AUTOMATION IN THE LABORATORIES OF DIMEL
|
|
- Wilfred Hudson
- 6 years ago
- Views:
Transcription
1 Simposio de Metrología al 7 de Octubre UTOMTON N THE LORTORES OF DMEL Marcos ntonio Salvino da Silva National nstitute of Metrology, Normalization and ndustrial Quality NMETRO Management of Legal Metrology DMEL Tel: ; Fax: ; masalvino@inmetro.gov.br Summary: This work shows the automation of a calibration process using the program LabView, looking for the improvement of the current procedure of calibration of the Onneken pressure standard. Using the program helps to increase the productivity and efficiency of the laboratories of DMEL, where some steps of the current process have been reduced or eliminated. Key Words: Calibration, Sphygmomanometer, Legal Metrology. 1. NTRODUCTON 3. METHODOLOGY With the growing demand for high quality services and tests of and at reduced costs, the laboratories have reached a very important point of change: how to find solutions that can assure the costs reduction and the process reliability. ctually the organizations are just living this context and they surely affirm that one of the paths that might help to significantly reduce costs and the accuracy of measurement of a instrument is the automation of the processes, by removing mistakes, wastes, reducing time of the calibration, issuing automatically reports or certificates and minimizing costs in general. This work has as objective to discuss the automation of the calibration process of the Onneken pressure standard: possible sources of errors and uncertainties, automation levels among others.. SYMOLOGY p H ob L ob R ob T ob S ob E ob, Seq1 c Seq1d = uncertainty of Hüber standard; = hysteresis of Onneken standard; = resolution of Onneken standard; = reproducibility of Onneken standard; = temperature on Onneken standard; = sensibility of Onneken standard; = error from the Onneken standard; : variance of the 1st sequence in the increasing pressure (c) and decreasing (d); and, Seq c Seqd : variance of the nd sequence in the increasing pressure (c) and decreasing (d) Current procedure of calibration [11] The reference standard can be a quantity with a well-known value or a measurement system with an accuracy much better than that one of the measurement system to be calibrated. The current procedure is based on the indirect method, whose Hüber reference standard attends to the requirements of maximum permissible error and the measurement uncertainty. Figure 1 shows a calibration example represented by the indirect method. The value of the pressure to be applied to the measurement system in each calibration point is adjusted in Onneken standard and read in the Hüber reference standard. The main advantage is that you do not need to evaluate the subdivisions of the scale of Onneken standard and, consequently, reduce or eliminate the contribution of the uncertainty from the operator. Table 1 shows the technical characteristics of both standards. ccording to the reference [6], for class 0.1 manometers, it should be made the calibration in, at least, 10 calibration points in each scale. Manufacturer Onneken Hüber nstrument Model OM S PRF Range of indication 0 a 300mmHg 0 a 400mmHg 1 Scale division 0,mmHg 0,01mmHg Resolution 0,03% VFE 0,01% VFE Tab. 1 Characteristics of the standards. 1
2 Simposio de Metrología al 7 de Octubre 3.. utomated procedure This procedure tries to follow the current one, except that some difficulties have been reduced or eliminated by using technology of programs, increasing the productivity of the laboratory. t can be stated that the automation of the calibration of the Onneken pressure standard is partial, because due to its physical construction it still makes necessary the operator s presence LabView Program Fig. 1 Calibration example for the indirect method. n the practice [10], it has been adopted 13 points of calibration from 0mmHg, with increments of 5mmHg. Two measurement cycles are realized, in each cycle is made a load sequence and, after 5 minutes, one of unload sequence, resulting in 5 points of calibration. Taking into account those data already registered, a Certificate of Calibration is issued with the following parameters informed: Hysteresis; Systematic error maximum; Medium dispersion; and Uncertainty of measurement. n the procedure previously described, the following difficulties or problems were observed: The time spent in the calibration, using only one operator can surely affect the results of some parameters; The initial registration of the data written down in paper, could generate some annotation mistakes; The typing of the data for emission of the certificate or the difficulty of recognition of the operator's calligraphy that realized the calibration, could generate some typing mistakes; The operator's experience in handling the Onneken standard determines the agility of the same; Using two operators can reduce the time of calibration, even it is expensive; and The physical construction of Onneken standard which it does not offer analogical output. The LabView program of National nstruments [3, 4] is a programming language, oriented to graphic objects, devoted to the virtual instrumentation of laboratories, allowing the aid in projects, generating reports in Word and Excel formats, as well as the improvement, development and management of great and complex systems. 1 The LabView Platform is of easy visualization, through graphic resources; it possesses several built-in functions. esides innovator, it substitutes the traditional environment conceived in lines code by icons (subroutines), interlinked for threads, in which each color represents the flow of several types of data (strings, integers, vectors, matrix etc.). n the Figure a routine is presented in LabView and one in the traditional environment. Fig. Comparison between both ambient The control panel of the program shows an interface for Windows, being built easily with graphic tools previously developed as tables, graphs, indicators, controls, leds, etc. The Figure 3 exhibits the interfaces of data input of the two patterns. efore starting the calibration it should be selected the configuration of Hüber standard by means of the controls exhibited in the front panel: time of integration; stability and transmission type. The 1 This is a special range. The nominal range is from 0 to 1,50mmHg. VFE = Final Value of the Scale
3 Simposio de Metrología al 7 de Octubre other controls possess defined values or the program searches to adapt itself. To execute the automation, the full duplex RS3 communication interface has been used with connectors D5 or D9. The program accomplishes an automatic search in the ports of communication COM1 and COM, identifying in which of them the Hüber reference standard is actually connected. n this automated procedure, some improvements have been observed such as the obtaining of a larger number of measurements for a certain calibration point, the automatic fulfillment of the worksheet that it can be visualized by the operator, the automatic generation of the calibration certificate, the exclusion of unstable data, the counting of time with sound warning, the calculation of the measurement uncertainty, besides the other parameters mentioned previously. n the Figure 4, it shows the interfaces of the worksheet and the data output. the stop parameter that is the string correspondent's format, that represents a stable reading supplied by the Hüber reference standard. This string has a format in which the read quantity provided, followed by the unit mmhg. f during the data acquisition there is any instability in the pneumatic circuit, in a calibration point, the routine neglects the current datum Determination of the measurement uncertainty The estimate of the measurement uncertainty of the Onneken pressure standard followed the methodology from the Guide for the Expression of the Uncertainty of Measurement [7]. The measurement uncertainty is the combination of the uncertainties of the type and type, what can be expressed by the mathematical relationship: = + (1) M Fig. 3 nterfaces of data input of the Hüber and Onneken standards Fig. 4 nterfaces of the worksheet and the data output One of the main structures elaborated in the program, shown in the Figure 5, is the routine of validation of data. This while loop structure happens so many times as they are necessary until obtaining 3
4 Simposio de Metrología al 7 de Octubre 4. RESULTS The presentation of the obtained results can be seen in Figure 4 in both interfaces of data output. n both of them the measurement averages, the standard deviation are evaluated and the other parameters already mentioned. Fig. 5 Routine of validation of data. The contribution of the uncertainty of the type is determined by the standard deviation of the measurements and it is expressed as follows: t has also been verified that the time of the automated calibration process till the emission of the certificate experienced a significant reduction of the order from 40 to 50%. n this case, the time factor depends on the operator's experience in handling of Onneken standard. esides the reduction of the calibration time, one of the advantages is the decrease of mistakes in the emission of the certificate discussed previously or the operator's interference in the same. = s mediciones () 5. CONCLUSONS From the technical data supplied in the manuals and certificates of Onneken [8] and Hüber [9] standards, it has been identified the sources that contribute to the uncertainty of the type, expressed by the following equation [5, 10, 11]: = + H + L + R + T + S + E p ob ob ob ob ob ob (3) From the Equation (3) [5], it has been verified that the sources above can be neglected without causing significant change in the final result. Once identified, the Equation (3) could be rewritten in the following way: = p + E ob (4) Thus, it can be stated that the automation of the Onneken pressure standard could improve the productivity, the execution time and the quality of the services offered by the Laboratory of Pressure of the Management of Legal Metrology. The development of projects with automated systems has contributed to the operator s improvement. CKNOWLEDGEMENTS To all those that contributed to the realization of this work in some other way, through the orientation and sharing of knowledge, the support and the motivation and friendship. REFERENCES The value of it is obtained considering the [1] NMETRO, Portaria NMETRO n.º 4, de de largest value of the column D.Pad, in the Média das Medições, shown in the Figure 4-, it is determined as follows: fevereiro de 1996, que a Regulamentação Técnica Metrológica sobre Esfigmomanômetros neróides de Medição Não-nvasiva, Rio de Janeiro RJ ( ) = s Seq1c + s Seq1d + s Seqc + s Seqd (5) [] VUOLO, José Henrique, Fundamentos da Teoria dos Erros, São Paulo: Edgard lücher, 1998 nd it is intended that the measurement uncertainty, for the automated process, of the calibration of Onneken standard is given as: = M Seq1c Seq1d Seqc Seqd + (6) [3] NTONL NSTRUMENTS, Manual do LabView 6.1 Professional Edition, 00 [4] NTONL NSTRUMENTS, Manual do Report Generation for LabView, 00 4
5 Simposio de Metrología al 7 de Octubre [5] CHGS D SLV, Mônica; SLVNO D SLV, Marcos., nálise da Contribuição de Cada Fonte de ncerteza na Calibração do Padrão de Trabalho Onneken, METROSUL Curitiba PR; 00 [6] FLESCH, Carlos lberto; postila de Metrologia e Eletrônica ásica para Experimentação; Ed. Universidade Federal de Santa Catarina, Julho [7] PM, nternational ureau of Weights and Measures; EC, nternational Eletromechanical Commission; FCC, nternational Federation of Clinical Chemistry; SO, nternational Organization for Standardization; UPC, nternational Union of Pure and pplied Chemistry; UPP, nternational Union of Pure and pplied Physics; OML, Organização nternacional de Metrologia Legal; Guia para a Expressão da ncerteza de Medição; ª. Ed. [Rio de Janeiro], gosto [8] ONNEKEN; Operating nstructions Onneken- Calibrator Type OM S [9] HÜER NSTRUMENTE, Operating nstructions Pressure-Transfer-Standards Types PRF/PHF 3000/6000; 1994 [10] ZEREDO, Ronaldo Nunes de; SLVNO D SLV, Marcos., Determinação da ncerteza de Medição na Calibração do Padrão de Pressão Onneken, ENQUL São Paulo SP; 003 [11] LNK, Walter; Metrologia Mecânica: Expressão da ncerteza de Medição; Programa RH Metrologia; Mitutoyo
Automation of an X-ray calibration system using LabVIEW
Automation of an X-ray calibration system using LabVIEW Y.S. Rodrigues*, V. Vivolo, M.P.A. Potiens Institute of Energetic and Nuclear Research, São Paulo, 05508-000, Brazil ABSTRACT The Brazilian regulation
More informationHorizontal scale calibration of theodolites and total station using a gauge index table
Journal of Physics: Conference Series PAPER OPEN ACCESS Horizontal scale calibration of theodolites and total station using a gauge index table To cite this article: L H B Vieira et al 015 J. Phys.: Conf.
More informationCould LIDAR methods automatically detect the top of ABL? Case studies for Santa Maria / CHUVA-SUL
Could LIDAR methods automatically detect the top of ABL? Case studies for Santa Maria / CHUVA-SUL Gregori de A. Moreira¹, Eduardo Landulfo¹, Lucas Vaz Peres 2, Glauber Mariano 3, Riad Bourayou¹ ¹ Center
More informationSystematic errors Random errors
Where are we in our discussion of error analysis? Let s revisit: 1 From Lecture 1: Quick Start, Replicate Errors: Measurements are affected by errors (uncertainty) There are two general categories of errors
More informationComputer Controlled Process Control Unit for the Study of Pressure (Air), with SCADA and PID Control UCP-P
Technical Teaching Equipment Computer Controlled Process Control Unit for the Study of Pressure (Air), with SCADA and PID Control UCP-P Teaching Technique used EDIBON SCADA System and PID CONTROL included
More informationMicro calibration bath Models CTB , CTB
Calibration technology Micro calibration bath Models CTB9100-165, CTB9100-225 WIKA data sheet CT 46.30 for further approvals see page 3 Applications Calibration in the pharmaceutical industry and in the
More informationHand-held thermometer Model CTH6200
Calibration technology Hand-held thermometer Model CTH6200 WIKA data sheet CT 51.01 Applications Calibration service companies and service industry Measurement and control laboratories Industry (laboratory,
More informationDEVELOPMENT OF AN ANALOGICAL AND DIGITAL TAPE AND SCALE CALIBRATOR AND THE COMPARISON BETWEEN CALIBRATION METHODS
XVII IMEKO World Congress Metrology in the 3 rd Millennium June 22 27, 2003, Dubrovnik, Croatia DEVELOPMENT OF AN ANALOGICAL AND DIGITAL TAPE AND SCALE CALIBRATOR AND THE COMPARISON BETWEEN CALIBRATION
More information41126 Cognento (MODENA) Italy Via Bottego 33/A Tel: +39-(0) Internet: Fax: +39-(0) ENGLISH
41126 Cognento (MODENA) Italy Via Bottego 33/A Tel: +39-(0)59 346441 Internet: http://www.aep.it E-mail: aep@aep.it Fax: +39-(0)59-346437 ENGLISH OPERATIVE MANUAL PressKAL Release 2.8 Application software
More informationTransforming Data into Information at Right Time Right
MICROWARE S SUCCESS CASE CLIENT: SUSEP - Superintendência de Seguros Privados INDUSTRY Government Transforming Data into Information at Right Time Right SUSEP expands its Datacenter structure and acquire
More informationUSB pressure transmitter model CPT2500 with model CPA2500 USB adapter and USBsoft2500 software
Calibration technology www.materm.si tel: 02 608 90 10 with model CPA2500 USB adapter and USBsoft2500 software WIKA data sheet CT 05.01 Applications Calibration service companies and service industry Quality
More informationElectronic pressure switch with display For sanitary applications Model PSA-31
Electronic pressure measurement Electronic pressure switch with display For sanitary applications Model PSA-31 WIKA data sheet PE 81.85 Applications Food and beverage industry Pharmaceutical industry Filling
More informationTemperature dry-well calibrator Models CTD9100-COOL, CTD , CTD , CTD
Calibration technology Temperature dry-well calibrator Models CTD9100-COOL, CTD9100-165, CTD9100-450, CTD9100-650 WIKA data sheet CT 41.28 for further approvals see page 4 Applications Easy on-site calibration
More informationTemperature dry-well calibrator Models CTD9100-COOL, CTD , CTD , CTD
Calibration Temperature dry-well calibrator Models CTD9100-COOL, CTD9100-165, CTD9100-450, CTD9100-650 WIKA data sheet CT 41.28 for further approvals see page 4 Applications Easy on-site calibration Power
More informationComputer Controlled Process Control Unit for the Study of Pressure (Air) UCP-P
Technical Teaching Equipment Computer led Process Unit for the Study of Pressure (Air) UCP-P Always included in the supply: Teaching Technique used SCADA. EDIBON Computer System Unit: UCP-P. Process Unit
More informationA NEW SYSTEM FOR COMPARISON CALIBRATION OF VIBRATION TRANSDUCERS AT LOW FREQUENCIES
XIX IMEKO World Congress Fundamental and Applied Metrology September 6 11, 2009, Lisbon, Portugal A NEW SYSTEM FOR COMPARISON CALIBRATION OF VIBRATION TRANSDUCERS AT LOW FREQUENCIES Gustavo P. Ripper,
More informationMiniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm
Electronic pressure measurement Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm WIKA data sheet PE 81.25 for further approvals see page 5 MicroTronic
More informationOperating Manual. English. Digital-Analog Converter DACON8-UMB.
English Digital-Analog Converter www.lufft.de G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany. We reserve the right to amend technical specifications at any time. Contents 1 Please Read Before
More informationPneumatic precision pressure controller Model CPC6000
Calibration technology Pneumatic precision pressure controller Model CPC6000 WIKA data sheet CT 27.61 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers
More informationIntroduction to Metrology
IPE 381 Introduction to Metrology Abdullah-Al-Mamun Lecturer, Dept. of IPE Outline What is Metrology Different types of Metrology Precision and accuracy Sources of errors Nano metrology 1 What is Metrology
More informationTESA UPD Gauge Block Comparator with a 25 mm Measuring Span
TESA UPD Gauge Block Comparator with a 25 mm Measuring Span Direct measurement of gauge blocks with a variation in nominal length of up to 25 mm or 1 in. Allows the number of required reference gauge blocks
More informationTelecom Innovation In Mobile Health Units. Leonardo Melo CEO and Founder diagnext.com
Telecom Innovation In Mobile Health Units Leonardo Melo CEO and Founder diagnext.com Disclosure Leonardo Melo Financial Relevant Relationship:. Financial support, laboratories and trained personnel from
More informationHand-held thermometer, industrial version Model CTH6300 Model CTH63I0, Ex version
Calibration technology Hand-held thermometer, industrial version Model CTH6300 Model CTH63I0, Ex version WIKA data sheet CT 51.05 for further approvals see page 2-3 Applications Calibration service companies
More informationEstablishing a Validated Automated System for Attenuation Measurement at DC-18GHz Frequencies
International Journal of Information and Computation Technology. ISSN 0974-2239 Volume 3, Number 6 (2013), pp. 521-526 International Research Publications House http://www. irphouse.com /ijict.htm Establishing
More informationPressure transmitter for mobile hydraulic applications With output signals CANopen and J1939
Electronic pressure measurement Pressure transmitter for mobile hydraulic applications With output signals CNopen and J1939 Model MHC-1 WIK data sheet PE 81.49 pplications Construction machinery gricultural
More informationProcessCalibrator Model CPH6000
Calibration technology ProcessCalibrator Model CPH6000 WIKA data sheet CT 15.01 Applications Calibration service companies/service industry Maintenance facilities Measurement and control laboratories Quality
More informationExcel Functions & Tables
Excel Functions & Tables Fall 2014 Fall 2014 CS130 - Excel Functions & Tables 1 Review of Functions Quick Mathematics Review As it turns out, some of the most important mathematics for this course revolves
More informationHand-held thermometer Model CTH6200
Calibration technology Hand-held thermometer Model CTH6200 WIKA data sheet CT 51.01 for further approvals see page 3 Applications Calibration service companies and service industry Measurement and control
More informationTTC Series Torque Tool Tester Operation Manual
TTC Series Torque Tool Tester Operation Manual Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test. Whether the unit is ON or OFF,
More informationComputer Controlled Unit for the study of a Refrigeration Circuit with Variable Load, with SCADA TRCAC
Technical Teaching Equipment Computer Controlled Unit for the study of a Refrigeration Circuit with Variable Load, with SCADA TRCAC EDIBON SCADA System Teaching Technique used 2 Control Interface Box 5
More informationDigital pressure gauge Data Sheet: DMM2.431.R1.EN
Data Sheet: DMM.431.R1.EN www.aep.it Digital pressure gauge DMM is a digital pressure gauge made according to the most modern technologies to ensure a high level of reliability, versatility and practicality
More informationDEVELOPMENT OF A PARAMETRIC PROGRAM FOR SIMULATION OF THE STAMPING PROCESS USING FINITE ELEMENTS METHOD
DEVELOPMENT OF A PARAMETRIC PROGRAM FOR SIMULATION OF THE STAMPING PROCESS USING FINITE ELEMENTS METHOD Erick Siqueira Guidi, eguidi@uol.com.br Fernando de Azevedo Silva, fazevedo@feg.unesp.br UNESP São
More informationISO INTERNATIONAL STANDARD. Test code for machine tools Part 4: Circular tests for numerically controlled machine tools
INTERNATIONAL STANDARD ISO 230-4 Second edition 2005-04-01 Test code for machine tools Part 4: Circular tests for numerically controlled machine tools Code d'essai des machines-outils Partie 4: Essais
More informationPressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2
Electronic pressure measurement Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2 WIKA data sheet PE 81.53 Applications Test bench construction Water jet
More informationProducts Used: LabVIEW DAQ SCXI
EcoMonitor Air Quality Continuous Monitoring System by José P. Caetano, Ricardo J. Jesus, Pedro A. Alves, Victor F. Dias System Developers INESC, Lisbon, Portugal Products Used: LabVIEW DAQ SCXI The Challenge:
More informationTiming Analysis of Automatically Generated Code by MATLAB/Simulink
Timing Analysis of Automatically Generated Code by MATLAB/Simulink Rômulo Silva de Oliveira, Marcos Vinicius Linhares, Ricardo Bacha Borges Systems and Automation Department - DAS Federal University of
More informationCALIBRATION: PRIMARY, SECONDARY, AND FIELD
FIFTH INTERNATIONAL CONGRESS ON SOUND AND VIBRATION DECEMBER 15-18, 1997 ADELAIDE, SOUTH AUSTRALIA CALIBRATION: PRIMARY, SECONDARY, AND FIELD Ernst Schonthal The Modal Shop G.R.A.S. Sound& c/o PCB Piezotronics,
More informationThe Evaluation Method for Software Product
The Evaluation Method for Software Regina Colombo e-mail: regina.thienne@cenpra.gov.br UNICAMP - Universidade Estadual de Campinas Faculdade de Engenharia Mecânica Caixa Postal 6122 CEP: 13.083-970 Campinas,
More informationInstruction Manual. Sound Calibrator 42AB. LI0062 Revision 30 April 2012
Instruction Manual Sound Calibrator 42AB www.gras.dk Revision History Any feedback or questions about this document are welcome at gras@gras.dk. Revision Date Description 1 October 2002 First publication
More informationPrecision thermometer Model CTR2000
Calibration technology Precision thermometer Model CTR2000 WIKA data sheet CT 60.10 Applications Precision thermometer for very accurate temperature measurements in a range of -200... +962 C Reference
More informationPRC Coordination of Protection Systems for Performance During Faults
PRC-027-1 Coordination of Protection Systems for Performance During Faults A. Introduction 1. Title: Coordination of Protection Systems for Performance During Faults 2. Number: PRC-027-1 3. Purpose: To
More informationPrecision hand-held pressure indicator Model CPH6400
Calibration technology Precision hand-held pressure indicator Model CPH6400 WIKA data sheet CT 14.01 Applications Calibration service companies and service industry Measurement and control laboratories
More informationVACUUM METER Model : VC-9200
VACUUM METER Model : VC-9200 Your purchase of this VACUUM METER marks a step forward for you into the field of precision measurement. Although this METER is a complex and delicate instrument, its durable
More informationPneumatic precision pressure controller Model CPC6000
Calibration technology Pneumatic precision pressure controller Model CPC6000 WIKA data sheet CT 27.61 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers
More informationElectronic pressure switch with display For sanitary applications Model PSA-31
Electronic pressure measurement Electronic pressure switch with display For sanitary applications Model PSA-31 WIKA data sheet PE 81.85 for further approvals see page 8 Applications Food and beverage industry
More informationElectronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Pressure Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics and pneumatics Pumps and
More informationAWA6223S Sound Level Calibrator. Instruction Manual HANGZHOU AIHUA INSTRUMENTS CO., LTD
AWA6223S Sound Level Calibrator Instruction Manual HANGZHOU AIHUA INSTRUMENTS CO., LTD Notes 1. Please read the instruction carefully before using the instruments for the first time. 2. The calibrator
More informationBoosting the Efficiency of Wind Power Plants. Stringent Demands for Boosting the Efficiency of Wind Power Plants
Case Study Boosting the Efficiency of Wind Power Plants By Steffen Schenk and Wolfgang Steindorf Three-dimensional measurement and analysis of rotor blades and their production facility are highly complex
More informationDMT PERFORMING UNDER PRESSURE DMT. With USB adapter and software. Applications. Special features. Description 1/7
Applications With USB adapter and software Calibration service companies and service industry Quality assurance Recording and monitoring of pressure processes Measurement of pressure peaks Special features
More information6220 Ethernet-Based Voltage Measurement Module
6220 Ethernet-Based Voltage Measurement Module Features 12 voltage inputs 16-bit, 100-kHz per channel sample rate ±10V input range Eight digital I/O Simultaneous sampling BNC connectors Multiple trigger
More informationCole-Parmer Instrument Company
Operating Instructions Cole-Parmer ph/orp 400 ph/orp Controller Cole-Parmer Instrument Company 625 East Bunker Court, Vernon Hills, Illinois 60061 Tel: 1-847-549-7600 or Toll-free: 1-800-323-4340 Fax:
More informationQuality Control of a Dam Geodetic Surveying System
Quality Control of a Dam Geodetic Surveying System Maria João HENRIQUES and João CASACA, Portugal Key words: Geodetic Surveying Systems, Monitoring Displacements, Quality Control. SUMMARY Geodetic surveying
More informationField Metrology Wells
Field Metrology Wells Technical Data Recently, we introduced Metrology Wells, which provide the very best performance in portable temperature calibration. The new 914X Series Field Metrology Wells extend
More informationPortable low-pressure controller Model CPC2000
Calibration technology Portable low-pressure controller Model CPC2000 WIKA data sheet CT 27.51 Applications Mobile calibration of low-pressure measuring instruments Supply of very low positive or negative
More informationENERGY STAR Program Requirements Product Specification for Imaging Equipment. Test Method for Determining Imaging Equipment Energy Use Rev.
ENERGY STAR Program Requirements Product Specification for Imaging Equipment Test Method for Determining Imaging Equipment Energy Use Rev. Sep-2014 1 OVERVIEW The following test method shall be used for
More informationElectronic pressure switch with display For sanitary applications Model PSA-31
Electronic pressure measurement Electronic pressure switch with display For sanitary applications Model PSA-31 WIKA data sheet PE 81.85 Applications Food and beverage industry Pharmaceutical industry Filling
More informationPneumatic precision pressure controller Model CPC6000
Calibration technology Pneumatic precision pressure controller Model CPC6000 WIKA data sheet CT 27.61 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers
More informationEUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL
EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL New Approach Industries, Tourism and CSR Construction, Pressure Equipment, Metrology Brussels, 21 st December 2009 M/457 EN Standardisation
More informationAPO_WI A laboratory scale & a weight recorder in the same instrument
New electronic balance APO_WI is the right tool to characterize a batch of fruits & vegetables considering weight Congratulations for having acquired an APO_WI! Your box contains: Mark and patent registered.
More informationPneumatic High-Speed Pressure Controller Model CPC3000
Calibration Technology Pneumatic High-Speed Pressure Controller Model CPC3000 02/2014 Applications Industry (laboratory, workshop and production) Pressure transmitter manufacture Calibration service companies
More informationSCADA. EDIBON Computer Control System: Computer Control + Data Acquisition + Data Management Cables to. Cable to computer. Control.
Technical Equipment Computer led Heat Pump Unit (one condenser (water) and one evaporator (water)) THBLLC Always included in the supply: SCADA. EDIBON Computer System 2 Interface Box 5 Cables and Accessories
More informationStandard Development Timeline
Standard Development Timeline This section is maintained by the drafting team during the development of the standard and will be removed when the standard becomes effective. Description of Current Draft
More informationPressure sensor For highest pressure applications to 15,000 bar Model HP-2
Pressure Pressure sensor For highest pressure applications to 15,000 bar Model HP-2 WIKA data sheet PE 81.53 for further approvals see page 6 Applications Test bench construction Water jet cutting High-pressure
More informationCalibratorUnit Models CPU6000-W, CPU6000-S, CPU6000-M
Calibration technology CalibratorUnit Models CPU6000-W, CPU6000-S, CPU6000-M WIKA data sheet CT 35.02 Applications Determination of the required masses or the reference pressure for calibration with pressure
More informationPortable pressure calibrator Model CPH7600
Calibration technology Portable pressure calibrator Model CPH7600 WIKA data sheet CT 17.01 Wally Box III Applications Calibration service companies and service industry Measurement and control laboratories
More informationMedium-Voltage Drive SINAMICS SM150. Type 6SL3845. Tests carried out on drives This documentation pertains to SM150 wassergekühlt G20 F03 F72 F79 F76
Tests carried out on drives This documentation pertains to SM150 wassergekühlt G20 F03 F72 F79 F76 Reference Manual Medium-Voltage Drive SINAMICS SM150 Type 6SL3845 Edition 02/2019 www.siemens.com/drives
More informationn Measuring range 0... ± 0,02 Nm to 0... ± 1000 Nm n Low linearity deviation of ± 0.05 % F.S. n Intelligent operating state indicator
Precision Torque Sensor Non-contact transmission for rotating applications Optional measurement of angle and speed Model 8661 Code: Delivery: Warranty: 2-3 weeks 24 months Optional: USB interface Dual
More informationEDSC. Computer Controlled Teaching Machine for Putting into a Container Solids, with SCADA. Key features:
Engineering and Technical Teaching Equipment Computer Controlled Teaching Machine for Putting into a Container Solids, with SCADA EDSC Teaching Technique used EDIBON SCADA System 2 Control Interface Box
More informationIndustrial pressure controller Model CPC4000
Calibration technology Industrial pressure controller Model CPC4000 WIKA data sheet CT 27.40 Applications Oil and gas industry Industry (laboratory, workshop and production) Transmitter and pressure gauge
More informationField Metrology Wells
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Field Metrology Wells Technical Data Recently, we introduced Metrology Wells, which
More informationColorado Series. CR-10 Portable ph / mv / Temperature Meter Operation Manual
Colorado Series CR-10 Portable ph / mv / Temperature Meter Operation Manual 2 Contents Page General Introduction and Initial Inspection.............................. 4 Safety Infomation..................................................
More informationSCC-AO10 Isolated Analog Output Module
USER GUIDE SCC-AO10 Isolated Analog Output Module Conventions The SCC-AO10 is an isolated voltage output module with an output range of ±10 V. The output voltage level is controlled by the DAC output of
More informationDMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9
Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers Calibration service companies and service industry Research and development laboratories National
More informationManual of Electrical Installation for Pressure Probes KS and KS-SIL2 series
Manual of Electrical Installation for Pressure Probes KS and KS-SIL2 series GEFRAN SAFETY GUARANTEE Code 8594A Edition 2/204 Contents. General precautions pag 2 2. Transmitters with amplified analog output
More informationHumidiProbe User Guide
HumidiProbe User Guide 2005 Pico Technology Limited. All rights reserved. HumidiProbe044-1.3 I HumidiProbe User Manual Contents 1 Introduction...2...2 1 About HumidiProbe...2 2 Intended use...2 3 This
More informationHarris: Quantitative Chemical Analysis, Eight Edition CHAPTER 05: QUALITY ASSURANCE AND CALIBRATION METHODS
Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 05: QUALITY ASSURANCE AND CALIBRATION METHODS 5-0. International Measurement Evaluation Program Sample: Pb in river water (blind sample) :
More informationHD B. [ GB ] Precision Barometer
HD 9408.3B [ GB ] Precision Barometer [ GB ] [ GB ] Characteristics High accuracy temperature-compensated sensor with excellent stability Wide temperature operating range Various output options available
More informationUSB/RS-485 INTERFACE CONVERTER PD10 TYPE USER S MANUAL
USB/RS-485 INTERFACE CONVERTER PD10 TYPE USER S MANUAL Contents 1. APPLICATION... 5 2. CONVERTER SET... 5 3. CONVERTER INSTALLATION... 6 3.1. Converter installation and safety requirements... 6 3.2. Description
More informationDESCRIPTION. DataApex Clarity 32bit multi instrument chromatography station for Windows
wwwdataapexcom e-mail: clarity@dataapexcom DESCRIPTION DataApex Clarity 32bit multi instrument chromatography station for Windows Multi-detector instruments Easy to install and easy to use Graphical user
More informationManaging Database Services: An Approach Based in Information Technology Services Availabilty and Continuity Management
ISSN: 2468-4376 Managing Database Services: An Approach Based in Information Technology Services Availabilty and Continuity Management 1 Universidade de Fortaleza, BRAZIL Leonardo Bastos Pontes 1 *, Adriano
More informationProcessCalibrator Model CPH6000
Calibration technology ProcessCalibrator Model CPH6000 WIKA data sheet CT 15.01 Applications Calibration service companies/service industry Maintenance facilities Measurement and control laboratories Quality
More information1601 North A.W. Grimes, Suite B Round Rock, TX (512) Fax: (512) January 20, 2012
1601 North A.W. Grimes, Suite B Round Rock, TX 78665 e-mail: info@ptitest.com (512) 244-3371 Fax: (512) 244-1846 January 20, 2012 Mr. Bobby Wollard Dynamic Flow Computers 12603 Southwest Freeway Suite
More informationHigh-end pressure controller Model CPC8000
Calibration technology High-end pressure controller Model CPC8000 WIKA data sheet CT 28.01 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers Calibration
More informationGELINA Stability program (GESTA)
GELINA Stability program (GESTA) Technical description of the GESTA application developed at IRMM D. Vendelbo, P. Schillebeeckx 2012 Report EUR 25509 EN European Commission Joint Research Centre Institute
More informationPreliminary Lab Exercise Part 1 Calibration of Eppendorf Pipette
Preliminary Lab Exercise Part 1 Calibration of Eppendorf Pipette Pipettes allow transfer of accurately known volume of solution from one container to another. Volumetric or transfer pipettes deliver a
More informationElectronic pressure switch with display Model PSD-4
Electronic pressure measurement Electronic pressure switch with display Model PSD-4 WIKA data sheet PE 81.86 Applications Machine tools Hydraulics and pneumatics Pumps and compressors Special-purpose machine
More informationTemperature dry-well calibrator Models CTD , CTD
Calibration technology Temperature dry-well calibrator Models CTD9300-165, CTD9300-650 WIKA data sheet CT 41.38 for further approvals see page 3 Applications Bio and pharmaceutical industries Food industry
More informationWarner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax
CL-100 Manual, Rev. 050815.2 Bipolar Temperature Controller Model CL-100 1125 Dixwell Avenue, Hamden, CT 06514 (800) 599-4203 / (203) 776-0664 (203) 776-1278 - fax CL-100 Manual, Rev. 050815.2 Table of
More informationExcel Functions & Tables
Excel Functions & Tables Fall 2012 Fall 2012 CS130 - Excel Functions & Tables 1 Review of Functions Quick Mathematics Review As it turns out, some of the most important mathematics for this course revolves
More informationHigh-end pressure controller Model CPC8000
Calibration technology High-end pressure controller Model CPC8000 WIKA data sheet CT 28.01 Applications Industry (laboratory, workshop and production) Transmitter and pressure gauge manufacturers Calibration
More informationUSER GUIDE. Model Noise Dosimeter with PC Interface
Noise Dosimeter with PC Interface Model 407355 USER GUIDE Extech 407355 Noise Dosimeter Data Logger & PC Interface Extech 407355-Kit-5 Noise Dosimeter/Datalogger Kit Extech 407355-NIST Noise Dosimeter
More informationDWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.
Series AVUL Air Velocity Transmitter Specifications - Installation and Operating Instructions Bulletin P-AVUL 3-49/64 [95.71] 2-43/64 [67.92] 1/2 NPS 3-3/16 [80.81] 1-19/32 [40.59] 31/32 24.58 3-33/64
More informationThermometer T12. Precision Multichannel Thermometer System. Typical applications: REFLECTING YOUR STANDARDS
Precision Multichannel Thermometer System Twelve channel temperature measurement High precision, stability and repeatability Internal reference resistors PC software for system control and data acquisition
More informationOperating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO
Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...
More informationJAI PRAKASH UNIVERSITY, CHAPRA (Department of Examination)
JA PRAKASH UNERSTY, CHAPRA Revised Programme for B.Tech. Part- Examination 2011. Centre: D.A.. College, Siwan. 08.08.2011 Technical English 10.08.2011 Mathematics- 12.08.2011 Mathematics 16.08.2011 Chemistry
More informationA Procedure for accuracy Investigation of Terrestrial Laser Scanners
A Procedure for accuracy Investigation of Terrestrial Laser Scanners Sinisa Delcev, Marko Pejic, Jelena Gucevic, Vukan Ogizovic, Serbia, Faculty of Civil Engineering University of Belgrade, Belgrade Keywords:
More informationCALIBRATION OF DIFFRACTOMETERS: A TEST METHOD TO MONITOR THE PERFORMANCE OF INSTRUMENTS. G. Berti, U. Bartoli, M. D Acunto and F.
Materials Science Forum Online: 004-01-15 ISSN: 166-975, Vols. 443-444, pp 7-30 doi:10.408/www.scientific.net/msf.443-444.7 004 Trans Tech Publications, Switzerland CALIBRATION OF DIFFRACTOMETERS: A TEST
More informationPrecision digital pressure gauge Model CPG1500
Calibration technology Precision digital pressure gauge Model CPG1500 WIKA data sheet CT 10.51 for further approvals see page 4 Applications Oil and gas industry Maintenance and service facilities Calibration
More informationRSS for Windows Software
RSS for Windows Software User s Manual Research Pneumotach System January 21, 1999 Catalog No. 2000-10 Copyright 1997 KORR Medical Technologies Inc. Salt Lake City, Utah, U.S.A. 84109 All rights reserved.
More informationHumidity goes Digital
Industrial Humidity Temperature Transmitter Dew-point and other calculated values Wide range of digital interchangeable probes No need for field calibration PC compatible and RS485 networkable SWISS MADE
More information