ET100A [ver2] Synchronous WAN Ethernet Bridge 10/100Base-TX Ethernet over V.35, X.21, RS-232/530/449

Size: px
Start display at page:

Download "ET100A [ver2] Synchronous WAN Ethernet Bridge 10/100Base-TX Ethernet over V.35, X.21, RS-232/530/449"

Transcription

1 ET100A [ver2] Synchronous WAN Ethernet Bridge 10/100Base-TX Ethernet over V.35, X.21, RS-232/530/449

2

3 CTC Union Technologies Co., Ltd. Neihu Technology Park Vienna Technology Center 8F, No. 60 Zhouzi St. Neihu, Taipei, 114 Taiwan ET100A Ethernet WAN Bridge, User Manual Version 2.1 July 24, 2014 Release This manual supports the following models: ET100A Ethernet WAN Bridge (manufactured after March 2014) All specifications subject to change without notice.

4

5 Table of Contents OVERVIEW... 7 FEATURES... 7 SPECIFICATIONS... 8 THEORY OF OPERATION DIP SWITCH OPERATION SETTINGS WAN PORT PIN ASSIGNMENT...20 CABLE PIN ASSIGNMENTS: RS-530 CABLE, 25 CONDUCTOR ROUND, 1 TO 1, 1M RS-232 CABLE, 12 CONDUCTOR ROUND, 1M V.35 CABLE, MULTI-CONDUCTOR ROUND, 1M RS-449 CABLES, MULTI-CONDUCTOR ROUND, 1M X.21 CABLES, MULTI-CONDUCTOR ROUND, 1M APPLICATION EXAMPLES i

6 Table of Contents This page left blank intentionally. ii

7 Overview ET100A LAN-WAN Bridge The ET100A Network Bridge is a high performance, remote, self-learning Ethernet bridge. Its compact size and low cost make it ideal for cost-sensitive bridging applications, or as a LAN extender or segmenter over bit stream type infrastructures. Several selectable synchronous data interfaces, including V.35, RS-530, RS-449, X.21, and RS-232, make this Ethernet Bridge's connection between 10Base-T and 100Base-TX LAN and various SYNC data port interfaces convenient. Features Supports raw HDLC, Cisco HDLC, and PPP encapsulation 10BASE-T/100BASE-TX, Full Duplex or Half Duplex HP Auto-MDI/MDIX detects and corrects crossed cable Automatic address learning, aging and deletion after 5 minutes Forwarding and filtering rate at wire speed with through put latency of 1 frame. Auto padding of undersized packets to meet the minimum Ethernet packet size requirement 1763 packet buffer Ethernet interface has automatic Twisted Pair polarity correction Built-in nx64k / nx56k timing clock generator for WAN link for speeds up to 10mbps 256 MAC Table Ethernet flow control per IEEE802.3x 7

8 Specifications LAN WAN ET100A LAN-WAN Bridge Standard Fully compliant with IEEE 802.3/802.3u, 802.3x Connector Shielded RJ-45 Speeds 10BASE-T/100BASE-TX, Full or Half Duplex MTU 1536 bytes MAC Table 256 addresses Interface Protocol Buffer Connector Type Data Rates Clock Source General Power Environment Dimensions Weight LED INDICATORS SYNC (green) LINK (green) Rx (green) Tx (green) PWR (green) ERROR (red) ACT (green) LINK (green) Selectable RS-232(SYNC), V.35, RS-449/530, and X.21 Synchronous HDLC, PPP or Cisco HDLC 1763 Packets DB25 Male DTE port n x 64(56)Kbps, up to 10Mbps Internal or External AC Adapter; EUP 100~240VAC / 12VDC-1A Unit; DC9~12V/300mA Temperature: 0~50 o C Humidity: <90% non-condensing 135(L) x 80(W) x 25(H) mm 150g ON=WAN Protocol Up ON=receiving CTS and DSR signal ON=WAN receive data (blinking) ON=WAN transmit data (blinking) ON=Power OK OFF=system OK, 2 pulse=configuration error; 3 pulse=wan CRC OFF=No link; Blinking=receiving data ON=LAN linked; OFF=no link 8

9 Interface Select WAN SIDE DB25-Male DTE RS-530/449 V.35 X.21 RS-232 Serial Port Line Drivers LINK Tx LED Rx LED SYNC SYNC HDLC CONTROLLER Clock Source Ext. clock Int. clock ERROR Full Duplex Half Duplex FILTER ENGINE MAC Address Table Frame Buffer IEEE802.3u I/F LAN SIDE RJ-45 Clock Generator SYNC SPEED N56K to 1792K N64K to 10M ACT LINK LAN Link LED Figure 1: ET100A Functional Block Diagram 9

10 Unit Detail ET100A LAN-WAN Bridge Figure 2. ET100A Unit Detail 10

11 (1) DB25 Male Connector: This connector connects to the appropriate adapter cable for connection to the various supported data interfaces. The ET100A performs in DTE mode and its WAN port connector may be connected directly to a DCE device (such as a modem or DSU/CSU). (2) SYNC LED: Green, where ON indicates protocol is up. If OFF, first make sure physical link is up, then make sure protocol settings match. (3) LINK LED: Green, where ON indicates the presence of CTS / DSR signal on WAN connection. (4) RX LED: Green, on or flashing indicates receiving data on the WAN interface. (5) TX LED: Green, on or flashing indicates transmitting data on the WAN interface. (6) SW1: Configuration setting for the bridge. (Please refer to DIP SW setting table.) (7) SW2: Configuration setting for the bridge. (Please refer to DIP SW setting table.) (8) RJ-45 Ethernet LAN Port: This is an auto-mdi/mdix port for connection to the LAN. 11

12 (9) LINK LED: (LAN) Green, indicates the Ethernet has a link to an external device. (10) ACT LED: (LAN) Green, indicates data being received from the LAN connection. (11) ERROR LED: Red, indicates an error condition as follows: ON - System Error Pulse 2 - Configuration error Pulse 3 - WAN receive has CRC errors (12) PWR LED: Green on, when external power adapter is plugged in and AC power is supplied to it. (13) DC 9~12V This jack receives power from the external DC 12V AC power switching adapter. The center pin is positive voltage. 12

13 Theory of Operation A bridge is used to connect networks locally or remotely such that they appear to the user to be the same network. An Ethernet LAN bridge will connect two LAN segments at the Data Link Layer (ISO Layer 2). At this layer, the MAC (Media Access Control) addresses, are used for low level addressing to send information to devices. The bridge builds tables of MAC addresses for each network segment based on the source and destination addresses of the packets it receives and forwards, then filters the traffic not destined for the remote network. The Ethernet-WAN bridge will connect two remote Ethernet networks over bit stream interfaces such as that of synchronous modems or DSU/CSUs. One method to do this is to use HDLC, an international standard set by the ISO, a set of protocols for carrying data over a link with error and flow control. Another method uses PPP and a third uses Cisco HDLC. The ET100A utilizes both Ethernet Bridging and encapsulation to provide a connection between LANs over bit stream architectures. The LAN side of the ET100A receives an Ethernet packet and examines its destination MAC address. If it knows the MAC is on the local network then it simply drops the packet. Otherwise, if it knows the packet destination is on the remote side, or if it cannot be determined because its MAC cannot be found in the table, then it forwards it. During forwarding, the packet is processed for transmission across the WAN link. Here is where the Ethernet packet in encapsulated. 13

14 When the HDLC or PPP packet is received on the remote side unit's data port, the packet is checked for transmission errors, then the original Ethernet packet(s) is recovered and sent out the remote's LAN port completing the transmission. Here is the typical application of the ET100A. ET100A/V35 ET100A/V35 Figure 3. Typical application of ET100A LAN-WAN Bridge. Many times the ET100A is commonly referred to as an Ethernet to V.35, Ethernet to X.21, or Ethernet to Datacom 'converter'. As a sales/marketing term or non-technical reference, the term is OK. However, from a technical standpoint, the term is a misnomer. The Ethernet is not "converted" to V.35, it is run "over" the V.35 link. Conversion also implies that the interface can work both ways. This is NOT the case for the LAN-WAN Bridge as the following application shows. ET100A/V35 ET100A/V35 Figure 4. Application NOT ALLOWED for ET100A. 14

15 Why does the previous application not work? It won't work because the application requires a bit stream to be encapsulated into Ethernet packets, or into TCP/IP and then Ethernet, for transmission across the LAN. This requires more than just manipulation at the Data Link layer (ISO Layer 2), it requires programming to include all seven layers including the Application layer. Transmitting bit stream or TDM (time division multiplexed) data over Ethernet requires a device such as an IP-Multiplexer. Please refer to the "Applications" section at the end of this manual for additional application examples. 15

16 NC (Reserved for future use) ET100A LAN-WAN Bridge DIP Switch Operation Settings SW1 Operation Settings SW Function OFF ON HDLC ON OFF Cisco HDLC OFF OFF PPP OFF External WAN clock ON Internal WAN clock DTR follows DSR. OFF RTS follows CTS. DTR & RTS always ON ON LAN IEEE802.3x OFF Enable LAN IEEE802.3x ON Disable LAN OFF Auto-Negotiation Enable ON OFF OFF 100M/Full Duplex ON OFF ON 100M/Half Duplex ON ON OFF 10M/Full ON ON ON 10M/Half SW2 WAN Interface Settings Table 1: SW1 Operation Settings SW2 DIP 1 2 WAN INTERFACE TYPE OFF OFF V.35 ON OFF RS-530/RS-449/X.21 ON ON RS-232 Table 2: SW2 WAN Interface Type 16

17 SW2 WAN Speed Type ET100A LAN-WAN Bridge SW2 DIP 8 9 WAN SPEED TYPE OFF OFF 64K~2048K (N 64K) ON OFF 56K~1792K (N 56K) OFF ON 2176K~6144K (HS-1) ON ON 6272K~10240K (HS-2) SW2 WAN Clock Baud Rate Table 3: SW2 WAN Speed Type RATE SW2 DIP BAUD RATE NO N 64K N 56K HS-1 HS-2 1 OFF OFF OFF OFF OFF 64K 56K 2176K 6272K 2 ON OFF OFF OFF OFF 128K 112K 2304K 6400K 3 OFF ON OFF OFF OFF 192K 168K 2432K 6528K 4 ON ON OFF OFF OFF 256K 224K 2560K 6656K 5 OFF OFF ON OFF OFF 320K 280K 2688K 6784K 6 ON OFF ON OFF OFF 384K 336K 2816K 6912K 7 OFF ON ON OFF OFF 448K 392K 2944K 7040K 8 ON ON ON OFF OFF 512K 448K 3072K 7168K 9 OFF OFF OFF ON OFF 576K 504K 3200K 7296K 10 ON OFF OFF ON OFF 640K 560K 3328K 7424K 11 OFF ON OFF ON OFF 704K 616K 3456K 7552K 12 ON ON OFF ON OFF 768K 672K 3584K 7680K 13 OFF OFF ON ON OFF 832K 728K 3712K 7808K 14 ON OFF ON ON OFF 896K 784K 3840K 7936K 15 OFF ON ON ON OFF 960K 840K 3968K 8064K 16 ON ON ON ON OFF 1024K 896K 4096K 8192K 17 OFF OFF OFF OFF ON 1088K 952K 4224K 8320K 18 ON OFF OFF OFF ON 1152K 1008K 4352K 8448K 19 OFF ON OFF OFF ON 1216K 1064K 4480K 8576K 20 ON ON OFF OFF ON 1280K 1120K 4608K 8704K 21 OFF OFF ON OFF ON 1344K 1176K 4736K 8832K 22 ON OFF ON OFF ON 1408K 1232K 4864K 8960K 23 OFF ON ON OFF ON 1472K 1288K 4992K 9088K 24 ON ON ON OFF ON 1536K 1344K 5120K 9216K 25 OFF OFF OFF ON ON 1600K 1400K 5248K 9344K 26 ON OFF OFF ON ON 1664K 1456K 5376K 9472K 27 OFF ON OFF ON ON 1728K 1512K 5504K 9600K 28 ON ON OFF ON ON 1792K 1568K 5632K 9728K 29 OFF OFF ON ON ON 1856K 1624K 5760K 9856K 30 ON OFF ON ON ON 1920K 1680K 5888K 9984K 31 OFF ON ON ON ON 1984K 1736K 6016K 10112K 32 ON ON ON ON ON 2048K 1792K 6144K 10240K Table 4: SW2 WAN Clock Baud Rate 17

18 NOTE 1: When the ET100A is set to internal WAN clock, SW2-3 to SW2-9 provision the baud rate. If WAN clock is set external, these are ignored. NOTE 2: After changing the DIP switch setting, you must restart the device to activate the setting. When the ET100A leaves the factory, all DIP switch settings are set to the OFF position. Auto-negotiation: When this feature is enabled (SW1-6=OFF), the Speed (SW1-7) and Duplex (SW1-8) settings are ignored and are automatically determined from the LAN connection. When this feature is disabled (SW1-6=ON), the Duplex and Speed settings of the LAN follow the settings of SW1-7 and SW1-8. Use forced mode with caution to avoid Duplex Mismatch. Protocol Selection: The ET100A supports selecting one of three encapsulation protocols. When selecting HDLC, the encapsulation is per ISO The chdlc encapsulation is compatible with Cisco modified HDLC. The PPP encapsulation follows RFC1661 and is also a very popular encapsulation protocol. The protocol selection is controlled by the setting of DIP switches SW1-1 and SW1-2. Clock Selection: The ET100A inherently acts as a DTE device. A 1:1 cable is used to connect to a DCE device such as a modem, CSU/DSU or data multiplexer. Clock source comes from the DCE so the clock setting is usually external (SW1-4 OFF). The ET100A is also capable of acting as a DCE. In this case a 18

19 crossover cable is required and clock setting (SW1-4 ON) is internal. Data rate is then set by SW2, 3~9 and ET100A provides clock source. LAN Flow Control: The ET100A LAN port supports IEEE802.3x flow control, which can help to regulate the higher speed LAN traffic that hits the bottle neck of the slower WAN speed. Without flow control, the LAN packets that exceed the WAN speed will be dropped and the resulting timeout caused must be handled by the application layer. LAN Auto Negotiation: The ET100A LAN port supports auto-negotiation per IEEE802.3u. When auto negotiation is enabled and the LAN port connects to another auto negotiation compliant port, the LAN speed will be auto detected while the Duplex should be negotiated to Full Duplex. When connecting to legacy equipment, it may be necessary to 'force' the speed and Duplex on the LAN port. Care must be taken here to avoid a Duplex Mismatch condition when a 'forced' port connects to an 'auto' port. Without negotiation, an 'auto' port will revert to Half Duplex per the IEEE802.3u standard. A Duplex Mismatch condition could result in extremely poor network performance. WAN Interface Selection: The ET100A has selectable hardware interface circuits. When set to X.21/RS-530/RS-449, the logic, clock and handshaking signals all follow RS-422 electrical (balanced signals). When set to RS-232, all signals become single ended and follow RS-232D signal levels. When configured as V.35, the logic and clock signals follow RS-422 electrical, while handshaking signals are RS-232 electrical. 19

20 WAN Port Pin Assignment The following tables give the pin, circuit, function and signal direction as seen on the ET100A's DB25M connector for each of the selectable interfaces. RS-232 and RS-530 connections may be made directly. Adapter cables are required to match the physical connectors for V.35 (MB34), X.21 (DB15) and RS-449 (DB37). a. RS-232 INTERFACE PIN ASSIGNMENT (SYNC) PIN CIRCUIT FUNCTION DIRECTION EIA 2 TD Transmit data OUT BA 3 RD Receive data IN BB 4 RTS Request to send OUT CA 5 CTS Clear to send IN CB 6 DSR Data set ready IN CC 7 GND Signal ground AB 8 DCD Carrier detect IN CF 15 TC Transmit clock IN DB 17 RC Receive clock IN DD 20 DTR Data term ready OUT CD 24 XTC DTE xmit clock OUT DA Table 5: RS-232 Interface Pin Assignment SW2-1/2 ON/ON 20

21 b. V.35 INTERFACE PIN ASSIGNMENT PIN CIRCUIT FUNCTION DIRECTION CCITT 1 FGND Protective GND TD(A) Xmit data A OUT RD(A) Receive data A IN RTS Request to send OUT CTS Clear to send IN DSR Data set ready IN GND Signal ground DCD Data carrier detect IN RC(B) Receive clock B IN XTC(B) DTE Xmit clock B OUT TC(B) Xmit clock B IN TD(B) Xmit data B OUT TC(A) Xmit clock A IN RD(B) Receive data B IN RC(A) Receive clock A IN DTR Data terminal ready OUT XTC(A) DTE Xmit clock A OUT 113 Table 6: V.35 Interface Pin Assignment SW2-1/2 OFF/OFF 21

22 c. RS-449/RS-530 INTERFACE PIN ASSIGNMENT PIN CIRCUIT FUNCTION DIRECTION CCITT 1 FGND Protective GND SD(A) Xmit data A OUT RD(A) Receive data A IN RS(A) Request to send A OUT CS(A) Clear to send A IN DM(A) Data set ready A IN GND Signal ground RR(A) Data carrier detect A IN RT(B) Receive clock B IN RR(B) Data carrier detect B IN TT(B) DTE Xmit clock B OUT ST(B) Xmit clock B IN CS(B) Clear to send B IN SD(B) Xmit data B OUT ST(A) Xmit clock A IN RD(B) Receive data B IN RT(A) Receive clock A IN RS(B) Request to send B OUT TR(A) Data terminal ready A OUT DM(B) Data set ready B IN TR(B) Data terminal ready B OUT TT(A) DTE Xmit clock A OUT 113 Table 7: RS-449/RS-530 INTERFACE PIN ASSIGNMENT SW2-1/2 ON/OFF 22

23 d. X.21 INTERFACE PIN ASSIGNMENT PIN CIRCUIT FUNCTION DIRECTION CCITT 1 FGND Protective GND T(A) Xmit data A OUT R(A) Receive data A IN C(A) Request to send A OUT GND Signal ground I(A) Data carrier detect A IN S(B) Receive clock B IN I(B) Data carrier detect B IN T(B) Xmit data B OUT R(B) Receive data B IN S(A) Receive clock A IN C(B) Request to send B OUT 105 Table 8: X.21 INTERFACE PIN ASSIGNMENT SW2-1/2 ON/OFF 23

24 Cable Pin Assignments: RS-530 Cable, 25 conductor round, 1 to 1, 1m. (This cable may be used for RS-232 applications as well.) Part#:58-D2FD2M007, RS-530 Cable, DB25 Female <=> DB25 Male, 1 Meter DB25(Female) DB25(Male-DTE) PIN PIN Circuit Name 1 <===========> 1 Shield 7 <===========> 7 Signal Gnd 2 <===========> 2 BA - TD(A) 14 <===========>14 BA - TD(B) 3 <===========> 3 BB - RD(A) 16 <===========> 16 BB - RD(B) 4 <===========> 4 CA - RTS(A) 19 <===========> 19 CA - RTS(B) 5 <===========> 5 CB - CTS(A) 13 <===========> 13 CB - CTS(B) 6 <===========> 6 CC - DSR(A) 22 <===========> 22 CC - DSR(B) 20 <===========> 20 CD - DTR(A) 23 <===========> 23 CD - DTR(B) 8 <===========> 8 CF - DCD(A) 10 <===========> 10 CF - DCD(B) 15 <===========> 15 DB - TC(A) 12 <===========> 12 DB - TC(B) 17 <===========> 17 DD - RC(A) 9 <===========> 9 DD - RC(B) 24 <===========> 24 DA - XTC(A) 11 <===========> 11 DA - XTC(B) 21 <===========> 21 RL 18 <===========> 18 LL 25 <===========> 25 TM NOTE: "A" and "B" signals must be twisted pair 24

25 RS-232 Cable, 12 conductor round, 1m. (Use this cable for pure RS-232 applications.) Part#:58-xxxxxxxx, RS-232 Cable, DB25 Female <=> DB25 Male, 1 Meter DB25(Female) DB25(Male-DTE) PIN PIN Circuit Name 1 <===========> 1 Shield (AA) 7 <===========> 7 Signal Gnd (AB) 2 <===========> 2 TD (BA) 3 <===========> 3 RD (BB) 4 <===========> 4 RTS (CA) 5 <===========> 5 CTS (CB) 6 <===========> 6 DSR (CC) 8 <===========> 8 DCD (CF) 20 <===========> 20 DTR (CD) 15 <===========> 15 TC (DB) 17 <===========> 17 RC (DD) 24 <===========> 24 XTC (DA) 25

26 V.35 Cable, multi-conductor round, 1m. Part#:58-D2FM3M001, V.35 Cable, DB25 Female MB34 Male, 1 Meter NOTE: TWISTED PAIRS; P,S R,T U,W Y,AA V,X DB25(Female) MB34(Male-DTE) PIN PIN Circuit Name 2 <===========> P TD(A) 14 <===========> S TD(B) 3 <===========> R RD(A) 16 <===========> T RD(B) 4 <===========> C RTS 5 <===========> D CTS 6 <===========> E DSR 20 <===========> H DTR 8 <===========> F DCD 24 <===========> U XTC(A) 11 <===========> W XTC(B) 15 <===========> Y TC(A) 12 <===========> AA TC(B) 17 <===========> V RC(A) 9 <===========> X RC(B) 1 <===========> A Shield 7 <===========> B Signal Gnd 22 <===========> J RI 26

27 RS-449 Cables, multi-conductor round, 1m. Part#:58-D2FD3M003, RS-449 Cable, DB25 Female DB37 Male, 1M DB25(Female) DB37(Male-DTE) PIN PIN Circuit Name 1 <===========> 1 Shield 7 <===========> 19,37,20 Signal Gnd (the following are all twisted pairs) 2 <===========> 4 SD(A) 14 <===========> 22 SD(B) 3 <===========> 6 RD(A) 16 <===========> 24 RD(B) 4 <===========> 7 RS(A) 19 <===========> 25 RS(B) 5 <===========> 9 CS(A) 13 <===========> 27 CS(B) 6 <===========> 11 DM(A) 22 <===========> 29 DM(B) 20 <===========> 12 TR(A) 23 <===========> 30 TR(B) 8 <===========> 13 RR(A) 10 <===========> 31 RR(B) 24 <===========> 17 TT(A) 11 <===========> 35 TT(B) 15 <===========> 5 ST(A) 12 <===========> 23 ST(B) 17 <===========> 8 RT(A) 9 <===========> 26 RT(B) NOTE: "A" and "B" signals must be twisted pair 27

28 X.21 Cables, multi-conductor round, 1m. Part#:58-xxxxxxxx, X.21 Cable, DB25 Female DB15 Male, 1M DB25(Female) DB15(Male-DTE) PIN PIN Circuit Name 1 <===========> 1 Shield 7 <===========> 8 Ground 2 <===========> 2 T(A) 14 <===========> 9 T(B) 3 <===========> 4 R(A) 16 <===========> 11 R(B) 4 <===========> 3 C(A) 19 <===========> 10 C(B) 5,6 <===========> 5 I(A) 13,22 <===========> 12 I(B) 15,17 <===========> 6 S(A) 12,9 <===========> 13 S(B) NOTE: "A" and "B" signals must be twisted pair 28

29 Application Examples In the following example, the ET100A is configured for bridging over an E1 (or T1) carrier provider's network. The ET100A's interface is set to V.35 to match the CSU/DSU unit. The CSU/DSU may be set unframed or may be set to use a fraction (n x 56 or n x 64) of the E1 (or T1) line. The CSU/DSU timing is received from the carrier provider's network so the ET100A's timings for Tx and Rx clocks should be set to external. In this configuration, the rate DIP settings of the ET100A are ignored. ET100A/V35 ET100A/V35 Figure 5: Bridging over E1 services 29

30 APPLICATIONS In the next example, the ET100A is setup to bridge over a PSTN's leased line. The ET100A's speed settings depend upon the speed of the leased line and the settings of the modems. The timing scheme recommended is this application is for the Tx and Rx Clocks of each unit to be set to External while the clocks of the modems are set to Internal for both or Internal for one and Loop for the other. ET100A/232 ET100A/232 Figure 6: Bridging over Synchronous leased line. 30

31 APPLICATIONS In the following example, the ET100A is paired with a G703/64K interface converter to provide connection over G Kbps services. If the G.703 transmit and receive clocks are provided by the central carrier, each G703/64K converter will be set to centra-directional line timing. Both ET100A's will have their Tx / Rx clocks set external. Figure 7: ET100A bridge over G K services. 31

32 This page left blank intentionally. 32

33 CTC Union Technologies Inc Attn : Technical Support Department From Company: Name: Tel: ( ) Fax:( ) Fax:(886) Tel:(886) techsupport@ctcu.com Taipei Taiwan MODEL: ET100A ACTIVITY: As attached in DIP switch setting table SYS CONFIGURATION: Question

34 Technical Inquiry Form MODEL No.: ET100A Please fill in the DIP switches configuration with ' ' marks into the following table. Send it to us by fax, and we will reply to you immediately. SW NO. DIP FUNCTION SW1 1 Protocol Selection 2 Protocol Selection 3 WAN Clock Source 4 CTS/DSR - DCD 5 LAN Flow Control (802.3x) 6 Auto / Forced 7 10M / 100M 8 Full / Half Duplex (manual) 9 NA (reserved) SW2 1 WAN I/F Type 2 WAN I/F Type 3 WAN Clock Rate (Internal) 4 WAN Clock Rate (Internal) 5 WAN Clock Rate (Internal) 6 WAN Clock Rate (Internal) 7 WAN Clock Rate (Internal) 8 WAN Clock Rate (Internal) 9 WAN Clock Rate (Internal) Your Setting CTC Suggestion ON OFF ON OFF Additional comments/questions:

35

36

Table of Contents SPECIFICATIONS...4 THEORY OF OPERATION...9 DIP SWITCH SETTING TABLES:...12 WAN PORT PIN ASSIGNMENT...15 CABLE PIN ASSIGNMENTS:...

Table of Contents SPECIFICATIONS...4 THEORY OF OPERATION...9 DIP SWITCH SETTING TABLES:...12 WAN PORT PIN ASSIGNMENT...15 CABLE PIN ASSIGNMENTS:... 1 Table of Contents OVERVIEW...3 FEATURES...3 SPECIFICATIONS...4 THEORY OF OPERATION...9 DIP SWITCH SETTING TABLES:...12 WAN PORT PIN ASSIGNMENT...15 CABLE PIN ASSIGNMENTS:...19 RS 530 CABLE, 25 CONDUCTOR

More information

INSTALLATION and OPERATION MANUAL

INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL Table of Contents Overview and Features.. 1 Specifications 2 Functional Block Diagram 3 Unit Detail. 4 DIP Switch Setting Tables 7 RS-232 I/F Pin Assignment.. 10 V.35

More information

ET100/NRZ. Ethernet WAN Bridge. 10/100Base-TX Ethernet over NRZ

ET100/NRZ. Ethernet WAN Bridge. 10/100Base-TX Ethernet over NRZ ET100/NRZ Ethernet WAN Bridge 10/100Base-TX Ethernet over NRZ CTC Union Technologies Co., Ltd. NeiHu Hi-Tech Park 8F, No. 60 Zhouzi Street. Neihu, Taipei, 114 Taiwan ET100/NRZ Ethernet WAN Bridge, User

More information

GYM Bilgi Teknolojileri

GYM Bilgi Teknolojileri www.fibridge-tr.com bilgi@gym-tech.net GYM Bilgi Teknolojileri E1 and V.35 Modem User Manual (Version 1.0) Beijing Fibridge Co., Ltd Table of Content 1. Overview... 1 2. Features... 1 3. Specification...

More information

USER MANUAL E1U-ET100. Ethernet over Unframed E1 Bridge Line Card For ERM01

USER MANUAL E1U-ET100. Ethernet over Unframed E1 Bridge Line Card For ERM01 USER MANUAL E1U-ET100 Ethernet over Unframed E1 Bridge Line Card For ERM01 CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60, Zhouzi St. Neihu, Taipei,

More information

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter ICD105A 1008 page 1/5 7319 r001 ICD105A Industrial RS-232 to RS-422/485 Converter Data Rates up to 115.2 Kbps 10 48 VDC Input Power Range Wide Operating Temperature 3-Way 2000V Optical Isolation Modbus

More information

USER MANUAL G703/64-RM. G Kbps Co-Directional Rack Mount 1 to 13 Ports or 12 Ports + SNMP

USER MANUAL G703/64-RM. G Kbps Co-Directional Rack Mount 1 to 13 Ports or 12 Ports + SNMP USER MANUAL G703/64-RM G.703 64Kbps Co-Directional Rack Mount 1 to 13 Ports or 12 Ports + SNMP Table of Contents Chapter 1. Introduction... 1 1.1 General.. 1 1.2 Functional Description. 1 1.3 Technical

More information

Miniature Asynchronous 4-Wire High Speed Modems

Miniature Asynchronous 4-Wire High Speed Modems ME1862A-F ME1863A-F JULY 2003 ME1862A-M ME1863A-M Miniature Asynchronous 4-Wire High Speed Modems CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)

More information

USER MANUAL EOe-1. 10/100Base Ethernet over G.703 Unframed E1

USER MANUAL EOe-1. 10/100Base Ethernet over G.703 Unframed E1 USER MANUAL EOe-1 10/100Base Ethernet over G.703 Unframed E1 CTC Union Technologies Co., Ltd. Far Eastern Vienna Building Neihu Technology Park 8F, No. 60 ZhouZi St. Neihu, Taipei, 114 Taiwan EOe-1 Ethernet

More information

xdsl Bridge WireSpan 5100B Installation Guide ATRIE TECHNOLOGY INC. (Version 1.00)

xdsl Bridge WireSpan 5100B Installation Guide ATRIE TECHNOLOGY INC. (Version 1.00) xdsl Bridge Installation Guide (Version 1.00) ATRIE TECHNOLOGY INC. 10F, No.1, Lane 609, Sec. 5, Chung Hsin Rd., San Chung City, Taipei Hsien, Taiwan, R.O.C. Tel : (886)-999-5155 Fax : (886)-999-960 Website

More information

Copyright Black Box Corporation. All rights reserved.

Copyright Black Box Corporation. All rights reserved. Copyright 1998. Black Box Corporation. All rights reserved. 1000 Park Drive Lawrence, PA 150551018 7247465500 Fax 7247460746 SAM232 Compact MARCH 1998 TS158A DB 9P cable test 1 5 6 8 7 2 3 9 4 7 6 5 4

More information

STEP X - Name of Step QUICK START GUIDE SP385A-R3, SP390A-R3 USB TO RS CONVERTER 24/7 TECHNICAL SUPPORT AT OR VISIT BLACKBOX.

STEP X - Name of Step QUICK START GUIDE SP385A-R3, SP390A-R3 USB TO RS CONVERTER 24/7 TECHNICAL SUPPORT AT OR VISIT BLACKBOX. STEP X - Name of Step QUICK START GUIDE SP385A-R3, SP390A-R3 USB TO RS CONVERTER 24/7 TECHNICAL SUPPORT AT 877.877.2269 OR VISIT BLACKBOX.COM STEP 1 - Package Includes/System Requirements PACKAGE INCLUDES

More information

ERM-Mux/Plus. 4U, 10 I/O Slot Data, Ethernet, Voice E1 Managed Multiplexer. E1 Access Multiplexer. ERM-Mux/Plus.

ERM-Mux/Plus. 4U, 10 I/O Slot Data, Ethernet, Voice E1 Managed Multiplexer. E1 Access Multiplexer. ERM-Mux/Plus. Access Multiplexer 4U, 10 I/O Slot Data,, Voice Managed Multiplexer The ERM-Mux/plus is a 4U 19(23)" 14 slot rack type Time Division Multiplexer for Fractional network access which is designed for non-stop

More information

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology 485DRCI RS-232 RS-485 2-Wrie RS-422/485 4-Wire RS-232 CON. RS-422/485 CON. Data Rate Isolation Surge Protection Industrial Bus Source Input Voltage Power Consumption Connector p/n 7207r3 485DRCI-4108ds

More information

ICD200A Quick Start Guide. Convert RS-232 data signals to RS-422/485 signals in heavy industrial areas.

ICD200A Quick Start Guide. Convert RS-232 data signals to RS-422/485 signals in heavy industrial areas. Industrial Opto-Isolated RS-232 to RS-422/485 Converter Convert RS-232 data signals to RS-422/485 signals in heavy industrial areas. Rugged IP30-rated metal case for panel mounting. Quick Start Guide Customer

More information

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options: FEATURES E1 or Fractional E1 access unit Supports one data port with selectable sync data rates: n x 56, n x 64 kbps Optional sub-e1 drop & insert port for PABX connectivity Single slot supports MEGAPLEX

More information

Installation and Operation Manual. Ethernet Interface for SIMREX Radio Modems. SIMREX P/N: MAN.UBRIDGE Rev. B APRIL 2005

Installation and Operation Manual. Ethernet Interface for SIMREX Radio Modems. SIMREX P/N: MAN.UBRIDGE Rev. B APRIL 2005 Installation and Operation Manual SIMREX Corporation ubridge Ethernet Interface for SIMREX Radio Modems SIMREX P/N: MAN.UBRIDGE Rev. B APRIL 2005 SIMREX CORPORATION Your Trusted Wireless Solution Provider

More information

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO F8016 Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO Description The fiber transmission platform is a fiber optic multiplexer with a fully new designing concept to challenge

More information

ERM-MUX/Plus E1 Multi-Service Access Multiplexer

ERM-MUX/Plus E1 Multi-Service Access Multiplexer ERM-MUX/Plus E1 Multi-Service Access Multiplexer LEGAL The information in this publication has been carefully checked and is believed to be entirely accurate at the time of publication. CTC Union Technologies

More information

User Manual FRM301 Fiber Media Platform Rack 16 Slot, 3U, Manageable

User Manual FRM301 Fiber Media Platform Rack 16 Slot, 3U, Manageable User Manual FRM301 Fiber Media Platform Rack 16 Slot, 3U, Manageable CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St. Neihu District

More information

MODEL DSU Kbps Rack Mount CSU/DSU OPERATOR S MANUAL. 280 I-80 West Exit 1 PO Box 1330 Verdi NV 89439

MODEL DSU Kbps Rack Mount CSU/DSU OPERATOR S MANUAL. 280 I-80 West Exit 1 PO Box 1330 Verdi NV 89439 MODEL DSU-56 56 Kbps Rack Mount CSU/DSU OPERATOR S MANUAL 280 I-80 West Exit 1 PO Box 1330 Verdi NV 89439 TEL: 775-345-8000 FAX: 775-345-8010 E-MAIL: SUPPORT @S.NET DSU-56 Rack Mount TABLE OF CONTENTS

More information

Product Overview. Interface Converters and Plug-in Modules

Product Overview. Interface Converters and Plug-in Modules Multi Data Digital Product Overview Interface Converters and Plug-in Modules (Ver. 2006/06) MDD - Multi Data Digital GmbH Kaiser-Friedrich-Promenade 37 61348 Bad Homburg Deutschland/Germany Tel: +49 (0)

More information

Sender Receiver Sender

Sender Receiver Sender EEE 410 Microprocessors I Spring 04/05 Lecture Notes # 19 Outline of the Lecture Interfacing the Serial Port Basics of Serial Communication Asynchronous Data Communication and Data Framing RS232 and other

More information

USER MANUAL FOM02-MUX

USER MANUAL FOM02-MUX USER MANUAL FOM02-MUX Fiber Optical Multiplexer Standalone / Rack Type 4, 8, 12 or 16 Channel Modular Design G.703 E1, T1(DS1) Datacom V.35, X.21, RS-530, RS-449, RS-232 Ethernet 10/100Base-TX Bridge SNMP

More information

User Manual A08. User Manual

User Manual A08. User Manual A08 TABLE OF CONTENTS TABLE OF CONTENTS... 1 1. INTRODUCTION... 2 1.1. Key Features... 3 1.2. OS Requirement... 4 1.3. Specification... 4 1.4. Packing List... 4 2. OVERVIEW... 5 2.1. LED Definition...

More information

High performance access device

High performance access device High performance access device qbridge User s Manual qbridge-106 G.SHDSL Modem / Bridge Moscow 2007 2 qbridge-106. G.SHDSL Modem/Bridge. User s Manual v.3 Contents Revision history...3 1. Introduction...4

More information

1205P MODEM ELIMINATOR, V.35 INSTALLATION AND OPERATIONS MANUAL. Doc #: UA Part #: 07M1205P-A (CTS ME-V.35)

1205P MODEM ELIMINATOR, V.35 INSTALLATION AND OPERATIONS MANUAL. Doc #: UA Part #: 07M1205P-A (CTS ME-V.35) Doc #: Part #: 07M1205P-A MODEM ELIMINATOR, V.35 1205P (CTS ME-V.35) INSTALLATI AND OPERATIS MANUAL An ISO-9001 Certified Company Copyright 2000 Patton Electronics Co., All Rights Reserved PATT ELECTRICS

More information

TRP-C37M User s Manual

TRP-C37M User s Manual TRP-C37M User s Manual MODBUS TCP to RTU/ASCII Gateway Printed OCT. 2010 Rev 1.0 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191, Fax: 886-2-86781172

More information

Route 56. PCI USER MANUAL

Route 56. PCI USER MANUAL R Route 56. PCI USER MANUAL Sealevel Systems, Inc P.O. Box 830 Liberty, SC 29657 USA Part # 5101 Phone: (864) 843-4343 FAX: (864) 843-3067 www.sealevel.com Contents INTRODUCTION... 1 OVERVIEW... 1 WHAT

More information

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function Appendix A Specifications This appendix lists the specifications for the BANDIT family of products. Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200

More information

FOM01-MUX. User Manual

FOM01-MUX. User Manual FOM01-MUX User Manual The information contained in this document is subject to change without prior notice. TRADEMARKS Microsoft is a registered trademark of Microsoft Corp. HyperTerminal is a registered

More information

VDTU2-B110 VDSL2 LAN Extender

VDTU2-B110 VDSL2 LAN Extender VDTU2-B110 VDSL2 LAN Extender 1 Copyright by CTC UNION Communications Inc., all right reserved The information in this document has been checked carefully and is believed to be correct as of the date of

More information

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 1018 High Speed Short Range Modem w/ Extra Controls Part# 07M1018-B Doc# 013021UB Revised 11/3/95 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0 WARRANTY INFORMATION

More information

485DRCI. Industrial RS-232 to RS-422/485 Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

485DRCI. Industrial RS-232 to RS-422/485 Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology 485DRCI Industrial RS-232 to RS-422/485 Converter p/n 7207r5 485DRCI-2212ds page 1/5 Data Rates up to 115.2 Kbps 10 48 VDC Input Power Range Wide Operating Temperature 3-Way 2000V Optical Isolation Modbus

More information

Contents INTRODUCTION...1 CARD SETUP...2 INSTALLATION TECHNICAL DESCRIPTION SPECIFICATIONS... 14

Contents INTRODUCTION...1 CARD SETUP...2 INSTALLATION TECHNICAL DESCRIPTION SPECIFICATIONS... 14 Contents INTRODUCTION...1 OVERVIEW...1 WHAT S INCLUDED...1 FACTORY DEFAULT SETTINGS...1 CARD SETUP...2 ADDRESS SELECTION...2 IRQ SELECTION...3 INTERRUPT MODES...4 RS-485 ENABLE MODES...5 CONNECTOR PIN

More information

Contents INTRODUCTION...1 CARD SETUP...2 INSTALLATION...9 TECHNICAL DESCRIPTION SPECIFICATIONS... 13

Contents INTRODUCTION...1 CARD SETUP...2 INSTALLATION...9 TECHNICAL DESCRIPTION SPECIFICATIONS... 13 Contents INTRODUCTION...1 OVERVIEW...1 WHAT S INCLUDED...1 FACTORY DEFAULT SETTINGS...1 CARD SETUP...2 PORT ENABLE / DISABLE...3 IRQ SELECTION...3 INTERFACE SELECTION...4 E2 JUMPER SETTINGS...4 E1 Jumper

More information

APPLICATION NOTE. Product Application Note: APN032

APPLICATION NOTE. Product Application Note: APN032 APPLICATION NOTE Maximise port density and increase data rates when routing asymmetric Ethernet links via satellite modems. The Application Summary With the explosive worldwide growth of the Internet,

More information

Serial Communication Converters & Adapters Instruction Manual

Serial Communication Converters & Adapters Instruction Manual Serial Communication Converters & Adapters Instruction Manual RS-232 to RS-422/485 Converter Isolated RS-232 to RS-422/485 Converter USB to RS-232 Converter USB to RS-422/485 Converter Isolated USB to

More information

Atrie WireSpan 620. User's Manual

Atrie WireSpan 620. User's Manual Atrie WireSpan 620 User's Manual WireSpan 620 Fractional E1/Ethernet Access Unit Installation and Operation Manual (Version 1.00) CONTENTS CHAPTER 1 Introduction.. 1-1 CHAPTER 2 Installation and Setup..

More information

USER MANUAL Fiber Optical Multiplexer Standalone / Rack Type 4, 8, 12 or 16 Channel

USER MANUAL Fiber Optical Multiplexer Standalone / Rack Type 4, 8, 12 or 16 Channel USER MANUAL FMUX-01 Fiber Optical Multiplexer Standalone / Rack Type 4, 8, 12 or 16 Channel G.703 E1, T1(DS1) Datacom V.35, X.21, RS-530, RS-449, RS-232 Ethernet 10/100Base-TX Bridge SNMP Manageable The

More information

USER MANUAL. MODEL 1052 idsl Modem with RS-232 Interface. An ISO-9001 Certified Company SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1052 idsl Modem with RS-232 Interface. An ISO-9001 Certified Company SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 1052 idsl Modem with RS-232 Interface An ISO-9001 Certified Company Part# 07M1052-B Doc# 058061UB Revised 5/24/02 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 TABLE OF

More information

Miniature Asynchronous Modems

Miniature Asynchronous Modems ME615A MARCH 2007 ME615AE ME616A ME616AE Miniature Asynchronous Modems CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support

More information

DATA CONNECT ENTERPRISE

DATA CONNECT ENTERPRISE DATA CONNECT ENTERPRISE User s Manual IG202T and IGV23 Modem Document Number 520-01005-001 Rev. A DATA CONNECT Contents Contents... iii Figures... iv Chapter 1 Introduction... 5 Features...6 Applications...7

More information

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X EtherSeries EtherSeries CR-2 & CR-2-Opto User s Guide Revised October 7, 2013 Firmware Version 1.X TABLE OF CONTENTS SECTION 1 - DESCRIPTION... 2 SECTION 2 - SPECIFICATIONS... 4 SECTION 3 - INSTALLATION...

More information

UNC20 Module. User's Manual. D Breisach, Germany D Breisach, Germany Fax +49 (7667)

UNC20 Module. User's Manual. D Breisach, Germany D Breisach, Germany Fax +49 (7667) UNC20 Module User's Manual P.O: Box 1103 Kueferstrasse 8 Tel. +49 (7667) 908-0 sales@fsforth.de D-79200 Breisach, Germany D-79206 Breisach, Germany Fax +49 (7667) 908-200 http://www.fsforth.de Copyright

More information

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO F8008 Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet + optional V.35/QFXS/QFXO Description F8008 is a fiber optical multiplexer of new generation different from the traditional PDH, multiplexing 1 full

More information

Conitel ASYNC Adapter

Conitel ASYNC Adapter Conitel ASYNC Adapter TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS... SECTION - INSTALLATION...6 SECTION - CONTROLS AND INDICATORS...9 SECTION - NETWORK MANAGEMENT PORT...11

More information

ISOLATED RS-232 TO RS-422/485 CONVERTER

ISOLATED RS-232 TO RS-422/485 CONVERTER QUICK START GUIDE ICD400A ISOLATED RS-232 TO RS-422/485 CONVERTER 24/7 TECHNICAL SUPPORT AT 877.877.2269 OR VISIT BLACKBOX.COM STEP 1 - Specifications Complies with FCC Class B and CE requirements. Withstands

More information

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix) USER S MANUAL PH232Ex1 Doc No: PH232Ex1-UM-001 #1 RS-232 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...

More information

Protocol/interface converter series

Protocol/interface converter series Protocol/interface converter series E1 to 10Base-T Protocol Converter 4E1 to 10/100Mbps Ethernet Protocol Converter 8E1 to 10/100Mbps Ethernet Protocol Converter E1 to V.35 Protocol Converter Protocol

More information

Enhanced Mini-Chansim Model VCS-232

Enhanced Mini-Chansim Model VCS-232 Enhanced Mini-Chansim Model VCS-232 Operations Manual ViaSat Inc. 6155 El Camino Real Carlsbad, CA 92009 http://www.viasat.com SAFETY WARNING Always observe standard safety precautions during installation,

More information

USER MANUAL. MODEL 1000P Non-Powered Short Haul Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

USER MANUAL. MODEL 1000P Non-Powered Short Haul Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301) USER MANUAL MODEL 1000P Non-Powered Short Haul Modem C E R T I F I E D An ISO-9001 Certified Company Part #07M1000PA Doc. #022031UA Revised 2/17/98 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007

More information

Data Sheet SRM-3A. Ultra-Miniature Isolated Short-Range Async Modem. The Access Company

Data Sheet SRM-3A. Ultra-Miniature Isolated Short-Range Async Modem. The Access Company Data Sheet SRM-3A Ultra-Miniature Isolated Short-Range Async Modem The Access Company Features Asynchronous transmission of up to 19.2 kbps Transmission range of up to 13 km (8 miles) Ultra-miniature modem

More information

TRP-C37M User s Manual

TRP-C37M User s Manual TRP-C37M User s Manual MODBUS TCP to RTU/ASCII Gateway Printed May. 2011 Rev 1.1 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191, Fax: 886-2-86781172

More information

Select a Data Communication Interface

Select a Data Communication Interface Printer Setup and Operation Select a Data Communication Interface Select a Data Communication Interface You may connect your print engine to a computer using one or more of the available connections. The

More information

USR-TCP Hard version: V2.0 File version: V

USR-TCP Hard version: V2.0 File version: V Serial Device Server - RS232/RS485 to Ethernet converter USR-TCP232-300 Hard version: V2.0 File version: V1.1 2011-8-17 Serial Device Server - RS232/RS485 to Ethernet converter is an Equipment for convert

More information

MESR Port Industrial Modbus Gateway. Specifications Power. MESR424_r000_2913ds

MESR Port Industrial Modbus Gateway. Specifications Power. MESR424_r000_2913ds MESR424 4-Port Industrial Modbus Gateway MESR424_r000_2913ds Ethernet-Enable Modbus RS-232/422/485 MODBUS TCP, ASCII & RTU Modbus Flexibility Serial & Ethernet, Masters & Slaves Modbus Messaging Priority

More information

Ethernet Serial Server

Ethernet Serial Server Ethernet Serial Server Users Manual Eport-101, Eport-102, Eport-104, Eport108 1 INTRODUCTION... 1 1.1 FEATURES... 1 1.2 PRODUCT SPECIFICATIONS... 2 1.3 DEFAULT SETTINGS... 3 2 COMMUNICATION MODES... 4

More information

Route 56.PCI Users Manual Part # 5101

Route 56.PCI Users Manual Part # 5101 Route 56.PCI Users Manual Part # 5101 Sealevel Systems, Inc. Telephone: 864.843.4343 155 Technology Place Fax: 864.843.3067 Liberty, SC 29657 USA www.sealevel.com Contents INTRODUCTION... 1 OVERVIEW...

More information

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual

Lantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual Lantech LSC-1102B SERIAL TO TCPIP CONVERTER User Manual V1.0 Sep 2016 Table of Contents 1. Introduction 3 Overview 4 Product Specifications 8 2. Description & Installation 10 Product Panel Views 10 LED

More information

Korenix JetCard Series Multiport Serial Card/Ethernet Switch Card User s Manual

Korenix JetCard Series Multiport Serial Card/Ethernet Switch Card User s Manual Korenix JetCard Series Multiport Serial Card/Ethernet Switch Card User s Manual Third Edition, Dec. 2008 www.korenix.com Korenix JetCard Series Multiport Serial Card/Ethernet Switch Card User s Manual

More information

ME500A BLACK BOX SPECIFICATIONS: BOTTOM OF UNIT INTRODUCTION: CONFIGURATION: Async Sync Industrial Line Driver PWR TX RX RTS CD. DB25 Female Conn.

ME500A BLACK BOX SPECIFICATIONS: BOTTOM OF UNIT INTRODUCTION: CONFIGURATION: Async Sync Industrial Line Driver PWR TX RX RTS CD. DB25 Female Conn. ME500A DB25 Female Conn. PWR TX RX BLACK BOX Async Sync Industrial Line Driver RTS CD PWR TX RX RTS CD ERROR TEST 511 511E Remote Normal Local ERROR TEST SPECIFICATIS: Transmission Format: Synchronous

More information

OPERATOR S MANUAL MODEL DSU-56SA. 56 Kbps Stand Alone CSU/DSU

OPERATOR S MANUAL MODEL DSU-56SA. 56 Kbps Stand Alone CSU/DSU MODEL DSU-56SA 56 Kbps Stand Alone CSU/DSU OPERATOR S MANUAL 280 I-80 West Exit 1 PO Box 1330 Verdi NV 89439 Tel: 775-345-8000 Fax: 775-345-8010 E-mail: support @sgdi.net DSU-56SA TABLE OF CONTENTS SECTION

More information

4xT1/E1 i nline probe ASE With LinkSafe capabilities

4xT1/E1 i nline probe ASE With LinkSafe capabilities Visual UpTime Select ASE model 807-0115 4xT1/E1 i nline probe ASE With LinkSafe capabilities Key features Four management ports MLPPP support on IP Transport software Inband management capability LinkSafe

More information

FCD-E1, FCD-T1 E1/T1 or Fractional E1/T1 Access Units

FCD-E1, FCD-T1 E1/T1 or Fractional E1/T1 Access Units FCD-E1, FCD-T1 Access units for E1/T1 or fractional E1/T1 services Several data ports with selectable sync data rates: n 56/64 kbps Optional sub-e1/t1 drop-and-insert port for PBX connectivity Fail-safe

More information

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface DESCRIPTION The modems are a series of general-purpose industrial modems, which can be used for data communication through Public Switched Telephone Networks (PSTN). The modems can operate in 2-wire, full-duplex,

More information

RS-232 Connector Pin Assignments

RS-232 Connector Pin Assignments APPENDIXB This appendix lists the connector pin assignments for the CDEs, and includes the following sections: Serial Console-Interface, page B- Ethernet, page B- Cable Pin Assignments, page B- Serial

More information

Installation Guide. 100BASE-TX/100BASE-FX Fast Ethernet Media Converter NC-200FT/FC. -1-iIiNC-200FT/FC P/N:

Installation Guide. 100BASE-TX/100BASE-FX Fast Ethernet Media Converter NC-200FT/FC. -1-iIiNC-200FT/FC P/N: Installation Guide 100BASE-TX/100BASE-FX Fast Ethernet Media Converter NC-200FT/FC -1-iIiNC-200FT/FC P/N:750-0166-001 Table le of Contents General Description...3 Specifications...4 Connectors & Cables...5

More information

HS-RN. 4-Channel Low Speed Data Module with End-to-End Signaling OPERATION MANUAL INSTALLATION AND

HS-RN. 4-Channel Low Speed Data Module with End-to-End Signaling OPERATION MANUAL INSTALLATION AND INSTALLATION AND OPERATION MANUAL HS-RN 4-Channel Low Speed Data Module with End-to-End Signaling Megaplex-2100/2104 Version 12, Megaplex-4100 Version 1.2 The Access Company HS-RN 4-Channel Low Speed

More information

USER MANUAL. MODEL 2011 High Speed Asynchronous to Synchronous Converter

USER MANUAL. MODEL 2011 High Speed Asynchronous to Synchronous Converter USER MANUAL MODEL 011 High Speed Asynchronous to Synchronous Converter Part# 07M011-A Doc# 0601UA Revised 03/16/94 SALES ICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com 1.0 WARRANTY

More information

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT

More information

MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual

MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual MGate TM EIP3000 DF1 to EtherNet/IP Gateway User s Manual First Edition, June 2009 www.moxa.com/product 2009 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. MGate EIP3000

More information

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual

RS-232/422/485 to Copper or Fiber. Ethernet Converter. User s Manual RS-232/422/485 to Copper or Fiber Ethernet Converter User s Manual Table Of Contents TABLE OF CONTENTS... 1 INTRODUCTION... 3 PRODUCT OVERVIEW... 3 PRODUCT FEATURES... 3 PACKING LIST... 4 LED INDICATORS...

More information

TRP-C41 User s Manual

TRP-C41 User s Manual TRP-C41 User s Manual Ethernet To Fiber Media Converter User s Manual Printed Oct. 2013 Rev 1.2 Trycom Technology Co.,Ltd No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. Tel : 886-3-350-3351

More information

Overview of the Cisco 2524 and Cisco 2525 Routers

Overview of the Cisco 2524 and Cisco 2525 Routers CHAPTER 1 Overview of the Cisco 2524 and Cisco 2525 Routers The Cisco 2524 and Cisco 2525 routers provide LAN and WAN access in a low-cost modular router platform that can grow with your internetworking

More information

IML 560 USER GUIDE. Low Power 56Kbps Industrial modem. Version 1.2. December 6, AYANTRA Inc.

IML 560 USER GUIDE. Low Power 56Kbps Industrial modem. Version 1.2. December 6, AYANTRA Inc. IML 560 USER GUIDE Low Power 56Kbps Industrial modem Version 1.2 December 6, 2002 AYANTRA Inc. Revision History Date Version Description By November 18, 2002 1.1 Initial Release - December 6, 2002 1.2

More information

ULTRA 485 USER MANUAL

ULTRA 485 USER MANUAL ULTRA 485 USER MANUAL Part #3055 Sealevel Systems, Inc. Telephone: (864) 843-4343 PO Box 830 Fax: (864) 843-3067 Liberty, SC 29657 USA www.sealevel.com Contents INTRODUCTION... 1 OVERVIEW...1 WHAT S INCLUDED...1

More information

TRP-C37 User s Manual

TRP-C37 User s Manual TRP-C37 User s Manual Ethernet to RS232/422/485 Converter Printed Oct. 2010 Rev 1.0 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191, Fax: 886-2-86781172

More information

F5-45x3/85x3 10/100Mbps Ethernet to 4E1/8E1 Converter User Manual

F5-45x3/85x3 10/100Mbps Ethernet to 4E1/8E1 Converter User Manual F5-45x3/85x3 10/100Mbps Ethernet to 4E1/8E1 Converter User Manual (Version 1.1) Beijing Fibridge Co., Ltd. Content 1. Overview... 3 2. Features... 4 2.1. Hardware... 4 2.2. Software... 5 3. Applications...

More information

PPP. Point-to-Point Protocol

PPP. Point-to-Point Protocol PPP Point-to-Point Protocol 1 Introduction One of the most common types of WAN connection is the point-to-point connection. Point-to-point connections are used to connect LANs to service provider WANs,

More information

FCD-E1E Managed E1 and Fractional E1 Access Device

FCD-E1E Managed E1 and Fractional E1 Access Device FCD-E1E E1 main link and sublink supporting both framed and unframed signals One data port with selectable sync data rates of n 64 kbps Optional sub-e1 drop-and-insert port Optional Ethernet 10/100BaseT

More information

STE100A Single Port IP to Serial Device Server

STE100A Single Port IP to Serial Device Server STE100A Single Port IP to Serial Device Server CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St., Neihu, Taipei 114, Taiwan T +886-2-26591021

More information

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units Data Sheet FCD-E1LC, FCD-T1LC Managed TDM multiplexers for access to full or fractional E1/T1 services Managed access units for E1/T1 or fractional E1/T1 service E1/T1 main link and sublink support framed

More information

Frame Relay Cabling This section describes the cabling and connector pinouts for the Frame Relay cards.

Frame Relay Cabling This section describes the cabling and connector pinouts for the Frame Relay cards. A P P E N D I X B Cabling Summary Introduction This appendix contains details on the MGX 8850 cabling. Note In all cable references, the transmit direction is away from the switch, and the receive direction

More information

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed Apr.2014 Rev 1.3

TRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed Apr.2014 Rev 1.3 TRP-C37 Ethernet to RS232/422/485 Converter User s Manual Printed Apr.2014 Rev 1.3 Trycom Technology Co.,Ltd No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. Tel : 886-3-350-3351 Fax:

More information

I-7560U/7561U/7563U. User Manual WARRANTY WARNING COPYRIGHT TRADEMARKS CONTACT US

I-7560U/7561U/7563U. User Manual WARRANTY WARNING COPYRIGHT TRADEMARKS CONTACT US I-7560U/7561U/7563U User Manual USB tto RS--232//422//485 Converrtterrss Verr.. 1..0,, Decc.. 2013 WARRANTY All products manufactured by ICP DAS are warranted against defective materials for a period of

More information

IM3523 IM3533 IM IM3536 LCR METER IM3570 IM7580 IM3590 CHEMICAL IMPEDANCE ANALYZER IMPEDANCE ANALYZER. Communication Instruction Manual

IM3523 IM3533 IM IM3536 LCR METER IM3570 IM7580 IM3590 CHEMICAL IMPEDANCE ANALYZER IMPEDANCE ANALYZER. Communication Instruction Manual Communication Instruction Manual IM3523 IM3533 IM3533-01 IM3536 LCR METER IM3570 IM7580 IMPEDANCE ANALYZER IM3590 CHEMICAL IMPEDANCE ANALYZER November 2014 Revised edition 6 IM3570A983-06 14-11H i Contents

More information

Industrial Isolated Converters

Industrial Isolated Converters ICD120A ICD140A Product Data Sheet Industrial Isolated Converters ICD120A Features Suitable for use in Class 1, Division 2, Groups A, B, C, and D Hazardous Locations, or Nonhazardous locations only. Easy

More information

LC1003A IP Security CCTV Connector Installation Guide

LC1003A IP Security CCTV Connector Installation Guide LC1003A IP Security CCTV Connector Installation Guide Responsibilities Black Box Corp. declines all liability for any damage that might result from any errors or omissions in this document or from improper

More information

LLM-336S.Eth. Introduction. Features. Industrial Leased line modem with internal Ethernet Bridge.

LLM-336S.Eth. Introduction. Features. Industrial Leased line modem with internal Ethernet Bridge. LLM-336.Eth Industrial Leased line modem with internal Ethernet Bridge. LLM-336D.Eth LLM-336S.Eth Introduction The MuLogic LLM-336.Eth is a voiceband modem combined with an Ethernet bridge for connecting

More information

Loop-O 9300 Fiber Optical Mux

Loop-O 9300 Fiber Optical Mux 300 Fiber Optical Mux U height unit U height unit 3U height unit Features Up to 6 E links on one fiber Support Quad RS3 to 6Kbps async (Optional) Support Quad V.35 (Optional) Support 0/00M Bridge (Optional)

More information

Chapter 2. Hardware Description. 2.1 Chassis. Note: For product specifications, see Appendix A, Specifications.

Chapter 2. Hardware Description. 2.1 Chassis. Note: For product specifications, see Appendix A, Specifications. Chapter 2 Hardware Description This chapter provides information on the hardware for the BANDIT product family. Note: For product specifications, see Appendix A, Specifications. 2.1 Chassis The chassis

More information

SyncLink USB Serial Adapter

SyncLink USB Serial Adapter SyncLink USB Serial Adapter Hardware User s Manual MicroGate Systems, Ltd http://www.microgate.com MicroGate and SyncLink are registered trademarks of MicroGate Systems, Ltd. Copyright 2012-2017 MicroGate

More information

The Wireless Connectivity Expert

The Wireless Connectivity Expert The Wireless Connectivity Expert 48511 Warm Springs Blvd., Suite 206, Fremont CA 94539 Tel: (510) 490-8024 Fax: (510) 623-7268 Website: http://www.actisys.com/ E-mail: irda-info@actisys.com ACT-IR100SD

More information

SyncLink GT Serial Adapter

SyncLink GT Serial Adapter SyncLink GT Serial Adapter Hardware User s Manual MicroGate Systems, Ltd http://www.microgate.com MicroGate and SyncLink are registered trademarks of MicroGate Systems, Ltd. Copyright 2008-2017 MicroGate

More information

E1/T1 Rate Converters

E1/T1 Rate Converters MT1100A MT1100C MT1101A-DC MT1102A-DC JULY 2003 MT1100A-DC MT1101A MT1102A MT1102C E1/T1 Rate Converters CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)

More information

Data Sheet and Installation

Data Sheet and Installation Data Sheet and Installation TinyBridge-100 Miniature Remote Fast Ethernet Bridge The Access Company Features High-performance miniature remote bridge for Fast Ethernet extension Wire-speed WAN throughput:

More information

RC905-EE1. Ethernet to E1 Interface Converter (REV.B) User Manual

RC905-EE1. Ethernet to E1 Interface Converter (REV.B) User Manual RC905-EE1 Ethernet to E1 Interface Converter (REV.B) User Manual 1 Contents Chapter 1 RC905-EE1(REV. B) Overview... 3 Chapter 2 Operating Instruction..... 4 Chapter 3 Connection..... 11 Chapter 4 Troubleshooting..

More information

Cabling Guide for Console and AUX

Cabling Guide for Console and AUX Page 1 of 13 Cabling Guide for and AUX Ports TAC Notice: What's Changing on TAC Web Help us help you. Contents Introduction Before You Begin Conventions Prerequisites Components Used Table of Routers with

More information

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT

More information