Version 4.0. User Guide of Plantyst Box

Size: px
Start display at page:

Download "Version 4.0. User Guide of Plantyst Box"

Transcription

1 Version 4.0 User Guide of Plantyst Box

2 The company Plantyst delivers by means of lease a specialized hardware device called Plantyst box. It is designed to collect data directly from the clients machines. Plantyst box is an industrial computer which is located in black steel case and is designed to monitor the production equipment. The monitoring is based on measuring the pulses, that correspond to production unit. The Box is the only equipment, which is placed in production shop, it is not necessary to install any server or data storage units. The Box is delivered together with power supply adapter. As a standard it is delivered the power supply 12 V DC, 2 A with bipolar socket connector, designed to inner voltage V AC / 50 Hz. Power consumption typically 5 W, max. 20 W. Optionally could be supplied adapter to DIN rail into the Control Cabinet. 1. Technical Description There are state LEDs placed on the top side of the Box, with following value: LED POWER signalizes connection of corresponding power supply LED READY signalizes successful booting of the System and run of main processes (when starting, the LED flashes three times shortly) LED CONNECTED signalized availability of connection between Box and Plantyst servers (see chapter Diagnostic of Communication) There is DIN rail on Bottom side Picture 1. Front panel of the Plantyst box On the front panel there are connectors designed for connections of Plantyst Box and identification tag. The Purpose od individual connectors is described in following chapters. 2

3 1.1. Power Supply of Plantyst Box The Connector for Power Supply is marked as POWER and is places in the front panel, left lower side. The purpose od individual pins od input power connector is marked on the box (from left): plus, minus. Box is safety protection against interchange of polarity and possible power supply overvoltage. Correct connection of Power Supply is indicated by state LED POWER. For correct function of the whole Plantyst Solution it is necessary to secure permanent power supply to the Box Input Connectors To connect the machines there are three-pole socket screw connectors (marked IN1 up to IN10). On each connector there is power supply of the box, on left and right side pins, marked + and. The voltage size and polarity correspond to size and polarity of the power supply of the Box (pins 1 and - od connectors IN1 to IN10 and POWER are connected inside between each other). If the polarity of the Box power supply is interchanged, the pins of connectors are interchanged. In such a case it may cause defect on sensors or on other equipment used for machine connection. The middle pin of the connector (marked SIG) id a digital power input designed for the signal from the machine. Value for the state of logical 1 is 7 28 V, for logical 0 od 0 3 V. Maximal input power is 28 V. Maximal frequency of the pulses is 1 khz. It is necessary to secured, that incoming signal does not contain interference, which could be considered as a valid pulse (which means pulses longer than 1ms). It is possible to minimalize the interference by use of shielded line, where shielding can be connected to minus of the connector. There are control LED above the connectors, signalizing the occurrence of logical state 1 on the input. 3

4 1.3. Other Connectors Ethernet (ETH): 10/100 Mbit/s Ethernet connected with connector RJ45 (8P8C) as standards IEEE Base-T, IEEE 802.3u 100Base-TX a IEEE 802.3x. USB: USB 2.0 designed for service purpose and configuration of computer network (see chapter Network Communication) 2. Installation Place the Box inside the cabinet, on dry place with temperature up to max. 60 C, with accest to the Box. Below is the Schema of the connection of the Box, using the GSM modem (picture 2) or direct through in-house network (picture 3). Consult the connection to the machine with your machine supplier. Picture 2 Connection Schema connection via GSM modem 4

5 Picture 3 Connection Schema Ethernet Cable 3. Network Communication 3.1. Communication and Data transfer between the Box and Plantyst servers Box communicates always in direction out. It does not require to open dedicated ports from internet into the in-house network. The Box communicates with following ways, that does not require any other special settings: Establish HTTPS connections with Plantyst servers on port 443, Establish HTTPS connections for transfer of new actualizations from Plantyst servers on port 80, Synchronizes time via NTP protocol on port 123. Internal network (its elements) may not block such communication, or the Box will not work correctly. If requested, it is possible to configure NTP client, so that the client communicates with its in-house NTP server. List of communications Endpoints: HTTP a HTTPS protokol api.plantyst.com NTP protokol 0.debian.pool.ntp.org 1.debian.pool.ntp.org 2.debian.pool.ntp.org 3.debian.pool.ntp.org PING

6 Endpoints of PING protocol are designed only for diagnostic of communication (see Chapter 3.3.). Their availability is not necessary within regular operation Setting of computer network Proper setting of computer network and configuration of network connection of the Box has crucial influence on Plantyst full functionality. Manufacturing companies use most often 3 types of network configurations. Type of network configuration will be told to you by your IT administrator. 1. Dynamic configuration with DHCP server no necessity to register MAC address. In this case no action is required. 2. Dynamic configuration with DHCP server necessity to register MAC address. In this case it is necessary to register the Box into the Computer Network. Hand over to your IT administrator the MAC address of the Box and ask him for registration. MAC address is on the card on the front panel of the box in a format type MAC: 00:05:AB:FF:00: Static configuration without DHCP. In this case it is necessary to configure the Box. Hand over the Box to your IT administrator and ask him to configure it according the following procedure. For configuration you need to know: MAC address of the BOx (see the card on front panel), IP address reserved for the Box, net mask, default gateway, DNS server (domain name server) Setup procedure Setup the Box (switch the network configuration to static without DHCP ) using the USB Flash disk and simple text file.. 1. Connect USB Flash disk formatted as FAT32 (Windows standard) to your computer. 2. Create text file according the following pattern: 6

7 IPADDR= NETMASK= GATEWAY= DNS= If you create the file make sure, that it does not contain windows type of end of line (CRLF), but only unix (LF). 3. Save prepared file under the name PLANTYST_IP_STATIC_copy (without suffix) on USB Flash disk. 4. Disconnect USB Flash disk from your computer and connect it to USB port of switched-off Box (switched-off from power supply). 5. Connect power supply to box and wait until the USB Flash disk stops to flash (ca 20 seconds). 6. Now you can switch-off the Box and disconnect the USB Flash disk - configuration is completed a saved. In case you need to change the static configuration, use the same steps - original configuration will be rewritten. pin case you need to reconfigure the Box back to dynamic network configuration, create empty file and save it to USB Flash disk under the name PLATYST_IP_STATIC_remove (without suffix). Further follow the steps 4, 5 and 6 above Diagnostic of communication It is possible to diagnose the state of communication with Plantyst servers by means of LED CONNECTED, on top side of the Box. Meaning in chart below: State LED Cause Disconnected UTP cable..... Short flashing at about 4 seconds Internet not available Short flashing at about 1 second Internet available Flashing with period ca 1 second Disconnected cable Servery do not answer to PING Connection to Plantyst servers is not available Successful connection with Plantyst servers 7

8 4. Device Security - Plantyst Box Security The device stores data from the monitored machines not longer than absolutely necessary. Data are safely sent to the servers. The device communicates encrypted over the Internet to the server side. Communication runs via HTTPS protocol with verification of SSL certificate of the server authority. The device does not contain any sensitive information, neither about the customer nor the machines, and thus cannot be exploited by any hacker, for example for a purpose to read data from another devices or to impersonation the system users. From this reason theft of the device does not pose any serious security risk. Designed one-way communication protocol makes mastering of the device from the outside by an unauthorized person impossible. Devices can be connected to the demilitarized zone (DMZ) of the customer, or directly to his internal network. 5. Technical specification of the Box Dimensions (w x h x d) Assembly Weight Current consumption without periphery Power voltage Micro PC mm Free or on DIN rail 35mm 0,9 kg typ. 200 ma at 12 V 12 to 28 V DC CPU: ARM MHz RAM: 512MB RAM Persistent memory: SD/microSD, 8GB This User Guide is property of the Plantyst s.r.o. Plantyst 2015 Plantyst s.r.o. Havlickova Kolin PLANTYST info@plantyst.com 8

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux S SENECA Z-PC Line EN Installation Manual Contents: - General specifications - Technical features - Modbus and CANopen connections - Installation rules - Electrical connections - LEDs signallings - Default

More information

EY-WS 500: Web server for moduweb Vision and moduweb500 BACnet networks

EY-WS 500: Web server for moduweb Vision and moduweb500 BACnet networks EY-WS 500: Web server for moduweb Vision and moduweb500 BACnet networks How energy efficiency is improved Monitor the operation of your building and recognise optimisation potential, wherever you are Features

More information

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term Characteristics Modbus TCPIP diagnostic expansion module with screw term Main Range of product Product or component type Device short name [Us] rated supply voltage Complementary Power dissipation in W

More information

QUICK-START EMU M-BUS CENTER ENGLISH

QUICK-START EMU M-BUS CENTER ENGLISH QUICK-START EMU M-BUS CENTER ENGLISH EN QUICK-START INSTRUCTIONS CONTENT INSTALLATION...3 Power supply...3 Network connection...4 Connect meter (M-BUS)...4 START-UP PROCEDURE...5 Default network configuration...5

More information

ROOM GUARD VT335. Environmental Infrastructure monitoring

ROOM GUARD VT335. Environmental Infrastructure monitoring Environmental Infrastructure monitoring ROOM GUARD VT335 Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more. Compatible with

More information

VT805 / Monitoring system

VT805 / Monitoring system Environmental Infrastructure monitoring VT805 / Monitoring system Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more. Compatible

More information

COMELIT AUDIO PLAYER ART

COMELIT AUDIO PLAYER ART COMELIT AUDIO PLAYER ART. 20004500-20004501 - 20004502 1 2 TABLE OF CONTENTS 1 INTRODUCTION... 4 1.1 OVERVIEW OF FUNCTIONS... 4 1.2 FUNCTIONAL PRINCIPLE... 4 2 COMELIT AUDIO PLAYER... 5 2.1 SERVER AND

More information

VT608 / Switched PDU with 8 outlets

VT608 / Switched PDU with 8 outlets Switched PDU with Monitoring VT608 / Switched PDU with 8 outlets Device is used for load management and allows to switch on/off or reboot up to 8 outlets. It has built-in temperature sensor, can connect

More information

Technical characteristics (MICA)

Technical characteristics (MICA) HARTING MICA CISS Complete IIoT Starter Kit - Data Sheet Advantages Technical characteristics (MICA) All hardware and software components included to start your industrial condition monitoring application

More information

ROOM GUARD VT335. Environmental Infrastructure monitoring

ROOM GUARD VT335. Environmental Infrastructure monitoring Environmental Infrastructure monitoring ROOM GUARD VT335 Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more. Compatible with

More information

TM258LF42DT compact base M I/O - 24 V DC - CANopen

TM258LF42DT compact base M I/O - 24 V DC - CANopen Characteristics compact base M258-42 I/O - 24 V DC - CANopen Main Range of product Product or component type Product specific application Discrete I/O number 42 Discrete output number Modicon M258 Logic

More information

Quick Installation Guide

Quick Installation Guide Quick Installation Guide DL-200 Cellular Data logger V1.2_201610 TABLE OF CONTENTS CHAPTER 1 INTRODUCTION... 4 1.1 CONTENTS LIST... 5 1.2 HARDWARE INSTALLATION... 6 1.2.1 WARNING... 6 1.2.2 SYSTEM REQUIREMENTS...

More information

Technical data. General specifications. Functional safety related parameters B 10d Electrical specifications Operating voltage U B

Technical data. General specifications. Functional safety related parameters B 10d Electrical specifications Operating voltage U B Model Number Cable pull rotary encoder with PROFI- NET interface Features Robust aluminum drum housing Drum travel when cable retracted using threaded spindle Bellows with steel tip Comprehensive accessories

More information

TM258LD42DT4L compact base M I/O - 24 V DC

TM258LD42DT4L compact base M I/O - 24 V DC Characteristics compact base M258-42 + 4 I/O - 24 V DC Main Range of product Product or component type Product specific application Discrete I/O number 42 Analogue input number 4 Discrete output number

More information

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision 1.03.00 Motortronics / Phasetronics 1600 Sunshine Drive Clearwater, Florida 33765 Tel: 727-573-1819 Fax: 727-573-1803

More information

Standard protocol support (e.g. MODBUS, SNMP, M-Bus), possibility to install dedicated user protocols

Standard protocol support (e.g. MODBUS, SNMP, M-Bus), possibility to install dedicated user protocols NPE9500 Programmable Programowalny automation kontroler automatyki controller (PAC) is the newest series of industrial computers which you can easily adapt to your needs by choosing from the available

More information

1 Port USB PS/2 Server Remote Control IP KVM Switch with Virtual Media. StarTech ID: SV1108IPEXT

1 Port USB PS/2 Server Remote Control IP KVM Switch with Virtual Media. StarTech ID: SV1108IPEXT 1 Port USB PS/2 Server Remote Control IP KVM Switch with Virtual Media StarTech ID: SV1108IPEXT The SV1108IPEXT 1 Port USB PS/2 Server Remote Control IP KVM Switch with Virtual Media lets you control a

More information

User Manual Anybus Serial Server

User Manual Anybus Serial Server User Manual Anybus Serial Server Rev. 1.20:1 HMS Industrial Networks AB Germany Japan Sweden U.S.A UK + 49-721 - 96472-0 + 81-45 - 478-5340 + 46-35 - 17 29 20 + 1-773 - 404-3486 + 44 (0) 1908-359301 ge-sales@hms-networks.com

More information

Ethernet/SIOX Gateway Applicable to firmware ver 1.0

Ethernet/SIOX Gateway Applicable to firmware ver 1.0 ES2 Ethernet/SIOX Gateway p 2 TELEFRANG AB TABLE OF CONTENTS Ethernet/SIOX Gateway Applicable to firmware ver 1.0 General Description The ES2 module is a Gateway between a LAN/WAN Ethernet network and

More information

VT825 / Environmental Monitoring unit. Environmental Infrastructure monitoring

VT825 / Environmental Monitoring unit. Environmental Infrastructure monitoring Environmental Infrastructure monitoring VT825 / Environmental Monitoring unit The unit is used for IT environmental control in data-centers, remote facilities, offices, industrial facilities & remote shelters.

More information

UTM Content Security Gateway CS-2001

UTM Content Security Gateway CS-2001 UTM Content Security Gateway CS-2001 Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Setup the UTM Content Security Gateway... 4 3. Hardware Installation... 5 4. Basic System Configuration...

More information

IP gateway, MDRC IG/S 1.1, GH Q R0001

IP gateway, MDRC IG/S 1.1, GH Q R0001 , GH Q631 0067 R0001 The IP gateway IG/S is the interface The IP address of the IG/S can be between EIB / KNX installations and IP fixed or received from a DHCP server. CDC 071 130 F0003 networks. Data

More information

TM251MESE. Main. [Us] rated supply voltage. 14 with remote I/O architecture W with max number of I/O expansion module

TM251MESE. Main. [Us] rated supply voltage. 14 with remote I/O architecture W with max number of I/O expansion module Product datasheet Characteristics TM251MESE Main Range of product Product or component type [Us] rated supply voltage Modicon M251 Logic controller 24 V DC Complementary Number of I/O expansion module

More information

VW3A3521S0 ATV IMC drive controller card type S solutions

VW3A3521S0 ATV IMC drive controller card type S solutions Product data sheet Characteristics ATV IMC drive controller card type S solutions Main Range of product Product or component type Module configuration Product specific application Discrete I/O number 16

More information

The TCMS Solution ionia Train control by duagon

The TCMS Solution ionia Train control by duagon ionia Train control by duagon The small, space-saving and innovative one-for-all solution with the complete duagon train communication and control expertise. The TCMS Solution Space-saving and powerful

More information

TM221CE24R controller M IO relay Ethernet

TM221CE24R controller M IO relay Ethernet Product data sheet Characteristics TM221CE24R controller M221 24 IO relay Ethernet Complementary Main Discrete I/O number 24 Number of I/O expansion module Supply voltage limits Network frequency Inrush

More information

WRM 247+ QUICK GUIDE

WRM 247+ QUICK GUIDE Copyright 1999-2017 WAPICE Ltd - All rights reserved We control the copyright in this document, and you may only use this document or parts of this document in accordance with the provisions in our terms

More information

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications IA260 Series Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA Features and Benefits Cirrus Logic EP9315 Arm9 CPU, 200 MHz 128 MB RAM onboard, 32 MB flash disk

More information

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS 18 channels for HART / Modbus RTU sensors 2 digital channels 16 math channels 4 relay outputs for alarm or control

More information

TG Technical specifications

TG Technical specifications TG2-500 Technical specifications TBox TG2-500 Specifications SPECIFICATIONS Standard: 3 wires 4G Modem -4E: Europe -4N: North America Backup battery charger TG2-500: COMMUNICATION PORTS TG2-500-4E: COMMUNICATION

More information

TM221ME32TK controller M IO transistor PNP Ethernet

TM221ME32TK controller M IO transistor PNP Ethernet Product data sheet Characteristics TM221ME32TK controller M221 32 IO transistor PNP Ethernet Complementary Main Discrete I/O number 32 Number of I/O expansion module Supply voltage limits Inrush current

More information

NetBiter Serial Server User Manual

NetBiter Serial Server User Manual User Manual IntelliCom Innovation AB Linjegatan 3D SE-302 50 Halmstad SWEDEN Phone +46 35 18 21 70 Fax +46 35 17 29 09 email info@intellicom.se web www.intellicom.se Revision List Revision Date Author

More information

AX3000 Platine Terminal Ethernet TCP/IP

AX3000 Platine Terminal Ethernet TCP/IP AX3000 Platine Terminal Ethernet TCP/IP Model 80WMS Installation Guide January 2012 - Ref: I80ME0922-2 Model AX3000/M80M Type EA The reproduction of this material, in part or whole, is strictly prohibited.

More information

1 Port USB PS/2 Server Remote Control IP KVM Switch with Virtual Media. StarTech ID: SV1108IPEXT

1 Port USB PS/2 Server Remote Control IP KVM Switch with Virtual Media. StarTech ID: SV1108IPEXT 1 Port USB PS/2 Server Remote Control IP KVM Switch with Virtual Media StarTech ID: SV1108IPEXT The SV1108IPEXT 1 Port USB PS/2 Server Remote Control IP KVM Switch with Virtual Media lets you control a

More information

TM241CE24T controller M IO transistor PNP Ethernet

TM241CE24T controller M IO transistor PNP Ethernet Product data sheet Characteristics TM241CE24T controller M241 24 IO transistor PNP Ethernet Complementary Main Discrete I/O number 24 Number of I/O expansion module Supply voltage limits Inrush current

More information

TM221CE40T controller M IO transistor PNP Ethernet

TM221CE40T controller M IO transistor PNP Ethernet Product data sheet Characteristics TM221CE40T controller M221 40 IO transistor PNP Ethernet Complementary Main Discrete I/O number 40 Number of I/O expansion module Supply voltage limits Inrush current

More information

TM221M16R controller M IO relay

TM221M16R controller M IO relay Product data sheet Characteristics TM221M16R controller M221 16 IO relay Complementary Main Discrete I/O number 16 Number of I/O expansion module Supply voltage limits Inrush current Power consumption

More information

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input. ProData DATA LOGGER Ethernet Pulse inputs and Pulse outputs Modbus-Ethernet gateway Thermistor input Memory 32 MB Threshold value monitoring 139 Smart and compact: Save energy costs through the universal

More information

Hardware manual. 1. Overview 2. Technical characteristics 3. Connections. ( Portal (../portal/portal.html)

Hardware manual. 1. Overview 2. Technical characteristics 3. Connections. (  Portal (../portal/portal.html) 1 (http://nethix.com) Portal (../portal/portal.html) WE110 (../we110/we110.html) WE120 (../we120/we120.html) WE300 (../we300/we300.html) WE500 (we500.html) Quick start guide (we500_qsg.html) Hardware manual

More information

Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more.

Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more. VT800 Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more. Compatible with all VT or SC sensors, it provides a complete environmental,

More information

Date Revision Change(s) 29/07/ First version

Date Revision Change(s) 29/07/ First version Revision overview Revision overview Date Revision Change(s) 29/07/2016 0 First version Copyright 2016 Indu-Sol GmbH We reserve the right to amend this document without notice. We continuously work on further

More information

STANDALONE INTERFACES USB-DMX 512 & 1024 CHANNELS V.1.1

STANDALONE INTERFACES USB-DMX 512 & 1024 CHANNELS V.1.1 STANDALONE INTERFACES USB-DMX 512 & 1024 CHANNELS V.1.1 SUMMARY Hardware technical specifications... 3 Front Face of the 512 / 1024 channels interfaces... 4 Side Faces of the 512 / 1024 channels interfaces...

More information

TM241CE40R controller M IO relay Ethernet

TM241CE40R controller M IO relay Ethernet Product data sheet Characteristics TM241CE40R controller M241 40 IO relay Ethernet Complementary Main Discrete I/O number 40 Discrete input logic Discrete input voltage Discrete input voltage type Voltage

More information

Accessories for the mobile Power Quality Analyzers PQ-Box 100 & 150 & 200

Accessories for the mobile Power Quality Analyzers PQ-Box 100 & 150 & 200 Accessories for the mobile Power Quality Analyzers PQ-Box 100 & 150 & 200 05-2017 Accessories for PQ-Box 100 & 150 & 200 Page 1 Rogowski coil set CAT IV 600V Current range: 1A to 3000A RMS; Accuracy: 1%

More information

The ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V.

The ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V. ECL Apex 20 controller and ECA 20 (ECL Apex Web Panel) Description ECL Apex 20 and ECA 20 ECL Apex 20 The ECL Apex 20 and the ECA 20 (ECL Apex Web Panel) are used in large district heating applications.

More information

PAS 300, PROFIBUS Slave Interface Module

PAS 300, PROFIBUS Slave Interface Module Catalog 08 PROFIBUS-Components 27 PAS 300, PROFIBUS Slave Interface Module PROFIBUS PROFIBUS slave interfaces PROFIBUS slave module The PROFIBUS slave interface module PAS 300 from the Systeme Helmholz

More information

Control Panel CP600-eCo CP604, CP604-B

Control Panel CP600-eCo CP604, CP604-B DATA SHEET Control Panel CP600-eCo CP604, CP604-B 1 Ordering Data Part No. Description Product Life Cycle Phase 1SAP504100R0001 CP604, control panel, TFT graphical display, single-touch screen, 4.3, Active

More information

Monitoring system LN-VT325. Environmental Infrastructure monitoring

Monitoring system LN-VT325. Environmental Infrastructure monitoring Environmental Infrastructure monitoring Monitoring system LN-VT325 Environmental monitoring of small facilities, access control, monitoring of tempertures, smoke, water leakages, voltages and more. Overview

More information

GV-AS200 Controller. Hardware Installation Guide

GV-AS200 Controller. Hardware Installation Guide GV-AS200 Controller Hardware Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2008 GeoVision, Inc.

More information

MANUAL NWAC7000. Wireless Management Platform

MANUAL NWAC7000. Wireless Management Platform MANUAL NWAC7000 Wireless Management Platform Contents Chapter 1 Manual Introduction... 4 Chapter 2:Product Introduction... 4 2.1 Products description... 4 2.2 Products Properties... 4 2.2.1Hardware Property...

More information

PLC PFC200 Controller PFC200 CS 2ETH RS

PLC PFC200 Controller PFC200 CS 2ETH RS 0-202 PLC PFC200 Controller PFC200 CS 2ETH RS Marking area Serial interface RJ-4 RJ-4 ACT X2 LNK ETH ACT X LNK X3 RS232/4 U U U4 U3 U2 U STOP RESET 0-202 SYS I/O MS NS U RST SD 0 02 A B 24V 0V + + Status

More information

Data sheet CPU 115 (115-6BL02)

Data sheet CPU 115 (115-6BL02) Data sheet CPU 115 (115-6BL02) Technical data Order no. 115-6BL02 Type CPU 115 General information Note - Features 16 (20) inputs 16 (12) outputs from which are 2 PWM 50 khz outputs 16 kb work memory,

More information

connecdim Gateway G1 Ethernet TCP/IP to DALI

connecdim Gateway G1 Ethernet TCP/IP to DALI Gateway G1 Ethernet TCP/IP to LI Independent lighting control for up to 256 LI gears on 4 LI lines Can be expanded by connecting multiple gateways on the same network Cloud based web interface for configuration

More information

WP4200 Platform. control systems. CPU module for WP42xx Systems and Concepts. High performing controller for all types of turbines

WP4200 Platform. control systems. CPU module for WP42xx Systems and Concepts. High performing controller for all types of turbines CPU module for WP42xx Systems and Concepts High performing controller for all types of turbines Safe operation in harsh environmental conditions Maintenance free - no fans and no replaceable batteries

More information

USB2.0 IDE & LANDISK External Enclosure

USB2.0 IDE & LANDISK External Enclosure USB2.0 IDE & LANDISK External Enclosure CONTENT User s Manual 1. Product Information.....................1 2. Product Specifications....................2 3. System requirements....................3 4.

More information

QUICKSTART Smart EnOcean Gateway DC-GW/EO-IP

QUICKSTART Smart EnOcean Gateway DC-GW/EO-IP QUICKSTART Smart EnOcean Gateway DC-GW/EO-IP Digital Concepts GmbH 27.07.2016 Contents 1. Introduction... 3 2. Functionality... 4 3. Package Contents... 4 4. Requirements... 5 5. Ports... 5 6. Mounting...

More information

Short Instructions CG-S / IP-Router

Short Instructions CG-S / IP-Router 1 General Information This device is designed and built in conformity with the latest technical rules at the time of its development and production, so it is safe to operate. Danger maybe presented by

More information

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 130 a at 40 C Mission Time (T M ) L 10

Technical data. General specifications. Linearity error ± 0.1 Functional safety related parameters MTTF d 130 a at 40 C Mission Time (T M ) L 10 Model Number Features Solid shaft 0 Bit multiturn Free of wear magnetic sampling High resolution and accuracy Mechanical compatibility with all major encoders with fieldbus interface Status LEDs Description

More information

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2.

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2. Product datasheet Characteristics TM241CEC24T Main Range of product Product or component type [Us] rated supply voltage Discrete input number Discrete output type Discrete output number Discrete output

More information

AX3000 Platine Terminal Ethernet TCP/IP

AX3000 Platine Terminal Ethernet TCP/IP AX3000 Platine Terminal Ethernet TCP/IP Model 80 Installation Guide January 2012 - Ref: I80E0922-2 Model AX3000/M80 Type EA The reproduction of this material, in part or whole, is strictly prohibited.

More information

BLUE LOG X-SERIES. Quick Start Guide. Version

BLUE LOG X-SERIES. Quick Start Guide. Version BLUE LOG X-SERIES Quick Start Guide Version 20170223 1 DEVICE OVERVIEW 1 LED: Power-supply status 2 LED: Device status 3 LED: Online status 4 USB port 5 Directional pad 6 OK button 7 ESC button 8 Display

More information

TM241CEC24R controller M IO relay Ethernet CAN master

TM241CEC24R controller M IO relay Ethernet CAN master Characteristics controller M241 24 IO relay Ethernet CAN master Main Range of product Product or component type [Us] rated supply voltage Nov 28, 2017 Modicon M241 Logic controller 100...240 V AC Discrete

More information

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2

NET101. RS232 / RS422 / RS485 to Ethernet Converter. User s Manual. Version 1.2 NET101 RS232 / RS422 / RS485 to Ethernet Converter User s Manual Version 1.2 Copyright Information Copyright 2004-2005, Mega System Technologies, Inc. All rights reserved. Reproduction without permission

More information

modunet292: novanet-ethernet interface

modunet292: novanet-ethernet interface SAUTER EY-modulo 2 PDS 96.015 en Product Data Sheet EY-BU292 : - interface How energy efficiency is improved SAUTER EY-modulo 2 integrated into familiar IP technology Areas of application Parameterisation

More information

Table of Contents. 1 Welcome. 2 Install your Access Point-I. 3 Using the Access Point-I

Table of Contents. 1 Welcome. 2 Install your Access Point-I. 3 Using the Access Point-I Table of Contents 1 Welcome Introducing the Avaya Wireless LAN 1-1 About the Access Point-I 1-2 Finding Information 1-3 2 Install your Access Point-I Overview 2-1 Verify Kit Contents 2-2 Write Down Product

More information

LevelOne FBR User s Manual. 1W, 4L 10/100 Mbps ADSL Router. Ver

LevelOne FBR User s Manual. 1W, 4L 10/100 Mbps ADSL Router. Ver LevelOne FBR-1416 1W, 4L 10/100 Mbps ADSL Router User s Manual Ver 1.00-0510 Table of Contents CHAPTER 1 INTRODUCTION... 1 FBR-1416 Features... 1 Package Contents... 3 Physical Details... 3 CHAPTER 2

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports / IO-Link Module, /IO-Link Module, IO-Link Master with 4 s fourfold IO-Link Master single in one housing Power supply of s out of AUX (or ) Figure Type Inputs digital 8x M 8x M 4 x + 4 x + Outputs digital

More information

Accessories for the mobile Power Quality Analyzers PQ-Box 100 & 150 & 200 & 300

Accessories for the mobile Power Quality Analyzers PQ-Box 100 & 150 & 200 & 300 Accessories for the mobile Power Quality Analyzers PQ-Box 100 & 150 & 200 & 300 Jun-18 Accessories for PQ-Box 100 & 150 & 200 & 300 Page 1 Rogowski coil set CAT IV 600V Current range: 1A to 3000A RMS,

More information

Ha-VIS mcon 3000 Next Generation Introduction and features

Ha-VIS mcon 3000 Next Generation Introduction and features Ha-VIS Next Generation Introduction and features Ha-VIS Next Generation es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features The fully Managed es of the

More information

1 Safety instructions. 2 Device components. 3 Function. Smart Control IP. Art. No. SC 1000 IP. Operating instructions

1 Safety instructions. 2 Device components. 3 Function. Smart Control IP. Art. No. SC 1000 IP. Operating instructions Smart Control IP Art. No. SC 1000 IP Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire or property

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring Ethernet Pulse inputs and Pulse outputs Modbus-Ethernet gateway Thermistor input Memory 32 MB Threshold value monitoring ProData data logger 1 Smart and compact: Save energy costs through the universal

More information

UMG 511. Class A EN UMG 511 Class A power quality analyzer. according to EN50160, IEEE 519, ITIC, IEC Areas of application

UMG 511. Class A EN UMG 511 Class A power quality analyzer. according to EN50160, IEEE 519, ITIC, IEC Areas of application UMG 511 Class A EN 50160 UMG 511 Class A power quality analyzer according to EN50160, IEEE 519, ITIC, IEC 61000-4-30 The UMG 511 power quality analyzer is particularly suitable for monitoring power quality

More information

Operating and mounting instructions

Operating and mounting instructions General Usage IPAS DALI Gateways bring together the crossfunctional KNX installation bus and the lighting control specific DALI-Bus (IEC 60929). Lights with cost-effective, digital DALI ECGs can therefore

More information

TM258LF42DT compact base M I/O - 24 V DC - CANopen

TM258LF42DT compact base M I/O - 24 V DC - CANopen Characteristics compact base M258-42 I/O - 24 V DC - CANopen Main Range of product Product or component type Product specific application - Discrete I/O number 42 Discrete output number Complementary Discrete

More information

TM221CE40R controller M IO relay Ethernet

TM221CE40R controller M IO relay Ethernet Characteristics controller M221 40 IO relay Ethernet Main Range of product Product or component type [Us] rated supply voltage Jan 6, 2019 Modicon M221 Logic controller 100...240 V AC Discrete input number

More information

CHAPTER 7 ADVANCED ADMINISTRATION PC

CHAPTER 7 ADVANCED ADMINISTRATION PC ii Table of Contents CHAPTER 1 INTRODUCTION... 1 Broadband ADSL Router Features... 1 Package Contents... 3 Physical Details... 4 CHAPTER 2 INSTALLATION... 6 Requirements... 6 Procedure... 6 CHAPTER 3 SETUP...

More information

CM597 Ethernet Communication Module

CM597 Ethernet Communication Module Ordering Data DATA SHEET CM597 Ethernet Communication Module 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 173 700 R0001 1SAP 373 700 R0001 CM597-ETH, communication module Ethernet

More information

Ethernet modules for length measurement, 24-bit 16/8/4 inductive transducers, LVDT, half-bridge

Ethernet modules for length measurement, 24-bit 16/8/4 inductive transducers, LVDT, half-bridge MSX-E3701 / MSX-E3700 Acquisition of 4, 8 or 16 inductive displacement transducers For half-bridge or LVDT transducers Trigger / synchro Degree of protection or IP 40 Cascadable More information on www.addi-data.com

More information

ELAN3-ALARM ETHERNET COMMUNICATOR

ELAN3-ALARM ETHERNET COMMUNICATOR E3-ALARM ETHERNET COMMUNICATOR User Manual v1.1 Compatibility: E3-ALARM v0.3 and up + ESIM364 v02.07.00 and up. E3-ALARM v0.4 and up + ET082 v01.12.00 and up; hardware version: ET082-30 and up. Main features:

More information

Cascade Sensor Installation Guide. Version 8.2 March 2009

Cascade Sensor Installation Guide. Version 8.2 March 2009 Cascade Sensor Installation Guide Version 8.2 March 2009 Trademarks Riverbed, the Riverbed logo, Riverbed Cascade, and Cascade are trademarks of Riverbed Technology, Inc. Intel is a registered trademark

More information

TM251MESC controller M251 Ethernet CAN

TM251MESC controller M251 Ethernet CAN Characteristics controller M251 Ethernet CAN Price* : 278.88 GBP Main Range of product Product or component type [Us] rated supply voltage Complementary Number of I/O expansion module Supply voltage limits

More information

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m Characteristics I/O distributed module OTB - Ethernet TCP/IP - 0..100 m Complementary Concept Port Ethernet Bus length Main Number of devices per segment 0...256 Communication service Web services Discrete

More information

User Manual Gateway component for EtherNet/IP

User Manual Gateway component for EtherNet/IP User Manual Gateway component for EtherNet/IP PR100066 1/7/2016 Table of Contents KUNBUS GmbH Table of Contents 1 General Information... 3 1.1 Disclaimer... 3 1.2 Notes Regarding this User Manual... 4

More information

SpiNN 3 System Diagram

SpiNN 3 System Diagram SpiNNaker AppNote SpiNN-3 DevBoard Page AppNote - SpiNN-3 Development Board SpiNNaker Group, School of Computer Science, University of Manchester Steve Temple - 4 Nov - Version. Introduction This document

More information

Absolute Encoders Multiturn

Absolute Encoders Multiturn The multiturn encoders 6 and 8, with interface and combined optical and magnetic sensor technology, offer a maximum resolution of 5 bits. These encoders are programmable via the Ezturn software. The hollow

More information

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client User Manual V1.0.0 Table of Contents Overview... 1 1.1. Specification... 1 1.2. Dimensions... 2 1.3. Connector pinouts... 3 1.4. Restoring factory default... 3 1.5. LED indicator... 3 1.6. CR1225 battery...

More information

smartden IP-WatchDog PING Restarter and Auto-Rebooter

smartden IP-WatchDog PING Restarter and Auto-Rebooter smartden IP-WatchDog PING Restarter and Auto-Rebooter User Manual Date: For firmware version: v1.21 / May 2017-1- Content smartden IP-WatchDog User Manual 1. Features... 3 2. Application examples... 4

More information

6GK6024-8GS Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RSG2000 managed

6GK6024-8GS Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEDCOM Ethernet Switches > RUGGEDCOM RSG2000 managed Automation Technology > Industrial Communication > Industrial Ethernet > RUGGEOM Ethernet Switches > RUGGEOM RSG2000 managed 6GK6024-8GS2.-... RUGGEOM RSG2488 Technical Data Product-type designation Product

More information

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 05/2009 MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES.

More information

We take care of it. Mobile Power Quality Analyzers. PQ-Box 100/150/200. Accessories

We take care of it. Mobile Power Quality Analyzers. PQ-Box 100/150/200. Accessories We take care of it. Mobile Power Quality Analyzers PQ-Box 100/150/200 Accessories Rogowski coil set Current range: 1 A to 3000 A RMS; Set of 4 pieces Accuracy: 1%; Size: 61 cm (24 ); Diameter = 194 mm

More information

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual Lantech IPES-0008-4 8 10/100TX with 4 PoE Injectors 24~48VDC Industrial Switch User Manual V1.00 Jun 2010 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital

More information

EVAcharge SE - Datasheet

EVAcharge SE - Datasheet EVAcharge SE - Datasheet Datasheet (valid for board revision V0R4 or higher) Document history Revision 1.0 2013-10-10 Initial release 1.1 2013-11-06 Typo corrections 1.2 2014-05-13 Removed serial IF 1.3

More information

ETHM-2. Ethernet Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

ETHM-2. Ethernet Module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel Ethernet Module ETHM-2 Firmware version 1.0 ethm2_en 09/08 SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 info@satel.pl www.satel.pl SATEL's goal is to continually improve

More information

Sauter Systems

Sauter Systems 96.692/1 EYZ 292:, interface The is a interface for connecting the CASE Suite/ programming tools and the various novapro software on the management level to the EY3600 system with in a local area network

More information

Quick Start Guide NETL ink Ethernet Gateways

Quick Start Guide NETL ink Ethernet Gateways Version en as of FW. Quick Start Guide NETL ink Ethernet Gateways www.helmholz.com Content. Introduction. Checking the Network Situation. Preparing the NETL ink. IP Address Settings on the PG/PC Network

More information

4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus

4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus 4.7 Digital Input/Output Module 16 digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 4 V DC, CS31 system bus 1 3 Advant Controller 31 I/O Unit ERR Test 4 1 Fig. 4.7-1: Digital input/output

More information

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number Fieldbus Gateway RS-232 to PROFINET EPGG001 Part Number Easy handling Gateway from RS-232/422/485 interfaces to PROFINET With two Industrial Ethernet ports Technical Data Electrical Data Supply Voltage

More information

Real-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller

Real-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller SEL-3530 Real-Time Automation Controller (RTAC) Powerful, reliable, and secure multifunction controller Versatile RTAC operates as a supervisory control and data acquisition (SCADA) remote terminal unit

More information