Rigid Planters All Makes & Models

Similar documents
Ridged Planters All Makes & Models

Front-Fold Planters All Makes & Models

Miller Nitro 4000 Series

Note: Indented items indicate parts included in an assembly listed above

Note: Indented items indicate parts included in an assembly listed above

Note: Indented items indicate parts included in an assembly listed above

Direct Injection Module

Ag Leader Technology. DirectCommand Installation Miller Nitro 5000 & 6000 ISO Kit

Table of Contents ISO Liquid Implement Kits...1

DirectCommand Installation DirectCommand Complete Wiring Harness

Ag Leader Technology. DirectCommand Installation Rogator 900/1100/1300 Sprayers

InSight Single Implement

Ag Leader Technology. DirectCommand Installation Hardi 20-pin Interface Kit (Sprayer Chassis Mount)

Tile Plow Installation O Connell

Part Name/Description Part Number Quantity

Local CAN Troubleshooting

Tile Plow Installation Gold Digger

Part Name/Description Part Number Quantity

DirectCommand Installation 5 Channel Spreader Control Module Technology

Raven Adapter Harness

DirectCommand Installation RoGator Model Year Ag Leader Technology

Note: These installation instructions are only for the 4430/4440 Sprayer. For other SPX models please refer to P/N , &

Ag Leader Technology Insight. Direct Command Installation Spra-Coupe 7000 Series

DirectCommand Installation CASE IH SPX Ag Leader Technology. PN: Rev. E January 2014 Page 1 of 19

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

DirectCommand Installation RoGator 864/874/1064/1074 (MY 2006 & Earlier) Ag Leader Technology

RAM Rail Mount Kit RAM 201U 5 Arm RAM 2461U Monitor Mount RAM 235U Base, Double U-Bolt

ISOBUS Working Set. One or more ISOBUS modules that control an implement s functionality. Main module is called the Working Set Master (WSM).

Cab Box Kit Dome Plug Cab Box Cab Box Lid

DirectCommand Installation Case/Flexi-Coil/New Holland Air Cart Kit (Variable Rate Electro Hydraulic Systems) Ag Leader Technology

ISOBUS Quick Reference Installation Guide. Liquid Fertilizer Anhydrous Ammonia Sprayer Spreader Slurry

Ag Leader Technology. DirectCommand Installation GVM Cab Kit (MY 2007 and Up) Important Notices

Installation and Configuration Manual SeedStar/Graham Interface Board

SMI-100 Stack Monitoring Interface Installation & Operation Manual

DirectCommand Installation Hardi Spray Box II 39-pin Kit. Ag Leader Technology. PN: Rev. E January 2014 Page 1 of 16

Trouble Shooting Leveling Control Box Electric Jacks. Touch Pad LED Probable Cause Solution

Part Name/Description Part Number Quantity

OPERATOR S MANUAL. Safety Notices... 1 Disclaimer... 1

Table of Contents Kinze PMM...1

High Power over Ethernet Midspans PD Port Model PD Port Model

RedEdge-M TM / DJI Matrice 100 INTEGRATION GUIDE

Ag Leader Technology. DirectCommand Installation RoGator Model Years

Keysight Add Source and Receiver Attenuators Upgrade Kit

PN: A. ParaDyme System Auxiliary Harness Installation Guide

Replacing the Billboard Router

RECOMMENDED TOOLS PERSONAL & VEHICLE PROTECTION MASKING TAPE

Case AFS PRO 300, 600, 700 & INTELLIVIEW II, III, IV (Case & NH ISObus Ready) Display Kit Installation Manual 54VT-PRO-PT01

Hi-Tech Transport Electronics, Inc. DUAL LEVELING VALVE PROCESSOR INSTALLATION MANUAL. For the 4600 Scale System For the 5600 Scale System

INSTALLATION INSTRUCTIONS

Be sure to always check the camera is properly functioning, is properly positioned and securely mounted.

Cobalt - Basic Setup Setting up Grower, Farm, Field

RedEdge/3DR Solo INTEGRATION GUIDE

Activations. Set date and time prior to entering Activation codes to ensure the Activations will be acknowledged. Data Transfer

QuickTouch (QT4) Owner s Manual

OPERATOR S GUIDE. Document revision: 1.0 Last revised: January 29, 2018

LINEAR ACTUATOR CONTROL Use with NEW LEADER 7 manual

INSTALLATION INSTRUCTIONS

ITB THROTTLE WITH INTEGRATED STEPPER MOTOR INSTALLATION INSTRUCTION

Field Update Guide. for Raven Viper Pro

OPERATOR S MANUAL. Safety Notices... 1

TLS-3XX Series Consoles

Installation Instructions

*740130* 2800, 9500 Series. Cable Companion Motor Power. Cable AC Power. Cable Retrofit Acessories

SeedStar 4 Planter Quick Reference Guide

* C29* 68P81084C29-0 RETROFIT INSTRUCTIONS FOR MCS 2000 MOBILE RADIOS. Conversion From Dash/Local Mounting To Remote Mounting

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

RL-PCM3-TF. Rear-view camera-input and video-in-motion compatible with Porsche vehicles with PCM 3 and PCM 3.1 navigation systems

CU-8R Installation Instructions

Sidewinder Pumps Inc. AC Timer/Controller

PN Rev A

BK MIKRO. Air Barrier Adapter. Assembly Instructions Issue 1.00 dated

Safety Notices Tramline Setup Setup Input Type Input State (Hi/Lo) Assigning Sensors Auxiliary Power...

Quick Reference Guide for Daily use of Yield-Pro Planter

AutoScan to MultiScan Replacement Kit

COOPER POWER SERIES. RS-485 digital communications accessory board installation and operation instructions. Voltage Regulators MN225074EN

we can help you get there Wherever your Precision Agriculture is taking you... Service & Products for Precision Agriculture

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Power Rack 58. EXT-PS5-8R User Manual.

INSTALLATION INSTRUCTIONS

Overview of the Cisco VG224 Voice Gateway

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

Carbon Monoxide Sensor - ModBus

INSTALLATION INSTRUCTIONS

Be sure to always check the camera is properly functioning, is properly positioned and securely mounted.

APPLICATION SPECIFICATION. 1 of 22 B Millipacs HM 5 and 8 Row Right Angle Signal Receptacles Millipacs HM Right Angle Headers

PD-6506, PD & PD-6524

Assembly instructions. Joystick, OTTO and Danfoss. The noble art of digging. Version 1.0

PS/IO Circuit Board Retrofit

VM VM

Manual for PSDC_OPT_EIGHT_01: Optics Power Supply

EMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina

SERVICE PARTS MANUAL

OilCop Component Wiring Installation Manual

ECU REQUIREMENTS OUTLINE. Table of Contents HYDRAFORCE ELECTRONICS

Advanced Distribution Cable Junction Box For Spectra RMS Molded-Case Circuit Breakers with Advanced Feature microentelliguard TM Trip Units

INSTALLATION INSTRUCTIONS

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

RedEdge-M TM / DJI Inspire 1 Quick Mount INTEGRATION GUIDE

Control. Part B, Section 2. This section covers the following unit configurations. 3400V 3500V Voltage 1, 2, 3 Pump Piston (D, E, F, G)

SCION xb AUDIO Preparation. Part Number: PT BU or PT (Base Display Radio)

Transcription:

Rigid Planters All Makes & Models SureDrive TM Master Kit PN: 2006445-ENG REV. A

Introduction Important Information This guide provides the basic information needed to install the Ag Leader SureDrive system on a planter. It is intended to be used by Ag Leader dealers who are trained and knowledgeable about the installation of such systems. It is important to read this guide prior to beginning the installation. This guide contains warnings of potential hazards, and a collection of best practices that will help your installation go smoothly, safely and be successful. Trademark All brands and product names, unless otherwise stated, are registered trademarks of Ag Leader Technology. Technical Support Contact your Ag Leader Dealer or Ag Leader Technology for technical support. Telephone: (515) 735 7000 Email: support@agleader.com Legal Disclaimer Read and follow all instructions in this manual carefully before installing or operating the SureDrive system. Take careful note of safety information in this manual and additional safety messages provided throughout this and any other supplemental manuals provided. Ag Leader Technology disclaims any liability for damage or injury that results from failure to follow instructions, cautions and warnings communicated in this guide. 2

SureDrive Master Kit Installation Row Unit Components Required Items: Part Number QTY * Description 4004758 1 SUREDRIVE GEAR MOTOR Row Unit Specific 1 SUREDRIVE INSTALLATION KIT 4004426 ROW CONTROL MODULE (RCM) Row Unit Specific 1 RCM INSTALLATION KIT 4004085 or 4005014 1 1 ROW ACCESSORY CABLE (DF, VAC, SEED SENSOR, AUX ON/OFF) ROW ACCESSORY CABLE (SEED SENSOR, AUX ON/OFF) Row Unit Specific 1 IMPLEMENT SWITCH KIT (1-2 per planter) 4101335 1 PRESSURE SENSOR KIT FOR SEED METER (1-3 per planter) * QUANTITIES LISTED ARE PER ROW UNIT Installation Procedure: NOTE: Ag Leader advises fully equipping a single row unit before proceeding with all row units to insure compatibility in particular with non-ag Leader aftermarket parts that may be installed. 1. SureDrive Gear Motor (each row) Instructions provided in SureDrive installation kit. 2. RCM (Row Control Module) (each row) Instructions provided in RCM installation kit. 3. Implement Switch (at least one row, two rows recommended) Instructions provided in Implement Switch kit 4. Seed Delivery Pressure Sensor (for vacuum or air pressure meters) Instructions provided in Seed Meter Pressure Sensor kit. 3

Planter Frame & Tractor Components Required Items: Part Number QTY * Description 4101396 1 GENERATOR KIT 4101337 1 PCM KIT 4101370 1 PRESSURE SENSOR KIT FOR BULK FILL SEED DELIVERY 4002911 2 IMPLEMENT SWITCH MODULE 4002658 2 IMPLEMENT SWITCH CABLE See Table 1 N/A POWER DISTRIBUTION CABLES (See Table 1 on page 7 for additional clarification.) 4004876-2 2 LOCAL CANBUS EXTENSION 2 FT (FOR FLEX JOINTS IN TOOLBAR) 4004876-9 2 LOCAL CANBUS EXTENSION 9 FT (FOR FRAME FOLDING) 4004110-XX 1 IMPLEMENT HARNESS 2003131-XXX OR 4004076 1 1 HYDRAULIC HOSE KIT (TO TRACTOR) 25-65 FT HYDRAULIC HOSE KIT (TO TRACTOR) 12 FT 4101313 1 ISOBUS RETROFIT KIT 4002584-XX 1 ISOBUS RETROFIT BATTERY CABLE 4100879 1 SWITCH CONSOLE KIT * QUANTITIES LISTED ARE PER PLANTER ** QUANTITIES VARY BASED ON PLANTER CONFIGURATION AND PREFERENCE Installation Procedure: 5. Generator Instructions provided in Generator kit. 6. PCM (Planter Control Module). Instructions provided in PCM kit. 7. Seed Delivery Pressure Sensor (for bulk-fill planters) Instructions provided in Bulk-Fill Pressure Sensor kit. 4

Installation Procedure: 8. Install an implement switch module on toolbar in front of each row unit that is equipped with an implement switch. NOTE: Module can be secured loosely for now until local CAN Bus is routed and ideal location is determined. 9. Connect CAN implement switch cable to implement switch module that was mounted on toolbar in previous step. 10. Connect integral cable of implement switch to mating connector of CAN implement switch cable. A 42 in. extension cable is provided if required. NOTE: Local CAN connectors of implement switch cable will be connected when local CAN Bus is installed in a following step. Cables NOTE: The following steps detail how to properly install the Local CANBUS and power distribution cables. Refer to the line art drawing and table on the following two pages to aid in this process. NOTE: The line art on the following page illustrates what the electrical components of a narrow front-folding planter should look like. 12 rows are shown, but the same concept applies when there are more (or fewer) rows units and 6 rows across the back instead of 4. 5

Figure 1: Cable Routing Diagram 6

Table 1: Power Distribution Cables 6-Row 6/11 (30/15) 6-Row Power Distribution Cable (P/N: 4004976) 1 6 AWG Power Extension Cable - 10 ft (P/N: 4005001-10) (CENTER 4 ROW SECTION) 1 2 6-Row Power Distribution Cable (Narrow Row / Interplant) (P/N: 4005027) 2 11. Connect power extension cables to generator. Shortest extension is for center section connectors. Longer extensions are for outer wing connectors. See Table 1 on page 7 for additional clarification. NOTE: Power connectors on generator do not technically need to correspond to certain planter sections, but doing so is recommended for logical reasons. 12. Connect power distribution cables to extension cables installed in previous step. See Table 1 on page 7 for additional clarification. NOTE: Distribution cable shown is for 6 rows. Cables may have 4 or 8 drops, depending on planter configuration. 7

NOTE: The following 3 steps involve connecting the local CANBUS to the PCM. 13. Connect terminating plug to mating connector of RCM CAN stub at left-most row unit. It is important to use the correct terminator so the display will know that the left-most row unit is row #1. See Figure 1 on page 6 for additional clarification. 14. Connect terminating receptacle to mating connector of RCM CAN stub at right-most row unit. Connect each row unit RCM CAN stub to its adjacent row units so all row units are connected across planter. Connect PCM to local CANBUS at middle of planter using 9 ft CAN extensions. 2 ft CAN extensions are provided to go between row units where toolbar flex joints are present. 9 ft CAN extensions are provided to go around toolbar fold joints. 15. Install implement harness on planter frame near PCM and connect to PCM as follows: a. Power 1 connector of implement cable mates with ground receptacle of PCM I/O cable. b. ISOBUS plug of implement cable mates with receptacle of PCM ISOBUS breakout cable. 16. Install terminator (PCM kit) on remaining ISOBUS connector of PCM ISOBUS breakout cable. 17. Route opposite end of implement cable to tractor. Implement cable extensions are available if required. 8

18. Connect implement cable to IBBC connector of ISOBUS Power/Control assembly at rear of tractor. If an ISOBUS retrofit kit has not been installed, that must be done before this final step can be completed. Detailed installation instructions are provided in ISOBUS retrofit kit. See Figure 1: Cable Routing Diagram for additional clarification. Post-Installation Checklist All cable ends and terminations are connected. All cables are secured with cable ties. Verify planter can fold and unfold without cable damage. Verify CAN terminators are on correct ends of planter. 9