Gallagher GBUS Devices

Similar documents
CardaxFT Reader I/O Interface

The Cardax FT Controller 6000 can support up to 16 GBUS devices.

4 balanced inputs 1 relay output

Controller 3000, dependent on reader technology and site configuration. All I/O functionality is provided on the Controller 3000.

Controller Cardax FT Controller The CardaxFT Controller 5000 is the intelligent field controller in the CardaxFT security system.

to that area and whether or not the Cardax FT GBUS URI (Standard or person holds these competencies. Wiegand variant)

Access Control Product Overview

Cardax FT XtraSec. System Catalogue ELM

Cardax Prox Plus Mifare Reader

Cardax FT Connectivity Guide

Aged Care Security Solutions. security.gallagher.com

Gallagher Airport Security Solutions. aviation sites around the world trust security management solutions from gallagher

Cardax FT Command Centre

Gallagher Controller 6000 PoE + Kit

Cardax FT Command Centre is the central management tool for the Cardax FT system. The software is powerful, and caters for a versatile feature set.

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

Cardax FT Controller 3000

Cardax FT Series 3 Command Centre

PRO3200 Professional Modular Access Control Hardware

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

PRO2200 Professional Modular Access Control Hardware

Connecting a Cisco Input Module

Broadcast Notification solutions

Simple & Easy Installation

6222 Two Door Module Technical Operations Manual

Suprex RS-485 SPX-7500 Wired Reader-Extender

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

using optional EMX 190 expansion modules), and makes access decisions based on its own distributed

AC-215x-B Series 2-Reader Networked Access Control Panel Hardware Installation and User Manual. Models: AC-215-Bx AC-215-DIN AC-215IP-Bx AC-215IP-DIN

Compact Coded Magnetic Safety Interlock Switch and Control Units

TAC I/NETTM 1284, 1280, Security Control Unit

SPX-7400_SPX-7410_MAN_161028

Eaton DC Power Solutions

AN-013 LED and Beeper Control With 4 Wire Wiegand Reader

Quick Start Installation Guide

genesis TECHNICAL MANUAL Two-Door Controller GEN-045

PRT-PX16 16 PGM Output Expander

TS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual

PRT-RDS2 Standard 2 Reader Expander

Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL

TruPortal Dual Door Interface Module Quick Reference

Two Door Controller GEN-045

Gallagher T20 Reader. Installation Note. The Gallagher T20 Reader

TruPortal Output Expansion Board Quick Reference

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

Protégé Elite Suite Touch Screen Keypad (PRT-TLCD)

PW6000 Modular Access Control System PW6000 Intelligent Controllers and Modules

SINGLE READER EXPANSION MODULE

TB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.

Serial Data DIN Fiber Link System

AC-225x-B Series. Expandable 2-Reader Networked Access Control Panel Hardware Installation Manual. Models:

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502

genesis genesis Expander Unit - Technical Manual TECHNICAL MANUAL Australian Owned, Designed and Manufactured Expander Unit GEN-010

Product Manual. TZ Centurion Port Links. TZ Centurion Port Link 7101CL TZ Centurion Multi Port Link 7105CL

HI SEC Integrated Systems

GV-AS200 Controller. Hardware Installation Guide

Viconics VT76x6W Water-source Heat Pump Controllers Engineering Guide Specification

Gallagher T12 Reader. Installa on Note. The Gallagher T12 Reader

VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide

Online data sheet. FW101 Ex SCATTERED LIGHT DUST MEASURING DEVICES

VICON ACCESS CONTROL CONTROLLERS

FlexPass. ASR Long Range Reader. Installation Guide Jeronimo Road Irvine, CA July 16, 2007 Document Number K , Rev B

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

APPLICATION GUIDE. Interface Modules IM Series.

Connecting a Cisco Output Module

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

CYPRESS " " EXP SPX Expansion interface! modules EXP-2000_MAN_0314

Suprex RF Series CYPRESS. Operations Manual. Suprex Reader Extender - RF Wireless Interface EXP SPX Mhz SPX-5521_MAN_0316

VZ7000 Series. BACnet Commercial Zoning System

S-series Mass Connection Solutions

Web-based Access Control System. Employee access. EMBEDDED Web Browser

Camden - Key Switches

DeltaV Bulk Power Supplies

VRP5045W1045W 24 VAC Powered ZigBee Repeater For Schneider-Electric Wireless Networks Applications

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

Gallagher Critical Infrastructure Solutions

Connecting a Cisco Reader Module

NETWORK CONCENTRATOR LINK. This equipment must only be installed and serviced by professional qualified personnel.

INSTALLATION GUIDE DM-20 English Version 1.10 EN DM20 V1.10A

IPassan Installation guide

ACX Series. Access Controller for Ethernet

KT-300 DOOR CONTROLLER INSTALLATION MANUAL DN KANTECH SYSTEMS INC.

RS-422/485 to Fiber Industrial Converter

PIB300 and PIB301 User Guide. Installation and operation instructions for Panel Interface Board

FUSION COMPACT. Load a. Line A. Inverse parallel scrs. Line B. Line c. inverse parallel scrs. Load C SCR POWER. O delta CONTROLLERS

ENCRYPTED HIGH SECURITY

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection

EMS10 - EMS50. Cameo specification sheet. Product Description

January 2013 PRICE SCHEDULE A 2.0. Access Plus Telephone Entry & Access Control

Key Switch. Document version: 1.5 (Updated 02 May 2017)

TALON Network Manager- 2 & 6 Express

Agilent 66000A 1200 W DC Modular Power System, GPIB

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

April 2015 PRICE SCHEDULE A 2.0 Stand-Alone Access Control

Installation Guide. Avigilon ACM Embedded Controller

MR51e Reader Interface

Quick Start Installation Guide

Transcription:

Gallagher GBUS Devices Gallagher GBUS I/O Devices provide flexible, cost effective input and output expansion options with an option to connect readers. Gallagher GBUS I/O Devices include the: Gallagher 8-Input Expansion Interface Gallagher I/O Expansion Interface Gallagher High Density I/O Interface Gallagher GBUS Universal Reader Interface They connect to Gallagher Controllers via asynchronous RS485 Cardax IV proprietary GBUS protocol. Controlling Inputs and Outputs Making no high level decisions, the GBUS I/O devices monitor the state of their balanced inputs and switch the output relays as instructed by their Controller. Monitoring Inputs The inputs on Gallagher GBUS I/O devices are 4-state balanced inputs. The four states monitored are: Open Closed Short Circuit (Tamper) Open Circuit (Tamper). Inputs may be used for: Access controlled doors Passive Infra-Red detectors (PIRs) Uncontrolled doors Equipment alarms Any other devices that provide a clean contact. Outputs Relays may be used as: Door control Alarm outputs e.g. to activate sirens Logic activated outputs e.g. to switch on air conditioning Time activated outputs e.g. to switch on lighting. Integrating Readers The Gallagher GBUS Universal Reader Interface provides connections for readers: Using 4-core cable, up to 2 Cardax IV format readers Using 6-core cable, up to 1 Wiegand format reader. Data Protection All communications between the Gallagher Controller and its connected Gallagher GBUS I/O Devices are encrypted and check summed to protect data from manipulation during transmission. security.gallagher.com

Gallagher GBUS Universal Reader Interface The Gallagher GBUS Universal Reader Interface is designed to provide an interface for up to 2 doors to the Gallagher system. Ideal for retrofits, the Gallagher GBUS Universal Reader Interface, when configured in conjunction with a Gallagher Controller, will deliver a cost effective solution for sites using daisy-chained door wiring. Gallagher GBUS Universal Reader Interface Wiegand Variant The Gallagher GBUS Universal Reader Interface Wiegand variant is a 2 Wiegand reader variant. It provides connections for 2 Wiegand readers only and 4 inputs and 2 outputs. Its small design size and plastic enclosure allow cavity wall mounting, installation in a flush box or installation in the Gallagher GBUS I/O Accessory Cabinet. Connectivity diagrams Cardax IV format entry and exit readers connected to the Gallagher GBUS Universal Reader Interface for the access control of one door. Two Cardax IV format entry readers (with push button exits) connected to the Gallagher GBUS Universal Reader Interface for the access control of two doors. One Wiegand format reader connected to the Gallagher GBUS Universal Reader Interface for the access control of one door.

Gallagher I/O Expansion Interface The Gallagher I/O Expansion Interface is an input monitoring and output control panel and is normally used for intruder alarms, however it can also provide I/O for up to 2 doors. Gallagher I/O Expansion Interface The Gallagher 8-Input Expansion Interface is an input monitoring panel and is normally used as an input panel for intruder alarms. Connectivity diagrams

Gallagher High Density I/O Interface The Gallagher High Density I/O Interface is an input monitoring and output control panel and is normally used for intruder alarms, however it can also provide I/O for up to 4 doors. The Gallagher High Density I/O Interface includes onboard tamper protection. Variable End of Line Resistance Variable end of line resistance is supported for all Gallagher GBUS I/O Devices and the Gallagher Controllers. Gallagher Cabinets Two Gallagher Cabinets are available to accommodate the Gallagher Controllers and the Gallagher GBUS I/O Devices: Gallagher Cabinet Gallagher Dual Cabinet The Gallagher Dual Cabinet is available with or without a power supply. Refer to the Gallagher Cabinets data sheet for further information. Connectivity diagrams

Gallagher GBUS Devices Configuration Table DEVICES Input Output Cardax IV Reader Wiegand Reader Proportion of One GBUS Universal Reader Interface 8 2 2 1 ¼ GBUS Universal Reader Interface Wiegand variant 4 2 0 2 ¼ 8-Input Expansion Interface I/O Expansion Interface High Density I/O Interface footprint 8 - - - ¼ 8 4 - - ½ 16 16 - - 1 It is possible to install 2 Gallagher High Density I/O interfaces in a single cabinet footprint by mounting one on top of the other. The Gallagher GBUS I/O Accessory Cabinet accommodates 1 footprint while the Gallagher Dual Cabinet accommodates 2 footprints.

GBUS I/O DEVICES Standard specifications applicable to all devices JANUARY 2013 Power Supply Voltage 13.6 v DC±15% Inputs / Outputs 4-State balanced inputs Default using dual 4k7 Ω termination resistors - configurable Relay Outputs Dry contact relays (c/o contacts) Relay Specifications Resistive load 3 amps at 24V DC/AC Inductive load 1 amp at 24V DC/AC Communications Between Gallagher Controller and GBUS I/O Devices RS485 at 38.4 Kbits per second Wiring format - data 2 wire (using Cat5) Wiring format - power 2 wire (gauge selected to suit cable length) Cable Specifications Gallagher GBUS to Gallagher Controller 1200m max Gallagher Readers 4 wire, 200m max Wiegand Readers 6 wire (see manufacturer s specifications for max. cable length) GBUS I/O DEVICES Standard specifications applicable to individual units Gallagher 8-Input Expansion 4-State balanced inputs 8 Power supply current 45 ma Shipping weight (nominal) 175 gm Proportion of cabinet footprint ¼ Gallagher 8-Input Expansion 4-State balanced inputs 8 Relay outputs 4 Power supply current (without relays operated) 45 ma Power supply current (all relays operated) 175 ma Shipping weight (nominal) 250 gm Proportion of cabinet footprint ½ Gallagher High Density I/O 4-State balanced inputs 16 Expansion Relay outputs 16 Power supply current (without relays operated) 85 ma Power supply current (all relays operated) 650 ma Shipping weight (nominal) 500 gm Proportion of cabinet footprint 1 Gallagher Universal Reader Interface Standard Wiegand Cardax format reader connections 2 n/a 3rd party (Wiegand format) reader connections 1 2 4-State balanced inputs 8 4 Dry contact relays (c/o contacts) 2 2 Power supply current (without relays operated) 40 ma 40 ma Power supply current (all relays operated) 100 ma 100 ma Shipping weight (nominal) 250 gm 250 gm Proportion of cabinet footprint ¼ ¼ Compliance Standards All equipment complies with CE, C-Tick and FCC approvals. Please contact Gallagher for the latest list of approvals. In order to comply with international standards, all Gallagher units must be installed in Gallagher Cabinets following the directions in the installation instructions.

GALLAGHER WORLD HEADQUARTERS Kahikatea Drive, Hamilton 3206 Private Bag 3026, Hamilton 3240 New Zealand TEL: +64 7 838 9800 EMAIL: sales@security.gallagher.com REGIONAL OFFICES New Zealand... +64 7 838 9800 Americas... +1 877 560 6308 Asia... +852 3468 5175 Australia... +61 3 9308 7722 India... +91 80 2661 1590 Middle East...+9615 808728 South Africa... +27 11 974 4740 United Kingdom / Europe... +44 2476 64 1234 Disclaimer: System configuration, network capacities and the volume of system activity affect performance. Please contact Gallagher for advice. In accordance with the Gallagher policy of continuing development, design and specifications are subject to change without notice. Gallagher Group Limited is an ISO 9001:2008 Certified Supplier. Copyright Gallagher Group Limited 2012. All rights reserved. 3E1335-04/15 security.gallagher.com