1 Application Description 03/2017 SCALANCE M, SCALANCE S, CP x43-1 Advanced, CP 1x43-1, TS Adapter IE Advanced, SINEMA Remote Connect

2 Siemens AG 2017 All rights reserved Table of Contents Warranty and Liability Note The Application Examples are not binding and do not claim to be complete regarding the circuits shown, equipping and any eventuality. The Application Examples do not represent customer-specific solutions. They are only intended to provide support for typical applications. You are responsible for ensuring that the described products are used correctly. These Application Examples do not relieve you of the responsibility to use safe practices in application, installation, operation and maintenance. When using these Application Examples, you recognize that we cannot be made liable for any damage/claims beyond the liability clause described. We reserve the right to make changes to these Application Examples at any time without prior notice. If there are any deviations between the recommendations provided in these Application Examples and other Siemens publications e.g. Catalogs the contents of the other documents have priority. We do not accept any liability for the information contained in this document. Any claims against us based on whatever legal reason resulting from the use of the examples, information, programs, engineering and performance data etc., described in this Application Example shall be excluded. Such an exclusion shall not apply in the case of mandatory liability, e.g. under the German Product Liability Act ( Produkthaftungsgesetz ), in case of intent, gross negligence, or injury of life, body or health, guarantee for the quality of a product, fraudulent concealment of a deficiency or breach of a condition which goes to the root of the contract ( wesentliche Vertragspflichten ). The damages for a breach of a substantial contractual obligation are, however, limited to the foreseeable damage, typical for the type of contract, except in the event of intent or gross negligence or injury to life, body or health. The above provisions do not imply a change of the burden of proof to your detriment. Any form of duplication or distribution of these Application Examples or excerpts hereof is prohibited without the expressed consent of the Siemens AG. Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement and continuously maintain a holistic, state-of-the-art industrial security concept. Siemens products and solutions only form one element of such a concept. Customer is responsible to prevent unauthorized access to its plants, systems, machines and networks. Systems, machines and components should only be connected to the enterprise network or the internet if and to the extent necessary and with appropriate security measures (e.g. use of firewalls and network segmentation) in place. Additionally, Siemens guidance on appropriate security measures should be taken into account. For more information about industrial security, please visit Siemens products and solutions undergo continuous development to make them more secure. Siemens strongly recommends to apply product updates as soon as available and to always use the latest product versions. Use of product versions that are no longer supported, and failure to apply latest updates may increase customer s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under Entry ID: , V2.1, 03/2017 Warranty and Liability

3 Siemens AG 2017 All rights reserved Table of Contents Table of Contents Warranty and Liability Remarks on this Document Purpose and objective Features and benefits Structure of this document Introduction into Remote Networks Remote networks & industrial security Security Integrated product portfolio SINEMA Remote Connect SCALANCE S612 and S62x SOFTNET Security Client SCALANCE M CP x43-1 Advanced CP 1x43-x CP TS Adapter IE Advanced LOGO! SCALANCE S VPN tunnel between SCALANCE S (VPN server) and SCALANCE S using a static IP address VPN tunnel between SCALANCE S (VPN server) and SCALANCE M81x-1 using a static IP address VPN tunnel between SCALANCE S (VPN server) and SOFTNET Security Client using a static IP address VPN tunnel between SCALANCE S (VPN server) and CP x43-1 Advanced using a static IP address VPN tunnel between SCALANCE S (VPN server) and SCALANCE M874-x using a static IP address VPN tunnel between SCALANCE S (VPN server) and a mobile client using a static IP address SCALANCE M-800/ S VPN tunnel between SCALANCE M81x-1 (VPN server) and SCALANCE M81x-1 using a static IP address VPN tunnel between SCALANCE S615 (VPN server) and SOFTNET Security Client using a static IP address VPN tunnel between SCALANCE M874-x (VPN server) and CP x43-1 Advanced using a static IP address VPN tunnel between SCALANCE M874-x (VPN server) and CP 1x43-1 using a static IP address VPN tunnel between SCALANCE M874-x (VPN server) and SCALANCE M874-x using a static IP address VPN tunnel between SCALANCE M874-x (VPN server) and a mobile client using a static IP address SINEMA Remote Connect VPN tunnel between SINEMA Remote Connect Server and a tablet (ios) VPN tunnel between SINEMA RC Server and a smartphone (Android) VPN tunnel between SCALANCE S615 and SINEMA RC client via the SINEMA RC server Entry ID: , V2.1, 03/2017 Warranty and Liability

4 Siemens AG 2017 All rights reserved Table of Contents 5.4 VPN tunnel between SCALANCE S615 and a tablet (ios) via the SINEMA RC server VPN tunnel between SCALANCE S615 and a smartphone (Android) via the SINEMA RC server VPN tunnel between two identical cells with S615 and SINEMA RC Client via the SINEMA RC Server by using the NAT function JumpHost application with SINEMA RC Server CP x43-1 Advanced VPN tunnel between CP x43-1 Advanced (VPN server) and SCALANCE S using a static IP address VPN tunnel between CP x43-1 Advanced (VPN server) and SCALANCE M81x-1 using a static IP address VPN tunnel between CP x43-1 Advanced (VPN server) and SOFTNET Security Client using a static IP address VPN tunnel between CP x43-1 Advanced (VPN server) and CP x43-1 Advanced using a static IP address VPN tunnel between CP x43-1 Advanced (VPN server) and SCALANCE M874-x using a static IP address VPN tunnel between CP x43-1 Advanced (VPN server) and a mobile client using a static IP address CP 1x43-x VPN tunnel between CP 1x43-1 (VPN server) and SCALANCE S using a static IP address VPN tunnel between CP 1x43-1 (VPN server) and SCALANCE M81x-1 using a static IP address VPN tunnel between CP 1x43-1 (VPN server) and SOFTNET Security Client using a static IP address VPN tunnel between CP 1x43-1 (VPN server) and CP x43-1 Advanced using a static IP address VPN tunnel between CP 1x43-1 (VPN server) and CP 1x43-1 using a static IP address VPN tunnel between CP 1x43-1 (VPN server) and SCALANCE M874-x using a static IP address VPN tunnel between CP 1x43-1 (VPN server) and a mobile client using a static IP address TS Adapter IE Advanced/ LOGO! VPN tunnel between TS Adapter IE Advanced (VPN server) and Windows SSTP client using a static IP address VPN tunnel between TS Adapter IE Advanced (VPN server) and TIA Portal using a static IP address VPN tunnel between LOGO! (VPN server) and a PC using a static IP address Links & Literature History Entry ID: , V2.1, 03/2017 Warranty and Liability

5 Siemens AG 2017 All rights reserved 1 Remarks on this Document 1.1 Purpose and objective 1 Remarks on this Document 1.1 Purpose and objective Purpose Objective Based on the Security Integrated product portfolio, there are numerous different ways of implementing a secure communication that are always customized to the application. For the user, looking for the perfect solution involves the following questions: Which solutions are available? What are the differences between the solutions? The Security Integrated portfolio includes several products that can be combined with each other. This results in a large number of configuration options. This document helps you find an optimal solution for secure communication based on VPN. 1.2 Features and benefits Properties Benefits The document has the following features: Clear, compact structure Concisely outlines the contents and provides an overview graphic of the individual configurations Does not describe details; the details are provided in the individual configurations. The document offers the following benefits to the reader: Support in planning and configuration Quick finding of information regarding configuration options Short, compact overview of the features Reference to the individual configurations Entry ID: , V2.1, 03/2017 Warranty and Liability

6 Siemens AG 2017 All rights reserved 1 Remarks on this Document 1.3 Structure of this document 1.3 Structure of this document Siemens' Security Integrated portfolio includes several products that can be combined with each other. This results in a large number of configuration options. To present these options in a clear manner, the possible configurations are classified based on specific criteria. This document gives you an overview of the configurations with the modules from the Remote Networks portfolio. Classification based on SIMATIC dependency The VPN solutions with the SCALANCE modules or TS Adapter are independent of SIMATIC, i.e. the application behind the VPN tunnel does not have to be a SIMATIC application. Access to other applications via the SCALANCE modules or TS Adapter is possible as well. The VPN solutions with the CPs are SIMATIC-based, since a SIMATIC CPU is required to operate the CP. However, these configurations also allow access to non-simatic plant components via the CP. Classification of the configurations The possible configurations of an IP-based remote network are divided into groups. The criterion for this subdivision is the module that acts as the VPN server. There is a separate group for each module that can be configured as a VPN server. This results in the following subdivision of VPN server groups: SCALANCE S SCALANCE M874 SCALANCE M810 SINEMA Remote Connect CP x43-1 Adv. CP 1x43-1 CP 1628 TS Adapter IE Advanced LOGO! CMR Note For configuration examples for the CP 1628, use the following link: \10. Contents of a group A group can in turn consist of multiple configurations. All these configurations have one thing in common: for all configurations, the VPN server is the same security module - specified by the group. They differ in the module used as the VPN client. For all possible configurations of a group, Siemens Industry Online Support provides a document with a specific configuration guide for the settings of the VPN modules. The figure below shows the subdivision of the configurations. Entry ID: , V2.1, 03/2017 Warranty and Liability

7 Siemens AG 2017 All rights reserved 1 Remarks on this Document 1.3 Structure of this document Figure 1-1 Oerview doc Remote Access (IP based) Group VPN server VPN server VPN server VPN server VPN server VPN server SCALANCE S SCALANCE M-800 SCALANCE S615 SINEMA Remote Connect CP x43-1 Adv. CP 1x43-x TS- Adapter LOGO! CMR Configurati on Configurations that belong to the same group have the same color (e.g., yellow for the SCALANCE S group). In the relevant chapter, each configuration is presented homogeneously in an overview graphic, including a list of requirements and the link for the detailed configuration description. Entry ID: , V2.1, 03/2017 Warranty and Liability

8 Siemens AG 2017 All rights reserved 2 Introduction into Remote Networks 2.1 Remote networks & industrial security 2 Introduction into Remote Networks 2.1 Remote networks & industrial security Remote networks Remote networks are public or private communications infrastructures for covering wide areas or long distances, for example mobile or fixed telephone networks. The geographical distribution of automation cells increases the demand for telecontrol (remote control) and teleservice (remote maintenance/diagnostics) in a remote network. The comprehensive Remote Networks portfolio from Siemens offers connection to both conventional (dedicated line, telephone) and IP-based infrastructures (e.g., the ). Applications Possible remote access applications in a remote network: Telecontrol Connection of outstations (remote terminal units - RTUs) distributed over a wide geographical area to one or more central control systems for the purpose of operator control and monitoring. Teleservice Data exchange with distant technical systems such as machines, plants and computers for the purpose of error detection, diagnostics, maintenance, repair and optimization. Integration into the industrial security concept This document focuses on IP-based networks. Since remote access to the plant is implemented via a public network (e.g., the ), protection against data manipulation and spying is particularly important. For this purpose, virtual private networks (VPN) are used. VPN A VPN is a private network that uses a public network (e.g., the ) as a transit network for transmitting data to a private destination network. The private networks and the transit network need not be compatible with one another. Although VPN uses the addressing mechanisms of the transit network, it nevertheless uses its own network packets to separate the transport of private data packets from the others. Due to this fact, the private networks appear as a shared, logical (virtual) network. VPN routers are required to set up a VPN. The VPN Security Integrated products (VPN routers) by Siemens (SCALANCE S/M and CPs) support IPsec (IP Security) protocol. SINEMA Remote Connect as VPN server enables VPN connections via OpenVPN and IPsec. LOGO! CMR support the VPN server function with pre-shared key. SCALANCE S615 supports the IPsec protocol, however, it can also be used as OpenVPN client. The TS Adapter IE Advanced uses Microsoft's SSTP (Secure Socket Tunneling Protocol). Entry ID: , V2.1, 03/2017 Warranty and Liability

9 Siemens AG 2017 All rights reserved 2 Introduction into Remote Networks 2.1 Remote networks & industrial security VPN client and VPN server The nodes of a secured data communication via VPN take on different roles: VPN server VPN client The tunnel endpoint that actively starts the VPN connecting process is referred to as VPN client. The remote end that waits for the VPN client is called the VPN server. Note For more information on the Siemens Security Concept, use the following link: \3\. Entry ID: , V2.1, 03/2017 Warranty and Liability

10 Siemens AG 2017 All rights reserved 2 Introduction into Remote Networks 2.2 Security Integrated product portfolio 2.2 Security Integrated product portfolio Through a combination of different security measures such as firewalls and VPN, the security modules protect individual devices or even entire automation cells against: Data espionage Data manipulation Unwanted access The figure below shows the remote access cells. Figure 2-1 Service PCs SSC SINEMA RC SCALANCE M874-x Smartphone with IPSec Client App SCALANCE S Windows SSTP SCALANCE M81x-1 Automation Cells SCALANCE S SIMATIC S7 Stations SCALANCE M874-x SIMATIC S7-300 or S7-400 with CP x43-1 Advanced SIMATIC S or S with CP 1x43-1 TS Adapter IE Advanced SIMATIC S7 Stations SCALANCE M81x-1 SIMATIC S7 Stations SIMATIC S7 Stations To help you select products, the following sections describe the most important features of the respective security modules. Entry ID: , V2.1, 03/2017 Warranty and Liability

11 Siemens AG 2017 All rights reserved 2 Introduction into Remote Networks 2.2 Security Integrated product portfolio SINEMA Remote Connect SINEMA Remote Connect is a management platform for remote networks that centrally manages secure tunnel connections. Distributed plants or machines can be conveniently and safely serviced via remote access. Even if the machines are integrated in third-party networks; for example, in the plants at the end customers of machine constructors. Components of a solution with SINEMA Remote Connect: SINEMA Remote Connect as VPN server Endgeräte (VPN client): SCALANCE S615 (with KEY-PLUG) SCALANCE S612, S623, S627 SCALANCE M-800 (with KEY-PLUG) SINEMA Remote Connect Client SOFTNET Security Client OpenVPN client SINEMA Remote Connect Server SINEMA Remote Connect Server is a server application and provides an integrated connection management of distributed networks via the internet. It coordinates the secure connecting process between users, distributed plants, and machines. The following functions are handled by the SINEMA Remote Connect server: Management and establishing of encrypted connections with OpenVPN. Verification via CA certificate or finger print. User management with the configuration of privileges. Establishing permanent or event-based connections (connecting via wake up SMS or via a signal at the digital input). Supporting routing and NAT for connecting subnets behind SCALANCE S615. Provision of secure remote access to subordinate networks for servicing, control and diagnostic purposes. Web Based Management (WBM) for configuring the server. Entry ID: , V2.1, 03/2017 Warranty and Liability

12 Siemens AG 2017 All rights reserved 2 Introduction into Remote Networks 2.2 Security Integrated product portfolio SCALANCE S615 SCALANCE S615 is a Security module for securing devices, automation cells, or network segments in Ethernet networks against external and internal dangers. It provides the same functionality and features as the previous SCALANCE M variants. In addition, there are some specific LAN functions which enable optimized connection with SINEMA Remote Connect. Amongst others, SCALANCE S615 is distinguished by the following characteristics: Support of VPN for secure authentication of network nodes, for data encryption and verifying data integrity. IPsec VPN tunnel (server and client functionality) OpenVPN for connecting to SINEMA Remote Connect (client function) High-quality stateful inspection firewall with filtering of IP-based data traffic and communication protocols. Support of NAT/NAPT; also in connection with IPsec and OpenVPN. Supporting VLAN. Flexible, reaction-free and protocol-independent protection. Support of multiple VPN tunnels at a time. Simplest connection to SINEMA Remote Connect via Auto configuration interface (can be enabled via KEY-PLUG SINEMA REMOTE CONNECT). SINEMA Remote Connect Client SINEMA Remote Connect Client is an Open software for optimal connection of programming devices, PCs and notebooks to the SINEMA Remote Connect server. It is characterized by the following features: Support of VPN (OpenVPN) for secure authentication of network nodes, for data encryption and verifying data integrity. Simplest connection to SINEMA Remote Connect via auto configuration interface. Address book with all devices assigned to a user. Proxy server for communication with networks behind a proxy server infrastructure. Support of HTTPS and SOCKS Proxy Server. Selecting a device for performing teleservice within the SIMATIC environment. Entry ID: , V2.1, 03/2017 Warranty and Liability

13 Siemens AG 2017 All rights reserved 2 Introduction into Remote Networks 2.2 Security Integrated product portfolio SCALANCE S612 and S62x The security modules of the SCALANCE S family are designed specifically for use in automation but integrate seamlessly with the security structures of the office and IT world. The SCALANCE S612, SCALANCE S623 and SCALANCE S627-2M modules additionally provide the following features: Simultaneous protection of multiple devices by IPsec tunnels (support of up to 128 VPN tunnels at a time). IP addresses are automatically obtained from the internet service provider using PPPoE; therefore, it is no longer necessary to use a separate DSL router; a DSL modem can be used instead. Use of DNS for VPN tunnels using public dynamic IP addresses from the service provider. User-specific IP firewall to distinguish and differentiate access to specific plant parts. Note For the technical specifications of the SCALANCE S modules, use the following link: \4\ SOFTNET Security Client The SOFTNET Security Client allows programming devices, PCs and notebook computers access to network nodes or automation systems protected by SCALANCE S, SCALANCE M or CPs. It is characterized by the following features: Secure access of programming devices or notebook computers to entire automation cells. Easy use on mobile PCs. Non-secure devices can be integrated into the secure data traffic. Supports the DNS client function SCALANCE M-800 SCALANCE M874 The SCALANCE M874-3 (HSPA+ router) and SCALANCE M874-2 (GPRS/EDGE router) routers are suited for cellular networks. These modules are characterized by the following features: Simultaneous protection of multiple devices by IPsec tunnels (support of up to 10 VPN tunnels at a time). Broad range of applications; can be used wherever a GPRS/UMTS network is available. Connection of stationary stations and/or mobile stations. Simplicity of connecting local networks by means of IP communication via WAN. User-specific IP firewall to distinguish and differentiate access to specific plant parts. Entry ID: , V2.1, 03/2017 Warranty and Liability

14 Siemens AG 2017 All rights reserved 2 Introduction into Remote Networks 2.2 Security Integrated product portfolio Note For the technical specifications of the SCALANCE M874 modules, use the following link: \5\. SCALANCE M81x-1 SCALANCE M812-1 and SCALANCE M816-1 are DSL routers for cost-effective, secure connection of Ethernet-based subnets and programmable controllers to wired telephone or DSL networks. They support ADSL2+ (Asynchronous Digital Subscriber Line). These modules are characterized by the following features: Simultaneous protection of multiple devices by IPsec tunnels (support of up to 20 VPN tunnels at a time). VPN and DSL router in a single device; therefore, it is no longer necessary to use a separate DSL router. Broad range of applications due to high bandwidth, performance and speed. Reduced travel expenses and personnel costs due to remote programming and remote diagnostics via wired telephone or DSL networks. User-specific IP firewall to distinguish and differentiate access to specific plant parts. Note For the technical specifications of the SCALANCE M810 modules, use the following link: \6\. Entry ID: , V2.1, 03/2017 Warranty and Liability

15 Siemens AG 2017 All rights reserved 2 Introduction into Remote Networks 2.2 Security Integrated product portfolio CP x43-1 Advanced CP Advanced and CP Advanced are communications processors for connecting SIMATIC S7-CPUs to PROFINET / networks. For the SIMATIC S7-300/S7-400, they are the bridge between the field level and the MES level and integrate seamlessly with the security structures of the office and IT world. These modules are characterized by the following features: Firewall, VPN gateway and communications processor in a single device Protection of S7-300/S7-400 controllers and their lower-level networks by IPsec tunnels (support of up to 32 VPN tunnels at a time). Note For the technical specifications of CP Advanced, use the following link: \7\. Note For the technical specifications of CP Advanced, use the following link: \8\ CP 1x43-x The CP 1243-x communication processor securely connects the SIMATIC S controller to Ethernet networks. The CP communication processor securely connects the SIMATIC S controller to Ethernet networks. These modules are characterized by the following features: Firewall, VPN gateway and communications processor in a single device Protection of S7-1200/S controllers and their lower-level networks by IPsec tunnels (support of up to 16 VPN tunnels at a time). Note For the technical specifications of the CP 1243-x, use the following link: \13\ Note For the technical specifications of CP , use the following link: \14\. Entry ID: , V2.1, 03/2017 Warranty and Liability

16 Siemens AG 2017 All rights reserved 2 Introduction into Remote Networks 2.2 Security Integrated product portfolio CP 1628 CP 1628 is a communications module for securely connecting a PG/PC to. With a dedicated processor for automation/security tasks, the CP 1628 reduces the host PC's load and provides constant, stable and secure data communication. This module is characterized by the following features: Firewall, VPN gateway and communications processor in a single device. Simultaneous protection of multiple devices by IPsec tunnels (support of up to 64 VPN tunnels at a time). Note For the technical specifications of CP 1628, use the following link: \9\ TS Adapter IE Advanced In conjunction with TIA Portal (V12 SP1 or higher), the TS Adapter IE Advanced allows access, through the, to all automation components of a plant (e.g., S7 controllers) that are connected to. This module is characterized by the following features: Aside from TIA Portal, no other software or hardware is required to establish the VPN connection (VPN client). 1 Protection of S7 controllers and their lower-level networks by SSTP. Note For the technical specifications of TS Adapter IE Advanced, use the following link: \ LOGO! LOGO! Siemens is an intelligent logic module and ideally suitable for the realization of simple automation tasks in industry and building technology. The use of expansion modules enables LOGO! to control even complex plants without any problems. Using LOGO! CMR in combination with the LOGO! 8 basic modules (BM) makes it possible for you to monitor and control distributed plants and systems via text messages. You can remotely access the web interface of LOGO! CMR and LOGO! BM via mobile wireless network. The remote access makes it possible, for example, to install the LOGO! BM program remotely. Note For the technical specifications of LOGO! use the following link: \16. 1 access and a DSL modem are required to access the. Entry ID: , V2.1, 03/2017 Warranty and Liability

17 Siemens AG 2017 All rights reserved 3 SCALANCE S 3 SCALANCE S This chapter describes the configurations in which the SCALANCE S is configured as the VPN server. This group is marked in yellow. Table 3-1 SCALANCE S VPN remote end IP address Characteristics The SCALANCE S can be located either behind a DSL router or a DSL modem. A static or dynamic public IP address can be used for the DSL router/modem on the VPN server side. Up to 128 VPN tunnels can be established simultaneously; therefore, multiple secure connections can run simultaneously and independently of one another. A service employee or system on the VPN client side can establish the VPN tunnel only when necessary; a permanent tunnel connection is not necessary. By selecting the routing function, the networks at the internal and external interface become separate subnets. Entry ID: , V2.1, 03/

18 Siemens AG 2017 All rights reserved 3 SCALANCE S 3.1 VPN tunnel between SCALANCE S (VPN server) and SCALANCE S using a static IP address 3.1 VPN tunnel between SCALANCE S (VPN server) and SCALANCE S using a static IP address Figure 3-1 Service PC Automation Cell SCALANCE S SCALANCE S Modem/ VPN Tunnel SIMATIC S7 Stations Table 3-2 SCALANCE S SCALANCE S IP address public IP address for the router of the VPN server router with port forwarding functionality (on the VPN server side) Standard modem, router or UMTS router, for example SCALANCE M873 (on the VPN client side) Link to the configuration description: Entry ID: , V2.1, 03/

19 Siemens AG 2017 All rights reserved 3 SCALANCE S 3.2 VPN tunnel between SCALANCE S (VPN server) and SCALANCE M81x-1 using a static IP address 3.2 VPN tunnel between SCALANCE S (VPN server) and SCALANCE M81x-1 using a static IP address Figure 3-2 Service PC SCALANCE S SCALANCE M81x-1 Automation Cell VPN Tunnel SIMATIC S7 Stations Table 3-3 SCALANCE S SCALANCE M81x-1 IP address public IP address for the router of the VPN server. router with port forwarding functionality (on the VPN server side). Link to the configuration description: Entry ID: , V2.1, 03/

20 Siemens AG 2017 All rights reserved 3 SCALANCE S 3.3 VPN tunnel between SCALANCE S (VPN server) and SOFTNET Security Client using a static IP address 3.3 VPN tunnel between SCALANCE S (VPN server) and SOFTNET Security Client using a static IP address Figure 3-3 Service PC with SOFTNET Security Client SSC Modem/ SCALANCE S Automation Cell VPN Tunnel SIMATIC S7 Stations Table 3-4 SCALANCE S SOFTNET Security Client IP address public IP address for the router of the VPN server. router with port forwarding functionality (on the VPN server side). Standard modem, router or UMTS router, for example SCALANCE M873 (on the VPN client side). Link to the configuration description: Entry ID: , V2.1, 03/

21 Siemens AG 2017 All rights reserved 3 SCALANCE S 3.4 VPN tunnel between SCALANCE S (VPN server) and CP x43-1 Advanced using a static IP address 3.4 VPN tunnel between SCALANCE S (VPN server) and CP x43-1 Advanced using a static IP address Figure 3-4 Service PC Automation Cell SCALANCE S Modem/ SIMATIC S7-300 or S7-400 with CP x43-1 Advanced VPN Tunnel Table 3-5 SCALANCE S CP x43-1 Advanced IP address public IP address for the router of the VPN server. router with port forwarding functionality (on the VPN server side). Standard modem, router or UMTS router, for example SCALANCE M873 (on the VPN client side). Link to the configuration description: Entry ID: , V2.1, 03/

22 Siemens AG 2017 All rights reserved 3 SCALANCE S 3.5 VPN tunnel between SCALANCE S (VPN server) and SCALANCE M874-x using a static IP address 3.5 VPN tunnel between SCALANCE S (VPN server) and SCALANCE M874-x using a static IP address Figure 3-5 Service PC SCALANCE S SCALANCE M874-x Automation Cell VPN Tunnel SIMATIC S7 Stations Table 3-6 SCALANCE S SCALANCE M874-x IP address public IP address for the router of the VPN server. router with port forwarding functionality (on the VPN server side). Mobile network operator's default APN (on the VPN client side). Link to the configuration description: Entry ID: , V2.1, 03/

23 Siemens AG 2017 All rights reserved 3 SCALANCE S 3.6 VPN tunnel between SCALANCE S (VPN server) and a mobile client using a static IP address 3.6 VPN tunnel between SCALANCE S (VPN server) and a mobile client using a static IP address Figure 3-6 Smartphone with IPSec Client App SCALANCE S Automation Cell VPN Tunnel SIMATIC S7 Stations Table 3-7 SCALANCE S Mobile client IP address public IP address for the router of the VPN server. router with port forwarding functionality (on the VPN server side). Mobile network operator's default APN (on the VPN client side). Smartphone with IPSec Client app and Android operating system (on the VPN client side). Link to the configuration description: Entry ID: , V2.1, 03/

24 Siemens AG 2017 All rights reserved 4 SCALANCE M-800/ S615 4 SCALANCE M-800/ S615 This chapter describes the configurations in which the SCALANCE M-800/ S615 is configured as the VPN server. This group is marked in light red. Table 4-1 SCALANCE M-800, SCALANCE S615 VPN remote end IP address Characteristics The plant with the SCALANCE M-800/ S615 as the VPN server can be both stationary and mobile. A static or dynamic public IP address can be used for the SCALANCE M-800/ S615. Several VPN tunnels can be established in parallel; therefore, multiple secure connections can run simultaneously and independent of one another. A service employee or system on the VPN client side can establish the VPN tunnel only when necessary; a permanent tunnel connection is not necessary. Entry ID: , V2.1, 03/

25 Siemens AG 2017 All rights reserved 4 SCALANCE M-800/ S VPN tunnel between SCALANCE M81x-1 (VPN server) and SCALANCE M81x-1 using a static IP address 4.1 VPN tunnel between SCALANCE M81x-1 (VPN server) and SCALANCE M81x-1 using a static IP address Figure 4-1 Service PC SCALANCE M81x-1 SCALANCE M81x-1 Automation Cell VPN Tunnel SIMATIC S7 Stations Table 4-2 SCALANCE M81x-1 SCALANCE M81x-1 IP address public IP address for the VPN server. Link to the configuration description: Entry ID: , V2.1, 03/

26 Siemens AG 2017 All rights reserved 4 SCALANCE M-800/ S VPN tunnel between SCALANCE S615 (VPN server) and SOFTNET Security Client using a static IP address 4.2 VPN tunnel between SCALANCE S615 (VPN server) and SOFTNET Security Client using a static IP address Figure 4-2 Service PC with SOFTNET Security Client SSC Modem/ S615 Automation Cell VPN Tunnel SIMATIC S7 Stations Table 4-3 SCALANCE S615 SOFTNET Security Client IP address public IP address from the mobile network operator that can also be accessed from the (on the VPN server side). Standard modem, router or UMTS router, for example SCALANCE M873 (on the VPN client side). Link to the configuration description: Entry ID: , V2.1, 03/

27 Siemens AG 2017 All rights reserved 4 SCALANCE M-800/ S VPN tunnel between SCALANCE M874-x (VPN server) and CP x43-1 Advanced using a static IP address 4.3 VPN tunnel between SCALANCE M874-x (VPN server) and CP x43-1 Advanced using a static IP address Figure 4-3 Service PC SCALANCE M874-x Modem/ Automation Cell SIMATIC S7-300 or S7-400 with CP x43-1 Advanced VPN Tunnel Table 4-4 SCALANCE M874-x CP x43-1 Advanced IP address public IP address from the mobile network operator that can also be accessed from the (on the VPN server side). Mobile network operator's default APN (on the VPN server side). Standard modem, router or UMTS router, for example SCALANCE M873 (on the VPN client side). Entry ID: , V2.1, 03/

28 Siemens AG 2017 All rights reserved 4 SCALANCE M-800/ S VPN tunnel between SCALANCE M874-x (VPN server) and CP 1x43-1 using a static IP address 4.4 VPN tunnel between SCALANCE M874-x (VPN server) and CP 1x43-1 using a static IP address Figure 4-4 Service PC SCALANCE M874-x Modem/ Automation Cell SIMATIC S or S with CP 1x43-1 VPN Tunnel Table 4-5 SCALANCE M874-x CP 1x43-1 IP address public IP address from the mobile network operator that can also be accessed from the (on the VPN server side). Mobile network operator's default APN (on the VPN server side). Standard modem, router or UMTS router, for example SCALANCE M873 (on the VPN client side). Link to the configuration description: In progress Entry ID: , V2.1, 03/

29 Siemens AG 2017 All rights reserved 4 SCALANCE M-800/ S VPN tunnel between SCALANCE M874-x (VPN server) and SCALANCE M874-x using a static IP address 4.5 VPN tunnel between SCALANCE M874-x (VPN server) and SCALANCE M874-x using a static IP address Figure 4-5 Service PC SCALANCE M874-x SCALANCE M874-x Automation Cell VPN Tunnel SIMATIC S7 Stations Table 4-6 SCALANCE M874-x SCALANCE M874-x IP address public IP address from the mobile network operator that can also be accessed from the (on the VPN server side). Mobile to mobile communication (depending on the mobile network operator). Entry ID: , V2.1, 03/

30 Siemens AG 2017 All rights reserved 4 SCALANCE M-800/ S VPN tunnel between SCALANCE M874-x (VPN server) and a mobile client using a static IP address 4.6 VPN tunnel between SCALANCE M874-x (VPN server) and a mobile client using a static IP address Figure 4-6 Smartphone with IPSec Client App SCALANCE M874-x Automation Cell VPN Tunnel WAN IP Adress SIMATIC S7 Stations Table 4-7 SCALANCE M874-x Mobile client IP address public IP address from the mobile network operator that can also be accessed from the (on the VPN server side). Mobile to mobile communication (depending on the mobile network operator). Smartphone with IPSec Client app and Android operating system (on the VPN client side). Entry ID: , V2.1, 03/

31 Siemens AG 2017 All rights reserved 5 SINEMA Remote Connect 5 SINEMA Remote Connect This chapter describes the configurations in which the SINEMA Remote Connect is configured as the VPN server. This group is marked in light blue color. Table 5-1 SINEMA Remote Connect VPN remote end IP address Characteristics The VPN client can either be a PC with SINEMA Remote Connect Client or a smartphone/tablet with an OpenVPN-Client app. A service employee or system on the VPN client side can establish the VPN tunnel only when necessary; a permanent tunnel connection is not necessary. Entry ID: , V2.1, 03/

32 Siemens AG 2017 All rights reserved 5 SINEMA Remote Connect 5.1 VPN tunnel between SINEMA Remote Connect Server and a tablet (ios) 5.1 VPN tunnel between SINEMA Remote Connect Server and a tablet (ios) Figure 5-1 Central Station Service technician with mobile end device SINEMA Remote Connect Server WAN VPN Tunnel Table 5-2 SINEMA Remote Connect Tablet (ios) with Open app IP address public IP address for the router of the VPN server. router with port forwarding functionality (on the VPN server side). Tablet with Open app and ios operating system (VPN client side). Standard internet router with WLAN functionality (VPN client side). Link to the configuration description: Entry ID: , V2.1, 03/

33 Siemens AG 2017 All rights reserved 5 SINEMA Remote Connect 5.2 VPN tunnel between SINEMA RC Server and a smartphone (Android) 5.2 VPN tunnel between SINEMA RC Server and a smartphone (Android) Figure 5-2 Central Station SINEMA Remote Connect Server VPN Tunnel WAN Service technician with mobile end device Table 5-3 SINEMA Remote Connect Smartphone (Android) with Open app IP address public IP address for the router of the VPN server. router with port forwarding functionality (on the VPN server side). Mobile network operator's default APN (on the VPN client side). Smartphone with Open app and Android operating system (VPN client side). Link to the configuration description: Entry ID: , V2.1, 03/

34 Siemens AG 2017 All rights reserved 5 SINEMA Remote Connect 5.3 VPN tunnel between SCALANCE S615 and SINEMA RC client via the SINEMA RC server 5.3 VPN tunnel between SCALANCE S615 and SINEMA RC client via the SINEMA RC server Figure 5-3 SINEMA Remote Connect Server Central Station S615 Automation Cell WAN Service Technician VPN Tunnel Table 5-4 VPN server VPN clients Access type SINEMA Remote Connect SCALANCE S615, SINEMA Remote Connect client IP address public IP address for the router of the VPN server. router with port forwarding functionality (on the VPN server side). Standard modem, router or UMTS router, for example SCALANCE M873 (on the VPN client side). Link to the configuration description: Entry ID: , V2.1, 03/

35 Siemens AG 2017 All rights reserved 5 SINEMA Remote Connect 5.4 VPN tunnel between SCALANCE S615 and a tablet (ios) via the SINEMA RC server 5.4 VPN tunnel between SCALANCE S615 and a tablet (ios) via the SINEMA RC server Figure 5-4 Central Station SINEMA Remote Connect Server S615 Automation Cell Statische WAN Service Technician VPN Tunnel Table 5-5 VPN server VPN clients Access type SINEMA Remote Connect SCALANCE S615, tablet (ios) with Open app IP address public IP address for the router of the VPN server. router with port forwarding functionality (on the VPN server side). Standard modem, router or UMTS router, for example SCALANCE M873 (on the VPN client side). Tablet with Open app and ios operating system (VPN client side). Link to the configuration description: Entry ID: , V2.1, 03/

36 Siemens AG 2017 All rights reserved 5 SINEMA Remote Connect 5.5 VPN tunnel between SCALANCE S615 and a smartphone (Android) via the SINEMA RC server 5.5 VPN tunnel between SCALANCE S615 and a smartphone (Android) via the SINEMA RC server Figure 5-5 Central Station SINEMA Remote Connect Server WAN Service Technician S615 Automation Cell VPN Tunnel Table 5-6 VPN server VPN clients Access type SINEMA Remote Connect SCALANCE S615, smartphone (Android) with Open app IP address public IP address for the router of the VPN server. router with port forwarding functionality (on the VPN server side). Mobile network operator's default APN (on the VPN client side). Smartphone with Open app and Android operating system (VPN client side). Link to the configuration description: Entry ID: , V2.1, 03/

37 Siemens AG 2017 All rights reserved 5 SINEMA Remote Connect 5.6 VPN tunnel between two identical cells with S615 and SINEMA RC Client via the SINEMA RC Server by using the NAT function Figure 5-6 Service VPN client S615 Cell 1 WAN Central SINEMA Remote Connect Server VPN client VPN server S615 Cell 2 VPN tunnel VPN client Entry ID: , V2.1, 03/

38 Siemens AG 2017 All rights reserved 5 SINEMA Remote Connect Table 5-7 VPN server VPN clients Access type SINEMA Remote Connect SCALANCE S615, SINEMA Remote Connect client IP address public IP address and port forwarding for the router of the VPN server. Identical IP subnet in the automation cells Link to the configuration description: Entry ID: , V2.1, 03/

39 Siemens AG 2017 All rights reserved 5 SINEMA Remote Connect 5.7 JumpHost application with SINEMA RC Server Übersicht Figure 5-7 Service technician VPN client WAN Data center/ DMZ SINEMA RC Server JumpHost Virtual Desktop S615 Cell network VPN server VPN client VPN Tunnel enterprise network VPN client Entry ID: , V2.1, 03/

40 Siemens AG 2017 All rights reserved 5 SINEMA Remote Connect Table 5-8 VPN-Server VPN-Clients Zugriffsart SINEMA Remote Connect SCALANCE S615, SINEMA Remote Connect-Client IP address Voraussetzungen public IP address and port forwarding for the router of the VPN server. DMZ with SINEMA Remote Connect Server and JumpHost Virtual Desktop Link to the configuration description: Entry ID: , V2.1, 03/

41 Siemens AG 2017 All rights reserved 6 CP x43-1 Advanced 6 CP x43-1 Advanced This chapter describes the configurations in which the CP x43-1 Advanced is configured as the VPN server. This group is marked in dark blue. Table 6-1 CP x43-1 Advanced VPN remote end IP address Characteristics The firewall, VPN server and communication settings are made directly in the CP x43-1 Advanced; the security functions are integrated in the communications processor. A static or dynamic public IP address can be used for the DSL router on the VPN server side. Entry ID: , V2.1, 03/

42 Siemens AG 2017 All rights reserved 6 CP x43-1 Advanced 6.1 VPN tunnel between CP x43-1 Advanced (VPN server) and SCALANCE S using a static IP address 6.1 VPN tunnel between CP x43-1 Advanced (VPN server) and SCALANCE S using a static IP address Figure 6-1 Service PC Automation Cell SCALANCE S Modem/ SIMATIC S or S with CP 1x43-1 VPN Tunnel Table 6-2 CP x43-1 Advanced SCALANCE S IP address public IP address for the router of the VPN server. router with port forwarding functionality (on the VPN server side). Standard modem, router or UMTS router, for example SCALANCE M873 (on the VPN client side). Link to the configuration description: Entry ID: , V2.1, 03/

43 Siemens AG 2017 All rights reserved 6 CP x43-1 Advanced 6.2 VPN tunnel between CP x43-1 Advanced (VPN server) and SCALANCE M81x-1 using a static IP address 6.2 VPN tunnel between CP x43-1 Advanced (VPN server) and SCALANCE M81x-1 using a static IP address Figure 6-2 Service PC SCALANCE M81x-1 Automation Cell SIMATIC S or S with CP 1x43-1 VPN Tunnel Table 6-3 CP x43-1 Advanced SCALANCE M874-x IP address public IP address for the router of the VPN server. router with port forwarding functionality (on the VPN server side). Link to the configuration description: Entry ID: , V2.1, 03/

44 Siemens AG 2017 All rights reserved 6 CP x43-1 Advanced 6.3 VPN tunnel between CP x43-1 Advanced (VPN server) and SOFTNET Security Client using a static IP address 6.3 VPN tunnel between CP x43-1 Advanced (VPN server) and SOFTNET Security Client using a static IP address Figure 6-3 Service PC with SOFTNET Security Client SSC Modem/ Automation Cell SIMATIC S or S with CP 1x43-1 VPN Tunnel Table 6-4 CP x43-1 Advanced SOFTNET Security Client IP address public IP address for the router of the VPN server. router with port forwarding functionality (on the VPN server side). Standard modem, router or UMTS router, for example SCALANCE M873 (on the VPN client side). Link to the configuration description: Entry ID: , V2.1, 03/

45 Siemens AG 2017 All rights reserved 6 CP x43-1 Advanced 6.4 VPN tunnel between CP x43-1 Advanced (VPN server) and CP x43-1 Advanced using a static IP address 6.4 VPN tunnel between CP x43-1 Advanced (VPN server) and CP x43-1 Advanced using a static IP address Figure 6-4 Automation Cell A Automation Cell B SIMATIC S7-300 or S7-400 mit CP x43-1 Advanced Modem/ SIMATIC S7-300 or S7-400 with CP x43-1 Advanced VPN tunnel Table 6-5 CP x43-1 Advanced CP x43-1 Advanced IP address public IP address for the router of the VPN server. router with port forwarding functionality (on the VPN server side). Standard modem, router or UMTS router, for example SCALANCE M873 (on the VPN client side). Link to the configuration description: Entry ID: , V2.1, 03/

46 Siemens AG 2017 All rights reserved 6 CP x43-1 Advanced 6.5 VPN tunnel between CP x43-1 Advanced (VPN server) and SCALANCE M874-x using a static IP address 6.5 VPN tunnel between CP x43-1 Advanced (VPN server) and SCALANCE M874-x using a static IP address Figure 6-5 Service PC SCALANCE M874-x Automation Cell SIMATIC S7-300 or S7-400 with CP x43-1 Advanced VPN tunnel Table 6-6 CP x43-1 Advanced SCALANCE M874-x IP address public IP address for the router of the VPN server. router with port forwarding functionality (on the VPN server side). Mobile network operator's default APN (on the VPN client side). Link to the configuration description: Entry ID: , V2.1, 03/

47 Siemens AG 2017 All rights reserved 6 CP x43-1 Advanced 6.6 VPN tunnel between CP x43-1 Advanced (VPN server) and a mobile client using a static IP address 6.6 VPN tunnel between CP x43-1 Advanced (VPN server) and a mobile client using a static IP address Figure 6-6 Smartphone with IPSec Client App VPN tunnel Automation Cell SIMATIC S7-300 or S7-400 with CP x43-1 Advanced Table 6-7 CP x43-1 Advanced Mobile client IP address public IP address for the router of the VPN server. router with port forwarding functionality (on the VPN server side). Mobile network operator's default APN (on the VPN client side). Smartphone with IPSec Client app and Android operating system (on the VPN client side). Link to the configuration description: Entry ID: , V2.1, 03/

48 Siemens AG 2017 All rights reserved 7 CP 1x43-x 7 CP 1x43-x This chapter describes the configurations in which the CP 1x43-x is configured as the VPN server. This group is marked in gray. Table 7-1 CP 1x43-1 VPN remote end IP address Characteristics The firewall, VPN server and communication settings are made directly in the CP 1x43-x; the security functions are integrated in the communications processor. A static or dynamic public IP address can be used for the DSL router on the VPN server side. Entry ID: , V2.1, 03/

49 Siemens AG 2017 All rights reserved 7 CP 1x43-x 7.1 VPN tunnel between CP 1x43-1 (VPN server) and SCALANCE S using a static IP address 7.1 VPN tunnel between CP 1x43-1 (VPN server) and SCALANCE S using a static IP address Figure 7-1 Service PC Automation Cell SCALANCE S Modem/ SIMATIC S or S with CP 1x43-1 VPN tunnel Table 7-2 CP 1x43-1 SCALANCE S IP address public IP address for the router of the VPN server. router with port forwarding functionality (on the VPN server side). Standard modem, router or UMTS router, for example SCALANCE M873 (on the VPN client side). Entry ID: , V2.1, 03/

50 Siemens AG 2017 All rights reserved 7 CP 1x43-x 7.2 VPN tunnel between CP 1x43-1 (VPN server) and SCALANCE M81x-1 using a static IP address 7.2 VPN tunnel between CP 1x43-1 (VPN server) and SCALANCE M81x-1 using a static IP address Figure 7-2 Service PC SCALANCE M81x-1 Automation Cell SIMATIC S or S with CP 1x43-1 VPN tunnel Table 7-3 CP 1x43-1 SCALANCE M81x-1 IP address public IP address for the router of the VPN server. router with port forwarding functionality (on the VPN server side). Entry ID: , V2.1, 03/

51 Siemens AG 2017 All rights reserved 7 CP 1x43-x 7.3 VPN tunnel between CP 1x43-1 (VPN server) and SOFTNET Security Client using a static IP address 7.3 VPN tunnel between CP 1x43-1 (VPN server) and SOFTNET Security Client using a static IP address Figure 7-3 Service PC with SOFTNET Security Client SSC Modem/ Automation Cell SIMATIC S or S with CP 1x43-1 VPN tunnel Table 7-4 CP 1x43-1 SOFTNET Security Client IP address public IP address for the router of the VPN server. router with port forwarding functionality (on the VPN server side). Standard modem, router or UMTS router, for example SCALANCE M873 (on the VPN client side). Link to the configuration description: Entry ID: , V2.1, 03/

52 Siemens AG 2017 All rights reserved 7 CP 1x43-x 7.4 VPN tunnel between CP 1x43-1 (VPN server) and CP x43-1 Advanced using a static IP address 7.4 VPN tunnel between CP 1x43-1 (VPN server) and CP x43-1 Advanced using a static IP address Figure 7-4 Automation Cell A Automation Cell B SIMATIC S or S with CP 1x43-1 Modem/ SIMATIC S7-300 or S7-400 with CP x43-1 Advanced VPN tunnel Table 7-5 CP 1x43-1 CP x43-1 Advanced IP address public IP address for the router of the VPN server. router with port forwarding functionality (on the VPN server side). Standard modem, router or UMTS router, for example SCALANCE M873 (on the VPN client side). Link to the configuration description: In progress Entry ID: , V2.1, 03/

53 Siemens AG 2017 All rights reserved 7 CP 1x43-x 7.5 VPN tunnel between CP 1x43-1 (VPN server) and CP 1x43-1 using a static IP address 7.5 VPN tunnel between CP 1x43-1 (VPN server) and CP 1x43-1 using a static IP address Figure 7-5 Automation Cell A Automation Cell B SIMATIC S or S with CP 1x43-1 Modem/ SIMATIC S or S with CP 1x43-1 VPN tunnel Table 7-6 CP 1x43-1 CP 1x43-1 IP address public IP address for the router of the VPN server. router with port forwarding functionality (on the VPN server side). Standard modem, router or UMTS router, for example SCALANCE M873 (on the VPN client side). Link to the configuration description: Entry ID: , V2.1, 03/

54 Siemens AG 2017 All rights reserved 7 CP 1x43-x 7.6 VPN tunnel between CP 1x43-1 (VPN server) and SCALANCE M874-x using a static IP address 7.6 VPN tunnel between CP 1x43-1 (VPN server) and SCALANCE M874-x using a static IP address Figure 7-6 Service PC SCALANCE M874-x Automation Cell SIMATIC S or S with CP 1x43-1 VPN tunnel Table 7-7 CP 1x43-1 SCALANCE M874-x IP address public IP address for the router of the VPN server. router with port forwarding functionality (on the VPN server side). Mobile network operator's default APN (on the VPN client side). Entry ID: , V2.1, 03/

55 Siemens AG 2017 All rights reserved 7 CP 1x43-x 7.7 VPN tunnel between CP 1x43-1 (VPN server) and a mobile client using a static IP address 7.7 VPN tunnel between CP 1x43-1 (VPN server) and a mobile client using a static IP address Figure 7-7 Smartphone with IPSec Client App VPN tunnel Automation Cell SIMATIC S or S with CP 1x43-1 Table 7-8 CP 1x43-1 Mobile client IP address public IP address for the router of the VPN server. router with port forwarding functionality (on the VPN server side). Mobile network operator's default APN (on the VPN client side). Smartphone with IPSec Client app and Android operating system (on the VPN client side). Entry ID: , V2.1, 03/

56 Siemens AG 2017 All rights reserved 8 TS Adapter IE Advanced/ LOGO! 8 TS Adapter IE Advanced/ LOGO! This chapter describes the configurations in which the TS Adapter IE Advanced and LOGO! are configured as the VPN server. This group is marked in dark yellow. Table 8-1 TS Adapter IE Advanced VPN remote end IP address Characteristics Aside from a PC, no other hardware is required on the VPN client side to establish the VPN connection. Using the TS Adapter, either TIA Portal or the Windows SSTP client can be used as the VPN client. Using the LOGO!, the OpenVPN client must support OpenVPN V or higher Pre-Shared Key coding. Entry ID: , V2.1, 03/

57 Siemens AG 2017 All rights reserved 8 TS Adapter IE Advanced/ LOGO! 8.1 VPN tunnel between TS Adapter IE Advanced (VPN server) and Windows SSTP client using a static IP address 8.1 VPN tunnel between TS Adapter IE Advanced (VPN server) and Windows SSTP client using a static IP address Figure 8-1 Service Service PC PC Modem/ Modem/ SCALANCE TS Adapter M874-x IE Advanced Automatisierungszelle Automation Cell VPN tunnel Statische WAN-IP-Adresse VPN-Server SIMATIC S7 Stationen Stations Table 8-2 TS Adapter IE Advanced Windows SSTP client IP address public IP address for the router of the VPN server. router with port forwarding functionality (on the VPN server side). Standard modem, router or UMTS router, for example SCALANCE M873 (on the VPN client side). Windows 7 or Windows Server 2008 or higher. Link to the configuration description: Entry ID: , V2.1, 03/

58 Siemens AG 2017 All rights reserved 8 TS Adapter IE Advanced/ LOGO! 8.2 VPN tunnel between TS Adapter IE Advanced (VPN server) and TIA Portal using a static IP address 8.2 VPN tunnel between TS Adapter IE Advanced (VPN server) and TIA Portal using a static IP address Figure 8-2 Service PC TIA Portal Modem/ TS Adapter IE Advanced Automation Cell VPN tunnel SIMATIC S7 Stations Table 8-3 TS Adapter IE Advanced TIA Portal IP address public IP address for the router of the VPN server. router with port forwarding functionality (on the VPN server side). Standard modem, router or UMTS router, for example SCALANCE M873 (on the VPN client side). TIA Portal V12 SP1 or higher. Link to the configuration description: Entry ID: , V2.1, 03/

59 Siemens AG 2017 All rights reserved 8 TS Adapter IE Advanced/ LOGO! 8.3 VPN tunnel between LOGO! (VPN server) and a PC using a static IP address 8.3 VPN tunnel between LOGO! (VPN server) and a PC using a static IP address Figure 8-3 Service PC WAN LOGO! CMR with LOGO! BM VPN client VPN Tunnel VPN server Table 8-4 LOGO! CMR OpenVPN client IP address public IP address for the SIM card of the VPN server. Standard modem, router or UMTS router, for example SCALANCE M873 (on the VPN client side). Link to the configuration description: Entry ID: , V2.1, 03/

Setting up a secure VPN Connection between SCALANCE S and SSC Using a static IP Address. SCALANCE S, SOFTNET Security Client

Setting up a secure VPN Connection between SCALANCE S and SSC Using a static IP Address. SCALANCE S, SOFTNET Security Client Configuration Example 09/2014 Setting up a secure VPN Connection between SCALANCE S and SSC Using a static IP Address SCALANCE S, SOFTNET Security Client http://support.automation.siemens.com/ww/view/en/99681083

More information

Setting up a secure VPN connection between two SCALANCE S Modules Using a static IP Address

Setting up a secure VPN connection between two SCALANCE S Modules Using a static IP Address Configuration Example 09/2014 Setting up a secure VPN connection between two SCALANCE S Modules Using a static IP Address SCALANCE S http://support.automation.siemens.com/ww/view/en/99681360 Warranty and

More information

Setting up a secure VPN Connection between the TS Adapter IE Advanced and Windows 7

Setting up a secure VPN Connection between the TS Adapter IE Advanced and Windows 7 Configuration Example 09/2014 Setting up a secure VPN Connection between the TS Adapter IE Advanced and Windows 7 TS Adapter IE Advanced http://support.automation.siemens.com/ww/view/en/99681037 Warranty

More information

Setting up a secure VPN Connection between CP x43-1 Adv. and SOFTNET Security Client Using a static IP Address

Setting up a secure VPN Connection between CP x43-1 Adv. and SOFTNET Security Client Using a static IP Address Configuration Example 02/2015 Setting up a secure VPN Connection between CP x43-1 Adv. and SOFTNET Security Client Using a static IP Address SOFTNET Security Client, CP 343-1 Advanced, CP 443-1 Advanced

More information

https://support.industry.siemens.com/cs/ww/en/view/

https://support.industry.siemens.com/cs/ww/en/view/ NAT Variants with the SCALANCE S615 SCALANCE S615 https://support.industry.siemens.com/cs/ww/en/view/109744660 Siemens Industry Online Support Siemens AG Valuable Information All rights reserved Warranty

More information

Setting up a secure VPN Connection between a Tablet (ios), SCALANCE S615 and SINEMA Remote Connect Server. SINEMA Remote Connect, SCALANCE S615

Setting up a secure VPN Connection between a Tablet (ios), SCALANCE S615 and SINEMA Remote Connect Server. SINEMA Remote Connect, SCALANCE S615 Configuration Example 09/2015 Setting up a secure VPN Connection between a Tablet (ios), SCALANCE S615 and SINEMA Remote Connect Server SINEMA Remote Connect, SCALANCE S615 https://support.industry.siemens.com/cs/ww/en/view/109479578

More information

Setting up a secure VPN Connection between SCALANCE S and CP x43-1 Adv. Using a static IP Address. SCALANCE S, CP Advanced, CP Advanced

Setting up a secure VPN Connection between SCALANCE S and CP x43-1 Adv. Using a static IP Address. SCALANCE S, CP Advanced, CP Advanced Configuration Example 09/2014 Setting up a secure VPN Connection between SCALANCE S and CP x43-1 Adv. Using a static IP Address SCALANCE S, CP 343-1 Advanced, CP 443-1 Advanced http://support.automation.siemens.com/ww/view/en/99681025

More information

Configuration of an MRP Ring and a Topology with Two Projects

Configuration of an MRP Ring and a Topology with Two Projects Configuration Example 10/2016 Configuration of an MRP Ring and a Topology with Two Projects SCALANCE X, SIMATIC S7 https://support.industry.siemens.com/cs/ww/en/view/109741671 Warranty and Liability Warranty

More information

Setting up a secure VPN Connection between two M812-1 Using a static IP Address

Setting up a secure VPN Connection between two M812-1 Using a static IP Address Configuration Example 07/2015 Setting up a secure VPN Connection between two M812-1 Using a static IP Address SCALANCE M https://support.industry.siemens.com/cs/ww/en/view/109477919 Warranty and Liability

More information

Application example 02/2017. SIMATIC IOT2000 Connection to IBM Watson IoT Platform SIMATIC IOT2040

Application example 02/2017. SIMATIC IOT2000 Connection to IBM Watson IoT Platform SIMATIC IOT2040 Application example 02/2017 SIMATIC IOT2000 Connection to IBM Watson IoT Platform SIMATIC IOT2040 Warranty and liability Warranty and liability Note The Application Examples are not binding and do not

More information

Setting up a secure VPN Connection between SCALANCE M-800 and SSC

Setting up a secure VPN Connection between SCALANCE M-800 and SSC Configuration Example 12/2015 Setting up a secure VPN Connection between SCALANCE M-800 and SSC SCALANCE S615, SCALANCE M-800, SOFTNET Security Client https://support.industry.siemens.com/cs/ww/de/view/109481101

More information

Application example 12/2016. SIMATIC IOT2000 OPC UA Client SIMATIC IOT2020, SIMATIC IOT2040

Application example 12/2016. SIMATIC IOT2000 OPC UA Client SIMATIC IOT2020, SIMATIC IOT2040 Application example 12/2016 SIMATIC IOT2000 OPC UA Client SIMATIC IOT2020, SIMATIC IOT2040 Warranty and liability Warranty and liability Note The Application Examples are not binding and do not claim to

More information

https://support.industry.siemens.com/cs/ww/en/view/

https://support.industry.siemens.com/cs/ww/en/view/ Working with the TIA Portal Cloud Connector TIA Portal V14 SP1 https://support.industry.siemens.com/cs/ww/en/view/109747305 Siemens Industry Online Support Warranty and Liability Warranty and Liability

More information

Setting up a secure VPN Connection between SCALANCE S and M812-1 Using a static IP Address

Setting up a secure VPN Connection between SCALANCE S and M812-1 Using a static IP Address Configuration Example 09/2014 Setting up a secure VPN Connection between SCALANCE S and M812-1 Using a static IP Address SCALANCE S, SCALANCE M http://support.automation.siemens.com/ww/view/en/99681595

More information

Determination of suitable hardware for the Process Historian 2014 with the PH-HWAdvisor tool

Determination of suitable hardware for the Process Historian 2014 with the PH-HWAdvisor tool Application example 12/2016 Determination of suitable hardware for the Process Historian 2014 with the PH-HWAdvisor tool SIMATIC Process Historian 2014 https://support.industry.siemens.com/cs/ww/de/view/109740115

More information

Applications & Tools. Security Configurations in LAN and WAN (DSL) with SCALANCE S61x Modules and the Softnet Security Client. Industrial Security

Applications & Tools. Security Configurations in LAN and WAN (DSL) with SCALANCE S61x Modules and the Softnet Security Client. Industrial Security Cover Configurations in LAN and WAN (DSL) with S61x Modules and the Softnet Client Industrial Application Description March 2010 Applications & Tools Answers for industry. Industry Automation and Drives

More information

https://support.industry.siemens.com/cs/ww/en/view/

https://support.industry.siemens.com/cs/ww/en/view/ SIMOTION IT Application frame Manual 07/2017 https://support.industry.siemens.com/cs/ww/en/view/109748953 Siemens Industry Online Support Warranty and liability Warranty and liability Note The Application

More information

SINAMICS G/S: Integrating Warning and Error Messages into STEP 7 V5.x or WinCC flexible

SINAMICS G/S: Integrating Warning and Error Messages into STEP 7 V5.x or WinCC flexible Application Example 03/2017 SINAMICS G/S: Integrating Warning and Error Messages into STEP 7 V5.x or WinCC flexible https://support.industry.siemens.com/cs/ww/en/view/77467239 Warranty and Liability Warranty

More information

TeleService of a S station via mobile network

TeleService of a S station via mobile network Application Example 10/2016 TeleService of a S7-1200 station via mobile network CP 1242-7 V2, CP 1243-7 LTE, TCSB V3 https://support.industry.siemens.com/cs/ww/en/view/56720905 Warranty and Liability Warranty

More information

Configuration of an MRP ring with SIMOCODE and SIMATIC S SIMOCODE pro V PN, SIMATIC S Siemens Industry Online Support

Configuration of an MRP ring with SIMOCODE and SIMATIC S SIMOCODE pro V PN, SIMATIC S Siemens Industry Online Support Configuration of an MRP ring with SIMOCODE and SIMATIC S7-1500 SIMOCODE pro V PN, SIMATIC S7-1500 https://support.industry.siemens.com/cs/ww/en/view/109742280 Siemens Industry Online Support Siemens AG

More information

Windows firewall settings for X-Tools Server Pro. CMS X-Tools / V / CPU PN/DP. Application description 6/2016

Windows firewall settings for X-Tools Server Pro. CMS X-Tools / V / CPU PN/DP. Application description 6/2016 Application description 6/2016 Windows firewall settings for X-Tools Server Pro CMS X-Tools / V 04.03 / CPU 416-3 PN/DP https://support.industry.siemens.com/cs/ww/en/view/item_number Warranty and liability

More information

Integration of Process Historian / Information Server in a Domain

Integration of Process Historian / Information Server in a Domain Application Description 11/2016 Integration of Process Historian / Information Server in a Domain SIMATIC PCS 7 https://support.industry.siemens.com/cs/ww/de/view/66579062 Warranty and liability Warranty

More information

Comparing Libraries using the "Library Compare" Tool TIA Portal Openness / V14 SP1 https://support.industry.siemens.com/cs/ww/en/view/109749141 Siemens Industry Online Support Warranty and Liability Warranty

More information

SINAMICS G/S: Tool for transforming Warning and Error Messages in CSV format

SINAMICS G/S: Tool for transforming Warning and Error Messages in CSV format Application example 03/2017 SINAMICS G/S: Tool for transforming Warning and Error Messages in CSV format https://support.industry.siemens.com/cs/ww/en/view/77467239 Copyright Siemens AG 2017 All rights

More information

Generating the Parameters for the Modbus/TCP Communication

Generating the Parameters for the Modbus/TCP Communication Application description 10/2014 Generating the Parameters for the Modbus/TCP Communication http://support.automation.siemens.com/ww/view/en/60735352 Warranty and liability Warranty and liability Note The

More information

Multiuser Engineering in the TIA Portal

Multiuser Engineering in the TIA Portal Application Example 02/2017 Multiuser Engineering in the TIA Portal TIA Portal V14 https://support.industry.siemens.com/cs/ww/de/view/109740141 Warranty and Liability Warranty and Liability The Application

More information

Data Storage on Windows Server or NAS Hard Drives

Data Storage on Windows Server or NAS Hard Drives Application Example 03/2016 Data Storage on Windows Server or NAS Hard Drives SIMATIC HMI Comfort Panels, Sharing of Network Drives and Folders https://support.industry.siemens.com/cs/ww/en/view/92346478

More information

Position Control with SIMATIC S and SINAMICS V90 via IRT PROFINET SINAMICS V90 PROFINET. Application description 03/2016

Position Control with SIMATIC S and SINAMICS V90 via IRT PROFINET SINAMICS V90 PROFINET. Application description 03/2016 Application description 03/2016 Position Control with SIMATIC S7-1500 and SINAMICS V90 via IRT PROFINET SINAMICS V90 PROFINET https://support.industry.siemens.com/cs/ww/en/view/109739053 Warranty and liability

More information

Setting up a VPN Connection between a Tablet (ios) and the SINEMA Remote Connect Server SINEMA Remote Connect https://support.industry.siemens.com/cs/ww/en/view/109479577 Siemens Industry Online Support

More information

Check List for Programming Styleguide for S7-1200/S7-1500

Check List for Programming Styleguide for S7-1200/S7-1500 Programming Styleguide 10/2016 Check List for Programming Styleguide for S7-1200/S7-1500 TIA Portal https://support.industry.siemens.com/cs/ww/en/view/81318674 Warranty and Liability Warranty and Liability

More information

Converting Equipment module for SIMOTION Project Generator Manual - V1.0.3-07/2017 https://support.industry.siemens.com/cs/ww/en/view/109485620 Siemens Industry Online Support Warranty and liability Warranty

More information

Data Storage on Windows Server or NAS Hard Drives SIMATIC HMI Comfort Panels, Sharing of Network Drives and Folders https://support.industry.siemens.com/cs/ww/en/view/92346478 Siemens Industry Online Support

More information

https://support.industry.siemens.com/cs/ww/en/view/

https://support.industry.siemens.com/cs/ww/en/view/ Connecting SIMOCODE pro and Allen-Bradley Controller via EtherNet/IP SIMOCODE pro V EIP https://support.industry.siemens.com/cs/ww/en/view/109748968 Siemens Industry Online Support Warranty and liability

More information

X-Tools Loading Profile Files (LPF)

X-Tools Loading Profile Files (LPF) Application description 08/2016 X-Tools Loading Profile Files (LPF) CMS X-Tools / V 04.03 https://support.industry.siemens.com/cs/ww/en/view/item_number Warranty and liability Warranty and liability Note

More information

SIMATIC NET OPC Server Implementation

SIMATIC NET OPC Server Implementation Application example 05/2016 SIMATIC NET OPC Server Implementation PDI HMI@F&B https://support.industry.siemens.com/cs/ww/en/view/100744248 Warranty and liability Warranty and liability Note The Application

More information

Configuring a SINAMICS S120 with Startdrive V14 SIMATIC S7-1500 / SINAMICS S120 https://support.industry.siemens.com/cs/ww/en/view/109743270 Siemens Industry Online Support Warranty and Liability Warranty

More information

Checking of STEP 7 Programs for the Migration of S7-318 to S CPU318 Migration Check. Application description 01/2015

Checking of STEP 7 Programs for the Migration of S7-318 to S CPU318 Migration Check. Application description 01/2015 Application description 01/2015 Checking of STEP 7 Programs for the Migration of S7-318 to S7-300 http://support.automation.siemens.com/ww/view/en/22680601 Warranty and liability Warranty and liability

More information

PNDriver V2.1 Quick Start Guide for IOT2040 SIMATIC IOT

PNDriver V2.1 Quick Start Guide for IOT2040 SIMATIC IOT PNDriver V2.1 Quick Start Guide for IOT2040 SIMATIC IOT2040 https://support.industry.siemens.com/cs/ww/en/view/109761191 Warranty and liability Warranty and liability Note The Application Examples are

More information

Applikationen & Tools. Network Address Translation (NAT) and Network Port Address Translation (NAPT) SCALANCE W. Application Description July 2009

Applikationen & Tools. Network Address Translation (NAT) and Network Port Address Translation (NAPT) SCALANCE W. Application Description July 2009 Cover Sheet Network Address Translation (NAT) and Network Port Address Translation (NAPT) SCALANCE W Application Description July 2009 Applikationen & Tools Answers for industry. Warranty, Liability and

More information

Digitalization with TIA Portal: Integration of planning data from TIA Selection Tool to TIA Portal or STEP 7 V14 SP1 (TIA Portal), TIA Selection Tool https://support.industry.siemens.com/cs/ww/en/view/109748223

More information

Acyclic communication between S and V90PN via PROFINET. Application example 12/

Acyclic communication between S and V90PN via PROFINET. Application example 12/ Application example 12/20162016 Acyclic communication between S7-1500 and V90PN via PROFINET SINAMICS V90 / SIMATIC S7-1500 https://support.industry.siemens.com/cs/ww/en/view/109743977 Warranty and liability

More information

Setting up 08/2017. Setting up the SIMATIC IOT2000 SIMATIC IOT2020, SIMATIC IOT2040

Setting up 08/2017. Setting up the SIMATIC IOT2000 SIMATIC IOT2020, SIMATIC IOT2040 Setting up 08/2017 Setting up the SIMATIC IOT2000 SIMATIC IOT2020, SIMATIC IOT2040 Warranty and liability Warranty and liability Note The Application Examples are not binding and do not claim to be complete

More information

Multiuser Engineering in the TIA Portal TIA Portal V15 https://support.industry.siemens.com/cs/ww/en/view/109740141 Siemens Industry Online Support Warranty and Liability Warranty and Liability The Application

More information

Transmitting HMI data to an external monitor

Transmitting HMI data to an external monitor Application description 07/2015 Transmitting HMI data to an external monitor SINUMERIK 828D, SW 4.5 SP3 https://support.industry.siemens.com/cs/ww/en/view/109477688 Warranty and liability Warranty and

More information

OpennessScripter: Introduction TIA Portal / Openness API https://support.industry.siemens.com/cs/ww/en/view/109742322 Siemens Industry Online Support Siemens AG 2017 All rights reserved Warranty and Liability

More information

https://support.industry.siemens.com/cs/ww/en/view/

https://support.industry.siemens.com/cs/ww/en/view/ Generating the Parameters for the Modbus/TCP Communication https://support.industry.siemens.com/cs/ww/en/view/60735352 Siemens Industry Online Support Siemens AG 2016-20186 All rights reserved Warranty

More information

RAID systems within Industry

RAID systems within Industry White Paper 01/2014 RAID systems within Industry Functioning, variants and fields of application of RAID systems https://support.industry.siemens.com/cs/ww/en/view/109737064 Warranty and liability Warranty

More information

Remote networks. Easy remote access to machines and plants. Industrial Remote Communication. Edition 03/2017. Brochure. siemens.com/remote-networks

Remote networks. Easy remote access to machines and plants. Industrial Remote Communication. Edition 03/2017. Brochure. siemens.com/remote-networks Industrial Remote Communication Remote networks Easy remote access to machines and plants Brochure Edition 03/2017 siemens.com/remote-networks Many ways of connecting to remote networks Increasing bandwidths,

More information

Setting up a secure VPN Connection between CP x43-1 Adv. and M812-1 Using a static IP Address

Setting up a secure VPN Connection between CP x43-1 Adv. and M812-1 Using a static IP Address Configuration Example 02/2015 Setting up a secure VPN Connection between CP x43-1 Adv. and M812-1 Using a static IP Address CP 343-1 Advanced, CP 443-1 Advanced, SCALANCE M http://support.automation.siemens.com/ww/view/en/108910139

More information

https://support.industry.siemens.com/cs/ww/en/view/

https://support.industry.siemens.com/cs/ww/en/view/ Light control with LOGO! and HMI Panel Application example 07/2017 https://support.industry.siemens.com/cs/ww/en/view/109747758 Siemens Industry Online Support Warranty and liability Warranty and liability

More information

Function Block for Monitoring 24V Load Circuits SITOP PSE200U, STEP 7 V5.5 https://support.industry.siemens.com/cs/ww/en/view/61450284 Siemens Industry Online Support Warranty and Liability Warranty and

More information

Setting up 01/2017. Setting up the SIMATIC IOT2000 SIMATIC IOT2020, SIMATIC IOT2040

Setting up 01/2017. Setting up the SIMATIC IOT2000 SIMATIC IOT2020, SIMATIC IOT2040 Setting up 01/2017 Setting up the SIMATIC IOT2000 SIMATIC IOT2020, SIMATIC IOT2040 Warranty and liability Warranty and liability Note The Application Examples are not binding and do not claim to be complete

More information

SIMATIC PDM - Central access to MODBUS RTU devices

SIMATIC PDM - Central access to MODBUS RTU devices Application example 03/2017 SIMATIC PDM - Central access to MODBUS RTU devices Customer benefits and a step-by-step description in Engineering https://support.industry.siemens.com/cs/ww/en/view/109740107

More information

Automatic Visualization of the Sample Blocks in WinCC Advanced

Automatic Visualization of the Sample Blocks in WinCC Advanced Application Example 11/2016 Automatic Visualization of the Sample Blocks in WinCC Advanced SiVArc, WinCC Advanced https://support.industry.siemens.com/cs/ww/de/view/66839614 Warranty and Liability Warranty

More information

Setting up time synchronization of Process Historian and Information Server

Setting up time synchronization of Process Historian and Information Server Application example 11/2015 Setting up time synchronization of Process Historian and Information Server SIMATIC PCS 7 V8.1 https://support.industry.siemens.com/cs/ww/en/view/66579062 Warranty and Liability

More information

https://support.industry.siemens.com/cs/ww/en/view/

https://support.industry.siemens.com/cs/ww/en/view/ Runtime Measurement using SIMATIC S7-1500 Profiling V1.0.2 https://support.industry.siemens.com/cs/ww/en/view/109750245 Siemens Industry Online Support Siemens AG 2017 All rights reserved Warranty and

More information

APF report templates based on data from the WinCC User Archive

APF report templates based on data from the WinCC User Archive Application example 03/2017 APF report templates based on data from the WinCC User Archive PCS 7, Information Server https://support.industry.siemens.com/cs/ww/en/view/64906050 Warranty and liability Warranty

More information

https://support.industry.siemens.com/cs/ww/en/view/

https://support.industry.siemens.com/cs/ww/en/view/ : Connecting Simulink Models to SIMATIC PLCSIM Advanced via OPC UA SIMATIC S7-PLCSIM Advanced Simulink https://support.industry.siemens.com/cs/ww/en/view/109749187 Siemens Industry Online Support Warranty

More information

User Login with RFID Card Reader WinCC Advanced V14 SP1, SIMATIC IPC https://support.industry.siemens.com/cs/ww/de/view/99808171 Siemens Industry Online Support Warranty and Liability Warranty and Liability

More information

Communication between HMI and Frequency Converter. Basic Panel, Comfort Panel, Runtime Advanced, SINAMICS G120. Application Example 04/2016

Communication between HMI and Frequency Converter. Basic Panel, Comfort Panel, Runtime Advanced, SINAMICS G120. Application Example 04/2016 Application Example 04/2016 Communication between HMI and Frequency Converter Basic Panel, Comfort Panel, Runtime Advanced, SINAMICS G120 https://support.industry.siemens.com/cs/ww/en/view/109481157 Warranty

More information

Guideline for Library Handling in TIA Portal TIA Portal V14 SP1 https://support.industry.siemens.com/cs/ww/en/view/109747503 Siemens Industry Online Support Siemens AG 2017 All rights reserved Warranty

More information

Library Description 08/2015. HMI Templates. TIA Portal WinCC V13. https://support.industry.siemens.com/cs/ww/en/view/

Library Description 08/2015. HMI Templates. TIA Portal WinCC V13. https://support.industry.siemens.com/cs/ww/en/view/ Library Description 08/2015 TIA Portal WinCC V13 https://support.industry.siemens.com/cs/ww/en/view/91174767 Warranty and Liability Warranty and Liability Note The Application Examples are not binding

More information

SIMATIC Energy Suite Visualization example of the "*.csv"-energy Data Files

SIMATIC Energy Suite Visualization example of the *.csv-energy Data Files Application Example 03/2017 SIMATIC Energy Suite Visualization example of the "*.csv"-energy Data Files SIMATIC STEP 7 (TIA Portal), SIMATIC Energy Suite https://support.industry.siemens.com/cs/ww/en/view/109739772

More information

Migration of a Process Historian database

Migration of a Process Historian database Application Example 03/2017 Migration of a Process Historian database SIMATIC PCS 7 https://support.industry.siemens.com/cs/ww/en/view/66579062 Warranty and liability Warranty and liability Note The Application

More information

Display of SINAMICS Fault Messages in WinCC V7.4

Display of SINAMICS Fault Messages in WinCC V7.4 Application Example 03/2017 Display of SINAMICS Fault Messages in WinCC V7.4 SINAMICS G120, WinCC V7.4 https://support.industry.siemens.com/cs/ww/de/view/109744939 Warranty and Liability Warranty and Liability

More information

Display of SINAMICS Error Messages in Runtime Professional

Display of SINAMICS Error Messages in Runtime Professional Application Example 09/2016 Display of SINAMICS Error Messages in Runtime Professional SINAMICS G120, WinCC Runtime Professional https://support.industry.siemens.com/cs/ww/en/view/109738320 Warranty and

More information

Segmenting a Network Using s SCALANCE X https://support.industry.siemens.com/cs/ww/en/view/109749844 Siemens Industry Online Support Siemens AG 2017 All rights reserved Warranty and Liability Warranty

More information

Acknowledgement of WinCC Messages with forced comments WinCC V7 https://support.industry.siemens.com/cs/ww/en/view/52329908 Siemens Industry Online Support Warranty and liability Warranty and liability

More information

Networking a SINUMERIK 828D

Networking a SINUMERIK 828D Application description 06/2015 828D SINUMERIK 828D, SW 4.5 SP3 https://support.industry.siemens.com/cs/ww/en/view/109474567 Warranty and liability Warranty and liability Note The Application Examples

More information

Exchange of large data volumes between S control system and WinCC

Exchange of large data volumes between S control system and WinCC Application Example 09/2016 Exchange of large data volumes between S7-1500 control system and WinCC S7-1500, WinCC V7.4 https://support.industry.siemens.com/cs/ww/de/view/37873547 Warranty and Liability

More information

Improving the performance of the Process Historian

Improving the performance of the Process Historian Application example 01/2016 Improving the performance of the Process Historian SIMATIC PCS 7 https://support.industry.siemens.com/cs/ww/en/view/66579062 Warranty and Liability Warranty and Liability Note

More information

House Control with Touch Panel

House Control with Touch Panel Application Example 04/2016 House Control with Touch Panel LOGO! 8, KTP700 Set 10 https://support.industry.siemens.com/cs/ww/en/view/68585344 Warranty and liability Warranty and liability Note The Application

More information

Restarting Windows at the SIMATIC S7-1500 Software Controller Software Controller V 2.1, TIA Portal V14 SP1 https://support.industry.siemens.com/cs/ww/en/view/109748679 Siemens Industry Online Support

More information

Moving a Process Historian/ Information Server from Workgroup A to Workgroup B

Moving a Process Historian/ Information Server from Workgroup A to Workgroup B Application description 03/2014 Moving a Process Historian/ Information Server from Workgroup A to Workgroup B SIMATIC PCS 7 V8.0 SP1 Upd1 http://support.automation.siemens.com/ww/view/en/66579062 Warranty

More information

Fail-Safe Group Shutdown of the ET 200SP F-Motor Starter with F-DQ SIMATIC Safety Integrated https://support.industry.siemens.com/cs/ww/en/view/109748128 Siemens Industry Online Support Warranty and Liability

More information

https://support.industry.siemens.com/cs/ww/en/view/

https://support.industry.siemens.com/cs/ww/en/view/ Configuration Change with SINEMA Server for Network Devices with Command Line Interface (CLI) SINEMA Server V13 / V14 https://support.industry.siemens.com/cs/ww/en/view/109749379 Siemens Industry Online

More information

Application for Process Automation

Application for Process Automation Application for Process Automation Connecting external periphery to PCS 7 via IE/PB Link PN IO Application Note Warranty, liability and support Note The Application Examples are not binding and do not

More information

Key Panel Library / TIA Portal

Key Panel Library / TIA Portal Application Example 06/2015 Key Panel Library / TIA Portal Configuration Manual https://support.industry.siemens.com/cs/ww/en/63482149 Warranty and Liability Warranty and Liability Note The application

More information

STEP 7 function block to control a MICROMASTER 4 or SINAMICS G120/G120D via PROFIBUS DP

STEP 7 function block to control a MICROMASTER 4 or SINAMICS G120/G120D via PROFIBUS DP Application description 01/2014 STEP 7 function block to control a MICROMASTER 4 or SINAMICS G120/G120D via PROFIBUS DP Function / application of the FB14 in a SIMATIC S7-300/400 in STEP 7V5.x http://support.automation.siemens.com/ww/view/en/22078757

More information

Setting up VPN connection between two SCALANCE SC SCALANCE SC https://support.industry.siemens.com/cs/ww/en/view/99681360 Siemens Industry Online Support Siemens AG 2018 All rights reserved Legal information

More information

Sending and Receiving SMS Messages via a SCALANCE M Router SCALANCE M874/M876, S7-1200/S CPU / V1.0. Application Example 06/2016

Sending and Receiving SMS Messages via a SCALANCE M Router SCALANCE M874/M876, S7-1200/S CPU / V1.0. Application Example 06/2016 Application Example 06/2016 Sending and Receiving SMS Messages via a SCALANCE M Router SCALANCE M874/M876, S7-1200/S7-1500 CPU / V1.0 https://support.industry.siemens.com/cs/ww/en/view/54361177 Warranty

More information

Visualizing Energy Data of a SITOP PSU8600

Visualizing Energy Data of a SITOP PSU8600 Application Example 02/2017 Visualizing Energy Data of a SITOP PSU8600 SIMATIC STEP 7 Professional V14, WinCC Comfort / Advanced V14, SITOP PSU8600, SIMATIC S7-1500 https://support.industry.siemens.com/cs/ww/en/view/109738082

More information

PCS 7 Process Visualization on Mobile Devices with RDP

PCS 7 Process Visualization on Mobile Devices with RDP i Application Example 04/2016 on Mobile Devices with RDP SIMATIC PCS 7 V8.1 https://support.industry.siemens.com/cs/ww/en/view/102843424 Warranty and Liability Warranty and Liability Note The Application

More information

Cover. WinAC Command. User documentation. V1.5 November Applikationen & Tools. Answers for industry.

Cover. WinAC Command. User documentation. V1.5 November Applikationen & Tools. Answers for industry. Cover WinAC Command User documentation V1.5 November 2009 Applikationen & Tools Answers for industry. Industry Automation and Drives Technologies Service & Support Portal This article is taken from the

More information

User Login with RFID Card Reader

User Login with RFID Card Reader Application Description 10/2014 User Login with RFID Card Reader Basic Panels / Comfort Panels / WinCC V13 http://support.automation.siemens.com/ww/view/en/99808171 Warranty and Liability Warranty and

More information

SIMATIC PCS 7 Minimal Configuration

SIMATIC PCS 7 Minimal Configuration Application description 05/2015 SIMATIC PCS 7 Minimal Configuration SIMATIC PCS 7 V8.1 https://support.industry.siemens.com/cs/ww/en/view/24023824 Warranty and liability Warranty and liability Note The

More information

Connection of SIMATIC Energy Suite to SIMATIC Energy Manager PRO and subsequent Reporting SIMATIC Energy Manager PRO V7.0, SIMATIC Energy Suite V14 SP1 https://support.industry.siemens.com/cs/ww/en/view/109744400

More information

I-Device Function in Standard PN Communication SIMATIC S7-CPU, CP, SIMOTION, SINUMERIK. Configuration Example 08/2015

I-Device Function in Standard PN Communication SIMATIC S7-CPU, CP, SIMOTION, SINUMERIK. Configuration Example 08/2015 Configuration Example 08/2015 Function in Standard PN Communication SIMATIC S7-CPU, CP, SIMOTION, SINUMERIK https://support.industry.siemens.com/cs/ww/en/view/109478798 Siemens AG 2015 All rights reserved

More information

Integration of SIMATIC PCS 7 Asset Management into existing projects

Integration of SIMATIC PCS 7 Asset Management into existing projects Application Example 10/2010 Integration of SIMATIC PCS 7 Asset Management into existing projects SIMATIC PCS 7 https://support.industry.siemens.com/cs/ww/en/view/27833758 Warranty and liability Warranty

More information

X-Tools configuration to connect with OPC servers and clients

X-Tools configuration to connect with OPC servers and clients Application description 6/2016 X-Tools configuration to connect with OPC servers and clients CMS X-Tools / V 04.03 https://support.industry.siemens.com/cs/ww/en/view/item_number Warranty and liability

More information

Calculating the expected PH storage requirements of SIMATIC BATCH batches

Calculating the expected PH storage requirements of SIMATIC BATCH batches Application Example 08/2016 Calculating the expected PH storage requirements of SIMATIC BATCH batches SIMATIC Process Historian (PH) https://support.industry.siemens.com/cs/ww/en/view/66579062 Siemens

More information

Configuring the F-I-Device function with the SENDDP and RCVDP blocks.

Configuring the F-I-Device function with the SENDDP and RCVDP blocks. Configuration Example 11/2016 Configuring the F-I-Device function with the SENDDP and RCVDP blocks. PROFIsafe https://support.industry.siemens.com/cs/ww/de/view/109478798 Warranty and Liability Warranty

More information

SINAMICS V: Speed Control of a V20 with S (TIA Portal) via MODBUS RTU, with HMI

SINAMICS V: Speed Control of a V20 with S (TIA Portal) via MODBUS RTU, with HMI Short Documentation 11/2014 SINAMICS V: Speed Control of a V20 with S7-1200 (TIA Portal) via MODBUS RTU, with HMI SINAMICS V20, SIMATIC S7-1200 http://support.automation.siemens.com/ww/view/en/63696870

More information

STEP 7 Professional V14 SP1, Energy Suite V14 SP1, SENTRON PAC Measuring Devices, Modbus TCP

STEP 7 Professional V14 SP1, Energy Suite V14 SP1, SENTRON PAC Measuring Devices, Modbus TCP Block for Connecting Modbus TCP Devices to Energy Suite V14 SP1 STEP 7 Professional V14 SP1, Energy Suite V14 SP1, SENTRON PAC Measuring Devices, Modbus TCP https://support.industry.siemens.com/cs/ww/en/view/109749074

More information

https://support.industry.siemens.com/cs/ww/en/view/

https://support.industry.siemens.com/cs/ww/en/view/ Fail-Safe Group Shutdown of the ET 200SP F-Motor Starter with F-PM-E SIMATIC Safety Integrated https://support.industry.siemens.com/cs/ww/en/view/109748128 Siemens Industry Online Support Warranty and

More information

TeleService of a S7-1200 station via mobile network CP 1242-7 V2, CP 1243-7 LTE, TCSB V3.1 https://support.industry.siemens.com/cs/ww/en/view/56720905 Siemens Industry Online Support Legal information

More information

Plant Data Interface for the Food & Beverage Industry in SIMATIC PCS 7. Interface description based on Weihenstephan Standards

Plant Data Interface for the Food & Beverage Industry in SIMATIC PCS 7. Interface description based on Weihenstephan Standards Application example 05/2016 Plant Data Interface for the Food & Beverage Industry in SIMATIC PCS 7 Interface description based on Weihenstephan Standards https://support.industry.siemens.com/cs/ww/en/view/109483798

More information

Getting Started Understanding and Using SINEMA Server V14 SINEMA Server https://support.industry.siemens.com/cs/ww/en/view/109746780 Siemens Industry Online Support Siemens AG 2017 All rights reserved

More information

Application on Control Technology

Application on Control Technology Application on Control Technology Programming example in Ladder Logic (SSL) to determine a battery fault Warranty, liability and support Note The application examples are not binding and do not claim to

More information

Engineering of the Configuration Control for IO Systems

Engineering of the Configuration Control for IO Systems pplication Example 03/2017 Engineering of the Configuration Control for IO Systems ET 200SP, ReconfigIOSystem https://support.industry.siemens.com/cs/ww/en/view/29430270 Siemens G 2016 ll rights reserved

More information