Zeiss VisuMax/MEL for LASIK and Keratoplasty. William W. Culbertson, MD; Bascom Palmer Eye Institute, Miami, FL

Size: px
Start display at page:

Download "Zeiss VisuMax/MEL for LASIK and Keratoplasty. William W. Culbertson, MD; Bascom Palmer Eye Institute, Miami, FL"

Transcription

1 Zeiss VisuMax/MEL for LASIK and Keratoplasty William W. Culbertson, MD; Bascom Palmer Eye Institute, Miami, FL 1

2 VisuMax Femtosecond Laser Precision Low IOP Low energy Gentle on patient Minimal applanation SMILE LASIK flaps Keratoplasty ICR 2

3 Femtosecond Technology Spherical contact interface to cornea Corneal fixation assures a better fixation than scleral fixation designs Precise treatment positioning Different sizes to adapt to individual cornea dimension Low suction pressure Minimal applanation Minimal IOP increase No vision loss during suction* Page 3

4 VisuMax Femtosecond System Features of Visumax Flap: Predictable and accurate flap thickness (80 µm 220 µm) and dimension Flap bed parallel to corneal surface (Diameter 10.7 mm, applanated) Step side cut angle (selectable between 45 degree to 135 degree) Better fit for flap repositioning Increased safety

5 VisuMax Femtosecond System OCT flap imaging Homogeneous flap thickness Regular interface Visante OCT HD OCT

6 History of the Zeiss excimer laser 1986 MEL 50 introduced Zeiss has been in the refractive laser business for 27+ years 1989 MEL MEL MEL International launch of MEL

7 MEL-80 MEL-80 Excimer laser Smart Pulse technology Developed to control every laser pulse at high speed repetition rate (250Hz) Peripheral Pulse Control to compensate for energy reflection Very small spot size (0.7mm) Gaussian Beam Profile Closed Loop Controlled Energy Beam Delivery System Active Eye Tracking (1060 Hz) Optics Shielded and Vacuum Flushed 110V Page 7

8 MEL 80 Best FDA clinical results (August 2006) 93% 20/20 41% 20/15 Myopic approval -7D sphere Hyperopic approval +5D sphere Astigmatism approval 3D cylinder MRSE -8 D We can treat 95% of population base with current approvals Page 8

9 MEL 90 Excimer Technology The MEL 90 is the only flying spot excimer laser that builds on a legacy of 10 years of technical experience and excellent clinical outcomes The reliability of MEL 80 + the high clinical performance = MEL 90 Fastest intraoperative ablation on the market with its 500 Hz capability Carl Zeiss Meditec, Inc., Amy Wong, MarComm 8/6/2014 9

10 POWER, ACCURACY, TIME MEL 90 power With its unique FLEXIQUENCE switch function (250 Hz and 500 Hz operation) and additional configuration options the MEL 90 is a true customized power package. (FLEXIQUENCE - Frequency switch function 250 Hz/ 500 Hz) MEL 90 accuracy The Triple-A profile enables fast, safe and highly precise treatments. Its excellent predictability, even with astigmatism and higher ametropias, offers additional safety. (Triple-A Advanced Ablation Algorithm) MEL 90 time When performing LASIK for myopia at 500 Hz, MEL 90 can intra-operatively ablate 1 diopter as little as 1.3 seconds. Intuitive system guidance and speedy treatment planning allow for additional time savings. (Intra-operative speed of 1.3 seconds per diopter (Myopia, LASIK, 500 Hz, OZ: 6 mm)) Carl Zeiss Meditec, Inc., Amy Wong, MarComm 8/6/

11 INTELLIGENCE, ATMOSPHERE, OUTCOMES MEL 90 intelligence The Triple-A profile is based on an intelligent combination of refractive correction and clever energy distribution. It enables an aspherically optimized design with minimal ablation depth. As a result, treatments are faster and save tissue. MEL 90 atmosphere The unique, sensor-controlled CCA+ plume removal system supports optimal atmospheric conditions around the patient s eye thereby also significantly improving the predictability of the results.. MEL 90 outcomes The MEL 90 can be precisely tailored to the individual needs of the modern refractive surgical practice. Its preinstalled functions also offer surgeons optimal support for achieving excellent treatment results. Carl Zeiss Meditec, Inc., Amy Wong, MarComm 8/6/

12 Combination with VisuMax Fastest excimer-femtosecond combo on the market Real time bilateral femto-lasik using VisuMax and MEL: 8:30 minutes No platform extension required 90 and 180 setup Seamless data transfer Carl Zeiss Meditec, Inc., Amy Wong, MarComm 8/6/

13 Clinical Trial Results for MEL 90 Highly accurate and predictable outcomes for all ranges 13

14 LASIK with Visumax with MEL - 80

15 VisuMax Keratoplasty

16 VisuMax Femtosecond System Keratoplasty range of clinical applications Surgical procedures PTK ALK DLK PKP PLK Phototherapeutic Keratomileusis (excimer laser domain) Anterior Lamellar Keratoplasty Deep (Anterior) Lamellar Keratoplasty Penetrating Keratoplasty Posterior Lamellar Keratoplasty DSEK Descemet Stripping Endothelial Keratoplasty DALK

17 Corneal Structure vs Bubble Formation The upper layer collagen is denser, thinner and more compact The lower layer collagen is less dense, thicker and less compact

18 Corneal Structure vs Bubble Formation 100um Thickness 200um Thickness 300um Thickness 450um Thickness

19 Recommended Energy Setting for Keratoplasty ALK & DALK (Transparent Cornea) 100um Thickness: 110nJ-130nJ (3.0/3.0/1.5) 200um Thickness: 130nJ-150nJ (3.0/3.0/1.5) 300um Thickness: 200nJ-230nJ (1.6/1.6/1.5) 400um Thickness: 230nJ-280nJ (1.6/1.6/1.5) PKP Standard Mode: 280nJ - 300nJ (1.5/1.5) Fast Mode: 320nJ - 340nJ (2.0/2.0)

20

21 Circumferential deep folds caused by applanation

22 Engagement/Attachment: Intralase

23 Engagement/Attachment: FS - 200

24 Engagement/Attachment: Visumax Cross section of the contact glass

25 Interface and Transparency Outcomes

26 VisuMax Femtosecond System User programmable parameters for Keratoplasty Lamellar intrastromal cut parallel to the anterior surface of the cornea Lamellar incisions ranging from 50 µm up to 650 µm depth for anterior lamellar keratoplasty PKP: Penetrating Keratoplasty (sidecut) Max. appro 700 8mm Diameter range: mm Straight sidecut with adjustable sidecut angle Individual programming of all treatment parameters for donor and recipient treatment

27 VisuMax Femtosecond System Keratoplasty treatment planning user interface

28 VisuMax Femtosecond System Donor cornea handling easy and flexible solution Adapter to headrest of patient bed Cover plate can be sterilized

29 VisuMax Femtosecond System Corneal interface designed donor cornea preparation Donor cornea Special KP treatment pack No suction ring Designed to avoid mechanical interference with most artificial anterior chambers models Patient eye Regular Treatment Pack as used for flap (S/M/L) Artificial anterior chamber Dynamic pressure control -BSS Model Barron (katena, inc) is recommended

30 VisuMax Femtosecond System Impressions on clinical performance VisuMax workstation setup in sterile OR VisuMax microscope for manual surgery and suturing

31 VisuMax Femtosecond System Keratoplasty treatment planning user interface PKP (Donor & Receipient) Donor Curvature: 7.7mm (default) Receipient: individual K reading Donor Diameter > Receipient (+0.2mm) Actual Diameter = Nominal (+ 0.4mm) Outer diameter > Inner diameter (1mm) Side cut angle: 90 (less astigmatism) Cornea should be transparent Thickness > pachy approx micron Donor uses KP treatment pack Receipent uses normal treatment pack

32 VisuMax Femtosecond System Sidecut angle of PKP

33 VisuMax Femtosecond System Example Penetrating KP Separation and removal of donor button

34 VisuMax Femtosecond System Example Deep anterior lamellar KP 480 µm deep lamellar incision in the course of DALK

35 VisuMax Femtosecond System Visante OCT scans post-op DALK ant. lam. KP DSEK post. lam. KP

36 VisuMax Femtosecond System Histology of femtosecond incision Penetrating graft Incision depth: 715 µm Laser settings: 360 / 1.8 Incision time: 48 sec. Deep lamellar graft Incision depth: 450 µm Laser settings: 340 / 1.8 Incision time: 97 sec.

37 ALK with Visumax Anterior scar 6 months post infectious keratitis Pre-op Vision: 20/200

38 ALK Visumax

39 ALK with Visumax Anterior scar 6 months post infectious keratitis Post-op Vision: 20/40 sc

40 Zeiss VisuMax/MEL for LASIK and Keratoplasty

LASIK experience with the FS200 femto and EX500 excimer (the Refractive Suite)

LASIK experience with the FS200 femto and EX500 excimer (the Refractive Suite) LASIK experience with the FS200 femto and EX500 excimer (the Refractive Suite) A. John Kanellopoulos, MD Clinical Professor of Ophthalmology, NYU, New York, USA Medical Director, Laservision.gr Institute,

More information

UNIQUE FEMTOSECOND TECHNOLOGY

UNIQUE FEMTOSECOND TECHNOLOGY TECHNOLOGY BOOKLET UNIQUE FEMTOSECOND TECHNOLOGY The FEMTO LDV is a femtosecond laser which uses an oscillator as a laser source with high frequency output. As a consequence, it is not sensitive to environmental

More information

The new IOLMaster 700 Next generation biometry from ZEISS. With SWEPT Source Biometry

The new IOLMaster 700 Next generation biometry from ZEISS. With SWEPT Source Biometry The new IOLMaster 700 Next generation biometry from ZEISS With SWEPT Source Biometry The moment you get the full picture to make the best decisions for your patients. This is the moment we work for. //

More information

Scheimpflug topographical changes after Femtosecond LASIK for mixed astigmatism theoretical aspects and case study

Scheimpflug topographical changes after Femtosecond LASIK for mixed astigmatism theoretical aspects and case study Romanian Journal of Ophthalmology, Volume 61, Issue 1, January-March 2017. pp:69-75 CASE REPORT Scheimpflug topographical changes after Femtosecond LASIK for mixed astigmatism theoretical aspects and case

More information

Biometry in the post refractive surgery patient

Biometry in the post refractive surgery patient Biometry in the post refractive surgery patient The Frontiers of Cataract Surgery Royal Society of Medicine 8 th October 2015 Ali A. Mearza FRCOphth Consultant Ophthalmic Surgeon Imperial College Healthcare

More information

NEW. The new IOLMaster 500 from ZEISS Defining biometry. Markerless Toric IOL Alignment

NEW. The new IOLMaster 500 from ZEISS Defining biometry. Markerless Toric IOL Alignment NEW The new IOLMaster 500 from ZEISS Defining biometry Markerless Toric IOL Alignment The moment you trust the experience of 100 million IOL power calculations. This is the moment we work for. 2 // IOLMASTER

More information

FDA 510(k)-cleared OCT system for ophthalmic surgery SEE WHAT YOU VE BEEN MISSING. EnFocus intrasurgical OCT

FDA 510(k)-cleared OCT system for ophthalmic surgery SEE WHAT YOU VE BEEN MISSING. EnFocus intrasurgical OCT FDA 510(k)-cleared OCT system for ophthalmic surgery SEE WHAT YOU VE BEEN MISSING EnFocus intrasurgical OCT SEE WHAT YOU VE DURING YOUR SU Make the best-informed surgical decisions for your patient with

More information

PalmScan PRO 5 in 1 Biometer Your Complete Biometry System - Fully Configurable

PalmScan PRO 5 in 1 Biometer Your Complete Biometry System - Fully Configurable B-Scan A-Scan Pachymeter Keratometer UBM PalmScan PRO 5 in 1 Biometer Your Complete Biometry System - Fully Configurable A-Scan + IOL Calculator Keratometer Pachymeter B-Scan UBM www.micromedinc.com 818.222.3310

More information

Updated Protocol to Provide Best Vision after CXL in Keratoconus

Updated Protocol to Provide Best Vision after CXL in Keratoconus Updated Protocol to Provide Best Vision after CXL in Keratoconus Mohamed Shafik Shaheen MD, PhD Professor of Ophthalmology, University of Alexandria, Horus Vision Correction Center, Egypt What is after

More information

3D SWEPT SOURCE OCT. Very high scanning speed: 30,000 A-Scans/sec. 130,800 A-Scans. Cut plane 16 x 16 x 6 mm. Topo/Pachy Map in 0.3 sec.

3D SWEPT SOURCE OCT. Very high scanning speed: 30,000 A-Scans/sec. 130,800 A-Scans. Cut plane 16 x 16 x 6 mm. Topo/Pachy Map in 0.3 sec. 3D SWEPT SOURCE OCT FOURIER DOMAIN OCT CASIA SS-1000 Very high scanning speed: 30,000 A-Scans/sec. 130,800 A-Scans Cut plane 16 x 16 x 6 mm Topo/Pachy Map in 0.3 sec. Free adjustable display in 2D and

More information

ioct Discover a new dimension with intraoperative OCT

ioct Discover a new dimension with intraoperative OCT ioct Discover a new dimension with intraoperative OCT tradition and innovation Since 1858 visionary thinking and a fascination with technology have guided us to develop innovative products of outstanding

More information

High incidence of rainbow glare after femtosecond laser assisted-lasik using the upgraded FS200 femtosecond laser

High incidence of rainbow glare after femtosecond laser assisted-lasik using the upgraded FS200 femtosecond laser Zhang and Chen BMC Ophthalmology (2018) 18:71 https://doi.org/10.1186/s12886-018-0734-1 RESEARCH ARTICLE Open Access High incidence of rainbow glare after femtosecond laser assisted-lasik using the upgraded

More information

Why a phakic IOL? Solving High Myopia Problems: Iris Fixated IOLs: Installation and Removal. Initial Step: Commit to their Usefulness

Why a phakic IOL? Solving High Myopia Problems: Iris Fixated IOLs: Installation and Removal. Initial Step: Commit to their Usefulness Solving High Myopia Problems: Iris Fixated IOLs: Installation and Removal David R. Hardten, M.D. Minneapolis, Minnesota Have done research, consulting, or speaking for: Allergan, AMO, Calhoun Vision, CXL-USA,

More information

Wavefront (Center) 502. EMPOWER YOUR PRACTICE WITH comprehensive complete anterior segment analysis

Wavefront (Center) 502. EMPOWER YOUR PRACTICE WITH comprehensive complete anterior segment analysis Wavefront 584 547 494 493 (Center) 502 496 507 520 529 559 EMPOWER YOUR PRACTICE WITH comprehensive complete anterior segment analysis Narrow Angles Cataracts Glaucoma Risk THE POWER OF THREE The VX130

More information

Ophthalmic Lenses Single use and reusable

Ophthalmic Lenses Single use and reusable Ophthalmic Lenses Single use and reusable Single use lenses Clinic All lenses have a custom anti-reflection coating and can be used with the appropriate therapeutic lasers.* Each lens comes in a sterile

More information

LASIK Ablation Centration: An Objective Digitized Assessment and Comparison Between Two Generations of an Excimer Laser

LASIK Ablation Centration: An Objective Digitized Assessment and Comparison Between Two Generations of an Excimer Laser ORIGINAL ARTICLE LASIK Ablation Centration: An Objective Digitized Assessment and Comparison Between Two Generations of an Excimer Laser Anastasios John Kanellopoulos, MD; George Asimellis, PhD ABSTRACT

More information

HOYA isert 351 toric

HOYA isert 351 toric HOYA isert 351 toric Patient selection Suitable patient: ametropia with corneal astigmatism > 1.0 D regular astigmatism stable cornea wish for glasses independence / realistic expectations and motivation

More information

Effect of lamellar flap location on corneal topography after laser in situ keratomileusis

Effect of lamellar flap location on corneal topography after laser in situ keratomileusis Effect of lamellar flap location on corneal topography after laser in situ keratomileusis Neal E. Ginsberg, MD, Peter S. Hersh, MD ABSTRACT Purpose: To investigate the effect of hinge position on corneal

More information

How to Refine Your Refractive Error Post-Phaco with Premium IOL s. Astigmatism & Multifocal IOL s. Coma & Multifocal IOL OPERATIVE

How to Refine Your Refractive Error Post-Phaco with Premium IOL s. Astigmatism & Multifocal IOL s. Coma & Multifocal IOL OPERATIVE How to Refine Your Refractive Error Post-Phaco with Premium IOL s Mounir Khalifa, MD, PhD Prof of Ophthalmology, Tanta University President of Egyptian Refractive Club Chairman of Horus Vision Correction

More information

Meta-analysis of Six Excimer Laser Platforms for Safety and Efficacy in Myopic Laser-assisted in situ Keratomileusis. Christopher L Blanton, MD

Meta-analysis of Six Excimer Laser Platforms for Safety and Efficacy in Myopic Laser-assisted in situ Keratomileusis. Christopher L Blanton, MD Cornea Meta-analysis of Six Excimer Laser for Safety and Efficacy in Myopic Laser-assisted in situ Keratomileusis Christopher L Blanton, MD President, Board of Directors; Chief Executive Officer, Inland

More information

Imaging of the Cornea. Arun Brahma

Imaging of the Cornea. Arun Brahma Imaging of the Cornea Arun Brahma 1 In the last 30 years we have advanced rapidly in relation to corneal imaging due to Refractive Surgery Keratometer 1880-1990 was the Gold standard. Placido topography-

More information

OCULUS Pentacam Pentacam HR

OCULUS Pentacam Pentacam HR OCULUS Pentacam Pentacam HR The Gold Standard in Anterior Segment Tomography We focus on progress Providing the best care to your patients > The eye is extremely sensitive. Loss or impairment of sight

More information

In Vivo Application and Imaging of Intralenticular Femtosecond Laser Pulses for the Restoration of Accommodation

In Vivo Application and Imaging of Intralenticular Femtosecond Laser Pulses for the Restoration of Accommodation In Vivo Application and Imaging of Intralenticular Femtosecond Laser Pulses for the Restoration of Accommodation Silvia Schumacher, MSc; Michael Fromm, MSc; Uwe Oberheide, PhD; Georg Gerten, MD; Alfred

More information

ORBSCAN Corneal Imaging M.Nejabat

ORBSCAN Corneal Imaging M.Nejabat ORBSCAN Corneal Imaging M.Nejabat Shiraz University of medical sciences Topographic technologies Placido disk based topography AstraMax : ( three-dimensional topography ) Elevation-based topography: Slit-scanning

More information

Kevin M. Miller, MD Kolokotrones Professor of Clinical Ophthalmology David Geffen School of Medicine at UCLA

Kevin M. Miller, MD Kolokotrones Professor of Clinical Ophthalmology David Geffen School of Medicine at UCLA IOL Power Calculation l in Post-LASIK Eyes Kevin M. Miller, MD Kolokotrones Professor of Clinical Ophthalmology David Geffen School of Medicine at UCLA Jules Stein Eye Institute I have no financial disclosures

More information

Wavefront Diagnostic. One-Touch COMPREHENSIVE VISUAL ASSESSMENT IN UNDER 90 SECONDS.

Wavefront Diagnostic. One-Touch COMPREHENSIVE VISUAL ASSESSMENT IN UNDER 90 SECONDS. Wavefront Diagnostic One-Touch COMPREHENSIVE VISUAL ASSESSMENT IN UNDER 90 SECONDS. VX120 A GAME CHANGING WAVEFRONT DIAGNOSTIC DEVICE FOR COMPREHENSIVE VISUAL ASSESSMENT REFRACTION AND VISUAL PERFORMANCE

More information

YOUR WAY TO PRECISE OUTCOMES

YOUR WAY TO PRECISE OUTCOMES Microscope systems for markerless IOL alignment during cataract surgery YOUR WAY TO PRECISE OUTCOMES 2D and 3D IOL guidance systems 2 YOUR WAY TO PRECISE OUTCOMES Drive minimum residual astigmatism for

More information

Finite Element Model of Cornea Deformation

Finite Element Model of Cornea Deformation Finite Element Model of Cornea Deformation Jessica R. Crouch 1, John C. Merriam 2, Earl R. Crouch 3 1 Department of Computer Science, Old Dominion University, Virginia, USA, jrcrouch@odu.edu 2 Department

More information

Slide 1. Slide 2. Slide 3 3 CATEGORIES. 4 th CATEGORY Depth-of-Focus. Depth-of-Focus Lenses. Historically Intraocular Lenses

Slide 1. Slide 2. Slide 3 3 CATEGORIES. 4 th CATEGORY Depth-of-Focus. Depth-of-Focus Lenses. Historically Intraocular Lenses Slide 1 Depth-of-Focus Lenses Slide 2 Historically Intraocular Lenses 3 CATEGORIES Traditional Monofocal Monofocal Toric Multi-focal 4 th CATEGORY Depth-of-Focus Slide 3 Monofocal and Monofocal Toric lenses

More information

Measure at the speed of light...

Measure at the speed of light... Measure at the speed of light... LENSTAR LS 900 Biometry Explore new dimensions... Complete optical biometer including CCT and lens thickness Align once, get all results fast biometrical assessment Non

More information

Nomograms. Michael Mrochen IROC - Institute for Refractive and Ophthalmic Surgery

Nomograms. Michael Mrochen IROC - Institute for Refractive and Ophthalmic Surgery Nomograms Michael Mrochen IROC - Institute for Refractive and Ophthalmic Surgery Background Main reason for re-treatments in refractive surgery are over- or under-correction in sphere and cylinder Re-treatments

More information

festta d.o.o Zagreb, Braće Cvijića 32 tel (0) , fax (0)

festta d.o.o Zagreb, Braće Cvijića 32 tel (0) , fax (0) ZASTUPNIK I SERVIS : festta d.o.o. 10000 Zagreb, Braće Cvijića 32 tel. ++385 (0)1 36 35 500, fax. ++385 (0)1 36 36 760 e-mail : festta@festta.hr www.festta.hr OCULUS PENTACAM BASIC CLASSIC We focus on

More information

EnFocus Your Upgrade Path to High Performance Intrasurgical OCT

EnFocus Your Upgrade Path to High Performance Intrasurgical OCT Your Upgrade Path to High Performance Intrasurgical OCT is FDA 510(k) Cleared > Ultra HD OCT EXTEND YOUR MICROSCOPE S POTENTIAL WITH INTRASURGICAL OCT Brilliant Images, Sub-Surface Knowledge is an intrasurgical

More information

ONEFIT TM MED PUTS YOU IN CONTROL: Full customization when a larger diameter is needed for highly irregular, medically indicated or normal corneas.

ONEFIT TM MED PUTS YOU IN CONTROL: Full customization when a larger diameter is needed for highly irregular, medically indicated or normal corneas. ONEFIT TM MED PUTS YOU IN CONTROL: Full customization when a larger diameter is needed for highly irregular, medically indicated or normal corneas. FITTING GUIDE Applications Design Options IRREGULAR CORNEAS

More information

Optimal cornea shape design problem for corneal refractive surgery

Optimal cornea shape design problem for corneal refractive surgery 10 th World Congress on Structural and Multidisciplinary Optimization May 19-4, 013, Orlando, Florida, USA Optimal cornea shape design problem for corneal refractive surgery Takaki Nakayama, Hisashi Naito,

More information

Ophthalmic Lenses Single use and reusable

Ophthalmic Lenses Single use and reusable Ophthalmic Lenses Single use and reusable Single use lenses Clinic All lenses have a custom anti-reflection coating* and can be used with the appropriate therapeutic lasers. Each lens comes in a sterile

More information

Prediction of intraocular lens position based on crystalline lens shape measured using anterior segment optical coherence tomography

Prediction of intraocular lens position based on crystalline lens shape measured using anterior segment optical coherence tomography Original Contribution Kitasato Med J 2017; 47: 110-117 Prediction of intraocular lens position based on crystalline lens shape measured using anterior segment optical coherence tomography Shuntaro Tsunehiro,

More information

Robot Control for Medical Applications and Hair Transplantation

Robot Control for Medical Applications and Hair Transplantation Dr. John Tenney Director of Research Restoration Robotics, Inc. Robot Control for Medical Applications and Hair Transplantation Presented to the IEEE Control Systems Society, Santa Clara Valley 18 November

More information

IOVS - IOVS R2. Total corneal power estimation: Ray tracing method vs. Gaussian optics formula

IOVS - IOVS R2. Total corneal power estimation: Ray tracing method vs. Gaussian optics formula IOVS - IOVS-0-.R Total corneal power estimation: Ray tracing method vs. Gaussian optics formula Journal: Investigative Ophthalmology & Visual Science Manuscript ID: IOVS-0-.R Manuscript Type: Article Date

More information

GONIOSCOPY Gonioscopy is a technique that allows visualization of the anterior chamber angle structures and is used to diagnose abnormalities of the a

GONIOSCOPY Gonioscopy is a technique that allows visualization of the anterior chamber angle structures and is used to diagnose abnormalities of the a Gonioscopic Evaluation of the Anterior Chamber Angle University of Milan Bicocca June 2010 Anthony Cavallerano, O.D. VA Boston Health Care System Draft Only The New England College of Optometry Boston

More information

DOM 3000 Series Dental Microscopes For Dentistry, For you

DOM 3000 Series Dental Microscopes For Dentistry, For you See more,treat more Version: DOM3000s MS en 2016/A. Semorr Medical Tech 2016. Printed in China. Pics, Specifications and Technical data subject to change without advance notifications. DOM 3000 Series

More information

SEE BEYOND. Ophthalmic Surgical Microscope Proveo 8

SEE BEYOND. Ophthalmic Surgical Microscope Proveo 8 SEE BEYOND Ophthalmic Surgical Microscope Proveo 8 One of the benefits with Proveo 8 is the way the illumination is achieved by four coaxial LED lights. The optics of the microscope and the innovative

More information

Total Corneal Power Estimation: Ray Tracing Method versus Gaussian Optics Formula PATIENTS AND METHODS

Total Corneal Power Estimation: Ray Tracing Method versus Gaussian Optics Formula PATIENTS AND METHODS Cornea Total Corneal Power Estimation: Ray Tracing Method versus Gaussian Optics Formula Li Wang, 1 Ashraf M. Mahmoud, 2 Betty Lise Anderson, 3 Douglas D. Koch, 1 and Cynthia J. Roberts 2 PURPOSE. To evaluate

More information

Cataract l Glaucoma l Retina l Refractive. SL 120 Slit Lamp. The powerful all-rounder.

Cataract l Glaucoma l Retina l Refractive. SL 120 Slit Lamp. The powerful all-rounder. Cataract l Glaucoma l Retina l Refractive SL 120 Slit Lamp. The powerful all-rounder. Slit lamps by Carl Zeiss. Optics of the finest. The successful synthesis of high optical performance and optimized

More information

Welcome to the World of Scleral Lenses (Fitting Workshop)

Welcome to the World of Scleral Lenses (Fitting Workshop) Welcome to the World of Scleral Lenses (Fitting Workshop) 1409 Kensington Blvd. Bowling Green, OH 43402 Mile Brujic, O.D., F.A.A.O. Dave Kading, O.D., F.A.A.O. Lynette Johns, O.D., F.A.A.O. Summary This

More information

Custom Stable Fitting Set Preparation, Cleaning & Sterilization

Custom Stable Fitting Set Preparation, Cleaning & Sterilization FITTING GUIDE Table of Contents Preparation, Cleaning & Sterilization 1 About the Custom Stable 2 Basic Fitting Principals 3 Adding Front Toric 9 Fitting the Custom Stable Aurora 11 Troubleshooting the

More information

December Press Conference

December Press Conference December Press Conference Carl Zeiss Group Stuttgart, December 12, 2007 Dr. Dieter Kurz President & CEO Dr. Michael Kaschke CFO Carl Zeiss December Press Conference, Stuttgart, December 12, 2007 1 Carl

More information

MEL 80 High performance meets versatility

MEL 80 High performance meets versatility MEL 80 High performance meets versatility Just what your clinic is looking for Invest in the latest refractive excimer technology The MEL 80 is a top quality Carl Zeiss Meditec product, designed to make

More information

SCHWIND Diagnostic Devices Experience a new Level of Convenience

SCHWIND Diagnostic Devices Experience a new Level of Convenience SCHWIND Diagnostic Devices Experience a new Level of Convenience DIAGNOSTIC DEVICES 2 DIAGNOSTIC DEVICES SCHWIND Diagnostic Devices High-precision, multifunctional, user-friendly SCHWIND Diagnostic Devices

More information

El- T O O K H Y, Omar

El- T O O K H Y, Omar Global Veterinary Summit August 31-September 2, 2015 Florida, USA C A I R O U N I V E R S I T Y E G Y P T El- T O O K H Y, Omar 欧玛尔 Points to be Discussed 1 2 3 4 5 6 7 8 Eye vs Schematic eye, models of

More information

Real-world applications of intense light matter interaction beyond the scope of classical micromachining.

Real-world applications of intense light matter interaction beyond the scope of classical micromachining. Dr. Lukas Krainer lk@onefive.com CEO Real-world applications of intense light matter interaction beyond the scope of classical micromachining. 1 Management & Company Company Based in Zürich, Switzerland

More information

Photokeratoscopy in fitting contact lens after

Photokeratoscopy in fitting contact lens after British Journal of Ophthalmology, 1986, 70, 55-59 Photokeratoscopy in fitting contact lens after penetrating keratoplasty REIZO MANABE, MAMORU MATSUDA, AND TSUNEJI SUDA From the Department of Ophthalmology,

More information

Stellaris PC System: Premium Performance Precise Control Integrated Versatile Intuitive

Stellaris PC System: Premium Performance Precise Control Integrated Versatile Intuitive Stellaris PC System: Premium Performance Precise Control Integrated Versatile Intuitive 02 / Fully Integrated Stellaris PC System: Fully Integrated Complete combined surgical system Combined surgical system

More information

The Connect Platform A-SCAN PLUS CONNECT B-SCAN PLUS UBM PLUS. Diagnostic Ultrasound... Dedicated Support.

The Connect Platform A-SCAN PLUS CONNECT B-SCAN PLUS UBM PLUS. Diagnostic Ultrasound... Dedicated Support. The Connect Platform A-SCAN PLUS CONNECT B-SCAN PLUS UBM PLUS Diagnostic Ultrasound... Dedicated Support. The Connect Platform A-Scan Plus Connect Item# 24-4400 Features Immersion and contact modes Industry

More information

Trial for New Intraocular Lens Power Calculation Following Phototherapeutic Keratectomy

Trial for New Intraocular Lens Power Calculation Following Phototherapeutic Keratectomy Trial for New Intraocular Lens Power Calculation Following Phototherapeutic Keratectomy Takashi Ishikawa,* Azuma Hirano,* Junko Inoue,* Kiyoo Nakayasu,* Atsushi Kanai,* Kunihiko Takeuchi and Takayuki Kanda

More information

MEL 80 High performance meets versatility

MEL 80 High performance meets versatility MEL 80 High performance meets versatility // MEL 80 Made By Carl Zeiss 2 Just what your clinic is looking for Invest in the latest refractive excimer technology The MEL 80 is a top quality Carl Zeiss Meditec

More information

"Using a Systematic Approach when Fitting Keratoconus, Irregular and Post Surgical Corneas" Dr. Paul Rose OD

Using a Systematic Approach when Fitting Keratoconus, Irregular and Post Surgical Corneas Dr. Paul Rose OD Dr. Paul Rose OD New Zealand New Zealand Some facts Has 4m people and 40m sheep Is a 3 hours flight from Australia Is an 13 hour direct flight from Vancouver Local sport is rugby/ All Blacks Home of the

More information

Applications in Ophthalmology

Applications in Ophthalmology Applications in Ophthalmology July 2017 Dr. David Leuenberger, Business Development Manager Bernstrasse 388 CH-8953 Dietikon Switzerland Phone +41 58 856 3011 www.optotune.com info@optotune.com Agenda

More information

Chapter 7: Geometrical Optics. The branch of physics which studies the properties of light using the ray model of light.

Chapter 7: Geometrical Optics. The branch of physics which studies the properties of light using the ray model of light. Chapter 7: Geometrical Optics The branch of physics which studies the properties of light using the ray model of light. Overview Geometrical Optics Spherical Mirror Refraction Thin Lens f u v r and f 2

More information

Scheimpflug photography keratometry readings for routine intraocular lens power calculation

Scheimpflug photography keratometry readings for routine intraocular lens power calculation ARTICLE Scheimpflug photography keratometry readings for routine intraocular lens power calculation H. John Shammas, MD, Kenneth J. Hoffer, MD, Maya C. Shammas, MD PURPOSE: To prospectively evaluate keratometry

More information

Sample Introduction Systems SOLID LASER ABLATION

Sample Introduction Systems SOLID LASER ABLATION Sample Introduction Systems SOLID LASER ABLATION Laser ablation Benefits: spatial resolution of < 10 um little to no sample preparation required Drawbacks: transient signal reduced precision/accuracy relative

More information

In Vivo Prediction of Air-Puff Induced Corneal Deformation Using LASIK, SMILE, and PRK Finite Element Simulations

In Vivo Prediction of Air-Puff Induced Corneal Deformation Using LASIK, SMILE, and PRK Finite Element Simulations Cornea In Vivo Prediction of Air-Puff Induced Corneal Deformation Using LASIK, SMILE, and PRK Finite Element Simulations Mathew Francis, 1 Pooja Khamar, 2 Rohit Shetty, 2 Kanchan Sainani, 2 Rudy M. M.

More information

810 nm. 980 nm FOX nm 12 W VERSATILE FOX 810/980/ 1064/1470 nm IDEAL FOR: DENTAL ENT DERMATOLOGY GYNECOLOGY SURGERY / VET.

810 nm. 980 nm FOX nm 12 W VERSATILE FOX 810/980/ 1064/1470 nm IDEAL FOR: DENTAL ENT DERMATOLOGY GYNECOLOGY SURGERY / VET. 810 1064 980 12 W 980 VERSATILE 810/980/ 1064/1470 IDEAL FOR: DENTAL ENT DERMATOLOGY GYNECOLOGY SURGERY / VET www.arclaser.com PRECISION & PERFECTION CALIBRATION at the distal tip of the fiber = safe and

More information

EFFICIENCY YOU CAN FEEL, PRECISION YOU CAN TRUST

EFFICIENCY YOU CAN FEEL, PRECISION YOU CAN TRUST Designed in Switzerland for anterior and posterior ophthalmic surgery EFFICIENCY YOU CAN FEEL, PRECISION YOU CAN TRUST Proveo 8 Ophthalmic Surgical Microscope Features such as the excellent and brilliant

More information

HS Hi-R NEO 900 For first class surgery

HS Hi-R NEO 900 For first class surgery HS Hi-R NEO 900 For first class surgery Strong Name Strong Product Our highlights: Enjoy high optical visualization with Haag-Streit SurgicaL s microscope HS Hi-R NEO 900 for ophthalmology and hand surgery.

More information

A TOPCON EXAM SOLUTION. Topcon Slit Lamp Series.» Quality» Precision» Durability

A TOPCON EXAM SOLUTION. Topcon Slit Lamp Series.» Quality» Precision» Durability A TOPCON EXAM SOLUTION Topcon Slit Lamp Series» Quality» Precision» Durability Quality. Precision. Durability. The Topcon family of slit lamps include a wide variety of models including traditional clinical

More information

EyeMag Loupes from ZEISS Seeing is believing

EyeMag Loupes from ZEISS Seeing is believing EyeMag Loupes from ZEISS Seeing is believing 2 ZEISS EyeMag Medical Loupes Precision at first sight Medicine today requires meticulous attention to detail. Seeing tiny anatomical structures isn t possible

More information

Evaluations and geometrical measurements of the human eye in order to establish the design parameters for the customized contact lens

Evaluations and geometrical measurements of the human eye in order to establish the design parameters for the customized contact lens IOP Conference Series: Materials Science and Engineering PAPER OPEN ACCESS Evaluations and geometrical measurements of the human eye in order to establish the design parameters for the customized contact

More information

LENSTAR LS 900 Improving outcomes

LENSTAR LS 900 Improving outcomes LENSTAR LS 900 Improving outcomes Tradition and Innovation Since 1858, visionary thinking and a fascination with technology have guided us to develop innovative products of outstanding reliability: Anticipating

More information

Keratoconus is a bilateral non-inflammatory degenerative

Keratoconus is a bilateral non-inflammatory degenerative Basic Research Mathematical analysis of corneal remodelling after intracorneal ring surgery in keratoconus Elias F. Jarade 1,2, Elise Slim 1,3, Carole Cherfan 1, Hala El Rami 3, Toufic Hassan 3, Elias

More information

URGENT: MEDICAL DEVICE RECALL

URGENT: MEDICAL DEVICE RECALL Wednesday, September 20, 2017 [Contact Name] Andrew Lindsay QM Manager [Business Name] [Customer Address] [City, State, Zip Code] Carl Zeiss Ltd. 509 Coldhams Lane Cambridge Cambridgeshire CB1 3JS U.K.

More information

Medicine. Longitudinal Evaluation of Cornea With Swept-Source Optical Coherence Tomography and Scheimpflug Imaging Before and After Lasik

Medicine. Longitudinal Evaluation of Cornea With Swept-Source Optical Coherence Tomography and Scheimpflug Imaging Before and After Lasik Medicine OBSERVATIONAL STUDY Longitudinal Evaluation of Cornea With Swept-Source Optical Coherence Tomography and Scheimpflug Imaging Before and After Lasik Tommy C.Y. Chan, MMedSc, FRCS, Sayantan Biswas,

More information

AP Physics: Curved Mirrors and Lenses

AP Physics: Curved Mirrors and Lenses The Ray Model of Light Light often travels in straight lines. We represent light using rays, which are straight lines emanating from an object. This is an idealization, but is very useful for geometric

More information

Holladay Report Pages

Holladay Report Pages Jack T. Holladay, MD, MSEE, FACS Holladay Report Interpretation Guidelines 2015 Page 1 of 14 Pentacam Interpretation Guideline (Software 1.20b68 or later) Holladay Report 2015 2 Pages This Holladay Report

More information

More space, better access: DPMI PRO magis on the S S Floor Stand

More space, better access: DPMI PRO magis on the S S Floor Stand Surgical Microscopes from Carl Zeiss More space, better access: DPMI PRO magis on the S S Floor Stand ZEISS DPMI The is on the S В - for microsurgery Every microsurgical intervention requires a special

More information

2011 Optical Science & Engineering PhD Qualifying Examination Optical Sciences Track: Advanced Optics Time allowed: 90 minutes

2011 Optical Science & Engineering PhD Qualifying Examination Optical Sciences Track: Advanced Optics Time allowed: 90 minutes 2011 Optical Science & Engineering PhD Qualifying Examination Optical Sciences Track: Advanced Optics Time allowed: 90 minutes Answer all four questions. All questions count equally. 3(a) A linearly polarized

More information

(Goal 3) (Goal 3) (Goals 4 and 5) (Goals 4 and 5)

(Goal 3)  (Goal 3) (Goals 4 and 5) (Goals 4 and 5) 10 This thesis addresses the measurement of geometrical properties (surface geometry, tilt and decentration) of the crystalline lens in normal eyes, and their changes with accommodation. In addition, it

More information

OCULUS Pentacam /Pentacam HR Anterior Segment Tomography

OCULUS Pentacam /Pentacam HR Anterior Segment Tomography OCULUS Pentacam /Pentacam HR Anterior Segment Tomography OCULUS Pentacam /Pentacam HR The Gold Standard for Anterior Segment Tomography Since its introduction in 2002 the OCULUS Pentacam has proven to

More information

Determination of Excimer Laser Ablation Rate of the Human Cornea Using In Vivo Scheimpflug Videography

Determination of Excimer Laser Ablation Rate of the Human Cornea Using In Vivo Scheimpflug Videography Determination of Excimer Laser Ablation Rate of the Human Cornea Using In Vivo Scheimpflug Videography Hans-Joachim Huebscher* Uwe Genth,\ and Theo Seilerf Purpose. To determine in vivo the amount of human

More information

HOW TO IMPROVE REFRACTIVE OUTCOMES WITH IMMERSION BIOMETRY?

HOW TO IMPROVE REFRACTIVE OUTCOMES WITH IMMERSION BIOMETRY? HOW TO IMPROVE REFRACTIVE OUTCOMES WITH IMMERSION BIOMETRY? Andrzej Dmitriew Department of Ophthalmology Poznan University of Medical Sciences ACCURATE IOL CALCULATION 90-95% of patients within ±0,5 D

More information

Optimizing intraocular lens power calculations in eyes with axial lengths above 25.0 mm

Optimizing intraocular lens power calculations in eyes with axial lengths above 25.0 mm ARTICLE Optimizing intraocular lens power calculations in eyes with axial lengths above 25.0 mm Li Wang, MD, PhD, Mariko Shirayama, MD, Xingxuan Jack Ma, Thomas Kohnen, MD, PhD, FEBO, Douglas D. Koch,

More information

EV3.0 CAMERA CONTROL UNIT

EV3.0 CAMERA CONTROL UNIT EV3.0 CAMERA CONTROL UNIT Article Code PV630 Universal camera platform accepts 2D and 3D camera heads (for further information about the 2D Camera Heads please visit the APP/ Chapter 2D Technology/ Key

More information

Lecture 4 Recap of PHYS110-1 lecture Physical Optics - 4 lectures EM spectrum and colour Light sources Interference and diffraction Polarization

Lecture 4 Recap of PHYS110-1 lecture Physical Optics - 4 lectures EM spectrum and colour Light sources Interference and diffraction Polarization Lecture 4 Recap of PHYS110-1 lecture Physical Optics - 4 lectures EM spectrum and colour Light sources Interference and diffraction Polarization Lens Aberrations - 3 lectures Spherical aberrations Coma,

More information

Other Laser Surgery Laser Tonsillectomy Use CO 2 with mirror bouncing system Operation takes 15 minutes, no pain Cauterizes blood vessels & Lymphatic

Other Laser Surgery Laser Tonsillectomy Use CO 2 with mirror bouncing system Operation takes 15 minutes, no pain Cauterizes blood vessels & Lymphatic Other Laser Surgery Laser Tonsillectomy Use CO 2 with mirror bouncing system Operation takes 15 minutes, no pain Cauterizes blood vessels & Lymphatic vessels no blood in throat Patient eat & drink just

More information

Design of Computer-Generated Hologram With Ring Focus for Nonmechanical Corneal Trephination With Er:YAG Laser in Penetrating Keratoplasty

Design of Computer-Generated Hologram With Ring Focus for Nonmechanical Corneal Trephination With Er:YAG Laser in Penetrating Keratoplasty LABORATORY INVESTIGATIONS Design of Computer-Generated Hologram With Ring Focus for Nonmechanical Corneal Trephination With Er:YAG Laser in Penetrating Keratoplasty Achim Langenbucher, Berthold Seitz,

More information

EyeMag Medical Loupes from ZEISS Seeing is believing

EyeMag Medical Loupes from ZEISS Seeing is believing EyeMag Medical Loupes from ZEISS Seeing is believing Treating with flexibility. ZEISS EyeMag Medical Loupes // RESPONSIBILITY MADE BY ZEISS ZEISS EyeMag Medical Loupes Precision at first sight Medicine

More information

The I Kone Lens. Boston XO. Valley CONTAX. Springfield, OR. Manufactured in

The I Kone Lens. Boston XO. Valley CONTAX. Springfield, OR. Manufactured in The I Kone Lens Manufactured in Boston XO Valley CONTAX Springfield, OR Contact Lens Fitting Goals for Keratoconus Vision Comfort Corneal Health Fit / Centration Happy Patient Selecting the Best Contact

More information

Industrial Fiber Beam Delivery for Ultrafast Lasers

Industrial Fiber Beam Delivery for Ultrafast Lasers Photonic Tools GmbH, 2017 Industrial Fiber Beam Delivery for Ultrafast Lasers System Technology and Industrial Application Bastian Kruschke 15.11.2017 Swissphotonics Workshop Specialty Optical Fibers Motivation

More information

Real Time Process Control with Optical Coherence Tomography

Real Time Process Control with Optical Coherence Tomography Real Time Process Control with Optical Coherence Tomography 16th of June 2016, Ch. Meier Bern HUCE, University OPTOLAB of Applied Science HuCE-optoLabt Overview Short introduction to OCT Systems Resolution

More information

Taiwan Journal of Ophthalmology

Taiwan Journal of Ophthalmology Taiwan Journal of Ophthalmology 2 (2012) 25e30 Contents lists available at SciVerse ScienceDirect Taiwan Journal of Ophthalmology journal homepage: www.e-tjo.com Original article Predictability of intraocular

More information

S100 / OPMI pico. OPMI pico from ZEISS Performance you can trust

S100 / OPMI pico. OPMI pico from ZEISS Performance you can trust S100 / OPMI pico OPMI pico from ZEISS Performance you can trust Keeping you focused on what matters most Whether for ear, nose or laryngeal procedures, ENT specialists around the world put their trust

More information

Humphrey Field Analyzer 3 from ZEISS The best just got better. NEW HFA3 with Liquid Lens Technology

Humphrey Field Analyzer 3 from ZEISS The best just got better. NEW HFA3 with Liquid Lens Technology Humphrey Field Analyzer 3 from ZEISS The best just got better NEW HFA3 with Liquid Lens Technology The moment you discover how your NEW Humphrey accelerates clinic fl ow. This is the moment we work for.

More information

Introduction. Misconceptions

Introduction. Misconceptions ix Even today, corneal topography remains one of the most misunderstood diagnostic tools for the clinician, despite its apparent simplicity, due to unrecognized complexities and oversimplification of formulas.

More information

Lightsheet Z.1. Light Sheet Fluorescence Microscopy by Carl Zeiss. Fabrice Schmitt, Sales Manager Carl ZEISS France

Lightsheet Z.1. Light Sheet Fluorescence Microscopy by Carl Zeiss. Fabrice Schmitt, Sales Manager Carl ZEISS France Lightsheet Z.1 Light Sheet Fluorescence Microscopy by Carl Zeiss Fabrice Schmitt, Sales Manager Carl ZEISS France 12.12.2012 Light Sheet Fluorescence Microscopy (LSFM) Principle The Principle of Light

More information

FEMTO-CATARACT INSTRUMENTS Speculum SPECULUM FOR DOCKING STATION

FEMTO-CATARACT INSTRUMENTS Speculum SPECULUM FOR DOCKING STATION Speculum SPECULUM FOR DOCKING STATION TM Slade- Murdoch Speculum: AE-1033 Blades specially curved to accommodate Femtosecond laser docking station Self locking mechanism for quick installation and removal

More information

Excimer laser photorefractive keratectomy

Excimer laser photorefractive keratectomy Intraocular Lens Power Calculation for Cataract Surgery after Photorefractive Keratectomy for High Myopia Richard S. Kalski, MD; Jean-Pierre Danjoux, FRCOphth; Graham E. Fraenkel, BM, BS; Michael A. Lawless,

More information

KSK 150 FC, Kolposkop E, S100 / OPMI pico. Colposcopes from ZEISS Enabling enhanced diagnostics

KSK 150 FC, Kolposkop E, S100 / OPMI pico. Colposcopes from ZEISS Enabling enhanced diagnostics KSK 150 FC, Kolposkop E, S100 / OPMI pico Colposcopes from ZEISS Enabling enhanced diagnostics Early detection with ZEISS colposcopes Reliability for your patients ZEISS Kolposkop 150 FC ZEISS Kolposkop

More information

Multisensor Coordinate Measuring Machines ZEISS O-INSPECT

Multisensor Coordinate Measuring Machines ZEISS O-INSPECT Multisensor Coordinate Measuring Machines ZEISS O-INSPECT Having all the necessary options for reliable measurements. ZEISS O-INSPECT // RELIABILITY MADE BY ZEISS 2 The O-INSPECT multisensor measuring

More information

Department of Ophthalmology, Seoul National University College of Medicine, Seoul, Korea 2

Department of Ophthalmology, Seoul National University College of Medicine, Seoul, Korea 2 pissn: 1011-8942 eissn: 2092-9382 Korean J Ophthalmol 2015;29(3):195-202 http://dx.doi.org/10.3341/kjo.2015.29.3.195 Original Article Estimation of Intraocular Lens Power Calculation after Myopic Corneal

More information

EPSRC Centre for Doctoral Training in Industrially Focused Mathematical Modelling

EPSRC Centre for Doctoral Training in Industrially Focused Mathematical Modelling EPSRC Centre for Doctoral Training in Industrially Focused Mathematical Modelling More Accurate Optical Measurements of the Cornea Raquel González Fariña Contents 1. Introduction... 2 Background... 2 2.

More information