Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

E-STOP relay, safety gate monitor

E-STOP relays, safety gate monitors

E-STOP relay, safety gate monitor

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relay, safety gate monitor

E-STOP relays, safety gate monitors

Safe timer relay/contact expansion modules

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Safety relays PNOZsigma

E-STOP relays, safety gate monitors

Two-hand control unit

Safe monitoring relays

Safe timer relay/contact expansion modules

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Two-hand control unit

Two-hand control unit

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous

Contact expander modules

PNOZ s1. Safety relays. Operating Manual EN-07

Safe monitoring relays

PNOZ s2. Safety relays. Operating Manual EN-07

PNOZ s9. Safety relays. Operating Manual EN-08

Speed Monitor. Up to PL e of EN ISO PNOZ s30. Unit features

Faults on the system Proximity switch connection technology:

Electronic monitoring relays PMDsrange

Datasheet - SRB 402EM-24V

Can be configured in the PNOZmulti Configurator Semiconductor outputs: or 4 safety outputs in accordance with EN 954-1, Cat. 3

20 inputs for connecting, for example:

Datasheet - SRB 301LC/B-24V

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

Products. Base units PNOZmulti Base units PNOZmulti PNOZ m0p (ETH) PNOZ m1p (ETH) PNOZ m2p (ETH) PNOZ m3p (ETH) 2.

PNOZ X1. } Safety relays. Operating Manual EN-08

PNOZ X2.1. } Safety relays. Operating Manual EN-05

Datasheet - SLB 200-C04-1R

Datasheet SRB301ST 24V (V.2)

SECTION 16 LED DIAGNOSTIC FEATURES: EXPANSION UNITS: SCR-31P-i. SCR-73-i. SEU-31-i. SCR-31-42TD-i. SEU-31TD-i

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Two-hand relay modules SRB 201ZH 44 Schmersal Industrial switching systems

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Safety Technique. SAFEMASTER C Multifunction Safety Module BH 5910

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

9926 Series Branch Rated Circuit Breakers AC Version

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

MSR178DP. Description. Features. Specifications

Installation / Control Technique

PHOENIX CONTACT Features

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Safety Relay F 121 Emergency-Stop Relay, Safety Gate Monitor

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

BETRIEBSANLEITUNG TECHNICAL INSTRUCTION INTERFACE PSE2-SC-02 (24 V AC/DC) Version 1.4

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

SNO 4062K SNO 4062KM SNO 4062 K / KM. Circuit diagram. Applications. Function. Function (Continued)

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

MINI-PS AC/10-15DC/8

Safety Technique. SAFEMASTER Light Curtain Controller With Selectable Operating Modes BH 5902/01MF2

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

Electronic timer CT-ERD.12

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

Safety Technique. SAFEMASTER C Multifunctional Safety Timer UG 6960

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

PHOENIX CONTACT - 07/2006

TeSys IEC Contactors and Overload Relays

Introduction Circuit Protection

Electronic timer CT-AHD.22

Contact protection relay

Transcription:

Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 2 safety contacts (N/O), delay-on de-energisation 1 auxiliary contact (N/C), instantaneous Connection options for: E-STOP pushbutton Safety gate limit switch Reset button Delay-on de-energisation can be set separately for both safety contacts with delay-on de-energisation Delay time can be cancelled via reset button LED indicator for: Switch status channel 1/2 Supply voltage Unit description The safety relay meets the requirements of EN 60947-5-1, EN 60204-1 and VDE 0113-1 and may be used in applications with E-STOP pushbuttons Safety gates The max. category the safety contacts can achieve in accordance with EN 954-1 is stated in the technical details. Safety features The relay meets the following safety requirements: The circuit is redundant with built-in self-monitoring. The safety function remains effective in the case of a component failure. The correct opening and closing of the safety function relays is tested automatically in each on-off cycle. The unit has an electronic fuse. Block diagram A1 A2 1 Y36 13 23 33 41 57 67 ~ = Input Input Input K3 K1 Power K4 Feedback Reset/ Start Reset t K2 Y1 Y2 S33 Y39 Y40 14 24 34 42 58 68

Function description Single-channel operation: no redundancy in the input circuit, earth faults in the reset and input circuit are detected. Dual-channel operation without detection of shorts across contacts: redundant input circuit, detects earth faults in the reset and input circuit, Timing diagram short circuits in the input circuit and, with a monitored reset, in the reset circuit too. Dual-channel operation with detection of shorts across contacts: redundant input circuit, detects earth faults in the reset and input circuit, short circuits and shorts between contacts in the input circuit. Automatic start: Unit is active once the input circuit has been closed. Manual reset: Unit is active once the input circuit is closed and then the reset circuit is closed. Increase in the number of available contacts by connecting contact expansion modules or external contactors/relays. POWER Reset/Start Reset t v Input Output safe Output aux Output safe del 1 2 a t1 t2 t3 t1 t2 t3 t1 t2 t3 t1 t2 b t3 Key Power: Supply voltage Reset/start: Reset circuit, S33, Reset t v : Y39-Y40 Input: Input circuits 1-, -, Y36- Output safe: Safety contacts 13-14, 23-24, 33-34 Wiring Please note: Information given in the Technical details must be followed. Outputs 13-14, 23-24, 33-34 are instantaneous safety contacts, outputs 57-58, 67-68 are delay-on deenergisation safety contacts, output 41-42 is an instantaneous auxiliary contact (e.g. for display). To prevent contact welding, a fuse should be connected before the output contacts (see technical details). Calculation of the max. cable runs l max in the input circuit: Output safe del: Safety contacts, delayed 57-58, 67-68 Output aux: Auxiliary contacts 41-42 : Automatic reset : Manual reset a: Input circuit closes before reset circuit I max = R lmax R l / km R lmax = max. overall cable resistance (see technical details) R l /km = cable resistance/km Use copper wire that can withstand 60/75 C. Sufficient fuse protection must be provided on all output contacts with capacitive and inductive loads. b: Reset circuit closes before input circuit t 1 : Switch-on delay t 2 : Delay-on de-energisation inst. contacts t 3 : Delay time -2

Preparing for operation Supply voltage Supply voltage AC DC A1 L+ A2 L- Input circuit Input circuit Single-channel Dual-channel E-STOP without detection of shorts across contacts 1 1 E-STOP with detection of shorts across contacts Y36 1 Safety gate without detection of shorts across contacts 1 1 S2 Safety gate with detection of shorts across contacts Y36 1 S2

Reset circuit Reset circuit Automatic reset E-STOP/safety gate wiring (single-channel and dual-channel without shorts across contacts) S33 E-STOP/safety gate wiring (dual-channel with shorts across contacts) Manual reset S33 S3 S3 Reset delay time Reset Without reset With reset Link or N/C contact Y39 Y39 Y40 Y40 Feedback loop Feedback loop Contacts from external contactors Y1 Y2 13 (23... 67) 14 (24... 68) K5 K6 K5 K6 L1 N Key /S2 S3 E-STOP/safety gate switch Reset button Switch operated Gate open Gate closed -4

Terminal configuration 1 Y36 Y39 Y40 A1 13 23 33 41 57 67 1 power ch. 1 ch. 2 3 Input 9 5 t1 11 8 t2 12 13 23 33 41 57 67 14 24 34 42 58 68 0,6 0,7 0,5 0,8 0,4 1 0,3 1,5 0,2 2 0,1 3 t1[s] 5 4 3 2 6 7 8 10 12 15 1 20 t2[s] S33 Y1 Y2 14 24 34 42 58 68 A2 18 603 Installation Dimensions The safety relay should be installed in a control cabinet with a protection type of at least IP54. Use the notch on the rear of the unit to attach it to a DIN rail. Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing element (e.g. retaining brakket or an end angle). 121 (4.76") 75 (2.95") 87 (3.42") 112,5 (4.41")

Notice This data sheet is only intended for use during configuration. For installation and operation, please refer to the operating instructions supplied with the unit. Service life graph Instantaneous safety contacts: D Nennbetriebstrom (A) GB Nominal operating current (A) F Courant coupé (A) E Corriente nominal de servicio (A) I Corrente di esercizio nominale (A) NL Nominale bedrijfsstroom (A) 10 1 AC1: 230 V DC13: 24 V AC15: 230 V DC1: 24 V AC1: 400 V 0.1 10 100 1000 10000 D Schaltspielzahl x 10 3 E Número de ciclos x 10 3 GB Cycles x 10 3 I Numero dei cicli di commutazione x 10 3 F Nombre de manœuvres x 10 3 NL Aantal schakelingen x 10 3 Delayed safety contacts: D Nennbetriebstrom (A) GB Nominal operating current (A) F Courant coupé (A) E Corriente nominal de servicio (A) I Corrente di esercizio nominale (A) NL Nominale bedrijfsstroom (A) 10 1 DC13: 24 V AC15: 230 V DC1: 24 V AC1: 230 V 0.1 10 100 1000 10000 D Schaltspielzahl x 10 3 GB Cycles x 10 3 F Nombre de manœuvres x 10 3 E Número de ciclos x 10 3 I Numero dei cicli di commutazione x 10 3 NL Aantal schakelingen x 10 3 Technical details Electrical data Supply voltage Supply voltage U B DC 24 V Voltage tolerance -15 %/+10 % Power consumption at U B DC 6.5 W Residual ripple DC 160 % Voltage and current at Input circuit DC: 24.0 V 35.0 ma Reset circuit DC: 24.0 V 100.0 ma Feedback loop DC: 24.0 V 100.0 ma Number of output contacts Safety contacts (S) instantaneous: 3 Safety contacts (N/O), delayed: 2 Auxiliary contacts (N/C): 1-6

Electrical data Category of output contacts in accordance with EN 954-1, EN ISO 13849-1 Safety contacts (S) instantaneous: 4 Delay time <30 s 3 Utilisation category in accordance with EN 60947-4-1 Safety contacts: AC1 at 240 V I min : 0.01 A, I max : 8.0 A P max : 2000 VA Safety contacts: AC1 at 400 V I min : 0.01 A, I max : 5.00 A P max : 2000 VA Safety contacts: DC1 at 24 V I min : 0.01 A, I max : 8.0 A P max : 200 W Safety contacts, delayed: AC1 at 240 V I min : 0.01 A, I max : 4.0 A P max : 1000 VA Safety contacts, delayed: DC1 at 24 V I min : 0.01 A, I max : 4.0 A P max : 100 W Auxiliary contacts: AC1 at 240 V I min : 0.01 A, I max : 8.0 A P max : 2000 VA Auxiliary contacts: DC1 at 24 V I min : 0.01 A, I max : 8.0 A P max : 200 W Utilisation category in accordance with EN 60947-5-1 Safety contacts: AC15 at 230 V I max : 5.0 A Safety contacts: DC13 at 24 V (6 cycles/min) I max : 7.0 A Safety contacts, delayed: AC15 at 230 V I max : 4.0 A Safety contacts, delayed: DC13 at 24 V (6 cycles/min) I max : 4.0 A Auxiliary contacts: AC15 at 230 V I max : 5.0 A Safety contacts, delayed: DC13 at 24 V (6 cycles/min) I max : 7.0 A Contact material AgSnO2 + 0.2 µm Au External contact fuse protection (I K = 1 ka) to EN 60947-5-1 Blow-out fuse, quick Safety contacts: 10 A Safety contacts, delayed: Auxiliary contacts: 10 A Blow-out fuse, slow Safety contacts: Safety contacts, delayed: 4 A Auxiliary contacts: Circuit breaker 24 VAC/DC, characteristic B/C Safety contacts: Safety contacts, delayed: 4 A Auxiliary contacts: Max. overall cable resistance R lmax input circuits, reset circuits single-channel at U B DC 60 Ohm dual-channel without detect. of shorts across contacts at U B DC 120 Ohm dual-channel with detect. of shorts across contacts at U B DC 5 Ohm Times Switch-on delay with automatic reset typ. 200 ms with automatic reset max. 300 ms with automatic reset after power on typ. 200 ms with automatic reset after power on max. 300 ms with manual reset typ. 200 ms with manual reset max. 300 ms

Times Delay-on de-energisation with E-STOP typ. 15 ms with E-STOP max. 30 ms with power failure typ. 30 ms with power failure max. 40 ms Recovery time at max. switching frequency 1/s after E-STOP 50 ms +tv after power failure 100 ms Delay time t V : selectable 0,10 s; 0,20 s; 0,30 s; 0,40 s; 0,50 s; 0,60 s; 0,70 s; 0,80 s; 1,00 s; 1,50 s; 2,00 s; 3,00 s Order no.: 774013 1.00 s, 2.00 s, 3.00 s, 4.00 s, 5.00 s, 6.00 s, 7.00 s, 8.00 s, 10.00 s, 12.00 s, 15.00 s, 20.00 s Repetition accuracy 2 % Time accuracy -15 %/+15 % +50 ms Simultaneity, channel 1 and 2 150 ms Supply interruption before de-energisation 20 ms Environmental data EMC EN 60947-5-1, EN 61000-6-2 Vibration to EN 60068-2-6 Frequency 10-55 Hz Amplitude 0.35 mm Climatic suitability EN 60068-2-78 Airgap creepage in accordance with EN 60947-1 Pollution degree 2 Rated insulation voltage 400 V Rated impulse withstand voltage 4.0 kv Ambient temperature -10-55 C Storage temperature -40-85 C Protection type Mounting (e.g. cabinet) IP54 Housing IP40 Terminals IP20 Mechanical data Housing material Housing PPO UL 94 V0 Front ABS UL 94 V0 Cross section of external conductors with screw terminals 1 core flexible 0.20-4.00 mm², 24-10 AWG 2 core, same cross section, flexible: with crimp connectors, without insulating sleeve 0.20-2.50 mm², 24-14 AWG without crimp connectors or with TWIN crimp connectors 0.20-2.50 mm², 24-14 AWG Torque setting with screw terminals 0.60 Nm Dimensions Height 87.0 mm Width 112.5 mm Depth 121.0 mm Weight 600 g The standards current on 2008-07 apply. -8

Conventional thermal current I th (A) at U B DC 1 contact 8.00 A 2 contacts 6.80 A 3 contacts 5.50 A 4 contacts 5.00 A 5 contacts 4.50 A Order reference Type Features Terminals Order no. 24 VDC Screw terminals 774 013