PAS 300, PROFIBUS Slave Interface Module

Size: px
Start display at page:

Download "PAS 300, PROFIBUS Slave Interface Module"

Transcription

1 Catalog 08 PROFIBUS-Components 27 PAS 300, PROFIBUS Slave Interface Module PROFIBUS PROFIBUS slave interfaces PROFIBUS slave module The PROFIBUS slave interface module PAS 300 from the Systeme Helmholz GmbH is used to connect digital and analog input/output modules to the PROFIBUS-DP. The module can be fixed to a mounting rack. Up to 12 modules can be connected to the PAS 300 (12 digital or max. 8 analog). The PAS 300 is linked into the hardware configurator of the programming system by a device master file. The PAS 300 interface module performs all communication of the modular I/O device with the master device on the PROFIBUS-DP. The inputs and outputs are assigned to the relevant master by configuration. The PAS 300 module supports all the input/output modules of the Systeme Helmholz GmbH and a wide range of modules of the same design from other manufacturers. PAS 300, PROFIBUS slave interface module Manual PAS 300, german/english AA AA02 Dimensions (LxWxH mm) 116 x 40 x 125 approx. 250 g Power supply Voltage DC 24 V Current consumption max. 625 ma Output voltage DC 5 V Output current at DC 5 V max. 1 A (to backplane) Profibus interface Transmission rate max. 12 MBit/s, autodetection Protocol PROFIBUS DP to EN Addressrange 128 Bytes for inputs 128 Bytes for outputs Module count max. 12 digital, 8 analog Connection male, SUB-D, Permissible ambient temperature - operating 0 C C - transport and storage -25 C C

2 28 PROFIBUS-Components Catalog 08 EasyConnect PROFIBUS-Connector EasyConnect PROFIBUS connector The new EasyConnect PROFIBUS connector from the Systeme Helmholz GmbH rounds off the range of bus connector products excellently. The new EasyConnect connectors feature quick-connect technology, making the stripping of bus conductors superfluous. The bus connectors are used to connect a PROFIBUS node to the PROFIBUS line. The connector is quick to install, and has a metallized housing and integrated terminating resistors. The Systeme Helmholz GmbH offers the new EasyConnect connector with a perpendicular cable outlet. Correct connection of the PROFIBUS cable can quickly be checked visually even after installation. PROFIBUS connector EasyConnect without prog. device connector 90 with prog. device connector BA BB50 The PROFIBUS connectors are also available in boxes containing 10 or 50 pieces. Programming device connector Order No BB50 Order No BA50 yes no Dimensions (LxWxH mm) 72 x 40 x 17 Outgoing cable approx. 40 g vertical outgoing cable suitable for fast-connect stripping tool Terminating resistor Resistor combination integrated and connectable with slide switch Transmission rate max. 12 Mbit/s Interfaces PROFIBUS station SUB-D connector, PROFIBUS cable FC standard cable Current consumption V DC (must come from connected equip.) Current consumption max ma Permissible ambient conditions - operating temperature 0 C C - transport/storage temperatur -25 C C - relative humidity max. 75% at +25 C Degree of protection IP 40

3 Catalog 08 PROFIBUS-Components 29 Bus Connector for PROFIBUS smaller dimension Bus connector for PROFIBUS with (l.) and without (r.) prog. device connector The compact design of the smaller dimensions bus connectors from the Systeme Helmholz GmbH makes them suitable for use with the new CPU types from Siemens. A slide switch sets whether the connector will be used as a node or end of segment. The switch can also be operated when the connector is plugged. The switch setting is clearly visible. The connector must be used as a node ( OFF ) when the incoming bus (A1, B1) and the outgoing bus (A2, B2) are to be interconnected. This deactivates the terminating resistors. The connector must be set as a segment end ( ON ), on the first and last (extreme) stations of the segment. In that case the terminating resistors are connected on the incoming bus, the outgoing bus is disconnected. Bus connector for PROFIBUS without prog. device connector 90 with prog. device connector 90 Stripping tool for PROFIBUS BA BB AA00 The PROFIBUS connectors are also available in boxes containing 10 or 50 pieces. Programming device connector Order No BB12 Order No BA12 yes no Dimensions (LxWxH mm) 64 x 40 x 17 Outgoing cable approx. 40 g vertical outgoing cable suitable for fast-connect stripping tool Terminating resistor Resistor combination integrated and connectable with slide switch Transmission rate max. 12 Mbit/s Interfaces PROFIBUS station SUB-D connector, PROFIBUS cable 4 terminals for wires up to 1.0 mm 2 Current consumption V DC (must come from connected equip.) Current consumption max ma Permissible ambient conditions - operating temperature 0 C C - transport/storage temperature -25 C C - relative humidity max. 75% at +25 C Degree of protection IP 40

4 30 PROFIBUS-Components Bus Connectors Angled and Axial for PROFIBUS Catalog 08 Bus connector 35 for PROFIBUS Axial bus connectors for PROFIBUS The axial and 35 bus connector for PROFIBUS is a further component in our range of connectors providing you with low-cost, compatible alternatives for your automation. The bus connectors are used to connect a PROFIBUS node to the PROFIBUS cable. The connector is quickly mounted and features integrated terminating resistors. The Systeme Helmholz GmbH offers the bus connector with an axial cable and 35 outlet and for transmission rates up to 12 Mbaud. Bus connector for PROFIBUS axial cable outlet 35 cable outlet, without prog. device connector 35 cable outlet, with prog. device connector CA BA BB41 The PROFIBUS connectors are also available in boxes containing 10 or 50 pieces. Dimensions 35, (LxBxH mm) 54 x 40 x 17 Dimensions axial, (LxBxH mm) 68 x 39,5 x 17 Outgoing cable, 35 angled outgoing cable Outgoing cable axial axial outgoing cable, suitable for fastconnect stripping tool Terminating resistor Resistor combination integrated and connectable with slide switch Transmission rate max. 12 Mbit/s Interfaces PROFIBUS station SUB-D connector, PROFIBUS cable 4 terminals for wires up to 1.0 mm² Current consumption DC V (must come from connected equip.) Permissible ambient conditions - operating temperature 0 C C - transport/storage temperature -25 C C - relative humidity max. 75% at +25 C Degree of protection IP 40

5 Catalog 08 PROFIBUS-Components 31 Bus Connector for PROFIBUS Bus connector for PROFIBUS with (l.) and without (r.) prog. device connector The bus connectors for PROFIBUS are a further building block to our assortment that offers you low-cost, compatible alternatives for your automation. The bus connectors are used to connect a PROFIBUS station to the PROFIBUS cable. The connector is quickly mounted and has integrated, connectable terminating resistors. The Systeme Helmholz GmbH offers the bus connector with a vertical outgoing cable, and for transmission rates up to 12 Mbaud. The bus connector is plugged directly onto the PROFIBUS interface (SUB-D connector, ) of the PROFIBUS stations. The PROFIBUS cables are connected using 4-way screw terminals. The cable can be prepared for connection using the fast-connect stripping tool from Siemens. Using a slide switch, you can set whether the connector is to be used as a node or segment end. The switch can also be operated when the connector is installed. The setting can be clearly seen. The connector must be operated in node setting ( OFF ) when the incoming bus (A1, B1) and the outgoing bus (A2, B2) are to be interconnected. The terminating resistors are then bypassed. The connector must be set as a segment end ( ON ), on the first and last (extreme) stations of the segment. In that case the terminating resistors are connected on the incoming bus, the outgoing bus is disconnected. The PROFIBUS connectors are available with a design for use in potentially explosive hazardous zone 2 ("Atex"). Bus connector for PROFIBUS without prog. device connector, Ex-Zone 2 with prog. device connector, Ex-Zone 2 without prog. device connector with spring connection technique with prog. device connector with spring connection technique Stripping tool for PROFIBUS BA BB BA BB AA00 Programming device connector Order No BB11 Order No BA11 yes no Dimensions (LxWxH mm) 65 x 48 x 16 Outgoing cable approx. 40 g vertical outgoing cable suitable for fast-connect stripping tool Terminating resistor Resistor combination integrated and connectable with slide switch Transmission rate max. 12 Mbit/s Interfaces PROFIBUS station SUB-D connector, PROFIBUS cable 4 terminals for wires up to 1,0 mm 2 Current consumption DC V (must come from connected equip.) Current consumption max ma Permissible ambient conditions - operating temperature 0 C C - transport/storage temperature -25 C C - relative humidity max. 75% at +25 C Degree of protection IP 40

6 32 PROFIBUS-Components Catalog 08 Repeater for MPI and PROFIBUS Dropcable PROFIBUS for PG Repeater for MPI and PROFIBUS The RS485 repeater connects two PROFIBUS or MPI bus segments in RS485 technology with max. 32 nodes, including repeaters. With it, transmission rates of 9.6 Kbps to 12 Mbps are possible. The transmission signals are regenerated and retransmitted by the repeater. The repeater can therefore be used to implement long PROFIBUS segments. Active PROFIBUS Dropcable for PG The active profibus dropcable from the Systeme Helmholz GmbH is used for a failure-free connection to an existing PROFIBUS net. The active line is not a radial line because of it`s integrated electronic. Commissioning aids: - Switch for disconnecting segments - Display of bus activity - Disconnection of a segment if terminating resistor has been wrongly connected - Terminating resistor for every segment - Error display on bus - Switch for disconnecting repeater functions Transmission rate 9,6 KBit/s 1000 m 19,2 KBit/s 1000 m 45,45 KBit/s 1000 m 93,75 KBit/s 1000 m 187,5 KBit/s 1000 m 500 KBit/s 400 m 1500 KBit/s 200 m 3000 KBit/s 100 m 6000 KBit/s 100 m KBit/s 100 m MPI-/PROFIBUS-Repeater Dropcable PROFIBUS for PG, 3 m max. Segment length AA BD00 Dimensions (LxWxH mm) 115 x 110 x 35 approx. 240 g Power supply Voltage DC 24 V Current consumption max. 120 ma at 24 V Segment connection 4x 2 terminal block Interface PG/OP PROFIBUS interface Transmission rate max. 12 Mbit/s autodetection Protocol PROFIBUS DP to EN Connection connection, SUB-D, Permissible ambient temperature - operating 0 C C - transport and storage -25 C C

7 Catalog 08 PROFIBUS-Components 33 Terminal Block for MPI and PROFIBUS The PROFIBUS segments can be disconnected by a switch. This action connects a terminating resistor combination. 5 V and 24 V is available at both connectors for supplying MPI and PROFIBUS devices (e.g. SSW7 or operator terminals). The MPI/PROFIBUS multiplexer can be mounted directly onto a DIN rail. Terminal block for MPI/PROFIBUS in a metal housing The MPI/PROFIBUS terminal block allows connection of up to two devices to an MPI or PROFIBUS network. Two SUB-D connectors are located in the housing of the MPI/PROFIBUS terminal block. Terminal block for MPI/PROFIBUS, in a metal housing MPV20 Dimensions (LxWxH mm) 115 x 110 x 35 approx. 230 g Power supply Voltage DC 24 V Current consumption max. 200 ma at 24 V PROFIBUS interface Transmission max. 12 Mbit/s Connection 2x female, SUB-D 4x 2 terminal Perm. ambient temperature - operating 0 C C - transport and storage -25 C C The MPI/PROFIBUS multiplexer permits connection of up to 3 devices to one MPI or PROFIBUS network. The MPI/PROFIBUS multiplexer has a 1.2 m long connecting cable that can be plugged directly into the MPI/PROFIBUS socket of the PLC, but also at any position in a MPI or PROFIBUS network. The PG socket is the only socket that has the full MPI pin assignment. That makes it possible to use direct operation on this socket via an MPI adapter ( SSW 7 or PC adapter ) with programming software. Multiplexer for MPI-/PROFIBUS This pin assignment is not relevant for operation of PROFIBUS devices. The MPI/PROFIBUS multiplexer is powered via the connection line to the CPU. If the terminal does not provide 24 V, it is possible to draw the 24 V from an external source. The 24 V connector for this purpose (green connector) is polarized. Terminal block for MPI/PROFIBUS MPV01 Dimensions (LxWxH mm) 105 x 54 x 30 approx. 135 g Power supply Voltage DC 24 V Current consumption max. 200 ma at 24 V PROFIBUS interface Transmission max. 12 Mbit/s Connection 3x female, SUB-D, Perm. ambient temperature - operating 0 C C - transport and storage -25 C C

8 34 PROFIBUS-Components Catalog 08 NETLink lite, Ethernet-Gateway for MPI/PROFIBUS NETLink lite PG/PC Programmable controller 2,5 m cable length Hub TCP / IP Straight RJ45 Application for the NETLink lite NETLink lite PG/PC NETLink lite, Ethernet-Gateway for MPI/PROFIBUS Installed in a SUB-D shell, it contains a complete field bus participant with a 10/100 Mbps Ethernet interface. It is connected directly to the field bus connector of a automation device and connects it to the next switch or hub via a Ethernet cable. The NETLink lite can be used both in an MPI and in a PROFIBUS network. The 24 volt power supply is drawn via the MPI/PROFI- BUS connection. The driver supplied, links the NETLink lite into the programming software. All programming functions are available. The crossover adapter permits direct connection of the NETLink lite to a laptop or PC without a hub or switch. If no S7 functions are needed, the NETLink lite without S7 driver can be used for OPC SCADA applications (OPC-Server see page 37). lite NETLink lite with S7-Switch NETLink lite without S7-Switch Crossover-adapter MPI MPI CROSS Dimensions (LxWxH mm) 65 x 48 x 16 approx. 150 g (incl. cable and connector) Power supply Voltage DC 24 V Current consumption 70 ma Ethernet Connection Standard Connector 2,5 m cable length Application for the NETLink lite Programmable controller Crossover-Adapter 10 Base-T 100 Base-TX RJ45 PLUG Transmission rate autodetection MPI Transmission rate max. 12 MBit/s Data link FDL frames Operating temperature 0 C to 55 C Indicators 2 LEDs, one of them 2- coloured, communication status

9 Catalog 08 PROFIBUS-Components 35 NETLink PRO Hub PG/PC NETLink PRO TCP / IP Straight RJ45 Programmable controller Application for the NETLink PRO Crossover-Adapter PG/PC NETLink PRO The new NETLink PRO from the Systeme Helmholz GmbH is integrated into the housing of an SSW7 MPI adapter. Its 1.2 m long connecting cable is plugged directly into the CPU of the programmable controller. The connection cable is designed as active line and does not affect the MPI or PROFIBUS. The second PG socket allows the connection of an additional device to the CPU of the programmable controller. The new NETLink PRO can also be connected to an external 24 V source as an option. On the control side, the NETLink PRO permits the full transmission rate of 12 Mbps via MPI and PPOFIBUS. The device automatically detects transmission rates of 10 Mbps or 100 Mbps of the TCP network. On the MPI, at least 8 connections and on the PC side at least 4 connections can be made with the NETLink PRO. The new NETLink PRO also features automatic baud rate detection and flexible configuration options such as DHCP and DNS. An Ethernet socket replaces the usual fixed Ethernet cable. This gives more flexibility with the connection. The MPI/PROFIBUS is galvanically isolated from the external DC 24 V power supply as it is from the Ethernet interface. A 3m ethernet-cable is included with the NETLink PRO. NETLink PRO Crossover-adapter PRO MPI CROSS Application for the NETLink PRO Dimensions (LxWxH mm) 105 x 54 x 30 approx. 250 g Power Supply Voltage DC +24 V ±25 % Current consumption max. 150 ma Communication interface Type 10 Base-T/100 Base-TX Connector RJ45 Transmission rate MPI/PROFIBUS Type Programmable controller NETLink PRO 10/100 MBit/s RS485 Transmission rate max. 12 MBit/s Connector SUB-D, with PG interface and terminating resistor Protocols FDL frames Operating temperature 0 C...60 C Indicators 3 LEDs, therefrom 2 two coloured

10 36 PROFIBUS-Components Catalog 08 NETLink USB PC USBinterface USB-connecting cable (included) NETLink-USB Programmable controller Application for NETLink USB NETLink USB The new NETLink USB is a real alternative to the PROFIBUS-PC slot-in card. Its 1.2 m long connecting cable is plugged directly into the CPU of the programmable controller. The connection cable is designed as active line and does not affect the MPI or PROFIBUS. The second PG socket allows the connection of an additional device to the CPU of the programmable controller. With the NETLink USB it is possible to implement a USB interface on the MPI/PROFIBUS for programming or visualization at the full transmission rate of up to 12 Mbps. It is also possible to implement up to 16 connections. The new NETLink USB is supplied by the USB bus but also has an optional DC 24 V supply and automatic baudrate detection. On the USB, protocols Fullspeed (12 Mbps) & Highspeed (480 Mbps) are supported. The MPI/PROFIBUS is galvanically isolated from the external DC 24 V power supply as it is from the USB interface. A 3m highspeed USB-cable is included with the NETLink USB. NETLink USB USB MPI11 Dimensions (LxWxH mm) 105 x 54 x 30 approx. 250 g Power Supply Voltage DC 24 V ±25 % / DC 5 V USB Current consumption max. 150 ma at DC 24 V / max. 500 ma at DC 5 V USB Communication interface Type USB 2.0 Connector USB-A Transmission rate 12 MBit / 480 MBit MPI/PROFIBUS Type RS485 Transmission rate max. 12 MBit/s Connector Protocols SUB-D, with PG interface and terminating resistor FDL frames Operating temperature 0 C...60 C Indicators 3 LEDs, therefrom 2 two coloured

EasyConnect PROFIBUS-Connector, 90

EasyConnect PROFIBUS-Connector, 90 32 Catalog 10 Bus Connectors Repeater Active Dropcable Terminal Block DP/DP Coupler Ethernet Gateways OPC Server Systeme Helmholz GmbH 91091 Großenseebach Phone: +49 9135 7380-0 Fax: +49 9135 7380-110

More information

Bus Connector for PROFIBUS, 90

Bus Connector for PROFIBUS, 90 Catalog 09 PROFIBUS 31 Bus Connector for PROFIBUS, 90 Integrated terminating-resistor 90 cable-outlet Small housing with (l.) and without (r.) prog. device connector The compact design of the bus connectors

More information

CAN 300 PRO, Communication Module

CAN 300 PRO, Communication Module 90 Communication Modules CAN 300 PRO, Communication Module Layer 2, 11 Bit and 29 Bit (CAN 2.0 A/B) on the module DIP switch for adress + baud rate Micro Memory Card for saving a project (optional) USB

More information

PROFIBUS. Connectors Repeaters FO Wireless system Communication

PROFIBUS. Connectors Repeaters FO Wireless system Communication PROFIBUS Connectors Repeaters FO Wireless system Communication PROFIBUS CONNECTORS 8 PROFIBUS connector overview ORIENTATION PRODUCT IMAGE WITHOUT PG WITH PG PAGE 90 700-972-0BA12 700-972-0BB12 9 90 diagnosis

More information

NETL ink gateways. Ethernet gateways WLAN gateways High-speed USB gateways

NETL ink gateways. Ethernet gateways WLAN gateways High-speed USB gateways NETL ink gateways Ethernet gateways WLAN gateways High-speed USB gateways ETHERNET NETL ink PRO PoE, PROFIBUS Ethernet gateway FEATURES RFC (ISO on TCP) CPU-to-CPU communication (with S-¹ and S-¹) (POE)

More information

10 Years. Gateways. System Components for Automation. Catalog.

10 Years. Gateways. System Components for Automation. Catalog. 10 Years Gateways System Components for Automation Catalog 14 www.helmholz.com 2 Have you seen our new TB20 catalog? The new TB20 distributed fieldbus I/O system by Systeme Helmholz was shaped by direct

More information

System Components for Automation. Catalog.

System Components for Automation. Catalog. System Components for Automation Catalog 15 www.helmholz.com 2 TB20 catalog 2 The TB20 distributed fieldbus I/O system is characterized by a variety of performance attributes for practical application.

More information

System components for automation technology. Catalog.

System components for automation technology. Catalog. System components for automation technology Catalog 17 www.helmholz.com 2 TB20, DISTRIBUTED FIELDBUS I/O SYSTEM In the TB20-3 catalog, you will find all information and ordering data in regard to our decentralized

More information

System Components for Automation Technology. Catalog.

System Components for Automation Technology. Catalog. System Components for Automation Technology Catalog 16 www.helmholz.com 2 TB20. Distributed Fieldbus I/O System In the TB20-3 catalog, you will find all information and ordering data in regard to our distributed

More information

MPI-BUS. Programming Adapter PPI-Cable Accessory RK512- and HMI-Adapter

MPI-BUS. Programming Adapter PPI-Cable Accessory RK512- and HMI-Adapter MPI-BUS Programming Adapter PPI-Cable Accessory RK512- and HMI-Adapter 70 MPI-Bus Catalog 11 SSW7, MPI-Programming Adapter Features Programming and visualization up to 115 kbaud MPI up to 187,5 kbps Power

More information

IE/PB LINK PN IO. PROFINET applications

IE/PB LINK PN IO. PROFINET applications IE/PB LINK PN IO PROFINET applications Protection of investment due to simple connection of PROFIBUS DP slaves to PROFINET IO controller Enables the use also in plants with PROFIsafe applications Independence

More information

PA ROUTERS. The following criteria can be applied when choosing the network transition:

PA ROUTERS. The following criteria can be applied when choosing the network transition: PA ROUTERS To create a smooth network transition between PROFIBUS DP and PROFIBUS PA, the SIMATIC product range offers two versions: the DP/PA coupler and the PA link. The following criteria can be applied

More information

System Components for Automation 10

System Components for Automation 10 Catalog 10 Catalog 10 English Catalog System Components for Automation 10 www.helmholz.com www.helmholz.com www.helmholz.com Systeme Helmholz GmbH 91091 Großenseebach Phone: +49 9135 7380-0 Fax: +49 9135

More information

Brief instruction. Version. 3en.

Brief instruction. Version. 3en. Brief instruction Version 3en www.helmholz.com Application and functional description The FLEXtra FO is primarily a normal PROFIBUS repeater with the capability of expansion by 2 (with FO-2) or 5 (with

More information

Data sheet VIPA CPU 214PG (214-2BE03)

Data sheet VIPA CPU 214PG (214-2BE03) Data sheet VIPA CPU 214PG (214-2BE03) Technical data Order. General information Note - 214-2BE03 VIPA CPU 214PG Features Work memory [KB]: 96 Interface [RJ45]: Ethernet PG/OP communication Interface [RS485]:

More information

SUBCON-PLUS-PROFIB...

SUBCON-PLUS-PROFIB... Fast connector for PROFIBUS systems Data sheet 101610_en_10 PHOENIX CONTACT 2017-03-27 1 Description The SUBCON-PLUS-PROFIB... D-SUB series is specifically designed for use in PROFIBUS systems up to 12

More information

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1. PSI-MODEM-/PB Broadband PROFIBUS extender, PROFIBUS leased line modem Data sheet 104396_en_03 1 Description PHOENIX CONTACT 2013-08-21 1.1 Features The PROFIBUS extender can be used to easily network PROFIBUS

More information

Data sheet VIPA CPU 214NET PG (214-2BT13)

Data sheet VIPA CPU 214NET PG (214-2BT13) Data sheet VIPA CPU 214NET PG (214-2BT13) Technical data Order. 214-2BT13 VIPA CPU 214NET PG General information Note - Features Work memory [KB]: 96 Integrated Ethernet CP 243 Interface [RJ45]: active

More information

PHOENIX CONTACT

PHOENIX CONTACT Fast connection connector for PROFIBUS systems Data sheet 101610_en_07 PHOENIX CTACT 2011-11-17 1 Description The D-SUB series SUBC-PLUS-PROFIB is specially designed for use in PROFIBUS systems up to 12

More information

Structure and Function

Structure and Function Communication processors Communication processors Structure and Function Communication processors for the connection of different target and source systems, such as via Ethernet to higher-level MES and

More information

Supplementary Components WirelessHART products

Supplementary Components WirelessHART products Overview Application The connects wireless HART field devices by radio to the Ethernet. On the radio side, the supports the WirelessHART standard and on the Ethernet side the TCP/IP and Modbus TCP communication.

More information

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway Technical Information Fieldgate Intelligent Ethernet/PROFIBUS gateway Application Fieldgate is a system component that provides an independent access route to a PROFIBUS network. It may be used in a variety

More information

Data sheet CPU 315SB/DPM (315-2AG12)

Data sheet CPU 315SB/DPM (315-2AG12) Data sheet CPU 315SB/DPM (315-2AG12) Technical data Order no. 315-2AG12 CPU 315SB/DPM General information Note - Features SPEED-Bus - SPEED7 technology 1 MB work memory Memory extension (max. 2 MB) PROFIBUS-DP

More information

Data sheet CC 03, Commander Compact (603-1CC21)

Data sheet CC 03, Commander Compact (603-1CC21) Data sheet CC 03, Commander Compact (603-1CC21) Technical data Order. Type 603-1CC21 CC 03, Commander Compact General information Note - Features Display: 2 x 20 characters Interface: MP²I User memory:

More information

Fieldbus slave modules w/o I/Os

Fieldbus slave modules w/o I/Os tem SLIO Fieldbus slave modules w/o I/Os tem 500S tem 300S tem 100V Order number Figure Type IM 053CAN, CANopen slave IM 053DN, DeviceNet slave IM 053DP, PROFIBUS-DP slave IM 053EC, EtherCAT slave General

More information

Data sheet SLIO CPU 015PN (015-CEFPR01)

Data sheet SLIO CPU 015PN (015-CEFPR01) Data sheet SLIO CPU 015PN (015-CEFPR01) Technical data Order no. 015-CEFPR01 Type SLIO CPU 015PN Module ID - General information Note - Features SPEED7 technology 256 kb work memory Memory extension (max.

More information

VersaMax IP Input Module

VersaMax IP Input Module Module is used to accept digital input signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature Storage temperature Operating/storage humidity 60mm

More information

Data sheet CPU 315SN/NET (315-4NE12)

Data sheet CPU 315SN/NET (315-4NE12) Data sheet CPU 315SN/NET (315-4NE12) Technical data Order no. 315-4NE12 CPU 315SN/NET General information Note - Features SPEED-Bus - SPEED7 technology 1 MB work memory Memory extension (max. 2 MB) PROFIBUS-DP

More information

Siemens AG ES AH02-0AE0 6ES BH02-0AE0 6ES CH02-0AE0

Siemens AG ES AH02-0AE0 6ES BH02-0AE0 6ES CH02-0AE0 CP 340 Overview The economical complete solution for serial communication via point-to-point links. 3 versions with different transmission interfaces: - RS 232C (V.24) - 20 ma (TTY) - RS 422/RS 48 (X.27)

More information

Data sheet CPU 315SN/NET (315-4NE12)

Data sheet CPU 315SN/NET (315-4NE12) Data sheet CPU 315SN/NET (315-4NE12) Technical data Order no. 315-4NE12 CPU 315SN/NET General information Note - Features SPEED-Bus - SPEED7 technology 1 MB work memory Memory extension (max. 2 MB) PROFIBUS-DP

More information

Quick Start Guide NETL ink Ethernet Gateways

Quick Start Guide NETL ink Ethernet Gateways Version en as of FW. Quick Start Guide NETL ink Ethernet Gateways www.helmholz.com Content. Introduction. Checking the Network Situation. Preparing the NETL ink. IP Address Settings on the PG/PC Network

More information

Data sheet VIPA CPU 115DP (115-6BL22)

Data sheet VIPA CPU 115DP (115-6BL22) Data sheet VIPA CPU 115DP (115-6BL22) Technical data Order no. Type 115-6BL22 VIPA CPU 115DP General information Note - Features Work memory [KB]: 16 Load memory [KB]: 24 Onboard 16x DI / 12x DO / 4x DIO

More information

PLC PFC200 Controller PFC200 CS 2ETH RS

PLC PFC200 Controller PFC200 CS 2ETH RS 0-202 PLC PFC200 Controller PFC200 CS 2ETH RS Marking area Serial interface RJ-4 RJ-4 ACT X2 LNK ETH ACT X LNK X3 RS232/4 U U U4 U3 U2 U STOP RESET 0-202 SYS I/O MS NS U RST SD 0 02 A B 24V 0V + + Status

More information

The PROFIBUS and PROFINET Company. COMbricks Modules. Copyright 2013 PROCENTEC. All rights reserved.

The PROFIBUS and PROFINET Company. COMbricks Modules. Copyright 2013 PROCENTEC. All rights reserved. Modules SCOPE Repeater Module Name 1 Channel RS 485 SCOPE Repeater Type 1 Order code 101 201210 Description 1 Channel RS 485 PROFIBUS SCOPE repeater module with integrated quality oscilloscope for 12 Mbps

More information

SSW7. User Manual. Adapter for MPI-Bus. Version:2 / HW: 1 / FW: 3.0 and higher. Order number of manual: VK21/en VK21

SSW7. User Manual. Adapter for MPI-Bus. Version:2 / HW: 1 / FW: 3.0 and higher. Order number of manual: VK21/en VK21 SSW7 Adapter for MPI-Bus 700-751-1VK21 User Manual Version:2 / 2009-03-20 HW: 1 / FW: 3.0 and higher Order number of manual: 700-751-1VK21/en Systeme Helmholz GmbH Hannberger Weg 2 D-91091 Großenseebach

More information

System Components for Automation. Catalog.

System Components for Automation. Catalog. System Components for Automation Catalog 12 www.helmholz.com 2 Catalog 12 How to contact us: Orders by phone: +49 9135 7380-0 Orders by fax: +49 9135 7380-490 Orders by email: orders@helmholz.de In the

More information

Data sheet CPU 315SN/PN ECO (315-4PN33)

Data sheet CPU 315SN/PN ECO (315-4PN33) Data sheet CPU 315SN/PN ECO (315-4PN33) Technical data Order no. 315-4PN33 CPU 315SN/PN ECO General information Note - Features SPEED-Bus - SPEED7 technology work memory PtP PROFINET controller integrated

More information

IM IM in the RS485 variants features: 9-pin Sub-D socket for connection to PROFIBUS DP

IM IM in the RS485 variants features: 9-pin Sub-D socket for connection to PROFIBUS DP IM 151-1 Design The IM 151-1 interface modules are directly snapped onto the standard mounting rail. IM 151-1 modules feature: DIP switch for setting the PROFIBUS DP station address (1 to 125) Diagnostics

More information

Siemens AG Network transitions. 8/2 Transition from Industrial Ethernet to WirelessHART 8/2 IE/WSN-PA LINK

Siemens AG Network transitions. 8/2 Transition from Industrial Ethernet to WirelessHART 8/2 IE/WSN-PA LINK Siemens AG 2010 Network transitions /2 Transition from Industrial Ethernet to WirelessHART /2 Siemens IK PI News January 2010 Network transitions Overview General data HART (Highway Addressable Remote

More information

Data sheet CPU 315SB/DPM (315-2AG12)

Data sheet CPU 315SB/DPM (315-2AG12) Data sheet CPU 315SB/DPM (315-2AG12) Technical data Order no. 315-2AG12 CPU 315SB/DPM General information Note - Features SPEED-Bus - SPEED7 technology 1 MB work memory Memory extension (max. ) PROFIBUS-DP

More information

Data sheet CPU 115 (115-6BL02)

Data sheet CPU 115 (115-6BL02) Data sheet CPU 115 (115-6BL02) Technical data Order no. 115-6BL02 Type CPU 115 General information Note - Features 16 (20) inputs 16 (12) outputs from which are 2 PWM 50 khz outputs 16 kb work memory,

More information

TIM 3V- IE ADVANCED. Function

TIM 3V- IE ADVANCED. Function TIM 3V- IE ADVANCED Function The TIM 3V-IE Advanced enables one or more SIMATIC S7-300 or control center PCs (e.g. SINAUT ST7cc or ST7sc) to exchange data with other SINAUT ST7 or ST1 stations via any

More information

Commander compact. Commander compact Lines displays. System SLIO. System 100V. Lines displays Commander compact 603-1CC CC21.

Commander compact. Commander compact Lines displays. System SLIO. System 100V. Lines displays Commander compact 603-1CC CC21. 0-CC 0-CC Order number 0-CC 0-CC Figure Type CC 0, Commander Compact CC 0DP, Commander Compact, PROFIBUS-DP slave General information Note - - Features x 0 characters, x 0 characters, Integrated PLC-CPU,

More information

SIMATIC NET. S7-CPs for PROFIBUS. CP Extended for PROFIBUS. Manual Part B4

SIMATIC NET. S7-CPs for PROFIBUS. CP Extended for PROFIBUS. Manual Part B4 SIMATIC NET S7-CPs for PROFIBUS Manual Part B4 CP 443-5 Extended for PROFIBUS 6GK7 443-5DX04-0XE0 Version 1 or higher (Firmware Version V6.1 or higher) for SIMATIC S7-400 / S7-400H Status and fault LEDs

More information

SSW7-RK512/RS422. Adapter for MPI Bus with RK512 Protocol, RS VK21. User Manual. Version: 1 / HW: 1 / FW: 2.

SSW7-RK512/RS422. Adapter for MPI Bus with RK512 Protocol, RS VK21. User Manual. Version: 1 / HW: 1 / FW: 2. SSW7-RK512/RS422 Adapter for MPI Bus with RK512 Protocol, RS422 700-752-5VK21 User Manual Version: 1 / 24.03.2009 HW: 1 / FW: 2.05 and later Order number of manual: 900-752-5VK21/en Systeme Helmholz GmbH

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

Data sheet VIPA CPU M13C (M13-CCF0000)

Data sheet VIPA CPU M13C (M13-CCF0000) Data sheet VIPA CPU M13C (M13-CCF0000) Technical data Order no. M13-CCF0000 Type VIPA CPU M13C Module ID - General information Note - Features Technical data power supply Power supply (rated value) Power

More information

modunet292: novanet-ethernet interface

modunet292: novanet-ethernet interface SAUTER EY-modulo 2 PDS 96.015 en Product Data Sheet EY-BU292 : - interface How energy efficiency is improved SAUTER EY-modulo 2 integrated into familiar IP technology Areas of application Parameterisation

More information

Manual Fiber Optic Interfaces

Manual Fiber Optic Interfaces Manual Fiber Optic Interfaces Type 81210, 81211 61210, 61211 65210, 65211 41210 Release 1.4 Subject to error and alteration 31 06/2007 by Wiesemann & Theis GmbH Subject to error and alteration: Since it

More information

Data sheet CPU 015PN (015-CEFPR00)

Data sheet CPU 015PN (015-CEFPR00) Data sheet CPU 015PN (015-CEFPR00) Technical data Order no. 015-CEFPR00 CPU 015PN Module ID - General information Note - Features Technical data power supply Power supply (rated value) Power supply (permitted

More information

CP BACNET Function

CP BACNET Function CP 343-1 BACNET Function The CP 343-1 BACnet independently handles data traffic via Industrial Ethernet and BACnet protocol. The module has its own processor and can be put into service directly using

More information

Quick Start Guide PN/CAN Gateway Layer 2. Version. 2 en. ab FW

Quick Start Guide PN/CAN Gateway Layer 2. Version. 2 en. ab FW Version 2 en ab FW 1.02 Quick Start Guide PN/CAN Gateway Layer 2 www.helmholz.de Content 1. Introduction 3 2. Preparation of the PN/CAN Gateway 3 3. Configure PN/CAN Gateway 4 4. PN/CAN Gateway settings

More information

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module Installation and Setup 1 2 In This Chapter.... Installing the H0 PSCM The Profibus Network Configuring the Module 2 2 Installing the H0 PSCM Remove the Slot Cover The first step in installing the option

More information

Data sheet CPU 015PN (015-CEFPR01)

Data sheet CPU 015PN (015-CEFPR01) Data sheet CPU 015PN (015-CEFPR01) Technical data Order no. Module ID - General information Note - Features Technical data power supply 015-CEFPR01 CPU 015PN Powered by SPEED7 Work memory [KB]: 256...512

More information

General information. Supply voltage

General information. Supply voltage Data sheet SIMATIC S7-300, CPU 313C-2DP COMPACT CPU WITH MPI, 16 DI/16 DO, 3 FAST COUNTERS (30 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 128 KBYTE WORKING MEMORY, FRONT CONNECTOR (1

More information

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual. INTERBUS Inline Bus Coupler; Remote Bus Connections Via D-SUB Connectors REMOTE IN BA UL RD RC DSUB LD AUTOMATIONWORX Data Sheet 6362_en_03 PHOENIX CONTACT - 11/2007 REMOTE OUT Description The bus coupler

More information

PSI-MOS-PROFIB/FO 850 T

PSI-MOS-PROFIB/FO 850 T Extract from the online catalog PSI-MOS-PROFIB/FO 850 T Order No.: 2708261 FO converter with integrated optical diagnosis, alarm contact, for PROFIBUS up to 12 MBit/s, T-coupler with two FO interfaces

More information

MGate 5102-PBM-PN Series

MGate 5102-PBM-PN Series MGate 5102-PBM-PN Series 1-port PROFIBUS-to-PROFINET gateways Features and Benefits Protocol conversion between PROFIBUS and PROFINET Supports PROFINET IO device Supports PROFIBUS DP V1 master Automatic

More information

Why can you not transfer the HMI configuration to the panel? - PROFIBUS Connection - FAQ 03/2014

Why can you not transfer the HMI configuration to the panel? - PROFIBUS Connection - FAQ 03/2014 FAQ 03/2014 Why can you not transfer the HMI configuration to the panel? - PROFIBUS Connection - http://support.automation.siemens.com/ww/view/en/88633853 This entry is from the Siemens Industry Online

More information

Controllers CECC Key features

Controllers CECC Key features Key features Application Controller State-of-the-art programming The controllers CECC are modern, compact and versatile controllers that enable programming with CODESYS according to IEC 61131-3. CODESYS

More information

CPU module for zone 2 Series 9442/35

CPU module for zone 2 Series 9442/35 > Supports PROFIBUS DP, PROFINET, Modbus TCP and Ethernet/IP; incl. HART transmission > RS-485 (max. 12 Mbps) and Ethernet (max. 100 Mbps) interfaces > Extensive diagnostics based on NE 107 > Support of

More information

SSW7-USB. User Manual VK21. Edition 3 / HW 6a and FW 3.29 and higher. Order number of manual: VK21/en

SSW7-USB. User Manual VK21. Edition 3 / HW 6a and FW 3.29 and higher. Order number of manual: VK21/en SSW7-USB 700-755-1VK21 User Manual Edition 3 / 10.10.2010 HW 6a and FW 3.29 and higher Order number of manual: 900-755-1VK21/en Systeme Helmholz GmbH Hannberger Weg 2 91091 Grossenseebach Phone: +49 9135

More information

Quick Start Guide PN/CAN-Gateway. Version. 1 en. from FW

Quick Start Guide PN/CAN-Gateway. Version. 1 en. from FW Quick Start Guide PN/CAN-Gateway Version 1 en from FW 1.00 www.helmholz.com Content 1. Introduction 3 2. Preparation of the PN/CAN-Gateway 3 3. Plan PN/CAN-Gateway 4 4. Configure PN/CAN-Gateway 5 5. Add

More information

CP ADVANCED. Function

CP ADVANCED. Function CP 343-1 ADVANCED Function The CP 343-1 Advanced independently handles data traffic over Industrial Ethernet. The module has its own processor and can be put into service directly using the unique preset

More information

Programmable Set for Simple I/O Communication via PROFIBUS-DP in IP67 TI-BL67-PG-DP-S-8

Programmable Set for Simple I/O Communication via PROFIBUS-DP in IP67 TI-BL67-PG-DP-S-8 Type designation Ident no. 1545097 Number of channels 8 Dimensions (W x L x H) 204 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 12 Mbps

More information

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018

More information

INDUSTRIAL COMMUNICATION AND INFRASTRUCTURE for your PROFINET application

INDUSTRIAL COMMUNICATION AND INFRASTRUCTURE for your PROFINET application INDUSTRIAL COMMUNICATION AND INFRASTRUCTURE for your PROFINET application www.helmholz.de MAC: ----- FCN RST Ext. V DC 8... V + FE IN IN PWR RUN BF SF Helmholz TB-C PROFINET IO Helmholz TB-C PROFINET IO

More information

MGate 4101-MB-PBS Series

MGate 4101-MB-PBS Series MGate 4101-MB-PBS Series 1-port Modbus RTU/ASCII-to-PROFIBUS slave gateways Features and Benefits Protocol conversion between Modbus and PROFIBUS Supports PROFIBUS DP V0 slave Supports Modbus RTU/ASCII

More information

Technical Information Fieldgate SFG500

Technical Information Fieldgate SFG500 TI00029S/04/EN/10.16 71324508 Products Solutions Services Technical Information Fieldgate SFG500 Smart Ethernet/PROFIBUS gateway Parallel access to PROFIBUS networks Monitoring of PROFIBUS and HART device

More information

Profibus-DPV1 Set in IP67 TI-BL67-DPV1-6

Profibus-DPV1 Set in IP67 TI-BL67-DPV1-6 Type designation Ident no. 1545030 Number of channels 6 Dimensions (W x L x H) 172 x 145 x 77.5 mm Cable max. 50 m between interface and read/write head 3 decimal rotary coding switches for the adjustment

More information

SIMOTION P PC-based SIMOTION P350-3

SIMOTION P PC-based SIMOTION P350-3 is a PC-based Motion Control system. In comparison to the previous version, the performance has been doubled. It is now possible to control machines with more than 40 axes in cycles of 2 ms. The operating

More information

Quick Connectors for PROFIBUS SUBCON-PLUS-PROFIB/...

Quick Connectors for PROFIBUS SUBCON-PLUS-PROFIB/... Quick Connectors for PROFIBUS SUBC-PLUS-PROFIB/.... Description The new SUBC-PLUS-PROFIB/... SUB-D series has been specifically designed for use in PROFIBUS systems up to 2 Mbps. It enables convenient

More information

Programmable Set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable Set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type designation Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100

More information

Features and Benefits. Certifications

Features and Benefits. Certifications MGate 5111 Series 1-port Modbus/PROFINET/EtherNet/IP to PROFIBUS slave gateways Features and Benefits Protocol conversion between Modbus, PROFINET, EtherNet/IP, and PROFIBUS Supports PROFIBUS DP V0 slave

More information

Technical Description

Technical Description B Content 1. Allgemeines...1 2. Blockdiagramm...2 3. Inbetriebnahme...2 4. Technische Daten...3 4.1 AS-Interface...3 4.2 Anschlussbelegung...3 4.3 LED Anzeige...4 4.4 Mechanische und Umgebungsdaten...4

More information

XC-CPU-201 XC-CPU-201-XV

XC-CPU-201 XC-CPU-201-XV / XC-CPU- XC-CPU--XV Ethernet integrated The / MBit Ethernet interface of the XC offers the perfect link to IT communication. Whether you need rapid access to programs, high-speed data exchange between

More information

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory. Product data sheet SIMATIC S7-300, CPU 314C-2DP COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO, 1 PT100, 4 FAST COUNTERS (60 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 64 KBYTE WORKING

More information

VersaMax* IC200BEM003. PROFIBUS Master Module. Ordering Information. Specifications. GFK-2739 April of their respective owners.

VersaMax* IC200BEM003. PROFIBUS Master Module. Ordering Information. Specifications. GFK-2739 April of their respective owners. April 2012 The VersaMax * IC200BEM003 PROFIBUS Master Module allows a VersaMax CPU005, CPUE05 or PROFINET Scanner (PNS) to send and receive data on a PROFIBUS-DP V1 network. The PROFIBUS Master module

More information

Sauter Systems

Sauter Systems 96.692/1 EYZ 292:, interface The is a interface for connecting the CASE Suite/ programming tools and the various novapro software on the management level to the EY3600 system with in a local area network

More information

Product type designation. General information. Supply voltage

Product type designation. General information. Supply voltage Data sheet SIMATIC S7-300, CPU 313C-2DP COMPACT CPU WITH MPI, 16 DI/16 DO, 3 FAST COUNTERS (30 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 128 KBYTE WORKING MEMORY, FRONT CONNECTOR (1

More information

User manual Compact Web PLC WP240 series IEC-line. update:

User manual Compact Web PLC WP240 series IEC-line. update: User manual Compact Web PLC WP240 series IEC-line update: 16-06-2017 IEC-line by OVERDIGIT overdigit.com 1. General description The WP240 device is a PLC, programmable in IEC61131-3 language using CoDeSys

More information

Technical data. General specifications. Functional safety related parameters B 10d Electrical specifications Operating voltage U B

Technical data. General specifications. Functional safety related parameters B 10d Electrical specifications Operating voltage U B Model Number Cable pull rotary encoder with PROFI- NET interface Features Robust aluminum drum housing Drum travel when cable retracted using threaded spindle Bellows with steel tip Comprehensive accessories

More information

Installation and Setup

Installation and Setup Installation and Setup 1 In This Chapter Installing the H PBC The Profibus Network Configuring the Controller Installing the H PBC Setting the Node Address Setting the Node Address Profibus DP is usually

More information

PAC BI-DP BIM and 8701-CA-BI Carrier

PAC BI-DP BIM and 8701-CA-BI Carrier June 2013 PAC8000 8507-BI-DP BIM and 8701-CA-BI Carrier PROFIBUS DP Bus Interface Module and Carrier The 8507-BI-DP Bus Interface Module (BIM) provides the communications link between the PAC8000 series

More information

Supplementary Components Network transitions

Supplementary Components Network transitions Siemens AG 201 Overview Benefits PROFINET applications Protection of investment due to simple connection of PROFI- BUS DP slaves to PROFINET IO controller Also enables use in plants with PROFIsafe applications

More information

Manual Industry Interfaces

Manual Industry Interfaces Manual Industry Interfaces W&T Release. Type 0, 0 0, 00 0, 0 0, 0 Industry Interfaces 0/0 by Wiesemann & Theis GmbH Subject to errors and changes: Since we can make mistakes, none of our statements should

More information

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description I/O extension module with 8 digital inputs or 2 pulse inputs INTERFACE Data sheet 0483_en_00 PHOENIX CONTACT 203-04-05 Description The I/O extension module can be used in conjunction with Radioline wireless

More information

Complete the Installation SKINTOP MS-SC. Color Code: Approvals: Nominal Outer Diameter

Complete the Installation SKINTOP MS-SC. Color Code: Approvals: Nominal Outer Diameter BUS UNITRONIC BUS PB For PROFIBUS-DP/FMS/FIP bus systems; stationary applications; 150 Ω UNITRONIC BUS PB UNITRONIC BUS PB FC UNITRONIC BUS PROFIBUS cables are designed for automation networks requiring

More information

BMS-Ethernet-Gateway COM460IP

BMS-Ethernet-Gateway COM460IP BMS-Ethernet-Gateway TDB501015en / 11.2012 BMS-Ethernet-Gateway BMS-Ethernet-Gateway Device features Modular, expandable gateway between BMS bus and TCP/IP Gateway between BMS bus and Ethernet Range of

More information

Manual. Profi-S-Link. Document 26/834; Edition EN

Manual. Profi-S-Link. Document 26/834; Edition EN Manual Profi-S-Link Document 26/834; Edition EN03 2013-10-17 Content 0 Content 0 Content 0.1 Document History... 0-2 0.2 About this manual... 0-2 0.3 Brands and trademarks... 0-2 0 1 Quickstart 1.1 Summary...

More information

Product and Application Description

Product and Application Description Technical Product-Information Product and Application Description The IP Gateway KNX-BACnet N 143 is is a DIN rail mounted device connecting a KNX installation with a system using BACnet/IP communication.

More information

Product type designation. General information. Supply voltage. Input current

Product type designation. General information. Supply voltage. Input current Data sheet SIMATIC S7-300, CPU 312C COMPACT CPU WITH MPI, 10 DI/6 DO, 2 FAST COUNTERS (10 KHZ), INTEGRATED 24V DC POWER SUPPLY, 64 KBYTE WORKING MEMORY, FRONT CONNECTOR (1 X 40PIN) AND MICRO MEMORY CARD

More information

POINT I/O Family. Chapter. Overview

POINT I/O Family. Chapter. Overview Chapter 1 POINT I/O Family Overview The POINT I/O family has modular I/O modules that are ideal for applications where flexibility and low-cost of ownership are key for successful control system design

More information

Extruder Controls ExtruVision S

Extruder Controls ExtruVision S Extruder Controls ExtruVision S ExtruVision S - The compact system solution for controlling, visualization, and operating extrusion systems Combination of control panel BA Touch with 5.7'' monitor and

More information

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet Fieldline Modular Device With Eight Digital Inputs Data Sheet 697000 02/2004 This data sheet is only valid in association with the FLS FLM SYS INST UM E user manual or the user manual for your bus system

More information

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision 1.03.00 Motortronics / Phasetronics 1600 Sunshine Drive Clearwater, Florida 33765 Tel: 727-573-1819 Fax: 727-573-1803

More information

System Components for Automation. Catalog.

System Components for Automation. Catalog. System Components for Automation Catalog 13 www.helmholz.com 2 How to contact us Orders by phone: +49 9135 7380-0 Orders by fax: +49 9135 7380-490 Orders by email: orders@helmholz.de In the Internet Homepage:

More information

PSI-MODEM-SHDSL/SERIAL

PSI-MODEM-SHDSL/SERIAL PSI-MODEM-/SERIAL -SERIAL permanent line modem Data sheet 104460_en_02 PHOENIX CONTACT 2011-12-06 1 Description The industrial SERIAL permanent line modem enables broadband networking of serial devices

More information

SCE Training Curriculum for Integrated Automation Solutions Totally Integrated Automation (TIA)

SCE Training Curriculum for Integrated Automation Solutions Totally Integrated Automation (TIA) SCE Training Curriculum for Integrated Automation Solutions Totally Integrated Automation (TIA) Siemens Automation Cooperates with Education TIA Portal Module 060-010 PROFIBUS with Master CPU 315F-2 PNDP

More information

RS-485 Products. ICP Electronics Australia Pty Ltd Communication Cards for PC/IPC P 2-1

RS-485 Products. ICP Electronics Australia Pty Ltd Communication Cards for PC/IPC P 2-1 2.1 Communication Cards for PC/IPC P 2-1 2.2 Communication Modules for PAC P 2-2 2.3 Converter/Repeater/Hub/Splitter P 2-3 2.4 Termination Resistor/DC Bias Voltage P 2-5 2.5 I/O Modules P 2-6 2.6 I/O Units

More information