NS

Size: px
Start display at page:

Download "NS"

Transcription

1 NS0-157 Number: Passing Score: 800 Time Limit: 120 min File Version: 1.0 Netapp Exam NS0-157 NetApp Certified Data Administrator, Clustered Data ONTAP

2 Экзамен A QUESTION 1 What communication link is necessary in order to establish an inter-cluster relationship? A. The cluster interface on each node must be able to communicate with the intercluster interface on each node in the both the source and destination clusters B. The cluster interface on the source cluster must be able to communicate with the cluster interface on the destination cluster C. The intercluster interface on the source cluster must be able to communicate with the intercluster interface on the destination cluster D. The intercluster interface on the source cluster must be able to communicate with the cluster interface on the destination cluster Correct Answer: C : QUESTION 2 A customer created a volume with the wrong language code. What should a customer do to correct this problem? A. Delete the volume and create a volume with the correct language code. B. Take the volume offline and change the language code. C. Change the language code on the volume. D. Change the language code on the parent storage virtual machine.

3 Correct Answer: A QUESTION 3 To achieve high-availability within a FAS8080 EX HA pair, which two requirements are needed? (Choose two.) A. Connect the NVRAM HA interconnects of the HA pairs. B. Connect multiple paths from the controllers to the host. C. Connect the local node to the partner node's disk shelves. D. Enable auto-giveback. Correct Answer: AB QUESTION 4 A customer has a 4-node cluster. Two nodes have FlashCache and the other two nodes have Flash Pools. The customer is interested in deploying and OLTP application with a workload that consists of an extreme number of small random writes on four LUNs spread across four volumes. What should the customer do to improve performance for the OLTP application? A. Place all volumes for the application on the nodes with Flash Pools. B. Deploy all volumes for the application on the two nodes with the FlashCache installed. C. Split the volumes between the two nodes with FlashCache and two of the nodes with Flash Pools.

4 D. Place the volume with the highest read load on the Flash Pool nodes and place the other volumes on the FlashCache nodes. Correct Answer: B QUESTION 5 Which NetApp management tool configures AutoSupport for nodes in a cluster? A. OnCommand System Manager B. ConfigAdvisor C. OnCommand Performance Manager D. OnCommand Insight Correct Answer: A QUESTION 6 A company has a vault relationship between ClusterA and ClusterB. After a month of operations, the SnapVault update fails. The primary and secondary volumes have been thin provisioned and are reporting available space. There is connectivity between ClusterA and ClusterB. What caused the update failure? A. The primary volume's aggregate is full. B. The secondary volume's aggregate is full. C. A cluster peering relationship was not refreshed every month.

5 D. There are 251 Snapshot copies on the destination SnapVault. Correct Answer: D QUESTION 7 A customer requires a solution that will provide site-level and local failover recovery with support for SMB 3.0. Which solution accomplishes this requirement? A. 2-node switchless cluster B. Fabric MetroCluster C. Stretch MetroCluster D. 8-node cluster Correct Answer: B QUESTION 8 Which command would you use to disable an account in clustered Data ONTAP? A. security login lock B. security login policy C. security login domain-tunnel D. security login modify Correct Answer: A

6 : Run the following command to disable the diag account for clustered Data ONTAP:security login lock diag Reference: alse QUESTION 9 A customer wants to use a UTA2 PCIe card in a new FAS8000 system. Which three steps must be completed before the customer is able to use the ports for Fc access to an FCP switch? (Choose three.) A. Use the system hardware unified-connect modify command to change the personality from initiator to target. B. Verify the WWPN of the UTA2 so that these can be used in the igroup to map the LUNs for host access. C. Verify that the correct SFP+ is installed for FC. D. Verify the card's hardware configuration by running the system hardware unifiedconnect show command. E. Verify that Data ONTAP iscsi, GIFS, and NFS are licensed on the system. Correct Answer: ACD Reference: EF-B90D-0A7DF498F71B.html QUESTION 10

7 A customer creates four broadcast domains with the following ports included for node cl-01: bcast1 e0c bcast2 e0d bcast3 e0e bcast4 e0f A customer creates a LIF and specifies a home port of cl-01:e0f. After LIF creation, the administrator modifies the home port to use cl-01:e0c. Which broadcast domain is the LIF using now? A. bcast4 B. bcast2 C. bcast1 D. bcast3 Correct Answer: C QUESTION 11 A NetApp cluster is connected to two network switches for resiliency. One of the network switches loses power. Most LIFs on the cluster automatically recover from the switch failure to and are reachable through the network. One LIF used for CIFS access is not reachable through the network until power is restored to the failed switch. Which two areas should be investigated to determine the problem? (Choose two.)

8 A. The protocols allowed on the LIFs. B. The LIFs failover-group configuration. C. The LIFs home port. D. The broadcast domain's member ports. Correct Answer: BD QUESTION 12 A customer has two SVMs joined to separate Active Directory domains. SVM1 is joined to domain AD1 and SVM2 is joined to domain AD2. The administrator enables Active Directory access to allow certain domain users access to the cluster using their Active Directory credentials. After enabling, some users report the inability to log into the cluster using their Active Directory credentials. What are three reasons this happened? (Choose three.) A. The user account belongs to the domain that is not used for cluster access authentication. B. The cluster time is off by two minutes from the Active Directory time server. C. The authentication tunnel was deleted and access sessions were disconnected. D. The Active Directory user account is not added to the cluster as a user. E. The user is not a member of an Active Directory group that is allowed access to the cluster. Correct Answer: ADE QUESTION 13

9 What will the storage aggregate create aggregate aggr0_rg0 diskcount 40 maxraidsize 20 nodes cl-01 disktype SAS command do? A. It creates a new aggregate named aggr0_rg0 with two RAID-DP RAID groups of 20 SAS drives on cl-01. B. It creates a new aggregate named aggr0_rg0 with one RAID-DP RAID group of 40 SAS drives on cl-01. C. It creates a new aggregate named aggr0_rg0 with two RAID4 RAID groups of 20 SAS drives on cl-01. D. It creates a new aggregate named aggr0_rg0 with two RAID4 RAID groups of 20 SAS drives on cl-02. Correct Answer: A QUESTION 14 When you use the volume snapshot autodelete command, what are three values for the commitment parameter? (Choose three.) A. disrupt B. volume C. snap-reserve D. try E. destroy Correct Answer: ADE :

10 ify.html QUESTION 15 You have a 4-node cluster serving home directories over two IPs per node. Which two methods would you use to set up DNS load balancing over a single name to the eight IP addresses? (Choose two.) A. On-Box DNS using a DNS delegation record B. Off-Box Round Robin DNS C. On-Node PTR records with reverse lookup per node D. Off-Node CNAME records for each node management interface Correct Answer: AB Reference: QUESTION 16 Which NetApp management tool generates reports on volume storage capacity trending information? A. Virtual Storage Console B. OnCommand Unified Manager C. OnCommand System Manager D. OnCommand Workflow Automation Correct Answer: B

11 QUESTION 17 When assigning shelf IDs to SAS-connected shelves, which statement is true? A. They only need to be unique within an HA pair. B. They only need to be unique within a stack. C. They only need to be unique within a node. D. They need to be unique within a cluster. Correct Answer: A : IDs must be unique within an HA pair. Reference: F2ED-4F3D-BC2A B4D.html QUESTION 18 When using SnapRestore, which two statements are true? (Choose two.) A. A single file can be restored. B. Performing a volume level restore from a Snapshot copy may delete other Snapshots. C. Individual LUNs cannot be restored. D. Before restoring a volume it must be taken offline. Correct Answer: AB QUESTION 19 A customer has a 1000 GB volume that is at 25% capacity and has no existing Snapshot

12 copies. The customer creates a Snapshot copy of the volume, creates a new 250 GB file, and deletes an existing 100 GB file. How much space is free in the volume? A. 350 GB B. 400 GB C. 500 GB D. 600 GB Correct Answer: C QUESTION 20 An administrator creates an account for a new user, and wants this user to have limited capabilities accessing SSH. The administrator defined the account, but the user still has full control. Which two settings would the administrator use to correct this problem? (Choose two.) A. the user account settings in OnCommand system Manager B. the user account settings of the admin account C. the user account settings in Windows Active Directory Users and Computers D. the user account settings in the clustershell Correct Answer: AD

13 QUESTION 21 Which port is used for untagged VLAN traffic? A. a0a-0 B. a0a C. e0a-999 D. 0a Correct Answer: B : The second character is a numeral identifying the slot in which the port adapter is located. QUESTION 22 A customer enables Flash Pool with SSD storage pools for an HA pair using a single SSD hot spare. The client has assigned aggregates from only cl-01 to Flash Pool storage pool. One of the SSDs in the storage pool fails and the customer observes that the SSd hot spare did not take the place of the failed drive. Why did this happen? A. The SSD hot spare is owned by cl-02. B. cl-01 contains an SSD aggregate. C. The minimum spare count option is set to 0. D. The SSD storage pool already contained the maximum number of disks. Correct Answer: A

14 Reference: QUESTION 23 In the storage failover command, what does the bypass-optimization option do? A. It takes over the partner node without performing aggregate relocation. B. It migrates all logical interfaces during takeover. C. It takes over without migrating all logical interfaces. D. It takes over the partner node performing aggregate relocation. Correct Answer: A : Take over the partner node without performing aggregate relocation storage failover takeover -bypass-optimization true Reference: QUESTION 24 An administrator enabled the iscsi protocol on an SVM and created a LUN for a Windows 2012 server. When the administrator uses Windows Disk Management, the LUN cannot be found. Which two statements describe how to solve this problem? (Choose two.) A. Create an igroup and add the iscsi IQN and then map it to the LUN. B. Configure the iscsi service on the Windows 2012 server. C. Disable the ALUA support for the igroup that is mapped to the LUN. D. Create an igroup and add the WWPN and then map it to the LUN.

15 Correct Answer: AB QUESTION 25 A user is reporting trouble using a SVM management LIF. You have verified host configuration, network connectivity, and that the LIF responds to pings. What should you do to continue troubleshooting this problem? A. Ensure the SVM management LIF's failover policy is correct. B. Ensure the SVM management LIF's administrative status is up. C. Ensure the SVM management LIF is on its home port. D. Ensure the SVM management LIF's firewall policy is set to management. Correct Answer: A : : You must have prepared the SVM networking for a major upgrade by creating the necessary SVM management LIFs, failover groups, and routes. Reference: 78F8-40B9-A62D-C5A6E62A53D7.html QUESTION 26 During a storage failover you run the storage failover show-takeover command and it displays the messages "relocating its SFO aggregate" and "CFO aggregates not attempted". How would you relocate the CFO aggregate? A. Wait for the failed controller to come online and takeover the aggregate.

16 B. Wait for the CFO aggregate to show "done" once the SFO is complete. C. Put the CFO aggregate online to force the data aggregate to come online. D. Force giveback of the failed controller to force that data aggregate to come online. Correct Answer: B QUESTION 27 A customer wants to improve write performance on their FAS2552 HA system. The system is built with SAS drives, and they are not interested in purchasing additional disk shelves. The workload consists of mostly small, random overwrites and random reads. What should the customer do to improve performance? A. Enable free space reallocation on the aggregate. B. Enable FlashCache on both nodes. C. Increase the amount of NVRAM in the system. D. Assign a Flash Pool RAID group to the aggregates. Correct Answer: D : A Flash Pool is built from a Data ONTAP aggregate in a two-step process, described in section 3,1, "7-Mode CLI." Essentially it is the addition of SSDs into an aggregate to provide a high-bandwidth, low-latency location that is capable of caching random reads and random overwrites. discussions/17208/1/43347_tr- 4070_NetApp_Flash_Pool_Design_and_Implementation_Guide.pdf QUESTION 28

17 Which data protocol is available to use on an SVM? A. FTP B. CIFS C. HTTP D. TFTP Correct Answer: B : You can configure CIFS and NFS protocols on the Storage Virtual Machine (SVM) to provide file-level data access for NAS clients. To enable CIFS protocol, you must create the data LIFs and the CIFS server. To enable NFS protocol, you can specify the NIS details in addition to the data LIFs. Reference: D-29F98AB6C2E7.html QUESTION 29 A customer wants different performance characteristics for applications that are using LUNs. They want to control the performance for FCP LUNs. Which two clustered Data ONTAP features foqos would you use to accomplish this task? (Choose two.) A. setting the policy group for the SVM that is hosting the LUNs for the customer's application B. setting the policy group for the volumes that are hosting the LUNs for the customer's applications C. setting the policy group for the FCP target ports that are being used for the LUNs D. setting the policy group for the igroups mapped to the LUNs that are hosting the customer's applications Correct Answer: AB

18 QUESTION 30 An administrator enabled the iscsi protocol on an SVM and created a LUN for a Windows 2012 server. When the administrator uses Windows Disk Management, the LUN cannot be found. What are two solutions for this problem? (Choose two.) A. Set up the Windows 2012 server to serve as an iscsi target for the LUN. B. Define the iscsi Send Targets in the igroup and map to the LUN. C. Define the iscsi IQN in the igroup and map to the LUN. D. Start the iscsi service on the Windows 2012 server. Correct Answer: CD QUESTION 31 Which statement is true about establishing a SnapMirror relationship in clustered data ONTAP? A. It sets up the relationship, but does not start the initial transfer B. It sets up the relationship on the source node only C. It sets up the relationship and starts the initial data transfer

19 D. It sets up the relationship and creates the destination volume Correct Answer: A : 3rd bullet QUESTION 32 Which LIF parameter determines the ports that the LIF moves to when the current interface goes offline? A. auto-revert B. ipspace C. failover-group D. netmask Correct Answer: C : You can revert a LIF to its home port after it fails over or is migrated to a different port either manually or automatically. If the home port of a particular LIF is unavailable, the LIF remains at its current port and is not reverted. 95F5-37DF76D8190E.html alse QUESTION 33 Which type of upgrade is supported from a single-node FAS2552 to a dual-node cluster

20 with clustered Data ONTAP 8.3 when all 10 GB ports are used for host access? A. a disruptive upgrade from a single-node cluster to a dual-node HA cluster B. a non-disruptive upgrade of a single-node cluster into a dual-node HA cluster C. a single-node cluster upgraded by migration of data to another single-node cluster D. a disruptive single-node cluster upgraded to a dual-node HA cluster by adding 10 Gb Ethernet cards Correct Answer: D QUESTION 34 A customer's Linux Oracle database requires a SAN solution with multiple FC connections for path resiliency and performance. The host has been provisioned with two dual-port FC HBAs, and each HBA is connected to each fabric. Before configuring the storage, what host information should the storage administrator obtain from the customer? (Choose two.) A. if the FC HBAs ports are all configured for an active/passive configuration. B. the amount of cache memory installed in the host C. if the DM-MP with ALUA support is configured on the host D. the WWPNs of all the FC ports in the host Correct Answer: CD QUESTION 35

21 A customer has an aggregate, aggr1_01 with three RAID groups: rg0, rg1, and rg2. Each RAID group has 15 disks, and the aggregate's maximum RAID group size is set to 18 disks. The customer adds three additional disks to the aggregate using the following command: storage aggregate add-disks aggregate aggr1_01 diskcount 3 How are the RAID groups affected by this command? A. The disks are added to a new RAID group rg3. B. Each RAID group receives one additional disk. C. The three disks are added to RAID group rg2. D. The three disks are added to RAID group rg0. Correct Answer: C QUESTION 36 What is the maximum size of a compression group? A. 8 KB B. 4 KB C. 32 KB D. 64 KB Correct Answer: C QUESTION 37

22 You have an aggregate with 10 TB free. You create a 1 TB volume with space-guarantee set to none. In that volume, you create a 500 GB LUN with space-reserve enabled. How much space is available in the aggregate before data is written to the LUN? A. 10 TB B. 9.5 TB C. 8.5 TB D. 9 TB Correct Answer: B QUESTION 38 A customer has configured SnapDrive for Windows to assist in creating Snapshot copies of a LUN. In SnapDrive, the transport protocol configuration uses the vsadminuser account for authentication. SnapDrive fails to connect to the SVM. Why did this failure occur? A. Transport protocol requires a domain Windows account. B. The vsadmin account is locked or does not have a password. C. SnapDrive requires a cluster-wide privileged account. D. Transport protocol requires a local Windows account. Correct Answer: B QUESTION 39

23 You create a 1000 GB volume with space-guarantee set to none and fractional-reserve set to 0. In that volume you create a 400 GB LUN with space-reserve enabled. How much space is available in the volume before data is written to the LUN? A. 400 GB B. 0 GB C. 600 GB D GB Correct Answer: C QUESTION 40 Which two must already exist before creating a subnet? (Choose two.) A. storage virtual machine B. failover group C. broadcast domain D. IPspace Correct Answer: CD Reference:

24 The IPspace feature enables a single storage system to be accessed by clients from more than one disconnected network, even if those clients are using the same IP address. An IPspace defines a distinct IP address space in which vfiler units can participate. IP addresses defined for an IPspace are applicable only within that IPspace. A distinct routing table is maintained for each IPspace. No cross-ipspace traffic routing happens. 91E8-EBF3E2047B06.html QUESTION 41 What is the minimum version of clustered Data ONTAP that supports shelf hot-remove? A B C D. 8.3 Correct Answer: A : If your system is running Data ONTAP or later, you can hot-remove disk shelves--physically remove disk shelves that have had the aggregates removed from the disk drives--in a clustered Data ONTAP multipath HA configuration with DS14 disk shelves that is up and serving data. Reference: QUESTION 42 A customer wants to use Storage Efficiency features on volumes used for backup/archive data. The customer is not concerned with performance degradation and is only concerned about storage efficiency. Which three Storage Efficiency features should be turned on to meet these needs?

25 (Choose three.) A. deduplication B. post compression C. storage QoS D. inline compression E. SyncMirror Correct Answer: ABD : Clustered-Data-ONTAP/ta-p/ QUESTION 43 Which type of connectivity is supported when connecting third-party arrays through FlexArray Virtualization for back-end storage to a NetApp cluster? A. iscsi B. SAS C. FC D. Infiniband Correct Answer: C Reference: On the back end, FlexArray attaches to your existing storage arrays via Fibre Channel and provides a virtualization layer between the storage array and the hosts QUESTION 44

26 Your company just purchased four additional FAS8060 nodes to add to an existing 12-node NAS cluster made up of FAS6290s. After joining the four new nodes, how many more nodes are allowed before you reach the maximum supported configuration for a mixed FAS6290/8060 cluster? A. 8 B. 2 C. 4 D. 16 Correct Answer: A Reference: QUESTION 45 You acquired a new company that has the same private IP address range. What must be set up on the NetApp cluster to support the duplicate networks? A. VLANs B. failover groups C. IPspaces D. DNS zone Correct Answer: C

27 QUESTION 46 At which two levels would you be able to create a SnapMirror policy? (Choose two.) A. aggregate B. cluster C. volume D. SVM Correct Answer: AC Reference: QUESTION 47 AutoSupport recently stopped working. No changes were made on the cluster itself. Which three factors outside of the cluster would cause the failure? (Choose three.) A. changes to DNS B. changes to the firewall C. changes to the Active Directory service account D. changes to your NetApp support user ID E. changes to the proxy server Correct Answer: ABE QUESTION 48

28 An administrator is attempting to add two FAS8020 nodes to an existing cluster of eight FAS2552 nodes. They are receiving an error when attempting to join the new nodes. What is causing this error? A. The cluster switch connections have been cabled incorrectly. B. The disk shelves on one of the new nodes are displaying an error. C. The maximum number of nodes is already in the cluster. D. The new nodes are running a newer version of clustered Data ONTAP. Correct Answer: C QUESTION 49 You just added a vsphere host to your environment that needs access to the existing NFS datasrtore. The applicable export policy is named VMW, and each host's IP address has been given access. What should you do to grant the new host access to the NFS datastore? A. Create a new volume. B. Create a new rule under the VMW export policy. C. Create a new SVM. D. Create a new export policy for the new host. Correct Answer: B : QUESTION 50

29 You create an SVM named svm7. Its DNS name is ntap7. In svm7, you create a volume named vol1 with a junction path of /users. An NFS client would mount the root of vol1 using which path? A. svm7:/users B. ntap7:/users C. ntap7:/vol1 D. svm7:/vol1 Correct Answer: B QUESTION 51 Which of the following is true about a data protection (DP) mirror destination volume? (Choose all that apply) A. Can be in the same vserver as the source B. Can be in a different vserver as the source C. Can be on a different cluster from the source D. Can be on a Data ONTAP 7-mode system E. Can be smaller than the source Correct Answer: ABC

30 QUESTION 52 Your application team needs to test a NAS volume using production data, but you do not have time to copy the data and do not have a disaster recovery site. In this scenario, which two statements are true when using FlexClone? (Choose two.) A. The clone will update automatically when the parent volume is updated. B. The clone can be made independent by splitting it from the parent volume. C. The clone can be moved to another aggregate keeping space efficiency. D. The clone can be cloned again for multi-phase testing. Correct Answer: BD QUESTION 53 You must monitor user login messages on your clustered Data ONTAP storage. Which tool provides a graphical user interface to view "unsuccessful login attempt" messages? A. OnCommand System Manager B. OnCommand Insight C. OnCommand Workflow Automation D. OnCommand log Manager Correct Answer: A

31 Reference: QUESTION 54 Your network and storage teams have decided to disable flow control on all host, switch, and NetApp interfaces, both 1 Gb and 10 Gb, to increase performance. Why does this action increase performance? A. It lets the NetApp MTU handle congestion control as needed. B. It lets the host-side MTU handle congestion control as needed. C. It lets the upper layer protocols handle congestion control as needed. D. It lets the lower layer protocols handle congestion control as needed. Correct Answer: C : Ports with standard MTU size and jumbo MTU size should never be mixed on the same VLAN. Consider a host and a NetApp F AS device configured on the same VLAN, where the FAS controller is configured for jumbo frames and the host is not. The host will be able to communicate to the FAS device using its standard 1500 byte frames. However, the reply back from the FAS device wi ll be a 9000 byte frame and because the two machines are located on the same VLAN, there is no device fragmenting this frame into the standard 1500 byte size for consumption by the host. ftp://ftp.netapp.com/pub/alim/pub/tr-3802.pdf QUESTION 55 A customer has LUNs that are being accessed through iscsi. The applications have experienced increased LUN latency over the last couple of days. Which two components should you review to determine what caused the rise in latency? (Choose two.)

32 A. node CPU utilization B. FC switch performance C. Ethernet network performance D. cluster management switch performance Correct Answer: AC QUESTION 56 An unexpected network outage has occurred and you have lost access to an NFS share inside an SVM on your cluster. What is causing the problem? A. The broadcast domain does not have a failover policy defined. B. The MTU setting for the port is incorrect. C. The failover group does not have the proper targets defined. D. The current port is already hosting a LIF. Correct Answer: C QUESTION 57 What are two FPolicy methods for applications? (Choose two.) A. asynchronous

33 B. semi-synchronous C. direct D. synchronous Correct Answer: AD Reference: QUESTION 58 What must be configured to support inter-cluster Snapmirror relationships? A. Cluster peer relationship B. Intercluster port role C. Junction path for the mirrored volume D. Minimum transfer size Correct Answer: A QUESTION 59 You have created a storage virtual machine named SVM1 with a NetBIOS name of FILES1 and you have successfully joined the Active Directory domain. You have created a CIFS share called SHARE1 and have given read/write access to all users. Network connectivity has been verified. To which path should the users be mapping? A. \\SHARE1\FILES1

34 B. \\FILES1\SHARE1 C. \\SVM1\FILES1 D. \\FILES1\SVM1 Correct Answer: B QUESTION 60 Which two backup engines are supported within clustered Data ONTAP? (Choose two.) A. SMT ape B. dump C. tape D. xcopy Correct Answer: AB Reference: QUESTION 61 What is true about a node root volume? A. There is a root volume on every node in a cluster.

35 B. It is the root of a data SVM's namespace. C. You can use vol move to move it to an aggregate on a different node. D. It is the most secure place to store critical user data. Correct Answer: B Reference: QUESTION 62 While reviewing a controller, you find that an aggregate aggr1 made of 6 TB hard-disk drives has two RAID groups, one with 14 disks and the other with eight disks. Which action caused the RAID groups to be different? A. The aggregate was created with the RAID group option set to 2. B. The aggregate was created with advanced drive partitioning. C. The aggregate was moved from one controller to its partner. D. The aggregate was created from the command line using the default configuration. Correct Answer: D QUESTION 63 In clustered Data ONTAP 8.2, which of the following commands will restore an entire volume A. volume snapshot promote

36 B. volume snapshot restore C. volume snapshot resync D. None of the above, just use the.snapshot or ~snapshot directory to restore the entire volume Correct Answer: B QUESTION 64 A customer has lost access to shares being used by an application. What are three troubleshooting steps the administrator should take? (Choose three.) A. Verify that the admin SVM is running on the node being accessed by the customer. B. Verify that the LIF resides on its home port. C. Verify that the LIFs in the SVM are all up and active. D. Verify that the SVM has CIFS running, that the share exists, and is online. E. Verify that there is network connectivity between the SMB client and the SVM. Correct Answer: CDE QUESTION 65 You set up a SnapMirror relationship between two clusters and start the SnapMirror initialization. The transfer starts without error and begins replicating data. Before the initialization completes, a network failure occurs and the transfer fails to finish. Once the network failure is corrected, you attempt to initialize the transfer again, but receive the following error:

37 Volume rep_vol01 is restricted Which step should you perform before attempting re-initialization? A. Change the state of the destination volume to online. B. Delete all Snapshot copies on the destination volume. C. Change the state of the destination volume to offline. D. Delete all data in the destination volume. Correct Answer: A QUESTION 66 A customer wants the best performance for their Oracle DB solution. They are willing to configure their high-availability nodes so the load is less than 50% per node, to protect performance during failover. They want to enhance read and write performance. Which NetApp technology accomplishes this task? A. deduplication B. thin provisioning C. Flash Pool D. FlashCache Correct Answer: C QUESTION 67

38 Node cl-02 needs to fail over for scheduled maintenance. The node has NAS LIFs on it. The failover needs to be non-disruptive to the NAS clients. Which command accomplishes this task? A. system node halt ofnode cl 02 inhibit true B. system node reboot ofnode cl 02 inhibittakeover true C. storage failover takeover ofnode cl 02 bypass optimization true D. storage failover takeover ofnode cl 02 Correct Answer: D QUESTION 68 Which three disk shelf types are supported in clustered Data ONTAP 8.3? (Choose three.) A. DS4486 B. DS14-MK4-FC C. DS14-MK2-FC D. DS14-MK2-AT E. DS14 Correct Answer: ABD : Disk shelves supported DS2246 (2U; 24 drives, 2.5" SFF) DS4246 (4U; 24 drives, 3.5" LFF) DS4486 (4U; 48 drives, 3.5" LFF) DS4243 (4U; 24 drives, 3.5" LFF) supported for upgrades only DS14 disk shelves (mk2-at, mk4) are supported for upgrades only

39 Reference: the table) QUESTION 69 Which hidden directory points to a Snapshot copy from an SMB client? A. /snapshot B..snapshot C. snapshot D. %snapshot Correct Answer: C : hidden ~snapshot directory is accessible Reference: The method that you use to access the ~snapshot directory from Windows clients using SMB BF08-D390CB6B3D89.html QUESTION 70 What is the speed of the cluster interconnect ports on a FAS2552? A. 10 Gb B. 1 Gb

40 C. 8 Gb D. 16 Gb Correct Answer: A QUESTION 71 Why would you use NetApp Snapshots? A. for data protection B. to increase performance C. for network resiliency D. for storage failover Correct Answer: A Reference: QUESTION 72 Your company is told that it must follow strict requirements for auditing purposes when creating user accounts for each department. Which feature in clustered Data ONTAP accomplishes this task? A. LDAP integration B. workgroup access C. role-based access control D. mixed-mode security

41 Correct Answer: C QUESTION 73 How many disks reside in a DS4246 shelf? A. 46 B. 42 C. 14 D. 24 Correct Answer: D : the Table). QUESTION 74 A customer wants to use jumbo frames on an interface group called a0a. Interface group a0a contains ports e0c and e0d. Additionally, the customer is using VLAN tagging for VLANs 510 and 520. VLAN 510 will use jumbo frames but VLAN 520 will not. When the customer tries to enable jumbo frames on a0a-510 the command fails. What caused the failure? A. The MTU size must be set on the broadcast domain to which the ports belong. B. The LIF corresponding with VLAN 510 is not configured for jumbo frames. C. Ports e0c and e0d have conflicting MTU sizes configured. D. Jumbo frames must be enabled from the advanced privilege set.

42 Correct Answer: A QUESTION 75 Which hidden directory points to a Snapshot copy from a NFS client? A. %snapshot B..snap C..snapshot D. /snapshot Correct Answer: C : This command rename the hidden.snapshot directory in every directory in the current volume. Reference: QUESTION 76 Which two default SVM roles are available when an SVM is created? (Choose two.) A. vsadmin-readonly B. root C. vsadmin D. admin Correct Answer: AC

43 Reference: 490B-4D6D-A18E C7.html(See the table 1st point and last point). QUESTION 77 What is the maximum number of nodes allowed in an FAS8000 series with a SAN configuration? A. 24 B. 8 C. 4 D. 2 Correct Answer: B : SAN: Up to 8 cluster nodes Reference: QUESTION 78 A customer wants to retire a broadcast domain called bcast1 from the cluster. All network ports and data LIFs previously using bcast1 have been moved to another broadcast domain. When the administrator attempts to delete the broadcast domain, the deletion fails. What is causing the problem? A. TheIPspace, that the broadcast domain uses, still exists. B. The cluster ports are using the bcast1 broadcast domain. C. There are still subnets associated with the broadcast domain. D. The SVM has not been deleted. Correct Answer: A

44 QUESTION 79 Which two solutions are valid for clustered Data ONTAP MetroCluster? (Choose two.) A. FAS3200 series controllers B. FAS2500 series controller C. four nodes at each site D. two nodes at each site Correct Answer: AD QUESTION 80 You notice your indirect I/O performance between nodes in your 4-node cluster is slowing down from prior week. Each node has two 10 GB connections to the cluster interconnect, one to each switch. You are using four out of 12 available ports on each cluster interconnect switch. Your cluster network utilization is over 80%. What should you do to increase cluster interconnect performance? A. Change the SFP+ from 10 Gb to 16 Gb on each node and switch. B. Add two more cluster interconnect connections per node. C. Add additional ISLs between the two cluster interconnect switches.

45 D. Change the cable from TwinAx to optical with SFP+ for better throughput. Correct Answer: B QUESTION 81 You change the volume junction-path of vol1 from /vol/vol1 to /vol1. NFS clients are unable to connect to the new path/vol1. Which mirrors need to be updated to solve this problem? A. TDP mirrors of the SVM root volume. B. XDP mirrors of the SVM root volume C. DP mirrors of the SVM root volume D. LS mirrors of the SVM root volume Correct Answer: D QUESTION 82 The cluster ha modify configured true command will trigger which two actions? (Choose two.) A. The ability for the nodes in an HA pair to execute an auto-giveback. B. The ability for the hosts connected to a node to failover to another HA pair. C. The storage can failover from one node to the other. D. SVM failover from any node in the cluster to any other node.

46 Correct Answer: BC QUESTION 83 What is a NetApp storage system Ethernet port name? A. e0/1 B. g0/1 C. e0a D. eth0 Correct Answer: C Reference: Discussions/e0M-Management-SP-Port/td-p/18499 QUESTION 84 You have two LIFs homed on the same single-mode interface group. You want to leverage both 10 Gb interfaces as active/active. What must you do to use both 10 Gb interfaces? A. Move one of the LIFs to another node in the cluster. B. Delete the interface group, and home each LIF to one port each. C. Create another single-mode interface group and move one LIF to it. D. Change the ifgrp distribution function from the default IP setting to MAC. Correct Answer: B

47 QUESTION 85 What are the two valid NDMP modes? (Choose two.) A. local-scoped B. node-scoped C. SVM-scoped D. cluster-scoped Correct Answer: BC If you install a new Data ONTAP 8.2 cluster, NDMP is in the SVM-scoped NDMP mode by default. To perform tape backup and restore operations in the node-scoped NDMP mode, you must explicitly enable the node-scoped NDMP mode Reference: A8B4-63D1C7F3D114.html QUESTION 86 You create a 150 GB thick-provisioned volume. In that volume, you create a 50 GB LUN with space-reserve enabled. You create another 50 GB LUN with space-reserve disabled. Before any data is written to either LUN or a Snapshot is taken, how much space will be available in the volume for additional LUNs? A. 150 GB

48 B. 100 GB C. 75 GB D. 50 GB Correct Answer: B QUESTION 87 When creating a data aggregate, what is the default minimum number of disks for RAID4 and RAID-DP? A. 5 for RAID4 and 9 for RAID-DP B. 4 for RAID4 and 7 for RAID-DP C. 3 for RAID4 and 5 for RAID-DP D. 2 for RAID4 and 3 for RAID-DP Correct Answer: C QUESTION 88 You have a cluster with a node running root data partitioning and need to grow the aggregate for additional data volumes. What is NetApp's best practice for increasing the aggregate size to optimize performance? A. Add 16 disks to the aggregate. B. Create a new aggregate and migrate all data with vol move. C. Add two disks to an existing RAID group.

49 D. Add a complete RAID group at a time. Correct Answer: D : best practices when you add storage to an aggregate optimizes aggregate performance: Add a complete RAID group at a time. Reference: 46AF EFF8A6A68B.html QUESTION 89 You have multiple volumes that are exported to a group of hosts within your environment. A new host needs access to the volumes. Which two actions accomplish this task? (Choose two.) A. Mount the new exports from the host. B. Create a new SVM. C. Create a rule in the export policy on the SVM. D. Create a new data LIF on the SVM. Correct Answer: AC QUESTION 90 What are the two valid settings for fractional reserve? (Choose two.)

50 A. 100% B. 20% C. 0% D. 50% Correct Answer: AC : The fractional reserve setting is expressed as a percentage; the only valid values are 0 and 100 percent. You use the vol options command to set fractional reserve. Reference: 8E9C C-633DFDD5A936.html QUESTION 91 Clustered Data ONTAP supports which three versions of NFS? (Choose three.) A. NFSv4.1 B. NFSv4 C. NFSv3 D. NFSv2 E. NFSv1 Correct Answer: BCD :

51 A315-5DD1FBB692F4.html QUESTION 92 Which two methods would be used to change root-data partitioning on an FAS2500? (Choose two.) A. OnCommand System Manager B. command line interface C. System Setup D. OnCommand Unified Manager Correct Answer: BC : DE0E-42CD AF879AF.html Topic 2, Volume B QUESTION 93 What type of configuration is required for SnapVault backup between clusters in two different clustered Data ONTAP or later systems? A. Vserver Peer Configuration B. SnapVault Peer Configuration C. Backup Peer Configuration D. Cluster Peer Configuration Correct Answer: D

52 QUESTION 94 With clustered Data ONTAP 8.2 or later, an administrator may use NDMP commands at which two levels? (Choose Two) A. Node B. Cluster C. Intercluster D. Vserver Correct Answer: AD QUESTION 95 What CLI command restores entire volume from a snapshot copy: A. Volume snapshot restore B. Volume snapshot promote C. Volume snapmirror restore D. Volume snapmirror resync Correct Answer: A : The command is "volume snapshot restore", The command "volume snapshot promote" does not exist in Ontap 8.2 c1::*> vol snapshot? (volume snapshot)

53 autodelete> Manage snapshot autodelete settings compute-reclaimable *Calculate the reclaimable space if specified snapshots are deleted create Create a snapshot delete Delete a snapshot modify Modify snapshot attributes partial-restore-file Restore part of a file from a snapshot policy> Manage snapshot policies rename Rename a snapshot restore *Restore the volume to a snapshot. restore-file Restore a file from a snapshot show Display a list of Snapshot copies QUESTION 96 Which four features does Cluster-Mode support? (Choose four.) A. Data protection mirrors B. Load-sharing mirrors C. NDMP tape backup D. Non-disruptive upgrades E. Synchronous SnapMirror Correct Answer: ABCD QUESTION 97 Which of these correctly describes single-node clusters? A. They support storage failover B. They support nondistruptive upgrade C. They have no cluster LIFs D. They are identical to one-node clusters

54 Correct Answer: C QUESTION 98 What are two ways a storage administrator can improve the operational availability of NAS application data? (Choose two.) A. By backing up data to a USB disk B. By configuring ALUA on the host C. By providing multiple data logical interfaces D. By utilizing the volume move feature Correct Answer: CD QUESTION 99 What are the characteristics of Snapmirror? (choose three) A. Provides data protection for disaster recovery B. If the source FlexVol volume is lost, clients can restore data from the secondary to primary storage C. Can asynchronously copy the source FlexVol volume to a disaster recovery replica D. If the source FlexVol volume is lost or destroyed, clients can connect to the mirror image of the source data Correct Answer: ACD

55 QUESTION 100 Which statement is true when a two node switchless cluster is grown to a four-node cluster? A. The new HA-pair connected to two new cluster switches and the existing two-node cluster will connect one path at a time to the new cluster switches. B. There is a short outage while the new HA pair and existing two node cluster add additional NVRAM cards for cluster connections. C. The new HA pair is direct-attached to the existing two-node cluster-free 10 GbE ports without adding switches. D. The new HA pair is connected to four new cluster switches and the existing two-node cluster will connect one path at a time to the new cluster switches. Correct Answer: A QUESTION 101 Which of the following are appropriate client specification for an export rule? (Choose all that apply) A /0 B /24 C..eng.netapp.com

56 D. \\vs_root\ Correct Answer: ABC QUESTION 102 Which of these correctly describes single-node clusters? A. They support storage failover B. They support nondistruptive upgrade C. They have no cluster LIFs D. They are identical to one-node clusters Correct Answer: C QUESTION 103 In transitioning SnapVault relationships from 7-mode to clustered Data ONTAP, which statements are true? (Choose three) A. You are required to re-create all Snapvault relationships with new baseline B. You can plan on fan-in relationships of many source volume to one destination volume C. You can plan on fan-in relationships at the system level, many volumes to one Vserver D. You can plan on SnapMirror to SnapVault cascades Correct Answer: ACD

57 QUESTION 104 For NDMP to be aware of a vserver, what actions needs to be taken? (choose three) A. Data management application B. Cluster-aware backup C. NDMP scope listed D. NDMP service enabled Correct Answer: ABD QUESTION 105 NFSv4.1 pnfs reduces traffic over which network? A. cluster network B. data network C. InfiniBand network D. management network Correct Answer: A : Link: pdf&pdfUri=tcm:

58 QUESTION 106 Within clustered Data ONTAP 8.2 or later, which two types of FPolicy integrations are supported? (Choose two) A. Text-based FPolicy B. SAN-based FPolicy C. Native Blocking D. External FPolicy serve Correct Answer: CD : Link: QUESTION 107 What is the first step for setting up a cluster Data ONTAP 8.2? A. Cluster Setup B. Join Cluster C. Install second node D. Enable HA Correct Answer: A : Setting up the cluster involves creating the cluster on the first node, joining any remaining nodes to the cluster, and configuring a number of features--such as synchronizing the system time--that enable the cluster to operate nondisruptively. The cluster setup command runs the cluster setup wizard, which can be used to either

59 create a cluster or join a node to an existing cluster. When you run the cluster setup wizard, enter the appropriate information at the prompts. You will be asked to provide the following information to create a cluster: Cluster name Cluster base license key Feature license keys Cluster administrator's password Cluster management interface port, IP address, netmask, default gateway Node management interface port, IP address, netmask, default gateway DNS domain names Name server IP addresses Location You will be asked to provide the following information to join a cluster: Cluster name Node management interface port, IP address, netmask, default gateway Link: QUESTION 108 Which two devices support the NetApp Remote Support Agent (RSA)? A. SP B. RTC C. RLM D. ILO E. BMC Correct Answer: AC : (page 9) QUESTION 109 A data Vserver can contain which three elements? (Choose three.)

60 A. Aggregates B. Data LIF C. NAS volumes D. Other Vservers E. Ports F. SAN LUNs G. A Vfiler Correct Answer: BEF QUESTION 110 What are four storage efficiency features Data ONTAP 8.1 Cluster-Mode provides? (Choose four.) A. transparent files B. thin provisioning C. SnapVault D. FlexClone E. deduplication F. compression Correct Answer: BDEF QUESTION 111 Which statement is true about a SnapMirror destination vserver?

61 A. It must have a read-only Vserver root volume. B. It must be in the same cluster as the source Vserver C. It must be created with the same language type as the source Vserver. D. It must have a different storage efficiency policy than the source Vserver. Correct Answer: C : Training material: Clustered_Data_ONTAP_82_Data_Protection_Guide How volume SnapMirror works with deduplication You can use volume SnapMirror to replicate a deduplicated volume regardless of size of the volume and logical data in the volume. When using volume SnapMirror with deduplication, you must consider the following information: You can enable deduplication on the source system, the destination system, or both systems. The shared blocks are transferred only once. Therefore, deduplication also reduces the use of network bandwidth. When the volume SnapMirror relationship is broken, the default deduplication schedule is applied at the destination storage system. When configuring volume SnapMirror and deduplication, you should coordinate the deduplication scheduleand the volume SnapMirror schedule. You should start volume SnapMirror transfers of a deduplicated volume after the deduplication operation is complete. This schedule prevents the sending of undeduplicated data and additional temporary metadata files over the network. If the temporary metadata files in the source volume are locked in Snapshot copies, these files consume extra space in the source and destination volumes. QUESTION 112 What happens if a load Sharing (LS) mirror replies a Vserver root volume to any node in the cluster and you promote one of the mirror destinations? A. All clients temporarily gain read/write access to the root volume B. The original source volume is prevented from becoming stale. C. All clients must re mount.

ns0-157 Passing Score: 700 Time Limit: 120 min File Version: 1.0

ns0-157 Passing Score: 700 Time Limit: 120 min File Version: 1.0 ns0-157 Passing Score: 700 Time Limit: 120 min File Version: 1.0 http://www.gratisexam.com/ Exam A QUESTION 1 An IPspace is associated with exactly one? A. broadcast domain B. SVM C. port D. root volume

More information

Netapp Exam NS0-157 NetApp Certified Data Administrator, Clustered Data ONTAP Version: 11.0 [ Total Questions: 302 ]

Netapp Exam NS0-157 NetApp Certified Data Administrator, Clustered Data ONTAP Version: 11.0 [ Total Questions: 302 ] s@lm@n Netapp Exam NS0-157 NetApp Certified Data Administrator, Clustered Data ONTAP Version: 11.0 [ Total Questions: 302 ] https://certkill.com Topic break down Topic No. of Questions Topic 1: Volume

More information

Exam Questions NS0-157

Exam Questions NS0-157 Exam Questions NS0-157 NetApp Certified Data Administrator, Clustered https://www.2passeasy.com/dumps/ns0-157/ 1. Clustered Data ONTAP supports which three versions of NFS? (Choose three.) A. NFSv4.1 B.

More information

Outline: ONTAP 9 Cluster Administration and Data Protection Bundle (CDOTDP9)

Outline: ONTAP 9 Cluster Administration and Data Protection Bundle (CDOTDP9) Outline: ONTAP 9 Cluster Administration and Data Protection Bundle (CDOTDP9) Cluster Module 1: ONTAP Overview Data Fabric ONTAP software Fabric layers The cluster Nodes High-availability pairs Networks

More information

NetApp. Number: NS0-156 Passing Score: 800 Time Limit: 120 min File Version: 1.0.

NetApp. Number: NS0-156 Passing Score: 800 Time Limit: 120 min File Version: 1.0. NetApp Number: NS0-156 Passing Score: 800 Time Limit: 120 min File Version: 1.0 http://www.gratisexam.com/ Exam A QUESTION 1 Which statement is true about a Data Protection (DP)-type SnapMirror destination

More information

Cluster Management Workflows for OnCommand System Manager

Cluster Management Workflows for OnCommand System Manager ONTAP 9 Cluster Management Workflows for OnCommand System Manager August 2018 215-12669_C0 doccomments@netapp.com Table of Contents 3 Contents OnCommand System Manager workflows... 5 Setting up a cluster

More information

Testkings NS q

Testkings NS q Testkings NS0-156 307q Number: NS0-156 Passing Score: 800 Time Limit: 120 min File Version: 12.5 Network Appliance NS0-156 Data ONTAP Cluster-Mode Administrator Passed on 2-02-15 with an 890. Dump still

More information

ONTAP 9 Cluster Administration. Course outline. Authorised Vendor e-learning. Guaranteed To Run. DR Digital Learning. Module 1: ONTAP Overview

ONTAP 9 Cluster Administration. Course outline. Authorised Vendor e-learning. Guaranteed To Run. DR Digital Learning. Module 1: ONTAP Overview ONTAP 9 Cluster Administration Course Code: Duration: 3 Days Product Page: https://digitalrevolver.com/product/ontap-9-cluster-administration-2/ This 3-day, instructor led course uses lecture and hands-on

More information

NetApp NS0-156_formatted

NetApp NS0-156_formatted NetApp NS0-156_formatted Number: 000-000 Passing Score: 800 Time Limit: 120 min File Version: 1.0 http://www.gratisexam.com/ NetApp NS0-156 Data ONTAP Cluster-Mode Administrator Version: 6.1 Exam A QUESTION

More information

NS Number: NS0-507 Passing Score: 800 Time Limit: 120 min File Version: NS0-507

NS Number: NS0-507 Passing Score: 800 Time Limit: 120 min File Version: NS0-507 NS0-507 Number: NS0-507 Passing Score: 800 Time Limit: 120 min File Version: 1.0 NS0-507 NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP Exam A QUESTION 1 You are asked to create a

More information

NS0-511 netapp. Number: NS0-511 Passing Score: 800 Time Limit: 120 min.

NS0-511 netapp. Number: NS0-511 Passing Score: 800 Time Limit: 120 min. NS0-511 netapp Number: NS0-511 Passing Score: 800 Time Limit: 120 min Exam A QUESTION 1 A customer wants to maintain a single copy for both disaster recovery and backup on a secondary system. Which SnapMirror

More information

SnapMirror Configuration and Best Practices Guide for Clustered Data ONTAP

SnapMirror Configuration and Best Practices Guide for Clustered Data ONTAP Technical Report SnapMirror Configuration and Best Practices Guide for Clustered Data ONTAP Amit Prakash Sawant, NetApp December 2013 TR-4015 SnapMirror Configuration and Best Practices This document describes

More information

NS0-191 netapp. Number: NS0-191 Passing Score: 800 Time Limit: 120 min.

NS0-191 netapp. Number: NS0-191 Passing Score: 800 Time Limit: 120 min. NS0-191 netapp Number: NS0-191 Passing Score: 800 Time Limit: 120 min Exam A QUESTION 1 An administrator notices that the clustered Data ONTAP 8.2.3 controllers are less responsive than normal. You use

More information

Clustered Data ONTAP Administration and Data Protection

Clustered Data ONTAP Administration and Data Protection Clustered Data ONTAP Administration and Data Protection COURSE OVERVIEW: This course uses lecture and hands-on exercises to teach basic administration of clustered Data ONTAP. In this course, you will

More information

NETAPP - Accelerated NCDA Boot Camp Data ONTAP 7-Mode

NETAPP - Accelerated NCDA Boot Camp Data ONTAP 7-Mode NETAPP - Accelerated NCDA Boot Camp Data ONTAP 7-Mode Duration: 5 Days Course Price: $5,850 Course Description Course Overview This training course is a 5-day boot camp with extended hours. The training

More information

NetApp NS0-511 Exam. Volume: 65 Questions

NetApp NS0-511 Exam. Volume: 65 Questions Volume: 65 Questions Question No: 1 You are creating a SnapMirror relationship and custom SnapMirror policies are not defined. Which default policy will be applied in this scenario? A. MirrorAndVault B.

More information

PASS4TEST. IT Certification Guaranteed, The Easy Way! We offer free update service for one year

PASS4TEST. IT Certification Guaranteed, The Easy Way!   We offer free update service for one year PASS4TEST \ http://www.pass4test.com We offer free update service for one year Exam : NS0-157 Title : NetApp Certified Data Administrator, Clustered Data ONTAP Vendor : Network Appliance Version : DEMO

More information

NS0-180 netapp

NS0-180 netapp NS0-180 netapp Number: NS0-180 Passing Score: 800 Time Limit: 120 min Exam A QUESTION 1 You want to create a data volume on aggr0 and you receive a message with the following warning: ''Warning: You are

More information

Cluster Management Workflows for OnCommand System Manager

Cluster Management Workflows for OnCommand System Manager ONTAP 9 Cluster Management Workflows for OnCommand System Manager June 2017 215-11440-C0 doccomments@netapp.com Updated for ONTAP 9.2 Table of Contents 3 Contents OnCommand System Manager workflows...

More information

Clustered Data ONTAP 8.3 Administration and Data Protection Workshop

Clustered Data ONTAP 8.3 Administration and Data Protection Workshop NA-CDOTDP-WS Clustered Data ONTAP 8.3 Administration and Data Protection Workshop Prerequisites A basic understanding of system administration with UNIX or Windows is recommended as well as the web-based

More information

NS0-158 netapp. Number: NS0-158 Passing Score: 800 Time Limit: 120 min.

NS0-158 netapp. Number: NS0-158 Passing Score: 800 Time Limit: 120 min. NS0-158 netapp Number: NS0-158 Passing Score: 800 Time Limit: 120 min Exam A QUESTION 1 What are three causes of a storage failover partial giveback? (Choose three.) A. iscsi sessions are active. B. AutoSupports

More information

Cluster Management Workflows for OnCommand System Manager

Cluster Management Workflows for OnCommand System Manager Clustered Data ONTAP 8.3 Cluster Management Workflows for OnCommand System Manager February 2016 215-10887_A0 doccomments@netapp.com Updated for 8.3.2 Table of Contents 3 Contents Contents of the Workflow

More information

Accelerated NCDA Boot Camp Data ONTAP 7-Mode (ANCDABC87)

Accelerated NCDA Boot Camp Data ONTAP 7-Mode (ANCDABC87) Accelerated NCDA Boot Camp Data ONTAP 7-Mode (ANCDABC87) COURSE OVERVIEW: This is a 5-day bootcamp that expands upon what students learned in the D7ADM course in order to prepare for the NCDA 7-mode certification

More information

Clustered Data ONTAP Administration (DCADM)

Clustered Data ONTAP Administration (DCADM) Clustered Data ONTAP Administration (DCADM) COURSE OVERVIEW: This course uses lecture and hands-on exercises to teach basic administration of clustered Data ONTAP. In this course you configure and manage

More information

Infinite Volumes Management Guide

Infinite Volumes Management Guide ONTAP 9 Infinite Volumes Management Guide September 2016 215-11160_B0 doccomments@netapp.com Visit the new ONTAP 9 Documentation Center: docs.netapp.com/ontap-9/index.jsp Table of Contents 3 Contents

More information

OnCommand Unified Manager 6.1

OnCommand Unified Manager 6.1 OnCommand Unified Manager 6.1 Administration Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277 Web:

More information

Accelerated NCDA Boot Camp Data ONTAP 7-Mode Course ANCDABC87; 5 Days, Instructor-led

Accelerated NCDA Boot Camp Data ONTAP 7-Mode Course ANCDABC87; 5 Days, Instructor-led Accelerated NCDA Boot Camp Data ONTAP 7-Mode Course ANCDABC87; 5 Days, Instructor-led Course Description Prepare for success when taking the NS0-155 NetApp Certified Data Management 7-Mode Administrator

More information

NS0-171.network appliance

NS0-171.network appliance NS0-171.network appliance Number: NS0-171 Passing Score: 800 Time Limit: 120 min Exam A QUESTION 1 An administrator is deploying a FlexPod solution for use with VMware vsphere 6.0. The storage environment

More information

Exam Questions NS0-156

Exam Questions NS0-156 Exam Questions NS0-156 Data ONTAP Cluster-Mode Administrator http://www.2passeasy.com/dumps/ns0-156/ 1. What are the three types of Vservers in clustered Data ONTAP 8.2? (Choose all that apply) A. System

More information

Exam Questions NS0-180

Exam Questions NS0-180 Exam Questions NS0-180 NetApp Certified Storage Installation Engineer, Clustered Data ONTAP https://www.2passeasy.com/dumps/ns0-180/ 1. Which three types of interface groups are supported on NetApp storage

More information

Clustered Data ONTAP 8.2

Clustered Data ONTAP 8.2 Clustered Data ONTAP 8.2 SAN Express Setup Guide for 62xx Systems NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1(408) 822-6000 Fax: +1(408) 822-4501 Support telephone: +1 (888)

More information

Data Fabric Solution for Cloud Backup Workflow Guide

Data Fabric Solution for Cloud Backup Workflow Guide Data Fabric Solutions Data Fabric Solution for Cloud Backup Workflow Guide Using ONTAP, SnapCenter, and AltaVault June 2017 215-11811_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether

More information

Netapp.Examsheets.NS0-156.v by.Luger.154q. Exam Code: NS Exam Name: Data ONTAP Cluster-Mode Administrator

Netapp.Examsheets.NS0-156.v by.Luger.154q. Exam Code: NS Exam Name: Data ONTAP Cluster-Mode Administrator Netapp.Examsheets.NS0-156.v2014-01-15.by.Luger.154q Number: NS0-156 Passing Score: 800 Time Limit: 120 min File Version: 20.5 http://www.gratisexam.com/ Exam Code: NS0-156 Exam Name: Data ONTAP Cluster-Mode

More information

NS0-506 Q&As NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP

NS0-506 Q&As NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP CertBus.com NS0-506 Q&As NetApp Certified Implementation Engineer - SAN, Clustered Data ONTAP Pass NetApp NS0-506 Exam with 100% Guarantee Free Download Real Questions & Answers PDF and VCE file from:

More information

OnCommand Unified Manager 6.1 Administration Guide

OnCommand Unified Manager 6.1 Administration Guide IBM System Storage N series OnCommand Unified Manager 6.1 Administration Guide SC27-6627-00 Table of Contents 3 Contents Preface... 7 Supported features... 7 Websites... 7 Getting information, help, and

More information

Monitoring and Reporting for an ONTAP Account

Monitoring and Reporting for an ONTAP Account This chapter contains the following sections: About, page 1 About Disks, page 2 Managing Filers, page 3 Managing Virtual Machines, page 3 Managing Interfaces, page 6 Managing IP Spaces, page 7 Managing

More information

Data ONTAP 7-Mode Administration Course D7ADM; 5 Days, Instructor-led

Data ONTAP 7-Mode Administration Course D7ADM; 5 Days, Instructor-led Data ONTAP 7-Mode Administration Course D7ADM; 5 Days, Instructor-led Course Description Welcome to the NetApp Data ONTAP 7-Mode Administration course. Data ONTAP 8 is the next generation data storage

More information

Copy-Based Transition Guide

Copy-Based Transition Guide 7-Mode Transition Tool 3.2 Copy-Based Transition Guide For Transitioning to ONTAP February 2017 215-11978-A0 doccomments@netapp.com Table of Contents 3 Contents Transition overview... 6 Copy-based transition

More information

NetworkAppliance NS NetApp Certified Data Administrator, ONTAP.

NetworkAppliance NS NetApp Certified Data Administrator, ONTAP. NetworkAppliance NS0-158 NetApp Certified Data Administrator, ONTAP http://killexams.com/pass4sure/exam-detail/ns0-158 Question: 67 What is the minimum number of disks required to create a data aggregate

More information

This course is intended for those who provide basic support for and perform administrative functions of the Data ONTAP operating system.

This course is intended for those who provide basic support for and perform administrative functions of the Data ONTAP operating system. Accelerated NCDA Boot Camp Data ONTAP 8.0 7-Mode (ANCDABC87) Who should attend This course is intended for those who provide basic support for and perform administrative functions of the Data ONTAP operating

More information

7-Mode Data Transition Using SnapMirror

7-Mode Data Transition Using SnapMirror Clustered Data ONTAP 8.3 7-Mode Data Transition Using SnapMirror February 2016 215-10873_A0 doccomments@netapp.com Updated for 8.3.2 Table of Contents 3 Contents Transitioning 7-Mode volumes using SnapMirror...

More information

Clustered Data ONTAP 8.2 High-Availability Configuration Guide

Clustered Data ONTAP 8.2 High-Availability Configuration Guide IBM System Storage N series Clustered Data ONTAP 8.2 High-Availability Configuration Guide SC27-6276-02 Table of Contents 3 Contents Preface... 7 About this guide... 7 Supported features... 7 Websites...

More information

7-Mode Transition Tool 2.2

7-Mode Transition Tool 2.2 7-Mode Transition Tool 2.2 Copy-Based Transition Guide For Transitioning to Clustered Data ONTAP NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501

More information

Data ONTAP 8.2. MultiStore Management Guide For 7-Mode. Updated for NetApp, Inc. 495 East Java Drive Sunnyvale, CA U.S.

Data ONTAP 8.2. MultiStore Management Guide For 7-Mode. Updated for NetApp, Inc. 495 East Java Drive Sunnyvale, CA U.S. Updated for 8.2.2 Data ONTAP 8.2 MultiStore Management Guide For 7-Mode NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone:

More information

Copy-Free Transition Guide

Copy-Free Transition Guide 7-Mode Transition Tool 3.0 Copy-Free Transition Guide For Transitioning to ONTAP September 2016 215-11373_B0 doccomments@netapp.com Table of Contents 3 Contents Transition overview... 6 Copy-free transition

More information

Netapp.Actualtests.NS0-156.v by.LIZZIE.154q

Netapp.Actualtests.NS0-156.v by.LIZZIE.154q Netapp.Actualtests.NS0-156.v2014-05-26.by.LIZZIE.154q Number: NS0-156 Passing Score: 800 Time Limit: 120 min File Version: 20.5 http://www.gratisexam.com/ Exam Code: NS0-156 Exam Name: Data ONTAP Cluster-Mode

More information

Clustered Data ONTAP 8.2

Clustered Data ONTAP 8.2 Clustered Data ONTAP 8.2 NAS Express Setup Guide for 62xx Systems NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888)

More information

PASS4TEST. IT Certification Guaranteed, The Easy Way! We offer free update service for one year

PASS4TEST. IT Certification Guaranteed, The Easy Way!   We offer free update service for one year PASS4TEST \ http://www.pass4test.com We offer free update service for one year Exam : NS0-511 Title : NetApp Certified Implementation Engineer - Data Protection Vendor : Network Appliance Version : DEMO

More information

Actual4Test. Actual4test - actual test exam dumps-pass for IT exams

Actual4Test.  Actual4test - actual test exam dumps-pass for IT exams Actual4Test http://www.actual4test.com Actual4test - actual test exam dumps-pass for IT exams Exam : NS0-158 Title : NetApp Certified Data Administrator, ONTAP Vendor : Network Appliance Version : DEMO

More information

7-Mode Data Transition Using SnapMirror Technology

7-Mode Data Transition Using SnapMirror Technology ONTAP 9 7-Mode Data Transition Using SnapMirror Technology September 2016 215-11153_B0 doccomments@netapp.com Visit the new ONTAP 9 Documentation Center: docs.netapp.com/ontap-9/index.jsp Table of Contents

More information

SAN Administration Guide

SAN Administration Guide ONTAP 9 SAN Administration Guide November 2017 215-11147_E0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 7 Understanding SAN host provisioning...

More information

ONTAP 9.3 Cluster Administration and Data Protection Bundle (CDOTDP9)

ONTAP 9.3 Cluster Administration and Data Protection Bundle (CDOTDP9) ONTAP 9.3 Cluster Administration and Data Protection Bundle (CDOTDP9) COURSE OVERVIEW: This 5-day course comprises the 3-day ONTAP 9.3 Cluster Administration (ONTAP9ADM) followed by the 2-day ONTAP 9.3

More information

Network- Appliance EXAM - NS NetApp Certified Implementation Engineer - SAN, Cluster-Mode. Buy Full Product

Network- Appliance EXAM - NS NetApp Certified Implementation Engineer - SAN, Cluster-Mode. Buy Full Product Network- Appliance EXAM - NS0-504 NetApp Certified Implementation Engineer - SAN, Cluster-Mode Buy Full Product http://www.examskey.com/ns0-504.html Examskey Network-Appliance NS0-504 exam demo product

More information

64-Bit Aggregates. Overview and Best Practices. Abstract. Data Classification. Technical Report. GV Govindasamy, NetApp April 2015 TR-3978

64-Bit Aggregates. Overview and Best Practices. Abstract. Data Classification. Technical Report. GV Govindasamy, NetApp April 2015 TR-3978 Technical Report 64-Bit Aggregates Overview and Best Practices GV Govindasamy, NetApp April 2015 TR-3978 Abstract Earlier releases of NetApp Data ONTAP used data block pointers in 32-bit format which limited

More information

PASS4TEST. IT Certification Guaranteed, The Easy Way! We offer free update service for one year

PASS4TEST. IT Certification Guaranteed, The Easy Way!  We offer free update service for one year PASS4TEST \ http://www.pass4test.com We offer free update service for one year Exam : NS0-504 Title : NetApp Certified Implementation Engineer - SAN, Cluster-Mode Vendor : Network Appliance Version : DEMO

More information

Volume Disaster Recovery Express Guide

Volume Disaster Recovery Express Guide ONTAP 9 Volume Disaster Recovery Express Guide December 2017 215-11188_E0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 4 Volume disaster

More information

Netapp Exam NS0-155 Data ONTAP 7-Mode Administrator Version: 6.2 [ Total Questions: 173 ]

Netapp Exam NS0-155 Data ONTAP 7-Mode Administrator Version: 6.2 [ Total Questions: 173 ] s@lm@n Netapp Exam NS0-155 Data ONTAP 7-Mode Administrator Version: 6.2 [ Total Questions: 173 ] Question No : 1 Which command is used to set the configuration of an Ethernet network interface? A. ifconfig

More information

Data ONTAP Mode Release Notes

Data ONTAP Mode Release Notes IBM System Storage N series Data ONTAP 8.0.4 7-Mode Release Notes GA32-0723-15 Contents Data ONTAP 8.0.4 7-Mode Release Notes.................... 1 Changes introduced since Data ONTAP 8.0....................

More information

SAN Configuration Guide

SAN Configuration Guide ONTAP 9 SAN Configuration Guide November 2017 215-11168_G0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Considerations for iscsi configurations... 5 Ways to configure iscsi

More information

High Availability and MetroCluster Configuration Guide For 7-Mode

High Availability and MetroCluster Configuration Guide For 7-Mode Updated for 8.2.1 Data ONTAP 8.2 High Availability and MetroCluster Configuration Guide For 7-Mode NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501

More information

OnCommand Cloud Manager 3.2 Deploying and Managing ONTAP Cloud Systems

OnCommand Cloud Manager 3.2 Deploying and Managing ONTAP Cloud Systems OnCommand Cloud Manager 3.2 Deploying and Managing ONTAP Cloud Systems April 2017 215-12035_C0 doccomments@netapp.com Table of Contents 3 Contents Before you create ONTAP Cloud systems... 5 Logging in

More information

Clustered Data ONTAP 8.2

Clustered Data ONTAP 8.2 Updated for 8.2.1 Clustered Data ONTAP 8.2 SAN Administration Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888)

More information

Network Management Guide

Network Management Guide ONTAP 9 Network Management Guide November 2017 215-11141_E0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 7 Networking components of a

More information

NetApp FAS8000 Series

NetApp FAS8000 Series Datasheet NetApp FAS8000 Series Respond more quickly to changing IT needs with unified scale-out storage and industry-leading data management KEY BENEFITS Support More Workloads Run SAN and NAS workloads

More information

Data Protection Guide

Data Protection Guide SnapCenter Software 4.0 Data Protection Guide For VMs and Datastores using the SnapCenter Plug-in for VMware vsphere March 2018 215-12931_C0 doccomments@netapp.com Table of Contents 3 Contents Deciding

More information

NS0-145 netapp

NS0-145 netapp NS0-145 netapp Number: NS0-145 Passing Score: 800 Time Limit: 120 min Exam A QUESTION 1 To automatically export volumes and directories on reboot, include them in the /etc/exports file. A. True B. False

More information

Cluster Management Using OnCommand System Manager

Cluster Management Using OnCommand System Manager ONTAP 9 Cluster Management Using OnCommand System Manager November 2017 215-12668_A0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Understanding System Manager... 15 Icons

More information

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Workflow Guide for 7.2 release July 2018 215-13170_B0 doccomments@netapp.com Table of Contents 3 Contents Deciding

More information

SnapDrive 5.3 for UNIX

SnapDrive 5.3 for UNIX SnapDrive 5.3 for UNIX Administration Guide for Linux NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone: +1 (888) 463-8277

More information

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere

Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Virtual Storage Console, VASA Provider, and Storage Replication Adapter for VMware vsphere Administration Guide for 7.2 release June 2018 215-13169_A0 doccomments@netapp.com Table of Contents 3 Contents

More information

Data ONTAP 8.1 High Availability and MetroCluster Configuration Guide For 7-Mode

Data ONTAP 8.1 High Availability and MetroCluster Configuration Guide For 7-Mode IBM System Storage N series Data ONTAP 8.1 High Availability and MetroCluster Configuration Guide For 7-Mode This Release Candidate publication is provided in conjunction with a Data ONTAP 8.1.2 RC code

More information

Installation and Cluster Deployment Guide for VMware

Installation and Cluster Deployment Guide for VMware ONTAP Select 9 Installation and Cluster Deployment Guide for VMware Using ONTAP Select Deploy 2.8 June 2018 215-13347_B0 doccomments@netapp.com Updated for ONTAP Select 9.4 Table of Contents 3 Contents

More information

NetApp DataMotion for vfiler with NetApp Data ONTAP 7.3

NetApp DataMotion for vfiler with NetApp Data ONTAP 7.3 Technical Report NetApp DataMotion for vfiler with NetApp Data ONTAP 7.3 Larry Touchette, Roger Weeks, and Raghunatha Reddy, NetApp June 2012 TR-3814 Executive Summary This document is an overview of NetApp

More information

SnapDrive for UNIX

SnapDrive for UNIX SnapDrive 5.2.1 for UNIX Installation and Administration Guide For Linux NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone:

More information

Clustered Data ONTAP Release Notes

Clustered Data ONTAP Release Notes IBM System Storage N series Clustered Data ONTAP 8.2.3 Release Notes SC27-6290-05 Contents Clustered Data ONTAP 8.2.3 Release Notes.................... 1 Changes introduced since Data ONTAP 8.2....................

More information

FlexArray Virtualization

FlexArray Virtualization Updated for 8.3.2 FlexArray Virtualization Installation Requirements and Reference Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support

More information

Clustered Data ONTAP 8.3

Clustered Data ONTAP 8.3 Updated for 8.3.1 Clustered Data ONTAP 8.3 Using All Flash FAS with Clustered Data ONTAP NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support

More information

Benefits of Multi-Node Scale-out Clusters running NetApp Clustered Data ONTAP. Silverton Consulting, Inc. StorInt Briefing

Benefits of Multi-Node Scale-out Clusters running NetApp Clustered Data ONTAP. Silverton Consulting, Inc. StorInt Briefing Benefits of Multi-Node Scale-out Clusters running NetApp Clustered Data ONTAP Silverton Consulting, Inc. StorInt Briefing BENEFITS OF MULTI- NODE SCALE- OUT CLUSTERS RUNNING NETAPP CDOT PAGE 2 OF 7 Introduction

More information

SAN Administration Guide

SAN Administration Guide ONTAP 9 SAN Administration Guide May 2017 215-12156_A0 doccomments@netapp.com Updated for ONTAP 9.2 Table of Contents 3 Contents Deciding whether to use this guide... 6 Setting up your LUN... 7 LUN setup

More information

NDMP in Clustered Data ONTAP for Tape Backup Software Applications

NDMP in Clustered Data ONTAP for Tape Backup Software Applications Technical Report NDMP in Clustered Data ONTAP for Tape Backup Software Applications Subhash Athri, NetApp June 2015 TR-4376 TABLE OF CONTENTS 1 NDMP Backups... 3 1.1 Tape Backup Topologies in Clustered

More information

SMB/CIFS Configuration Guide for Microsoft Hyper-V and SQL Server

SMB/CIFS Configuration Guide for Microsoft Hyper-V and SQL Server ONTAP 9 SMB/CIFS Configuration Guide for Microsoft Hyper-V and SQL Server November 2017 215-11158_E0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this

More information

Disks and Aggregates Power Guide

Disks and Aggregates Power Guide ONTAP 9 Disks and Aggregates Power Guide November 2017 215-11204_F0 doccomments@netapp.com Updated for ONTAP 9.3 Table of Contents 3 Contents Deciding whether to use this guide... 6 Aggregate creation

More information

A. Both Node A and Node B will remain on line and all disk shelves will remain online.

A. Both Node A and Node B will remain on line and all disk shelves will remain online. Volume: 75 Questions Question No: 1 On a FAS8040, which port is used for FCoE connections? A. e0m B. e0p C. 0a D. e0h Answer: D Question No: 2 Click the Exhibit button. Referring to the diagram shown in

More information

Data ONTAP 8.1 Upgrade and Revert/Downgrade Guide for 7-Mode

Data ONTAP 8.1 Upgrade and Revert/Downgrade Guide for 7-Mode IBM System Storage N series Data ONTAP 8.1 Upgrade and Revert/Downgrade Guide for 7-Mode GA32-1034-03 Contents Preface................................ 1 About this guide..............................

More information

Data Protection Guide

Data Protection Guide SnapCenter Software 4.1 Data Protection Guide For VMs and Datastores using the SnapCenter Plug-in for VMware vsphere September 2018 215-13399_B0 doccomments@netapp.com Table of Contents 3 Contents Deciding

More information

Installation and User Guide

Installation and User Guide OnCommand Cloud Manager 3.0 Installation and User Guide For Volume Management September 2016 215-11109_B0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this guide... 4 Product

More information

Clustered Data ONTAP 8.3

Clustered Data ONTAP 8.3 Clustered Data ONTAP 8.3 Volume Disaster Recovery Preparation Express Guide NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support telephone:

More information

Data ONTAP Release Notes

Data ONTAP Release Notes IBM System Storage N series Data ONTAP 7.3.7 Release Notes GC53-1175-25 Contents Data ONTAP 7.3.7 Release Notes....................... 1 About the Data ONTAP 7.3.7 release....................... 1 About

More information

A Thorough Introduction to 64-Bit Aggregates

A Thorough Introduction to 64-Bit Aggregates Technical Report A Thorough Introduction to 64-Bit Aggregates Shree Reddy, NetApp September 2011 TR-3786 CREATING AND MANAGING LARGER-SIZED AGGREGATES The NetApp Data ONTAP 8.0 operating system operating

More information

Data ONTAP 7-Mode Administration

Data ONTAP 7-Mode Administration Data ONTAP 7-Mode Administration Cursusduur: 5 Dagen Cursuscode: D7ADM Beschrijving: This five-day instructor-led course enables you to perform basic support and administrative functions on a NetApp storage

More information

NS Number: NS0-158 Passing Score: 800 Time Limit: 120 min File Version: NS0-158

NS Number: NS0-158 Passing Score: 800 Time Limit: 120 min File Version: NS0-158 NS0-158 Number: NS0-158 Passing Score: 800 Time Limit: 120 min File Version: 1.0 NS0-158 NetApp Certified Data Administrator, ONTAP Version 1.0 Экзамен A QUESTION 1 Click the Exhibit button. You create

More information

Data Fabric Solution for Cloud Backup Workflow Guide Using SnapCenter

Data Fabric Solution for Cloud Backup Workflow Guide Using SnapCenter Data Fabric Solutions Data Fabric Solution for Cloud Backup Workflow Guide Using SnapCenter Using ONTAP, SnapCenter, and AltaVault November 2017 215-12684_A0 doccomments@netapp.com Table of Contents 3

More information

OnCommand System Manager 3.1.1

OnCommand System Manager 3.1.1 OnCommand System Manager 3.1.1 Managing Clustered Data ONTAP Using the GUI Printable Online Help NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501

More information

Clustered Data ONTAP 8.2

Clustered Data ONTAP 8.2 Updated for 8.2.1 Clustered Data ONTAP 8.2 7-Mode Data Transition Using SnapMirror NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support

More information

Abstract. Data Classification. Technical Report. Roy Scaife, NetApp Version March 2016 TR-4375

Abstract. Data Classification. Technical Report. Roy Scaife, NetApp Version March 2016 TR-4375 Technical Report Roy Scaife, NetApp Version 1.2.1 March 2016 TR-4375 Abstract This document provides technical information about NetApp MetroCluster software in the NetApp Data ONTAP 8.3.2 operating system.

More information

OnCommand System Manager 3.1.2

OnCommand System Manager 3.1.2 OnCommand System Manager 3.1.2 Managing Clustered Data ONTAP Using the GUI Printable Online Help NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501

More information

Installation and Cluster Deployment Guide for VMware

Installation and Cluster Deployment Guide for VMware ONTAP Select 9 Installation and Cluster Deployment Guide for VMware Using ONTAP Select Deploy 2.6 November 2017 215-12636_B0 doccomments@netapp.com Updated for ONTAP Select 9.3 Table of Contents 3 Contents

More information

NetApp Clustered Data ONTAP 8.2

NetApp Clustered Data ONTAP 8.2 Technical Report NetApp Clustered Data ONTAP 8.2 An Introduction Charlotte Brooks, NetApp May 2013 TR-3982 Abstract This technical report is an introduction to the architecture and key customer benefits

More information

Clustered Data ONTAP 8.3 Update 2, IPspaces. Self-paced Lab NETAPP UNIVERSITY. NetApp University - Do Not Distribute

Clustered Data ONTAP 8.3 Update 2, IPspaces. Self-paced Lab NETAPP UNIVERSITY. NetApp University - Do Not Distribute NETAPP UNIVERSITY Clustered Data ONTAP 8.3 Update 2, IPspaces Self-paced Lab Course ID: STRSW-SPL-CDOT83UPD2 Content Version: 1.0 ATTENTION The information contained in this course is intended only for

More information

Data ONTAP 8.2 Upgrade and Revert/Downgrade Guide For 7-Mode

Data ONTAP 8.2 Upgrade and Revert/Downgrade Guide For 7-Mode IBM System Storage N series Data ONTAP 8.2 Upgrade and Revert/Downgrade Guide For 7-Mode SC27-5925-03 Contents Preface................................ vii About this guide.............................

More information