Electronic monitoring relays PMDsrange

Similar documents
E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

E-STOP relays, safety gate monitors

Safe monitoring relays

E-STOP relay, safety gate monitor

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Faults on the system Proximity switch connection technology:

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relay, safety gate monitor

E-STOP relays, safety gate monitors

Two-hand control unit

Can be configured in the PNOZmulti Configurator Semiconductor outputs: or 4 safety outputs in accordance with EN 954-1, Cat. 3

Two-hand control unit

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Safe monitoring relays

E-STOP relays, safety gate monitors

Two-hand control unit

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

E-STOP relay, safety gate monitor

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Contact expander modules

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Safe timer relay/contact expansion modules

Safety relays PNOZsigma

Safe timer relay/contact expansion modules

ISOMETER isoev425 with coupling device AGH420

ISOMETER isopv with coupling device AGH-PV

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Datasheet - SRB 402EM-24V

PNOZ s1. Safety relays. Operating Manual EN-07

ISOMETER isoev425/isoev425hc with coupling device AGH420

T M. IRDH375 Series. Digital Ground Fault Monitor / Ground Detector For Ungrounded (Floating) AC/DC Systems. Technical Bulletin NAE / 09.

02/11/2015

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

Zelio Control-modular measurement and control relays 1

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

20 inputs for connecting, for example:

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Datasheet - SRB 301LC/B-24V

PNOZ s9. Safety relays. Operating Manual EN-08

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

PNOZ s2. Safety relays. Operating Manual EN-07

H3CR-F H3CR-F8 H3CR-F-300 H3CR-F8-300

Products. Base units PNOZmulti Base units PNOZmulti PNOZ m0p (ETH) PNOZ m1p (ETH) PNOZ m2p (ETH) PNOZ m3p (ETH) 2.

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

Model Number Structure

LED unit. Selection diagram LED COLOUR white LED red LED green LED blue LED orange LED INDICATION MODE CONNECTIONS MOUNTING TYPE

02/11/2015

4 C/O. Contact material AgNi AgNi gold-plated Nominal contact current Inrush current

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Displays Transducers. Displays and transducers

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

Power supply module, bus connection module

Magnetically Actuated Safety Interlock Switches

Datasheet SRB301ST 24V (V.2)

TSXPAY262 Preventa safety module - 24 V DC - standard format - < 5 W

EM2020 Selectable AC transducer A (UK)

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

Safety Relay Unit (I/O Unit Type)

RM35TF V AC

RM35LM33MW liquid level control relay RM35-L V AC/DC

ISOMETER iso685-d-b. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Preliminary data sheet

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

Model Number Structure

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

RM35LM33MW liquid level control relay RM35-L V AC/DC

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

Contact protection relay

Classification Enclosure rating Input voltage Type of

MIC-2 MKII, Multi-instrument DATA SHEET

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

Transcription:

Unit features Altdaten CMT For DC and AC supplies Normally energised mode Fault latching or automatic reset Normal/test mode External reset button can be connected Description The insulation monitoring relay is enclosed in an S-95, slimline housing. 2 versions are available, with measuring ranges of 50 kω and 200 kω. Its universal power supply operates with all supply voltages. Features: Relay outputs: 1 auxiliary contact (C/O) Two insulation measuring circuits Detects symmetrical insulation faults Switch for function testing LED for supply voltage and fault The unit measures the insulation resistance between the phases and the operating earth on galvanically isolated voltage supplies. If the insulation resistance in either of the two measuring circuits drops below the response value R on, the auxiliary contact switches and the Fault LED is lit. If the release value R off is then exceeded, the device is ready for operation immediately if automatic reset is selected; if manual reset is selected, it is necessary to operate an external button or the MR/AR switch. Altdaten CMT The insulation monitoring relay provides protection against insulation faults in galvanically isolated voltage supplies (IT systems). It meets the requirements of DIN EN 61557-8. Approvals Zulassungen Internal wiring diagram Reset Y1 12 14 AR: MR: speichernd/nicht speichernd lätching/non latching mémorisation/sans mémorisation acumuladora/no acumuladora con/senza memorizzazione handmatig/automatische reset K1 G Test: Normal: Auswertung Evaluation Èvaluation Evaluatión Valutazione Evaluatie R an 24 V DC AC/DC: 24... 240 V R an A1 A2 B3 11 Key : Mains voltage R on : Response value at B3-A2: 24 VAC/DC at A1-A2: 42-240 VAC/DC

Timing diagram R ab R an 11-14 11-14 1 Reset 0 nicht speichernd non-latching sans mémorisation no acumuladora senza memorizzazione automatische reset speichernd latching mémorisation acumuladora con memorizzazione handmatige reset Key : Supply voltage R on : Response value R off : Release value : Insulation resistance Connection examples Example 1 AC application circuit N 1 A1 Y1 B3 A2-2

Example 2 3AC application circuit L2 L3 1 A1 Y1 B3 A2

Example 3 3AC/DC application circuit L2 L3 1 alternativ/alternatively/ alternatif/alternativo/ in alternativa/alternatief G1 A1 Y1 B3 A2-4

Example 4 DC application example N 1 G1 ~ = A1 Y1 B3 A2

Technical details Electrical data Supply voltage AC/DC: 24... 240 V Tolerance 85... 110 % Frequency range AC 50 60 Hz Power consumption 240 VAC: 5 VA, 24 VDC: 1 W Switching capability in accordance with EN 60947-4-1 AC1: 240 V/0.1... 5 A/1200 VA DC1: 24 V/0.1... 5 A/120 W EN 60947-5-1 AC15: 230 V/2 A; DC13: 24 V/1.5 A Output contacts 1 auxiliary contact (C/O) Contact material AgCdO, 3 µm gold plating for low load range 1-50 V/1-100 ma Contact fuse protection in accordance with Max. 6 A quick or max. 4 A slow EN 60947-5-1 Measuring circuit Rated mains voltage (monitored supply) 50 kω version: AC/DC: 0... 240 V 200 kω version: AC/DC: 0... 400 V Response value 50 kω version: 12.5... 50 kω, selectable 200 kω version: 50... 200 kω, selectable Release value 50 kω version: Response value + ca. 5 kω 200 kω version: Response value + ca. 20 kω Max. measuring current (DC) 50 kω version: 2.4 ma 200 kω version: 1.0 ma Max. measuring voltage (DC) ± 17 V Max. permitted external voltage (AC/DC) 50 kω version: 264 V 200 kω version: 460 V Min. impedance (AC/DC) 50 kω version: 75 KΩ 200 kω version: 300 KΩ Max. permitted line capacitance 1 µf Max. response error in accordance with ± 15% DIN EN 61557-8 Measuring time 10 s Environmental data EMC EN 61000-6-2, EN 61000-6-4 Vibration in accordance with EN 60068-2-6 Frequency: 10... 55 Hz Amplitude: 0.35 mm Climatic suitability EN 60068-2-78 Airgap creepage EN 60947-1 Ambient temperature -10... +55 C Storage temperature -40... +85 C Condensation and ice formation Not permitted Mechanical data Cross section of external conductors 1 core flexible 0.20 4.00 mm², 24 10 AWG 2 core with the same cross section, flexible with crimp connectors, no plastic sleeve 0.20 2.50 mm², 24 14 AWG without crimp connectors or with TWIN crimp connectors 0.20 2.50 mm², 24 14 AWG Torque setting for connection terminals 0.6 Nm (screws) Mounting position Any Housing material Housing PPO UL 94 V0 Front ABS UL 94 V0 Protection types Mounting: IP54 Housing: IP40 Terminals: IP20 Dimensions (H x W x D) 87 x 22.5 x 121 mm Weight 150 g Bestelldaten -6

Order reference Type R on Order no. 24-240 VAC/DC 50 KΩ 884 100 24-240 VAC/DC 200 KΩ 884 110 : Supply voltage R on : Response value