1 103 Quality Circle, Suite 215 Huntsville, AL Phone: (256) Fax: (256) Website: AxoStep TM Imaging Mueller Matrix Polarimeter OPERATOR S SOFTWARE MANUAL 2012 All rights reserved. AxoStep, AxoScan, Axometrics and the Axometrics logo are trademarks of

2 ii

3 Please read these instructions completely and carefully before operating the Mueller Matrix Polarimeter. If you have any questions, or experience any difficulties, please contact Axometrics or the representative from whom the instrument was purchased. iii

4 iv

5 CONTENTS 1 Introduction Installed Software Instrument Files Directory The AxoStep Viewer Graphical User Interface (GUI) Main Image Options Tab Registration Tab Manual Registration Auto Registration Define a reference angle Mask Tab Threshold Mask Selected Area Measurement Tab Single Measurement Tilt Scan Measurements Wavelength Scan Measurements Rotation Scan Measurements XY Scan Measurements XY Stage Tab Calibration Tab Automatic Calibration Advanced Calibration Functions Before Version Polarimeter Coordinate System Toolbars Basic Tools measurement information Cross section plots Poincare sphere D plot Statistics reduced parameters edge detection Optical Gauging Measurement image measurements user defined Calculation Launch AxoStep Auto Calibrate launch tip tilt controller launch X-y controller Image through Crossed Polarizer Pitch Measurement Utility apply retardance order Rth calculation LCD tools Mapping selection Menu Bar File menu Edit menu view menu Tools menu hardware menu

6 Help menu Special Notes on Testing Polarization Elements CAL-VIS-1 Reference Retarder CAL-VIS-2 Reference Polarizer LCD Production Define a Pixel Perform a Test Measurement Define your output Regions Configure the Output Regions Configure the Robots x,y Coordinates Setup Discrete Holes Tilt, Rotation Angles Wavelengths Perform a Test Measurement Appendix Reduced Parameters Retardance Diattenuation Calculated Parameters A Note about Retardance Order and Unwrapping

7 1 INTRODUCTION The AxoStep Imaging Mueller Matrix Polarimeter is an optical instrument for capturing and image of all of the polarization properties of a sample. A sequence of intensity images are acquired as retarders rotate within the Polarization State Generator and the Polarization State Analyzer heads. These images are then processed to calculate the 16 two dimensional arrays that comprise the Mueller Matrix Image of the sample which characterizes all of the polarization transformations for that sample. A single or sequence of Mueller Matrix Images can be saved to a file for analysis in other computer programs. A Mueller Matrix image is generally identical to an XY map of Mueller Matrices obtained using an AxoScan system. There are two superficial features that distinguish a Mueller Matrix Image from a Mueller Matrix XY Map 1. The Mueller Matrix Image is generally contains a much larger grid of points (usually greater than 100x100), and will always be arranged in a rectangular array. 2. The Mueller Matrix image generally measures a much smaller area (less than 2cm) than a typical XY map. Nevertheless, apart from these superficial features, the data contained in a Mueller Matrix image and the data contained XY map is identical. 1.1 Installed Software The following software has been installed on the Control Unit computer: Licensed copy of Microsoft Windows operating system AXOSTEP ENGINE and related configuration files AXOSTEP VIEWER and related configuration files Any optional Axometrics Software This manual describes all of the features in the AxoStep Viewer software package which is used to analyze Mueller Matrix Image datasets, and can control the AxoStep Engine via TCP/IP communication for performing basic measurement tasks. While installing additional software (such as data analysis software, word processors, etc.) on the dedicated Control Unit computer is unlikely to affect the polarimeter, Axometrics discourages installing additional software, especially software that may run background processes causing the instrument program to compete for system resources thereby degrading instrument performance. In the event of a catastrophic computer problem it may be necessary to reinstall the operating system or reformat the hard drive. Please contact Axometrics for detailed instructions or assistance. 1.2 Instrument Files Directory All AxoStep instrument program files and support files are located at the following directory: C:\AxoView\Current Version Do not change directory locations or filenames.. 3

8 2 THE AXOSTEP VIEWER GRAPHICAL USER INTERFACE (GUI) The AxoStep Viewer GUI is the main control program which acquires data, provides data visualization (2D image, 3D image, cross section plot and on the Poincaré sphere), streams the measurements to disk, and creates measurement reports. The AxoStep Viewer can be used to analyze individual Mueller Matrix Image datasets as well as scans of multiple ones. Each Mueller Matrix Image is a multiple dimensional dataset containing 38 individual data images consisting of 16 images corresponding to the Mueller Matrix elements and 22 images corresponding to Reduced Parameter Images (Such as Retardation, Diattenuation, etc). The main screen of the AxoStep Viewer GUI is shown in the following figure. 2.1 Main Image On the front panel of the AxoStep Viewer program is the main image window. 4

9 Current Image: Allows the user to select between multiple Mueller Matrix Image datasets that are currently available (such as multiple images from a scan measurement). Parameter to Plot: Allows the user to select between multiple parameters to show, like elements of Mueller Matrix and calculated parameters from Mueller Matrix Image that are currently available. Current Parameter: Shows the parameter that is currently selected. The user can change how the current parameter to be shown (like adjusting the data range) on the Options Tab (described below). The user can also directly change the value on the color map to adjust the data range. The user needs to adjust the data range in order to see some feature on some samples. Otherwise the feature cannot be seen on the intense background. Cursor Location: Shows the location of the cursor in units of pixels or actual units. User can select which unit is shown on the Program Options from the Tools menu. For showing the actual units (µm or mm), user needs to set what objective is using on the Calibration Tab of AxoStep Engine. Parameter Value: Shows the parameter value at the current cursor location. Convenient Buttons: Allows the user to access the frequently used buttons. The details about each button will be described in the following sections. Parameter Category: Allows the user to choose which kind of parameters to plot, reduced parameter (like total retardance) or calculated parameter (like Rth). Picture Controls: The following picture controls are available. Cursor Control: Generates the cross-hair cursor shown in the image above. Zoom in control: Allows the user to zoom into a selected area. 5

10 Drag control: Allows the user to drag the magnified view. Line control: Draws a line on the image. Box control: Selects a rectangular region in the image. Circle control: Selects a circular region in the image. Unzoom control: Returns the view to the full image. 2.2 Options Tab Sometimes the user needs to adjust the data range in order to see some features on some samples. Otherwise the features cannot be seen on some background. Options tab shown below provides the controls to adjust the data range. Smart Autoscale: Set the data range on the image to be following scales. Range (Max-Min): Set the data range on the image to be possible maximum and minimum value. 6

11 Standard Deviation: Set the image scale to be ±N standard deviations from the mean value. A value of 0 means to autoscale over the full range. Percentage: Set the image scale such that N percent of the pixels lie within the color range. Sort Images: Sort the scanned or multiple images in the different order, like Tilt Angle, Rotation Angle, Wavelength, XY scan, etc. 2.3 Registration Tab In order to calculate Rth or LC cell parameters from tip-tilt measurements, sometimes user needs to perform the registration (alignment) for multiple images from a scan measurement or multiple single measurements. The controls in the Registration tab are shown below. Manual Registration By Distance Manual Registration By Coordinates Auto Registration Define a Reference Angle 7

12 2.3.1 MANUAL REGISTRATION Delta X: Set the number of pixels to translate in the X-direction. Delta Y: Set the number of pixels to translate in the Y-direction. Translate: Translate the current image by Delta X and Delta Y. : Translate the current image step by step. Define Point: Define a reference point using the current cursor location. Select the reference point on or near a clear reference feature in the image. Translate to point: Translate the current point to the location of the reference point. Change images and move the cursor to the same reference feature in the new image. When you press the Translate to Point button, the new image will align with the previous image. Repeat this procedure for each image in the scan dataset AUTO REGISTRATION Auto registration uses a Fourier transform correlation algorithm ( to automatically register all the images currently available. Auto Registration Type: The user can select between 1 dimensional correlation along X or Y (used on images that are only variable in 1-dimension, such as striped retarders) and generalized 2-dimensional correlation (used on images that are variable in 2-dimension, such as LCD pixels). Registration Parameter: The user needs to select the parameter that will be used to perform the image correlation. It is recommended to select a parameter that has high contrast that does not change appreciably from image to image (such as transmittance on LCD cells, or retardance orientation on patterned retarders) Reference Image for Registration: This is the image that the others will be aligned to. This image will not be translated. Auto Register: Perform the auto registration process DEFINE A REFERENCE ANGLE The user can define a reference angle so that the orientations, such as Retardance and Diattenuation Orientation, can be clearly shown with respect to a clear reference feature in the image. After the reference angle is defined, the user can select the User Defined Orientation (Retardance, Diattenuation and Polarizance) from Parameter to Plot list to be shown in current image. Define Angle: Define the reference angle by drawing a straight line using Line Control. 8

13 Coordinates: Choose a coordinate (AxoStep or Image) in which the angle is given. 2.4 Mask Tab Use the Mask tab to define a masked area where data points within that area are ignored so that the user can focus on the important part of data images. There are two mask types available. 1. Threshold Mask: The masked pixels are defined by the measurement values of the image. Masked data points can either be inside a parameter range, or outside a parameter range. 2. Selected Area Mask: The masked pixels are either inside, or outside an area selected by the user using either the box tool or circle tool. Apply Mask: Applies the currently defined mask to all of the data sets in memory. Create New Mask: Creates a mask based on the parameters set by the user (Any mask currently in memory will be erased). The Apply Mask box is automatically checked when the user presses the Create New Mask Button. Combine with current mask: When the user presses this button, the mask created by the current parameters is multiplicatively combined with the mask currently in memory. Clear Mask: Clears the current mask from memory. 9

14 2.4.1 THRESHOLD MASK. Max and Min define the range for the threshold mask. In Range will keep all pixels that are within the range defined by Max and Min. Pixels outside of this range will be masked. Out of Range keep all pixels that are outside the range defined by Max and Min. Pixels within this range will be masked. Mask Parameter is the parameter in which the range defined by Max and Min is applied to. The threshold range will be taken from the dataset currently displayed (shown in the Current Image selector on the main front panel) SELECTED AREA The Selected Area tab will create a mask defined by an area selected by the user using either the box tool or circle tool. The masked area can either be inside the selected area or outside the selected area. 2.5 Measurement Tab The controls for making basic measurements are available on the Measurement Tab. The controls in the measurement tab are shown below. 10

15 Note, the AxoStep Engine must be running to be able to perform measurements. Usually calibration is required before measuring samples. See Calibration section for the details. Single Measurements Scan Measurements SINGLE MEASUREMENT Single measurements can be performed by setting the desired Wavelength, Number to Average, Rotation Angle, Tilt Angle and Position, and pressing the Measure Once button. Note, the Tip-Tilt stage is required for setting Rotating and Tilt Angle. The XY Scan stage is required for setting the XY Position. Once the Measure Once button is pressed, the AxoStep engine will perform a single measurement, and the Tilt and Rotation Corrections are performed and the Reduced Parameters are calculated. A file dialog box will appear prompting the user to save the data as a *.cmmi file. Then, a file dialog box will 11

16 appear prompting the user to choose: add the measured data to the Current Image pull-down menu, or replace the images in the Current Image pull-down menu with measured data. The data will be the Current Image on the main front panel. Wavelength: Allows the user to set the wavelength at which the measurement is performed. Number to Average: Allows the user to select the number of images that will be acquired at every step of retarder rotation to calculate the Mueller Matrix. The larger number provides lower noise, higher measurement repeatability and longer measurement. Note, the Number to Average is different from the Measurement Steps in AxoStep Engine. The Measurement Step is the times of retarder rotation to perform a complete measurement. The default value of Measurement Steps is 40, which is the best value for most of measurements. Rotation Angle: Allows the user to set the rotation angle at which the measurement is performed. Tilt Angle: Allows the user to set the tilt angle at which the measurement is performed. X position: Allows the user to set the x position at which the measurement is performed. Y position: Allows the user to set the y position at which the measurement is performed. Use Current Position: The measurement is performed at current position TILT SCAN MEASUREMENTS Note, the Tip-Tilt stage is required for making Tilt Scan Measurements. Tilt Scan measurements are performed by selecting Tilt Scan from the Scan Type pull-down menu on the Measurement Tab. Enter the scan parameters: (Wavelength, Rotation angle, Maximum Tilt Angle, Tilt Increment, and Number to Average) 12

17 Press the Scan Button to perform the measurement. The following progress dialog box will appear. The Total Progress indicator shows which point in the scan is currently being acquired. The progress bar for Data Acquisition displays the progress of the current Mueller Matrix Image measurement being performed. The progress bar for Image Processing displays the progress of the image processing (data reduction, tilt/rotation correction) on the most recently acquired Mueller matrix image data set. Once the measurement is complete a file dialog box will appear prompting the user to save the scan data as a *.astp file. Then, a file dialog box will appear prompting the user to choose: add the scan measured data to the Current Image pull-down menu, or replace the images in the Current Image pull-down menu with the scan measured data. The scan data will be loaded into the viewer, and each scan image will become available in the Current Image pull-down menu on the main front panel WAVELENGTH SCAN MEASUREMENTS Wavelength Scan measurements are performed by selecting Wavelength Scan from the Scan Type pull-down menu on the Measurement Tab. 13

18 Enter the scan parameters: (Minimum Wavelength, Maximum Wavelength, Increment, Rotation angle, Tilt Angle, and Number to Average) Press the Scan Button to perform the measurement. A dialog box similar to the one displayed for a Tilt Scan measurement will appear. Once the measurement is complete a file dialog box will appear prompting the user to save the scan data as a *.astp file. Then, a file dialog box will appear prompting the user to choose: add the scan measured data to the Current Image pull-down menu, or replace the images in the Current Image pull-down menu with the scan measured data. The scan data will be loaded into the viewer, and each scan image will become available in the Current Image pull-down menu on the main front panel ROTATION SCAN MEASUREMENTS Note, the Tip-Tilt stage is required for making Rotation Scan Measurements. Rotation Scan measurements are performed by selecting Rotation Scan from the Scan Type pull-down menu on the Measurement Tab. Enter the scan parameters: (Wavelength, Minimum Rotation Angle, Maximum Rotation Angle, Rotation Increment, Tilt Angle, and Number to Average) Press the Scan Button to perform the measurement. A dialog box similar to the one displayed for a Tilt Scan measurement will appear. Once the measurement is complete a file dialog box will appear prompting the user to save the scan data as a *.astp file. Then, a file dialog box will appear prompting the user to choose: add the scan measured data to the Current Image pull-down menu, or replace the images in the Current Image pull-down menu with the scan measured data. The scan data will be loaded into the viewer, and each scan image will become available in the Current Image pull-down menu on the main front panel. 14

19 2.5.5 XY SCAN MEASUREMENTS Note, the XY scan stage is required for making XY Scan Measurements. XY Scan measurements are performed by selecting XY Scan from the Scan Type pull-down menu on the Measurement Tab. Enter the scan parameters: (XY Coordinates, Wavelength, Rotation Angle, Tilt Angle, and Number to Average). XY Coordinates List can be input by Load From File and Enter By Hand, through Wizard or using Discrete Holes. Press the Scan Button to perform the measurement. A dialog box similar to the one displayed for a Tilt Scan measurement will appear. Once the measurement is complete a file dialog box will appear prompting the user to save the scan data as a *.astp file. Then, a file dialog box will appear prompting the user to choose: add the scan measured data to the Current Image pull-down menu, or replace the images in the Current Image pull-down menu with the scan measured data. The scan data will be loaded into the viewer, and each scan image will become available in the Current Image pull-down menu on the main front panel. 2.6 XY Stage Tab (Requires XY stage to be installed) The XY Stage Tab, allows the user to move the XY Stage to a given position. The controls on the XY Stage Tab function just like the controls on the XY Control Utility (See Section

20 2.7 Calibration Tab The most critical aspect of precise optical metrology is the issue of calibration. Proper calibration insures that the measurements performed by your AxoStep Mueller matrix polarimeter accurately represent the physical properties of the optical samples being measured. Each instrument is calibrated by Axometrics prior to shipment, to insure proper operation. Although their effects are small, polarization properties of the Microscope Objectives do affect the measurements performed by AxoStep. Therefore, the system must be recalibrated each whenever the microscope objective is changed. Additionally, re-calibration should be performed when the PSG and PSA heads have been moved or when the bulb of the light source has changed or new PSG or PSA heads have been installed. 1. Calibration (Low Level Hardware Calibration): A procedure for completely recalibrating the optical components in the AxoStep measurement heads. Each time a Calibration is performed, a Point-By-Point Baseline is also performed. It is recommended that the system be recalibrated when any of the following have occured a. The Microscope Objective has been changed b. The Shutter Speed or Gain of the AxoStep camera has been changed. c. The PSG or PSA head has been removed or changed. 16

21 2. Spectral Orientation Calibration: This is a procedure used to define the Zero Orientation of the AxoStep system, as well as correct any systematic orientation variations that occur with respect to wavelength or X and Y Position. In general a Calculated Mueller Matrix Image (*.cmmi) file is measured of the Cal-Vis-1 for each calibrated wavelength and is stored in the software directory. The Orientation Measurement of the Cal-Vis-1 is used to correct subsequent sample measurements. 3. Baseline: (Point-by-Point Baseline) This is a procedure to correct minor polarization variations across the image. It behaves like the Baseline function used in AxoScan, except that it is applied Point-by-Point to the Mueller Matrix image.. In general a Basic Mueller Matrix Image (*.bmmi) file is measured of an Empty Sample compartment (In-Air) for each calibrated wavelength and is stored in the software directory. The stored baseline is used to correct subsequent sample measurements. The Calibration Tab (basic mode) has just three controls. Baseline: Performs the same function as the Baseline Button described in Section Auto Calibrate: The Auto Calibrate button is described in Section Show Advanced Calibration Function: Displays the Advanced Calibration Function described in Section AUTOMATIC CALIBRATION To perform a user-configured Calibration press the Auto Calibrate button on the toolbar, 17

22 or the AutoCalibrate Button on the Calibration Tab To Configure the operation of the Auto Calibrate button, Open the Program Options by selecting Tools>Program Options from the pulldown menus on the AxoStep Viewer main window The Calibration procedure will be performed in accordance with the Options that are selected in this configuration window. Clear Full Calibration: Performs the same function as the Clear Calibration Button described in Section Perform Dark Current Measurement: Performs the same function as the Dark Image Button described in Section Automatically Move XY when Calibrating: (Only on fixtures with an XY table) When this box is checked, the stage will automatically move to the proper XY position for calibration. That is, the stage will automatically move to the Cal-In-Air position when performing basic calibration, and move to the Cal- Vis-1 Position when performing orientation calibrations. Perform Calibration only at {wavelength}: Performs the same function as the Single Calibrate Button described in Section

23 Perform Full Spectrum Calibration from {min wavelength} to {max wavelength}: Performs the same function as the Spectral Calibration Button described in Section Perform Orientation Calibration Only at {wavelength}: Performs an Orientation calibration at the wavelength currently set in the Single Measurement Setting2 (Section 2.5.1) Perform Spectrum Orientation Calibration from {min wavelength} to {max wavelength}: Performs the same function as the Spectral Orientation Button described in Section Each of the Options is basically equivalent to Pressing a Button on the Calibration Tab in the main AxoStep Viewer window (Advanced Functions). For Example, if you make the following selections. Then Pressing the Auto Calibrate button is equivalent to pressing the following sequence buttons on the Calibration Tab: Pressed 1st Pressed 2nd Pressed 3rd Pressed 4th ADVANCED CALIBRATION FUNCTIONS 19

24 Baseline: Allows the user to perform a baseline measurement at the current wavelength. The checkbox allows the user to perform a baseline at measurement tilt and rotation angles. If the checkbox is unchecked, the baseline measurement is performed at the normal incidence. Clear Calibration: This will completely clear the current calibration in the AxoStep Memory. After pressing this button, you will need to re-calibrate you system before any additional measurements can be performed. Dark Image: Allows the user to measure a new dark image with the light source shutter closed. Usually this is the first step of calibrating AxoStep. Single Calibrate: Allows the user to perform a full calibration at current wavelength set on the Measurement Tab. Press Single Calibration to begin the calibration. Once the calibration is complete, a dialog showing the Root Mean Square (RMS) of the calibration will appear allowing the user to accept or reject the calibration. RMS less than 3% is acceptable. Spectral Calibration: Allows the user to perform a full calibration from 450 nm to 650 nm (default setting). The user can change the wavelength range and increment for calibration from Program Options on the Tools menu. Press Spectral Calibration to begin the calibration. Once the calibration is complete, a dialog showing the RMS of the spectral calibration will appear allowing the user to accept or reject the calibration. RMS less than 3% is acceptable at each wavelength. 20

25 Spectral Orientation: (Requires AxoStep Engine Version 1.9.0): Spectral orientation calibration, replaces the Ret-Zero buttons, and Ret-Zero Image buttons used in previous versions. When the Spectral Orientation button is pressed, the user will be prompted to place the Cal-Vis-1 in the sample holder (or the X-Y stage will move to the Cal-Vis-1 position). Next, and orientation calibration image is acquired at each of the wavelengths that are configured for the Spectral Calibration button. Light Source Calibration: Allows the user to calibrate wavelength offset for spectral light source. After the Light Source Calibration button is pressed, the Tunable Visible Source Calibration Utility will appear. The Calibration Utility provides a NIST-traceable technique for accurately calibrating the optical wavelength of the source to within +/-0.3 nm at the Holmium Oxide absorption line at nm. See AxoStep Tunable Visible Source Calibration Manual for the details BEFORE VERSION The following section describes the buttons on the calibration tab for versions of the AxoStep Viewer earlier than Version Dark Image: This is the same function as described in Section Single Calibrate: This is the same function as described in Section Spectral Calibration: This is the same function as described in Section

26 Baseline: This is the same function as described in Section Ret Zero: Allows the user to set Retardance Orientation to 0.00º. To change the AxoStep reference axis, a retarder (CAL-VIS-1) is placed in the sample compartment, and the AxoStep will find the corresponding retardance axis. This axis becomes the new zero angle from which all diattenuation orientations, retardance orientations, and the Poincaré sphere are defined. The Axometrics CAL-VIS-1 Retardance Orientation reference standard is a precision, true zero order quartz retardation plate laminated to a BK7 glass substrate. The CAL-VIS-1 is shipped with a calibration report that gives the angle between the mechanical edge of the mounting cell and the fast axis of the retarder. Ret Zero Image: Allows the user to perform Ret Zero orientation calibration pixel by pixel. Diatt Zero: Allows the user to set Diattenuation Orientation to 0.00º. To change the AxoStep reference axis, a polarizer (CAL-VIS-2) is placed in the sample compartment, and the AxoStep will find the corresponding diattenuation axis. This axis becomes the new zero angle from which all diattenuation orientations, retardance orientations, and the Poincaré sphere are defined. The Axometrics CAL-VIS-2 Diattenuation Orientation reference standard is a precision wire-grid polarizer laminated on an isotropic fused silica substrate. The CAL-VIS-2 is shipped with a calibration report that gives the angle between the mechanical edge of the mounting cell and the transmission axis of the polarizer Light Source Calibration: This is the same function as described in Section Polarimeter Coordinate System It is imperative that the user understands the coordinate system used by all the Axometrics polarimeters. This coordinate system is standard throughout most of the polarization measurement community. Coordinate system of the instrument with a tip-tilt stage is defined as follows: The reference edge on the stage defines X axis. The direction X axis is defined as zero degree of rotation angle. 22

27 The line from PSG head to PSA head defines the Z direction, as shown below. 23

28 2.9 Toolbars The tools in the Toolbars are shown below BASIC TOOLS 1. New project Remove all Mueller Matrix images and Date from memory and create a new project. 2. Open file Open *.bmmi, *.cmmi or *.astp files to view and analyze. 3. Save single measurement Save current image as *.cmmi file. 4. Save scan measurement Save current images as *.astp file. 5. Import calculated data Import calculated data to the viewer. 6. Export calculated data Export calculated data to *.cvs file that can be open by spreadsheet programs. 7. Show vectors Show the vectors that indicate the orientations of retardance, diattenuation, polarizance, etc MEASUREMENT INFORMATION Show the measurement information like following figure shown. 24

29 2.9.3 CROSS SECTION PLOTS Open a new window that shows a cross section of the data centered on the current cursor location. The user can select between an X cross section (horizontal), a Y Cross Section (vertical), a Z Cross section (through multiple images) or a line cross section. The Cross Section window is shown in the following figure. 25

30 allows the user to select between an X cross section (horizontal), a Y Cross Section (vertical), a Z Cross Section (through multiple images) and a Line Cross Section. Calculate Average: Calculate the average for X cross section (horizontal) and a Y Cross Section (vertical). For example, press Calculate Average when X cross section plot is chosen, the average value in the Y direction at every X position will be shown. The average of a selected area through multiple images can also be calculated by choosing Z Cross Section. Export: Export cross section data in a text file. Close: close Cross Sections window. 26

31 2.9.4 POINCARE SPHERE Show the selected data from Current Image or Scan Through Images on Poincare Sphere, as following figure shown. The user can use Picture Controls to select the area. Sphere Plot Type: allows the user to select between Current Image and Scan Through Images (through multiple images). Update: Update Poincare Sphere with new selected data. Close: close Poincare Sphere window D PLOT Show current image in a 3D plot as following figure shown 27

32 Plot Style: allows the user to select the plot style, Surface, Surface Line, Contour Line or Surface Contour. : allows the user to select the plot in a XY view or 3D view. Contour List: List the contour line values. 28

33 2.9.6 STATISTICS Show the statistic information of current image or selected area in a new window as following figure shown. Update: Update Statistic Window with a new current image or new selected area. Basic Parameters Tab: Show the basic statistic values of current image or selected area. Options Tab : Show Fit: allows the user to select if the fitting curve is shown or not. Order: The order of the fitting polynomial. Number of Bins: The number of pixel binning. 29

34 Remove Outliers: allow the user to remove the bad data. For example, the bad data results from dusts on the sample. Close: close Statistics window REDUCED PARAMETERS Show the reduced parameters at the current cursor position in a new window as the following figure shown. See APPENDIX (REDUCED PARAMETERS) for detailed information about these parameters EDGE DETECTION Find an edge in a selected area using Edge Detection Popup as following figure shown. Usually the found edge can be used as a reference position for user defined parameters. 30

35 2.9.9 OPTICAL GAUGING MEASUREMENT (Requires Optical gauging system to be installed) Press this button to perform a measurement with the Optical Gauging System. The result of the Optical Gauging measurement is shown on the bottom of the Calibration Tab The Alignment angle that is measured will be subtracted from the all orientation measurements IMAGE MEASUREMENTS Show the information about current cursor, straight line or selected area in the Measurements Popup as the following figure shown USER DEFINED CALCULATION Allow the user to define a function in a new window as the following figure shown. 31

36 The new data from User Defined Calculation can be shown in Current Image area by selecting User Defined Calculation on the Parameter To Plot list. For example, the user can define a new retardance orientation with respect to the features in images (default orientation is with respect to the AxoStep coordinate) using User Defined Calculation. To create a User Defined Calculation simply select New Calculation from the dropdown menu on the Calculations control then fill in the Name, calculation and variable definitions. This can be continued, allowing the user to create as many calculations as desired. The calculation that will be used by the viewer is the one selected, which has its name and definitions displayed. p LAUNCH AXOSTEP Pressing this button will launch the AxoStep Engine. If the AxoStep Engine is already running, pressing this button will establish a TCPIP connection with the AxoStep Engine, and update it s status in the viewer AUTO CALIBRATE Pressing this button will perform the User Defined Auto-Calibration routine. See Section for detailed Information. 32

37 LAUNCH TIP TILT CONTROLLER Launch the Tip Tile Controller window as the following figure shown. Note, Tip Tilt Controller program must be linked to AxoStep Viewer and the AxoStep Engine must be running to be able to use Tip Tile Controller. Move: Move to the orientation of the tilt and rotation angle set by the user. Save as Load Position: Save current position as load position. Exit: Exit Tip Tilt Controller window. Tilt Increment ( ): Set the tilt movement step. Tilt CCW: Make a tilt movement counterclockwise by one step. Tilt CW: Make a tilt movement clockwise by one step. Rotate Increment ( ): Set the rotate movement step. Rotate CCW: Make a rotate movement counterclockwise by one step. 33

38 Rotate CW: Make a rotate movement clockwise by one step LAUNCH X-Y CONTROLLER Launch the X-Y Controller window as the following figure shown. Note, X-Y Controller program must be linked to AxoStep Viewer and the AxoStep Engine must be running to be able to use X-Y Controller. 34

39 Move to Coordinates: Move to the position set by the user. Jog: Move table step by step. Move to Position: Move table to special positions, Scan Center, Load Position, Calibration in Air Position, CAL-VIS-1 Position, CAL-VIS-1 Position and Hole Plate Position. Current Settings: Show current settings for these special positions. Save Settings: Save current settings for these special positions. 35

40 Switch to Compact Mode: Change the X-Y Controller window to compact mode IMAGE THROUGH CROSSED POLARIZER Press this button to perform a calculation of the intensity of the measured samples as viewed through a set of polarizers at user defined orientations. When the button is pressed, the following dialog box appears. The user enters the orientation of the polarizer, and analyzer, and the software will calculate the image intensity for each MM image that is currently loaded into the viewer PITCH MEASUREMENT UTILITY This Button will launch the Pitch Measurement Utility (the path for the pitch measurement utility must be configured in the Program Options APPLY RETARDANCE ORDER Apply the algorithms developed by Axometrics to Unwrap the retardance order. Multiple Mueller Matrix Image datasets, acquired at different wavelengths are required to determine the retardance order values in the image. All Images must be properly registered to correctly calculate the retardance order. See Appendix 3.3, A Note about Retardance Order and Unwrapping, for detailed information about retardance order RTH CALCULATION Perform additional parameter calculations using multiple Mueller Matrix Image data sets that are stored in memory. The user can set the parameters for calculation in Rth Calculation Setup User Interface window as the following figure shown. 36

41 See Appendix 3.2, Calculated Parameters, for detailed information about Rth calculation LCD TOOLS Open LCDView to perform LCD parameter calculation. Note, in order to be able to use LCD Tools, the LCDView software must be installed and linked to AxoStep Viewer. See LCDView software manual for the details MAPPING SELECTION Because calculations performed on Mueller matrix image scans can be extremely time consuming, there are several options that can be used to perform the calculation on only a subset of the data. X Cross Section: performs the calculation only on an X cross section defined by the cursor location Y Cross Section: performs the calculation only on an Y cross section defined by the cursor location Selected Area (Map): performs a point by point calculation of the current area selected using the box tool 37

42 Selected Area (Avg): performs a single point calculation based on the average of the pixels within the area selected by the box tool. Full Image Map: Performs a complete calculation on the entire image dataset 2.10 Menu Bar FILE MENU The AxoStep Viewer File Menu has the following functions: NEW OPEN SAVE AS > SCAN FILE (*.astp) SAVE AS> PROCESSED IMAGE (*.CMMI) Clear all measurement information currently in memory Open a Mueller Matrix image dataset (*.cmmi, *.bmmi) or a scan dataset (*.astp) SAVE The current set of images as a new scan file (*..astp). All processing that was done on the scan (registration, etc) will be saved with this file. SAVE The current Mueller Matrix Images as a new *.cmmi. All image processing (eg, tilt and rotation correction) will be saved with this file. 38

43 IMPORT CALCULATED DATA EXPORT CALCULATED DATA EXPORT GRAPH EXIT Imports the calculated data on a *.csv spreadsheet file. Exports the calculated data to a *.csv spreadsheet file. Exports the data in the graph on the Data Tab to a *.csv spreadsheet file Shut down the AxoStep Viewer Program EDIT MENU functions: REMOVE IMAGE PROCESSING>TILT CORRECTION The AxoStep Viewer Edit Menu has the following Remove current image from memory. Open a new window as the following figure shown. The user can set a tilt angle to correct and press OK button to perform a tilt mapping at any desired angle. PROCESSING>ROTATION CORRECTION Open a new window as the following figure shown. The user can set a rotation angle to correct and press OK button to perform a rotation mapping at any desired angle. 39

44 Tilt and Rotation correction are used to reorient and map the pixels in the image to allow registration with images measured at different tilt and rotation settings. This only changes the location of the pixels in the image it does not change the orientation values of the data in the individual pixels. Normally tilt and rotation corrections have already been performed on *.cmmi files, however they will not have been performed on a *.bmmi file VIEW MENU The AxoStep Viewer View Menu has the following functions: REFRESH SHOW ORIENTATIONS INFO CROSS SECTIONS POINCARE SPHERE STATISTICS 3D PLOT Refresh current image. Functions the same as the Show Vectors Button on the Toolbar. Functions the same as the Measurement Information Button on the Toolbar. Functions the same as the Cross Section Plots Button on the Toolbar. Functions the same as the Poincare sphere Button on the Toolbar. Functions the same as the Statistics Button on the Toolbar. Functions the same as the 3D Plot Button on the Toolbar. 40

45 REDUCED PARAMETERS Functions the same as the Reduced Parameters Button on the Toolbar TOOLS MENU The AxoStep Viewer Tools Menu has the following functions: RECALCULATE>CURRENT IMAGE RECALCULATE>ALL IMAGES APPLY RETARDANCE ORDER EDGE DETECTION GEOMETRIC MEASUREMENT USER DEFINED OUTPUT RTH CALCULATION LCDVIEW CALCULATION PROGRAM OPTIONS Recalculate Calculated Parameter for current image. Recalculate Calculated Parameter for all images in memory. Functions the same as the Apply Retardance Order Button on the Toolbar. Functions the same as the Edge Detection Button on the Toolbar. Functions the same as the Image Measurement Button on the Toolbar. Functions the same as the User Defined Function Button on the Toolbar. Functions the same as the Rth Calculation Button on the Toolbar. Functions the same as the LCDView Button on the Toolbar. Open a new window that provides the user options to customize the AxoStep Viewer, as the following figure shown. 41

46 Display Options have the options as the above figure shown. Color Table: allows the user to change the color table for images. Invert Y axix: Invert the image in the Y direction. Display with correct aspect ratio: Displays the images with correct aspect ratio. Drawing color: Set the drawing color for Cursor, Box and Circle Tools. Drawing width: Set the drawing line width for Cursor, Box and Circle Tools. Show Axostep coordinate: Shows the X and Y axes on images with selected colors. Show Orientations: Show the vectors of orientations on images with selected density (Number of Lines), color and line width. Toolbar Options allow the user to show or hide buttons on the Toolbar, and allow the user to choose how the buttons to show (small or large icons). Poincare Sphere Options allow the user to customize Poincare Sphere. Cross Section Options allow the user to customize Cross Section Plots. 3D Plots Options allow the user to customize 3D Plots. 42

47 Analysis Options allow the user to customize image display, user interface and Edge Detection. Statistics Options allow the user to change some parameters for Statistics. Retardance Order Options allow the user to change some parameters for Retardance Order calculation. LCD Analysis Options allow the user to link LCDView program to AxoStep Viewer. Calibration Options allow the user to set some parameters for Calibration. AxoStep Engine Options allow the user to set IP address and Port for controlling AxoStep through AxoStep Viewer. Here, the user also can link XY Controller and Tip Tilt Controller programs to AxoStep Viewer HARDWARE MENU LAUNCH TIP TILT CONTROLLER LAUNCH XY CONTROLLER Functions the same as the Launch Tip Tilt Controller Button on the Toolbar. Functions the same as the Launch XY Controller Button on the Toolbar HELP MENU ABOUT Displays the version number of the AxoStep Viewer software you are running Special Notes on Testing Polarization Elements CAL-VIS-1 REFERENCE RETARDER Each AxoStep ships with a reference retarder labeled CAL-VIS-1. The CAL-VIS-1 is intended to be used to verify the long term calibration of the polarimeter. The axis of retardance to the reference edge is specified at 0.1º but is typically oriented to 0.025º. If you calibrate orientation using the CAL-VIS-1 the accuracy of all retardation orientation measurements (measurements of retardation films etc.) will be limited only by the repeatability of the AxoStep system. However the accuracy of diattenuation orientation measurements can have a higher absolute accuracy error. 43

48 CAL-VIS-2 REFERENCE POLARIZER A diattenuation reference labeled CAL-VIS-2 may be shipped with AxoStep. The polarizer has been precisely aligned so that its transmission axis is aligned to the mechanical edge of the mounting cell to within ±0.05. If you calibrate orientation using the CAL-VIS-2 the accuracy of all diattenuation orientation measurements (measurements of polarizer films) will be limited only by the repeatability of the AxoStep system. However the accuracy of retardance orientation measurements can have a higher absolute accuracy error. It is recommended that for most measurements, that the CAL-VIS-1 be used as an orientation reference standard. If however high accuracy (<0.1 ) measurements of polarizer axes are required, then the CAL- VIS-2 orientation reference standard should be used. 44

49 3 LCD PRODUCTION This is how you configure and LCD Production Recipe 3.1 Define a Pixel Press the Define Pixel Button on the Output Regions Tab. 45

50 Press the Live Image Button. Once you have a satisfactory image of the Pixel to analyze, unlatch the Live image button and drag a box around the Pixel you wish to define. Press Define Pixel, and the selected region will be duplicated in the Pixel Image Indicator Press Save Pixel button (Pixel definition must be saved) 46

51 If necessary, press the Test Button. centered on the test pixel. If everything is configured properly, an indicator mark will be Press OK. 3.2 Perform a Test Measurement Perform a test measurement in accordance with the instructions given in Section 2.5. Once the measurement is complete, Register the images in accordance with the instructions given in Section Define your output Regions After a test measurement has been completed Select Parameter to Plot = Transmittance and select the Current Image to have Polar=0 and Azimuth = Click on the Output Regions Tab, 47

52 2. If it is not checked, check the box Show Pixel Location. 3. Press the Find Pixel Button. 4. A target should appear in the center of the pixel on-screen. 48

53 5. Drag out a region of the Pixel to be analyzed. Note: If desired, you can select the entire pixel. 6. On the Output Regions Tab, click Add Region 7. Enter a name for the region. 8. Repeat steps 5-7 until all desired regions have been defined. It is recommended that the user Save the Region Definitions by clicking the Export Regions Button CONFIGURE THE OUTPUT REGIONS Once the regions have been defined, they must be configured for LCD analysis. 1. Click on the LCD Production Recipe Tab a. There is a similar Region Table on the LCD Production Tab. 2. Click on the first region to configure. 3. Press the LCDView Button. 49

54 4. The data from the first region will be imported into LCDView. 5. Fit the data using LCDView (see LCDView User s Manual for details). 6. Once the data is fit, Close LCDView 50

55 Notice that the Fitted LCD Parameters are now shown in the table. Repeat Steps 2-6 for each region. 3.4 Configure the Robots. Configuring the Robots for an LCD Production Recipe is described below. 1. Press the Configure Robots Button on the LCD Production Tab. x,y Coordinates: The list of positions on the panel that are measured. Tilt, Rotation Angles: The tilt and rotation angles that are measured at each point Wavelengths: The wavelengths used at each measurement When the Configure Robots Button is pressed on the front panel, the LCD Measurement Recipe Builder window opens, which allows the user to configure the measurement recipe. 51

56 The following sections describe the steps necessary to properly set up a measurement recipe 3.5 x,y Coordinates Setup The first tab on the LCD Measurement Recipe Builder allows the user to setup the x,y Coordinates that will be used for the measurement. The x-y coordinates can be expressed in one of two ways 52

57 1. Absolute coordinates: The values in the coordinate list are the actual position values of the x-y stage motors. 2. Panel coordinates (only available with Optical Guaging machine vision system): The values in the coordinate list are measured from the lower left alignment mark on the LCD panel being measured, and the x-axis is the line joining the two alignment marks on the panel. The measurement locations illustrated on the x-y coordinates tab shown above are drawn using the last successful panel alignment measurement. The actual motor location are adjusted accordingly each time an alignment measurement is performed. Therefore, even if the panel is repositioned in the panel holder, the same location on the panel is measured. The relationship between panel coordinates and absolute coordinates is illustrated below. offset y Panel Coordinates offset x Absolute (Stage) Coordinates The user has three options for setting up these coordinates. Load From File: The user can load a tab delimited file of x and y coordinates that will be imported into the table. Enter By Hand: If the user presses the Enter By Hand button, the following window appears, allowing the user to manually enter x,y Coordinates. 53

58 Wizard: If the user presses the Wizard button, the Map Setup Wizard window appears, allowing the user to easily configure the x,y coordinates The first step when using the Map Setup Wizard is to move the x,y table to the first measurement position on the panel by using the Jog controls or manually entering the Coordinates and pressing the Move 54

59 button, or by dragging the cursor in the window. Once the x,y table is in the correct position, press the button. Press the Button Once the first position has been set, the text above the button changes to Step 2 and the text on the button also changes indicating that the user move the x,y table to the opposite corner of the desired measurement area, which will correspond to the second position. Once the x,y table is in the second position, press the button. Press the Button Once both positions have been selected, the following control appears, allowing the user to set the number of points in the measurement. In the example shown below, the user has selected an array of 15 points by 13 points (195 total measurement positions) whose corners are defined by the two points previously selected by the user. The user can configure the points in Three different ways. Grid: Defines the set of points as a rectangular grid. Line: Defines the Points along a line between Point 1 and Point 2 Staggered: Creates a Staggered array of point of the form 55

60 Once the array of points is defined, the Accept button is enabled. Pressing the Accept button causes the software to calculate the array of measurement points, and puts those values in the table on the LCD Measurement Recipe Builder front panel DISCRETE HOLES Pressing the Discrete Holes button brings up a dialog box showing a regular array of measurement locations. The user can click and drag to select any arrangement of positions desired. If a Measurement Hole Plate was provided with the sample holder for the APM system, the positions of the Holes in this dialog will directly correspond to the hole centers in the attached Hole Plate. Note: When the user selects Panel Coordinates, the two alignment marks appear in the window, allowing the user an easy reference for navigating the panel. All the controls on the window are also converted to panel coordinates, except the cursor window, which always shows the absolute position of the motor stages. 3.6 Tilt, Rotation Angles The second tab on the LCD Measurement Recipe Builder allows the user to setup the tilt and rotation angles that will be used for the measurement. 56

61 When setting up the rotation angles, the user has three options: Arbitrary Tilt and Rotation Angles: The user can select this option, to enter an arbitrary array of tilt and rotation angles. The values can either be loaded from a file, or entered by hand. If the user presses the Wizard Button, the following window appears. This utility allows the user to enter polar angle scans along arbitrary rotation angles. The rotation angles can be entered manually, or the user can enter equally spaced rotation angles. 57

62 3.7 Wavelengths. The third tab on the LCD Measurement Recipe Builder allows the user to setup the wavelengths that will be used for the measurement. The polarimeter performs measurements at the wavelengths entered by the user. These wavelengths can be loaded from a file or entered by hand, using the following control. If the user presses the Wizard button, the following control appears, allowing the user to setup the wavelengths automatically. 58

63 3.8 Perform a Test Measurement Once the Production Recipe is configured, it is recommended that the user save the Recipe, by pressing the Export Production Recipe button on the LCD Production Recipe Tab. Finally the recipe can be executed by pressing the Test Production Recipe Button The following options are available when performing a Production Recipe. Perform AutoFocus: Checking this box will cause the Production Recipe to perform a complete autofocus before each Mueller Matrix Image is acquired. Note: Checking this box will significantly increase the measurement time required to complete the recipe. Log Data During Measurement: Checking this box will cause the production recipe to save each data results as it is acquired, rather than waiting until the measurement completes to save the entire dataset. Center Pixel (recommended): Checking this box will perform an auto-centering before each Mueller Matrix image is acquired. 59

64 Log Bad crt rms: Checking this box will save the raw data files (*.astp) whenever a pixel centering is not performed properly. Threshold: is the amount (as a fraction of 1) of the pixel that falls outside the user defined output region. Thus triggering a Log Bad crt rms (if checked). Log All Astp files: will log all of the raw data for the production measurement. Note: It is recommended that this option only be used as a troubleshooting aid, as the raw data generated when performing a production recipe will fill up the space on the hard disk quickly. When the production recipe starts, the following window will appear allowing the user to monitor the progress of the measurement The image in the upper right corner shows a live image from the AxoStep Head. Once all the measurements at a given X,Y coordinate are complete, and Analysis Monitor will appear showing the results of the Pixel Search Algorithm and the regions being analyzed. 60

65 Once the production measurement is complete, The user can save the data by clicking File>Save from the pull down menus 61

66 4 APPENDIX 4.1 Reduced Parameters The fundamental measurement made by the MMP is the raw Mueller Matrix. The Mueller matrix is a 4 x 4 matrix of real numbers that completely describes the polarization altering properties of a sample for a given light source, location, and incident angle. The Mueller Matrix is a powerful mathematical tool for researchers because it enables them to simulate the effect of a sample on any incident polarization state, and it also allows them to simulate the combined effect of several different samples in sequence. On the main screen of the MMP software, the raw Mueller matrix can be found on the GENERAL tab. While the Mueller Matrix is complete in its description of a sample s polarization altering properties, most people find it extremely difficult to extract useful information from its 16 numbers. As such, the Mueller Matrix Polarimeter calculates a wide varied of reduced parameters and displays these parameters on the various tabs and graphics representations on the front screen. Keep in mind that each of these reduced parameters was ultimately calculated directly from the Mueller matrix. We describe each of these reduced parameters below. Transmittance/Reflectance This value ranges from 0 to 1 and describes the fraction of light that left the PSG and ultimately reached the detector within the PSA. A value less than 1 indicates that a sample has prevented some light from reaching the PSA, either through absorption, reflection, or scattering. If the MMP is set up to measure a transmitted beam, this value is the transmittance. If the MMP has been set up to measure a beam reflected from a sample, this value is the reflectance. NOTE: Keep in mind that this value is the average transmittance of all possible incident polarization states, or stated another way, is the transmittance of an unpolarized input beam. Tmax is the transmittance (or reflectance) for the polarization state that has the maximum transmittance through the sample. The corresponding polarization state is frequently called the Diattenuation vector or the Input Transmission Axis. More information about the diattenuation vector can be found below in the description of the Diattenuation Tab. Tmin is the transmittance of the polarization state that has the minimum transmittance through the sample. This minimum-transmission polarization state will always be orthogonal to the maximum-transmission polarization state (diattenuation vector). As an example, if the maximumtransmission polarization state is horizontal, then the minimum-transmission polarization state is vertical. Depolarization Index (Dep) is a single parameter that attempts to describe whether light has been depolarized anywhere within the sample. Depolarization Index can be in the range 0 Dep 1, where Dep = 0 implies no depolarization whatsoever, and Dep = 1 implies a perfect depolarizer. The depolarization index of a Mueller matrix M is defined as 1 : 1 Polarimetry Chapter 22, in The Handbook of Optics, 2 nd Ed., Vol.2, (McGraw Hill, New York, 1995). 62

67 Dep ( M ) 1 m i, j 2 i, j 3 m m RETARDANCE Retardance is a polarization-dependent phase change associated with a sample. The phase (optical path length) of the output beam depends on the polarization state of the input beam. The transmitted phase is a maximum for one polarization state, and is a minimum for the orthogonal polarization state. Retardance is defined by two parameters, the Retardance Magnitude and the Fast Axis. The retardance magnitude varies from 0º to 180º. The retardance order is the additional integer number of half-wavelengths present. The AxoStep measuring at a single wavelength cannot distinguish between orders. Retarders with Identical Mueller Matrices Order δ, Retardance θ, Orientation 0 δ θ 1 360º - δ θ + 90º 2 360º + δ θ 3 720º - δ θ + 90º 4 360º + δ θ and so on If the retardance order is known, you can enter it into the Retardance Order control. If the SpectroPolarimeter option is installed, you can also measure the retardance order by pressing the Measure Retardance Order button. This function will measure the retardance at five different wavelengths (centered on the current wavelength) and attempt to determine the retardance order based on the spectral variation. NOTE If the retardance order is known to be higher than 3 rd or 4 th order, you should consider making a series of Spectral measurement at different wavelength increments to ensure that the correct order is measured. The Retardance Magnitude describes the difference in phase between the fastest and slowest polarization states. This phase difference can be expressed as an angle (in radians or degrees), or as a fraction of a wave (since there are 360 of phase in one wave, a quarter-wave retarder has 90 of retardance), or in units of length (typically in nm). Since a light path could be delayed for several half-wave plus a fraction of a half-wave through a sample, and only the delay of the fractional part makes a real difference on the polarization status for a single wavelength light, the retardance magnitude displayed by default is that fractional part, or in other words, the zero order. If the polarization properties are measured in a spectrum (The SpectroPolarimeter option must be installed to perform this measurement), the total retardance magnitude will be displayed by pressing MEASURE RETARDANCE ORDER. The number displayed in the Retardance Order indicates how much half-wave phase delay the total retardance contains. Retardance Order can be reset to zero by pressing RESET button, so that only the zero order retardance is displayed. The Fast Axis is the polarization state that passes through the sample the fastest. In a birefringent crystal, the Fast Axis is associated with the mode with the lower refractive index. The Fast Axis can be any polarization state: linear, elliptical, or circular. This fast axis is displayed graphically as a green dot 63

68 on the Poincaré sphere. For most single crystals the fast axis is a linear state on the equator of the Poincaré sphere. For combinations of crystals at arbitrary angles, the fast axis is generally elliptical and changes with wavelength. Alternately, we can describe the fast axis numerically by describing its Orientation (related to its longitude on the Poincaré sphere) and by the ratio of Linear Retardance and Circular Retardance present. The zero degree direction of Orientation is defined by default by the line scribed into the front window housing of the head and can be redefined as described in Section The linear and circular components of retardance are related to the total retardance magnitude by: mag 2 linear 2 circular In our retardance convention, the circular retardance component is negative to represent a fast-axis with a left-handed circular component and positive for right-handed circular components. Do not interpret the negative circular retardance to indicate that the retardance is actually negative. A common way that retardance can be introduced into a sample is through birefringence, or a difference in refractive index (n 1 n 2 ) for two different polarization states. The retardance is related to the birefringence through the equation: 360 n1 n2 t where t is the thickness of the sample, is the optical wavelength, and the retardance is expressed in degrees DIATTENUATION Diattenuation describes the difference in transmission between different input polarization states, and is defined as: Diat T max min. T max T T min Diattenuation can have values between zero and one, with Diat = 0 implying no difference in transmittance between various polarization states, and Diat = 1 imply total attenuation (through absorption or reflection) of one polarization state as in a perfect polarizer. Similar to retardance, the diattenuation is described by a Diattenuation Magnitude and a Transmission Axis (called the Diattenuation Vector). This axis defines the polarization state that is maximally transmitted, and is displayed graphically on the Poincaré sphere as a blue dot. Note that the minimally transmitted polarization will always be the orthogonal polarization state. The diattenuation vector is displayed numerically on the Diattenuation Tab by its Orientation, and its Linear and Circular components. As with the retardance fast-axis, we allow negative circular diattenuation to be a description of positive diattenuation with a left-hand-circular component. Diattenuation is also commonly called the Polarization Dependent Loss or PDL, and is shown this way on the Diattenuation Tab expressed in db. 64

69 Another equivalent description of diattenuation is the extinction ratio. This parameter is not displayed on the Diattenuation Tab in this version of the software, but can be easily calculated as: T E T min max 1 Diat 1 Diat The Diattenuation Tab also describes the Polarizance of the sample. The Polarizance is defined as the degree of polarization (DOP) of the transmitted light when unpolarized light is incident on the sample. As with the retardance and diattenuation, polarizance is defined by a Polarizance Magnitude and the Polarizance Vector. The polarizance magnitude is the DOP of transmitted light when unpolarized light is incident. The polarizance vector describes this output polarization state, and is shown graphically on the Poincaré sphere as a red dot. The polarizance vector is described numerically on the Diattenuation Tab by its Orientation, and its Linear and Circular components. It is interesting to note that the diattenuation magnitude and polarizance magnitude will be exactly the same if there are no depolarization effects whatsoever in the sample. Conversely, if the diattenuation magnitude and polarizance magnitude are different in a sample, it always implies a depolarization effect. As a trivial example, consider a perfect polarizer followed by a perfect depolarizer. This system will have a diattenuation of 1 but a polarizance of 0 (the output DOP is zero due to the depolarizer). 4.2 Calculated Parameters The above screen shows the results of a two-axis retardance measurements. By default, retardance in nm versus incident angle is plotted. To the right, a table of calculated parameters is given. These parameters are calculated individually for tilt about both axes and the average value is also presented (unless a one-axis measurement was performed). The definitions of these parameters follows: R0 Retardance at normal incidence, governed by the formula R0 = (Nx Ny) d where d is the sample thickness and Nx and Ny are the refractive indices in the plane of the sample. (Z is defined as the direction of light propagation, normal to the surface of the sample). R0 can either me directly determined from the on-axis measurement, or it can be determined from the curve-fit to the measured angular data. Use the CALCULATE R0 FROM CURVE FIT checkbox to select your preferred calculation mode. Axometrics generally recommends not using the curve-fit to calculate unless the measurement data is very noisy due to low retardance or fringing from a laser light source. Rth An industry-standard term used to describe the off-axis retardance variation of a sample. Axometrics lets the user choose the desired Rth equation from the CALCULATIONS tab: 65

70 (1) Axometrics has seen a wide range of Rth equations in use in the industry. The equation shown above appears to be the most widely used. However it is important for the user to know which equation is typically used in their application. (2) Another important note about the Rth parameter is that it does not uniquely define the retardance vs. angle characteristic of a sample. Two samples with different thickness but the same Rth values will have different retardance vs. incident angle curves. (3) Rth must be calculated from a fairly complicated curve fit. In the analysis screen, the results of the curve fit are displayed with the retardance data points whenever retardance (nm) is the parameter being shown on screen. In order to perform this curve fit, the user must enter assumed values of the sample thickness and average in-plane refractive index. These values are entered in the Navg and d (µm) controls at the top of the analysis screen. There may be instances when the curve fit clearly does not accurately follow the measured data. In these cases, you cannot trust the regressed value of Rth. β Tilt angle of the refractive index ellipsoid with respect to the XY plane of the sample. The following figure illustrates these values: 66

SPECTRAL IMAGING VIEWER SOFTWARE MANUAL

SPECTRAL IMAGING VIEWER SOFTWARE MANUAL 103 Quality Circle, Suite 215 Huntsville, AL 35806 Phone: (256) 704-3332 Fax: (256) 971-2073 E-Mail: info@axometrics.com Website: http://www.axometrics.com SPECTRAL IMAGING VIEWER SOFTWARE MANUAL 2012

More information

Axometrics, Inc. 103 Quality Circle, Suite 215 Huntsville, AL Phone: (256) Fax: (256)

Axometrics, Inc. 103 Quality Circle, Suite 215 Huntsville, AL Phone: (256) Fax: (256) Axometrics, Inc. 103 Quality Circle, Suite 215 Huntsville, AL 35806 Phone: (256) 704-3332 Fax: (256) 704-6002 E-Mail: info@axometrics.com Website: http://www.axometrics.com EllipsoView TM USER S MANUAL

More information

How to Measure Wedge. Purpose. Introduction. Tools Needed

How to Measure Wedge. Purpose. Introduction. Tools Needed Purpose Optical Wedge Application (OWA) is an add-on analysis tool for measurement of optical wedges in either transmission or reflection. OWA can measure a single part or many parts simultaneously (e.g.

More information

AxoScan TM Mueller Matrix Polarimeter

AxoScan TM Mueller Matrix Polarimeter 103 Quality Circle, Suite 215 Huntsville, AL 35806 Phone: (256) 704-3332 Fax: (256) 971-2073 E-Mail: info@axometrics.com Website: http://www.axometrics.com AxoScan TM Mueller Matrix Polarimeter OPERATOR

More information

Modify Panel. Flatten Tab

Modify Panel. Flatten Tab AFM Image Processing Most images will need some post acquisition processing. A typical procedure is to: i) modify the image by flattening, using a planefit, and possibly also a mask, ii) analyzing the

More information

User Guide 701P Wide Format Solution Wide Format Scan Service

User Guide 701P Wide Format Solution Wide Format Scan Service User Guide 701P44865 6204 Wide Format Solution Wide Format Scan Service Xerox Corporation Global Knowledge & Language Services 800 Phillips Road Bldg. 845-17S Webster, NY 14580 Copyright 2006 Xerox Corporation.

More information

CVI SPECTRAL PRODUCTS. 111 Highland Drive Putnam CT, (860) SM32Pro

CVI SPECTRAL PRODUCTS. 111 Highland Drive Putnam CT, (860) SM32Pro CVI SPECTRAL PRODUCTS 111 Highland Drive Putnam CT, 06260 (860) 928-5834 SM32Pro 2.8.28 Table of Contents Warranty and Liability 1 Quick Start Installation Guide 2 System Requirements 3 Requirements for

More information

Motic Images Plus 3.0 ML Software. Windows OS User Manual

Motic Images Plus 3.0 ML Software. Windows OS User Manual Motic Images Plus 3.0 ML Software Windows OS User Manual Motic Images Plus 3.0 ML Software Windows OS User Manual CONTENTS (Linked) Introduction 05 Menus and tools 05 File 06 New 06 Open 07 Save 07 Save

More information

LEXT 3D Measuring LASER Microscope

LEXT 3D Measuring LASER Microscope LEXT 3D Measuring LASER Microscope Warning: This instrument may only be operated by those who have been trained by AAF staff and have read and signed the AAF laboratory policies. A) STARTUP 1. Computer

More information

SAS Visual Analytics 8.2: Working with Report Content

SAS Visual Analytics 8.2: Working with Report Content SAS Visual Analytics 8.2: Working with Report Content About Objects After selecting your data source and data items, add one or more objects to display the results. SAS Visual Analytics provides objects

More information

Galaxie Photodiode Array Software

Galaxie Photodiode Array Software Varian, Inc. 2700 Mitchell Drive Walnut Creek, CA 94598-1675/USA Galaxie Photodiode Array Software User s Guide Varian, Inc. 2002-2006 03-914950-00:6 Table of Contents Introduction... 3 General... 3 PDA

More information

Getting Started with DADiSP

Getting Started with DADiSP Section 1: Welcome to DADiSP Getting Started with DADiSP This guide is designed to introduce you to the DADiSP environment. It gives you the opportunity to build and manipulate your own sample Worksheets

More information

Process Eye Professional. Recall

Process Eye Professional. Recall Process Eye Professional Recall Process Eye Professional Recall User Manual SP104010.101 August 2005 As part of our continuous product improvement policy, we are always pleased to receive your comments

More information

Insight: Measurement Tool. User Guide

Insight: Measurement Tool. User Guide OMERO Beta v2.2: Measurement Tool User Guide - 1 - October 2007 Insight: Measurement Tool User Guide Open Microscopy Environment: http://www.openmicroscopy.org OMERO Beta v2.2: Measurement Tool User Guide

More information

XRADIA microxct Manual

XRADIA microxct Manual XRADIA microxct Manual Multiscale CT Lab Table of Contents 1. Introduction and Basics 1.1 Instrument Parts 1.2 Powering up the system 1.3 Preparing your sample 2. TXM Controller 2.1 Starting up 2.2 Finding

More information

2D Tutorial. Project Description: Running VisualAnalysis: Setting Up the Project:

2D Tutorial. Project Description: Running VisualAnalysis: Setting Up the Project: 2D Tutorial Project Description: This project has been set-up to demonstrate the basic features of VisualAnalysis. You will model and analyze the following two-dimensional frame with a curved glue-laminated

More information

Table of Contents. Logos Imaging Application User s Manual Version Page 1

Table of Contents. Logos Imaging Application User s Manual Version Page 1 Table of Contents About... 4 System Requirements... 5 Uninstall Previous Versions... 5 Install LIA 6.0... 6 Install the Device Drivers... 13 Register... 14 Getting Help... 14 Technical Support... 14 Workspace

More information

Instruction manual for T3DS calculator software. Analyzer for terahertz spectra and imaging data. Release 2.4

Instruction manual for T3DS calculator software. Analyzer for terahertz spectra and imaging data. Release 2.4 Instruction manual for T3DS calculator software Release 2.4 T3DS calculator v2.4 16/02/2018 www.batop.de1 Table of contents 0. Preliminary remarks...3 1. Analyzing material properties...4 1.1 Loading data...4

More information

Working with Charts Stratum.Viewer 6

Working with Charts Stratum.Viewer 6 Working with Charts Stratum.Viewer 6 Getting Started Tasks Additional Information Access to Charts Introduction to Charts Overview of Chart Types Quick Start - Adding a Chart to a View Create a Chart with

More information

WDM Phasar User s Guide

WDM Phasar User s Guide WDM Phasar User s Guide Phased Array WDM Device Design Software Version 2.0 for Windows WDM_Phasar User s Guide Phased Array WDM Device Design Software Copyright Opti wave Systems Inc. All rights reserved.

More information

StickFont Editor v1.01 User Manual. Copyright 2012 NCPlot Software LLC

StickFont Editor v1.01 User Manual. Copyright 2012 NCPlot Software LLC StickFont Editor v1.01 User Manual Copyright 2012 NCPlot Software LLC StickFont Editor Manual Table of Contents Welcome... 1 Registering StickFont Editor... 3 Getting Started... 5 Getting Started...

More information

FARO Scanning Plugin

FARO Scanning Plugin FARO Scanning Plugin For compatibility with Geomagic products, see Release Notes for. Document version E. Copyright 2005, Raindrop Geomagic, Inc. The FARO scanner is a seven-axis measurement device from

More information

Navigator Software User s Manual. User Manual. Navigator Software. Monarch Instrument Rev 0.98 May Page 1 of 17

Navigator Software User s Manual. User Manual. Navigator Software. Monarch Instrument Rev 0.98 May Page 1 of 17 User Manual Navigator Software Monarch Instrument Rev 0.98 May 2006 Page 1 of 17 Contents 1. NAVIGATOR SOFTWARE 2. INSTALLATION 3. USING NAVIGATOR SOFTWARE 3.1 STARTING THE PROGRAM 3.2 SYSTEM SET UP 3.3

More information

KCS Motion. Video Motion Analysis Software

KCS Motion. Video Motion Analysis Software Video Motion Analysis Software Software and supporting material is property of G. Mason, Seattle University, 2007 Overview Overview KCS Motion tracks moving objects in a video clip and analyzes their position,

More information

MESURgauge Software. User s Guide

MESURgauge Software. User s Guide MESURgauge Software User s Guide MESURgauge Software Thank you! Thank you for purchasing MESURgauge software, a data collection and analysis program developed to: Measure Collect data from digital force

More information

MESURgauge Software. User s Guide

MESURgauge Software. User s Guide MESURgauge Software User s Guide Thank you Thank you for purchasing MESURgauge software, a data collection and analysis program developed to: Measure Collect data from digital force gauges, torque gauges,

More information

Operating Procedure for Horiba Raman Microscope

Operating Procedure for Horiba Raman Microscope Operating Procedure for Horiba Raman Microscope SAFETY Be aware of Laser radiation at all times! Do not remove the covers of the instrument. Components are supplied with 110V electric source. Do not touch

More information

Quantifying Motion in Three Dimensions with ProAnalyst

Quantifying Motion in Three Dimensions with ProAnalyst Date Published: March 2007 Revised: April 2011 Abstract This tutorial provides users with a step-by-step guide to performing an analysis with ProAnalyst 3-D Professional Edition. This lesson covers the

More information

Data Handling and Reports

Data Handling and Reports Varian Analytical Instruments 2700 Mitchell Drive Walnut Creek, CA 94598-1675/USA Star Chromatography Workstation Version 6 Data Handling and Reports Tutorials Varian, Inc. 2002 03-914736-00:Rev. 4 Trademark

More information

TraceFinder Analysis Quick Reference Guide

TraceFinder Analysis Quick Reference Guide TraceFinder Analysis Quick Reference Guide This quick reference guide describes the Analysis mode tasks assigned to the Technician role in the Thermo TraceFinder 3.0 analytical software. For detailed descriptions

More information

Physics MRI Research Centre UNIFIT VERSION User s Guide

Physics MRI Research Centre UNIFIT VERSION User s Guide Physics MRI Research Centre UNIFIT VERSION 1.24 User s Guide Note: If an error occurs please quit UNIFIT and type:.reset in the IDL command line, and restart UNIFIT. Last Update November 2016 by Katie

More information

Agilent EZChrom Elite. PDA Analysis

Agilent EZChrom Elite. PDA Analysis Agilent EZChrom Elite PDA Analysis Notices Copyright Scientific Software, Inc 1997-2003 Agilent Technologies, Inc. 2006. No part of this manual may be reproduced in any form or by any means (including

More information

Beam Profilier - Beamage 3.0

Beam Profilier - Beamage 3.0 Profilier - age 3.0 KEY FEATURES High resolution (160x120 points) 2.2 MPixels resolution gives accurate profile measurements on very small beams Large Area The 11.3 x 6.0 mm sensor allows to measure very

More information

Committed to Quality. MicroLogPRO Solution. User Guide

Committed to Quality. MicroLogPRO Solution. User Guide Committed to Quality MicroLogPRO Solution User Guide MicroLogPRO & MicroLog Plus User Guide Third Edition First Print April 2007 Fourier Systems Ltd. Contents Using the Guide... 1 Compliance with FDA

More information

MicroLite & MicroLab Lite User Guide. First Edition First Print February 2007 Fourier Systems Ltd.

MicroLite & MicroLab Lite User Guide. First Edition First Print February 2007 Fourier Systems Ltd. MicroLite & MicroLab Lite User Guide First Edition First Print February 2007 Fourier Systems Ltd. Contents Introduction... 1 Chapter 1 Using the MicroLite... 2 1.1. Overview... 3 1.2. Getting Started...

More information

Perceptron Plugin. Activating the Perceptron Plugin

Perceptron Plugin. Activating the Perceptron Plugin Perceptron Scanner Plugin for compatibility with Geomagic products, see Release Notes for Geomagic Document version D. Copyright 2005, Raindrop Geomagic, Inc. Plugins > Perceptron is the interface in Geomagic

More information

Getting Started. In This Chapter

Getting Started. In This Chapter Getting Started In This Chapter 2 This chapter introduces concepts and procedures that help you get started with AutoCAD. You learn how to open, close, and manage your drawings. You also learn about the

More information

Lesson 1 Parametric Modeling Fundamentals

Lesson 1 Parametric Modeling Fundamentals 1-1 Lesson 1 Parametric Modeling Fundamentals Create Simple Parametric Models. Understand the Basic Parametric Modeling Process. Create and Profile Rough Sketches. Understand the "Shape before size" approach.

More information

Colony Counting User Manual A D I V I S I O N O F S Y N O P T I C S L T D

Colony Counting User Manual A D I V I S I O N O F S Y N O P T I C S L T D ProtoCOL Colony Counting User Manual S Y N B I O S I S A D I V I S I O N O F S Y N O P T I C S L T D All possible care has been taken in the preparation of this publication, but Synoptics Limited accepts

More information

SAS Visual Analytics 8.2: Getting Started with Reports

SAS Visual Analytics 8.2: Getting Started with Reports SAS Visual Analytics 8.2: Getting Started with Reports Introduction Reporting The SAS Visual Analytics tools give you everything you need to produce and distribute clear and compelling reports. SAS Visual

More information

Desktop Studio: Charts. Version: 7.3

Desktop Studio: Charts. Version: 7.3 Desktop Studio: Charts Version: 7.3 Copyright 2015 Intellicus Technologies This document and its content is copyrighted material of Intellicus Technologies. The content may not be copied or derived from,

More information

To Plot a Graph in Origin. Example: Number of Counts from a Geiger- Müller Tube as a Function of Supply Voltage

To Plot a Graph in Origin. Example: Number of Counts from a Geiger- Müller Tube as a Function of Supply Voltage To Plot a Graph in Origin Example: Number of Counts from a Geiger- Müller Tube as a Function of Supply Voltage 1 Digression on Error Bars What entity do you use for the magnitude of the error bars? Standard

More information

DwyerLog Logger Interface Software

DwyerLog Logger Interface Software DwyerLog Logger Interface Software USER S GUIDE Version 1.4x March 21, 2013 Dwyer Instruments, Inc 102 Indiana Hwy 212 Michigan City, IN 46360 Phone: (219) 879-8868 Fax: (219) 872-9057 http://www.dwyer-inst.com

More information

Sherlock 7 Technical Resource. Search Geometric

Sherlock 7 Technical Resource. Search Geometric Sherlock 7 Technical Resource DALSA Corp., Industrial Products (IPD) www.goipd.com 978.670.2002 (U.S.A.) Document Revision: September 24, 2007 Search Geometric Search utilities A common task in machine

More information

Chromatography Software Training Materials. Contents

Chromatography Software Training Materials. Contents Chromatography Software Training Materials This document contains information on how to build a method, start the instrument to acquire data, and then process the data using the Galaxie Program. You will

More information

Jasco FP-6500 Spectrofluorimeter Updated November 14, 2017

Jasco FP-6500 Spectrofluorimeter Updated November 14, 2017 Jasco FP-6500 Spectrofluorimeter Updated November 14, 2017 Instrument instructions can be found at: http://academic.bowdoin.edu/chemistry/resources/instructions.shtml If you have any problems with the

More information

Mu lt i s p e c t r a l

Mu lt i s p e c t r a l Viewing Angle Analyser Revolutionary system for full spectral and polarization measurement in the entire viewing angle EZContrastMS80 & EZContrastMS88 ADVANCED LIGHT ANALYSIS by Field iris Fourier plane

More information

Clinic Visual Evoked Response Imaging System Short User Manual

Clinic Visual Evoked Response Imaging System Short User Manual Clinic 6.0.9 EDI@veris-edi.com http://www.veris-edi.com Visual Evoked Response Imaging System Short User Manual Electro-Diagnostic Imaging, Inc. 200F Twin Dolphin Drive Redwood City, CA 94065-1402 2 Table

More information

TEL-218DRV TEL-X-Driver

TEL-218DRV TEL-X-Driver TEL-218DRV TEL-X-Driver TEL-Atomic, Incorporated P.O. Box 924 Jackson, MI 49204 1-800-622-2866 FAX 1-517-783-3213 email: telatomic@mindspring.com website: www.telatomic.com Features Angular Resolution:

More information

TOF-Watch SX Monitor

TOF-Watch SX Monitor TOF-Watch SX Monitor User manual Version 1.2 Organon (Ireland) Ltd. Drynam Road Swords Co. Dublin Ireland Contents General information... 3 Getting started... 3 File Window... 7 File Menu... 10 File Open

More information

LOREX Player User Manual Version 1.0

LOREX Player User Manual Version 1.0 LOREX Player User Manual Version 1.0 LOREX Player Manual - 1 - Table of Contents Introduction to LOREX Player... 3 LOREX Player Main View... 3 Video display area... 3 Application controls area... 4 LOREX

More information

SequencePro Data Analysis Application. User Guide

SequencePro Data Analysis Application. User Guide SequencePro Data Analysis Application User Guide SequencePro Data Analysis Application User Guide DRAFT October 31, 2001 12:52 pm, Title_page.fm Copyright 2001, Applied Biosystems. All rights reserved.

More information

User Manual Australia

User Manual Australia User Manual Australia April 2009 EAZ0057B06A Rev. A Trademarks Acknowledgements Snap-on, ShopStream Connect, ETHOS, MODIS, SOLUS, SOLUS PRO, and Vantage PRO are trademarks of Snap-on Incorporated. All

More information

Perkin-Elmer Lambda 3B Spectrophotometer

Perkin-Elmer Lambda 3B Spectrophotometer Written by Mark Csele Written by Jeff Brown Operation Turn on the Lambda 3B and the Computer Remove all samples from the sample chamber. Turn on the lamp for the range being investigated using the switches

More information

Desktop Studio: Charts

Desktop Studio: Charts Desktop Studio: Charts Intellicus Enterprise Reporting and BI Platform Intellicus Technologies info@intellicus.com www.intellicus.com Working with Charts i Copyright 2011 Intellicus Technologies This document

More information

Synoptics Limited reserves the right to make changes without notice both to this publication and to the product that it describes.

Synoptics Limited reserves the right to make changes without notice both to this publication and to the product that it describes. GeneTools Getting Started Although all possible care has been taken in the preparation of this publication, Synoptics Limited accepts no liability for any inaccuracies that may be found. Synoptics Limited

More information

VIEWZ 1.3 USER MANUAL

VIEWZ 1.3 USER MANUAL VIEWZ 1.3 USER MANUAL 2007-08 Zeus Numerix ViewZ 1.3.0 User Manual Revision: 200806061429 The latest copy of this PDF may be downloaded from the website. An online (HTML) version is also available. Zeus

More information

Quick Start Guide: Welcome to OceanView

Quick Start Guide: Welcome to OceanView Quick Start Guide: Welcome to OceanView Contents: Ctrl + Click a Topic Below for More Information Introduction to OceanView... 3 Welcome Screen... 3 Data Window... 3 Schematic View... 3 Persistence...

More information

Model FP-6500 Spectrofluorometer Instruction Manual. FP-6500 for Windows

Model FP-6500 Spectrofluorometer Instruction Manual. FP-6500 for Windows Model FP-6500 Spectrofluorometer Instruction Manual FP-6500 for Windows P/N: 0302-9999 April 2000 Contents Safety Considerations...i Regulatory Statements... iii Preface... iv Installation Conditions...v

More information

Software for Observation and Measurement SGMMS V2.6. Users Manual

Software for Observation and Measurement SGMMS V2.6. Users Manual AFM45-S03-12402 Software for Observation and Measurement SGMMS V2.6 Users Manual SIGMAKOKI Co., LTD. CONTENTS 1 OVERVIEW... - 3-2 BEFORE USE... - 3-2-1 OPERATIONAL ENVIRONMENT...- 3-2-2 INSTALLATION PREPARATION...-

More information

AEMLog Users Guide. Version 1.01

AEMLog Users Guide. Version 1.01 AEMLog Users Guide Version 1.01 INTRODUCTION...2 DOCUMENTATION...2 INSTALLING AEMLOG...4 AEMLOG QUICK REFERENCE...5 THE MAIN GRAPH SCREEN...5 MENU COMMANDS...6 File Menu...6 Graph Menu...7 Analysis Menu...8

More information

Multi Time Series Rev

Multi Time Series Rev Multi Time Series Rev. 4.0.12 The Multi Time Series program is designed to provide flexible programming of automated time dependent experiments. The basic programming unit is a single Time Series Block

More information

First Edition Termologger USB & OSAKA MicroLab Lite User guide

First Edition Termologger USB & OSAKA MicroLab Lite User guide First Edition Termologger USB & OSAKA MicroLab Lite User guide First Print February 2007 Introduction The Termologger USB is a compact 16-bit USB data logger designed for accurate temperature monitoring

More information

Using OPUS to Process Evolved Gas Data (8/12/15 edits highlighted)

Using OPUS to Process Evolved Gas Data (8/12/15 edits highlighted) Using OPUS to Process Evolved Gas Data (8/12/15 edits highlighted) Once FTIR data has been acquired for the gases evolved during your DSC/TGA run, you will process using the OPUS software package. Select

More information

SOFTWARE INSTRUCTIONS DIGITAL SPEAKER PROCESSOR DP-SP3

SOFTWARE INSTRUCTIONS DIGITAL SPEAKER PROCESSOR DP-SP3 SOFTWARE INSTRUCTIONS DIGITAL SPEAKER PROCESSOR DP-SP3 Thank you for purchasing TOA s Digital Speaker Processor. Please carefully follow the instructions in this manual to ensure long, trouble-free use

More information

Technical Documentation Version 7.3 Output

Technical Documentation Version 7.3 Output Technical Documentation Version 7.3 Output These documents are copyrighted by the Regents of the University of Colorado. No part of this document may be reproduced, stored in a retrieval system, or transmitted

More information

3DReshaper Help DReshaper Beginner's Guide. Surveying

3DReshaper Help DReshaper Beginner's Guide. Surveying 3DReshaper Beginner's Guide Surveying 1 of 29 Cross sections Exercise: Tunnel analysis Surface analysis Exercise: Complete analysis of a concrete floor Surveying extraction Exercise: Automatic extraction

More information

Prism Starter Guide 1.0 Hoskins Lab Last Modified 03/14/2017 Chris DeCiantis

Prism Starter Guide 1.0 Hoskins Lab Last Modified 03/14/2017 Chris DeCiantis Start Up: Upon entering the laser room turn on the wall mounted Laser Power Button by pulling it away from the wall. Turn on Shutter controllers (toggle switch on back of unit). There should be a U in

More information

Contents. Preparation for Software Installation Recommended Configuration Installing Motic Images Plus 2.0 Mac OS X...

Contents. Preparation for Software Installation Recommended Configuration Installing Motic Images Plus 2.0 Mac OS X... Contents Preparation for Software Installation... 1 Recommended Configuration... 1 Installing... 1 Precise Calibration... 2 The Menus... 3 File Menu...3 Edit Menu...6 View Menu...6 Image Menu...7 Paint

More information

Gallios TM Quick Reference

Gallios TM Quick Reference Gallios TM Quick Reference Purpose: The purpose of this Quick Reference is to provide a simple step by step outline of the information needed to perform various tasks on the system. We begin with basic

More information

newfasant US User Guide

newfasant US User Guide newfasant US User Guide Software Version: 6.2.10 Date: April 15, 2018 Index 1. FILE MENU 2. EDIT MENU 3. VIEW MENU 4. GEOMETRY MENU 5. MATERIALS MENU 6. SIMULATION MENU 6.1. PARAMETERS 6.2. DOPPLER 7.

More information

ezimagex2 User s Guide Version 1.0

ezimagex2 User s Guide Version 1.0 ezimagex2 User s Guide Version 1.0 Copyright and Trademark Information The products described in this document are copyrighted works of AVEN, Inc. 2015 AVEN, Inc. 4595 Platt Rd Ann Arbor, MI 48108 All

More information

Contents. CRITERION Vantage 3 Analysis Training Manual. Introduction 1. Basic Functionality of CRITERION Analysis 5. Charts and Reports 17

Contents. CRITERION Vantage 3 Analysis Training Manual. Introduction 1. Basic Functionality of CRITERION Analysis 5. Charts and Reports 17 CRITERION Vantage 3 Analysis Training Manual Contents Introduction 1 Basic Functionality of CRITERION Analysis 5 Charts and Reports 17 Preferences and Defaults 53 2 Contents 1 Introduction 4 Application

More information

Pre-Lab Excel Problem

Pre-Lab Excel Problem Pre-Lab Excel Problem Read and follow the instructions carefully! Below you are given a problem which you are to solve using Excel. If you have not used the Excel spreadsheet a limited tutorial is given

More information

Multivariate Calibration Quick Guide

Multivariate Calibration Quick Guide Last Updated: 06.06.2007 Table Of Contents 1. HOW TO CREATE CALIBRATION MODELS...1 1.1. Introduction into Multivariate Calibration Modelling... 1 1.1.1. Preparing Data... 1 1.2. Step 1: Calibration Wizard

More information

TempLog & RH/TempLog User Guide. Sixth Edition First print Printed in July

TempLog & RH/TempLog User Guide. Sixth Edition First print Printed in July TempLog & RH/TempLog User Guide Sixth Edition First print Printed in July 2003 www.4oakton.com Contents Using the Guide... 15 Chapter 1 OaktonLog... 17 1.1. Overview... 18 1.2. Getting Started... 19 1.3.

More information

Appendix E: Software

Appendix E: Software Appendix E: Software Video Analysis of Motion Analyzing pictures (movies or videos) is a powerful tool for understanding how objects move. Like most forms of data, video is most easily analyzed using a

More information

TotalLab TL100 Quick Start

TotalLab TL100 Quick Start TotalLab TL100 Quick Start Contents of thetl100 Quick Start Introduction to TL100 and Installation Instructions The Control Centre Getting Started The TL100 Interface 1D Gel Analysis Array Analysis Colony

More information

EMBO Practical Course on Image Processing for Cryo EM 1-11 September 2015

EMBO Practical Course on Image Processing for Cryo EM 1-11 September 2015 EMBO Practical Course on Image Processing for Cryo EM 1-11 September 2015 Practical 4: Optional part for experienced IMOD users - Reconstructing a cryo tomogram and sub-tomogram averaging of GroEL IMOD

More information

WATER MAZE VIDEO TRACKING

WATER MAZE VIDEO TRACKING instrumentation and software for research SOF-845 USER S MANUAL DOC-214 Rev. 2.2 Copyright 2016 All Rights Reserved Med Associates Inc. P.O. Box 319 St. Albans, Vermont 05478 Phone: 802.527.2343 Fax: 802.527.5095

More information

AEMLog users guide V User Guide - Advanced Engine Management 2205 West 126 th st Hawthorne CA,

AEMLog users guide V User Guide - Advanced Engine Management 2205 West 126 th st Hawthorne CA, AEMLog users guide V 1.00 User Guide - Advanced Engine Management 2205 West 126 th st Hawthorne CA, 90250 310-484-2322 INTRODUCTION...2 DOCUMENTATION...2 INSTALLING AEMLOG...4 TRANSFERRING DATA TO AND

More information

Tutorial 3: Using the Waveform Viewer Introduces the basics of using the waveform viewer. Read Tutorial SIMPLIS Tutorials SIMPLIS provide a range of t

Tutorial 3: Using the Waveform Viewer Introduces the basics of using the waveform viewer. Read Tutorial SIMPLIS Tutorials SIMPLIS provide a range of t Tutorials Introductory Tutorials These tutorials are designed to give new users a basic understanding of how to use SIMetrix and SIMetrix/SIMPLIS. Tutorial 1: Getting Started Guides you through getting

More information

Kulite DAQ. Data Acquisition Software User s Manual. Version 3.2.0

Kulite DAQ. Data Acquisition Software User s Manual. Version 3.2.0 Kulite DAQ Data Acquisition Software User s Manual Version 3.2.0 Table of Contents Kulite DAQ Overview... 3 Main Window... 4 1. Menu bar... 4 2. Interface selection... 5 3. Found devices... 5 4. Sorting...

More information

PART I GravoStyle5-Laser Introduction

PART I GravoStyle5-Laser Introduction PART I GravoStyle5-Laser Introduction I. INTRO GravoStyle 5 Laser is designed is a component of GravoStyle5 for use with the Gravograph/New Hermes and other manufacturer Laser Engravers. Combined with

More information

DataPro Quick Start Guide

DataPro Quick Start Guide DataPro Quick Start Guide Introduction The DataPro application provides the user with the ability to download and analyze data acquired using the ULTRA-LITE PRO range of Auto Meter products. Please see

More information

Living Image Software

Living Image Software Living Image Software User s Manual Version 3.1 2002-2008 Xenogen Corporation. All rights reserved. PN 124908 Xenogen Corporation 68 Elm Street Hopkinton, MA 01748 USA 1.877.522.2447 (US) 1.508.435.9500

More information

Determination of Drag Coefficient

Determination of Drag Coefficient DEPARTMENT OF MECHANICAL, INDUSTRIAL AND MANUFACTURING ENGINEERING MIMU 505 - MEASUREMENT AND ANALYSIS Determination of Drag Coefficient You will need to bring a zip disk or USB storage device to the lab

More information

FactoryLink 7. Version 7.0. Client Builder Reference Manual

FactoryLink 7. Version 7.0. Client Builder Reference Manual FactoryLink 7 Version 7.0 Client Builder Reference Manual Copyright 2000 United States Data Corporation. All rights reserved. NOTICE: The information contained in this document (and other media provided

More information

Selective Space Structures Manual

Selective Space Structures Manual Selective Space Structures Manual February 2017 CONTENTS 1 Contents 1 Overview and Concept 4 1.1 General Concept........................... 4 1.2 Modules................................ 6 2 The 3S Generator

More information

V-600 Operation. JASCO V-600 for Windows Software Manual

V-600 Operation. JASCO V-600 for Windows Software Manual V-600 Operation JASCO V-600 for Windows Software Manual P/N:0302-7420A September 2006 Preface This instruction manual serves as a guide for using this instrument. It is intended to instruct first-time

More information

Press the Plus + key to zoom in. Press the Minus - key to zoom out. Scroll the mouse wheel away from you to zoom in; towards you to zoom out.

Press the Plus + key to zoom in. Press the Minus - key to zoom out. Scroll the mouse wheel away from you to zoom in; towards you to zoom out. Navigate Around the Map Interactive maps provide many choices for displaying information, searching for more details, and moving around the map. Most navigation uses the mouse, but at times you may also

More information

Points Lines Connected points X-Y Scatter. X-Y Matrix Star Plot Histogram Box Plot. Bar Group Bar Stacked H-Bar Grouped H-Bar Stacked

Points Lines Connected points X-Y Scatter. X-Y Matrix Star Plot Histogram Box Plot. Bar Group Bar Stacked H-Bar Grouped H-Bar Stacked Plotting Menu: QCExpert Plotting Module graphs offers various tools for visualization of uni- and multivariate data. Settings and options in different types of graphs allow for modifications and customizations

More information

Standard Operating Manual

Standard Operating Manual Standard Operating Manual J.A. Woolam M-2000V Spectroscopic Ellipsometer Version 1.0 Page 1 of 13 Contents 1. Picture and Location 2. Process Capabilities 2.1 Cleanliness Standard 2.2 Features 2.3 Sample

More information

ME 365 EXPERIMENT 3 INTRODUCTION TO LABVIEW

ME 365 EXPERIMENT 3 INTRODUCTION TO LABVIEW ME 365 EXPERIMENT 3 INTRODUCTION TO LABVIEW Objectives: The goal of this exercise is to introduce the Laboratory Virtual Instrument Engineering Workbench, or LabVIEW software. LabVIEW is the primary software

More information

Microsoft Excel 2007

Microsoft Excel 2007 Microsoft Excel 2007 1 Excel is Microsoft s Spreadsheet program. Spreadsheets are often used as a method of displaying and manipulating groups of data in an effective manner. It was originally created

More information

FARO Scanning Plugin

FARO Scanning Plugin FARO Scanning Plugin for Geomagic Studio 6 service release 4, Geomagic Qualify 6 service release 2, and Geomagic Qualify 7 Document version B Copyright 2004, Raindrop Geomagic, Inc. The FARO scanner is

More information

form are graphed in Cartesian coordinates, and are graphed in Cartesian coordinates.

form are graphed in Cartesian coordinates, and are graphed in Cartesian coordinates. Plot 3D Introduction Plot 3D graphs objects in three dimensions. It has five basic modes: 1. Cartesian mode, where surfaces defined by equations of the form are graphed in Cartesian coordinates, 2. cylindrical

More information

v SMS 12.2 Tutorial Observation Prerequisites Requirements Time minutes

v SMS 12.2 Tutorial Observation Prerequisites Requirements Time minutes v. 12.2 SMS 12.2 Tutorial Observation Objectives This tutorial will give an overview of using the observation coverage in SMS. Observation points will be created to measure the numerical analysis with

More information

Perceptron Scan Plugin 7.0

Perceptron Scan Plugin 7.0 Perceptron Scan Plugin 7.0 For compatibility with Geomagic products, see Release Notes for Geomagic Perceptron Plugin 7.0. Copyright 2004, Raindrop Geomagic, Inc. Plugins > Perceptron is the interface

More information

User s Guide to the LMD Laser Micro-dissection. System

User s Guide to the LMD Laser Micro-dissection. System User s Guide to the LMD-6000 Laser Micro-dissection System Page 1 Glen MacDonald October 31, 2018 Start-up Procedure for Leica LMD-6000. 1. Turn on mercury lamp by pressing the rocker switch; a. beige

More information