ATS l AU AUTOMATIC TRANSFER SWITCH

Similar documents
ATS l AU AUTOMATIC TRANSFER SWITCH

North Power 5H04 PRIME POWER:454 KVA KW STANDBY POWER: 504 KVA KW

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet

ATS CONTROLLER OPERATING MANUAL

HAT560NC SERIES (HAT560NC /HAT560NBC) ATS CONTROLLER USER MANUAL

Comprehensive Modular Genset Controller

Compact Genset Controller, CGC 400 Generator control and protection Engine monitoring and protection Generator and mains breaker control RS485 Modbus

DKM-407 DIN RAIL TYPE NETWORK ANALYZER

Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx

SENTRON ATC Automatic Transfer Control Device

DATA SHEET Compact Genset Controller, CGC 200

Neon pr. ph/ ORP measurement. Applications. Description

PRODUCT SPECIFICATION. PC Board Relays. Series.

Your technology partner Datakom, innovative products, affordable prices.

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

InteliLite MRS17 Click Here to Learn More

MULTICHANNEL DATA RECORDERS

AUTOMATIC TRANSFER SWITCH CONTROLLERS ATL SERIES

CertaDrive. LED indoor drivers. May, Design-in guide - Philips CertaDrive Indoor LED drivers

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Micro Contactor MA Series

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

HGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology

Product Sheet ECO. Types ECG, AMF Technical data. product sheet eco ecg-amf - technical data gb v1.0.docx

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

HF-Selectalume TL-D II

ATU800. Technical specification

100% electricity. Automatic transfer switch controllers ATL series

Expansion Module HZS 541-1S

Xitanium LED drivers spot and downlight fixed output LED driver 30W 400mA 69V 230V

Quick Start Guide TS A

GPM500 Generator Protection Module

DKM-405 NETWORK ANALYSER WITH TOTAL HARMONIC DISTORTION DISPLAY

Manual TU510A. Auto Transfer Controller HM1043ER1

DEEP SEA ELECTRONICS PLC

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

ESB ⅓ Hz 440Hz. Inrush Current Limiter, Inrush Current Protection For capacitive loads, 115Vac/230Vac 16A, 16 ⅓ Hz 440Hz, - 40 C...

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

MULTICHANNEL DATA RECORDERS

SafeC S. Features. Typical Applications. Technical Data. Principle. Safety Relay

is then retained absolutely without interruption.

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E

Installation and User Guide

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

Eaton DC Power Solutions

Distributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

Switched Mode Power Supply Operating manual PAP800

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

Xitanium. LED driver. Datasheet. Xitanium LED drivers - linear LV isolated. Xitanium 25W 0.5/0.6A 42V V

USER MANUAL 2012 V1.1

GSM HOME SECURITY SYSTEM

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED

Millenium II +: general characteristics

CurrentWatch Current Sensors. EGF Series Ground Fault Sensors. Ground Fault Sensors with Solid-State or Mechanical Relay Outputs.

Rapidus Power Factor Controller

Temperature controller Ducted systems

Xitanium Dim 100W 0.8A 1-10V 230V I175

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Safety Relay F 121 Emergency-Stop Relay, Safety Gate Monitor

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date:

Energy Management Solutions

Xitanium Outdoor LED Drivers Single Current

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Measuring and Monitoring Relays

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

02/11/2015

RS485 MODBUS Module 6RO

STEP-PS/1AC/24DC/1.75

Service/installation manual. DryRapid Controller. Code-No.: M5031GB. Edition: 05/2005

Industrial Power Supplies

LCI User Manual mantracourt.com

Xitanium. Xitanium 150W 0.7A 230V Y. LED Driver. Datasheet

MODEL: R2K-1 SEN TRONIC AG. R2K Series

SX90 Process Controller

LED driver 40W 1050mA 40V s 230V

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

MCX08M2 Programmable controller

DEEP SEA ELECTRONICS PLC

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Transcription:

ATS l AU AUTOMATIC TRANSFER SWITCH

MASCHINENBAU HALBERSTADT GROUP, building on its 60 years legacy in power generation, introduces a novel design of Automatic Changeover Switch ideally suited for quick, safe and reliable transfer of load between two energy supply sources automatically. INDEX POWER GENERATION 1 MAIN APPLICATION 2 GENERAL CHARACTERISTICS 3 ATS CONTOLLER 6 MANUAL OPERATION 10 DIMENSIONS 12 CATALOG NO. 16

www.mbhelectric.de POWER GENERATION EXPERTISE Several decades of experience and contribution to power generation technology have allowed Maschinenbau Halberstadt GmbH to conceptualize and tailor the ideal low voltage transfer switch that enables: Quick, safe and reliable transfer. Secure isolation. Minimum energy consumption. Minimizing downtime and service continuity. 1

MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH MAIN APPLICATIONS The transfer switch serves as an equipment to transfer load supply service between two sources. Utility to Generator For application with single utility feeder and a standby generator source. The transfer switch senses loss or abnormality in utility voltage then issues a remote start signal to the standby generator and transfers the load. Load is transferred back under normal utility conditions. LOAD Generator to Generator For application in a power system with multiple site generators. Load is transferred to secondary generation in the events of failure or scheduled maintenance. LOAD Utility to Utility For application with multiple utility feed. Transfer from one source to another is enabled in case of scheduled maintenance of source failure. LOAD Multiple Source System Multiple Source Systems may include multiple redundant utility feeds and/or multiple standby generators. Load is transferred to standby source in the event of utility (ies) failure in the case of multiple utility feeds. Load transfer to secondary generator is accomplished following the failure of both utility and standby generators. LOAD 2

www.mbhelectric.de GENERAL CHARACTERISTICS The ATS is intended for use in low voltage power networks in order to reduce and virtually eliminate outage periods of critical loads. The ATS ratings range from 100A to 3000A to cover the widest range of industrial, commercial and residential needs. MBH AU s unique design is optimized to ensure personnel safety, equipment protection and virtually eliminating outages thus combining safety, reliability and fast response. It is widely trusted to maintain service of critical and non-critical processes online at all time to enhance our client s manufacturing capabilities. Extended product lifetime through minimization of arcing time. On-Load Switching. Manual Bypass Capabilities. Dual switching strategies: 3 Stable switch positions (Main Source, Neutral, Emergency Source). Main Emergency or Main Neutral Emergency. Individual phase enclosure and arc chamber to improve breaking capacity. Enhanced main contact protection & breaking capacity. Easy to maintain. High transfer capabilities for inductive and motor loads. Safety All phases are fully insulated, each in its unique structure. The breaking chambers are fully enclosed to prevent contact with any live parts caused by insulation degradation following an arcing event. Safe conductive performance is ensured by applying adequate contact pressure at all times during operation. Compact Design The compact and unique design allows for switching between main source and emergency source through the use of one coil. The uniquely structured arc shute reduces the arc breaking time leading to longer contact lifetime. Stable breaking is ensured by the use of a breaking spring for tripping operations. Low loss and low energy consumption due to the application of instantaneous excitation mode. Both direct source transfer and transfer through neutral stable position are possible. Arc Chamber 3

MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH AU Technical Description AC 23B AC 23B AC 23B AC 23B 4

www.mbhelectric.de AC 23B AC 23B AC 23B AC 23B AC 23B 5

MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH AUC 173 DIN RAIL MOUNTED Features DIN Rail mounted. No DC supply required. Adjustable MCB and GCB delays. 10A/250VAC MCB and GCB outputs. 10A/28VDC/250VAC remote start output. Isolated mains and genset inputs. Inputs R-S-T: Mains phase voltages. G: Generator phase voltage. NEUT-MN: Mains neutral terminal. NEUT-GN: Generator neutral terminal. Outputs MCB-MAINS Contactor: Normally open relay output connecting the phase-r voltage to the terminal. (10A@250V-AC) Remote Start: Normally open engine start request relay output. (10A@28V-DC/250V-AC) GCB-Generator Contactor: Normally open relay output connecting the phase-g voltage to the terminal. (10A@250V-AC) Technical Specifications Alternator Voltage: 170-300 V-AC (Ph-N). Mains Voltages: 170-300 V-AC (Ph-N). MCB Relay Output: 10A @ 250V-AC. GCB Relay Output: 10A @ 250V-AC. Maximum humidity: 95% noncondensing. Dimensions: 70x115x66mm (WxHxD). Weight: 180g (approx.). Installation: DIN Rail mounted. IP Protection: IP20. Conformity (EU directives). 2006/95/EC (low voltage). 2004/108/EC (EMC). Norms of reference: Generator Contactor Delay: 1 to 40 sec. adjustable. Mains Return Delay: 1 to 40 sec. adjustable. Remote Start Relay Output: 10A @250V-AC/28V-DC. Operating temp.: -30 C (-22 F) to 70 C (158 F). Storage temp.: -30 C (-22 F) to 80 C (176 F). Case Material: High Temp. ABS/PC (UL94-V0). EN 61010 (safety requirements). EN 61326 (EMC requirements). 6

www.mbhelectric.de 7

MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH AUC 329 ATS CONTROLLER WITH MULTIPLE GENSET SUPPORT Features Automatic contactor control. Built in alarms and warnings. Statistical counters. 3 level password system. Field adjustable parameters. RS-232 serial port. Synchroscope & check synch. No break transfer & no break load test. Multiple genset system support. Electrical protections for genset. Load shedding, dummy load. Periodic maintenance request indicator. Built in daily / weekly / monthly exerciser. Event logging with time stamp and measurements. Battery backed-up real time clock. Weekly operation schedule programs. Firmware downloadable from serial port. Free MS-Windows Remote monitoring SW: Local and modem connection. Monitoring, download of parameters. Modem networking. GSM and PSTN modem support. GSM SMS message sending on fault. MODBUS communications. Graphic LCD display (128x64 pixels). User friendly graphic indicators. Triple language support. Customer logo display capability. Configurable digital inputs: 7. Configurable digital outputs: 2. Total digital outputs: 6. I/O expansion capability. Survives cranking dropouts. Sealed front panel. Plug-in connection system for easy replacement. Inputs The unit has 7 configutable digital inputs. Each input has following programmable parameters: Alarm type: shutdown / load-dump / warning / no alarm. Alarm polling: on engine running / always / on mains OK. Latching / non-latching operation. Contact type: NO / NC. Switching: BAT+ / BAT. 8

www.mbhelectric.de Outputs The unit provides 6 digital outputs and 2 of them have programmable functions, selectable from a list. Any function or alarm condition may be output as a relay output. Using two Relay Expansion Modules, the number of relays may be increased to 22, 16 of them being volt-free contacts. Alternator voltage: 0 to 300 V-AC (Ph-N). Alternator frequency: 0-100 Hz. Mains voltage: 0 to 300 V-AC (Ph-N). Mains frequency: 0-100 Hz. DC Supply Range: 9.0 to 30.0 V-DC. Typical Standby Current: 100 ma-dc. DC Outputs: 1A @ 28V. Weight: 300 g (approx). Conformity (EU directives). 2006/95/EC (low voltage). Norms: EN 61010 (safety requirements). Cranking dropouts: survives 0 V for 100ms. Maximum Operating Current: 200 ma-dc. (Relay outputs open) Generator/Mains Contactor Relay Outputs: 16 A / 250V. Current inputs: from CTs,.../5A. Max load 0.7VA per phase. Serial port: RS-232, 9600 bauds, no parity, 1 bit stop. Operating temperature: -20 C (-4 F) to 70 C (158 F). Storage temperature: -40 C (-40 F) to 80 C (176 F). Maximum humidity: 95% non-condensing. Dimensions: 165 x 125 x 48 mm (WxHxD). Panel Cut-out Dimensions: 151x111 mm minimum. Case Material: High Temperature ABS/PC (UL94-V0). IP Protection: IP65 from front panel, IP30 from the rear. 2004/108/EC (electro-magnetic compatibility). EN 61326 (EMC requirements). 9

MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH MANUAL OPERATION Manual operation is made feasible through the use of a handle connected to the side of the ATS and by making use of a metal pin to control source selection and tripping. Manual Bypass to Source A Source A: ON Manual Bypass to Source B Source B: ON Trip Source A: OFF Source B: OFF CAUTION: ATS Manual operation should be carried out under no load conditions and after careful inspection of live parts. 10

www.mbhelectric.de OPERATING CONDITIONS Ambient Conditions Avoid installation in humid areas, locations with risk of exposure to poisonous gas and high temperature places. Orientation The ATS is designed to be installed in a specific direction as highlighted in the figure. The ATS feature and performance may be subject to variation if the installation orientation changes. Ideally, the ATS should be installed so as the nameplate can be read properly facing the front and without any twist or bending of any ATS components. Control Circuit Connection Use low voltage control/power cable with sufficient length. In case of DC supply, make sure to take into consideration battery and charging characteristics. Main Circuit Connection Connect firmly by selecting appropriate wire sizes and solderless terminals. Avoid applying excessive stress to the main circuit terminal. Maintenance & Inspection Conduct maintenance and inspection at regular cycles in order to maintain the ATS performance. Recommended NOT Recommended 11

MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH AU DIMENSIONS AU 100A - AU 200A (Front) Type 3P 4P A 234 264 B 133 163 AU 400A (Front) Type 3P 4P A 287 338 B 192 243 12

www.mbhelectric.de AU 600A - AU 1000A (Front) AU600 AU800 AU1000 3P 4P 3P 4P 3P 4P A 340 400 400 480 400 480 B 224 284 284 364 284 364 C 220 220 239 239 239 239 D 30 30 31 31 31 31 E 40 40 40 40 50 50 F 20 20 40 40 30 30 G 60 60 80 80 80 80 H 5 5 8 8 10 10 I 36 36 42 42 42 42 J 60 60 54 54 56 56 K 248 248 267 267 267 267 L 58 58 80.5 80.5 79.5 79.5 M 53 53 63 63 63 63 13

MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH AU 1200A - AU 1600A (Front) AU1200 AU1600 3P 4P 3P 4P A 452.7 535.7 452.7 535.7 B 328 411 328 411 C 419.4 419.4 419.4 419.4 D 534.4 534.4 534.4 534.4 E 50 50 50 50 F 27 27 27 27 G 33 33 33 33 H 83 83 83 83 I 94.5 94.5 94.5 94.5 J 25 25 25 25 K 12 12 12 12 L 69 69 69 69 M 55 55 55 55 N 153.7 153.7 153.7 153.7 14

www.mbhelectric.de AU 2000A (Back) AU1200 3P 4P A 527.7 635.7 B 403 511 C - - D - - E 75 75 F 40 40 G 33 33 H 108 108 I 107 107 J - - K 15 15 L - - M - - N 152.2 152.2 15

MBH ELECTRIC AU AUTOMATIC TRANSFER SWITCH AU 3000A (Back) AU3000 3P 4P A 602.7 735.7 B 478 611 C 25 25 D 142.2 142.2 CATALOG NO. AUTOMATIC TRANSFER SWITCH Model AU Automatic Changeover Switch Switch Type S Standard AC Installation F Front Connection B Back Connection Controller c1 AUC 329 c2 AUC 173 Poles 3 3P 4 4P Supply voltage (shunt trip) 220 220V 110 110V Current Rating 0100 100A 1200 1200A 0200 200A 1600 1600A 0400 400A 2000 2000A 0800 800A 2500 2500A 1000 1000A 3000 3000A Enclosure ** Protection Index 16 ** Specify Protection Index

Authorized Distributor India Bliss Electricals Pvt.Ltd. SA42 A&B, 2nd Floor, Lake City Mall, Kapurbavdi Junction, Thane(W) - 400607 Landline - 0091-22 - 25368609 Cell - 0091 9819137944 e-mail - kane.shriram@blisselectricals.com www.blisselectricals.com MBH Middle East & Africa Halat, Lebanon T. +961 9 444 888 middleeast@mbhelectric.de MBH Gulf Baniyas Complex Nasser Square Al Rigga Area Deira, Dubai, UAE T. +971 4 239 5954, F. +971 4 239 5944 dubai@mbhelectric.de Maschinenbau Halberstadt GmbH (HQ) Rudolf Diesel-Strasse 50 Halberstadt 38820 Germany T. +49 1577 3394 113, F. +49 3941 24036 info@mbhelectric.de www.mbhelectric.de 2013 Maschinenbau Halberstadt Gmbh All rights reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use. Publication thereof does not convey nor imply any license under patent- or other industrial or intellectual property rights.