Vandal-resistant entrance panel. Installer manual RA00054AA_I_EN01PC-12W16

Similar documents
Vandal-resistant entrance panel

Sfera Display Module. Installer manual 05/16-01 PC

D45 System. Digital colour entrance panel with addresses list

2 WIRE Video Door Entry system

05/16-01 PC Monobloc Audio Digital Entrance Panel. Installer manual

TiMonoblocEntrancePanel

Lens of the access control (Optional) Camera: pick up the image. PP NN TS : configurator. ISP: entrance panel software upgrade connector

Sfera Keypad Module. Installer manual 07/12-01 PC

TiSferaDesign. Instructions for use.

Video Display Eteris. Installation manual 01GF-28W10

item Instruction sheet PART. T6101D - 05/05-01 PC

D45 System. 3.5 Colour handsfree internal unit. Front view

VIDEO DOOR ENTRY SYSTEM OFFER

2 WIRE video door entry system

CLASSE 300 THE CONNECTED VIDEO INTERNAL UNIT

D45 System. 7 touch screen handsfree internal unit. Front & side views

PUSH BUTTON PANEL. SECTION 3A (Rev. B) SECTION CONTENTS. Download from Technical Manuals area. sec.3a

Video Display Eteris User guide 01GF-28W10

CATALOGUE D45 High performance door entry system

D45. High performance door entry system CATALOGUE A Group Brand

NEW. Bticino modular entrance panels. Sfera. CHOOSE YOUR FINISH Replace the dots in the Cat. No. with either 1, 2, or 3 to select the desired finish

VIDEO DOOR ENTRY SYSTEM OFFER

Front view. Internal view. Legend

Temperature control unit

F Installation manual.

Video Display. User guide 03/11-01 PC

8-wire Digital. Audio/Video Intercom Systems. Catalogue

EN TECHNICAL MANUAL. Mini door entry monitor with handset Art / Passion.Technology.Design.

ACTentry A5 Kit. ACTentry A5 Entry Panel. Audio Door Entry with Access Control. Audio Door Entry & Access Control Kit Features

HOMETOUCH HOMETOUCH flush mounted box Additional power supply. Rear view

EN TECHNICAL MANUAL. ViP Mini hands-free monitor art. 6721W. Passion.Technology.Design.

EN TECHNICAL MANUAL. Icona door entry monitor Art. 6601W - Art. 6601W/BM. Passion.Technology.Design.

MH201. Software Manual.

Classe 300. a STYLISH choice

TiSecurityPolyx user manual

1/6 SINGLE-FAMILY KIT WITH QUADRA AND MAXI. SB SYSTEM AWARDS KIT VIDEO QUADRA DOOR ENTRY SYSTEMS OVERVIEW HFX-9000M

New Kit Quadra ViP New Quadra ViP with Mini Audio Handsfree Wi-Fi

WALL MOUNTED PANEL. SECTION 2G (Rev.E) SECTION CONTENTS. Download from Technical Manuals area. sec.2g SMYLE WALL-MOUNTED PANEL 2

1/6 STAINLESS STEEL SBC DIG. 316 SENSE AUDIO ENT.PAN. 3ONE6 DOOR ENTRY SYSTEMS OVERVIEW 3451AS

FB00084-EN PROGRAMMING MANUAL DDVC/08 VR - DDC/08 VR

L4561N Stereo Control. Installation manual.

Video kit with 1 hands-free internal unit, surface-mounting. Video kit with 2 hands-free internal units, surface-mounting

EN TECHNICAL MANUAL. Handsfree door entry phone Mini 6750W, Mini 6751W. Passion.Technology.Design.

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

Mini ViP and WIRES THE MINI SERIES IS COMPLETED WITH THE NEW IP VERSIONS

Configuring a Net2 Entry Panel

F Basic gateway. Installation Manual.

User Manual. PCKeypad Wireless Keypad

EntraGuard Bronze. Quick Start Guide. Telephone Entry. 1.0 Specifications. 2.0 Unit Installation

Call Origination: Speaker/Mic: Camera: Mounting: Construction: Directory: Camera Aperture: Dimensions: Architects and Engineers Specification

INTERQUARTZ. Doorphone ID 201 Doorphone ID 202 Doorphone ID 204. User manual

Configuring a Net2 Touch Entry Panel

New one-family and two-family kits.

D1265. Installation Guide. Touchscreen Keypad

1/5 ICONA MONITOR, SBTOP AWARDS ICONA DOOR ENTRY SYSTEMS OVERVIEW 6601W

CLASSE 300 THE CONNECTED VIDEO INTERNAL UNIT

K44 Code lock. Technical manual

EN TECHNICAL MANUAL. Door-entry phone art. 2738W

DIGITAL 2 WIRE SYSTEM

DOOR ENTRY SYSTEM. ABB-Welcome Order catalogue

TiLocalDisplayNew. Software Manual 07/12-01 PC

AGATA C200 UK A/200N TARGHA 200. Installation Manual AGATAKIT C 200 UK

791/793 Easy Entry Keypads

Instructions manual. Software EVCom

1/5 MINI HANDSFREE MONITOR, SBTOP AWARDS MINI HANDSFREE VIDEO DOOR ENTRY SYSTEMS & KITS OVERVIEW 6721W

EN TECHNICAL MANUAL. Audio module Art and Art. 1622L

1/5 MINI HANDSFREE MONITOR, SBTOP AWARDS MINI HANDSFREE DOOR ENTRY SYSTEMS OVERVIEW 6721W

Smarther X8000-X8000W

1/5 MINI BLACK/WHITE MONITOR, SBTOP AWARDS OVERVIEW 6700W

PROJECT CREATE YOUR DESIGNS WITH

CM-110SK Standalone Keypad Installation Instructions

VIVO KIT. KIT VIDEO VIVO Code 97738EI V03_14. Page 2

D45 System - District generator

Product Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design)

CLASSE 300. Connected Video. Door Entry Systems

1 by Multi Video Intercom System Installation Guide

Installation Manual & User Instructions. MultiCom 500

Flatwall. Aesthetic value and functional integration for home automation

EN TECHNICAL MANUAL. Mini Hands-free door entry monitor Art. 6741W - Art. 6741W/BM. Passion.Technology.Design.

Digital Keypad Introduction

LE09268AA. Classe 300X. Door Entry Quick App support Guide manual.

Main menu. Camera/Door. Intercom. Playback. Do not disturb USER MANUAL VESTA2 GB2 MONITOR

INSTALLATION SHEET 791 and 793 Easy Entry Keypads

AlphaStatus Room Status System Installation and Use Instructions for the RSS400 Series Room Stations and Optional Master Station(s)

180 Series Keypad. Handbook. Revision 2.1

DK KIT. Quick Guide

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

Access Control for Houses 2 Wires Connection Doorline DR-200-SET Surface Mount Doorline DR-200-AV-SET Flush Mount

Nortel IP Phone 1120E/1140E User Guide (CICM).

VIDEOKIT IPVK/6296 SERIES IPVKC/6296 SERIES IP one way, two way videokit

New IP video door entry systems. A cutting edge welcome, always connected.

SHIED IP Camera RSCM-13601B/W

ACCESS CONTROL SYSTEM

D O O R S T A T I O N W I T H P R O X I M I T Y R E A D E R

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

Audio GSM module for modular plate

WELCOME. For customer support or any inquiries, please visit our web site at or contact us at

Access control panel U-Prox IC E (Elevator control)

BMSO1001. Virtual Configurator. User guide 01/10-01 PC

Installation Manual & User Instructions

Transcription:

308040 Vandal-resistant entrance panel Installer manual RA00054AA_I_EN01PC-12W16

2

Contents Vandal-resistant entrance panel 1 Introduction 4 1.1 Warnings and recommendations 4 1.2 What s in your box 4 2 Description 5 2.1 Front view 5 2.2 Back view 6 3 Installation 7 3.1 General rules for installation 7 3.2 Technical features 7 3.3 Dimensional data 8 3.4 Flush mounted installation 9 3.5 Wall mounted installation 9 3.6 Phisical configuration 10 3.7 Connections 11 3.8 Volume adjustment 11 3.9 Completing the installation 12 3.10 Installing the accessories 13 3.11 Camera lens and display glass replacement 14 4 Configuration using the keypad 15 4.1 Access to the configuration menu 15 4.2 If the password is forgotten 16 4.3 Language 16 4.4 Panel settings 17 4.5 Address book 21 4.6 Phonic module settings 26 4.7 FW versions 26 4.8 Access control settings 27 5 Configuration using the software 28 5.1 TiMonoblockEntrancePanel configuration software 28 5.2 Connection to the PC 28 6 Using the entrance panel 29 6.1 Calling residents 29 6.2 Call to the switchboard (only in multifamily configuration) 30 6.3 Call the only resident (Only in single family configuration) 31 6.4 Door lock release using a numerical code 32 6.5 Changing the lock code 33 Installer manual 3

1.1 Warnings and recommendations 1 Introduction Before proceeding with the installation we recommend that you read the content of this manual very carefully. The warranty will automatically become void in case of negligence, improper use, or tampering by unauthorised personnel. 1.2 What s in your box In your box you will find: Vandal-resistant entrance panel 308040 CD containing the Installer manual, as well as the configuration software with its user manual. 4

2 Description 2.1 Front view Vandal-resistant entrance panel Installer manual 14 13 12 11 1 2 3 10 4 5 9 8 7 6 1 - Loudspeaker 2 - Green LED: door open notification 3 - Microphone 4 - Display 5 - Key used to send the call to the selected resident, or to the switchboard 6 - Door lock release key 7 - Preset for VIGIK reader, or key lock release 8 - Delete key 9 - Alphanumeric keypad 10 - Resident search keys 11 - Green LED: call forwarded Red LED: system busy 12 - Green LED: communication active 13-4 x lighting LED 14 - Camera 5

2 Descrizione 2.2 Back view 8 7 6 5 1 2 3 4 1 - Loudspeaker volume adjustment 2 - Jumpers (see table in the Programming section). 3 - SCS/BUS connection 4 - Connection of the door lock and door lock release pushbutton 5 - Additional power supply 6 - Configurator socket 7 - MiniUSB connector for the connection to the PC 8 - Microphone volume adjustment 6

3 Installation 3.1 General rules for installation Vandal-resistant entrance panel Installer manual The camera must not be installed facing strong light sources, or in locations where the area being shot is strongly backlit. In order to resolve these problems, we recommend that the camera is installed at a height of 180 cm, instead of the usual 160 165 cm, with the lens pointing down. This will improve image quality. In low light situations, the colour rendition of the image displayed by the colour camera may decrease. This is to ensure that the person being displayed can be better recognised. To ensure optimum vision in low lit rooms, the installation of an additional light source is recommended. 160 165 cm 135 140 cm Typical installation heights 3.2 Technical features 1/4 sensor lens F: 2,1 mm; f: 1,0 mm Power supply 18 27 Vdc Absorption: 105 ma (stand-by) 340 ma (max in operation) Interlaced 2:1 400 lines resolution(horizontal centered) Night lighting by the white LEDs Automatic brightness adjustment Operating temperature (-25) (+70) C Angle of vision: horizontal 124 vertical 100 Protection index: IP54 Protection index against mechanical impact: IK07 7

3 Installazione 3.3 Dimensional data Flush mounted installation 180 58 50 128,2 35,2 330 259,6 Wall mounted installation 180 58 54 330 308026 8

3.4 Flush mounted installation Vandal-resistant entrance panel Installer manual 2 3 4 1 3.5 Wall mounted installation 1 2 3 308026 9

3 Installation 3.6 Phisical configuration P N T S Entrance panel number Call number (Not used) Door lock time delay Type of call signal J1 J2 J3 J1 - J2 Jumper connected to J1 (default) = control speech synthesis enabled; sound notification disabled Jumper connected to J2 = control speech synthesis disabled; sound notification enabled J3 Remove in case of additional power supply 10

2 1 BUS PL S+ S 3.7 Connections Vandal-resistant entrance panel Installer manual 2 1 BUS PL S+ S S+S- = 18 V - 4 A impulsive 250 ma holding current (30Ω max) BUS Relay door lock BUS PL S+ S A 346250 S- S+ C NC NO BUS PL S+ S A 346250 S- S+ C NC NO NO NC C 8A cosφ = 1 24 Vac 4A cosφ = 0.7 24 Vac 3A cosφ = 0.4 24 Vdc 24 Vac 3.8 Volume adjustment In case of high pitch noise (Larsen effect), first try reducing the power of the microphone using a screwdriver on the corresponding potentiometer, until an acceptable level is reached. If the problem continues, adjust the potentiometer of the loudspeaker to eliminate the problem. If the volume is too low, increase first the volume of the loudspeaker and then if necessary also the volume of the microphone, remembering that the best solution is a clear transmission, without disturbance, at the limit just below the occurring of the Larsen effect. NO NC C + 11

3 Installation 3.9 Completing the installation Before securing the entrance panel to the wall fit the protection caps in their housings, ensuring that they are positioned correctly When switched on for the first time, the entrance panel will ask the user to select the linguage; once this has been done, it will be possible to access the menus LANGUAGE English Français * EXIT 12

3.10 Installing the accessories VIGIK transponder reader Vandal-resistant entrance panel Installer manual 2 1 CCT75NM key switch 2 1 13

3.11 Camera lens and display glass replacement To protect from acts vandalism, for the most delicate parts of the device we have included item 308034. This item makes it possible to replace the camera lens and the display glass in one operation 1 2 3 4 art. 308034 5 6 14

4.1 Access to the configuration menu Vandal-resistant entrance panel 4 Configuration using the keypad Installer manual Welcome Press and hold down simultaneously keys for more than 10 seconds PASSWORD + > 10 s Enter the access code (default 12345) PASSWORD 1 2 3 4 5 CONFIGURATION Language Panel settings Address book If the correct code has been entered, direct access to the configuration menu will be granted CONFIGURATION Phonic module settings FW versions EXIT To exit the configuration menu, or to return to the previous menu, select EXIT and press 15

4.2 If the password is forgotten If the password has been forgotten it s possible to reset it in this way: OFF ON Shut down the power supply OFF + + ON Keeping pushed the keys and turn on again the power supply The display shows the current password PASSWORD 45678 Press bell key to continue Press to continue 4.3 Language CONFIGURATION Language Panel settings Address book Press LANGUAGE Castellano English * Français Select the desired language Confirm The set language will be marked by an asterisk 16

4.4 Panel settings CONFIGURATION Language Panel settings Address book PANEL SETTINGS Device settings Password Home page 4.4.1 Device settings DEVICE SETTINGS Brightness Contrast Keyboard light ON Vandal-resistant entrance panel Select the menu Confirm Installer manual The DEVICE SETTINGS submenu can be used to set the following functions: Brightness Display brightness adjustment Contrast Contrast adjustment Keyboard light Keyboard light setting: ON = keyboard always on (default setting) ECO = the keyboard light comes on when in use OFF = the keyboard light is always off 4.4.2 Password setup PASSWORD SETUP Password 12345 EXIT To change the access password: Press Enter the new password PASSWORD SETUP Password 67890 EXIT Confirm 17

4 Configuration using the keypad 4.4.3 Home page The home page can be used to enter a customised welcome message, or any other message; the message can use a maximum of three rows of text of 15 characters (Template); to switch from upper case to lower case and vice versa use the arrow keys. The length of time the message is displayed on the screen (5, 10, or 15 sec.) (Timeout). Entering the text HOME PAGE Template 1 line Timeout 5 Text > Press HOME PAGE TEXT Line 1 > Line 2 > EXIT Select the row where to enter the new text, or change the existing text and confirm Line 1 EXIT HOME PAGE TEXT Welcome Press to select the text field Line 1 EXIT HOME PAGE TEXT MY TEXT Enter the text using the alphanumeric keypad, in the same way as you would write an SMS message on your mobile phone Confirm MY TEXT The new message will appear continuously on the home page for the period set a Timeout 18

4.4.4 Acoustic signalling ACOUSTIC SIGNALLING Key sound Lock code change beep Voice msgs: volume ON ON Vandal-resistant entrance panel Installer manual The ACOUSTIC SIGNALLING submenu can be used to enable/disable the following functions: Key sound Lock code change beep Voice msgs: volume Audible signal emitted when the keys are pressed Audible signal emitted when the door lock code is being changed: ON = short BEEP if the code entered is correct long BEEP if the code is incorrect OFF = Audible signal disabled Volume adjustment for voice messages broadcasted by the device The other menu items represent voice messages relating to events (e.g. Call in progress, End of call, etc.). They may be enabled/disabled individually with the following procedure. ACOUSTIC SIGNALLING Voice msgs: volume Call in progress End of call ON ON Select an item from the menu Press ACOUSTIC SIGNALLING Voice msgs: volume Call in progress End of call OFF ON Set as required Confirm Voice messages are only active when jumper J1 is connected (see Physical configuration). 19

4 Configuration using the keypad 4.4.5 Restore default settings PANEL SETTINGS Home page Acuostic signalling Restore default settings Select the function RESTORE DEFAULT SETTINGS Confirm EXIT The request to confirm the restore appears Press Default parameter values restored The settings of the entrance panel revert to the factory settings. This function does not delete the data contained in the residents address book. 20

4.5 Address book Vandal-resistant entrance panel Installer manual This menu can be used to enter residents data, including call codes and door lock release codes, as well as for performing any other functions described in the following paragraphs. CONFIGURATION Panel settings Address book Phonic module settings 4.5.1 Building type ADDRESS BOOK Building type * Calling mode Sorting of the list Press BUILDING TYPE Multifamily Single family EXIT 4.5.2 Calling mode - List of names CALLING MODE List of names OFF Type of code > Function of bell button > For systems with several apartments use Multifamily mode (default). In Single Family mode, the call is activated directly by pressing,without the need for selecting the extension. Press This setting determines how the names of the residents are displayed; if enabled, the display will show the following message: Select the name with and press To search the desired name use the indicated key, or enter the surname using the alphanumeric keypad. 21

4 Configuration using the keypad 4.5.3 Calling mode - Type of code CALLING MODE List of names ON Type of code > Function of bell button > Enter the type of code to use when calling the residents CODE TYPE Apart address * Call code EXIT Apart address Call code SCS address of the handset Numerical code assigned to the resident 4.5.4 Calling mode - Function of bell button CALLING MODE List of names ON Type of code > Function of bell button > To call the concierge press the button The key can be enabled for direct call to the switchboard. In multifamily: enable/disable the bell button for calling the switchboard In single family: set the address which will be called by the bell button (i.e. the address of the internal units, usually set to 0) Display in Switchboard mode To call press the button Display in Single Family mode 4.5.5 Calling mode - Recall CALLING MODE Type of code > Function of bell button > Recall OFF When this function is enabled, the entrance panel will automatically repeat the call every 10 seconds for up to 4 times. 22

4.5.6 Sorting of the list ADDRESS BOOK Building type Calling mode Sorting of the list Vandal-resistant entrance panel The names can be sorted alphabetically by surname or by identification code number. Installer manual SORTING LIST By surname * By ID number EXIT The sorting order set is marked by an asterisk. 4.5.7 Contact setting ADDRESS BOOK Contact setting New contact Modify contact The call codes and the door lock release codes can be set with a length of 1 to 8 digits for the Call code and 4 to 9 digits for the Lock code. CONTACT SETTING Call code digits 4 Lock code digits 5 EXIT 4.5.8 Modifiy contact Call code digits Lock code digits Length of the codes for calling residents (default 4 digits) Length of the door lock release codes (default 9 digits) ADDRESS BOOK Contact setting New contact Modify contact This function gives the possibility of changing the contact selected Aaaa Aaaa Bbbb Bbbb Cccc Cccc Select the contact to change Confirm 23

4 Configuration using the keypad 4.5.9 New contact ADDRESS BOOK Contact setting New contact Modify contact This function can be used to enter new residents in the address book For each resident it will be possible to set the following data: ID number (use if the desired order of the list is different from the alphabetical order) Surname (Text 1*) Name (Text 2*) Public Apartment address Call code Lock code Identification number; the entrance panel assigns a progressive number to each resident. This function gives the possibility of changing this ID with a 4 digits number defined by the installer. Surname of resident Name of the resident YES = The name and the surname of the resident appear on the display during the selection for call NO = The name and the surname of the resident are hidden, the call is possible by entering the Call code. Enter the handset SCS address Numerical call code Door lock release numerical code (*) If Sorting of the list is set to By ID number. In installations including an access control central unit, when a badge is placed near the central unit the contact Surname, Name and Apart address are automatically added to the address book. 24

4.5.10 Delete contact ADDRESS BOOK New contact Modify contact Delete contact Vandal-resistant entrance panel This function gives the possibility of deleting the contact selected Installer manual Aaaa Aaaa Bbbb Bbbb Cccc Cccc Select the contact to change Press DELETE THIS CONTACT? Confirm Aaaa EXIT Aaaa The request to confirm the elimination of the contact appears press 4.5.11 Delete address book ADDRESS BOOK Delete contact Delete address book EXIT This function gives the possibility of deleting all the contacts of the entrance panel address book Press DELETE THE ADDRESS BOOK? Confirm The address book EXIT will be deleted 25

4 Configuration using the keypad 4.6 Phonic module settings The configurations of this menu are only possible if the phonic (speaker) module is not configured physically SCS SETTINGS P -Panel number 00 T -Lock time 1 S -Call tone 0 P - panel number T - Lock time S - Call tone Switchboard Riser (M) Entrance panel SCS address Door lock time delay Type of call signal SCS address of the switchboard Riser address the EP is part of (M address of interface 346851 of the riser; set to None if the EP is installed on the backbone) Note: do not confuse this configurator with the other M referred to the operating mode 4.7 FW versions This menu shows the versions of the firmware installed on the device. FW VERSIONS LCD Module : 01.02.28 Phonic Module : 02.02.24 QUIT 26

4.8 Access control settings Vandal-resistant entrance panel The configurations of this menu are only possible if the phonic (speaker) module is not configured physically Installer manual ACCESS CONTROL SETTINGS Central address A/B) 00 Reader address (C) 1 Operating mode (M) 0 Central address (A/B) Reader address (C) Operating mode (M) Local management Address of the access control central unit that manages the reader (keypad built in the entrance panel). Reader address (keypad built in the entrance panel) in the ACC system. Operating mode: M=0 - The address book, the calling code and the door lock codes are managed by the entrance panel and can be modified locally from the menu or from the configuration software. M=2 - The address book, the calling code and the door lock codes are managed by the access control system and must not be modified locally. Note: Do not confuse this configurator with the other M referred to the address of the riser column. Full: The settings and the address book can be almost fully modified, with the following exceptions: - If the address book is not empty, the call code digits and the lock code digits cannot be changed. - If M = 2, lock codes cannot be changed Limited: a) The following options can be only remotely changed by the access control central: - Password - Language - Number of call code digits - Number of lock code digits - Riser base address b) The following menu options are not allowed in the installer menu because the acccess control central takes care of the address boook: - New contact - Modify contact - Delete contact - Delete address book 27

5 Configuration using the software 5.1 TiMonoblockEntrancePanel configuration software The TiMonoblockEntrancePanel software supplied with the device gives the possibility of configuring the entrance panel for use with video door entry systems only; In this case it will be possible to manage also the residents address book using the software. In order to use the entrance panel in systems with access control, the configuration must be completed using the device menu, while the residents address book will be managed by access control. 5.2 Connection to the PC To connect the entrance panel to the PC use an USB-mini USB cable USB - miniusb 28

6.1 Calling residents Residents may be called in three different ways: Vandal-resistant entrance panel 6 Using the entrance panel Installer manual 6.1.1 Searching using the arrow keys Select the name with and press Press one of the arrow keys to access the address book Aaaa Aaaa Use the arrow keys to scroll through the names until the name of the desired resident appears; for fast scrolling press and hold the key Dddd Dddd Press to send the call 6.1.2 Through surname search Select the name with and press Press one of the arrow keys to access the address book Aaaa Aaaa Dd Dddd Dddd Use the keypad in the same way as a mobile phone keypad to enter the surname, or even just the initial, of the contact to call Press to send the call 29

6 Using the entrance panel 6.1.3 Using the numerical code Select the name with and press If the resident s call code is known, simply enter it on the keypad 1 2 Insert the code Enter the resident s code 1 2 3 4 and press Press to send the call 6.2 Call to the switchboard (only in multifamily configuration) To call the switchboard press the button To call the switchboard directly press this key The switchboard called is the one configured in Phonic module settings Switchboard Switchboard 30

Vandal-resistant entrance panel 6.3 Call the only resident (Only in single family configuration) Installer manual To call press the button To call the only resident press this key Calling 31

6 Using the entrance panel 6.4 Door lock release using a numerical code The procedure to follow for releasing the door lock associated to the entrance panel using the lock code changes depending on the length of the codes assigned to the residents, which can be up to the maximum length set. Select the name with and press Press the key * * * * * * Enter your own Lock code Door open If the length of the code is the same as the maximum length set the door lock is released If the code is shorter than the maximum length set * * * * Press the key Door open 32

6.5 Changing the lock code Vandal-resistant entrance panel Each resident can change their lock code at any time using the following procedure. This procedure is not valid if the entrance panel is part of an access control system, and the operating mode is M=2. Installer manual Select the name with and press Press this key for at least three seconds LOCK CODE CHANGE Enter present code ****** Enter the current lock code Press the key LOCK CODE CHANGE Enter new code ****** Enter the new lock code Press the key LOCK CODE CHANGE Enter new code ****** Re-enter the new lock code Repeat new code ****** LOCK CODE CHANGE Press the key Note: - if M = 0: every resident has a unique lock code - if M = 2: the lock codes are managed by the access control central, and several residents can share the lock code If the new code already exists, an error message will be displayed. 33

BTicino SpA Viale Borri, 231 21100 Varese - Italy www.bticino.com BTicino SpA reserves at any time the right to modify the contents of this booklet and to communicate, in any form and modality, the changes brought to the same.