Title Power Supply Units for Signalling Equipment - DC (Regulated & Filtered) Units. Reference Number SPS 30 - (RIC Standard: SC SP)

Similar documents
Title Substations - Base Safety & Operating Standards. Reference Number POP 07 - (RIC Standard: EP SP)

Title System Substation Commissioning Tests. Reference Number PCP 07 - (RIC Standard: EP SP)

Status Date Prepared Reviewed Endorsed Approved

AC Immune DC Track Circuits Set-Up, Test and Certification

DC Track Circuits Set-Up, Test and Certification

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

LINEAR LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

COMPACT LED CONVERTERS 48 V

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , , , , , ,

AIR COOLED MODULAR RECTIFIER

LINEAR LED DRIVERS. ComfortLine Industry Selectable Current (LEDset) ComfortLine INDUSTRY SELECTABLE CURRENT (LEDset) ,

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH)

COMPACT LED DRIVERS. ComfortLine Residential. ComfortLine RESIDENTIAL , , ,

CUS150M1 Instruction Manual

CC COMPACT DIP SWITCH

LINEAR LED DRIVERS. ComfortLine NFC. ComfortLine NFC , , ,

Specification Voltage Limiting Device

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

Hybrid AC Driver [GCNC-1110]

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

Understanding SCCR. THE BEST ELECTRICAL CONTROLS BUSINESS ON THE PLANET! Unmatched Service Superior Product Quality Advantage Pricing

SPECIAL SPECIFICATION 6146 Fiber Optic RS-232 Data Modem

Transient Voltage Suppressor, Unidirectional

Voltage Current Front-mounting bracket

Safe monitoring relays

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

Enclosed Power Supplies

LINEAR LED DRIVERS. PrimeLine DALI dimmable. PrimeLine DALI DIMMABLE , , , , ,

S82S (3/7.5-W Models)

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

Ultra Motion Power Supply Unit User Manual

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

KUANTECH (SHEN ZHEN) COMPANY LIMITED KSAFD W1UK

PRODUCT. Battery Charger

COMPACT LED DRIVERS. EasyLine Selectable Current (Output Terminal) EasyLine SELECTABLE CURRENT (OUTPUT TERMINAL) , , ,

Table of Contents. 1 General 1.1 Scope

ENGINEERING SPECIFICATION SHEET SPEC. Revision History

RT4F-48V/50A-WAC RECTIFIER

Power Electronics. Semiconductor relay / - contactor

MESP TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V DC TRACTION SYSTEM

Model HM-535 Power Supply Installation and Service Instructions

The power factor of the typical switching power supply is between 0.4 and 0.6.

LL1x150-CR-DA. 150 W Dimmable DALI-2 LED driver. 150 W V 0 / Hz. Functional Description. Mains Characteristics

TM241C40R controller M IO relay

ELV12 Series. Instruction Manual

Original operating instructions Safety relay with relay outputs G1501S / / 2016

TM241C24R. Main. Discrete output type. Discrete output number. 14 (remote I/O architecture) 50 µs turn-on operation with I0...I13 terminal(s) input

Withstands max. 320 VAC (max. 1 hour) *) Low frequency, LED load: Cree XP-G L LEDs. 350 ma 600 ma Fixed output 850 ma P Rated

LC35SE-CC LOOP

LC51SE-CC LOOP

Electrical Demand Specification (Reference SOP: )

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

HF81 X Capacitor Bleeder

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

INTRINSICALLY SAFE Ex ia PSU TYPE AC36W

RTU500 series Data Sheet Power Supply CP-E 24/2.5

TM241CE40R controller M IO relay Ethernet

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

L05065 LED Driver 150W, 24-60Vdc, mA L1M1MLT400S-150E

PRODUCT SPECIFICATION

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

Overview Included in the Box: Pinout Installation Power Supply Stepping Motors DIP Switch (JP1) Location...

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Installation instructions Inclination sensor EC2019 EC / / 2013

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

LED Driver Linear / area fixed output

Surge Protective Devices. STV25K Series. Instruction Manual

PHASETRONICS. SCR Power Control Specialists. EP1 Series Power Control Single Phase SCR Amps OPERATION & SERVICE MANUAL

TM3TI4 module TM3-4 inputs temperature

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Pressure switch RE B/ Type HEDE10.../1/ Operating instructions

Bulletin 817 Thermistor Protection Relay

ENGINEERING SPECIFICATION SHEET. Table of Contents 1 SCOPE ELECTRICAL SPECIFICATION...5

Common to all H3CR. Basic Setting. Setting of Selectors. Selection of Operating Mode. Selection of Time Unit and Time Range. Common to all H3CR 1

TM3AI4 module TM3-4 analog inputs

LED Driver Linear / area fixed output

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

TM3TM3 module TM3-2 temperature inputs and 1 analog output

PowerFlex 400 AC Drive Guide Specification

1. Micro Drive Load sharing application note

TM241C24T controller M IO transistor PNP

Battery Chmgers. Farnell POWER

RT4F-120V/20A-WAC RECTIFIER

Safe monitoring relays

Install Motor Controller User Manual

POWERSOLVE ELECTRONICS LTD PSL400-XX series Conduction Cooled Power Supply Engineering Specification

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

L LED Driver 40W, 60Vdc, 1050mA, Dimmable L1M1MLT105S-40E L ND LED Driver 40W, 60Vdc, 1050mA L1MLT105S-40E

RT4F-110V/25A RECTIFIER

PERFORMANCE SPECIFICATION

Instruction leaflet for the VPAK DC TO HVDC CONVERTER (1kV to 10kV)

Installation Instructions H Series

E-STOP relay, safety gate monitor

L05055 LED Driver 60W, Vdc, mA L05059 LED Driver 60W, Vdc, mA L1M S-60E L1M S-60E

SE-135 MANUAL GROUND-FAULT GROUND-CHECK MONITOR

PC-250B Solid State Vital Biased Code Following Track Relay

User's Guide. MiniTec TM Series Model MN25 MultiMeter

ABL1REM24062 regulated SMPS - single phase V input - 24 V output W

ABL1REM Main. Rated power in W. Power supply output current V. <= 100 Aat 230 V AC. 2.5 Aat 240 V

Transcription:

Discipline Engineering Standard - NSW Category Signalling Title Power Supply Units for Signalling Equipment - DC (Regulated & Filtered) Units Reference Number SPS 30 - (RIC Standard: SC 09 10 07 00 SP) Document Control Status Date Prepared Reviewed Endorsed Approved May 05 Standards and Systems Refer to Reference Number Standards Engineer H Olsen GM Infrastructure Strategy & Performance M Owens Safety Committee Refer to minutes of meeting 12/08/04

Disclaimer Australian Rail Track Corporation has used its best endeavors to ensure that the content, layout and text of this document is accurate, complete and suitable for its stated purpose. It makes no warranties, express or implied, that compliance with the contents of this document shall be sufficient to ensure safe systems of work or operation. Australian Rail Track Corporation will not be liable to pay compensation in respect of the content or subsequent use of this document for any other purpose than its stated purpose or for any purpose other than that for which it was prepared except where it can be shown to have acted in bad faith or there has been willful default. Document Approval The technical content of this document has been approved by the relevant ARTC engineering authority and has also been endorsed by the ARTC Safety Committee. Document Supply and Control The Primary Version of this document is the electronic version that is available and accessible on the Australian Rail Track Corporation Internet and Intranet website. It is the document user s sole responsibility to ensure that copies are checked for curency against the Primary Version prior to its use. Copyright The information in this document is Copyright protected. Apart from the reproduction without alteration of this document for personal use, non-profit purposes or for any fair dealing as permitted under the Copyright Act 1968, no part of this document may be reproduced, altered, stored or transmitted by any person without the prior written consent of ARTC. May 2005 Page 2 of 10

About This Standard This Specification describes the specific requirements for Power Supply Units (DC Regulated and Filtered) to be manufactured and supplied to Australian Rail Track Corporation (ARTC) or contractors to Australian Rail Track Corporation, for Signalling applications. May 2005 Page 3 of 10

Document History Primary Source RIC Standard SC 09 10 07 00 SP Version 3.0 List of Amendments ISSUE DATE CLAUSE DESCRIPTION 1.1 01/09/2004 Reformatting to ARTC Standard 1.2 14/03/2005 Disclaimer Minor editorial change 1.3 06/05/2005 All Document reformatted May 2005 Page 4 of 10

Contents 1. Introduction...6 2. Applicable Documents...6 2.1 ARTC Specifications...6 3. Electrical Requirements...6 3.1 Input Voltage...6 3.2 Output Voltage...6 3.3 Adjustment...6 3.4 Output Rating...7 3.5 Output Ripple...7 3.6 Output Impedance...7 3.7 Transformer...7 3.8 Rectifier...7 3.9 Capacitor...7 3.10 Protection...7 3.11 Transient Protection...8 3.12 Temperature Variation...8 4. Design Requirements...8 4.1 Standardization of components...8 4.2 Maintenance...8 4.3 Assembly...8 4.4 Rating of Components...9 4.5 Terminations...9 4.6 Case Details...9 Drawings attached...10 May 2005 Page 5 of 10

1. Introduction This Specification describes the specific requirements for Power Supply Units (DC Regulated and Filtered) to be manufactured and supplied to Australian Rail Track Corporation (ARTC) or contractors to Australian Rail Track Corporation, for Signalling applications. 2. Applicable Documents 2.1 ARTC Specifications This Specification refers to the following ARTC Specifications: Specification. SPS 22 Specification SPS 05 Power Supply Units for Signalling Equipment - General Requirements. Ratings of Components Construction Requirements. 3. Electrical Requirements ARTC IDENTITY DC701 ITEM DESCRIPTION Power Supply Unit-regulated 24V, 4A DC OLD(SRA) ID SPECIFICATION (Store 93) SPS 30 All components shall meet the requirements of Specification SPS 05. 3.1 Input Voltage The unit will be operated from a nominal 120Volts, supply with input 50Hz voltage variation from 110 Volts to 125 Volts (conditions of Specification SPS 22 are not applicable to this item). 3.2 Output Voltage The output voltage shall be 24 Volts D.C. nominal and shall be regulated to +/- 0.5V. No variation outside this range shall occur for changes in load conditions from 10% load to 100% load and/or changes in input voltage over the range stated in clause 3.1. In addition the units shall be designed so that the output voltage does not exceed 28 Volts nor reverses polarity during any switching on or off of the input A.C. supply or of the load. The output shall be protected as specified in clause 3.10 and 3.11. 3.3 Adjustment The units shall be designed to operate over the full input and output voltage ranges without the need for adjustment of input and output tappings. However, designs may be submitted which utilise adjustable settings provided that they meet or better the following requirements: a) Once the output voltage has been set at 24 +0.5Volts for a constant load between 0 and 4A, then the unit shall hold its output voltage within the range specified in clause 2.2 for an input voltage of 110V to 125V. May 2005 Page 6 of 10

b) Full details of the various settings shall be provided including the voltage range accepted on each setting. 3.4 Output Rating The unit shall be capable of supplying a continuous load of 4A at the specified output voltage of 24V over the full range of specified input voltages and ambient temperature. 3.5 Output Ripple The unit shall be provided with filter so that the output ripple does not exceed 0.3V peak to peak for all load conditions from zero load to full rated load. 3.6 Output Impedance The supply unit shall have a low output impedance so that the unit is representative of a secondary battery supply. If possible the output impedance shall be 10milliohms or lower when connected to an equipment that works directly from 24Volts D.C. and produces or receives frequencies between 1600 and 2700Hz. Details of the output impedance of the unit offered shall be included with the quotation. 3.7 Transformer Refer to Specification SPS 05. The transformer shall comply with AS 2374 3.8 Rectifier Refer to Specification SPS 05. The rectifier shall be able to supply the surge current of the smoothing capacitor without sustaining damage. The rectifier shall have a minimum Peak Inverse Voltage of 1KV. 3.9 Capacitor Refer to Specification SPS 05. Electrolytic capacitors shall be rated at least 50V D.C. The capacitor shall be a long life industrial grade. The capacitor shall be mounted in a ventilated location. 3.10 Protection The supply unit shall be fitted with automatic current limiting facilities, which shall become effective if the maximum load specified in clause 3.4 is exceeded. The protection shall not rely on high-speed fuses or other similar devices on the input or output. The unit shall be capable of correct operation as soon as the overload is removed without the need for any manual resetting or adjusting. This protection shall be capable of withstanding a continuous short circuit on the output terminals without affecting the supply unit and it shall not cause the fuse on the 120V input to blow. A protective fuse is not required on the 120V input as this will be provided by ARTC and will be mounted externally to the unit. May 2005 Page 7 of 10

However, the suggested rating of this external fuse, along with an absolute maximum rating for this fuse, shall be notified at time of supply. This is to enable ARTC to use a suitably rated fuse from its standard range. The voltage during switching transients shall never exceed 28 Volts. 3.11 Transient Protection The equipment will be subject to all transients which would be present in normal commercial 50Hz supplies. A changeover contactor will be used to switch to alternate 50Hz supplies in the event that the normal supply is interrupted and this can generate considerable transients. During the change over there will be break in the 120V input supply which can last up to 100 milliseconds. The equipment shall be designed so that the output voltage and any transients do not exceed 28 Volts when input is re-applied. It shall be noted that when changing between the two 120V input supplies that these may not be in phase and the unit shall be designed to accommodate this fact. Any transients appearing on the 120V supply shall not cause the output voltage to exceed 28V or to reverse polarity, nor shall these cause damage to the power supply unit itself. Similarly, the D.C. output side of the unit shall be protected against transients which may be generated by solenoid, motors, relays and other inductive loads. Full details of the level of protection offered against transients shall be included with the quotation. 3.12 Temperature Variation The unit shall be suitable for operation in an environment where the ambients vary from -5 degree C to +70 degree C. 4. Design Requirements 4.1 Standardization of components Refer to Specification SPS 22. 4.2 Maintenance Refer to Specification SPS 22. The method of mounting of the unit on the rack as per drawing M08-429 must be quick and simple. The unit shall be capable of supporting itself on the rack while being secured. 4.3 Assembly Refer clause 4.3 of the Specification SPS 22. All components shall be firmly supported to withstand vibration without damage to connections or terminals. May 2005 Page 8 of 10

4.4 Rating of Components All components shall be capable of withstanding vibration without damage or loss of efficiency and shall be of the highest quality. They shall not be operated in excess of the following requirements. (i) (ii) (iii) Electronic Components:50% of nominal voltage breakdown, current and power ratings. All Wiring:50% of nominal ratings and is to be 0.6/1KV. All Others:75% of nominal ratings. 4.5 Terminations All input and output wiring shall be terminated in a readily accessible position on "Klippon" BK or an approved equivalent type terminals. 4.6 Case Details Refer to Specification SPS 22. The complete unit shall be mounted in a single fully enclosed ventilated metal case provided with mounting holes suitable for rack mounting on racks. The terminals shall be external to the unit. (Refer to drawing M08-429 for verification of the positioning of terminal blocks) The mounting holes shall be large enough to accept 5mm diameter screws and shall not exceed the dimensions of the rack as shown on the drawing. May 2005 Page 9 of 10

Drawings attached M08-429: Standard rack layout for equipment May 2005 Page 10 of 10