XR500/XR100 Command Processor Review. a) Zone expanders c) Output expanders b) All of these d) Single point detectors

Similar documents
Introduction. The Path Advantage

XT30/XT50 OVERVIEW. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training System Overview. XT30/XT50 Description

XT30/XT50 PROGRAMMING PART 1. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training Programming- Part 1. Accessing the Programmer

Property of Monitronics Inc

3/25/2015 Virtual Keypad Android App Help Guide - Rooms SCHEDULES

Customer Overview New Customer Setup Create a SmartShow: Virtual Demo Create a BOSCH System... 8

1HWZRU;1;( Table of Contents. General Description...2. Ordering Information...2. Feature Definitions...3. Programming the LED Keypads...

Ademco Vista-20SE/First Alert FA-162C Program Sheet

NX-148 LCD KEYPAD INSTALLATION MANUAL

U-FLASH Setup Guide U-FLASH.

Metasys Integrator Northern Application

VISTA 12a / 48a TECHNICAL TRAINING. The Best in Security plus Everyday Convenience & Control

I-NX8V2-IM Rev F Dec NetworX Series NX-8V2 Control Panel Installation and Setup

VISTA-128BP/VISTA-250BP Programming Form

DAS 250L CONTROL COMMUNICATOR INSTALLATION MANUAL

FPD-7024 Fire Alarm Control Panel Version 1.03

MG/SP Series (V4.9/V5.1) What s New

THE OPERATOR INTRODUCTION 2 ACCESSING YOUR SYSTEM 2 FUNCTIONS OF THE "OPERATOR" 3 PROGRAMMING/CHANGING ACCESS CODES 12 ACTIVATING EMERGENCY ALARMS 13

Series. NX-8-EUR Control Panel. Installation manual

Telephone and Reporting Setup in ElkRP

Control Panel. D9412GV4/D7412GV4/D7212GV4 v1.xx. Release Notes

Security System. Owner s Manual

801 Avenida Acaso, Camarillo, Ca (805) Fax: (805)

Modules Programming Guide. paradox.com

Installation Instructions

GV-AS/EV Controller. User s Manual

ACTpro Single Door IP Controller. Operating & Installation Instructions

Virtual Keypad App Help Last update: 2017/02/02

USER GUIDE. for ios Version 1. alula.net ALULA 1

791/793 Easy Entry Keypads

Installation Instructions

Delivered the Way Yo u Want

DSC PowerSeries Neo Integration

ACCESS CONTROL SOFTWARE V3.1 REFERENCE MANUAL

Created by: Alarm System Store Quick Start Guide. for Interlogix NetworX NX4, NX6 & NX8

Control Panel ICP-SOL2-P/ICP-SOL3-P. en Quick Reference Guide

Control Panel Solution 2000 / 3000

GETTING STARTED. Installing the System 2000 Hardware. Configuring Your System 2000 Hardware. Troubleshooting. Configuring Your System 2000 Network

INSTALLATION SHEET 791 and 793 Easy Entry Keypads

Operations & Installation Manual

4140XMPT2 PROGRAMMING FORM

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

Access control panel U-Prox IC E (Elevator control)

SILENCING AN ALARM. When the alarm bell or siren is sounding, enter your user code or present your keyfob to your keypad.

Developer s Guide. PC54O1 Serial Interface Module Version 1.0

SOFTWARE VERSION 3.10

Property of Monitronics Inc

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO D ISSUED NOVEMBER 2002 VERSION 2.

Content. Chapter 1 Features

epad 5.0 Mobile Keypad

ACTpro 1500 Single Door IP Controller

Model Number(s): D7000, D9000 Series Panels, D7000/9000V2 Panels

EC-11 Ethernet Converter

Access Control Unit User s Guide

USER GUIDE. for Android Version 1. alula.net ALULA 1

7-inch Digital Intercom Monitor User s Manual

PROGRAMMING HELP GUIDE

Property of Monitronics Inc

Configuring Cisco Access Policies

DS-K2600 Series Access Controller. Quick Setup Guide. Ness V1.0

RANGER 9000E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Colour Graphic Terminal User Manual. Rev 3.1

CUSTOMER INFORMATION

TECHNICAL OPERATION GUIDE

TM50 Touch Intuitive Touchscreen

*00 INSTALLER CODE Enter 4 digits, 0-9 [4140] *28 POWER UP IN PREVIOUS STATE [1=yes] 0=no; "1" for UL.

GV-AS Controller. Installation Guide

ATS1190 Smart Card Reader Programming Manual

ZDL-V200. Refer to Steps: 1 Thru. 4 Please Follow Wiring Steps Carefully.

NetworX Series NX-8V2 Control Panel Installation and Startup

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

Startup Guide. NetAXS-123. Version 5.2

6222 Two Door Module Technical Operations Manual

Property of Monitronics Inc

IDS X-Series User Manual E Issued June 2013

SECURITY MODULE CG3 User Manual

QUICK START GUIDE. 2.4 Inch Finger Vein Terminal Time Attendance & Access Control

FOCUS 200 PLUS A CCC #: _ / / _ / ( _ ) _ - 35(/,0,1$5< -8/< Security Services CUSTOMER CONTROL UNIT TELEPHONE NUMBER:

Flap Barrier User Manual

Dryer. M720 Programming and Operation Manual. July 15, 2015 Revision 1.51

Solution 16 plus. User Guide Security System

Avantis AXI WEB SERVER MODULE USER MANUAL

IS2000. Administrative Operator s Guide. AOG-101 (07/2005) Software Version 7.45

VTH16 Series User s Manual

AXS-100. User's Guide. Two-Door Proximity Access Control System (V2.06) DE6280U 1

GPRS Pager 3 INSTALATION AND USER MANUAL

Mobile Access, TimeTec Smart Flap Turnstile FTS 2100B & 2200B Installation Manual

Technical documentation

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): DSC POWER SERIES / IT-100

Integration Note. Manufacturer: OVERVIEW AND SUPPORTED FEATURES. Model Number(s): Power Series / 5401

Safecom Solution-16 Quick Reference Guide ISSUE 1.10

GV-AS200 Controller. Hardware Installation Guide

D1260/D1260B. Owner's Manual. Keypad

installation quick guide integrated access control & environmental monitoring

High Security and Access System EVO48 V2.1 EVO192 V2.1

Installation Guide. Thinline LCD Keypads 7560, 7563, 7570, 7573 Aqualite LCD Keypads Models 7560A, 7563A, 7570A, 7573A

R A D I O N I C S. D7212B Control/Communicator Program Entry Guide C 9/95

VISTA-50P VISTA-50PUL

WIRING DIAGRAMS. Installation and wiring of NVIROMON system NVIROMON MULIODCBPSU. Remote Environmental Monitoring and Control for IT equipment.

7760 LCD Glass Keypad

Transcription:

Name Answer Key Company Address City, State, Zip Instructor Date Your email User Name = Password = XR500/XR100 Command Processor Review 1. may be connected to the LX-Bus. a) Zone expanders c) Output expanders b) All of these d) Single point detectors 2 The panel's Yellow wire is the wire. a) Receive b) transmit c) auxiliary power d) smoke power 3 When a FIRE type zone is in ALARM, which account number is reported to central station? a) Area #1's account number c) Main Account number in Communication b) Area #0's account number d) No account number is sent 4 Select this communication type when you want the panel to send signals to the central monitoring station using a network connection. a) NET c) DD b) MPX d) CID 5 Zones 1 through 8 cannot detect conditions. a) Ground fault c) Shorted b) Open d) Normal 6 XR500 Series panel addresses are capable of handling four expansion zones when using DMP Security Command keypads or zone expander modules for a total of keypad bus expansion zones. a) 8 c) 16 b) 200 d) 64

7 Selecting the Adaptive option for a backup path to adapt to the check-in programming from this groups primary path if the primary path become unavailable. 8 The J1 Ethernet connector is not operational when the on-board RS-232 connection is enabled (XR500). 9 The DISPLAY AREA option in Device Setup allows 'area-grouping' and works in conjunction with Menu Display and Status List options. 10 The SCHEDULE CHANGE option allows the panel to send a report of all schedule changes. a) Output c) Opening and Closing b) Shift d) Lock and Unlock 11 The SWINGER BYPASS TRIPS option determines how many times a zone can trip in before the panel will automatically bypass the zone. a) 15minutes c) a Shift b) 30 minutes d) 60 minutes 12 The COMM FAIL OUTPUT will turn on when the panel has failed to communicate with the receiver after dial attempts. a) 3 b) 4 c) 7 d) 10 13 All programming changes will be lost if. a) The battery is not connected c) the STOP routine is not run b) The panel is not initialized d) programming is not done at keypad #1 14 When a device's DISPLAY AREA has areas 1 and 3, what happens when a user with Authority to disarm areas 1-32 disarms from the device? a) All areas are disarmed c) no areas are disarmed b) Only areas 1 and 3 are disarmed d) all disarm, but only 1 and 3 send reports 15 A 16-zone expander on LX Bus #1 is addressed 16. What would be the zone number for the FIFTH zone on this expander? a) 820 b) 520 c) 521 d) 821

16. When the keypad displays RESET PANEL, what must be done? a) J16 must be shorted c) panel must be powered down b) initialize programming d) keypad should be replaced 17. The maximum voltage drop between the panel and any device is. a) 12 VDC b) 2 VDC c) 2 VAC d) 5 VDC 18. The 3 rd zone connected to Keypad Bus address #3 is Zone Number. a) 3 b) 505 c) 33 d) 103 19. The 1 st zone connected to Keypad Bus address #8 is Zone Number. a) 11 b) 80 c) 81 d) 1 20. The LOCAL IP ADDRESS refers to the. a) the panel s IP address c) the receiver s IP address b) the network address d) none of these 21. The programming option provides supervision of the network communication path. a) SUB CODE b) CHECKIN c) FAIL TIME d) PASSPHRASE 22. There are 8 paths of communication 23. When manually configuring the panel to communicate over the network, you must know the Local IP, Remote IP and IP addresses. a) Server b) Trap Server c) Gateway d) icom 24. The CHECKIN MINS default time for NET is 200. 25. When DHCP is set to NO, the LOCAL IP ADDRESS is: a) static b) dynamic c) unchangeable d) temporary

Answer questions 26 35 using the information provided on page 5. 26. Which one of the areas is a Common Area? a) Area 1 b) Area 2 c) Area 3 d) Area 4 27. The door schedule for D2 is from: a) 9am to 5pm b) 8am to 4pm c) 24 hour d) None of the above 28. If the Access and Egress field are left blank, any valid code will be. a) granted b) denied 29. Each AREA to be used in the system must have. a) a name b) assigned zone c) access doors d) a schedule 30. The Warehouse Employees profile can only access the Warehouse (area 3) after the Warehouse (area 3) has been disarmed. 31. No profiles are allowed to arm the Break Room (area 4) because it is a common area. 32. What type of schedule is used to restrict access to certain individuals? a) Door Schedules b) Shift Schedules c) Area Schedules d) None of these 33. Anti-pass back has been enabled for Profile #11 and #12 because they have access to the vault which has access and egress requirements. 34. Profile #12, the Management Profile, can arm and disarm areas. a) 6, 7, 8 and 9 b) 1, 2, 3 and 5 c) all d) None of the above 35. Device 3 has an Access area. a) 1 b) 2 c) 3 d) 4

Information for questions 26 through 35 Area Area Name Auto Arm Auto Bad Zones Armed Late Output Common Area Information Disarm Output 1 LOBBY No No Bypass 0 0 No 2 OFFICE No No Bypass 0 0 No 3 WAREHOUSE No No Bypass 0 0 No 4 BREAK ROOM No No Bypass 0 0 Yes 5 VAULT No No Bypass 0 0 No DEVICE Name Access Egress SETUP Device 1 Keypad Device 2 Lobby Door 1 Device 3 Office Door 2 Device 4 Warehouse Door 3 Device 5 Vault Egress 5 Device 6 Vault Access 5 Device 7 Office / Whse Door 2 Door Schedule D2-8am-4pm

Area Schedule (Area schedules set to Yes ) Area 1- S1/ Open 8am-Close 5pm Area 2- S1/ Open 12:00am-Close 11:59pm Area 3- S1/ Open 12:00am-Close 11:59pm Area 4- S1/ Open 8am-Close 5pm PROFILES Profile # 11 ADMINISTRATOR Profile # 12 MANAGEMENT Profile # 13 CLEANING CREW Profile # 14 WAREHOUSE EMPLOYEES Arm/Disarm Areas 1 2 3 5 6 7 8 1 2 3 5 1 2 3 None Access Areas 1 2 3 5 6 7 8 1 2 3 5 1 2 3 3 Output Group 0 0 0 0 Arm / Disarm Yes Yes Yes No Alarm Silence Yes Yes Yes No Sensor Reset Yes Yes Yes No Door Access Yes Yes Yes Yes Armed Areas Yes Yes Yes No Outputs ON/OFF Yes No No No Zone Status Yes No No No Bypass Zones Yes No No No Zone Monitor Yes No No No System Status Yes No No No System Test Yes No No No Profiles Yes No No No User Codes Yes No No No Schedules Yes No No No Set Time Yes No No No Display Events Yes No No No Service Request Yes No No No Fire Drill Yes No No No Extend Schedules Yes No No No Temp Code No No No No Anti Passback Yes* Yes* No No Allow (ANY 1234) Anytime Shift 1 Shift 2 Shift 1 NOTE 1: Because profiles 11 and 12 have access to Area 5 (VAULT), we have enabled Anti-pass back for these profiles. NOTE 2: No profiles have authority to arm/disarm Area 4 because it is a COMMON AREA. LT-1012 (12/08) 2008 Digital Monitoring Products, Inc. *LT-1012*