Contact expander modules

Similar documents
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Two-hand control unit

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Two-hand control unit

E-STOP relays, safety gate monitors

Safe monitoring relays

E-STOP relays, safety gate monitors

Safe timer relay/contact expansion modules

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relay, safety gate monitor

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Two-hand control unit

Safe timer relay/contact expansion modules

E-STOP relay, safety gate monitor

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

E-STOP relays, safety gate monitors

Safety relays PNOZsigma

Products. Base units PNOZmulti Base units PNOZmulti PNOZ m0p (ETH) PNOZ m1p (ETH) PNOZ m2p (ETH) PNOZ m3p (ETH) 2.

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

PNOZ s2. Safety relays. Operating Manual EN-07

20 inputs for connecting, for example:

Can be configured in the PNOZmulti Configurator Semiconductor outputs: or 4 safety outputs in accordance with EN 954-1, Cat. 3

PNOZ s9. Safety relays. Operating Manual EN-08

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

PNOZ s1. Safety relays. Operating Manual EN-07

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

E-STOP relays, safety gate monitors

E-STOP relay, safety gate monitor

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Safe monitoring relays

E-STOP relays, safety gate monitors

Speed Monitor. Up to PL e of EN ISO PNOZ s30. Unit features

E-STOP relays, safety gate monitors

Datasheet - SRB 402EM-24V

Faults on the system Proximity switch connection technology:

PNOZ X1. } Safety relays. Operating Manual EN-08

Electronic monitoring relays PMDsrange

Datasheet - SRB 301LC/B-24V

PNOZ X2.1. } Safety relays. Operating Manual EN-05

Datasheet SRB301ST 24V (V.2)

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

Datasheet - SLB 200-C04-1R

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

PNOZ m EF 8DI4DO. Configurable Control System PNOZmulti. Operating Manual EN 02

PNOZ ml1p. PNOZmulti Modular Safety System. Operating Manual No EN-05

Safety Technique. SAFEMASTER C Multifunction Safety Module BH 5910

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

Two-hand relay modules SRB 201ZH 44 Schmersal Industrial switching systems

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

Safety Technique. SAFEMASTER C Multifunctional Safety Timer UG 6960

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

PNOZ m EF PDP Link. Configurable Control System PNOZmulti. Operating Manual EN 02

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

PSEN 4.2a/b/p/M12. PSEN sensor technology. Operating Manual EN-02

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

MSR178DP. Description. Features. Specifications

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

Vital. Safety controller. Approvals: Control of: Features: Entire safety system based on the dynamic safety circuit.

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

PNOZ m EF Multi Link. } Configurable control systems PNOZmulti 2. Operating Manual EN-04

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

PHOENIX CONTACT Features

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC

Installation / Control Technique

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

PSR UC/ESAM4/3X1/1X2/B

Safety Technique. SAFEMASTER Light Curtain Controller With Selectable Operating Modes BH 5902/01MF2

PSR DC/ESP4/2X1/1X2

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

ISOMETER isoev425 with coupling device AGH420

BETRIEBSANLEITUNG TECHNICAL INSTRUCTION INTERFACE PSE2-SC-02 (24 V AC/DC) Version 1.4

Safety Technique. SAFEMASTER C Multifunctional Safety Timer UG 6961

XPSMC16Z safety controller XPS-MC - 24 V DC - 16 input - 30 LEDs signalling

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

Bul. 440R Guardmaster Safety Relays (DI, DIS, SI, CI, EM, and EMD) Selection Guide

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

Transcription:

Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of safety contacts 13-14, 23-24, 33-34 from all other circuits Connection options for expansion modules LED for: Input status, channel 1 Input status, channel 2 Switch status of the safety contacts Plug-in connection terminals (either spring-loaded terminals or screw terminals) Unit description Gertebeschreibung The unit meets the requirements of EN 60947-5-1, EN 60204-1 and VDE 0113-1. The contact expander module is used to increase the number of instantaneous safety contacts available on a base unit. The category that can be achieved in accordance with EN 954-1 and EN ISO 13849-1 depends on the category of the base unit. The contact expander module may not exceed this. Safety features Sicherheitseigenschaften Kontakterweiterungen allg_pnoz The unit meets the following safety requirements: The contact expansion module expands an existing circuit. As the output relays are monitored via the base unit's feedback loop, the safety functions on the existing circuit are transferred to the contact expansion module. The safety function remains effective in the case of a component failure. Earth fault in the feedback loop: Detected, depending on the base unit that is used. Earth fault in the input circuit: The output relays de-energise and the safety contacts open. Block diagram Blockschaltbild * 13 23 33 43 51 K1 Interface base unit K2 Interface expansion module 14 24 34 44 52 *Safe separation in accordance with EN 60947-1, 6 kv

Function description Funktionsbeschreibung with PNOZsigma s7.1: Dual-channel operation and supply voltage via PNOZsigma connector with PNOZsigma expander modules: Dual-channel operation and supply voltage via PNOZsigma connector Timing diagram ][Zeitdiagram_PNOZs_Kontakterw_in_out_aux-rfk POWER Input Output safe Feedback t1 t2 t1 t2 Key Power: Supply voltage Input: Input circuits Wiring Verdrahtung Please note: Information given in the Technical details must be followed. Outputs 13-14, 23-24, 33-34, 43-44 are safety contacts, output 51-52 is an auxiliary contact (e.g. for display). To prevent contact welding, a fuse should be connected before the output contacts (see technical details). Use copper wire that can withstand 60/75 C. Sufficient fuse protection must be provided on all output contacts with capacitive and inductive loads. Output safe: Safety contacts 13-14, 23-24, 33-34, 43-44 Feedback: Feedback loop 51-52 t 1 : Switch-on delay t 2 : Delay-on de-energisation -2

Preparing for operation Betriebsbereitschaft herstellen PNOZs Supply voltage/input circuit/feedback loop Supply voltage/input circuit/feedback loop AC DC Contact expansion module PNOZs expansion module Interface PNOZsigma PNOZs expansion module

Terminal configuration Klemenbelegung. Installation Montage PNOZsigma_7_2 Connect contact expansion module to PNOZsigma contact expansion modules Connect the contact expansion modules using the connector supplied. Control cabinet installation The safety relay should be installed in a control cabinet with a protection type of at least IP54. Use the notch on the rear of the unit to attach it to a DIN rail. Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing element (e.g. retaining bracket or an end angle). Push the unit upwards or downwards before lifting it from the DIN rail. ][Montage_PNOZsigma_Erweiterungsgert_Kaskade_DB Expansion options Please note the max. power consumption of the contact expansion modules (see Technical data PNOZ s7.1). : Base unit PNOZ s7.1 PNOZsigma base unit with terminator... 1 2 4 3-4

: Base unit PNOZ s7.1 PNOZsigma base unit module s7/s8/s9/s10/s11 PNOZ s7, s8, s9, s10, s11 as terminator... 1 2 4 3 PNOZ s7.1 with terminator with terminator... 1 2 3 PNOZ s7.1 with terminator PNOZ s7, s8, s9, s10, s11 as terminator module s7/s8/s9/s10/s11... 1 2 3 : Base unit PNOZ s7.1 PNOZ s7.1 PNOZsigma base unit... 1 2 3 4 5 6 with terminator

Dimensions Abmessungen *with spring-loaded terminals 120 (4.72") 98 (3.86") * 100 (3,94") 17,5 (0.69") -6

NOTICE ][Wichtig_PDB This data sheet is only intended for use during configuration. Please refer to the operating manual for installation and operation. Service life graph Lebensdauerkurve_Relais_Text vor Kurve The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. Lebensdauerkurve Lebensdauerkurve_Relais_Text nach Kurve_SIF Bsp Example Inductive load: 0,2 A Utilisation category: AC15 Contact service life: 2,000,000 cycles Provided the application requires fewer than 2,000,000 cycles, the PFH value (see technical details) can be used in the calculation. To increase the service life, sufficient spark suppression must be provided on all output contacts. With capacitive loads, any power surges that occur must be noted. With contactors, use freewheel diodes for spark suppression. Technical details PNOZsigma

Technical details Electrical data Power consumption at U B DC 2.0 W Number of output contacts Safety contacts (S) instantaneous: 4 Auxiliary contacts (N/C): 1 Utilisation category in accordance with EN 60947-4-1 Safety contacts: AC1 at 240 V I min : 0.01 A, I max : 6.0 A P max : 1500 VA Safety contacts: DC1 at 24 V I min : 0.01 A, I max : 6.0 A P max : 150 W Auxiliary contacts: AC1 at 240 V I min : 0.01 A, I max : 2.0 A P max : 500 VA Auxiliary contacts: DC1 at 24 V I min : 0.01 A, I max : 2.0 A P max : 50 W Utilisation category in accordance with EN 60947-5-1 Safety contacts: AC15 at 230 V I max : 5.0 A Safety contacts: DC13 at 24 V (6 cycles/min) I max : 5.0 A Auxiliary contacts: AC15 at 230 V I max : 2.0 A Auxiliary contacts: DC13 at 24 V (6 cycles/min) I max : 2.0 A Contact material AgCuNi + 0.2 µm Au External contact fuse protection (I K = 1 ka) to EN 60947-5-1 Blow-out fuse, quick Safety contacts: 10 A Auxiliary contacts: 4 A Blow-out fuse, slow Safety contacts: 6 A Auxiliary contacts: 2 A Circuit breaker 24 VAC/DC, characteristic B/C Safety contacts: 6 A Auxiliary contacts: 2 A Max. overall cable resistance R lmax input circuits, reset circuits single-channel at U B DC 30 Ohm Safety-related characteristic data PL in accordance with EN ISO 13849-1: 2006 PL e (Cat. 4) Category in accordance with EN 954-1 Cat. 4 SIL CL in accordance with EN IEC 62061 SIL CL 3 PFH in accordance with EN IEC 62061 2.31E-09 SIL in accordance with IEC 61511 SIL 3 PFD in accordance with IEC 61511 2.03E-06 T M [year] in accordance with EN ISO 13849-1: 2006 20 Times Switch-on delay with automatic reset after power on typ. 30 ms with automatic reset after power on max. 50 ms Delay-on de-energisation with E-STOP typ. 18 ms with E-STOP max. 30 ms with power failure typ. 18 ms with power failure max. 30 ms Environmental data EMC EN 60947-5-1, EN 61000-6-2, EN 61000-6-4 Vibration to EN 60068-2-6 Frequency 10.0-55.0 Hz Amplitude 0.35 mm Climatic suitability EN 60068-2-78-8

Environmental data Airgap creepage in accordance with EN 60947-1 Pollution degree 2 Overvoltage category III Rated insulation voltage 250 V Rated impulse withstand voltage 6.00 kv Ambient temperature -10-55 C Storage temperature -40-85 C Protection type Mounting (e.g. cabinet) IP54 Housing IP40 Terminals IP20 Mechanical data Housing material Housing PC Front PC Cross section of external conductors with screw terminals 1 core flexible 0.25-2.50 mm², 24-12 AWG No. 750177 2 core, same cross section, flexible: with crimp connectors, without insulating sleeve 0.25-1.00 mm², 24-16 AWG No. 750177 without crimp connectors or with TWIN crimp connectors 0.20-1.50 mm², 24-16 AWG No. 750177 Torque setting with screw terminals 0.50 Nm No. 750177 Cross section of external conductors with spring-loaded terminals: 0.20-2.50 mm², 24-12 AWG No. 751177 Flexible with/without crimp connectors Spring-loaded terminals: Terminal points per connection 2 No. 751177 Stripping length 9 mm No. 751177 Dimensions Height 100.0 mm No. 751177 98.0 mm No. 750177 Width 17.5 mm Depth 120.0 mm Weight 170 g Technische Daten_Satz No. No. stands for order number. Si-Kennzahlen_Zusatz_Relais_Lebensdauer_PDB It is essential to consider the relay's service life graphs. The relay outputs' safety-related characteristic data is only valid if the values in the service life graphs are met. The PFH value depends on the switching frequency and the load on the relay output. If the service life graphs are not accessible, the stated PFH value can be used irrespective of the switching frequency and the load, as the PFH value already considers the relay's B10d value as well as the failure rates of the other components. Si_Kennzahlen_Erläuterung_1 All the units used within a safety function must be considered when calculating the safety characteristic data. Si_Kennzahlen_Erläuterung_2 INFORMATION A safety function's SIL/PL values are not identical to the SIL/PL values of the units that are used and may be different. We recommend that you use the PAScal software tool to calculate the safety function's SIL/PL values. Technische Daten_Satz Normen The standards current on 2007-07 apply. ][Dauerstrom_DC

Conventional thermal current while loading several contacts Number of contacts I th per contact at U B DC 1 6.00 A 2 5.50 A 3 4.50 A 4 4.00 A Bestelldaten Order reference Type Features Terminals Order no. C 24 VDC With spring-loaded terminals 751 177 24 VDC With screw terminals 750 177-10