Level switch NS 10/NS 25..-AM

Similar documents
Level and temperature switch Nivotemp NT-M, NT-MD

Level- and temperature sensor Nivotemp NT M-XP

Level- and temperature sensor Nivotemp NT 67-XP

Level and temperature switch Nivotemp NT-M, NT-MD

Level sensor Stainless steel version Model RLT-1000, for industrial applications

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

Level Transmitter. Table of dimensions see page 4. Total length B Installation length A SW55 Ø 55 Ø 75

Level- and temperature switch. Nivotemp NT M. Installation and Operation Instructions. Original instructions. Fluidcontrol BE /2019

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi

Absolute encoders - modular bus covers

Temperature Switches

Float switch For industrial applications Model RLS-1000

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

MPreC - Pressure Relief Device Order specification sheet

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm

Electronic pressure switch with display For sanitary applications Model PSA-31

Stand: ELECTRONIC Product News 2010

LS 5000 series Vibration Level Switch for liquids

Linear Position Transducer HLT 1000-R2

Digital electropneumatic positioner

Level sensor for monitoring the level of liquid media

Standardized valve series MI-01 Connection pattern according to ISO 5599/1, size 1, 5/2- and 5/3-way NG and 1700 Nl/min (1.636 and 1.

P30-2. Overview. Pressure Transmitter Datasheet. *High Quality* 3 Years Warranty. At a Glance. Function. Application

C-Flow Coriolis Mass Flow Meter

Electronic Level Switch ENS 3000

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

Hydrostatic filling level sensor HFB C4 / R / MD

Inline filter. Features: RE 51402/09.10 Replaces: Types 100 FLEN 0160 to 0630; 100 FLE 0045, 0055, 0120

Level switch for tank installation. NT 61-Z0-Atex. Installation and Operation Instructions. Original instructions. Fluidcontrol BE /2017

Rotary Position Technology Incremental Encoders

NIVOSWITCH VIBRATING FORK LEVEL SWITCHES

Process displays For current and voltage

Electronic pressure switch with display Model PSD-4

Rotary Position Technology Absolute Encoders, Singleturn

Electronic pressure switch with display For sanitary applications Model PSA-31

Pneumatic Control Unit for the integrated mounting on process valves

FOR LIQUIDS AND SOLIDS

Technical data. General specifications. Functional safety related parameters B 10d Electrical specifications Operating voltage U B

Speed switches Programmable, digital speed switch With incremental encoder POG 10

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

Rotary Position Technology Incremental Encoders

Digital electropneumatic positioner

Float Flow Meter. Flow measurement for translucent liquids and gases DN10 to DN65 mm. Technical data Orifice DN 10 to 65

More Precision. indusensor // Linear inductive displacement sensors

Technical Data Measuring principle Bellow Repeatability ± 0.5 % FS typ.

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.

Digital electropneumatic Positioner for the integrated mounting on process control valves

21D Allfluid pressure switch, electromechanically actuated

Encoder WDGA 58B CANopen

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

Speed switches Programmable, digital speed switch With incremental encoder HOG 10

Digital electropneumatic Positioner SideControl

Linear Position Transducer HLT 1000-R2

selection of special materials is available to handle almost any fluid.

Viscosity-Compensated Flow Meters and Switches

Thermal Mass Flowmeter Sensyflow FMT200-D

21023, 21025, 2/2 Direct solenoid actuated poppet valves

Digital electropneumatic Positioner for the integrated mounting on process control valves

with extraction and return pipe

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

60 Ghz - Radar filling level sensor RFM 2000 C4 / R / MD

Electronic pressure switch with display For sanitary applications Model PSA-31

Absolute Encoders Multiturn

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution

RK-5 ENVIRONMENTAL DATA CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED CONNECTION. Main features

Operating Instruction for Turbine-wheel Flow Meter. Model: DRB-...

RK CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER (ANALOG OUTPUT OR START/STOP)

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

PRESSURE RELIEF DEVICE ORDERING SPECIFICATIONS.

Rotary Measurement Technology Absolute Encoders, Singleturn

IK4A (with ONDA technology)

Encoders without bearings - incremental Magnetic sensing, through hollow shaft max. ø180 mm pulses or 128 sinewave cycles per turn

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Flexible temperature transmitter and sensor

97100 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

RE 50220/ Type ABZMS-40. Component series 1X Maximum operating pressure 1 bar 1/10

Flow. Flow. N/en

Flow VA 500/

5/2 and 5/3 Directional-control valves, Series TC 15, G 1/4

Digital electropneumatic Positioner for the integrated mounting on process control valves

Encoder WDGA 58A PROFINET-IO (cov)

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Absolute encoders - modular bus covers Solid shaft with clamping or synchro flange Optical single and multiturn encoders 13 bit ST / 16 bit MT

Online data sheet RE13-SAC RE1 NON-CONTACT SAFETY SWITCHES

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2

Encoder WDGA 58F PROFINET-IO (cov)

Capacitance level switches LS 210 LS 220

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

Float switch 298. Use. Variants. + Sturdy construction with very few moving parts. + Standard flange with different hole patterns

Pneumatic Control/Feedback

Digital electropneumatic positioner SideControl

Absolute encoders - bus interfaces Solid shaft with clamping or synchro flange Magnetic single- or multiturn encoders 14 bit ST / 18 bit MT

Pneumatic Control/Feedback

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline

Absolute encoders - bus interfaces Encoder kit Magnetic single- or multiturn encoders 14 bit ST / 18 bit MT

Transcription:

Level switch NS 10/NS 25..-AM Fluidcontrol Oil tanks in lubrication and oil supply systems are often under overpressure compared to the ambient atmosphere. All oil moistened parts of devices mounted externally on the tanks or housings for monitoring the liquid level must therefore be pressure-resistant. The NS 10 and NS 25 series are designed for 10 or 25 bar (145 or 363 psi) operating pressures. The separate display float can easily be viewed inside the upstream guide tube and the magnetic field ensures the touchless connection with the interior main float. The variable electric switching contacts and/ or the continuous position encoder are located on the scale plate, which also holds the sight glass. On the NS 10 it is standard connected to the tank via pipe sockets and fittings, on the NS 25 via DIN flange. Level switch NS for external installation Visual and electric liquid level monitoring Operating pressure up to 25 bar (363 psi) Lengths up to 5000 mm (196.9 in) Adjustable level contacts Optional 4-20 ma analogue output Display with scale Compact design Particularly buoyant floats Special versions available upon request DA200201 08/2017 page 1 / 6 Buhler Technologies LLC, 1030 West Hamlin Road, Rochester Hills, MI 48309 Phone: 248.652.1546 / 49 89-0, Fax: 248.652.1598 e-mail: sales@buhlertech.com Internet: www.buhlertech.com

Technical Data NS 10..-AM Basic Unit Max. operating pressure Max. operating temperature spec. min. fluid weight Material Float SK166 10 bar (145 psi) 100 C (212 F) 0.75 kg/dm³ (0.027 lb/in³) NBR Riser 1.4571 Flange Sight glass Galvanised steel PC Sealing cap 1.4571 Version 0-AM 15-AM 25-AM Connection Tube Flange Flange DIN 2656 flange DN15 DN25 ØD 20 (0.8") 95 (3.7") 115 (4.5") Øk 85 (3.3") Ød 14 (0.6") 14 (0.6") b 16 (0.6") 18 (0.7") ØA 45 (1.8") 68 (2.7") h 12 (0.5") 14 (0.6") Weight at L1=500 mm (19.7") Weight L1+100 mm (3.9") approx. 7.5 kg (16.5 lb) Other versions available upon request Options Transducer tube Measurement principle approx. 0.2 kg (0.4 lb) -K continuous level Reed contact Resolution 5 or 10 mm (0.2 or 0.4") Operating voltage (U B ) Output Load Ω max. Accessories : 22 51 000 22 52 000 22 71 999 10-30 VDC approx. 8.0 kg (17.6 lb) approx. 0.2 kg (0.4 lb) 4-20 ma (nominal voltage 24 VDC) (U B 7.5 V) / 0.02 A approx. 8.75 kg (19.3 lb) approx. 0.2 kg (0.4 lb) Description: Flange seal 45/22x2 mm (1.8/0.9x0.02") (DN15) Flange seal 68/27x2 mm (2.7/1.1x0.02") (DN25) Mounting bolts 8 x M12x65 Pressure Equipment Directive information: The level switches are designed, manufactured and tested to Pressure Equipment Directive 2014/68/EU according to AD-2000 code. The actual category of the level switch achieved is printed on the type plate. Depending on the category, comprehensive quality assurance is performed according to module H or H1. 34 (1.3") 96 (3.8") Ø40 (1.6") 37 (1.5") No contacts here 125 (4.9") Ød 100 (3.9") b h ØA ØD Øk ØD optional transducer tube with continuous output signal L = (L1+258) (10.2") L1 = max. 2700 (106.3") 190 (7.4") 2 Buhler Technologies LLC We reserve the right to amend specification. DA200201 08/2017

Model key NS 10 Model key designation Version 0-AM 15-AM 25-AM Ordering example with pipe socket DN 15 flange DN 25 flange NS 10/-XX-XX-SK166/-XX Length L1 = mm Float Optional -K5 -K10 Transducer tube continuous resolution 5 mm (0.2") continuous resolution 10 mm (0.4") You require: Order Level switch for external installation, max. operating pressure 10 bar (145 psi), with DN15 flange connection, adapter spacing L1 = 1500 mm (59.1"), with 2 changeover contacts NS 10/15-AM-SK166 / 1500 2 x item no. 28 89 999 contact MKS 1/W DA200201 08/2017 We reserve the right to amend specification. Buhler Technologies LLC 3

Technical Data NS 25..-AM Basic Unit Operating pressure Operating temperature spec. min. fluid weight Material Float 1.4571 Riser 1.4571 Flange Sight glass max. 25 bar (363 psi) max. 120 C (248 F) SK661 0.85 kg/dm³ (0.031 lb/in³) Galvanised steel PC Version 15-AM 25-AM Connection Flange Flange DIN 2656 flange DN15 DN25 ØD 95 (3.7") 115 (4.5") Øk 85 (3.3") Ød 14 (0.6") 14 (0.6") b 16 (0.6") 18 (0.7") ØA 45 (1.8") 68 (2.7") h 12 (0.5") 14 (0.6") S for float SK661 205 205 S for float SK662 390 390 SK662 0.70 kg/dm³ (0.025 lb/in³) Weight at L1=500 mm (19.7") approx. 9.5 kg (20.9 lb) approx. 10.5 kg (23.1 lb) Weight L1+100 mm (3.9") approx. 0.4 kg (0.9 lb) approx. 0.4 kg (0.9 lb) Other versions available upon request Options Transducer tube Measurement principle -K continuous level Reed contact Resolution 5 or 10 mm (0.2 or 0.4") Operating voltage (U B ) Output Load Ω max. Accessories : 22 51 000 22 52 000 22 71 999 10-30 VDC 4-20 ma (nominal voltage 24 VDC) (U B - 7.5 V) / 0.02 A Description: Flange seal 45/22x2 mm (1.8/0.9x0.02") (DN15) Flange seal 68/27x2 mm (2.7/1.1x0.02") (DN25) Mounting bolts 8 x M12x65 Pressure Equipment Directive information: The level switches are designed, manufactured and tested to Pressure Equipment Directive 2014/68/EU according to AD-2000 code. The actual category of the level switch achieved is printed on the type plate. Depending on the category, comprehensive quality assurance is performed according to module H or H1. Ød Ø115 (4.5") 125 (4.9") b optional transducer tube with continuous output signal 68 (2.7") L1 S h ØA Øk ØD L = L1+S+68 (2.7") 4 Buhler Technologies LLC We reserve the right to amend specification. DA200201 08/2017

Model key NS 25 Model key designation Version 15-AM 25-AM DN 15 flange DN 25 flange NS 25/-XX-XX-XX/-XX Length L1 = mm Float type -SK661 spec. min. fluid weight 0.85 kg/dm³ (0.031 lb/in³) -SK662 spec. min. fluid weight 0.70 kg/dm³ (0.025 lb/in³) Option K5 K10 Transducer tube - continuous level measurement continuous resolution 5 mm (0.2") continuous resolution 10 mm (0.4") Ordering example You require: Order Level switch for external installation, max. operating pressure 25 bar (363 psi), with DN25 flange connection, spec. weight fluid 0.89 kg/dm³, adapter spacing L1 = 1500 mm (59.1"), continuous level output, 10 mm (0.4") ( resolution and with 2 changeover contacts NS 25/25-AM-K10-SK661 / 1500 2 x item no. 28 89 999 contact MKS - 1/W DA200201 08/2017 We reserve the right to amend specification. Buhler Technologies LLC 5

Contacts for NS..-AM MKS-1/K (-60) NC contact/no contact 230 V AC/DC 50 VA M3 (DIN EN 175301-803) 3-pin + PE 28 88 999 Pin assignment (Contact position empty tank) Mounted left Mounted right MKS-2/K 2 x NC contact/no contact 230 V AC/DC 50 VA S6 (DIN EN 175291-804) 6-pin + PE 28 91 999 MKS-1/W (-60) Change-over contact 230 V AC/DC 50 VA M3 (DIN EN 175301-803) 3-pin + PE 28 89 999 MKS-1/W-L 24 V (-60) Change-over contact with LED 24 V DC 25 VA S6 (DIN EN 175291-804) 6-pin + PE 28 90 999 red LED red LED Other contacts available upon request For applications in high shock and vibration environments we recommend using the MKS-1/K and MKS-2K contacts. Versions ending in -60 are for switch type NS 3/20 AM and have a pipe clamp for mounting to the level switch tube. When installing a transducer tube with continuous output signal the contact can only be installed on the left side. Pin assignment for AM-K with S3 connector Level out MKS 1/K, MKS 1/W MKS 2/K MKS 1/W-L24V 43 (1.7") 79 (3.1") 81 (3.2") 43 (1.7") 43 (1.7") 81 (3.2") 6 Buhler Technologies LLC We reserve the right to amend specification. DA200201 08/2017