E-STOP relays, safety gate monitors

Similar documents
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relay, safety gate monitor

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Two-hand control unit

Two-hand control unit

Contact expander modules

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Two-hand control unit

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Safe timer relay/contact expansion modules

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

E-STOP relays, safety gate monitors

Safe monitoring relays

E-STOP relay, safety gate monitor

E-STOP relays, safety gate monitors

E-STOP relay, safety gate monitor

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

Safe timer relay/contact expansion modules

Safety relays PNOZsigma

E-STOP relays, safety gate monitors

Safe monitoring relays

Products. Base units PNOZmulti Base units PNOZmulti PNOZ m0p (ETH) PNOZ m1p (ETH) PNOZ m2p (ETH) PNOZ m3p (ETH) 2.

20 inputs for connecting, for example:

Can be configured in the PNOZmulti Configurator Semiconductor outputs: or 4 safety outputs in accordance with EN 954-1, Cat. 3

Speed Monitor. Up to PL e of EN ISO PNOZ s30. Unit features

PNOZ s1. Safety relays. Operating Manual EN-07

PNOZ s2. Safety relays. Operating Manual EN-07

PNOZ s9. Safety relays. Operating Manual EN-08

Faults on the system Proximity switch connection technology:

Datasheet - SRB 402EM-24V

PNOZ X1. } Safety relays. Operating Manual EN-08

PNOZ X2.1. } Safety relays. Operating Manual EN-05

Electronic monitoring relays PMDsrange

Datasheet - SRB 301LC/B-24V

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Datasheet SRB301ST 24V (V.2)

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Datasheet - SLB 200-C04-1R

Safety Technique. SAFEMASTER C Multifunction Safety Module BH 5910

PNOZ m EF 8DI4DO. Configurable Control System PNOZmulti. Operating Manual EN 02

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

MSR178DP. Description. Features. Specifications

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Safety Technique. SAFEMASTER C Multifunctional Safety Timer UG 6960

Two-hand relay modules SRB 201ZH 44 Schmersal Industrial switching systems

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

PSEN 4.2a/b/p/M12. PSEN sensor technology. Operating Manual EN-02

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Safety Technique. SAFEMASTER Light Curtain Controller With Selectable Operating Modes BH 5902/01MF2

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

PHOENIX CONTACT Features

PSR UC/ESAM4/3X1/1X2/B

Installation / Control Technique

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

PSR DC/ESP4/2X1/1X2

PNOZ ml1p. PNOZmulti Modular Safety System. Operating Manual No EN-05

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

MINI-PS AC/10-15DC/8

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Vital. Safety controller. Approvals: Control of: Features: Entire safety system based on the dynamic safety circuit.

Electronic timer CT-ERD.12

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Datasheet - AZM 200SK-T-1P2PW

SALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT

Safety Technique. SAFEMASTER C Multifunctional Safety Timer UG 6961

ENGLISH. Terminals 13, 14, 23, 24, 43, 44, 53, Web: Phone: Toll Free:

Dold BH5928 Series 2-Channel Emergency Stop and Safety Gates with Delay

PNOZ m EF PDP Link. Configurable Control System PNOZmulti. Operating Manual EN 02

Safety relay emergency stop/protective door, 230VAC, 3 enabling paths

Transcription:

Unit features Safety features Gertebild ][Bildunterschrift_nur_Not-Halt Safety relay for monitoring E-STOP pushbuttons Approvals Gertemerkmale Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Connection options for: E-STOP pushbutton Reset button LED indicator for: Switch status channel 1/2 Supply voltage Plug-in connection terminals (either spring-loaded terminal or screw terminal) Unit description ][Sicherheitseigenschaften Schaltgerät_allgemeiner Teil The relay meets the following safety requirements: The circuit is redundant with built-in self-monitoring. The safety function remains effective in the case of a component failure. The correct opening and closing of the safety function relays is tested automatically in each on-off cycle. Gertebeschreibung The safety relay is not suitable for noncontact barriers because a dynamic start is not possible Bestimmung/Gerätebeschreibung NOT-AUS, Schutz_PNOZ The safety relay meets the requirements of EN 60947-5-1, EN 60204-1 and VDE 0113-1 and may be used in applications with E-STOP pushbuttons Safety gates Zulassungen Block diagram Blockschaltbild A1 A2 Y1 Y2 13 23 33 41 = = Input Reset/ Start K1 Power K2 14 24 34 42

Function description ][Funktionen_einkanalig_Erd_Start Single-channel operation: no redundancy in the input circuit, earth faults in the reset circuit are detected. Timing diagram ][Funktionen_autoStart Automatic start: Unit is active once the input circuit has been closed. ][Funktionen_manuStart Manual reset: Unit is active once the input circuit is closed and then the reset circuit is closed. ][Funktionen_Kontaktvervielfachung Increase in the number of available instantaneous safety contacts by connecting contact expansion modules or external contactors. ][Zeitdiagram_auto_manu_aux 1 2 a b POWER Reset/Start Input Output safe Output aux. t1 t2 t1 t2 t1 t2 t1 t2 Key Power: Supply voltage Reset/start: Reset circuit Y1-Y2 Input: Input circuits A1 Output safe: Safety contacts 13-14, 23-24, 33-34 Wiring ][Verdrahtung_Si_unverz_1Hi_unverz Please note: Information given in the Technical details must be followed. Outputs 13-14, 23-24, 33-34 are safety contacts, output 41-42 is an auxiliary contact (e.g. for display). To prevent contact welding, a fuse should be connected before the output contacts (see technical details). Calculation of the max. cable runs l max in the input circuit: I max = R lmax R l / km R lmax = max. overall cable resistance (see technical details) R l /km = cable resistance/km Use copper wire that can withstand 60/75 C. Sufficient fuse protection must be provided on all output contacts with capacitive and inductive loads. Output aux: Auxiliary contacts 41-42 : Automatic reset : Manual reset a: Input circuit closes before reset circuit b: Reset circuit closes before input circuit t 1 : Switch-on delay t 2 : Delay-on de-energisation -2

Preparing for operation Betriebsbereitschaft herstellen Supply voltage Supply voltage AC DC A1 L+ A2 L- Input circuit Input circuit Single-channel Dual-channel E-STOP without detection of shorts across contacts S1 A1 L+ Safety gate without detection of shorts across contacts A1 S1 L+ Reset circuit Reset circuit Automatic reset E-STOP wiring (single-channel) Safety gate (single-channel) Y1 E-STOP wiring (dual-channel) Safety gate (dual-channel) Y2 Manual reset Y1 S3 Y2

Feedback loop Feedback loop Automatic reset Manual reset Contacts from external contactors Y1 Y2 13 (23, 33) 14 (24, 34) K5 K6 K5 K6 L1 N Y1 Y2 13 (23, 33) 14 (24,34) K5 S3 K6 K5 K6 L1 N Key S1 S3 E-STOP pushbutton Reset button Switch operated Gate open Gate closed -4

Terminal configuration Klemenbelegung Installation Montage_PNOZ_X The safety relay should be installed in a control cabinet with a protection type of at least IP54. Use the notch on the rear of the unit to attach it to a DIN rail. Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing element (e.g. retaining bracket or an end angle). Dimensions Abmessungen * with spring-loaded terminals 121 (4.76") 94 (3.70") * 101 (3.98") 22,5 (0.88")

Notice ][Wichtig_PDB This data sheet is only intended for use during configuration. Please refer to the operating manual for installation and operation. Service life graph Lebensdauerkurve_Relais_Text vor Kurve The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negligible. D Nennbetriebstrom (A) GB Nominal operating current (A) F Courant coupé (A) E Corriente nominal de servicio (A) I Corrente di esercizio nominale (A) NL Nominale bedrijfsstroom (A) 10 1 DC13: 24 V Lebensdauerkurve AC1: 230 V AC15: 230 V DC1: 24 V 0.1 10 100 1000 10000 D Schaltspielzahl x 10 3 E Número de ciclos x 10 3 GB Cycles x 10 3 I Numero dei cicli di commutazione x 10 3 F Nombre de manœvres x 10 3 NL Aantal schakelingen x 10 3 Lebensdauerkurve_Relais_Text nach Kurve_SF4 Bsp Example Inductive load: 2 A Utilisation category: AC15 Contact service life: 400 000 cycles Provided the application requires fewer than 400 000 cycles, the PFH value (see technical details) can be used in the calculation. To increase the service life, sufficient spark suppression must be provided on all output contacts. With capacitive loads, any power surges that occur must be noted. With contactors, use freewheel diodes for spark suppression. ][Technische Daten PNOZ Technical details Electrical data Supply voltage Supply voltage U B DC 24 V Voltage tolerance -15 %/+10 % Power consumption at U B DC 1.5 W Residual ripple DC 160 % Voltage and current at Input circuit DC: 24.0 V 45.0 ma Reset circuit DC: 24.0 V 45.0 ma Feedback loop DC: 24.0 V 45.0 ma Number of output contacts Safety contacts (S) instantaneous: 3 Auxiliary contacts (N/C): 1-6

Electrical data Utilisation category in accordance with EN 60947-4-1 Safety contacts: AC1 at 240 V I min : 0.01 A, I max : 6.0 A P max : 1500 VA Safety contacts: DC1 at 24 V I min : 0.01 A, I max : 6.0 A P max : 150 W Auxiliary contacts: AC1 at 240 V I min : 0.01 A, I max : 6.0 A P max : 1500 VA Auxiliary contacts: DC1 at 24 V I min : 0.01 A, I max : 6.0 A P max : 150 W Utilisation category in accordance with EN 60947-5-1 Safety contacts: AC15 at 230 V I max : 5.0 A Safety contacts: DC13 at 24 V (6 cycles/min) I max : 4.0 A Auxiliary contacts: AC15 at 230 V I max : 5.0 A Auxiliary contacts: DC13 at 24 V (6 cycles/min) I max : 4.0 A Contact material AgSnO2 + 0.2 µm Au External contact fuse protection (I K = 1 ka) to EN 60947-5-1 Blow-out fuse, quick Safety contacts: 6 A Auxiliary contacts: 6 A Blow-out fuse, slow Safety contacts: 4 A Auxiliary contacts: 4 A Circuit breaker 24 VAC/DC, characteristic B/C Safety contacts: 4 A Auxiliary contacts: 4 A Max. overall cable resistance R lmax input circuits, reset circuits single-channel at U B DC 30 Ohm Safety-related characteristic data PL in accordance with EN ISO 13849-1: 2006 PL e (Cat. 4) Category in accordance with EN 954-1 Cat. 4 SIL CL in accordance with EN IEC 62061 SIL CL 3 PFH in accordance with EN IEC 62061 2.31E-09 SIL in accordance with IEC 61511 SIL 3 PFD in accordance with IEC 61511 2.03E-06 T M [year] in accordance with EN ISO 13849-1: 2006 20 Times Switch-on delay with automatic reset typ. 60 ms with automatic reset max. 120 ms with manual reset typ. 50 ms with manual reset max. 120 ms Delay-on de-energisation with E-STOP typ. 55 ms with E-STOP max. 90 ms with power failure typ. 55 ms with power failure max. 90 ms Recovery time at max. switching frequency 1/s after E-STOP 150 ms after power failure 150 ms Supply interruption before de-energisation 20 ms Environmental data EMC EN 60947-5-1, EN 61000-6-2 Vibration to EN 60068-2-6 Frequency 10-55 Hz Amplitude 0.35 mm Climatic suitability EN 60068-2-78

Environmental data Airgap creepage in accordance with EN 60947-1 Pollution degree 2 Overvoltage category III Rated insulation voltage 250 V Rated impulse withstand voltage 4.00 kv Ambient temperature -10-55 C Storage temperature -40-85 C Protection type Mounting (e.g. cabinet) IP54 Housing IP40 Terminals IP20 Mechanical data Housing material Housing PPO UL 94 V0 Front ABS UL 94 V0 Cross section of external conductors with screw terminals 1 core flexible 0.25-2.50 mm², 24-12 AWG No. 777100 2 core, same cross section, flexible: with crimp connectors, without insulating sleeve 0.25-1.00 mm², 24-16 AWG No. 777100 without crimp connectors or with TWIN crimp connectors 0.20-1.50 mm², 24-16 AWG No. 777100 Torque setting with screw terminals 0.50 Nm No. 777100 Cross section of external conductors with spring-loaded terminals: 0.20-1.50 mm², 24-16 AWG No. 787100 Flexible with/without crimp connectors Spring-loaded terminals: Terminal points per connection 2 No. 787100 Stripping length 8 mm No. 787100 Dimensions Height 101.0 mm No. 787100 94.0 mm No. 777100 Width 22.5 mm Depth 121.0 mm Weight 200 g No. 787100 205 g No. 777100 Technische Daten_Satz No. No. stands for order number. Si-Kennzahlen_Zusatz_Relais_Lebensdauer_PDB It is essential to consider the relay's service life graphs. The relay outputs' safety-related characteristic data is only valid if the values in the service life graphs are met. The PFH value depends on the switching frequency and the load on the relay output. If the service life graphs are not accessible, the stated PFH value can be used irrespective of the switching frequency and the load, as the PFH value already considers the relay's B10d value as well as the failure rates of the other components. Si_Kennzahlen_Erläuterung_1 All the units used within a safety function must be considered when calculating the safety characteristic data. Si_Kennzahlen_Erläuterung_2 INFORMATION A safety function's SIL/PL values are not identical to the SIL/PL values of the units that are used and may be different. We recommend that you use the PAScal software tool to calculate the safety function's SIL/PL values. Technische Daten_Satz Normen The standards current on 2004-09 apply. ][Dauerstrom_DC -8

Conventional thermal current while loading several contacts Number of contacts I th per contact at U B DC 1 6.00 A 2 6.00 A 3 4.50 A Bestelldaten Order reference Type Features Terminals Order no. C 24 VDC Spring-loaded terminals 787 100 24 VDC Screw terminals 777 100