Dynamics Simulations using Patient-Specific Aortic Models

Future is Effortless

BioIRC solutions. CFDVasc manual

Ultrasound. Q-Station software. Streamlined workflow solutions. Philips Q-Station ultrasound workspace software

Resona 7. New Waves in Ultrasound Innovation. Premium Ultrasound System

BUZZ - DIGITAL OR WHITEPAPER

The Latest Technology. Digi-Lite TM Key Features & Benefits

Chapter 11: Time Dependent Analysis(TDA) for Flow Analysis

Automatic Segmentation of the Aortic Dissection Membrane from 3D CTA Images

Applying vessel inlet/outlet conditions to patientspecific models embedded in Cartesian grids

USAGE PROFILES FOR SYSTEM REQUIREMENTS

Visualization and Quantification of Helical Flow in the Aorta using 4D Flow MRI

OBJECT MANAGEMENT OBJECT MANIPULATION

The Advanced Neuro MR Processing & Visualization Solution

Magnetic Resonance Imaging Velocity. Information. Joe Lee. April 4, 2000

A NEW LASER FOCUS ON PATIENT SAFETY

8. Tensor Field Visualization

997-10, Daechi-dong, Gangnam-gu, Seoul, , Korea Tel: Fax:

Analysis of Cerebral Blood Flow from Small Rodents

Resona 7. Premium Ultrasound System. New Waves in Ultrasound Innovation

Time-resolved Volumetric MRI Blood Flow A Doppler Ultrasound Perspective

3D Volume Mesh Generation of Human Organs Using Surface Geometries Created from the Visible Human Data Set

Tutorial School on Fluid Dynamics: Topics in Turbulence May 24-28, 2010

Family of Diagnostic and Therapeutic Catheters

Linköping University Post Print. Phase Based Level Set Segmentation of Blood Vessels

Life Sciences Applications: Modeling and Simulation for Biomedical Device Design SGC 2013

Dosimetric Analysis Report

Automatic Quantification of DTI Parameters along Fiber Bundles

LASER SOLUTIONS. Ensure Accurate Setup from Simulation to Treatment. MOVEABLE: CT SIM+ // FIXED: MICRO and MICRO+

Analysis of CMR images within an integrated healthcare framework for remote monitoring

GE Healthcare. AppsLinq* remote courses catalogue

Case TAVR080: Aortic Valve Step-by-Step Guide

Modeling Evaporating Liquid Spray

Optimised Computational Functional Imaging for Arteries

Abstract Submission Instructions

Automatic Quantification of DTI Parameters along Fiber Bundles

arxiv: v2 [cs.cv] 28 Jan 2019

Modeling Evaporating Liquid Spray

Modeling and preoperative planning for kidney surgery

Human Heart Coronary Arteries Segmentation

Ultrasound To Go. MySono U5

DICOM Conformance Statement

Automated segmentation of blood-flow regions in large thoracic arteries using 3D-cine PC-MRI measurements

Beyond PACS. From the Radiological Imaging Archive to the Medical Imaging Global Repository. Patricio Ledesma Project Manager

Probabilistic Tracking and Model-based Segmentation of 3D Tubular Structures

GE Healthcare. Vivid E9 XDclear. with

High dynamic range fusion of magnetic resonance flow imaging data

Accuracy of Computational Hemodynamics in Complex Arterial Geometries Reconstructed from Magnetic Resonance Imaging

Philips Medical Systems DICOM Conformance Statement. EasyWeb 2.0. Document Number April 1999

Optimised Computational Functional Imaging for Arteries

Modeling Mitral Valve Leaflets from Three-Dimensional Ultrasound

QMass 8.1. Quick Start Manual. June 13, v2.0

Outline: Contrast-enhanced MRA

Image Analysis, Geometrical Modelling and Image Synthesis for 3D Medical Imaging

midas NFX 2017R1 Release Note

VIEW PRO 4D. four dimensions in one workstation

VieW 3D. 3D Post-Processing WorKstation THE THIRD DIMENSION. Version 3.1

APLIO JUST GOT EVEN BETTER INTRODUCING THE INNOVATION 2016 UPGRADE

Image-based simulation of the human thorax for cardio-pulmonary applications

Integrated proton-photon treatment planning

Multimodality Imaging for Tumor Volume Definition in Radiation Oncology

Qualitative Comparison of Conventional and Oblique MRI for Detection of Herniated Spinal Discs

New Technology Allows Multiple Image Contrasts in a Single Scan

What s new in. teamplay? Discover the latest features and functionalities. siemens.com/teamplay

QMass MR 7.6. Release Notes. February 24, v1c0

Robot-assisted MRI-guided prostate biopsy using 3D Slicer

Using TeraRecon intuition Viewer with STAT Quick Reference Guide

Lecture 6: Medical imaging and image-guided interventions

Transcription:

4D Magnetic Resonance Analysis MR 4D Flow Visualization and Quantification of Aortic Blood Flow

4D Magnetic Resonance Analysis Complete assesment of your MR 4D Flow data Time-efficient and intuitive analysis of your 3D phase contrast MR Nowadays a lot of research on valvular disease is based on 3D phase contrast MR images. CAAS MR 4D Flow is specifically designed to extract relevant information from the 3D phase contrast MR images, within a few clicks. Automatic 3D segmentation of the data provides interactive visualization of flow patterns by means of streamlines, time-resolved path lines and color coded vectors. Parameters for Flow comparison Compare different planes in the aorta or different datasets by 2D flow and Wall Shear Stress parameters, provided by the software. Segmentation CAAS MR 4D Flow enables you to construct a 3D Volume of the cardiovascular structure that can be visualized interactively. You can turn, pan and adjust opacity of the 3D anatomical structure for easy visualization. A centerline, for planar visualization and quantification, can automatically be defined by just one click in the ascending and one click in the descending aorta. The provided workflow guides you through the software for easy and fast analysis of your dataset. Mesh edit of 3D Model 3D volume with centerline

Visualization CAAS MR 4D Flow provides multiple options for visualization of blood flow. Through interactive point and click, multiple emitter planes can be placed along the centerline. Originating from multiple and freely selectable emitter planes, aortic flow can be visualized by streamlines, time-resolved 3D pathlines or as color coded vectors. Streamline visualization Vector fields from three emitter planes Wall Shear Stress 1 Compare different planes within a dataset by measuring the wall shear stress (WSS). The distribution of the wall shear stress will be presented in a 3D color coded model. By placing multiple planes in the 3D model, local values of wall shear stress are represented by pie charts. WSS within aneurism (ascending aorta) Wall shear stress distribution and representation in pie charts Corresponding streamlines within aneurism (ascending aorta) 1 Wall Shear Stress and Pressure Difference analysis are for research use only and not meant for clinical decision support.

2D Flow Parameters A 2D flow phase contrast analysis in the 3D volume can be performed in just a few clicks. You can freely place multiple planes throughout the aorta for 2D velocity analyses. Using the phase contrast and magnitude images, a 2D vessel contour is automatically detected which can be manually corrected. Contours can be automatically propagated to calculate results over time. Basic 2D flow parameters are presented in a graph. 2D Flow parameters from multiple planes Pressure Difference 1 CAAS MR 4D flow calculates pressure difference between a reference and an obstruction plane. The pressure difference between the reference and obstruction plane is depicted by a color coded pressure map. The color coded pressure map will help in visualization of altered intraluminal pressures along the vessel. Pressure difference in an aortic stenosis 1 Wall Shear Stress and Pressure Difference analysis are for research use only and not meant for clinical decision support.

4D Magnetic Resonance Analysis Pie Medical Imaging, manufacturer of Quantitative Analysis software for cardiology and radiology, is well known for its CAAS product line. The CAAS software supports medical professionals in the diagnostic process and during patient treatment. Furthermore, CAAS is used in research studies on the efficacy of novel intervention methods. In CAAS MR 4D Flow, you can visualize 3D phase contrast image datasets and extract relevant blood flow parameters. Visualization of Blood Flow > Visualize blood flow through streamlines > Dynamic visualization with time-resolved pathlines > Visualization of color coded vectors from one or multiple emitter planes Blood Flow parameters > Wall shear stress in a 3D model > 2D flow parameters of blood velocity at any arbitrary plane in the aorta SMS2227 2.0

Pie Medical Imaging stands for: > The gold standard in Quantitative Analysis software > Extensive validation for both patient care and research > Accurate and reproducible analysis results > Fast and intuitive operation > Expertise in cardiovascular quantitative analysis software Quality Assurance: Pie Medical Imaging develops, produces and sells products in accordance with international accepted standards. CAAS MR 4D Flow is CE marked and pending 510(k) clearance and therefore meant for research purposes only in the US. Quality Management System complies with: > ISO 13485 > Canadian CAN/CSA ISO 13485 Pie Medical Imaging BV Philipsweg 1 6227 AJ Maastricht P.O. Box 1132 6201 BC Maastricht The Netherlands tel +31 (0)43 328 13 28 fax +31 (0)43 328 13 29 mail pmi@pie.nl web www.piemedicalimaging.com