VCU Radiation Oncology

Similar documents
Geant4 in Brachytherapy

An EGSnrc generated TG-43 dosimetry parameter database

Basics of treatment planning II

ELECTRON DOSE KERNELS TO ACCOUNT FOR SECONDARY PARTICLE TRANSPORT IN DETERMINISTIC SIMULATIONS

GPU Based Convolution/Superposition Dose Calculation

Current status of the benchmark cases with plans for availability to the medical physics community

Michael Speiser, Ph.D.

Basic Radiation Oncology Physics

Proton dose calculation algorithms and configuration data

Electron Dose Kernels (EDK) for Secondary Particle Transport in Deterministic Simulations

Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.

CBCT Equivalent Source Generation Using HVL and Beam Profile Measurements. Johnny Little PSM - Medical Physics Graduate Student University of Arizona

ACE Advanced Collapsed cone Engine

Indrin Chetty Henry Ford Hospital Detroit, MI. AAPM Annual Meeting Houston 7:30-8:25 Mon 08/07/28 1/30

Introduction to Biomedical Imaging

Prospects for model-based dosecalculation. work on speed and accuracy

Air Kerma Strength Measurements and Monte Carlo based Dosimetric Characterization of a directional Pd 103 planar source array.

Monte Carlo simulations

particle transport code with Monte Carlo for intercavitary brachytherapy of the cervix uteri

A fast, independent dose check of HDR plans

DUAL energy X-ray radiography [1] can be used to separate

gpmc: GPU-Based Monte Carlo Dose Calculation for Proton Radiotherapy Xun Jia 8/7/2013

Application of MCNP Code in Shielding Design for Radioactive Sources

UNCOMPROMISING QUALITY

VCU Radiation Oncology

Shielding factors for traditional safety glasses

Investigation of tilted dose kernels for portal dose prediction in a-si electronic portal imagers

Comparison of internal and external dose conversion factors using ICRP adult male and MEET Man voxel model phantoms.

What is Monte Carlo Modeling*?

Dosimetry Simulations with the UF-B Series Phantoms using the PENTRAN-MP Code System

Digital Image Processing

Image Acquisition Systems

Interface Dosimetry for Electronic Brachytherapy Intracavitary Breast Balloon Applicators

GPU applications in Cancer Radiation Therapy at UCSD. Steve Jiang, UCSD Radiation Oncology Amit Majumdar, SDSC Dongju (DJ) Choi, SDSC

Scatter Correction Methods in Dimensional CT

Improved Detector Response Characterization Method in ISOCS and LabSOCS

Ch. 4 Physical Principles of CT

Comprehensive treatment planning for brachytherapy. Advanced planning made easy

DETERMINISTIC 3D RADIATION TRANSPORT SIMULATION FOR DOSE DISTRIBUTION AND ORGAN DOSE EVALUATION IN DIAGNOSTIC CT

Monte Carlo methods in proton beam radiation therapy. Harald Paganetti

Measurement of Skin Dose

CT vs. VolumeScope: image quality and dose comparison

NKS GammaUser

Model-Based Dose Calculation Algorithms in Brachytherapy

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

1. Particle Scattering. Cogito ergo sum, i.e. Je pense, donc je suis. - René Descartes

Evaluation of Spectrum Mismatching using Spectrum Binning Approach for Statistical Polychromatic Reconstruction in CT

Monte Carlo simulations. Lesson FYSKJM4710 Eirik Malinen

Monte Carlo Simulation for Neptun 10 PC Medical Linear Accelerator and Calculations of Electron Beam Parameters

Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition

Transitioning from pencil beam to Monte Carlo for electron dose calculations

Integral transport based deterministic brachytherapy dose calculations

- Volume Rendering -

Metal Artifact Reduction CT Techniques. Tobias Dietrich University Hospital Balgrist University of Zurich Switzerland

Digital Imaging and Communications in Medicine (DICOM) Supplement 176: Second Generation Radiotherapy. Additional RT Treatment Modalities

Breaking Through the Barriers to GPU Accelerated Monte Carlo Particle Transport

Effects of the difference in tube voltage of the CT scanner on. dose calculation

OBJECT ORIENTED DESIGN OF ANTHROPOMORPHIC PHANTOMS AND GEANT4-BASED IMPLEMENTATIONS ABSTRACT

Radiation Oncology treatment facility design. Simulators, CT scanners, HDR Brachytherapy

Corso di laurea in Fisica A.A Fisica Medica 5 SPECT, PET

Monte-Carlo modeling used to simulate propagation of photons in a medium

- Volume Rendering -

The IORT Treatment Planning System. radiance. GMV, 2012 Property of GMV All rights reserved

Dose Calculations: Where and How to Calculate Dose. Allen Holder Trinity University.

Chapter 9 Field Shaping: Scanning Beam

SHIELDING DEPTH DETERMINATION OF COBALT PHOTON SHOWER THROUGH LEAD, ALUMINUM AND AIR USING MONTE CARLO SIMULATION

Digital Imaging and Communications in Medicine (DICOM) Supplement 176: Second Generation Radiotherapy. Additional RT Treatment Modalities

Voxel phantoms and Monte Carlo methods applied to internal and external dose calculations.

Participating Media. Part I: participating media in general. Oskar Elek MFF UK Prague

Brachytherapy Seed and Applicator Localization via Iterative Forward Projection Matching Algorithm using Digital X-ray Projections

The Spherical Harmonics Discrete Ordinate Method for Atmospheric Radiative Transfer

DVH computation comparisons using conventional methods and optimized FFT algorithms for brachytherapy

Monte Carlo Reference Data Sets for Imaging Research

A SYSTEM OF DOSIMETRIC CALCULATIONS

DUAL-ENERGY CT IN PROTON THERAPY

ISOCS Characterization of Sodium Iodide Detectors for Gamma-Ray Spectrometry

Dose Point Kernel calculation and modelling with nuclear medicine dosimetry purposes

Brachytherapy RDTH 3120

Arion: a realistic projection simulator for optimizing laboratory and industrial micro-ct

Voxels and Medical Applications. FLUKA Beginners course

Outline. Outline 7/24/2014. Fast, near real-time, Monte Carlo dose calculations using GPU. Xun Jia Ph.D. GPU Monte Carlo. Clinical Applications

Photon Dose Algorithms and Physics Data Modeling in modern RTP

Disclosure 7/24/2014. Validation of Monte Carlo Simulations For Medical Imaging Experimental validation and the AAPM Task Group 195 Report

Benchmarks of medical dosimetry simulation on the grid

EXTERNAL PHOTON BEAMS: PHYSICAL ASPECTS

arxiv: v2 [cond-mat.mtrl-sci] 5 Jan 2010

C a t p h a n / T h e P h a n t o m L a b o r a t o r y

Image-based Monte Carlo calculations for dosimetry

Introduction to Positron Emission Tomography

Experimental Competition. Sample Solution

Overview of Proposed TG-132 Recommendations

Comparison of Predictions by MCNP and EGSnrc of Radiation Dose

Improvements in Monte Carlo simulation of large electron fields

Influence of electron density spatial distribution and X-ray beam quality during CT simulation on dose calculation accuracy

BME I5000: Biomedical Imaging

An Investigation of a Model of Percentage Depth Dose for Irregularly Shaped Fields

Modeling Radiation Transport Using MCNP6 and Abaqus/CAE Chelsea A. D Angelo, Steven S. McCready, Karen C. Kelley Los Alamos National Laboratory

dq dt I = Irradiance or Light Intensity is Flux Φ per area A (W/m 2 ) Φ =

The OpenGATE Collaboration

Low-Dose Dual-Energy CT for PET Attenuation Correction with Statistical Sinogram Restoration

Transcription:

Semi-empirical Dose-Calculation Models in Brachytherapy AAPM 2005 Summer School 25 July 2004 Jeffrey F. Williamson, Ph.D. VCU Radiation Oncology Virginia Commonwealth University

Semi-Empirical Dose-Calculation Models Mathematical representation of dose distribution Small number of radionuclide-dependent but source-geometry independent parameters No dose measurements needed to implement for a given source History Isotropic point-source kernel and Sievert integral introduced by sievert, Quimby and Parker in 1920 s Displaced by Monte Carlo- and TLD-based table lookup methods in modern era Accurately represents cesium and iridium dose distributions

Model-based Dose Calculation Problem Statement Water-equivalent medium r r D D(r) Ý & Unencapsulated point source of Activity A Isotropic Point Source Air-kerma Strength = S K μgy m 2 /h

2004 AAPM Definition of Air-Kerma Strength K & (d) is air-kerma rate in vacuo due to photons > δ ( 5 kev) d L δ 2 2 1 2 1 S K = K& δ(d) d [ μgy m h = cgy cm h = U] 2 2 ( W) D & air(1 cm) (1 cm) = X(1 & cm) (1 cm) = S K (1 g) S e ( W) = 0.876 cgy/r g = Fx of KE emitted as photons e K

r 1 r 2 Point source emitting P photons Inverse Square Law No.incident photons Φ(r) = Area irradiated Activity P Time = 4πr 2 Dose(r) exposure(r) Φ(r) D(r 1 ) D(r 2 ) = Φ(r 1) Φ(r 2 ) = r 2 r1 2 D& D& med air free space ( ) ( ) ( ) med en en en / = μ ρ μ ρ μ ρ med air air

Tissue Attenuation Factor, T(r) 1.40 Tissue Attenuation Factor, T(r) 1.20 1.00 0.80 0.60 0.40 0.20 137 Cs 198 Au 60 Co 169 Yb: Type 8 Seed 125 I: Model 6702 192 Ir: MicroSelectron HDR Describes competition between primary photon and attenuation and scatter buildup T(r ) = 1 ± 0.05 for r < 5 cm when E >200 kev Often derived from 1- D transport calculations 0.00 0 5 10 15 Distance (cm) D T(r) = Tissue Attenuation Factor = & D & wat wat (r) in Water (r) in Vacuum

Isotropic Point-Source Kernel Assuming air-kerma strength calibration med S K ( μen / ρ) air med 2 D & (r) = T(r) r Assuming contained activity calibration Exposure-rate constant: ( ) Γ = δ x X & (r) r δ A 2 med ( ) ( ) Γδ (W/e) ( μ x en / ρ) air Γδ f x med D & med(r) = A T(r) = A T(r) 2 2 r r

TG-43 and Classical Point-kernel Λ D(1 & cm, π / 2) S g(r) L K wat ( μen / ρ) air T(1 cm) G L(1 cm, π /2) D(r, & π / 2) G L(1 cm, π/ 2) T(r) T(1 cm) D(1 & cm, π/ 2) G (r, π/2) L Generally, CPK and modern Monte Carlo-TLD dosimetry agreement within 2%-3% along transverse-axes of 192 Ir and 137 Cs sources

TLD-MC vs. Classical For 192 Ir Anctil 1998 Valicenti 1995

Y θ' x Δθ θ 1 θ θ 2 y P(r,θ) = P(x,y) Sievert Integral Geometry r r' L X ΔL t ( ) wat air μ t ΔL μen / ρ e Δ D(x,y) & = SK T(x / cos θ)e L 2 (x/cos θ) μ t/cosθ

Sievert Filtered Line-Source Integral wat air μ t ( μen / ρ) e 2 θ μ tsec θ θ D(x,y) & = SK e T(x sec θ) dθ Lx 1 μ = effective filtration coefficient (0.021 to 0.039 mm -1 for Cs-137 and steel ) Best results: treat μ as fitting parameter, not assume μ = μ en L = active length, t = filter thickness Sievert model works well for Cs-137, but >10% errors for lower energy sources off transverse axis

Modern 1D Pathlength Algorithms Integrate CDK over 3D source geometry Actual Geometry Cylindrical Core Ceramic Line Source Steel Line Source

Modern 3D Pathlength Model with Best Fit CDCS-J 1992 Source 3D geometric Model Best Fit Filtration Coef. RMS error: 0.8% -0.9% to 4.1% range

Conventional Sievert Model CDCS-J 1992 Source Ceramic Line Source Model Filtration - μ en RMS error: 3.0% -5.4% to 10.1% range

1D Pathlength Model vs. Monte Carlo 3M 6500 137 Cs Tube 0.30 Model 3M 6500 Source: 2 cm Polar profile 0.29 Dose Rate/Air-Kerma Strength (cgy/h per unit U) 0.28 0.27 0.26 0.25 0.24 Monte Carlo Best fit μ en Best Fit μ en } 3D } Geometry Ceramic Line Source 0.23 0.22 0 30 60 90 120 150 180 Angle (degrees)

1D Pathlength Model: HDR 192 Ir %RMS error = 6.9%

Scatter Separation Model: HDR 192 Ir Williamson IJROBP 1996 %RMS error = 2.9% Max error = 8.9% D(r, & θ ) = primary dose at (r, θ) + transverse axis scatter dose at (r, π/ 2) D(r, & θ ) = D & (r, θ ) + D & (r, π/2) SPR(r) pri pri

Sievert Model: 125 I Seed 0.20 0.10 Best-fit constant filtration coefficients μ Ti = 1.825 mm -1 μ Resin = 0.00 mm -1 Fractional Error 0.00-0.10-0.20 0.25 cm 0.5 cm 1.0 cm 2.0 cm 3.0 cm 5.0 cm 0 30 60 90 120 150 180 Polar Angle (degrees)

Why is 6711 I-125 Λ lower? Classical ( ) med Λ = μ / ρ T(r ) en 0 air = 1.012 1.012 = 1.024 1995 TG-43 Λ 85N,95D = 0.88 15% lower! 1985 NIST S K Standard contaminated by 4.5 kev Ti characteristic xrays (10% effect) Conventional T(r) neglects 22 kev Ag characteristic x rays (5% effect)

1D pathlength Model Shielded Fletcher-Suit Colpostat Weeks 1998: Best-fit μ for tungsten Solid Line: MCNP Monte Carlo Broken Line: 1D pathlength model

Recent Model-based Algorithms Scatter separation Williamson 1996: improves accuracy of 192 Ir anisotropy functions Superposition/Convolution Williamson 1991; Carlsson 2000 Accurate but slow Boltzmann transport equation solutions Discrete ordinates: Daskalov/Williamson Fast Monte Carlo: Le 2005, Chibani 2005 Integral transport: Zhou 2004

Current single-source dose superposition algorithm: patients are composed of homogeneous liquid water Cs-137 & Ir-192 sources: 15%- 50% applicator, shielding, bounded scatter-volume effects Pd-103/I-125 interstitial sources: 5%-50% interseed attenuation and tissue inhomogeneity effects 2005 Virginia Commonwealth University

Tissue Heterogeneity Effects 78 Model 6711 125 I seeds Single-Energy CT Material Analysis (CTcreate) Z-AXIS (cm) -10-8 -6 (A) (B) 2D dose ratio D hete /D homo 2.5 2 1.5 2.5 2 1.5 1 profile A profile B profile C -4 (C) 8.5 10.5 12.5 14.5 16.5 X-AXIS (cm) 1 0.5 0 8.5 10.5 12.5 14.5 16.5 2005 Virginia Commonwealth University

Efficiency Performance LINUX with single Xeon 3.0 GHz processor Geometry Code % σ Time (min) 77 64 81 PTRAN_744 1.5 412 1 1 1mm 3 PTAN_CT 1.5 71 42 35 45 PTRAN_744 1.5 76 2 2 2mm 3 PTAN_CT 1.5 15 30 30 30 PTRAN_744 1.5 35 2 2 2mm 3 PTAN_CT 1.5 6 Prostate 2 2 2mm 3 PTAN_CT 2 2 PTRAN_CT vs. PTRAN: 5 times more efficient 2005 Virginia Commonwealth University

PTRAN_CT Features Precomputed Phase space source Primary photons tracked to surface of source/applicator with unit weight saved. Used to initialize photon histories during patient simulations Ray tracing Fast parametric ray tracing through voxel grid (Siddon 1985) Preprocessing: identifies voxels that intersect seeds and applicators Analytic ray tracing limited to applicators contiguous to intersected voxels Fast algorithm for merging analytic and voxel path lengths

Phase Space Concept Precomputed singlesource histories Effective primary photons for patient simulation

PTRAN_CT Ray Tracing Analytic Ray Tracing + Voxel grid Tracing 4 regions and 8 surfaces/ 6711 seed x 78 seeds = Voxel grid Ray Tracing 77 64 81 grid = 400K cells integrated Ray Tracing

Conclusions Isotropic point-kernel and 1D pathlength models are accurate TG 43 alternatives Interstitial seeds 192 Ir photon energies 137 Cs intracavitary tubes and shielded colpostats including 2D anisotropy 192 Ir anisotropy functions when 1D pathlength + scatter separation is used Semi-empirical model limitations Require careful benchmarking against Monte Carlo to validate for a class of problems Not validated for lower-energy sources More sophisticated models may not be competitive with Monte Carlo dose-calculation engines

The Future: Monte Carlo-based Dose-Calculation Subminute Monte Carlo dose calculation for full clinical implant geometries possible Implementation issues More complex applicator/seed localization RTP input will be source/applicator geometry or phase space, not single-source dose distribution Prostate/low energy seed issues How to measure tissue composition? dual-energy CT? CT artifact mitigation» Urethral contrast biases MC» Streaking artifacts from seeds mimic bone

Tandem & Colpostat Localization Lerma: Med Phys 29:325 2001 Weeks CT-compatible applicators with aluminum bodies, afterloading tungsten shields, & Cs-137 tubes Find applicator pose that maximizes coincidence of Monte Carlo applicator geometry with CT contours of applicators