CHAPTER/REGIONAL TECHNOLOGY AWARD - SHORT FORM

Similar documents
ASHRAE CHAPTER TECHNOLOGY AWARD Illinois Chapter, Region VI

Energy Engineering: Tools and Trends

AIR-COOLED A (Surprisingly) Cost-Effective Alternative to Water-Cooled Chiller Plants

Trane Engineering News Chiller Plant Case Study: Variable-Primary Flow Series Chillers with Free Cooling

Silicon Valley Power Data Center Program Rebate Application

where we are, where we could be, how we can get there. 12/14/2011

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

Trailblazer AGZ-E air-cooled scroll chillers

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

UC DAVIS THERMAL ENERGY STORAGE (TES) TANK OPTIMIZATION INVESTIGATION MATTHEW KALLERUD, DANNY NIP, MIANFENG ZHANG TTP289A JUNE 2012

Data Center Energy Savings By the numbers

DATA CENTER EFFICIENCY: Data Center Temperature Set-point Impact on Cooling Efficiency

that may have a direct effect on your bottom line. The question

CRAH Retrofit and Energy Savings Project

Presentation. Guaranteed Energy Savings Performance Project

Air-Cooled Series R Chiller

Prescriptive Program Rebate Application

REPORT. Energy Efficiency of the San Diego Supercomputer Center and Distributed Data Centers at UCSD. Prepared for:

Retro-Commissioning Report

2017 NEHES Fall Conference Technical Breakout Session: Deep Chiller Plant Optimization

CASE STUDIES. Brevard Community College: Florida Power & Light. Cape Canaveral Air Force Station: NORESCO

WHAT IS THE DIGI-RTU South 59 th Street Omaha, NE bes-tech.net

Trane mytest Water-cooled Chiller Performance Validation What you spec is what you get *

Achieving Operational Excellence

DEDICATED HEAT RECOVERY UNIT (DHRC)

Fair City Plaza. Task: Diagnose problems, recommend improvements for small municipal district cooling system

LIFE CYCLE COST ANALYSIS, CRITERIA AND DATA SHEETS DOCUMENT NUMBER: APPLICATION: ELEMENTARY, MIDDLE AND HIGH SCHOOL

MSYS 4480 AC Systems Winter 2015

Next Generation DCP Optimization using MV VSDs

2018 Business Cooling Equipment Rebate Application

Energy Action Plan 2015

IN-DEPTH UNDERSTANDING OF HVAC EQUIPMENT & SYSTEM SPECIFICATIONS AND PERFORMANCE 11 & 12 JULY 2016 WISMA IEM

FLORIDA STATE UNIVERSITY MASTER PLAN 10 Utilities

Concord Hospital Infrastructure Upgrades Increased Energy and Operating Efficiencies with a Tangible Reduction in Operating Costs

Data Centers. Powerful Solutions That Put You in Control. Energy Management Solutions. Where your energy dollars are used. 1

Energy Management of the Refrigeration Systems at Zurich Airport. Burkhard Bein. Schaffhausen,

Must possess Universal EPA Section 608 certification; OR Type I AND Type II EPA Section 608 certification.

BAS Chillers 8/15/2016. Achieving Energy Savings with BAS and Data Analytics Guanjing Lin Lawrence Berkeley National Laboratory August 10, 2016

CenterPoint Energy Retro-Commissioning Program Application

ISO 50001/SEP. Superior Energy Performance at Schneider Electric. Design the Strategy Deliver Efficiency Sustain Results

Building Tune-Up Program Application

PROCESS COOLING STUDY WORKSHEET

energy solutions MEASUREMENT &VERIFICATION& ELLEN FRANCONI, ROCKY MOUNTAIN INSTITUTE,

Comprehensive Energy Management & Utility Master Plan

DCIM Data Center Infrastructure Management

Designing Ultra-Efficient Building Cooling Systems

Welcome. Hardeep Singh Service and Parts Director Trane Middle East & Africa

Efficiency Works Business: 2017 Rebates & Goals. January 17, 2017

White Paper: Data Center Capacity Management Provides New Business Opportunities & Efficiency at State-of-the-Art One Wilshire June 8, 2017

Is Data Center Free Cooling Feasible in the Middle East? By Noriel Ong, ASEAN Eng., PMP, ATD, PQP

The City of Seattle s Mandatory Benchmarking and Disclosure Program

Engineered Energy Solutions An Overview. Controls, Automation and Energy Conservation

Driving Proactive Facility Operations with Automated HVAC Diagnostics

1.0 Executive Summary. 2.0 Available Features & Benefits

SCHENDT ENGINEERING PRIOR EXPERIENCE

Agenda Date: 8/23/17 Agenda Item: SB CLEAN ENERGY

Streamlining Utility Billing Analysis and Reporting. Dagoberto Rodriguez, Energy Manager Marlene Z Rosenboom, Utility Analyst

BCPro System Product Bulletin

Magnitude magnetic bearing centrifugal chillers

18 th National Award for Excellence in Energy Management. July 27, 2017

a) Provision of a chilled water supply b) Provision of electric power supply and other fuels

T66 Central Utility Building (CUB) Control System Reliability, Optimization & Demand Management

Fault Detection and Diagnostic Software

Magnitude magnetic bearing centrifugal chillers

Introducing the Heat Wheel to the Data Center

Efficiency of Data Center cooling

Date: 26th August 2017 Presented By: Pinaki Mukherjee, Sudeep Saha

Analyze and Implement: Modernizing an Airport Central Utility Plant

DEEMED SAVINGS TECHNICAL ASSUMPTIONS

SUSTAINABLE SAUNDERS AC SHUTDOWN PROJECT

Cleanroom Energy Benchmarking In High-Tech and Biotech Industries

100% Warm-Water Cooling with CoolMUC-3

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Dykin Engineering Part & Services Sdn. Bhd.

30XAV & 30XWV. Air and water-sourced, variable-speed screw units. AquaForce with Greenspeed intelligence, Because you should not have to choose.

HVAC Incentives Application Energy Solutions for Business

Ft Worth Data Center Power Metering for Real Time PUE Calculation. Scope of Work

SME License Order Working Group Update - Webinar #3 Call in number:

HIGH EFFICIENCY Central Chiller

CARRIER edesign SUITE NEWS

Green IT Project: The Business Case

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

Advanced RTU Campaign Technical Resources: Evaluating Performance December 10, 2013

Commercial Retro-Commissioning Program Manual for 2016 SECTION 1

ASHRAE. Shaping Tomorrow s Built Environment Today

Optimiz Chilled January 25, 2013

Oil Free Magnetic Bearing Chillers. Lloyd Davis ESTech Energy Ltd

HOURLY ANALYSIS PROGRAM v5.00 and v5.01

REPORT TO THE BUSINESS ADMINISTRATION COMMITTEE

CARRIER HOURLY ANALYSIS PROGRAM v5.0

Chiller Replacement and System Strategy. Colin Berry Account Manager

Evaluation and Modeling of Data Center Energy Efficiency Measures for an Existing Office Building

E e n rgy g y St S ud u y y Pr P og o r g ams December 2011

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Overview of Danfoss Turbocor. Danfoss Turbocor Learning Center M110_v4

Beverly D. Grappone Hall Certified LEED Silver Home of NHTI s State-of-the Art Nursing Simulation Center

Large Tonnage Chillers. Kingsley Hu Technical Support Engineer

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

Retrofit Suppliers Workshop: Making the Effective Pitch December 4, :30am 12:00pm

SRP Energy Efficiency Program Update SWEEP Regional Energy Efficiency Workshop

Transcription:

CHAPTER/REGIONAL TECHNOLOGY AWARD - SHORT FORM 1. Category (Check one and indicate New or Existing, if applicable) Commercial Buildings New or Existing Institutional Buildings: Educational Facilities New or Existing Other Institutional New or Existing Health Care Facilities New or Existing Industrial Facilities or Processes New or Existing Public Assembly New or Existing Residential (Single and Multi-Family) 2. Name of building or project: City/State: Advocate Illinois Masonic Medical Center Chicago, IL 3. Project Description: Chiller Replacements Project Study/Design Period: 09/2011 to 09/2013 Begin date (mm/yyyy) End date (mm/yyyy) Percent Occupancy at time of submission: 100% 4. Entrant (ASHRAE member with significant role in project): a. Name: Doyle Daniel L Last First Middle Membership Number: Chapter: Region: b. Address (including country): Evanston 192578 Illinois IV 820 Davis St., Suite 300 IL 60201 United States City State Zip Country c. Telephone: (O) 847-316-9219 d. Email: ddoyle@grummanbutkus.com e. Member s Role in Project: Mechanical and Electrical Design f. Member s Signature: 5. Engineer of Record: Grumman/Butkus Associates By affixing my signature above, I certify that the information contained in this application is accurate to the best of my knowledge. In addition, I certify that I have discussed this entry with the owner and have received permission from the owner to submit this project to the ASHRAE Technology Awards Competition.

2013 AWARD ENTRY Illinois Chapter of ASHRAE Excellence in Engineering Advocate Illinois Masonic Medical Center Chiller Plant Replacement Grumman/Butkus Associates Energy Efficiency Consultants and Sustainable Design Engineers 820 Davis Street, Suite 300 Evanston, IL 60201.4446 847 328.3555 FAX 328.4550 2012 Grumman/Butkus Associates Illinois Professional Registration #184-000926

Illinois Masonic Medical Center Chiller Plant Replacement Project Narrative Grumman/Butkus Associates Advocate Illinois Masonic Medical Center (AIMMC) is a 1,143,379 square foot hospital located on the north side of Chicago. AIMMC is part of the Advocate Health Care network of hospitals and has been serving the neighborhood for over 100 years. AIMMC pursued this project in order to provide a more reliable cooling system, improve energy efficiency, reduce staff labor related to maintaining the chiller plant, and modernize the equipment in regards to refrigerant management in compliance with the Montreal Protocol. The project included replacement of the three main chillers serving the hospital, as well as new pumps and cooling towers. An additional air-cooled surgery chiller was replaced. Budget remained at the end of the project allowing for replacement of three additional air-cooled chillers, bringing all of the major chillers at the main hospital into compliance with the Montreal Protocol and significantly improving energy efficiency. Implementation of the project began with AIMMC in consultation with Grumman/Butkus Associates (G/BA) in developing a master plan for the cooling systems, as well as creation of an infrastructure report card to prioritize replacement of major HVAC equipment at the hospital. The project proceeded through design utilizing and equipment pre-purchase arrangement in order to reduce total costs of the project as well as shorten the timeline and optimize energy efficiency. This required cooperation between the owner, G/BA, and the contractor. G/BA provided assistance after the project s installation to verify energy performance reductions in conjunction with Advocate, as well as recouping over $260K in project costs through incentives from ComEd which assisted in obtaining high-efficiency chillers. Energy Efficiency IMMC installed three very efficient magnetic bearing chillers to replace the existing machines. The new chillers are rated at a full load efficiency of 0.572 kw/ton and an NPLV of 0.339 kw/ton. The smaller air cooled chillers also qualified for ComEd incentives for exceeding IECC 2009 requirements. Actual metered data shows that total plant (including chillers, pumps, cooling towers) running at 0.672 kw/ton on a design day. During milder weather, the plant can be seen operating around 0.46 kw/ton. The full load electric demand of the main chiller plant dropped by 200 kw (see attached graph), with the new aircooled machines and primary only pumping configuration, this is further reduced. Whole facility electricity usage data indicated a large reduction during the 2013 cooling season, approximately 1,000,000 kwh for the period covering June, July, and August. Additional savings will accrue in September 2013 due to the hot weather that extended into the fall period for which the billing data is not yet available. Energy savings are just under $80,000 to date. Wee the two attached graphs to further illustrate the savings. Indoor Air quality The project increases the reliability of the cooling systems so that patient care may be maintained with continued high level of indoor air quality in support of the overall health care environment. Innovation Three new high efficiency, 700 ton chillers with VFD s and magnetic bearing compressors were installed. The design included the conversion of the cooling system to variable primary flow configuration from a primary/secondary arrangement. This reduced the project cost and saved space by eliminating half the existing CHW pumps. The design also included the installation of all new premium efficiency motors. The design of the new cooling towers included the installation of new variable frequency drives. The full load design temperature difference was increased from 10 F to 12 F to further reduce flow and pumping energy usage. Four existing air-cooled chillers were replaced w/ new high efficiency chillers. The new chillers include: 250 tons (EER 9.9, IPLV EER 19.3) 1

Two 170 ton units (EER 9.4, IPLV EER 17.3) 90 tons (EER 9.7, IPLV EER 15.4) The innovative design aided in solving spatial constraint issues, as the project included the re-use of the existing chiller mechanical room. The conversion to variable-primary flow eliminated one set of pumps from the replacement design. Additionally, in-line pumps were used to save space where new base-mounted pumps would not fit in the available area. The installation of the three identical chillers, minimization of floor space, fresh paint and new LED lighting resulted in an aesthetically attractive chiller room. Operation & Maintenance The new chillers were selected using life-cycle cost analysis to minimize total cost of ownership owner the next 30 years. The new design includes a number of features to enhance flexibility by the facility operations staff. 1. Main chiller plant now has N+1 redundancy on refrigeration machines. 2. Three main chilled water pumps installed on a header allowing any one pump to be out of service at any time. One pump is always available as a standby pump. 3. Condenser water pumps are also on a common header so that any one pump may be out of service. These also were installed with VFD s to minimize pressure losses related to balancing of the system. 4. Air-cooled chiller for the surgery AHU may be cross-tied to the main chilled water system as a backup for the surgery AHUs. The chiller has multiple compressor circuits which allows for part-load operation of the chiller if one compressor is out of service. 5. Air-cooled chillers with capacities of 170 tones, 170 tons, and 90 tons were installed for other high internal load areas of the hospital so that the main chiller plant does not need to operate year-round. These chillers also have multiple circuits which allow a level of redundancy that was not available in the existing equipment. Control upgrades installed with the new chillers will allow more efficient use of operations staff resources, in addition to improved reliability requiring fewer service tickets. Cost Effectiveness Advocate revised the project to better meet the needs of the hospital with the available budget of $4,420,000. Remaining budget towards the end of the project allowed for replacement of additional air-cooled chillers that what was in the original project scope. G/BA assisted the client in obtaining ComEd rebates as a result of the new energy efficient design. The rebates included: ComEd Incentives 250 ton-air-cooled chiller & pump VFD s - $ 28,525 170 ton air-cooled chillers - $ 31,640 90 ton air-cooled chillers - $ 5,252 Three 700 ton centrifugal chillers, pump VFD s and cooling tower fan VFD s - $203,700. The project resulted in estimated energy savings of over $85,000 per year. Cooling coil condensate from the air handlers in the fan room adjacent to the cooling towers is used for colling tower make-up water. This feature saved 450,563 gallons of water during the last cooling season, and reduced the amount of chemicals used for water treatment. Environmental Impact The new chillers utilize refrigerant with no ozone depletion potential. 2

Illinois Masonic Medical Center Chiller Plant Replacement Project Narrative Graphics The linear curve fit shows approximately 200 kw reduction on average when temperatures are 95 F outside. This does not include the air-cooled chillers. 90,000 80,000 70,000 Monthly Electricity Use (kwh/day) 60,000 50,000 40,000 30,000 20,000 2011 2013 10,000 0 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Figure 1: IMMC Monthly Electricity Usage per Day 1,400 1,200 1,000 2012 kw 2013 kw Meter Demand (kw) 800 600 400 200 0 55.0 65.0 75.0 85.0 95.0 105.0 Outside Air Dry-Bulb Temperature ( F) Figure 2: Hourly Power and Temperature

Illinois Masonic Medical Center Chiller Plant Replacement Attachment Project Photos New Cooling Towers Space-saving Pump Design and Installation 2013 Grumman/Butkus Associates M:\Awards\ASHRAE Awards\2013 Award Entry\IMMC Chiller Plant.doc 3