How do I... If you manage a datacenter, we have a solution for you. Sentry : Cabinet Power Distribution Unit Product Family : Metered CDU.

Similar documents
CS-24VD-L30MA (Master) Key Features. CL-24VD-L30MA (Link)

CS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link)

The -3Ph extension on a product indicates a 3 Phase power product.

CS-10H0A413H3 (Master) Key Features. CL-10H0A413H3 (Link)

Innovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s

Sentry Metered, Smart, and Switched High Density 30 Receptacle 208VAC, 3-Phase 30A Products

How do I... If you manage a datacenter, we have a solution for you.

Power Distribution. For technical support call Online catalog available at leviton.com 461

User Manual. Per Port Monitoring Models

Polar PDUs POWER MANAGEMENT

Tripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3.

Tripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3.

CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. Available in Basic, Metered, and Smart PDU models.

Server Technology Inc.

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

Switched XPDU. 15A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Using Server Technology Sentry Remote Power Managers with Avocent DSView 3 Management Software

Power Distribution Units for Data Centers

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 4

25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC A Red 415V, 0U, TAA

Power Distribution Units for Data Centers

Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity

Power Monitoring (RCX)

5.8kW Single-Phase Switched PDU, 208/240V Outlets (8 C13 & 6 C19), L6-30P, 15ft Cord, 2U Rack-Mount, TAA

30 Amp PanView iq TM (PViQ TM ) Switched with Per Outlet Monitoring and Environmental Power Outlet Units. specifications. technical information

30, 50, and 60 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units

20 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units

APC APPLICATION NOTE #74

16 and 32 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units

Solutions Guide for Cisco UCS B and C Series Servers

Intelligent PDUs. Best in Class Outlet Density Optimal Form Factors Superior Reliability

16 and 32 Amp PanView iq TM (PViQ TM ) Switched with Per Outlet Monitoring and Environmental Power Outlet Units. specifications. technical information

Introducing Server Technology s PRO1 Rack Power Distribution Unit

16 and 32 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units

All power outlet units include 10' power cords, mounting brackets, screws, unit packaging:

PDU Solutions. PDU Solutions

Power Control and Distribution

Rack Power Distribution. Rack power distribution offerings for entry-level networking equipment and high-density server and blade environments

C2W36CE-DQME2M99 (Master) C2X36CE-DQME2M99 (Expansion) Key Features

IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide

G5 PDU Installation Guide

Initial configuration requirements 7. Overview 7 InfraStruXure Manager Setup Wizard 8

Managed Rack PDU MPH2 More efficient Simpler Better

PE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU

ECO PDU Power Distribution Unit

PE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU. 8 outlets. 20A (UL derated 16A) / 16A. Outlet Power Measurement

PDU Inspired by Your Data Center. W IEC PDU Series

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

Remote Management of Data Center White Space: What to Manage and How? Ashish Moondra Sr. Product Manager Chatsworth Products

APC Next Generation Rack ATS

Frequently Asked Questions

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch

THE OFFICIAL TRADE JOURNAL OF BICSI

Models. Specifications

PN5212/PN5320/PN7212/PN7320

Intelligent Power Distribution

SmartOnline 120V 1.5kVA 1.2kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, Pre-installed WEBCARDLX Network Interface, USB, DB9 Serial

PDU - Overview / Non-Intelligent PDU s

Fail-Safe Power Redundancy

Model# ANI SWH. Ver. 1.1

Product brochure. Eaton epdu G3. Simplify installation. Enhance operation. Maximize control.

Table of Contents. 1. Introduction Package Contents Function Installation Web Interface... 5

Intelligent Power Distribution

Product Brochure. Eaton epdu G3 Managed

PDU. InfraPower POWER AUSTI AUSTIN AUSTIN AUSTIN 3 PHASE WSI WI WS W MD BASIC. Enclosure Power Management Solutions

OPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES

SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

MODEL NUMBER: B IP4

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, Pre-installed WEBCARDLX Network Interface, USB, DB9 Serial

Intelligent-Remote Monitoring (3) Environmental Port (4) Power Outlet Level (5)

Excel Power Distribution

SmartPro 1kVA 800W Line Interactive Sine Wave UPS, SNMPWEBCARD option, 1U Rackmount, USB, RS232, EPO, 120V

Modular, scalable, high-efficiency power protection for data centers

Specification Sheet: HT SERIES

SmartOnline V 3kVA 2.7kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 2U Rack, LCD display, USB, DB9 Serial

SmartOnline 208/120V or 240/120V 16kVA 11.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U Rack/Tower, USB, DB9 Serial

Instruction Manual Basic Rack PDU VP7541 and VP9571A

Retired. Full Rack Vertical PDU Model (Ideal for 36U to 47U racks)

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

PHASE ONE Series 700: Uninterruptible Power Supply (UPS) Systems

MODEL NUMBER: B IP2

Intelligent Power Distribution

Symmetra PX 48kW. Scalable from 16 to 48kW. Make the most of your energy TM. Modular, Scalable, High-Efficiency Power Protection for Data Centers

Switched Rack Power Distribution Unit

Engineering and Manufacturing Excellence in Data Centre Infrastructure

Configurable power distribution

ipdu Pocket Guide INTERNATIONAL

Rack PDU Marketing Playbook

MODEL NUMBER: B IP2-K

Auto-Transfer Rack Power Distribution Unit

Deploying High Power to IT Equipment Racks

ipdu Pocket Guide NORTH AMERICA

Features and Benefits: Power IQ DCIM Monitoring Solutions

Server Technology, Inc.

Liebert GXT3 5kVA-10kVA UPS Compact UPS Systems For High Power Network Rack Applications. AC Power For Business-Critical Continuity

Who Needs Remote Power Management for Power Distribution, Power Measurement and Power Control of 48 VDC Equipment?

Transcription:

If you manage a datacenter, we have a solution for you. How do I... Distribute power to all the equipment in the cabinet? Distribute and load balance 3-phase power? Monitor True RMS input current? Reboot remote servers and network devices? Know when the cabinet temperature is too high? Provide adequate power distribution for blade servers? Sentry : Cabinet Power Distribution Unit Product Family : Metered CDU Cabinet Power Distribution with Local Input Current Monitoring and Branch Circuit Protection. Smart CDU Power Distribution with the expanded functionality of SNMP-based Input Current Monitoring and Temperature and Humidity monitoring. Switched CDU Flagship CDU with remote monitoring and management, including reboot commands to connected servers and network equipment.

Sentry : CDU Product Family Sentry : CDU Anatomy The complexity of IT equipment in today s data centers and remote branch office locations requires new solutions for building a solid infrastructure. It must support 24/7 operations and reduce the instance of locked-up or failing equipment leading to network downtime; Five nine s availability 99.999% uptime demands it. Blade servers and high density computing power requirements continue to increase, creating heat proliferation and more challenges for managing the IT environment. To maintain their competitive advantage, data center managers need SNMP-based solutions that monitor, track and manage servers and IT equipment and the equipment cabinet infrastructure that houses them. The photo below illustrates where each of the CDU s key features are located: Serial access for RS-232 and local communications. Integrated Power Metering Displays per branch circuit or phase. Integrated support for Temperature and Humidity probes. IP-enabled for Secure Web, SSH & SNMP management UL 60950-1 Branch Circuit protection with UL listed fuses. The Sentry CDU Family delivers these solutions with three distinct product lines: Metered CDU Cabinet Power Distribution with Local Input Current Monitoring and Branch Circuit Protection. Smart CDU Power Distribution with the expanded functionality of SNMP-based Input Current Monitoring and Temperature/Humidity monitoring. Switched CDU Completes the solution by adding Full Remote Monitoring & Management, including reboot commands to connected servers and network equipment. CDU Product Family Solutions for the Data Center Equipment Cabinet 120V or 208V output for up to 84 output receptacles. Center rail notch for flush mounting in cabinet. Single-phase or three-phase power input for up to 20kW.

Sentry : Metered CDU Power Distribution with Input Current Monitor LED Zero-U Vertical Enclosures C-12V1 C-12V2 C-21V C-24V C-24VD1 C-24VD2 C-24V1 C-24V2 C-48VD1 C-48VD2 20A 18U (31.25in) 18U (31.25in) 26U (45in) 18U (31.25in) 18U (31.25in) 31U (54in) 31U (54in) 31U (54in) 31U (54in)

Metered CDU : Key Features The Sentry Metered CDU products provide reliable power distribution for all the devices in your equipment cabinet, from 5,000 to 20,000 Watts per cabinet. Single-phase 110-120V or power distribution with options -or- 3-Phase ; 20A or 30A power distribution options. Local input current monitoring allows the installation engineer to verify the aggregate load on the circuit or phase. Branch Circuit Protection The Sentry CDU Family meets the new UL 60950-1 requirement for branch circuit protection. Attention! The Sentry CDU products meet the UL 60950-1 criteria by providing overcurrent protection with UL listed Bussman SC fuses for each branch circuit. Input Current Monitoring The CDU s exclusive True RMS current monitoring is critical to preventing overloads in high-density computing environments. LED digital displays on the CDU enclosure report the input current of each phase or branch circuit. Button Mounting All CDUs are also compatible with button mounting. Several cabinet manufacturers are now using this method for installing power distribution units in the cabinet. Equipment Cabinet Power Demands on the Rise From 2001-2007, data center equipment cabinet power requirements increased by over 1000%. That equates to an average annual power increase of over 3000 Watts annually. Is your power distribution system up to the challenge? Sentry : Metered CDU Power Distribution with Input Current Monitor LED Blade Server Horizontal CDUs 20kW C-4H (1U; 10in Depth) C-12HD (2U; 10in Depth) KILOWATTS/CABINET 8kW Horizontal CDUs 5kW 2kW C-10H1 (1U; 10in Depth) C-12H2 (1U; 10in Depth) 2001 2003 2005 2007 TIMELINE

Sentry : Smart CDU Power Distribution with LEDs, IP-based Power, Environmental Monitoring Zero-U Vertical Enclosures CS-12VY(D) CS-21V CS-24V CS-24V2 CS-48VD1 CS-48VD2 CS-48VD3 CS-54VD CS-84VD, 208 240V 3-Phase 60A 27U (46.5in) 20A 26U (45in) 38U (66in) 38U (66in)

Smart CDU : Key Features The Smart CDU products provide reliable power distribution combined with remote power and environmental monitoring. Use the network interface to view power, temperature and humidity levels via Web browser, or receive SNMP-based alarms when conditions exceed defined thresholds. Trends Impacting Data Center Power Distribution > More high-density, multiple units filling racks and cabinets. > More systems with higher and increasing power density. > More use of higher rated supplies to reduce cabling costs. > More use of intelligent power and metering. > More 3-Phase applications and increased use of metering to insure load balanced phases in such systems. > More systems with higher nominal input voltage ratings (208V vs. traditional 120V). > More individual power distribution units being provided with an increasing number of outlets. > More global power distribution equipment being developed at 20A and 30A. > More use of IEC 60320 outlets, especially for a global product with 208V nominal supply ratings. (Source: IEEE) CS-12HD2 (2U;10in Depth) Branch Circuit Protection IP Blade Server Horizontal CDUs Input Current Monitoring Button Mounting Input Current Monitoring The Smart CDU and Switched CDU also provide IP-access to Input Current Monitoring. Receive SNMP-based alerts when power draws exceed defined thresholds. Temperature & Humidity Monitoring The Smart CDU and Switched CDU support two external probes. Each of these probes measure both temperature and humidity. Receive SNMP-based alert notifications when conditions exceed defined thresholds. Enterprise View PDU Management Enterprise View uses auto discovery to locate all CDUs from one location and provides a graphical interface for each unit. Monitor temperature and humidity levels at each site; receive notification of critical conditions when input current or environmental conditions are outside defined thresholds. Center Rail Notch An exclusive design feature allows the CDU to be mounted flush inside the cabinet, over the center rail commonly found in HP, Dell and other popular cabinets. (Only available on the CS-54 and the CS-84 vertical units.) Sentry : Smart CDU Power Distribution with LEDs, IP-based Power, Environmental Monitoring CS-12HD3 (2U; 10in Depth) 3-Phase

Sentry : Switched CDU Solutions for Remote Access, Rebooting, and Power Cycling of any attached device, anywhere in the world. Zero-U Vertical Enclosures CW-16V1 CW-16V2 CW-24V2 CW-24V3 CW-32VD1 CW-32VD2 CW-48VY 27U (45.75in) 27U (45.75in) 40U (69in) 40U (69in) 29U (50in) 29U (50in) 30A 40U (69in)

Switched CDU : Key Features The Switched CDU products provide complete lights-out management of a data center or remote branch office. The Switched CDU s combine remote configuration and management with power distribution and power and environmental monitoring. Reboot a single or dual-power server with one command. Receive SNMP alerts when power or environmental conditions exceed thresholds. Assign users specific access rights to designated outlets or groups. Only the Switched CDU products provide the flexibility needed for all data centers and remote sites, including power requirements for high-amp, high voltage; UL 60950-1 branch circuit protection; SSL& SSH security; and SNMP-based input current monitoring. Switched CDU : Expansion Module The Expansion Module CDU CX is our exclusive method for linking outlets on different power circuits together. A CX links to any Switched CDU, increasing the number of managed outlets on a single IP address. Control individual outlets on either the Switched CDU or CX, or control grouped outlets between the Switched CDU and CX with one command. IP Input Current Monitoring Branch Circuit Protection Temperature and Humidity Monitoring Button Mounting Enterprise View PDU Management Remote Management Point. Click. Reboot. Reboot a locked-up server from a remote location. The Switched CDU s firmware interface provides complete configuration and control of the unit from a remote location via Web, SNMP or serial access. Create user accounts and assign access rights. Simultaneous user access makes the Switched CDU an ideal solution for co-lo sites where both host and remote user need access to reboot servers. Create groups of associated outlets and reboot a dual-power server with one point and click. Security and communications features include SSL, SSH, MD5, TACACS, and LDAP. Power-up Sequencing of outlets and High-amp in-rush protection ensures safe boot-up of all your equipment. Each CX links to a Switched CDU, which contains both network and serial interfaces. When linked to a Switched CDU, the CX s outlets are auto-discovered by the Switched CDU s firmware, and all available outlets CW CX are viewable and CW-2H1 (1U; 4.75 Depth) CW-8H1 (1U; 10in Depth) controllable through the firmware. Each Expansion Module CDU can be a single-power feed horizontal enclosure or a single or dualpower feed zero-u enclosure. Sentry : Switched CDU Solutions for Remote Access, Rebooting, and Power Cycling of any attached device, anywhere in the world. Horizontal CDUs 20A CW-2H2 (1U; 4.75 Depth) 20A CW-8H2 (1U; 10in Depth)

Sentry : Enterprise View PDU Manager Web-based Enterprise-level PDU Management Enterprise View : Key Features > Accessible from Standard HTML Web Browser > Auto-Discovers your Sentry devices on an existing network > Build logical and functional views of Sentry units in geographically dispersed Data Centers > Supports Equipment with Single or Redundant Power Supplies > Obtain key information regarding input current monitoring, temperature & humidity from Sentry units in multiple remote sites > Access Remote Power Management functionality to cycle power and reboot selected servers > Provides detailed event logs for each device for up to one year > Design a custom report of events and activity for selected Sentry device(s) > Does not require additional seat-licenses > Does not require additional server hardware to host Manage Multiple Networked CDUs from One Location Enterprise View PDU Management is a network management system capable of managing CDUs in IP-based enterprise networks. Enterprise View PDU Management makes it easier to maintain total control over Networked Smart and Switched CDUs. From one location, Enterprise View uses auto discovery to locate all the CDUs and provides a graphical interface to all functionality of each individual CDU. This also enables the site administrator to perform a reboot command to any one outlet, monitor the temperature and humidity levels in each site, and be notified of critical conditions when input current or environmental conditions escalate. D istributed by: Mega Hertz 80 0-883-8839 s ales@megahz.com ww w.megahz.com Server Technology, Inc. 02/06/06 version. Sentry is a trademark of Server Technology, Inc. Printed in USA.